Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.670
Filtrar
1.
Proc Biol Sci ; 291(2026): 20240820, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38981526

RESUMO

Unravelling the functional steps that underlie major transitions in the fossil record is a significant challenge for biologists owing to the difficulties of interpreting functional capabilities of extinct organisms. New computational modelling approaches provide exciting avenues for testing function in the fossil record. Here, we conduct digital bending experiments to reconstruct vertebral function in non-mammalian synapsids, the extinct forerunners of mammals, to provide insights into the functional underpinnings of the synapsid-mammal transition. We estimate range of motion and stiffness of intervertebral joints in eight non-mammalian synapsid species alongside a comparative sample of extant tetrapods, including salamanders, reptiles and mammals. We show that several key aspects of mammalian vertebral function evolved outside crown Mammalia. Compared to early diverging non-mammalian synapsids, cynodonts stabilized the posterior trunk against lateroflexion, while evolving axial rotation in the anterior trunk. This was later accompanied by posterior sagittal bending in crown mammals, and perhaps even therians specifically. Our data also support the prior hypothesis that functional diversification of the mammalian trunk occurred via co-option of existing morphological regions in response to changing selective demands. Thus, multiple functional and evolutionary steps underlie the origin of remarkable complexity in the mammalian backbone.


Assuntos
Evolução Biológica , Fósseis , Mamíferos , Coluna Vertebral , Animais , Mamíferos/fisiologia , Fósseis/anatomia & histologia , Coluna Vertebral/anatomia & histologia , Coluna Vertebral/fisiologia , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Répteis/fisiologia , Répteis/anatomia & histologia
2.
Sensors (Basel) ; 24(13)2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-39001168

RESUMO

This study examines the impact of axial clearance variations on the performance characteristics of a dual-rotor flowmeter (DRT-FM) through numerical simulations, with the validity of the numerical results verified by calibration experiments. The results indicate that within the range of 200 L/h to 1600 L/h, the K factors of different groups increase as clearance increases. The K factor of the 0.80 mm group is the largest, showing an average increase of around 6% compared to that of the 0.50 mm group. Additionally, Linearity E also decreased, with a minimum of 1.07% in the 0.65 mm group, significantly lower than the 3.33% in the 0.50 mm group. Furthermore, the pressure loss increased slightly, with the 0.65 mm group having the largest pressure loss; however, at a flow rate of 1600 L/h, the pressure loss only increases by 0.186 kPa compared to that of the 0.50 mm group. Flow field analysis reveals that changes in axial clearance predominantly affect pressure distribution. Larger clearances reduce low-pressure regions on upstream and downstream transition surfaces, thereby reducing energy loss due to pressure changes. Entropy analysis further demonstrates that higher axial clearance decreases energy loss in the upstream and downstream stationary domains, optimizing the DRT-FM's energy characteristics.

3.
RMD Open ; 10(3)2024 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-39004432

RESUMO

BACKGROUND: The Assessment of SpondyloArthritis international Society-European Alliance of Associations for Rheumatology recommendations for axial spondyloarthritis (axSpA) management include patient assessment for biological disease-modifying antirheumatic drug (bDMARD) treatment response after at least 12 weeks of treatment. The current treat-to-target strategy for axSpA is to achieve inactive disease (ID; Axial Spondyloarthritis Disease Activity Score (ASDAS) <1.3) or at least low disease activity (LDA; 1.3≤ASDAS<2.1).To investigate the association between treatment response at week 12 and/or week 24 and attainment of the ASDAS<2.1 treat-to-target recommendation at week 52 in bDMARD-naïve patients with radiographic (r-)axSpA treated with ixekizumab (IXE). METHODS: This post hoc analysis included patients randomly assigned to IXE 80 mg every 4 weeks from COAST-V (NCT02696785), a phase 3 trial in bDMARD-naïve patients with r-axSpA. The proportion of patients who achieved ASDAS<2.1 at week 52 was measured among those who attained or not clinically important improvement (CII, ∆ASDAS≥1.1) response, and among those with ID, LDA and high or very high disease activity at week 12 and/or week 24. Non-response was assumed for missing data. RESULTS: Amongst 81 patients, 47 (58.0%) achieved ASDAS CII at week 12, with 70.2% (n=33) achieving ASDAS<2.1 at week 52. At week 24, 52 (64.2%) patients achieved ASDAS CII, with 71.2% (n=37) achieving ASDAS<2.1 at week 52. Of the 24 patients who did not achieve ASDAS CII at either week 12 or week 24, 5 (20.8%) achieved ASDAS<2.1 at week 52. CONCLUSION: This analysis reinforces the current recommendation that continuing treatment in those achieving ASDAS CII at week 12 and/or week 24 increases the likelihood of obtaining ID/LDA at week 52. TRIAL REGISTRATION NUMBER: NCT02696785.


Assuntos
Anticorpos Monoclonais Humanizados , Espondiloartrite Axial , Humanos , Anticorpos Monoclonais Humanizados/uso terapêutico , Anticorpos Monoclonais Humanizados/administração & dosagem , Feminino , Masculino , Resultado do Tratamento , Adulto , Pessoa de Meia-Idade , Espondiloartrite Axial/tratamento farmacológico , Espondiloartrite Axial/etiologia , Antirreumáticos/uso terapêutico , Antirreumáticos/administração & dosagem , Índice de Gravidade de Doença , Radiografia
4.
Photodiagnosis Photodyn Ther ; : 104267, 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39009205

RESUMO

OBJECTIVE: To evaluate the effectiveness of low-level red light (LRL) in controlling the progression of myopia in children and adolescents. METHODS: A randomized controlled trial was conducted from March 2022 to June 2022 at the Xuzhou First People's Hospital. A total of 73 children and adolescents with myopia, between the ages of 6 and 14, and meeting the inclusion criteria, were randomly divided into two groups. The experimental group wore single vision spectacles with LRL intervention, while the control group wore single vision spectacles alone. Spherical equivalent refraction (SER), axial length (AL), subfoveal choroidal thickness (SFCT), and best-corrected visual acuity (BCVA) were measured for the participants. Data analysis was performed using chi-square test, independent samples t-test, and Mann-Whitney U test. To compare the changes in SER and AL between groups, we utilized the Generalized Estimating Equations (GEE) model. RESULTS: The experimental group was composed of 36 individuals, while the control group had 37. The mean age of the participants was 8.9 ± 2.0 years. No statistically significant distinctions in SER, AL and SFCT were observed between the two groups at baseline (P > 0.05). After 6 months of intervention, the experimental group's increase in SER (-0.01D; 95% CI: -0.09, 0.06) was higher than that of the control group (-0.41D; 95% CI: -0.51, -0.32), with a significance level of P < 0.001. Furthermore, the changes over time revealed significant differences between the two groups (Wald χ2group×time: 31.576, P < 0.001). The experimental group's AL increase (-0.02mm; 95% CI: -0.07, 0.03) was less than the control group's (0.22mm; 95% CI: 0.19, 0.25) (P < 0.001), with a significant difference over time between them (wald χ2group×time: 62.305, P < 0.001). SFCT change after 6 months in the experimental group was significantly greater (29.19µm; 95% CI: 18.48, 39.91) compared to that of the control group (-6.59µm; 95% CI: -14.28, 1.09) (P < 0.001). No adverse events were observed, and there was no evidence of fundus structural damage on OCT imaging. CONCLUSIONS: The findings suggest that low-level red light can effectively control myopia progression in children and adolescents within 6 months. No adverse reactions were observed.

5.
Adv Sci (Weinh) ; : e2307254, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38946659

RESUMO

The rational construction of efficient hypoxia-tolerant nanocatalysts capable of generating singlet oxygen (1O2) without external stimuli is of great importance for tumor therapy. Herein, uniformly dispersed and favorable biosafety profile graphitic carbon nitride quantum dots immobilized with Fe-N4 moieties modulated by axial O atom (denoted as O-Fe-N4) are developed for converting H2O2 into 1O2 via Russell reaction, without introducing external energy. Notably, O-Fe-N4 performs two interconnected catalytic properties: glutathione oxidase-mimic activity to provide substrate for subsequent 1O2 generation, avoiding the blunting anticancer efficacy by glutathione. The O-Fe-N4 catalyst demonstrates a specific activity of 79.58 U mg-1 at pH 6.2, outperforming the most reported Fe-N4 catalysts. Density functional theory calculations demonstrate that the axial O atom can effectively modulate the relative position and electron affinity between Fe and N, lowering the activation energy, strengthening the selectivity, and thus facilitating the Russell-type reaction. The gratifying enzymatic activity stemming from the well-defined Fe-N/O structure can inhibit tumor proliferation by efficiently downregulating glutathione peroxidase 4 activity and inducing lipid peroxidation. Altogether, the O-Fe-N4 catalyst not only represents an efficient platform for self-cascaded catalysis to address the limitations of 1O2-involved cancer treatment but also provides a paradigm to enhance the performance of the Fe-N4 catalyst.

6.
Cureus ; 16(5): e61441, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38947656

RESUMO

Axial spondyloarthritis (SpA) is a chronic inflammatory condition predominantly affecting the sacroiliac joints and spine, typically presenting before the age of 45 years with inflammatory back pain. However, diagnostic challenges arise when atypical features and negative autoimmune markers obscure the clinical picture. We present a case of a male in his 40s with no significant medical history, presenting with a three-month history of inflammatory back pain. Despite negative human leukocyte antigen B27 (HLA-B27) status, clinical examination, including positive findings on the FABER (flexion, abduction, and external rotation) test and exaggerated muscle tenderness, raised suspicion of axial SpA. An MRI of the pelvis confirmed bilateral symmetrical sacroiliitis, supporting the diagnosis. Unexpectedly, further investigations revealed a very low vitamin D level, normal calcium levels, and elevated parathyroid hormone (PTH), suggesting secondary hyperparathyroidism. A subsequent PET scan disclosed increased uptake posterior to the right lobe of the thyroid, prompting consideration of secondary hyperparathyroidism due to severe vitamin D deficiency. Treatment with vitamin D supplementation and nonsteroidal anti-inflammatory drugs yielded remarkable improvement in symptoms, with normal repeat blood investigations post-treatment. This case underscores the importance of a comprehensive diagnostic approach in patients with inflammatory back pain, especially when classical markers such as HLA-B27 are negative. It highlights the potential interplay between axial SpA and secondary hyperparathyroidism, emphasizing the need for vigilance and interdisciplinary collaboration in clinical practice.

7.
Musculoskeletal Care ; 22(3): e1916, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38988196

RESUMO

OBJECTIVE: The Internet has transformed how patients access health information. We examined Google search engine data to understand which aspects of health are most often searched for in combination with inflammatory arthritis (IA). METHODS: Using Google Trends data (2011-2022) we determined the relative popularity of searches for 'patient symptoms' (pain, fatigue, stiffness, mood, work) and 'treat-to-target' (disease-modifying drugs, steroids, swelling, inflammation) health domains made with rheumatoid arthritis (RA), psoriatic arthritis (PsA), and axial spondyloarthritis (AxSpA) in the UK/USA. Google Trends normalises searches by popularity over time and region, generating 0-100 scale relative search volumes (RSV; 100 represents the time-point with most searches). Up to five search term combinations can be compared. RESULTS: In all IA forms, pain was the most popular patient symptom domain. UK/USA searches for pain gave mean RSVs of 58/79, 34/51, and 39/63 with RA, PsA, and AxSpA; mean UK/USA RSVs for other patient symptom domains ranged 2-7/2-8. Methotrexate was the most popular treat-to-target search term with RA/PsA in the UK (mean 28/21) and USA (mean 63/33). For AxSpA, inflammation was most popular (mean UK/USA 9/34). Searches for pain were substantially more popular than searches for methotrexate in RA and PsA, and inflammation in AxSpA. Searches increased over time. CONCLUSIONS: Pain is the most popular search term used with IA in Google searches in the UK/USA, supporting surveys/qualitative studies highlighting the importance of improving pain to patients with IA. Routine pain assessments should be embedded within treat-to-target strategies to ensure patient perspectives are considered.


Assuntos
Artrite Reumatoide , Internet , Ferramenta de Busca , Humanos , Ferramenta de Busca/estatística & dados numéricos , Reino Unido , Artrite Reumatoide/tratamento farmacológico , Artrite Psoriásica/tratamento farmacológico , Estados Unidos , Comportamento de Busca de Informação
8.
Artigo em Inglês | MEDLINE | ID: mdl-38989808

RESUMO

PURPOSE: To investigate axial elongation (AE) and changes in relative peripheral refraction (RPR) in anisomyopic children undergoing orthokeratology (ortho-k). METHODS: Bilateral anisomyopic children, 7-12 years of age, were treated with ortho-k. Axial length (AL) and RPR, from 30° nasal (N30°) to 30° temporal (T30°), were measured at baseline and every 6 months over the study period. AE, changes in RPR and changes in the interocular AL difference were determined over time. RESULTS: Twenty-six of the 33 subjects completed the 2-year study. The AE of the higher myopic (HM) eyes (at least 1.50 D more myopia than the other eye) (0.26 ± 0.29 mm) was significantly smaller than for the less myopic (LM) eyes (0.50 ± 0.27 mm; p = 0.003), leading to a reduction in the interocular difference in AL (p = 0.001). Baseline RPR measurements in the HM eyes were relatively more hyperopic at T30°, N20° and N30° (p ≤ 0.02) and greater myopic shifts were observed at T20° (p < 0.001), T30° (p < 0.001), N20° (p = 0.02) and N30° (p = 0.01) after lens wear. After 2 years of ortho-k lens wear, temporal-nasal asymmetry increased significantly, being more myopic at the temporal locations in both eyes (p < 0.001), while AE was associated with the change in RPR at N20° (ß = 0.134, p = 0.01). The interocular difference in AE was also positively associated with the interocular difference in RPR change at N30° (ß = 0.111, p = 0.02). CONCLUSIONS: Ortho-k slowed AE in bilateral anisomyopia, with slower growth in the HM eyes leading to a reduction in interocular AL differences. After ortho-k, RPR changed from hyperopia to myopia, with greater changes induced in the HM eyes, and slower AE was associated with a more myopic shift in RPR, especially in the nasal field of both eyes.

9.
Chemistry ; : e202402201, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39008613

RESUMO

Asymmetric kinetic resolution polymerization (AKRP) provides an ideal way to obtain highly isotactic polylactide (PLA) with superior thermal-mechanical properties from racemic lactide (rac-LA). However, the development of a new catalytic system with concurrent high activity and selectivity at ambient temperature remains a great challenge. Here, a series of simple and effective binary organocatalytic pairs containing axial-chiral thioureas and commercially available phosphazene bases were designed. These chiral binary organocatalytic pairs allow for both high polymerization activity and moderate enantioselectivity for AKRP of rac-LA at room temperature, yielding semi-crystalline and metal-free stereoblock PLA with a melting temperature as high as 186 °C. The highest kinetic resolution coefficient (krel) of 8.5 at 47% conversion was obtained, and D-LA was preferentially polymerized via kinetic resolution with a maximum selectivity factor (kD/kL) of 18.1, indicating that an enantiomorphic site control mechanism (ESC) was involved.

10.
BMC Ophthalmol ; 24(1): 286, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39009984

RESUMO

BACKGROUND: To compare the surgical outcomes of the inverted internal limiting membrane (ILM) flap technique and ILM insertion for macular hole (MH) without retinal detachment in eyes with extremely high myopia. METHODS: In this retrospective study, we analyzed 22 eyes with an axial length ≥ 30.0 mm that had underwent MH surgery between April 2015 and August 2021. The surgical procedures involved either an inverted ILM flap or ILM insertion. The outcomes were compared between the two techniques. Closure of the MH was confirmed by optical coherence tomography (OCT). The best-corrected visual acuity (BCVA) was measured before and after surgery. Associated complications were documented. RESULTS: The median of axial length was 30.64 mm (range, 30.0-34.42). The MH closed in 100% (22/22) eyes and did not recur with a median follow-up of 12.5 months. For the inverted ILM flap technique, the median BCVA improved significantly from 0.80 logarithm of the minimum angle of resolution (logMAR) (range, 0.40-2.00) before surgery to 0.70 logMAR (range, 0.09-1.52) after surgery (p = 0.002). In addition, the median of final BCVA was better for the inverted ILM flap than ILM insertion (0.7 logMAR V.S. 1.00 logMAR; p = 0.016). CONCLUSIONS: In eyes with extremely high myopia, despite comparable effects on MH closure for both ILM insertion and the inverted ILM flap, the later technique achieved significantly better visual outcomes.


Assuntos
Membrana Basal , Miopia Degenerativa , Perfurações Retinianas , Retalhos Cirúrgicos , Tomografia de Coerência Óptica , Acuidade Visual , Vitrectomia , Humanos , Perfurações Retinianas/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Tomografia de Coerência Óptica/métodos , Vitrectomia/métodos , Membrana Basal/cirurgia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Miopia Degenerativa/fisiopatologia , Idoso , Adulto , Seguimentos
11.
Front Med (Lausanne) ; 11: 1425449, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38966536

RESUMO

Introduction: This study aims to describe the clinical characteristics, disease activity, and structural damage in patients with axial spondyloarthritis (axSpA) who receive chronic treatment with nonsteroideal anti-inflammatory drugs (NSAIDs) or advanced therapies in a clinical setting. Methods: Cross-sectional study on axSpA patients consecutively recruited from the outpatient clinic of a tertiary hospital. We collected data on clinical and demographic characteristics, as well as treatment patterns involving NSAIDs and advanced therapies. Structural damage was assessed using mSASSS. Results: Overall, data from 193 axSpA patients (83% ankylosing spondylitis) were gathered, with a mean disease duration of 21.4 years. Of these, 85 patients (44%) were exclusively taking NSAIDs, while 108 (56%) were receiving advanced therapies, with TNF inhibitors being the predominant choice (93 out of 108, 86.1%). Among patients using NSAIDs, 64.7% followed an on-demand dosing regimen, while only 17.6% used full doses. Disease activity was low, with a mean BASDAI of 3.1 and a mean ASDAS-CRP of 1.8. In comparison to patients under chronic NSAID treatment, those taking advanced therapies were primarily male (69.4% versus 51.8%, p = 0.025) and significantly younger (mean age of 49 versus 53.9 years, p = 0.033). Additionally, patients on advanced therapies exhibited lower ASDAS-CRP (p = 0.046), although CRP serum levels and BASDAI scores did not differ between the two groups. In the multivariable analysis, therapy (NSAID versus biological treatment) was not independently associated with ASDAS-CRP, BASDAI or mSASSS. Conclusion: This cross-sectional analysis of a real-world cohort of axSpA patients shows positive clinical and radiological outcomes for both NSAIDs and advanced therapies.

13.
Cont Lens Anterior Eye ; : 102256, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38965001

RESUMO

PURPOSE: To examine the safety and efficacy of soft multifocal contact lenses on slowing the rate of myopia progression. METHODS: A prospective, randomized, double-masked clinical trial was conducted including 115 children (55 boys and 60 girls) aged 8 to 15 years. Children were assigned to wear one of two daily disposable soft contact lens designs; a multifocal design (Pegavision) or a dual-focus design (MiSight, Coopervision) in both eyes for at least 8 h per day for one year. All contact lenses were replaced on a daily basis. Measurements were obtained using a logMAR vision meter, including objective refraction, handheld retinoscopy, high (96 %) and low (12 %) contrast sensitivity, and distance and near visual acuity. Axial length was measured every 6 months. RESULTS: After one year, the spherical equivalent refractive error and axial length of the experimental group (Pegavision) increased by -0.50 ± 0.48 D and 0.24 ± 0.16 mm, respectively, in the right eye and -0.47 ± 0.37 D and 0.23 ± 0.16 mm, respectively, in the left eye. The spherical equivalent refractive error and axial length of the control group (MiSight) increased by -0.48 ± 0.47 D and 0.22 ± 0.13 mm, respectively, in the right eye and by -0.50 ± 0.44 D and 0.23 ± 0.14 mm, respectively, in the left eye, with no significant differences observed between the two lens types. CONCLUSIONS: The one-year results from this clinical trial show that the multifocal soft contact lenses used in the experimental group have a similar myopia control efficacy with respect to spherical equivalent refraction and axial length elongation as a commercially available dual focus soft contact lens design.

14.
Heliyon ; 10(11): e32544, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38961956

RESUMO

Background: Lumbar mobility is regarded as important for assessing and managing low back pain (LBP). Inertial Measurement Units (IMUs) are currently the most feasible technology for quantifying lumbar mobility in clinical and research settings. However, their gyroscopes are susceptible to drift errors, limiting their use for long-term remote monitoring. Research question: Can a single tri-axial accelerometer provide an accurate and feasible alternative to a multi-sensor IMU for quantifying lumbar flexion mobility and velocity? Methods: In this cross-sectional study, 18 healthy adults performed nine repetitions of full spinal flexion movements. Lumbar flexion mobility and velocity were quantified using a multi-sensor IMU and just the tri-axial accelerometer within the IMU. Correlations between the two methods were assessed for each percentile of the lumbar flexion movement cycle, and differences in measurements were modelled using a Generalised Additive Model (GAM). Results: Very high correlations (r > 0.90) in flexion angles and velocities were found between the two methods for most of the movement cycle. However, the accelerometer overestimated lumbar flexion angle at the start (-4.7° [95 % CI -7.6° to -1.8°]) and end (-4.8° [95 % CI -7.7° to -1.9°]) of movement cycles, but underestimated angles (maximal difference of 4.3° [95 % CI 1.4° to 7.2°]) between 7 % and 92 % of the movement cycle. For flexion velocity, the accelerometer underestimated at the start (16.6°/s [95%CI 16.0 to 17.2°/s]) and overestimated (-12.3°/s [95%CI -12.9 to -11.7°/s]) at the end of the movement, compared to the IMU. Significance: Despite the observed differences, the study suggests that a single tri-axial accelerometer could be a feasible tool for continuous remote monitoring of lumbar mobility and velocity. This finding has potential implications for the management of LBP, enabling more accessible and cost-effective monitoring of lumbar mobility in both clinical and research settings.

15.
Front Neurol ; 15: 1432608, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38962475

RESUMO

Purpose: To evaluate the utility of supine roll test (SRT) and alternative positional tests, such as head-shaking test (HST), seated supine positioning test (SSPT), bow and lean test (BLT), and rapid axial roll test (RART) in determining the affected semicircular canal of horizontal semicircular canal benign paroxysmal positional vertigo (HSC-BPPV). Methods: In an observational cohort study, 553 patients diagnosed with HSC-BPPV were divided into five groups in terms of different positional tests received: SRT group (n = 110), HST+ SRT (n = 112), BLT + SRT (n = 114), SSPT+SRT (n = 108) and RART+SRT (n = 109). The same method was used for the last four groups: The patients were first subjected to different alternative positional tests and then to SRT, and the nystagmus was observed separately to determine the affected side. The primary outcomes compared included the accuracy and sensitivity of these tests in the determination of the affected semicircular canal in HSC-BPPV. Results: Patients with nystagmus elicited by positional tests accounted for 84.99% (470/553). The elicitation rate of nystagmus of SRT was lowest, being 77.27% (85/110). The elicitation rate of nystagmus were higher in the test groups than in the control group, and RART+SRT group yielded the highest elicitation rate of nystagmus (95.41%, 104/109). Among the alternative positional tests, RART attained the highest elicitation rate of nystagmus (101/109, 92.66%). Comparison between alternative positional tests and SRT, RART and SRT showed obviously better agreement in determining the affected semicircular canal (85.45%, 96/109) and eliciting nystagmus (95.41%, Kappa = 0.642), but no difference was found in curative effect when the affected side was accurately determined (χ2 = 1.618, p = 0.655). Conclusion: All alternative positional tests are helpful for eliciting nystagmus in patients with HSC-BPPV, and the significant advantages of RART include high-sensitivity in eliciting nystagmus and high accuracy in determining the affected semicircular canal, which provided objective support for the correct diagnosis of HSC-BPPV and the successful reduction of otolith.

16.
Cureus ; 16(6): e61593, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38962608

RESUMO

Inflammatory back pain is a characteristic of spondyloarthritis. It is not, however, an exclusive symptom of inflammatory rheumatic diseases as it can also be associated with non-inflammatory entities. Infrequently, the etiology can be found in neoplastic conditions such as malignant lymphoma. Even in the presence of comorbidities indicatory of underlying rheumatic disease, like psoriasis vulgaris, the clinician should not be led astray. It is essential to pay attention to contradictory findings, as treatment crucially differs depending on diagnosis. Herein, we report on a psoriasis patient who presented with characteristic inflammatory back pain and deceptive imaging results. While the patient was initially thought to suffer from an inflammatory rheumatic disease with axial involvement, it was the accompanying atypical circumstances, particularly her age, that instantly challenged the diagnosis of axial psoriatic arthritis. She was eventually diagnosed with stage IV follicular lymphoma that manifested with rare and exclusively extranodal lesions and spondyloarthritis-like morphology. This case effectively demonstrates the importance of a thorough diagnostic workup and how certain clinical factors, such as the patient's age, should be considered when confronted with inflammatory back pain.

17.
Clin Interv Aging ; 19: 1153-1162, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38952872

RESUMO

Background: To investigate association between optic disc parameters analyzed by optical coherence tomography (OCT) and occurrence of peripheral retinal tears in patients with symptomatic posterior vitreous detachment (PVD). Methods: This cross-sectional study enrolled 75 patients with symptoms of acute PVD, who were allocated into two groups based on whether a peripheral retinal tear occurred or not. Results: When comparing the average retinal nerve fiber layer (RNFL) thickness (µm) between retinal tear and control groups, it was shown that patients with a retinal tear have a significantly higher (87.18 [95% confidence interval (CI), 84.47 to 89.9] vs 81.14 [95% CI, 77.81 to 84.46], P = 0.005) average RNFL thickness. Furthermore, we observed a significant difference (0.13, 0.06 to 0.22 vs 0.07, 0.04 to 0.1, P = 0.036, Mann-Whitney U-test) in the size of cup volume (mm3) between the tear and control groups, respectively. Linear regression showed a significant decrease (P = 0.029) in average RNFL thickness with increasing age, but without a significant difference between the two groups. There was no statistically significant difference between the tear and control groups in terms of rim area, disc area, and average cup-to-disc ratio. Conclusion: Patients with a higher average RNFL thickness and larger cup volume measured by OCT were more prone to develop a peripheral retinal tear. Increased peripapillary average RNFL thickness due to trauma and subsequent inflammation, possibly related to the more adherent posterior hyaloid membrane to the retina, may also indicate strengthened adhesions in the areas of the peripheral retina where retinal tears occur. OCT analysis of the optic nerve head may be used in everyday clinical practice as a predictor of the development of peripheral retinal tears in patients with symptomatic PVD.


Assuntos
Fibras Nervosas , Disco Óptico , Perfurações Retinianas , Tomografia de Coerência Óptica , Descolamento do Vítreo , Humanos , Estudos Transversais , Masculino , Feminino , Descolamento do Vítreo/diagnóstico por imagem , Pessoa de Meia-Idade , Disco Óptico/diagnóstico por imagem , Perfurações Retinianas/diagnóstico por imagem , Idoso , Fibras Nervosas/patologia , Adulto , Modelos Lineares
18.
Open Biol ; 14(7): 240139, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38955223

RESUMO

The vertebrate organizer plays a crucial role in building the main (antero-posterior) axis of the embryo: it neuralizes the surrounding ectoderm, and is the site of emigration for cells making axial and paraxial mesendoderm during elongation. The chick organizer becomes a stem zone at the onset of elongation; it stops recruiting cells from the neighbouring ectoderm and generates all its derivatives from the small number of resident cells it contains at the end of gastrulation stages. Nothing is known about the molecular identity of this stem zone. Here, we specifically labelled long-term resident cells of the organizer and compared their RNA-seq profile to that of the neighbouring cell populations. Screening by reverse transcription-polymerase chain reaction and in situ hybridization identified four genes (WIF1, PTGDS, ThPO and UCKL1) that are upregulated only in the organizer region when it becomes a stem zone and remain expressed there during axial elongation. In experiments specifically labelling the resident cells of the mature organizer, we show that only these cells express these genes. These findings molecularly define the organizer as a stem zone and offer a key to understanding how this zone is set up, the molecular control of its cells' behaviour and the evolution of axial growth zones.


Assuntos
Regulação da Expressão Gênica no Desenvolvimento , Organizadores Embrionários , Animais , Embrião de Galinha , Organizadores Embrionários/metabolismo , Padronização Corporal/genética , Gastrulação/genética , Transcriptoma , Perfilação da Expressão Gênica
19.
Ophthalmology ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38972357

RESUMO

PURPOSE: To investigate the myopia control efficacy of novel Lenslet-ARray-Integrated (LARI) spectacle lenses with positive (PLARI) and negative (NLARI) power lenslets worn for one year in myopic children. DESIGN: Randomized, double-masked, controlled clinical trial. PARTICIPANTS: A total of 240 children, aged 6 to 12 years, with spherical equivalent refraction (SER) between -4.00 and -1.00 diopter (D), astigmatism of 1.50 D or less, and anisometropia of 1.00 D or less. METHODS: Participants were assigned randomly in a 1:1:1 ratio to PLARI, NLARI, and a control (single-vision (SV)) groups. Cycloplegic autorefraction and axial length were measured at baseline and 6-month intervals after lens wear. MAIN OUTCOME MEASURES: Changes in SER, axial elongation (AE), and differences between groups. RESULTS: After 1-year, SER changes and AE in the PLARI and NLARI groups were significantly less than those in the SV group (SER: -0.30 ± 0.48 D, -0.21 ± 0.35 D, -0.66 ± 0.40 D; AE: 0.19 ± 0.20 mm, 0.17 ± 0.14 mm, 0.34 ± 0.18 mm, respectively) (all P < 0.001). There were no significant differences in SER changes and AE between PLARI and NLARI groups (P = 0.54 and P = 1.00, respectively). Younger age was associated with more rapid SER increase and larger AE in the SV (r = 0.40, P < 0.001 and r = -0.59, P < 0.001, respectively) and PLARI (r= 0.46, P < 0.001 and r = -0.52, P < 0.001, respectively) groups, but not in the NLARI group (r = -0.002, P = 0.98 and r = -0.08, P = 0.48, respectively). CONCLUSIONS: Compared with the SV group, both PLARI and NARI groups showed significantly slower myopia progression in terms of SER and axial elongation. Faster myopia progression, in terms of both SER and AE, was associated with younger age in the SV and PLARI groups, but not in the NLARI group.

20.
Saudi J Ophthalmol ; 38(2): 152-156, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38988782

RESUMO

PURPOSE: The purpose of the study is to establish normative values of eye parameters such as lens thickness (LT), lens diameter (LD), and axial length (AXL) among wide age range of Saudis using Pentacam AXL and compare these values between gender, in addition to that, to find the correlation between the age and those parameters. METHODS: In this prospective cross-sectional study, we measured LT, LD, and AXL in 125 healthy Saudi controls aged between 8 and 60 years using OCULUS Pentacam AXL. The screening tests were performed for each subject to exclude any ocular abnormalities using slit lamp (Haag-Streit BQ 900), refractive error measured using auto refractometer (Topcon KR-1 Autorefractor/Keratometer), and subject who has spherical equivalent more than ± 4.00D and astigmatism more than 1.00DC was excluded from the study. The mean of three readings of LT, LD, and AXL was taken. All examination was applied on one eye (right eye). RESULTS: The overall mean and standard deviation of LT, LD, and AXL was 2.2 mm ± 0.5, 2.7 mm ± 0.6, and 23.8 mm ± 1.0, respectively. There was no statistically significant difference between males and females in these parameters in all age groups, except in Group 2 (age: 19-30 years), there was a statistically significant difference between males and females in AXL, mean difference (M = 0.48), and P = 0.015. The mean of LT and LD was negatively associated with age. However, there was no significant correlation between AXL and age. CONCLUSION: Normative values of LT, LD, and AXL have been established in wide age group of healthy Saudis; the findings of the present study can highlight not only the normal range of the different ocular parameters, namely LT, LD, and AXL, but also their variation with age and gender.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...