Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 501
Filtrar
1.
J Clin Monit Comput ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38954170

RESUMO

This pilot study aimed to investigate the relation between cardio-respiratory parameters derived from Central Venous Pressure (CVP) waveform and Extubation Failure (EF) in mechanically ventilated ICU patients during post-extubation period. This study also proposes a new methodology for analysing these parameters during rest/sleep periods to try to improve the identification of EF. We conducted a prospective observational study, computing CVP-derived parameters including breathing effort, spectral analyses, and entropy in twenty critically ill patients post-extubation. The Dynamic Warping Index (DWi) was calculated from the respiratory component extracted from the CVP signal to identify rest/sleep states. The obtained parameters from EF patients and patients without EF were compared both during arbitrary periods and during reduced DWi (rest/sleep). We have analysed data from twenty patients of which nine experienced EF. Our findings may suggest significantly increased respiratory effort in EF patients compared to those successfully extubated. Our study also suggests the occurrence of significant change in the frequency dispersion of the cardiac signal component. We also identified a possible improvement in the differentiation between the two groups of patients when assessed during rest/sleep states. Although with caveats regarding the sample size, the results of this pilot study may suggest that CVP-derived cardio-respiratory parameters are valuable for monitoring respiratory failure during post-extubation, which could aid in managing non-invasive interventions and possibly reduce the incidence of EF. Our findings also indicate the possible importance of considering sleep/rest state when assessing cardio-respiratory parameters, which could enhance respiratory failure detection/monitoring.

2.
Ann Intensive Care ; 14(1): 105, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963533

RESUMO

Infusion of fluids is one of the most common medical acts when resuscitating critically ill patients. However, fluids most often are given without consideration of how fluid infusion can actually improve tissue perfusion. Arthur Guyton's analysis of the circulation was based on how cardiac output is determined by the interaction of the factors determining the return of blood to the heart, i.e. venous return, and the factors that determine the output from the heart, i.e. pump function. His theoretical approach can be used to understand what fluids can and cannot do. In his graphical analysis, right atrial pressure (RAP) is at the center of this interaction and thus indicates the status of these two functions. Accordingly, trends in RAP and cardiac output (or a surrogate of cardiac output) can provide important guides for the cause of a hemodynamic deterioration, the potential role of fluids, the limits of their use, and when the fluid is given, the response to therapeutic interventions. Use of the trends in these values provide a physiologically grounded approach to clinical fluid management.

4.
Am J Med Sci ; 2024 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-38834139

RESUMO

BACKGROUND: The aim of this study was to investigate the optimal CVP range in sepsis and septic shock patients admitted to intensive care unit. METHODS: We performed a retrospective study with adult sepsis patients with CVP records based on the eICU Collaborative Research Database. Multivariable logistic regression was performed to explore the associations between CVP level and hospital mortality. Non-linear correlations and optimal CVP range were explored using restricted cubic splines (RCS). RESULTS: A total of 5302 sepsis patients were included in this study. Patients in 4-8 mmHg group owned the lowest odds ratio for raw hospital mortality (19.7%). The logistic regression analyses revealed that hospital death risk increased significantly when mean CVP level exceeds 12 mmHg compared to 4-8 mmHg level. U-shaped association of CVP with hospital mortality was revealed by RCS model in septic shock patients and the optimal range was 5.6-12 mmHg. While, there was a J-shaped trend for non-septic shock patients. For non-septic shock patients, patients had an increased risk of hospital death only if CVP exceeded 11 mmHg. CONCLUSIONS: We observed U-shaped association between mean CVP level and hospital mortality in septic shock patients and J-shaped association in non-septic shock patients. This may imply that patients with different severity of sepsis have different CVP requirements. We need to monitor and manage CVP according to the circulatory status of the sepsis patient.

5.
Cardiol Young ; : 1-6, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38752303

RESUMO

INTRODUCTION: Acute kidney injury is associated with worse outcomes after cardiac surgery. The haemodynamic goals to ameliorate kidney injury are not clear. Low post-operative renal perfusion pressure has been associated with acute kidney injury in adults. Inadequate oxygen delivery may also cause kidney injury. This study evaluates pressure and oximetric haemodynamics after paediatric cardiac surgery and their association with acute kidney injury. MATERIALS AND METHODS: Retrospective case-control study at a children's hospital. Patients were < 6 months of age who underwent a Society of Thoracic Surgery-European Association for Cardio-Thoracic Surgery Congenital Heart Surgery categories ≥ 3. Low renal perfusion pressure was time and depth below several tested thresholds. The primary outcome was serum creatine-defined acute kidney injury in the first 7 days. RESULTS: Sixty-six patients (median age 8 days) were included. Acute kidney injury occurred in 36%. The time and depth of renal perfusion pressure < 42 mmHg in the first 24 hours was greater in acute kidney injury patients (94 versus 35 mmHg*minutes of low renal perfusion pressure/hour, p = 0.008). In the multivariable model, renal perfusion pressure < 42 mmHg was associated with acute kidney injury (aOR: 2.07, 95%CI: 1.25-3.82, p = 0.009). Mean arterial pressure, central venous pressure, and measures of inadequate oxygen delivery were not associated with acute kidney injury. CONCLUSION: Periods of low renal perfusion pressure (<42 mmHg) in the first 24 post-operative hours are associated with acute kidney injury. Renal perfusion pressure is a potential modifiable target that may mitigate the impact of acute kidney injury after paediatric cardiac surgery.

6.
Langenbecks Arch Surg ; 409(1): 160, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758232

RESUMO

PURPOSE: Intraoperative bleeding during hepatectomy is primarily controlled through anaesthesiological interventions or surgical techniques such as Pringle maneuver (PM). Infrahepatic IVC clamping (IIVCC) is an alternative surgical technique to reduce central venous pressure and prevent retrograde hepatic venous bleeding. The aim of the meta-analysis was to compare IIVCC+PM with PM alone in terms of intraoperative outcomes and perioperative complications. METHODS: Medline, Cochrane Library, Scopus, Web of Science, and EMBASE were searched for comparative studies till 16.04.2024, resulting in 679 articles, of which eight studies met inclusion criteria. Data on patient demographics, surgical technique, and perioperative outcomes was assessed. Cochrane Risk of Bias 2.0 (RoB 2.0) Tool and Newcastle-Ottawa Scale (NOS) were used for risk of bias assessment. RESULTS: Two randomized controlled trials, one prospective, and five retrospective cohort studies with 358 patients in IIVCC+PM and 397 patients in PM alone group were included. IIVCC+PM resulted in significantly greater CVP reduction, less intraoperative blood loss (MD (95% CI) = - 233.03 (- 360.48 to - 105.58), P < 0.001), and less intraoperative blood transfusion (OR (95% CI) = 0.38 (0.25 to 0.57), P < 0.001) compared to PM alone. The two groups had comparable total operative time, transection time and total intraoperative fluid infusion. Patients undergoing IIVCC+PM had significantly shorter length of stay (MD (95% CI) = - 0.63 days (- 1.21 to - 0.05 days), P = 0.03) and overall complication rates (OR (95% CI) = 0.63 (0.43-0.92), P = 0.02) compared to PM alone group. CONCLUSION: The utilization of IIVCC along with PM during liver resection may be beneficial in reducing intraoperative bleeding and blood transfusion without adversely influencing operative times or perioperative outcomes compared to PM alone.


Assuntos
Perda Sanguínea Cirúrgica , Hepatectomia , Veia Cava Inferior , Hepatectomia/métodos , Hepatectomia/efeitos adversos , Humanos , Veia Cava Inferior/cirurgia , Perda Sanguínea Cirúrgica/prevenção & controle , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Constrição , Duração da Cirurgia
7.
World J Cardiol ; 16(5): 221-225, 2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38817642

RESUMO

In this editorial we comment on the article by Kuwahara et al, published in the recent issue of the World Journal of Cardiology. In this interesting paper, the authors showed a correlation between portal vein pulsatility ratio, examined by bedside ultrasonography, and prognosis of hospitalized patients with acute heart failure. Systemic congestion is being notoriously underdetected in the acutely ill population with conventional methods like clinical examination, biomarkers, central venous pressure estimation and X-rays. However, congestion should be a key therapeutic target due to its deleterious effects to end organ function and subsequently patient prognosis. Doppler flow assessment of the abdominal veins is gaining popularity worldwide, as a valuable tool in estimating comprehensively congestion and giving a further insight into hemodynamics and patient management.

8.
J Cardiothorac Surg ; 19(1): 262, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654307

RESUMO

BACKGROUND: The relationship between venous congestion in cardiopulmonary bypass (CPB) and acute kidney injury (AKI) in cardiac surgery has not utterly substantiated. This study aimed at investigate the relationship between CVP in CPB and the occurrence of AKI. METHODS: We retrospectively reviewed 2048 consecutive patients with cardiovascular disease undergoing cardiac procedure with CPB from January 2018 to December 2022. We used the median CVP value obtained during CPB for our analysis and patients were grouped according to this parameter. The primary outcomes were AKI and renal replacement therapy(RRT). Multivariable logistic regression was used to explore the association between CVP and AKI. RESULTS: A total of 2048 patients were enrolled in our study and divided into high CVP group (CVP ≥ 6.5 mmHg) and low CVP group (CVP < 6.5 mmHg) according to the median CVP value. Patients in high CVP group had the high AKI and RRT rate when compared to the low CVPgroup[(367/912,40.24%)vs.(408/1136,35.92%),P = 0.045;(16/912,1.75%vs.9/1136;0.79%), P = 0.049]. Multivariate logistic regression analysis displayed CVP played an indispensable part in development of renal failure in surgical. CONCLUSIONS: Elevated CVP(≥ 6.5mmH2OmmHg) in CPB during cardiac operation is associated with an increased risk of AKI in cardiovascular surgery patients. Clinical attention should be paid to the potential role of CVP in predicting the occurrence of AKI.


Assuntos
Injúria Renal Aguda , Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Pressão Venosa Central , Humanos , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/fisiopatologia , Masculino , Feminino , Ponte Cardiopulmonar/efeitos adversos , Estudos Retrospectivos , Pressão Venosa Central/fisiologia , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Idoso , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Terapia de Substituição Renal
9.
BMC Anesthesiol ; 24(1): 128, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575875

RESUMO

BACKGROUND: Elevated central venous pressure (CVP) is deemed as a sign of right ventricular (RV) dysfunction. We aimed to characterize the echocardiographic features of RV in septic patients with elevated CVP, and quantify associations between RV function parameters and 30-day mortality. METHODS: We retrospectively reviewed a cohort of septic patients with CVP ≥ 8 mmHg in a tertiary hospital intensive care unit. General characteristics and echocardiographic parameters including tricuspid annular plane systolic excursion (TAPSE), pulmonary vascular resistance (PVR) as well as prognostic data were collected. Associations between RV function parameters and 30-day mortality were assessed using Cox regression models. RESULTS: Echocardiography was performed in 244 septic patients with CVP ≥ 8 mmHg. Echocardiographic findings revealed that various types of abnormal RV function can occur individually or collectively. Prevalence of RV systolic dysfunction was 46%, prevalence of RV enlargement was 34%, and prevalence of PVR increase was 14%. In addition, we collected haemodynamic consequences and found that prevalence of systemic venous congestion was 16%, prevalence of RV-pulmonary artery decoupling was 34%, and prevalence of low cardiac index (CI) was 23%. The 30-day mortality of the enrolled population was 24.2%. In a Cox regression analysis, TAPSE (HR:0.542, 95% CI:0.302-0.972, p = 0.040) and PVR (HR:1.384, 95% CI:1.007-1.903, p = 0.045) were independently associated with 30-day mortality. CONCLUSIONS: Echocardiographic findings demonstrated a high prevalence of RV-related abnormalities (RV enlargement, RV systolic dysfunction and PVR increase) in septic patients with elevated CVP. Among those echocardiographic parameters, TAPSE and PVR were independently associated with 30-day mortality in these patients.


Assuntos
Sepse , Disfunção Ventricular Direita , Humanos , Pressão Venosa Central , Ventrículos do Coração/diagnóstico por imagem , Estudos Retrospectivos , Ecocardiografia , Hipertrofia Ventricular Direita , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita , Volume Sistólico
10.
World J Cardiol ; 16(2): 73-79, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38456073

RESUMO

Point-of-care ultrasound (POCUS) of the internal jugular vein (IJV) offers a non-invasive means of estimating right atrial pressure (RAP), especially in cases where the inferior vena cava is inaccessible or unreliable due to conditions such as liver disease or abdominal surgery. While many clinicians are familiar with visually assessing jugular venous pressure through the internal jugular vein, this method lacks sensitivity. The utilization of POCUS significantly enhances the visualization of the vein, leading to a more accurate identification. It has been demonstrated that combining IJV POCUS with physical examination enhances the specificity of RAP estimation. This review aims to provide a comprehensive summary of the various sonographic techniques available for estimating RAP from the internal jugular vein, drawing upon existing data.

11.
Intensive Care Med Exp ; 12(1): 31, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512544

RESUMO

BACKGROUND: The individual components of mechanical ventilation may have distinct effects on kidney perfusion and on the risk of developing acute kidney injury; we aimed to explore ventilatory predictors of acute kidney failure and the hemodynamic changes consequent to experimental high-power mechanical ventilation. METHODS: Secondary analysis of two animal studies focused on the outcomes of different mechanical power settings, including 78 pigs mechanically ventilated with high mechanical power for 48 h. The animals were categorized in four groups in accordance with the RIFLE criteria for acute kidney injury (AKI), using the end-experimental creatinine: (1) NO AKI: no increase in creatinine; (2) RIFLE 1-Risk: increase of creatinine of > 50%; (3) RIFLE 2-Injury: two-fold increase of creatinine; (4) RIFLE 3-Failure: three-fold increase of creatinine; RESULTS: The main ventilatory parameter associated with AKI was the positive end-expiratory pressure (PEEP) component of mechanical power. At 30 min from the initiation of high mechanical power ventilation, the heart rate and the pulmonary artery pressure progressively increased from group NO AKI to group RIFLE 3. At 48 h, the hemodynamic variables associated with AKI were the heart rate, cardiac output, mean perfusion pressure (the difference between mean arterial and central venous pressures) and central venous pressure. Linear regression and receiving operator characteristic analyses showed that PEEP-induced changes in mean perfusion pressure (mainly due to an increase in CVP) had the strongest association with AKI. CONCLUSIONS: In an experimental setting of ventilation with high mechanical power, higher PEEP had the strongest association with AKI. The most likely physiological determinant of AKI was an increase of pleural pressure and CVP with reduced mean perfusion pressure. These changes resulted from PEEP per se and from increase in fluid administration to compensate for hemodynamic impairment consequent to high PEEP.

12.
Crit Care Explor ; 6(4): e1063, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38533295

RESUMO

OBJECTIVES: Examine the: 1) relative role of hemodynamic determinants of acute kidney injury (AKI) obtained in the immediate postcardiac surgery setting compared with established risk factors, 2) their predictive value, and 3) extent mediation via central venous pressure (CVP) and mean arterial pressure (MAP). DESIGN: Retrospective observational study. The main outcome of the study was moderate to severe AKI, per kidney disease: improving global outcomes, within 14 days of surgery. SETTING: U.S. academic medical center. PATIENTS: Adult patients undergoing cardiac surgery between January 2000 and December 2019 (n = 40,426) in a single U.S.-based medical center. Pulmonary artery catheter measurements were performed at a median of 102 minutes (11, 132) following cardiopulmonary bypass discontinuation. INTERVENTIONS: None. MEASUREMENTS AND RESULTS: The median age of the cohort was 67 years (58, 75), and 33% were female; 70% had chronic hypertension, 29% had congestive heart failure, and 3% had chronic kidney disease. In a multivariable model, which included comorbidities and traditional intraoperative risk factors, CVP (p < 0.0001), heart rate (p < 0.0001), cardiac index (p < 0.0001), and MAP (p < 0.0001), were strong predictors of AKI, and superseded factors such as surgery type and cardiopulmonary bypass duration. The cardiac index had a significant interaction with heart rate (p = 0.026); a faster heart rate had a differentiating effect on the relationship of cardiac index with AKI, where a higher heart rate heightened the risk of AKI primarily in patients with low cardiac output. There was also significant interaction observed between CVP and MAP (p = 0.009); where the combination of elevated CVP and low MAP had a synergistic effect on AKI incidence. CONCLUSIONS: Hemodynamic factors measured within a few hours of surgery showed a strong association with AKI. Furthermore, determinants of kidney perfusion, namely CVP and arterial pressure are interdependent; as are constituents of stroke volume, that is, cardiac output and heart rate.

13.
J Clin Monit Comput ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512359

RESUMO

Transpulmonary pressure (PL) calculation requires esophageal pressure (PES) as a surrogate of pleural pressure (Ppl), but its calibration is a cumbersome technique. Central venous pressure (CVP) swings may reflect tidal variations in Ppl and could be used instead of PES, but the interpretation of CVP waveforms could be difficult due to superposition of heartbeat-induced pressure changes. Thus, we developed a digital filter able to remove the cardiac noise to obtain a filtered CVP (f-CVP). The aim of the study was to evaluate the accuracy of CVP and filtered CVP swings (ΔCVP and Δf-CVP, respectively) in estimating esophageal respiratory swings (ΔPES) and compare PL calculated with CVP, f-CVP and PES; then we tested the diagnostic accuracy of the f-CVP method to identify unsafe high PL levels, defined as PL>10 cmH2O. Twenty patients with acute respiratory failure (defined as PaO2/FiO2 ratio below 200 mmHg) treated with invasive mechanical ventilation and monitored with an esophageal balloon and central venous catheter were enrolled prospectively. For each patient a recording session at baseline was performed, repeated if a modification in ventilatory settings occurred. PES, CVP and airway pressure during an end-inspiratory and -expiratory pause were simultaneously recorded; CVP, f-CVP and PES waveforms were analyzed off-line and used to calculate transpulmonary pressure (PLCVP, PLf-CVP, PLPES, respectively). Δf-CVP correlated better than ΔCVP with ΔPES (r = 0.8, p = 0.001 vs. r = 0.08, p = 0.73), with a lower bias in Bland Altman analysis in favor of PLf-CVP (mean bias - 0.16, Limits of Agreement (LoA) -1.31, 0.98 cmH2O vs. mean bias - 0.79, LoA - 3.14, 1.55 cmH2O). Both PLf-CVP and PLCVP correlated well with PLPES (r = 0.98, p < 0.001 vs. r = 0.94, p < 0.001), again with a lower bias in Bland Altman analysis in favor of PLf-CVP (0.15, LoA - 0.95, 1.26 cmH2O vs. 0.80, LoA - 1.51, 3.12, cmH2O). PLf-CVP discriminated high PL value with an area under the receiver operating characteristic curve 0.99 (standard deviation, SD, 0.02) (AUC difference = 0.01 [-0.024; 0.05], p = 0.48). In mechanically ventilated patients with acute respiratory failure, the digital filtered CVP estimated ΔPES and PL obtained from digital filtered CVP represented a reliable value of standard PL measured with the esophageal method and could identify patients with non-protective ventilation settings.

14.
Anaesth Crit Care Pain Med ; 43(3): 101370, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38462160

RESUMO

BACKGROUND: In the intensive care unit (ICU) patients, fluid overload and congestion are associated with worse outcomes. Because of the heterogeneity of ICU patients, we hypothesized that there may exist different endotypes of congestion. The aim of this study was to identify endotypes of congestion and their association with outcomes. METHODS: We conducted an unsupervised hierarchical clustering analysis on 145 patients admitted to ICU to identify endotypes. We measured several parameters related to clinical context, volume status, filling pressure, and venous congestion. These parameters included NT-proBNP, central venous pressure (CVP), the mitral E/e' ratio, the systolic/diastolic ratio of hepatic veins' flow velocity, the mean diameter of the inferior vena cava (IVC) and its variations, stroke volume changes following passive leg raising, the portal vein pulsatility index, and the venous renal impedance index. RESULTS: Three distinct endotypes were identified: (1) "hemodynamic congestion" endotype (n = 75) with moderate alterations of ventricular function, increased CVP and left filling pressure values, and moderate fluid overload; (2) "volume overload congestion" endotype (n = 50); with normal cardiac function and filling pressure despite high positive fluid balance (fluid overload); (3) "systemic congestion" endotype (n = 20) with severe alterations of left and right ventricular functions, increased CVP and left ventricular filling pressure values. These endotypes vary significantly in ICU admission reasons, acute kidney injury rates, mortality, and length of ICU/hospital stay. CONCLUSIONS: Our analysis revealed three unique congestion endotypes in ICU patients, each with distinct pathophysiological features and outcomes. These endotypes are identifiable through key ultrasonographic characteristics at the bedside. CLINICAL TRIAL GOV: NCT04680728.


Assuntos
Pressão Venosa Central , Unidades de Terapia Intensiva , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Pressão Venosa Central/fisiologia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/fisiopatologia , Hemodinâmica , Cuidados Críticos , Análise por Conglomerados , Hiperemia/fisiopatologia , Volume Sistólico , Resultado do Tratamento , Tempo de Internação/estatística & dados numéricos
15.
J Cardiol ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38401702

RESUMO

BACKGROUND: Elevated central venous pressure (CVP) and decreased arterial oxygen saturation (SaO2) are the characteristics of patients after Fontan operations and determine morbidity and mortality in the long-term. Oxygen inhalation therapy theoretically increases SaO2 and may decrease the elevated CVP in these patients. However, there is no previous study to support this hypothesis. This study aimed to determine the acute effects of oxygen inhalation on the hemodynamics of adult patients late after Fontan operations using cardiac catheterization. METHODS: This study enrolled 58 consecutive adult patients (median age, 30 years; female, n = 24) who had undergone Fontan operations. We assessed the hemodynamic changes during oxygen inhalation (2 L/min) with a nasal cannula in cardiac catheterization. We divided the studied patients into two groups according to the reduction in CVP during oxygen inhalation using the median value: responders (>2 mmHg) and non-responders (≤2 mmHg). Clinical characteristics of the responders to oxygen inhalation were investigated with uni- and multivariate analyses. RESULTS: SaO2 increased from 93.3 % (91.3-94.5 %) to 97.5 % (95.2-98.4 %) (p < 0.001) and CVP decreased from 12 mmHg (11-14 mmHg) to 10 mmHg (9-12 mmHg) (p < 0.001) after oxygen inhalation. There was a weak but significant correlation between the increase in SaO2 and the decrease in CVP (R = 0.29, p = 0.025). Pulmonary blood flow increased from 4.1 L/min (3.5-5.0 L/min) to 4.4 L/min (3.7-5.3 L/min) (p = 0.007), while systemic blood flow showed no significant changes. A multivariate analysis revealed that high baseline CVP was associated with a larger decrease in CVP (>2 mmHg) after oxygen inhalation. CONCLUSIONS: Oxygen inhalation increased SaO2 and decreased CVP, especially in patients with high baseline CVP. Further studies with home oxygen therapy are needed to investigate the long-term effects of oxygen inhalation in adult patients who underwent Fontan operations.

16.
Jpn J Nurs Sci ; 21(3): e12589, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38351461

RESUMO

AIMS: The aim of this study was to research the effect of different bed head angles on the hemodynamic parameters of intensive care patients lying in the supine position. METHODS: This study was a non-randomized and non-controlled, quasi-experimental repeated measures study. The study was conducted with 50 intensive care patients aged 18 and over in a general surgery intensive care unit in Turkey. With each patient in the supine position, the bed head was raised to an angle of 0°, 20°, 30°, and 45° without a pillow, and the hemodynamic parameters of central venous pressure, systolic and diastolic blood pressure, heart rate, breathing rate, and peripheral oxygen saturation were recorded after 0 and 10 min. RESULTS: It was found that the mean central venous pressure value measured at min 0 and 10 was higher when the intensive care patients' bed head angle was raised to 45° than when the bed head was at an angle of 0° or 20° (p < .05). It was found that the patients' other hemodynamic parameters were not affected by different bed head angles. CONCLUSIONS: It was concluded as a result of this research that in intensive care patients in the supine position, only central venous pressure was affected by bed head angle, and that central venous pressure measurement can be reliably made at a bed head angle of 30°.


Assuntos
Hemodinâmica , Humanos , Decúbito Dorsal/fisiologia , Masculino , Hemodinâmica/fisiologia , Feminino , Pessoa de Meia-Idade , Adulto , Turquia , Leitos , Idoso , Unidades de Terapia Intensiva , Cuidados Críticos , Posicionamento do Paciente , Cabeça/fisiologia
17.
Ann Hepatobiliary Pancreat Surg ; 28(2): 115-124, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38361339

RESUMO

To compare the outcomes of low central venous pressure (CVP) to standard CVP during laparoscopic liver resection. The study design was a systematic review following the PRISMA statement standards. The available literature was searched to identify all studies comparing low CVP with standard CVP in patients undergoing laparoscopic liver resection. The outcomes included intraoperative blood loss (primary outcome), need for blood transfusion, mean arterial pressure, operative time, Pringle time, and total complications. Random- effects modelling was applied for analyses. Type I and type II errors were assessed by trial sequential analysis (TSA). A total of 8 studies including 682 patients were included (low CVP group, 342; standard CVP group, 340). Low CVP reduced intraoperative blood loss during laparoscopic liver resection (mean difference [MD], -193.49 mL; 95% confidence interval [CI], -339.86 to -47.12; p = 0.01). However, low CVP did not have any effect on blood transfusion requirement (odds ratio [OR], 0.54; 95% CI, 0.28-1.03; p = 0.06), mean arterial pressure (MD, -1.55 mm Hg; 95% CI, -3.85-0.75; p = 0.19), Pringle time (MD, -0.99 minutes; 95% CI, -5.82-3.84; p = 0.69), operative time (MD, -16.38 minutes; 95% CI, -36.68-3.39; p = 0.11), or total complications (OR, 1.92; 95% CI, 0.97-3.80; p = 0.06). TSA suggested that the meta-analysis for the primary outcome was not subject to type I or II errors. Low CVP may reduce intraoperative blood loss during laparoscopic liver resection (moderate certainty); however, this may not translate into shorter operative time, shorter Pringle time, or less need for blood transfusion. Randomized controlled trials with larger sample sizes will provide more robust evidence.

18.
Intensive Care Med Exp ; 12(1): 4, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38224398

RESUMO

BACKGROUND: We have previously reported a simple correction method for estimating pleural pressure (Ppl) using central venous pressure (CVP). However, it remains unclear whether this method is applicable to patients with varying levels of intravascular volumes and/or chest wall compliance. This study aimed to investigate the accuracy of our method under different conditions of intravascular volume and chest wall compliance. RESULTS: Ten anesthetized and paralyzed pigs (43.2 ± 1.8 kg) were mechanically ventilated and subjected to lung injury by saline lung lavage. Each pig was subjected to three different intravascular volumes and two different intraabdominal pressures. For each condition, the changes in the esophageal pressure (ΔPes) and the estimated ΔPpl using ΔCVP (cΔCVP-derived ΔPpl) were compared to the directly measured change in pleural pressure (Δd-Ppl), which was the gold standard estimate in this study. The cΔCVP-derived ΔPpl was calculated as κ × ΔCVP, where "κ" was the ratio of the change in airway pressure to the change in CVP during the occlusion test. The means and standard deviations of the Δd-Ppl, ΔPes, and cΔCVP-derived ΔPpl for all pigs under all conditions were 7.6 ± 4.5, 7.2 ± 3.6, and 8.0 ± 4.8 cmH2O, respectively. The repeated measures correlations showed that both the ΔPes and cΔCVP-derived ΔPpl showed a strong correlation with the Δd-Ppl (ΔPes: r = 0.95, p < 0.0001; cΔCVP-derived ΔPpl: r = 0.97, p < 0.0001, respectively). In the Bland-Altman analysis to test the performance of the cΔCVP-derived ΔPpl to predict the Δd-Ppl, the ΔPes and cΔCVP-derived ΔPpl showed almost the same bias and precision (ΔPes: 0.5 and 1.7 cmH2O; cΔCVP-derived ΔPpl: - 0.3 and 1.9 cmH2O, respectively). No significant difference was found in the bias and precision depending on the intravascular volume and intraabdominal pressure in both comparisons between the ΔPes and Δd-Ppl, and cΔCVP-derived ΔPpl and Δd-Ppl. CONCLUSIONS: The CVP method can estimate the ΔPpl with reasonable accuracy, similar to Pes measurement. The accuracy was not affected by the intravascular volume or chest wall compliance.

19.
J Magn Reson Imaging ; 59(5): 1809-1817, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37427759

RESUMO

BACKGROUND: In clinical practice, the right heart filling status is assessed using the respirophasic variation of the inferior vena cava (IVC) assessed by transthoracic echocardiography (TTE) showing moderate correlations with the catheter-based reference standard. PURPOSE: To develop and validate a similar approach using MRI. STUDY TYPE: Prospective. POPULATION: 37 male elite cyclists (mean age 26 ± 4 years). FIELD STRENGTH/SEQUENCE: Real-time balanced steady-state free-precession cine sequence at 1.5 Tesla. ASSESSMENT: Respirophasic variation included assessment of expiratory size of the upper hepatic part of the IVC and degree of inspiratory collapse expressed as collapsibility index (CI). The IVC was studied either in long-axis direction (TTE) or using two transverse slices, separated by 30 mm (MRI) during operator-guided deep breathing. For MRI, in addition to the TTE-like diameter, IVC area and major and minor axis diameters were also assessed, together with the corresponding CIs. STATISTICAL TESTS: Repeated measures ANOVA test with Bonferroni correction. Intraclass correlation coefficient (ICC) and Bland-Altman analysis for intrareader and inter-reader agreement. A P value <0.05 was considered statistically significant. RESULTS: No significant differences in expiratory IVC diameter were found between TTE and MRI, i.e., 25 ± 4 mm vs. 25 ± 3 mm (P = 0.242), but MRI showed a higher CI, i.e., 76% ± 14% vs. 66% ± 14% (P < 0.05). As the IVC presented a noncircular shape, i.e., major and minor expiratory diameter of 28 ± 4 mm and 21 ± 4 mm, respectively, the CI varied according to the orientation, i.e., 63% ± 27% vs. 75% ± 16%, respectively. Alternatively, expiratory IVC area was 4.3 ± 1.1 cm2 and showed a significantly higher CI, i.e., 86% ± 14% than diameter-based CI (P < 0.05). All participants showed a CI >50% with MRI versus 35/37 (94%) with TTE. ICC values ranged 0.546-0.841 for MRI and 0.545-0.704 for TTE. CONCLUSION: Assessment of the respirophasic IVC variation is feasible with MRI. Adding this biomarker may be of particular use in evaluating heart failure patients. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Imagem Cinética por Ressonância Magnética , Veia Cava Inferior , Humanos , Masculino , Adulto Jovem , Adulto , Veia Cava Inferior/diagnóstico por imagem , Estudos Prospectivos , Ecocardiografia , Coração
20.
Asian J Surg ; 47(1): 477-485, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37438153

RESUMO

BACKGROUND: In the 21st century, 13% of patients undergoing open abdominal surgery, 25% of patients undergoing heart surgery, and 57% of patients admitted to the intensive care unit (ICU) are affected by acute kidney injury (AKI). METHODS: This prospective observational study included patients admitted directly to the ICU between June 2021 and December 2021. RESULTS: A total of 81 patients were enrolled after thoracic and abdominal (non-cardiac) surgery; 36 patients (44.4%) were diagnosed with AKI occurred within 7 days after surgery. Six-hour postoperative central venous pressure(CVP) was a risk factor for AKI in thoracic and abdominal (non-cardiac) postoperative patients (odds ratio [OR], 1.418; 95% confidence intervals [CI], 1.106-1.819; P = 0.006). Six-hour postoperative vein impedance index(VII) and CVP were significantly positively correlated (P = 0.031). The combination of 6-h postoperative VII with CVP (VII ≥0.34, CVP ≥7.5 mmHg) showed an area under the curve (AUC) of 0.787, In the subgroup analysis of patients with 6-h postoperative CVP <7.5 mmHg, there was a significant statistical difference in 6-h postoperative VII between the groups and those without AKI (P = 0.048). At 6-h postoperative CVP <7.5 mmHg, VII of ≥0.44 had a predictive value for AKI after thoracic and abdominal (non-cardiac) surgery, with an AUC of 0.669, a sensitivity of 41.2%, and a specificity of 94.4%. CONCLUSION: Six-hour postoperative CVP combined with VII can better predict the occurrence of AKI occurred within 7 days after thoracic and abdominal (non-cardiac) surgery but cannot predict the severity of AKI.


Assuntos
Injúria Renal Aguda , Procedimentos Cirúrgicos Cardíacos , Humanos , Abdome/cirurgia , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/epidemiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Pressão Venosa Central , Impedância Elétrica , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...