Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Rural Med ; 16(3): 148-153, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34239626

RESUMO

Objectives: To examine the efficacy and clinical and radiological outcomes of the use of a streamlined clavicle plate® (MEIRA, Aichi, Japan) for midshaft clavicular fractures. Methods: This was a retrospective cohort study of 155 patients with displaced midshaft clavicular fractures treated using a streamlined clavicle plate between 2015 and 2019 in 18 hospitals across Japan. A questionnaire regarding bone union and postoperative complications was used, and 136 cases were followed up for one year or until bone union. Plate fitting was evaluated retrospectively using surgical records, radiographic findings, and surgeon's opinion. Results: During surgery, plate bending was needed in 19 cases (12.3%), poor fitting was observed in 8 cases (5.2%), and bone union was achieved in 133 cases (97.8%). Total implantation failure, including plate breakage and screw loosening, occurred in 10 cases (6.5%) from the intraoperative to postoperative period. Subjective complications were observed in 26 cases (16.8%): incongruity around the surgical scar or in the anterior chest in 23, and contracture of the shoulder in three. Plate removal was performed in 66 cases (48.5%) per patient's request. Conclusion: The use of a streamlined clavicle plate is effective for midshaft fractures of the clavicle, and the success rates of bone union and implantation using this approach are comparable to those of other existing plates.

2.
Eur J Trauma Emerg Surg ; 47(5): 1411-1416, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32078702

RESUMO

INTRODUCTION: This study evaluated the optimal anatomical locking plate position using three-dimensional printed models of the clavicle. MATERIALS AND METHODS: Three-dimensional models of the fractured clavicle were reproduced from seventeen patients who underwent minimally invasive plate osteosynthesis (MIPO) procedures. The fracture location-the percentage of the distal fragment length compared to the entire clavicle-ranged from 30-44%. We evaluated four commercially available plate systems for position and fitting with the bone. After reducing the fracture on each three-dimensional model, we determined the optimal plate and its position. RESULTS: The anatomical plate fitted well when positioned in the middle of the clavicle for a fracture location ranging from 40 to 60%. When the fracture location was 30-40%, the anatomical plate fit well onto the bone model only in 36% of clavicles; otherwise, the reversed position of the anatomical plate or the lateral plate fit well. The anatomical plate was found to be unsuitable when the fracture location was less than 30%; in this case, the lateral plate was the best fit. CONCLUSION: Fitting the anatomical plate in MIPO for clavicle fractures depends on the fracture location. This can help surgeons determine the optimal plate for clavicle MIPO.


Assuntos
Clavícula , Fraturas Ósseas , Placas Ósseas , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Impressão Tridimensional , Resultado do Tratamento
3.
Journal of Rural Medicine ; : 148-153, 2021.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-887225

RESUMO

Objectives: To examine the efficacy and clinical and radiological outcomes of the use of a streamlined clavicle plate® (MEIRA, Aichi, Japan) for midshaft clavicular fractures.Methods: This was a retrospective cohort study of 155 patients with displaced midshaft clavicular fractures treated using a streamlined clavicle plate between 2015 and 2019 in 18 hospitals across Japan. A questionnaire regarding bone union and postoperative complications was used, and 136 cases were followed up for one year or until bone union. Plate fitting was evaluated retrospectively using surgical records, radiographic findings, and surgeon’s opinion.Results: During surgery, plate bending was needed in 19 cases (12.3%), poor fitting was observed in 8 cases (5.2%), and bone union was achieved in 133 cases (97.8%). Total implantation failure, including plate breakage and screw loosening, occurred in 10 cases (6.5%) from the intraoperative to postoperative period. Subjective complications were observed in 26 cases (16.8%): incongruity around the surgical scar or in the anterior chest in 23, and contracture of the shoulder in three. Plate removal was performed in 66 cases (48.5%) per patient’s request.Conclusion: The use of a streamlined clavicle plate is effective for midshaft fractures of the clavicle, and the success rates of bone union and implantation using this approach are comparable to those of other existing plates.

4.
J Shoulder Elbow Surg ; 28(10): 1877-1885, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31272891

RESUMO

BACKGROUND: The purpose of this study was to measure the distance of the clavicle in 3 dimensions (3D) and each direction (anterior to posterior, medial to lateral, and superior to inferior) and to analyze the correlation of the angular orientation of the scapula according to each directional distance of the clavicle. METHODS: Sixty-seven patients with Robinson 2B1 and 2B2 clavicle midshaft fracture (46.0 ± 17.4 years, men = 50, women = 17) were selected as final subjects. Patients' computed tomography was reconstructed using an image processing program (3D Slicer 4.3 software). Anteroposterior (AP) distance, medial-to-lateral distance, superior-to-inferior distance, and 3D distance of both clavicles were measured. The plane connecting the 3 points (superior pole, inferior pole, and center of glenoid) of the scapula was used to calculate differences in the angular orientation between both scapulae. RESULTS: Among each directional distance of the clavicle, only the AP distance showed negative correlation with scapular angular orientation with anterior tilting, internal rotation, and upward rotation of the scapula (Pearson's correlation coefficient: -0.68, -0.24, and -0.28; P < .001, P = .048, and P = .021). CONCLUSION: The shortening of the AP distance of the clavicle was related to the angular orientation of the scapula in acute clavicle fracture. AP shortening should be considered when determining the treatment of clavicle fracture.


Assuntos
Clavícula/diagnóstico por imagem , Clavícula/lesões , Fraturas Ósseas/diagnóstico por imagem , Escápula/diagnóstico por imagem , Adulto , Diáfises/lesões , Feminino , Fraturas Ósseas/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Rotação , Escápula/fisiopatologia , Tomografia Computadorizada por Raios X
5.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-650475

RESUMO

PURPOSE: To retrospectively compare minimally invasive percutaneous plate osteosynthesis (MIPPO) with open plate fixation for the treatment of clavicle midshaft fracture. MATERIALS AND METHODS: Between November 2011 to May 2014, 40 cases that were followed for more than 1 year–among all cases of MIPPO and open plate fixation–were analyzed. The study population was divided into two groups: group A included 20 cases of MIPPO and group B included 20 open plate fixation cases. The comparative analysis between the two groups was based on the operative time, bone union, functional evaluation (American Shoulder and Elbow Society score), incision length, pain relief (visual analogue scale, VAS), and complication. RESULTS: The bone union was successful for all the cases, and the functional evaluation scores of the shoulder joint were satisfactory for both groups (p>0.05). The operative time was 47.5 minutes and 58.7 minutes for group A and B, respectively (p<0.05). The incision length for group A was 6.2 cm and that for group B was 10.7 cm with statistical significance (p<0.05). Pain relief (VAS) after surgery for group A showed a quick recuperation in the early stages. For complications, there were 2 cases of dysesthesia and 1 case of malunion due to metal fixation failure in group A. There were 6 cases of dysesthesia and 2 cases of cosmetic problem due to hypertrophic scar in group B. CONCLUSION: Surgical results of clavicle shaft fracture were satisfactory for both groups, but group A had advantages of shorter operative time, minimal incision length, and better pain relief in the early stages compared with group B. However, we need further evaluations with long-term follow-up results and complications, such as malunion and exposure on radiation.


Assuntos
Cicatriz Hipertrófica , Clavícula , Cotovelo , Seguimentos , Duração da Cirurgia , Parestesia , Estudos Retrospectivos , Ombro , Articulação do Ombro