Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 225
Filtrar
1.
Clin Ophthalmol ; 18: 1655-1666, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38863679

RESUMO

Purpose: To evaluate and compare the effect of femtosecond laser-assisted cataract surgery on corneal astigmatism in post-LASIK eyes and virgin eyes. Patients and Methods: Patients who underwent femtosecond laser-assisted cataract surgery were included in the study and categorized into two groups: Group A, consisting of patients with post-LASIK eyes, and Group B, consisting of patients with virgin eyes. Visual acuity, corneal astigmatism, and surgically induced astigmatism (SIA) were evaluated. Additionally, the correlation between SIA and preoperative corneal astigmatism, mean corneal curvature, and central corneal thickness was also analyzed. Results: A total of 168 eyes were enrolled in this study, with 62 eyes in Group A and 106 eyes in Group B. Significant differences in corneal astigmatism and SIA were observed between the two groups in the early postoperative period following cataract surgery (P<0.05). However, there was no significant difference at 6 months postoperatively (P>0.05). Corneal astigmatism demonstrated an against-The-rule shift in both groups postoperatively. No significant correlation was identified between SIA and preoperative corneal astigmatism, corneal curvature or corneal thickness. Additionally, there was no significant difference observed between the two groups in terms of uncorrected distance visual acuity (UDVA) at 6 months postoperatively. Conclusion: The effect of femtosecond laser-assisted cataract surgery on corneal astigmatism in post-LASIK eyes and virgin eyes was different in the early postoperative period. However, there was no significant difference at 6 months postoperatively. The post-LASIK eyes exhibited a delayed recovery compared to the virgin eyes.

2.
Cureus ; 16(4): e58356, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38756279

RESUMO

We experienced a case of bilateral corneal thinning during the oral taking of S-1, a combination anti-cancer drug of tegafur, gimeracil, and oteracil-potassium. A 69-year-old man was prescribed oral S-1 for the treatment of duodenal papilla adenocarcinoma and intraductal papillary mucinous neoplasm. However, he developed a decrease in visual acuity in both eyes after three cycles of S-1 oral taking, and ophthalmic examination revealed corneal thinning exceeding 100 µm and an increase in high-order irregularity of cornea in both eyes. After one month after discontinuation of S-1, his visual acuity and corneal thickness returned to its previous levels. Besides corneal ulcers and perforations, corneal thinning can be recognized as a potential corneal side effect necessitating monitoring during S-1 treatment.

3.
Clin Exp Ophthalmol ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741026

RESUMO

BACKGROUND: To compare results from different corneal astigmatism measurement instruments; to reconstruct corneal astigmatism from the postimplantation spectacle refraction and toric intraocular lens (IOL) power; and to derive models for mapping measured corneal astigmatism to reconstructed corneal astigmatism. METHODS: Retrospective single centre study involving 150 eyes treated with a toric IOL (Alcon SN6AT, DFT or TFNT). Measurements included IOLMaster 700 keratometry (IOLMK) and total keratometry (IOLMTK), Pentacam keratometry (PK) and total corneal refractive power in 3 and 4 mm zones (PTCRP3 and PTCRP4), and Aladdin keratometry (AK). Regression-based models mapping the measured C0 and C45 components (Alpin's method) to reconstructed corneal astigmatism were derived. RESULTS: Mean C0 components were 0.50/0.59/0.51 dioptres (D) for IOLMK/PK/AK; 0.2/0.26/0.31 D for IOLMTK/PTCRP3/PTCRP4; and 0.26 D for reconstructed corneal astigmatism. All corresponding C45 components ranged around 0. The prediction models had main diagonal elements lower than 1 with some crosstalk between C0 and C45 (nonzero off-diagonal elements). Root-mean-squared residuals were 0.44/0.45/0.48/0.51/0.50/0.47 D for IOLMK/IOLMTK/PK/PTCRP3/PTCRP4/AK. CONCLUSIONS: Results from the different modalities are not consistent. On average IOLMTK/PTCRP3/PTCRP4 match reconstructed corneal astigmatism, whereas IOLMK/PK/AK show systematic C0 offsets of around 0.25 D. IOLMTK/PTCRP3/PTCRP4. Prediction models can reduce but not fully eliminate residual astigmatism after toric IOL implantation.

4.
Ophthalmol Ther ; 13(6): 1743-1755, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38662192

RESUMO

INTRODUCTION: Dry eye can compromise corneal astigmatism measurement repeatability during preoperative cataract surgery examination. No previous studies have analyzed the effectiveness of long-acting 3% diquafosol sodium (LA-DQS) on astigmatism measurement repeatability. This research assessed the effect of LA-DQS on astigmatism measurement repeatability in preoperative patients with cataract and short tear break-up time (TBUT) type dry eyes in both eyes of the same patient. Correlations between repeatability and TBUT, corneal high-order aberrations (HOAs), and corneal astigmatism magnitude were also analyzed. METHODS: In total, 122 eyes (61 patients) with short TBUT-type dry eye were enrolled. Preoperatively, only one eye of all patients was treated with LA-DQS for 4 weeks. TBUT and corneal HOAs were checked using CASIA 2 before and 4 weeks post-treatment. The cylindrical power and meridian of astigmatism were measured at 3- and 4-week post-treatment using IOLMaster 700. Power vectors J0 and J45 were used for astigmatism calculations. Repeatability of astigmatism measurements was assessed as the within-subject standard deviation (Sw). The relative effects of TBUT and HOAs on J0 Sw and J45 Sw were also analyzed. Comparative changes in these variables were evaluated between treated and non-treated eyes, with additional analysis of their correlations. RESULTS: Treated eyes exhibited significant improvements in TBUT, HOAs, and post-treatment measurements of J0 Sw and J45 Sw at 3 and 4 weeks. In non-treated eyes, J0 Sw and J45 Sw showed significant correlation with TBUT and corneal HOAs. HOAs showed stronger relative associations with J0 Sw and J45 Sw than TBUT. In non-treated eyes, no significant correlation was found between cylindrical power and astigmatism measurement repeatability. CONCLUSIONS: In short TBUT-type dry eye, preoperative treatment with LA-DQS significantly improved astigmatism measurement repeatability. This may improve the precision of intraocular lens (IOL) power calculations regardless of the magnitude of corneal astigmatism, especially when toric IOLs are used.

5.
Ophthalmol Ther ; 13(7): 1877-1889, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38581606

RESUMO

INTRODUCTION: This study is a retrospective case series to compare the accuracy of the Barrett toric calculator using predicted posterior corneal astigmatism (PCA) and PCA measurements using swept-source optical coherence tomography (SS-OCT) and a Scheimpflug camera. This evaluation was conducted across different types of anterior and posterior astigmatism. METHODS: A total of 146 eyes from 146 patients implanted with toric intraocular lenses were included. Mean absolute prediction error, standard deviation of prediction error, and the percentage of eyes with prediction errors within ±0.50 diopters (D) were calculated using vector analysis. Biometric measurements were conducted using the IOLMaster 700 and Pentacam HR. A subgroup analysis was conducted based on the orientation of both anterior and posterior corneal astigmatism. RESULTS: The Barrett toric calculator with predicted PCA yielded the best results, with 78.1% having a prediction error ≤ 0.50 D, which was a significantly higher percentage than the Barrett formula with the two versions of measured PCA (P < 0.05). In the subgroup with a horizontally steep meridian PCA using the IOLMaster 700, the Barrett formula with predicted PCA yielded the best results, with 78.3% of cases having a prediction error of less than 0.5 D. This percentage was significantly higher than the other two measured PCA subgroups (P < 0.05). CONCLUSION: The Barrett toric formula with predicted PCA demonstrated a statistically significantly higher proportion of cases with a prediction error ≤ 0.5 D compared to the two measured PCA formulas (from the IOLMaster 700 or Pentacam). This trend persisted even when the posterior corneal astigmatism was horizontally steep.

6.
Clin Ophthalmol ; 18: 755-763, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476355

RESUMO

Purpose: To evaluate the effectiveness and safety of the AcrySof IQ PanOptix toric intraocular lens (IOL) with cylinder power of 1.0 D (TFNT20) in a Japanese population with low corneal astigmatism and compare with historical control data for nontoric IOLs. Setting: Tokyo Dental College Suidobashi Hospital, Tokyo, Japan. Design: Prospective, single-center study. Methods: Patients ≥20 years old received TFNT20 IOL in at least 1 eye based on Alcon Toric calculator (Holladay Total surgically induced astigmatism). Effectiveness endpoints included the percentage of eyes with refractive cylinder ≤0.25 D at 30-60 days after surgery, which was compared with a historical control threshold rate of 29.2% for nontoric IOLs and refractive cylinder ≤0.50 D. Monocular uncorrected distance visual acuity (UDVA; 5 m), uncorrected intermediate visual acuity (UIVA; 60 cm), uncorrected near visual acuity (UNVA; 40 cm), and adverse events were evaluated. Results: Of 41 eyes implanted with TFNT20 IOLs, 37 eyes (90%) achieved refractive cylinder ≤0.25 D at 30-60 days after surgery, demonstrating the superiority of TFNT20 compared with historical data (P<0.0001). Refractive cylinder of ≤0.50 D was achieved by 41 eyes (100%). At 30-60 days, mean ± SD monocular CDVA was -0.15 ± 0.07 logMAR, UDVA was -0.09 ± 0.09 logMAR, UIVA was -0.00 ± 0.07 logMAR, and UNVA was 0.03 ± 0.07 logMAR. Six eyes (15%) had elevated postoperative intraocular pressure, which returned to normal and was not device-related. Conclusion: TFNT20 IOLs successfully reduced postoperative refractive cylinder and provided good distance, intermediate, and near uncorrected VAs in Japanese patients with low corneal astigmatism.

7.
Children (Basel) ; 11(2)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38397266

RESUMO

This study explores whether children's refractive errors and visual behaviors reverted to pre-COVID-19 levels a year after normal schooling resumed in Hong Kong as well as the impact of corneal and internal astigmatism on refractive astigmatism development. Vision survey data and questionnaire results collected in 2022 (n = 119) and 2020 (n = 173) were compared. Cross-sectional data showed similar proportions of astigmatism (cylindrical power ≥ 0.75 D) in the 2020 (49.1%) and 2022 cohorts (55.5%). Despite a 0.28 D increase in corneal astigmatism, a compensatory 0.24 D increase in internal astigmatism of opposite direction kept refractive astigmatism relatively stable. The questionnaire data showed that children spent an additional 0.5 h/day outdoors on weekends post-resumption of normal schooling but engaged in more near-work activities, especially non-screen near-work, by approximately 1 h/day on both weekdays and weekends. These findings were supported by longitudinal data from 72 children who participated in both surveys. This study highlights the significant role of corneal and internal astigmatism in refractive astigmatism changes. Despite the return to in-person classes, children's total near-work time increased and astigmatism remained high. These findings underscore the need for comprehensive strategies to reduce the high environmental risks for refractive error development in children.

8.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 133-141, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37470808

RESUMO

PURPOSE: Corneal scars after infectious keratitis lead to insufficient transparency and irregular astigmatism, affecting visual acuity; therefore, they should be accurately evaluated to estimate visual function. This study aimed to quantitatively evaluate corneal irregularity and scarring after infectious keratitis using anterior segment optical coherence tomography (AS-OCT). METHODS: This was an observational clinical study. We included patients who had corneal scarring after treatment of infectious keratitis between 2014 and 2021 at University of Tokyo Hospital. We retrospectively examined best spectacle-corrected visual acuity (BSCVA), average keratometric power, central corneal thickness (CCT), and four components of the Fourier harmonic analysis including spherical and asymmetry components, as well as regular astigmatism and higher-order irregularity. We included anterior and posterior corneal data and compared results with those of contralateral healthy eyes. Additionally, we quantitatively evaluated the densitometry of the cornea obtained using AS-OCT. RESULTS: A total of 122 eyes of 61 patients were examined; male predominance was observed (n = 37), and the mean patient age was 55.3 ± 19.4 years. Comparisons with contralateral healthy eyes showed that BSCVA worsened (0.30 ± 0.83 and 0.93 ± 1.36 logMAR, respectively, P = 0.003), and CCT (531.1 ± 46.2 and 591.8 ± 132.4 µm, respectively, P < 0.001) and corneal densitometry (84.4 ± 11.8 and 111.9 ± 19.2 grayscale units, respectively, P < 0.001) increased significantly in affected eyes. The asymmetry component and higher-order irregularities that were not corrected with spectacles significantly increased (both P < 0.001), and there were no significant differences in the changes among the bacterial, fungal, herpetic, and acanthamoeba types of keratitis. CONCLUSION: Corneal scarring persisted after treatment for infectious keratitis, and the asymmetry and irregularities of corneal astigmatism increased as visual acuity deteriorated. AS-OCT with the Fourier harmonic analysis was useful for evaluating corneal topographic changes in patients with corneal scarring after keratitis.


Assuntos
Astigmatismo , Lesões da Córnea , Ceratite , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Tomografia de Coerência Óptica/métodos , Cicatriz/patologia , Astigmatismo/patologia , Estudos Retrospectivos , Córnea/patologia , Topografia da Córnea , Lesões da Córnea/patologia
9.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 249-260, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37552315

RESUMO

PURPOSE: The scientific community has established Javal's rule as a model linking refractive (RA) and keratometric (KA) astigmatism since its appearance more than 100 years ago. The aim was to improve the accuracy of this relationship according to subject's age by applying the power vector analysis. Posterior corneal curvature has also been studied. METHODS: The IOLMaster 700 optical biometer was used to measure the corneal thickness and the radius of curvature of the anterior and posterior corneal surfaces. Refractive error was determined by a non-cycloplegic subjective refraction process with trial lenses. Linear regression analyses were applied using J0 and J45 power vector components. An evaluation was carried out according to the subject's age resulting into eight regression relationships for each astigmatic vector component for each relationship. RESULTS: A total of 2254 right eyes from 2254 healthy subjects were evaluated. A trend towards against-the-rule astigmatism (ATR) was found with aging, both for refractive astigmatism (RA) and keratometric astigmatism (KA), with 95.2% of subjects under 20 years old having with-the-rule (WTR) KA, and only 22.8% above 79 years old. The following regression equations were found between RA and KA: [Formula: see text] = 0.73 × [Formula: see text] - 0.18 (R = 0.78) and [Formula: see text] = 0.70 × [Formula: see text] + 0.04 (R = 0.69) and between RA and total corneal astigmatism (TCA): [Formula: see text] = 0.73 × [Formula: see text] + 0.13 (R=0.78) and [Formula: see text] = 0.70 × [Formula: see text] - 0.06 (R = 0.68) for the whole sample, but with sensible differences among age groups, both in the slope and in the intercept. CONCLUSION: Ignoring the age of the subject when using Javal's rule could lead to an error in the final cylinder calculation that would increase in high astigmatisms. Applying this new power vector approach based on subject's age could improve the accuracy of the astigmatism prediction.


Assuntos
Astigmatismo , Erros de Refração , Humanos , Adulto Jovem , Adulto , Idoso , Astigmatismo/diagnóstico , Erros de Refração/diagnóstico , Refração Ocular , Córnea , Envelhecimento , Topografia da Córnea
10.
Eur J Ophthalmol ; 34(1): 146-153, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37093755

RESUMO

PURPOSE: To evaluate the short-term clinical outcomes of a specific toric diffractive trifocal intraocular lens (IOL) implanted following an optimized clinical protocol in a large population. METHODS: Retrospective analysis of 337 eyes of 231 patients (mean age, 62.2 years) undergoing cataract surgery with implantation of the trifocal diffractive IOL AT.LISA tri toric 939M/MP (Carl Zeiss Meditec). A strict and careful clinical protocol was followed, including an accurate measurement of corneal astigmatism, use of a latest generation IOL power calculator, photography-based method intraoperative control of IOL alignment and IOL reposition at 1 week postoperatively if needed. Clinical outcomes in terms of visual acuity, refraction, efficacy of astigmatic correction analysed by vector analysis and patient satisfaction were evaluated during a 3-month follow-up. RESULTS: A total of 82% and 98% of eyes achieved a postoperative uncorrected distance visual acuity of 0.00 and 0.10 logMAR or better, respectively. Furthermore, 99.7%, and 100.0% of eyes showed a postoperative spherical equivalent within ± 0.50 D and ± 1.00 D, with 97.9% of eyes having a postoperative cylinder ≤ 0.50 D. Uncorrected near and intermediate visual acuities were 0.2 logMAR or better in 89.0% and 99.1% of eyes, respectively. Mean difference vector, magnitude of error and angle of error were 0.02 ± 0.14 D, 0.02 ± 0.13 D and 0.11 ± 1.18°. Patient satisfaction was referred as high or very high by 97.6% of patients. CONCLUSIONS: The implantation of the trifocal toric IOL evaluated following a careful clinical protocol provides an efficacious visual rehabilitation and astigmatic correction, leading to high levels of patient satisfaction.


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Desenho de Prótese , Refração Ocular , Astigmatismo/cirurgia
11.
International Eye Science ; (12): 816-820, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1016602

RESUMO

AIM:To compare the differences of ocular biometric parameters of age-related cataract between Tibetan and Han ethnic groups, and to analyze the distribution characteristics of ocular biometric parameters in Tibetan cataract patients.METHODS:Retrospective cohort study. A total of 661 patients(1 030 eyes)with age-related cataract confirmed in the hospital between January 2019 and December 2020 were enrolled. The parameters of axial length, anterior chamber depth, keratometry, corneal astigmatism and astigmatic axis were measured by IOL Master 500 in 483 cases(739 eyes)of Tibetan age-related cataract patients and 178 cases(291 eyes)of Han patients.RESULTS:The axial length, anterior chamber depth and corneal astigmatism of the Tibetan patients with age-related cataract were 23.33(22.81, 23.86)mm, 3.04(2.79, 3.30)mm and 0.73(0.47, 1.07)D. The mean keratometry was 43.89±1.35 D. The results indicated that Tibetan cataract patients had shorter axial lengths and smaller keratometry compared to Han patients(all P&#x003C;0.05). Age in Tibetan patients was negatively correlated with axial length and anterior chamber depth, and positively correlated with keratometry(all P&#x003C;0.05). Tibetan male patients had longer axial lengths, deeper anterior chambers, and flatter corneas compared to female patients(all P&#x003C;0.05).CONCLUSION:There were differences in ocular biometric parameters between age-related cataract patients of Tibetan and Han ethnicities. The distribution of ocular biometric parameters in Tibetan cataract patients varied across different age groups and gender groups.

12.
International Eye Science ; (12): 500-507, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1012811

RESUMO

AIM: To compare the anterior and posterior corneal astigmatism and total refractive astigmatism before and after MyoRing implantation in keratoconus(KCN)patients.METHODS: In this historical cohort study, the preoperative and postoperative total refractive, anterior and posterior corneal astigmatism of KCN patients implanted with a 360-degree full-ring implant(MyoRing)were compared before and after four consecutive follow-up sessions at 3, 6, 9, and 12 mo after surgery.RESULTS: The study encompassed 79 KCN patients(85 eyes), comprising 43 males and 36 females. The mean age of the patients was 29±7.41 years, ranging from 17 to 48 years. Throughout the follow-up sessions, a gradual decrease was observed in the trend of changes for total refractive astigmatism, anterior corneal astigmatism, and posterior corneal astigmatism. Postoperatively, total refractive astigmatism measurements exhibited a significant decrease of 2.09 D at 12 mo after MyoRing implantation(4.27±3.15 vs 2.18±1.63 D, P&#x003C;0.001). Additionally, post-operative measurements revealed an enhancement of approximately 3.20 D and 0.59 D for anterior and posterior corneal astigmatism, respectively [6.40±1.90 vs 3.20±1.75 D for anterior corneal astigmatism(P&#x003C;0.001)and 1.30±0.55 vs 0.71±0.35 D for posterior corneal astigmatism(P&#x003C;0.001)].CONCLUSION: MyoRing implantation demonstrates significant improvements in astigmatism parameters, encompassing total refractive astigmatism as well as anterior and posterior corneal astigmatism.

13.
International Eye Science ; (12): 463-468, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1011402

RESUMO

AIM: To evaluate the convenience and accuracy of a novel smartphone-assisted “any-point two-step method” for finding the target axial position in cataract phacoemulsification combined with intraocular lens(IOL)implantation.METHODS: Prospective observational study. A total of 62 cases(62 eyes)of patients with age-related cataracts who underwent cataract phacoemulsification combined with IOL implantation in our hospital from October 2021 to April 2022 were selected. They were randomly divided into two groups: 31 cases(31 eyes)in the control group were applied with the “traditional two-step method” using slit lamp to mark the target axial position of the IOL, and 31 cases(31 eyes)in the experimental group were applied with the smartphone-assisted “two-step method” to mark the target axial position of the IOL. The Callisto eye navigation system was used as a standard reference, and the deviation of the reference marking point(deviation-1), the deviation of the target axial marking point(deviation-total), and the deviation of the angle from the reference marking point to the target axial marking point(deviation-2)were calculated and recorded as the preoperative axial marking time.RESULTS:Both deviation-1 and deviation-total values were lower in the experimental group than those in the control group(1.06°±1.39° vs 2.48°±2.23°, 1.77°±1.54° vs 2.81°±1.58°, all P&#x003C;0.01), but there was no significant difference in the deviation-2 values between the two groups(1.35°±1.40° vs 1.48°±1.79°, P&#x003E;0.05). The preoperative axial marking took shorter time in the experimental group than in the control group(1.77±1.70 min vs 2.88±3.20 min, P&#x003C;0.01).CONCLUSION: The smartphone-assisted “any-point two-step method” for finding the target axial position in cataract phacoemulsification combined with IOL implantation is simple, time-saving, and accurate compared with the “traditional two-step method”.

14.
Eur J Ophthalmol ; : 11206721231210895, 2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37919941

RESUMO

PURPOSE: Evaluate the agreement between IOL Master 500 (Carl Zeiss Meditec AG, Germany) and MYAH (Topcon EU, Visia Imaging, Japan) in measuring axial length, keratometry, and anterior corneal astigmatism. SETTING: Department of Biomedical and Dental Sciences and Morphofunctional Imaging, Ophthalmology Clinic, University of Messina, Messina, Italy. METHODS: In this prospective study, 40 eyes (right eye 25, left eye 15) of 40 patients were included. Axial length (AL), keratometry (K1, K2), and anterior corneal astigmatism (ACA) were measured. AL, mean K (Kavg) and magnitude of ACA were compared using Bland - Altman plot analysis, parametric and nonparametric statistical analysis. The difference vector and angle of error of the ACA measured by the two devices were evaluated by vector analysis using polar diagrams. RESULTS: Mean and standard deviation with IOL Master and with MYAH device was for AL 24.25 ± 1.22 mm and 24.25 ± 1.22 mm (p = .99), for Kavg 42.75 ± 1.53 D and 42.85 ± 1.52 D (p = .78), for Magnitude of ACA 1.00 ± 0.58 D and 0.89 ± 0.56 D (p = .38) respectively. High correlations were found for AL (R² = 0.999), Kavg (R² = 0.996), and ACA Magnitude (R² = 0.889). Bland-Altman analysis of the two devices found high agreement and absence of proportional bias (MYAH-IOL MASTER) were found between the two assessments for AL (bias = -0.0005 mm, p = .93), Kavg (bias = 0.0955 D, p = .76) and ACA (bias = 0.11 D, p = .41). Limit of agreement (upper/lower LoA, 95%CI) were respectively +0.057/-0.058 mm for AL, + 0.29/-0.09 D for Kavg and +0.49/-0.27 D for ACA. No statistical difference was found between the x-component and y-component of the ACA vector (p > .01), the difference vector (IOL MASTER-MYAH) was +0.14 D axis 159 with an absolute mean angle of error of 7.2 ± 7.5 degree. CONCLUSIONS: The instruments appear to be interchangeable for measurements of AL, keratometry, and magnitude of ACA with high agreement between the two devices. Also, in the presence of low astigmatism, the two instruments give the same results in terms of ACA.

15.
BMC Ophthalmol ; 23(1): 449, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37950161

RESUMO

BACKGROUND: To investigate the prevalence and risk factors of refractive astigmatism (RA) and corneal astigmatism (CA) in preschool children and school-aged children in Shanghai, China. METHODS: In this school-based, cross-sectional study, 4-15 years old children across three learning stages of kindergarten, primary school, and junior high school underwent noncycloplegic autorefraction and completed comprehensive questionnaires involving time spent on daily homework and outdoor activities. Data from the right eyes were analysed. RESULTS: Overall, 7084 children (mean ± standard deviation (SD) of age: 8.08 ± 3.11 years) were included, and the prevalence rates of RA/CA ( ≤ - 1.0 D) in children were 15.8%/64% in kindergartens, 16.5%/65% in primary schools, and 32.8%/76.9% in junior high schools. The magnitude and prevalence of RA and CA all increased with age or with learning stage (all P < 0.001). The presence of RA was associated with more myopic spherical power (odds ratio (OR) 0.956, P = 0.021), junior high school (OR 1.973, P < 0.001), longer homework time on weekdays (OR 1.074, P = 0.029), and shorter outdoor activity time on weekends (odds ratio 0.929, P = 0.013). CONCLUSION: In the wide age range of 4 to 15 years, the magnitude and prevalence of RA and CA increased with the learning stage, and these increases mainly began at the primary school stage. Factors, including longer homework time and shorter outdoor time were correlated with the presence of RA.


Assuntos
Astigmatismo , Doenças da Córnea , Pré-Escolar , Humanos , Criança , Adolescente , Astigmatismo/epidemiologia , Astigmatismo/complicações , Prevalência , Estudos Transversais , População do Leste Asiático , China/epidemiologia , Refração Ocular , Doenças da Córnea/complicações , Fatores de Risco
16.
Int J Ophthalmol ; 16(10): 1692-1701, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37854386

RESUMO

AIM: To investigate the research trend on refractive cataract surgery, compare the contributions of different countries, institutions, journals, and authors in the past 20y, and explore its potential research hotspots. METHODS: All publications were extracted relating to refractive cataract surgery from 2003 to 2022 from Web of Science. Document types were limited to original articles and reviews, and the language was limited to English. Quantitatively and qualitatively of the publications were analyzed through Microsoft Excel and GraphPad Prism. VOSviewer and CiteSpace were used for bibliometric and visualized analysis. RESULTS: A total of 2090 publications were enrolled. The United States contributed the most publications (434, 20.8%), followed by China (345, 16.5%) and England (163, 7.80%). Publications from the United States were cited more frequently (9552 citations) with the highest H-index of 48. China ranked second in the total number of publications, the papers were not cited that frequently (3237 citations), and the H-index ranked sixth (H-index=29). Journal of Cataract and Refractive Surgery published the most papers (333, 15.9%), and the University of London had the highest number of publications (75, 3.59%). Dick HB from Germany published the most papers. Corneal astigmatism-related research, cataract surgery method-related research, postoperative visual-quality relate to research, and postoperative complications-relate research are the hotspots in this field. The most significant limitation was that the database was updated frequently and the latest publications were not included. CONCLUSION: The bibliometric analysis shows a brief summarization of the contribution of the authors, institutions, countries, and journals. Corneal astigmatism, cataract surgery method, postoperative visual-quality and postoperative complications related researches have become the emerging hotspots, which can give a direction in the future researches.

17.
Clin Ophthalmol ; 17: 2983-2996, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37841901

RESUMO

Purpose: We evaluate the reduction of corneal astigmatism and the improvement of visual outcomes of this surgical method in the Indonesian population. We also assess the accuracy and predictability of using femtosecond laser astigmatic keratotomy (FLAK) combined with cataract surgery. Patients and Methods: In a retrospective study, a total of 275 subjects (78 with against-the-rule (ATR) astigmatism, 178 with with-the-rule (WTR) astigmatism, and 19 with oblique (OBL) astigmatism) with preexisting corneal astigmatism ranging from 0.75D to 3.00D underwent FLAK. All subjects completed a 3-month follow-up. The femtosecond laser used for creating paired AK 2.2 mm, primary incision, and paracentesis incision was the FEMTO Z8 NEO from Ziemer Ophthalmic System, Switzerland. The surgical approach was guided by the "NAPA" nomogram. Results: The reduction in postoperative astigmatism was 56.90% for the WTR group, 49.46% for the ATR group, and 47.33% for the oblique group. A significant reduction in astigmatism was observed at the 1-week, 1-month, and 3-month follow-up intervals in both the WTR and ATR groups. The reduction in astigmatism was more favorable in cases of moderate astigmatism within the WTR group, as compared to the ATR and oblique groups. Postoperative astigmatism reduction was found to be more predictable in the right eye than in the left eye. Conclusion: The combination of FLAK can be considered as a potential method for reducing corneal astigmatism ranging from 1.00D to <3.00D. The highest reduction was observed in the WTR group, along with a higher rate of intended correction without astigmatism meridian shift in the right eye for the WTR group. However, factors such as cyclotorsion resulting from the surgical technique, alignment of docking, incision length, and preoperative astigmatism need to be taken into account for further enhancement and predictability of astigmatism reduction with this method.

18.
Adv Ophthalmol Pract Res ; 3(1): 39-46, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37846431

RESUMO

Purpose: To investigate the influence of posterior corneal astigmatism on the prediction accuracy of toric multifocal intraocular lens (IOL) calculation. Methods: The keratometric astigmatism measured by Lenstar LS 900 (KCAL), keratometric astigmatism (KCAP) and total corneal astigmatism (TCA) measured by Scheimpflug camera (Pentacam HR) were documented and analyzed accordingly. Three deduction models using different parameters were compared. Model 1: KCAL â€‹+ â€‹keratometric corneal surgically induced astigmatism (KCSIA, 0.30 D @ 50°); Model 2: KCAP â€‹+ â€‹KCSIA); Model 3: TCA â€‹+ â€‹total CSIA (TCSIA, 0.23 D @ 50°). The prediction errors of each model as the difference vector between the actual and the intended residual astigmatism were compared. Results: Seventy-six eyes implanted with toric multifocal IOLs were included in this study. The vector differences of the actual KCSIA and TCSIA were statistically significant in the total sample and against-the-rule (ATR) subgroup (both P â€‹< â€‹0.05). Model 1 deduced the smallest mean values of prediction error, while that of Model 3 were smaller than that of Model 2, both in the total sample and the ATR subgroups (all P â€‹< â€‹0.05). Meanwhile, in the total sample and ATR subgroups, the centroid vector magnitudes of Model 3 were smaller than that of Model 1 (0.31 â€‹± â€‹0.76 D and 0.39 â€‹± â€‹0.76 D). Conclusions: The calculation of toric multifocal IOL should be individualized especially in the ATR eyes for the impact of PCA on the estimation of the preoperative corneal astigmatism and the CSIA.

19.
Indian J Ophthalmol ; 71(8): 2967-2971, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37530266

RESUMO

Purpose: To evaluate whether the toric intra-ocular lens (IOL) power calculation based on total corneal astigmatism (TCA) in eyes with high posterior corneal astigmatism (PCA) could result in a systematic over-correction or under-correction after operation. Methods: The present study included a mono-centric retrospective study design. The data were collected from 62 consecutive eyes during uncomplicated cataract surgery by a single surgeon with a measured PCA of 0.50 diopters (D) or higher. Toric IOL calculations were made using TCA measurements. The eyes were grouped as either "with-the-rule" (WTR) or "against-the-rule" (ATR) on the basis of the steep anterior corneal meridian. The post-operative refractive astigmatic prediction error was analyzed 1 month post-operatively using the vector analysis by the Alpins method and double-angle plots method. Results: The correction indexes were 1.14 ± 0.29 in the ATR eyes and 1.25 ± 0.18 for the WTR eyes, indicating a tendency toward over-correction. The mean over-correction was 0.22 ± 0.52D in the ATR group and 0.65 ± 0.60D in the WTR group. The magnitude of error (ME) values were significantly different from the ideal value of zero in both groups (ATR: P = 0.03; WTR: P = 0.00). No significant difference in mean absolute error (MAE) in predicted residual astigmatism was found between ATR and WTR groups (0.61 ± 0.42 D versus 0.64 ± 0.39 D; P = 0.54). The ATR group yielded better results, with 48% <0.50D prediction error in the main analysis. Conclusions: The results suggested that in cases of high PCA, the toric IOL calculation, which was performed using TCA, may cause a potential over-correction in the ATR and WTR eyes. For ATR eyes, over-correction led to slight disruption of post-operative visual quality because of the "with-the-rule" residual astigmatism after operation. Therefore, we suggested using TCA for toric IOL calculation in ATR eyes.


Assuntos
Astigmatismo , Doenças da Córnea , Lentes Intraoculares , Facoemulsificação , Humanos , Astigmatismo/diagnóstico , Astigmatismo/cirurgia , Implante de Lente Intraocular , Estudos Retrospectivos , Topografia da Córnea , Facoemulsificação/métodos , Refração Ocular , Doenças da Córnea/cirurgia
20.
Int J Ophthalmol ; 16(8): 1231-1236, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37602351

RESUMO

AIM: To evaluate the postoperative intraocular lens (IOL) rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL. METHODS: In this retrospective case series, 32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter (D). A plate haptic toric IOL (AT Torbi 709M, Carl Zeiss Meditec AG) was implanted in all eyes. The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity (BCVA). RESULTS: Preoperative refractive astigmatism was 2.14±1.17 D, which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period (0.67±0.44 D at three months and 0.75±0.25 D at six months; for all groups: P<0.0001 compared to baseline). BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery (P=0.02). Mean IOL axis deviation from the target axis was 3.4°±2.9° after six to eight weeks and significantly decreased over time (2.4°±2.6° six months after surgery; P=0.04). In one patient IOL, re-alignment was performed. CONCLUSION: Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery. The plate haptic toric IOL position and axis remain stable during the observation period of six months.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...