1.
Adv Nutr ; : 100290, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39151753

RESUMO

Accurate and precise measurement of hemoglobin concentration is critical for reliable estimations of anemia prevalence at the population level. When systematic and/or random error are introduced in hemoglobin measurement, estimates of anemia prevalence might be significantly erroneous and, hence, limit their usefulness. For decades, single-drop capillary blood has been the most common blood source used for the measurement of hemoglobin concentration in surveys, especially in low-income and middle-income countries. In this study, we highlight historical and emerging evidence that single-drop capillary blood introduces a high degree of random error (variability) to hemoglobin estimates, leading to less reliable estimates of anemia prevalence at the population level. At present, the best practice is to collect and use venous blood for measurement of hemoglobin with an automated hematology analyzer, following standard operating procedures and quality assurance measures. Where use of an automated analyzer is not possible, the analysis of venous blood in a point-of-care hemoglobinometer by trained phlebotomists or specimen collectors should be considered. A forthcoming systematic review will provide additional evidence on the accuracy and precision of single-drop capillary blood for hemoglobin assessment. In the meantime, we raise caution when using single-drop capillary blood for hemoglobin measurement as it can result in inaccurate hemoglobin estimates and less reliable anemia prevalence estimates.

2.
Proteomics ; 24(16): e2300607, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38783781

RESUMO

In this study, we sought to compare protein concentrations obtained from a high-throughput proteomics platform (Olink) on samples collected using capillary blood self-collection (with the Tasso+ device) versus standard venipuncture (control). Blood collection was performed on 20 volunteers, including one sample obtained via venipuncture and two via capillary blood using the Tasso+ device. Tasso+ samples were stored at 2°C-8°C for 24-hs (Tasso-24) or 48-h (Tasso-48) prior to processing to simulate shipping times from a study participant's home. Proteomics were analyzed using Olink (384 Inflammatory Panel). Tasso+ blood collection was successful in 37/40 attempts. Of 230 proteins included in our analysis, Pearson correlations (r) and mean coefficient of variation (CV) between Tasso-24 or Tasso-48 versus venipuncture were variable. In the Tasso-24 analysis, 34 proteins (14.8%) had both a correlation r > 0.5 and CV < 0.20. In the Tasso-48 analysis, 68 proteins (29.6%) had a correlation r > 0.5 and CV < 0.20. Combining the Tasso-24 and Tasso-48 analyses, 26 (11.3%) proteins met these thresholds. We concluded that protein concentrations from Tasso+ samples processed 24-48 h after collection demonstrated wide technical variability and variable correlation with a venipuncture gold-standard. Use of home capillary blood self-collection for large-scale proteomics should be limited to select proteins with good agreement with venipuncture.


Assuntos
Coleta de Amostras Sanguíneas , Proteômica , Humanos , Proteômica/métodos , Coleta de Amostras Sanguíneas/métodos , Masculino , Adulto , Feminino , Flebotomia/métodos , Proteínas Sanguíneas/análise , Ensaios de Triagem em Larga Escala/métodos , Pessoa de Meia-Idade
3.
Int J Lab Hematol ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695255

RESUMO

INTRODUCTION: A polyvalent blood collection tube could potentially reduce the number and volume of blood samples drawn from patients and reduce the risk of tube mix-ups in a point-of-care setting in the emergency department and the intensive care unit. METHODS: Four different concentrations of our experimental heparin anticoagulant with iloprost additive (HEP-ILOP 50 nM, 150 nM, 1000 nM, and 10 µM, respectively) were tested for significant differences and bias performance specifications against EDTA for 29 hematology analytes, and the highest concentration (HEP-ILOP 10 µM) against lithium heparin for 14 chemistry and immunochemistry analytes. Samples were drawn from 79 consenting subjects from the Oncology Department (n = 38) and the Intensive and Intermediary Care Unit (n = 41). RESULTS: For hematology analytes, the HEP-ILOP formulation generally provided stable measurement within optimal requirements within 5 h after sampling (mean 104 ± 56 min), with very little difference between the four HEP-ILOP concentrations. Because of differences in platelet and red blood cell swelling between EDTA and HEP-ILOP, all size-dependent analytes required proportional factorization to produce similar results. Platelet count by impedance similarly required factorization, whereas the fluorescent method provided results identical with EDTA. Chemistry and immunochemistry analytes were within optimal requirements except for potassium, lactate dehydrogenase, and glucose, indicating a cytoprotective effect of iloprost reducing cell metabolism and rupture, thereby producing results closer to in vivo conditions. CONCLUSIONS: Our novel dry-sprayed anticoagulant formulation, HEP-ILOP, is a promising candidate for a polyvalent blood collection tube, enabling the analysis of hematology, chemistry, and immunochemistry analytes in the same tube.

4.
Biochem Med (Zagreb) ; 34(2): 020702, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38665875

RESUMO

Introduction: The aim of this study was to determine the level of compliance of venous blood sampling (VBS) in Lithuania with the joint recommendations of the European Federation of Clinical Chemistry and Laboratory Medicine and the Latin American Confederation of Clinical Biochemistry (EFLM-COLABIOCLI) and to analyse possible causes of errors. A survey was conducted between April and September 2022. Materials and methods: A self-designed questionnaire was distributed to the Lithuanian National Societies. Error frequencies and compliance score were computed. Differences between groups were analysed using Pearson's chi-square, Fisher's exact criterion, Mann-Whitney U (for two groups), or Kruskal-Wallis (for more than two groups) for categorical and discrete indicators. The association between ordinal and discrete variables was assessed using Spearman's rank correlation coefficient. Statistical significance was determined at P < 0.05. Results: A total of 272 respondents completed the questionnaire. Median error rate and compliance score were 31.5% and 13/19, respectively. Significant differences were found among professional titles, standard operating procedures availability, training recency, and tourniquet purpose opinions. A negative correlation was noted between compliance and time since training (rs = - 0.28, P < 0.001). Conclusions: The findings of this study indicate that there is a significant need for improvement in compliance with the EFLM-COLABIOCLI recommendations on VBS among specialists in Lithuania. Essential measures include prioritizing ongoing phlebotomy training and establishing national guidelines. Harmonisation of blood collection practices across healthcare institutions is crucial.


Assuntos
Flebotomia , Humanos , Lituânia , Flebotomia/normas , Inquéritos e Questionários , Fidelidade a Diretrizes , Feminino , Masculino
5.
J Korean Soc Radiol ; 85(2): 456-462, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38617865

RESUMO

Primary aldosteronism is a group of disorders in which the autonomous secretion of aldosterone is associated with hypertension and hypokalemia. It is crucial to determine the laterality of aldosterone hypersecretion because treatment options differ accordingly. Adrenal venous sampling (AVS) is considered the most reliable method for assessing the laterality of primary aldosteronism. This procedure is often technically challenging because of the small size and varied locations of the adrenal veins. A better understanding of anatomical variations and careful review of imaging studies would improve sampling success. This report presents three cases of anatomical variations encountered during AVS.

6.
Patient Prefer Adherence ; 18: 531-541, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38444755

RESUMO

Purpose: Typical barriers to venous blood collection for wellness testing include discomfort, time spent, and collection site accessibility. This study assessed individuals' experience, satisfaction, and preference associated with a FDA-cleared blood-collection device, the BD MiniDraw™ Capillary Blood Collection System (BD MiniDraw), in retail locations. Patients and Methods: A total of 113 individuals (≥18 years) with venous blood collection experience were enrolled; 107 completed the study. A pre-collection survey gathered information on demographics and past experiences with healthcare and venous blood collection settings. BD MiniDraw collection was conducted at three retail sites (two pharmacies and one grocery store) by trained healthcare workers using the Babson BetterWay blood testing service model. A follow up survey was performed two weeks later to determine experience with, and preference for, BD MiniDraw in terms of staff professionalism, blood collection location, blood collection time, and staff trustworthiness. Results: Among the 107 participants, 74 (69%) were female and 33 (31%) were male; the mean age was 49 years (range=18-71 years). Sixty-six (62%) participants viewed their prior venipuncture experience as "somewhat" or "very" positive. Following capillary collection, 96 (90%) participants expressed a "somewhat" or "very" positive experience with BD MiniDraw at a retail location. In particular, "very satisfied" responses were given for location (87/107; 81%) and collection time (78/1407; 73%). In a subset of respondents (n=89), those reasons (location and time savings) were most frequent for likelihood of future use. Ninety-nine participants (92%) rated the retail blood collection team as "very" or "extremely" trustworthy. Overall, 90 participants (84%) "strongly preferred" (56/107; 52%), "somewhat preferred" (14/107; 13%), or had "no preference" (20/107; 19%) for BD MiniDraw, compared to traditional venous blood collection. Conclusion: Most participants conveyed a preference for BD MiniDraw, primarily based on the blood collection retail location, perceived time savings, and professionalism and trustworthiness of the staff.

7.
BMC Pediatr ; 24(1): 110, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38350923

RESUMO

INTRODUCTION: Due to medical procedures, preterm infants are at high risk for side effects of pain. In this regard, heel lancing for capillary blood sampling is a common painful procedure. The present study was conducted to assess the effectiveness of a simulated intrauterine sound on behavioral and physiological indices of pain due to heel-prick blood sampling in preterm infants. METHODS: A double­blind randomized clinical trial (RCT) was conducted. The data were collected from September 23 to December 22, 2019. We measured the effect of a simulated intrauterine sound on changes in the behavioral and physiological parameters of pain (heart rate, SPO2) caused by heel lance that was measured 5 min before the intervention, during the sampling, and 5 min after the procedure. We measured behavioral pain by video recording the infants' faces and then the scoring neonatal infant pain scale (NIPS). Heart rate and SPO2 were measured using a pulse oximeter device. The data were analyzed using analysis of variance (ANOVA) and independent t­test in SPSS software version 20.0. RESULTS: Eighty infants were randomized (40 in each group). Mean scores NIPS during and after intervention were in the intervention group (3.55 ± 0.84, 95% CI: 3.30-3.80(, and (1.15 ± 0.84, 95%: 0.95-1.35) and in the control group (5.57 ± 0.95, 95% CI:5.30-5.85) and (3.00 ± 0.98) respectively. There were significant differences in scores of NIPS between the two study groups during (p < 0.001) and five min after heel lancing (p < 0.001). Mean scores of heart rate in the three phases of before, during, and five min after the intervention were respectively in the intervention group (127.57 ± 4.45, 95% CI:126.27-128.99), (131.07 ± 6.54, 95% CI:129.20-133.22), (128.45 ± 5.15, 95% CI:127.02-130.07) and in the control group (128.67 ± 4.57, 95% CI:127.32-130.07), (136.07 ± 7.24, 95% CI:133.90-138.37), and (132.42 ± 6.47, 95% CI:130.37-134.49). There were significant differences in heart rate between the intervention and the control group during (p = 0.002) and five min after the heel lance (p = 0.003). Mean scores of SPO2 in the three phases of baseline, during, and five min after the intervention were respectively in the intervention group (96.72 ± 0.93, 95% CI:96.42-97.00), (91.47 ± 1.46, 95% CI:91.05-91.92), (94.17 ± 1.03, 95% CI:93.22-94.00) and in the control group (96.6 ± 0.84, 95% CI:96.35-96.85), (91.5 ± 1.24, 95% CI:91.12-91.87), and (93.60 ± 1.27, 95% CI:93.85-94.50). CONCLUSION: This study showed that the simulated intrauterine sound reduces the behavioral pain and heart rate in the intervention group during and after heel lance. These results suggest using the method during the painful heel lancing to reduce pain parameters in preterm infants.


Assuntos
Coleta de Amostras Sanguíneas , Recém-Nascido Prematuro , Recém-Nascido , Humanos , Coleta de Amostras Sanguíneas/efeitos adversos , Coleta de Amostras Sanguíneas/métodos , Dor/etiologia , Dor/prevenção & controle , Punções/efeitos adversos , Manejo da Dor/efeitos adversos , Manejo da Dor/métodos
8.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1020494

RESUMO

Objective:To analyze the effect of different vascular access on the outcome in peripheral blood stem cells collection by a network Meta-analysis, and to provide a reference for clinical medical staff to select the best vascular access.Methods:A systematic search was carried out in Chinese Knowledge Infrastructure database (CNKI), Wanfang Database, VIP Database, Chinese Biomedical Literature Database, Cochrane Library, Web of Science, PubMed, Embase, from inception until April 15, 2023. Two researchers independently screened literature and extracted data. Bayesian network meta-analysis was performed using R4.2.2 and Addis-1.16.6 softwares.Results:A total 7 pieces of research were included, 5 vascular access methods were peripheral artery, peripheral vein, artery-vein, femoral vein-central venous catheter (FV-CVC), and internal jugular vein-CVC (IJV-CVC). The results showed that compared with the peripheral veins, there was no significant difference on CD34 cells between other vascular accesses in the primary outcome measure when collected peripheral blood stem cell collection. On the single blood volume treatment time, peripheral vein and IJV-CVC were statistically significant ( MD = 14.80, 95% CI 2.70-22.38, P<0.05) . The SUCRA ranking probability chart showed that on CD34 cells, FV- CVC>IJV-CVC>artery-vein>peripheral artery>peripheral vein access; for a single blood volume treatment time and monocyte number, peripheral artery was superior and the next was peripheral vein. Conclusions:Current evidence suggested that Peripheral artery may be the best vascular access in peripheral blood stem cells collection, which opens a new way to establish the vascular access for peripheral blood stem cells collection, but it needs to be confirmed by large clinic trials.

9.
Medicina (Kaunas) ; 59(11)2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-38003952

RESUMO

Platelet-rich fibrin (PRF) is a second-generation platelet concentrate whose use in clinical practice has been widely disseminated. This has led to the development of several commercial protocols, creating great confusion as to the terminology and implications of each of them. This integrative review aims to identify the critical factors of each of the phases of the solid-based PRF matrix protocol and their possible influence on their macro- and microscopic characteristics. An electronic search of the MEDLINE database (via PubMed), Web of Science, Scopus, LILACS, and OpenGrey was carried out. The search was temporarily restricted from 2001 to 2022. After searching, 43 studies were included that met the established criteria. There were numerous factors to consider in the PRF protocol, such as the material of the blood collection tubes, the duration of phlebotomy, the parameters related to blood centrifugation, the time from centrifugation to dehydration of the fibrin clots and their dehydration into membranes, as well as the time to clinical use. These factors influenced the macro- and microscopic characteristics of the PRF and its physical properties, so knowledge of these factors allows for the production of optimised PRF by combining the protocols and materials.


Assuntos
Fibrina Rica em Plaquetas , Cirurgia Bucal , Humanos , Desidratação , Leucócitos , Plaquetas
10.
Artigo em Inglês | MEDLINE | ID: mdl-37997299

RESUMO

AIMS: The aim of this study is to measure staff compliance with the local umbilical cord lactate (UCL) sampling guideline and investigate the quality of paired UCG samples at a tertiary maternity unit. METHODS: We performed a retrospective consecutive sampling of 100 babies delivered via emergency caesarean section and 50 babies with each of all other guideline-based indications for UCL sampling born on and before 31 December 2021. Data were extracted from physical and electronic records. Compliance with guideline-based indications for UCL at birth was measured. The proportion of valid UCG samples was calculated. Samples were considered invalid under the following cases: (i) inadvertently collecting from the same vessel, (ii) switching arterial and venous samples, (iii) collecting from only one vessel or (iv) committing errors during sample collection and handling. RESULTS: Of the samples collected at birth from 321 babies, 280 (87%) had UCL. Small for gestational age and concerns about fetal well-being in labour were indications associated with poorer compliance, 66% and 78%, respectively. About 99 (44%) babies of 226 babies with UCG performed had valid UCG samples. The most common reasons for invalid samples were collection and handling errors (22%) and inadvertent collection from the same vessel (15%). CONCLUSIONS: Generally, compliance with the guidelines is good. However, invalid UCG samples were more frequent than expected.

11.
Artigo em Inglês | MEDLINE | ID: mdl-37423775

RESUMO

BACKGROUND: Anemia associated with blood extraction for diagnostic purposes is a highly prevalent entity in intensive care units (ICU) for adults. The evidence recommends its prevention through different strategies, among which we can find the use of closed blood sampling systems (CBSS). Different experimental studies support the use of these devices. OBJECTIVE: To identify knowledge gaps regarding the effectiveness of CBSS in ICU patients. METHODS: Scoping review with search in PubMed, CINAHL, Embase, Cochrane Library and Joanna Briggs Institute databases, between September-2021 and September-2022. No time, language, or other limits were applied to ensure the recovery of all relevant studies. Gray literature sources: DART-Europe, OpenGrey and Google Scholar. Two researchers independently reviewed titles and abstracts and assessed full texts against the inclusion criteria. The following data was extracted for each study: design and sample, inclusion and exclusion criteria, variables, type of CBSS, results and conclusions. RESULTS: 18 articles were included in the final review, 11 clinical trials (RCTs) published between 1992 and 2014. Three systematic reviews were found, but they only analyzed the effect of CBSS in reducing blood loss, hemoglobin stabilization, and the need for transfusion. Five of the RCTs analyzed the risk of infection, one catheter complications, and two alterations in blood pressure readings. CONCLUSIONS: The use of CBSS is recommended to reduce blood loss in ICUs. However, there are discrepancies about their ability to prevent anemia and/or the need for blood transfusion. Its use does not increase catheter-related infection rates or alter the measurement of mean arterial pressure.

12.
World J Emerg Med ; 14(4): 257-264, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37425086

RESUMO

BACKGROUND: In patients with chest pain who arrive at the emergency department (ED) by ambulance, venous access is frequently established prehospital, and could be utilized to sample blood. Prehospital blood sampling may save time in the diagnostic process. In this study, the association of prehospital blood draw with blood sample arrival times, troponin turnaround times, and ED length of stay (LOS), number of blood sample mix-ups and blood sample quality were assessed. METHODS: The study was conducted from October 1, 2019 to February 29, 2020. In patients who were transported to the ED with acute chest pain with low suspicion for acute coronary syndrome (ACS), outcomes were compared between cases, in whom prehospital blood draw was performed, and controls, in whom blood was drawn at the ED. Regression analyses were used to assess the association of prehospital blood draw with the time intervals. RESULTS: Prehospital blood draw was performed in 100 patients. In 406 patients, blood draw was performed at the ED. Prehospital blood draw was independently associated with shorter blood sample arrival times, shorter troponin turnaround times and decreased LOS (P<0.001). No differences in the number of blood sample mix-ups and quality were observed (P>0.05). CONCLUSION: For patients with acute chest pain with low suspicion for ACS, prehospital blood sampling is associated with shorter time intervals, while there were no significant differences between the two groups in the validity of the blood samples.

13.
Clin Chem Lab Med ; 61(11): 2002-2009, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37270688

RESUMO

OBJECTIVES: Contamination of blood samples from patients receiving intravenous fluids is a common error with potential risk to the patient. Algorithms based on the presence of aberrant results have been described but have the limitation that not all infusion fluids have the same composition. Our objective is to develop an algorithm based on the detection of the dilution observed on the analytes not usually included in infusion fluids. METHODS: A group of 89 cases was selected from samples flagged as contaminated. Contamination was confirmed by reviewing the clinical history and comparing the results with previous and subsequent samples. A control group with similar characteristics was selected. Eleven common biochemical parameters not usually included in infusion fluids and with low intraindividual variability were selected. The dilution in relation to the immediate previous results was calculated for each analyte and a global indicator, defined as the percentage of analytes with significant dilution, was calculated. ROC curves were used to define the cut-off points. RESULTS: A cut-off point of 20 % of dilutional effect requiring also a 60 % dilutional ratio achieved a high specificity (95 % CI 91-98 %) with an adequate sensitivity (64 % CI 54-74 %). The Area Under Curve obtained was 0.867 (95 % CI 0.819-0.915). CONCLUSIONS: Our algorithm based on the global dilutional effect presents a similar sensitivity but greater specificity than the systems based on alarming results. The implementation of this algorithm in the laboratory information systems may facilitate the automated detection of contaminated samples.


Assuntos
Serviços de Laboratório Clínico , Laboratórios Clínicos , Humanos , Curva ROC , Fezes , Algoritmos
14.
Diagnostics (Basel) ; 13(10)2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37238237

RESUMO

Blood-based diagnostics are critical for many medical decisions, but mostly rely on venepuncture, which can be inconvenient and painful. The Onflow Serum Gel (Loop Medical SA, Vaud, Lausanne, Switzerland) is a novel blood collection device that utilises needle-free technology to collect capillary blood. In this pilot study, 100 healthy participants were enrolled and provided two Onflow collected specimens and one venous blood specimen. Five chemistry analytes (AST, ALT, LDH, potassium, creatinine) and haemolysis were measured per specimen, and laboratory analyte results were compared. Onflow was found to be more acceptable than venepuncture with lower pain ratings, and 96.5% of participants would use the Onflow method again. All phlebotomists (100%) found Onflow intuitive and user-friendly, with ~1 mL of Onflow blood successfully collected from 99% of participants in <12 min (mean: 6 min, 40 s) and 91% collected on the first attempt. ALT and AST analytes showed no difference in performance, while creatinine generated a negative bias (-5.6 µmol/L), and increased variability was noted with potassium (3.6%CV) and LDH (6.7%CV), although none were clinically relevant. These differences may be due to 35% of Onflow collected specimens having "mild" haemolysis. Onflow is a promising alternative blood collection device that should now be evaluated in participants with expected abnormal chemistries and as an option for self-collection.

15.
Afr J Lab Med ; 12(1): 2008, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37063603

RESUMO

Between April and May 2022, 10 healthy adult non-patients were recruited from Pusan National University Hospital. Venous blood drawn into a syringe was transferred into test tubes with a zero-to-45-minute delay. The transfer was done sequentially in two positions with the syringe and the needle adaptor end (1) heading downwards and (2) heading upwards. Haemoglobin levels gradually increased over time in position 1 transfer while they gradually decreased in position 2. Therefore, blood must be transferred quickly from a syringe to a tube for reliable test results. What this study adds: Our findings confirm that delays between blood collection and transfer can affect haemoglobin levels.

16.
Ann Clin Biochem ; 60(4): 259-269, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36750422

RESUMO

BACKGROUND: The COVID-19 has led to a significant increase in demand for remote blood sampling in clinical trials. This study aims to ascertain the concordance between venous versus capillary samples, processed immediately or exposed to various pre-analytical conditions. METHODS: Participants (≥12 years old) provided a venous blood sample (processed immediately) and capillary samples allocated to one of the following conditions: processed immediately or exposed to 12-, 24-, or 36-h delays at room temperature or 36-h delays with a freeze-thaw cycle. The analytes of interest included SARS-CoV-2 IgG, 25-hydroxy vitamin D (25(OH)D), alkaline phosphate (ALP), calcium (Ca), phosphate (Ph), and c-reactive protein (CRP). Paired samples were considered interchangeable if they met three criteria: minimal within-subject mean difference, 95% of values within desirable total errors, and inter-class correlation (ICC) > 0.90. RESULTS: 90 participants (44.1% male) were enrolled. When comparing rapidly processed venous with capillary samples, 25(OH)D, ALP, and CRP met all three criteria; SARS-CoV-2 IgG met two criteria (mean difference and ICC); and Ca and Ph met one criterion (mean difference). When considering all three criteria, concentrations of 25(OH)D, CRP, and ALP remained unchanged after delays of up to 36 h; SARS-CoV-2 IgG met two criteria (mean difference and ICC); Ca and Ph met one criterion (mean difference). CONCLUSION: These findings suggest that remote blood collection devices can be used to measure anti-SARS-CoV-2 IgG, 25(OH)D, CRP, and ALP. Further analysis is required to evaluate the interchangeability between venous and capillary testing in Ca and Ph levels, which are more sensitive to pre-analytical conditions.


Assuntos
COVID-19 , Humanos , Masculino , Criança , Feminino , COVID-19/diagnóstico , Calcificação Fisiológica , SARS-CoV-2 , Fosfatos , Proteína C-Reativa , Cálcio , Anticorpos Antivirais , Imunoglobulina G
17.
Aust Crit Care ; 36(6): 1129-1137, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36635184

RESUMO

OBJECTIVES: The objective of this study was to critically appraise and synthesise evidence for blood conservation strategies in intensive care. Blood sampling is a critical aspect of intensive care to guide clinical decision-making. Repeated blood sampling can result in blood waste and contamination, leading to iatrogenic anaemia and systemic infection. REVIEW METHOD USED: Cochrane systematic review methods were used including meta-analysis, and independent reviewers. DATA SOURCES: A systematic search was conducted in Medline, CINAHL, PUBMED and EMBASE databases. The search was limited to randomised controlled trials (RCTs) and cluster RCTs, published in English between 2000 and 2021. REVIEW METHODS: Paired authors independently assessed database search results and identified eligible studies. Trials comparing any blood conservation practice or product in intensive care were included. Primary outcomes were blood sample volumes and haemoglobin change. Secondary outcomes included proportion of patients receiving transfusions and infection outcomes. Quality appraisal employed the Cochrane Risk of Bias tool. Meta-analysis using random effects approach and narrative synthesis summarised findings. RESULTS: Eight studies (n = 1027 patients), all RCTs were eligible. Six studies included adults, one studied paediatrics and one studied preterm infants. Seven studies evaluated a closed loop blood sampling system, and one studied a conservative phlebotomy protocol. Studies were of low to moderate quality. Meta-analysis was not possible for interventions targeting blood sample volumes or haemoglobin. Decreased blood sample volumes reported in four studies were attributable to a closed loop system or conservative phlebotomy. No study reported a significant change in haemoglobin. Meta-analysis demonstrated that use of a closed system (compared to open system) reduced the proportion of patients receiving transfusion [Risk Ratio (RR) 0.65, 95% CI 0.46-0.92; 287 patients] and reduced intraluminal fluid colonisation [RR 0.25, 95% CI 0.07-0.58; 500 patients]. CONCLUSIONS: Limited evidence demonstrates closed loop blood sampling systems reduced transfusion use and fluid colonisation. Simultaneous effectiveness-implementation evaluation of these systems and blood conservation strategies is urgently required. PROSPERO PROTOCOL REGISTRATION REFERENCE: CRD42019137227.


Assuntos
Cuidados Críticos , Recém-Nascido Prematuro , Recém-Nascido , Adulto , Humanos , Criança , Hemoglobinas
18.
Rev. enferm. UFPE on line ; 17(1): [1-16], jan. 2023. ilus, tab
Artigo em Inglês, Português | BDENF - Enfermagem | ID: biblio-1511739

RESUMO

Objetivo: avaliar a qualidade dos relatos de ensaios clínicos randômicos sobre realidade virtual durante a punção/cateterismo venoso periférico. Método: estudo avaliativo, realizado em duas etapas: revisão de escopo, no intuito de identificar ensaios clínicos randômicos sobre a temática, publicados nas bases de dados Cochrane, Cumulative Index to Nursing and Allied Health Literature, Embase, PubMed® e Literatura Latino-Americana e do Caribe em Ciências da Saúde; e avaliação da qualidade dos relatos dos ensaios clínicos randômicos, utilizandose do Consolidated Standards of Reporting Trials. Os dados foram analisados por meio de estatística descritiva e inferencial, sendo aplicado o Teste Kappa. Resultados: o total de estudos encontrados foram 291, sendo incluídos oito; destes, 75% apresentaram boa qualidade do relato, atendendo parcialmente os itens previamente definidos como necessários. Conclusão: os artigos apresentaram boa qualidade no relato, porém há necessidade de melhora na descrição dos itens.(AU)


Objective: to evaluate the quality of reports of randomized clinical trials on virtual reality during peripheral venous catheterization. Method: an evaluative study, conducted in two stages: scoping review, to identify randomized clinical trials on the subject, published in Cochrane, Cumulative Index to Nursing and Allied Health Literature, Embase, PubMed® and Latin American and Caribbean Health Sciences Literature databases; and quality assessment of the reports of randomized clinical trials, using the Consolidated Standards of Reporting Trials. Data were analyzed using descriptive and inferential statistics, and the Kappa Test was applied. Results: a total of 291 studies were found, eight of which were included. Of these, 75% showed good quality reporting, partially meeting the items previously defined as necessary. Conclusion: the articles presented good quality reports, but there is a need for improvement in the description of the items.(AU)


Objetivo: evaluar la calidad de los informes de ensayos clínicos aleatorizados sobre realidad virtual durante la punción/cateterismo venoso periférico. Método: estudio evaluativo, realizado en dos etapas: scoping review, con el fin de identificar ensayos clínicos aleatorizados sobre el tema, publicados en las bases de datos Cochrane, Cumulative Index to Nursing and Allied Health Literature, Embase, PubMed® y Literatura Latinoamericana y del Caribe en Ciencias de la Salud; y evaluación de la calidad de los informes de ensayos clínicos aleatorios, utilizando los Consolidated Standards of Reporting Trials. Los datos fueron analizados mediante estadística descriptiva e inferencial, utilizando la prueba de Kappa. Resultados: el total de estudios encontrados fue de 291, de los cuales se incluyeron ocho; de estos, el 75% presentó buena calidad del informe, cumpliendo parcialmente con los ítems previamente definidos como necesarios. Conclusión: los artículos presentaron buena calidad en el informe, pero hay necesidad de mejora en la descripción de los ítems.(AU)


Assuntos
Humanos , Masculino , Feminino , Cateterismo Periférico , Ensaios Clínicos Controlados Aleatórios como Assunto , Realidade Virtual , Coleta de Amostras Sanguíneas , PubMed
19.
Pract Lab Med ; 33: e00303, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36582816

RESUMO

Background: Clinical laboratory errors have a great impact on patient safety and treatment. Although specimen rejections result in longer turnaround times and increased health-care costs, different studies present inconsistent findings. Therefore, the study aimed to determine the pooled prevalence of blood specimen rejection in clinical laboratory. Methods: Electronic databases including MEDLINE, PubMed, EMBASE, HINARI, Cochrane Library, Google Scholar, and Science Direct were comprehensively searched. Articles were screened and the data extracted independently by authors. Publication bias was checked by funnel-plots and Egger's statistical test. Pooled prevalence was estimated using a random-effects model. The I2 statistical test were performed to assess heterogeneity. The possible sources of heterogeneity were analyzed through subgroup and sensitivity analysis. Results: Total of 26 articles with 16,118,499 blood sample requests were included in the meta-analysis. The pooled prevalence of blood specimen rejection in the clinical laboratory was 1.99% (95% CI: 1.73, 2.25). Subgroup analysis showed that, the highest prevalence of specimen rejection was observed in Asia [2.82% (95%CI: 2.21, 3.43)] and lowest in America [0.55% (95%CI: 0.27, 0.82)]. The leading cause of blood specimen rejection in clinical laboratories were clotted specimen (32.23% (95%CI: 21.02, 43.43)), hemolysis (22.87% (95%CI: 16.72, 29.02)), insufficient volume (22.81% (95%CI: 16.75, 28.87)), and labelling errors (7.31% (95%CI: 6.12, 8.58)). Conclusion: The pooled prevalence of blood specimen rejection rate is relatively high especially in developing regions. Therefore, proper training for specimen collectors, compliance with good laboratory practices specific to specimen collection, transportation, and preparation is required to reduce the rejection rate.

20.
Environ Sci Pollut Res Int ; 30(13): 38052-38062, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36576618

RESUMO

Previous studies have extensively explored impacts of trace elements on human beings and complex relationships with cancers. However, contradictory conclusions may be more challenging to explain due to biological specimen differences. To investigate the distribution of trace elements inside body, we collected serum, whole blood and tissues from 77 patients with esophageal squamous cell carcinoma (ESCC), as well as serum and whole blood from 100 healthy individuals, and determined the concentrations of 13 elements (Al, V, Cr, Mn, Co, Ni, Cu, Zn, As, Se, Sr, Cd, and Pb) with inductively coupled plasma-mass spectrometry (ICP-MS). Al, Ni, Cu, Sr, and Cd variations between patients and controls were found to be inconsistent in serum and blood. Concentrations of Cu, As, Se, and Sr in serum were positively correlated with that in whole blood in both case and control group (rs >0.450, P <0.01). Elements in serum had a higher accuracy (87.0%) than whole blood (74.0%) in classifying ESCC patients and healthy individuals with discriminant analysis. As, Cd, and Pb concentrations in cancerous tissues were positively correlated with those in normal epithelium (rs =0.397, 0.571, and 0.542, respectively), while Mn, Cu, and Se accumulated in malignant tissues, with V, Cr, Co, Ni, Sr, and Cd partitioning in normal epithelium (all P <0.05). Thus, certain elements in blood, such as Cu, As, Se, and Sr, were useful in assessing element exposure burdens and accumulation tendency of some elements (Mn, Cu and Se, etc.) was uncovered in tumors. Our investigation demonstrated the variations in trace element distribution for frequently used specimens and further evidence of etiological mechanism is necessary.


Assuntos
Neoplasias Esofágicas , Carcinoma de Células Escamosas do Esôfago , Oligoelementos , Humanos , Oligoelementos/análise , Cádmio , Chumbo
SELEÇÃO DE REFERÊNCIAS