Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
1.
G Ital Nefrol ; 41(4)2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39243417

RESUMO

Cool dialysate has variable impact on hemodynamic stability and dialysis adequacy. Hemodynamic stability and dialysis adequacy are crucial indicators for better life expectancy and cardiovascular mortality. This research aims to evaluate the impact of cool dialysate temperature (35.5°C) compared to standard dialysate temperature (37°C) on blood pressures, pulse rate, and dialysis adequacy (Urea reduction ratio and online Kt/V) in a cross over design. Material and Methods. Consenting ESRD patients on maintenance haemodialysis (HD) with minimum 3 months dialysis vintage and functioning permanent vascular access are included for the study. Each participant had two sessions of HD at 37°C followed by two sessions at 35.5° C on a Fresenius 4008S HD machine. Systolic blood pressure (SBP), diastolic blood pressure (DBP) and Pulse rate are measured pre-HD, every hourly and post dialysis. Pre-HD Blood urea nitrogen (BUN) and post-HD BUN are measured, and Urea reduction rate was calculated for each HD session. Kt/V was calculated by ionic conductance by HD machine for each session. Results. 25 patients (5 females and 20 males) were enrolled. The mean age was 54 ± 9.58 years. Dialysis vintage was 21.48 ± 6.9 months for study participants 10 patients (40%) were diabetic nephropathy, 9 patients (36%) were presumed chronic glomerulonephritis, 2 patients (8%) were lupus nephritis and 4 patients (16%) were chronic interstitial nephritis. There was statistically no difference between pre-HD BUN (p = 0.330), post-HD BUN (p = 0.776), URR (p = 0.718) and Kt/V (p = 0.534) among the dialysis sessions done at 37°C and 35.5°C. SBP variability in the low temperature (35.5°C) group at 4th hour and post dialysis assumed statistical significance with p = 0.05 and p = 0.025 respectively. DBP variability in the low temperature (35.5°C) group at 3rd hour, 4th hour and post-dialysis demonstrated statistical significance with p = 0.027, p = 0.36 and p = 0.016 respectively. Pulse rate variability was more in the low temperature (35.5°C) group at 3rd hour and 4th hour which showed statistical significance with p = 0.037 and p = 0.05 respectively. Conclusion. Cool dialysate is non inferior to standard dialysate temperature in terms of dialysis adequacy and is associated with less variability in diastolic blood pressure, systolic blood pressure and more pulse rate variability thereby contributing to better hemodynamic stability.


Assuntos
Estudos Cross-Over , Hemodinâmica , Falência Renal Crônica , Diálise Renal , Humanos , Feminino , Masculino , Diálise Renal/métodos , Pessoa de Meia-Idade , Falência Renal Crônica/terapia , Falência Renal Crônica/fisiopatologia , Pressão Sanguínea , Soluções para Diálise/química , Soluções para Hemodiálise/química , Temperatura , Frequência Cardíaca , Idoso , Temperatura Baixa , Nitrogênio da Ureia Sanguínea
2.
Indian J Nephrol ; 34(4): 357-362, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39156843

RESUMO

Background: Mild cognitive impairment (MCI) in peritoneal dialysis (PD) patients has been described as a risk factor for worse outcomes such as peritonitis, technique failure, and mortality. In this study, we aimed to determine the prevalence of MCI in a population of PD patients and identify the possible risk factors associated with MCI. Materials and Methods: We performed an observational, cross-sectional study to evaluate cognitive function using the Montreal Cognitive Assessment (MOCA) test and the Mini Mental State Examination (MMSE) test in PD patients. Patients with diagnosis of dementia or severe neurologic impairment, active cancer, or infection were excluded. Results: We evaluated 66 patients (mean age 60 years); 53% were male. Prevalence of MCI assessed by MOCA test and MMSE test was 65% and 33%, respectively. Predictors of MCI with MOCA test were higher age (P = 0.0001), lower education level (P = 0.005), need of a helper (P = 0.009), and continuous ambulatory PD modality (P = 0.019). Higher Charlson comorbidity index (P = 0.002), coronary artery disease (P = 0.006), and peripheral artery disease (P = 0.033) were also associated with MCI. Lower Kt/V (P = 0.012) and lower levels of normalized protein catabolic rate (nPCR; P < 0.000) were related to MCI. MCI patients had more episodes of peritonitis (P = 0.047). Multivariable analysis showed that lower education, Kt/V, and nPCR were the most relevant factors connected to MCI (P = 0.029, P = 0.037, and P = 0.019, respectively). Conclusion: In our PD population, MCI was detected in more than half of the patients. Patients with MCI were older, had lower education level, more disease burden, and higher risk for developing peritonitis. Lower Kt/V and nPCR levels were associated with MCI.

3.
Clin Nutr ESPEN ; 63: 768-775, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39173906

RESUMO

BACKGROUND AND AIMS: Intradialytic eating practices is a subject of debate among hemodialysis patients and is associated with a variety of clinical implications. This study aimed to investigate eating practices during hemodialysis and their influence on health outcome, including various symptoms experienced during dialysis, intradialytic hypotension, dialysis adequacy, and malnutrition. METHODS: A cross-sectional study was conducted on hemodialysis patients. A structured questionnaire was used to collect information related to sociodemographic, medical history, lifestyle, dialysis, and eating practices. The occurrence of intradialytic hypotension was determined according to the patients' blood pressure measured at the beginning and end of the session, and dialysis adequacy was determined based on the ultrafiltration rate of the patients. Malnutrition was evaluated using renal inpatient screening tool (renal iNUT), and biochemical data was recruited from the patient's hospital records. RESULTS: A total of 260 hemodialysis patients participated in this study. The mean age was 51.29 ± 15.92, and half of the participants were females. The findings showed no significant association between intradialytic eating practices and symptoms developed during dialysis session, intradialytic hypotension, or malnutrition (p > 0.05). According to Chi-square test, a statistically significant association was found between eating practices and dialysis adequacy (p = 0.037), hemoglobin level (p < 0.001), and phosphorous level (p = 0.003). CONCLUSION: Eating practices were not associated with symptoms that developed during dialysis sessions, intradialytic hypotension, or malnutrition, according to our findings. However, findings reveal that it is possible that eating practices may affect the adequacy of dialysis.

4.
Int Urol Nephrol ; 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38850394

RESUMO

BACKGROUND: End-stage kidney disease (ESKD) carries a significant financial burden due to the need for hemodialysis (HD). Many HD patients do not achieve optimal dialysis, particularly in developing countries like Indonesia where HD is performed twice a week. To answer this issue, a study was conducted at Dr. Sardjito hospital, Indonesia to investigate the effectiveness of intradialysis aerobic exercise in improving dialysis adequacy and quality of life in conventional HD patients. METHODS: This study is an experimental design with a pre-test-post-test control group. ESKD with HD patient was divided into treatment and control groups. The intervention group was subjected to 30 min of intradialysis aerobic exercise using an ergocycle within the first 2 h of the HD sessions, while the control group received regular care. Both groups were followed for 12 weeks. Dialysis adequacy is measured using Kt/V and Urea Reduction Ratio (URR). Quality of life is assessed using KDQOL-36 questionnaire. RESULTS: There was a significant increase in Kt/V and URR (%) in the intervention group compared to the control group, (0.122 ± 0.151 vs - 0.135 ± 0.176, p < 0.001) and (2.627 ± 4.634 vs - 2.620 ± 3.949, p < 0.001), respectively. In addition, quality of life also improved significantly with KDQOL-36 summary score was significantly higher 73.47 (39.44-89.31) to 80.97 (43.06-92.36); p = 0.007) in the intervention group. Multivariate analysis showed that intradialysis exercise (p = 0.001), female gender (p = 0.044), and intradialysis diastolic pressure (p = 0.018) can significantly affect Kt/V changes. CONCLUSION: Intradialytic aerobic exercise for 12 weeks effectively improves dialysis adequacy and quality of life in routine HD patients. This suggests an opportunity for routine deployment, especially when HD resources are limited. However, further studies are needed to investigate additional efficacy aspects and improve exercise protocols for specific ESKD patients. TRIAL REGISTRATION: TCTR202403270002 (retrospectively registered on March 27, 2024).

5.
Disabil Rehabil ; : 1-10, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38874310

RESUMO

PURPOSE: This study was performed to investigate and compare the effects of intradialytic core stabilization and aerobic exercises on physical performance, fatigue, quality of life and dialysis adequacy. MATERIALS AND METHODS: The study involved 39 individuals on hemodialysis randomized into two groups: aerobic exercise (AE, n = 20) and core stabilization (CSE, n = 19). Over 8 weeks, the AE group performed pedal ergometer exercises, while the CSE group performed 4-phase core stabilization exercises. Physical performance (five times sit to stand test, 2-min step test), quality of life (Kidney Disease Quality of Life-36; KDQOL-36), fatigue levels (Piper Fatigue Scale), and dialysis adequacy (Kt/V and URR) were assessed. RESULTS: After training, a significant improvement was observed in the physical performance, fatigue levels, and some parameters of KDQOL-36 of the patients (p < 0.05). However, no significant changes were observed in dialysis adequacy indicators (Kt/V and URR) (p > 0.05). When the amount of development obtained in both treatment groups is compared, kidney disease burden only in the subparameter of KDQOL-36 was statistically significantly improved in the CSE group compared to the AE group (p < 0.05). CONCLUSIONS: According to the results of the study, intradialytic core stabilization exercises appear to have similar effects to aerobic exercises and can be performed by HD patients.


Core stabilization exercises and aerobic exercises performed during dialysis are well tolerated by hemodialysis patients.Over eight weeks, intradialytic core stabilization and aerobic exercises are effective in improving physical performance, fatigue level, and quality of life in hemodialysis patients.In hemodialysis patients, eight weeks of intradialytic core stabilization and aerobic exercises are not sufficient to improve dialysis adequacy.It is recommended to include intradialytic core stabilization and aerobic exercises in the rehabilitation of hemodialysis patients.

6.
Hemodial Int ; 28(3): 313-325, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38783838

RESUMO

INTRODUCTION: Progressive clogging of the dialyzer membrane during hemodialysis can compromise solute removal efficiency. Existing solutions fall short in addressing intradialytic reduction of dialyzer clearance. This pilot study aims to assess the impact and safety of applying therapeutic ultrasonic waves to dialyzers for mitigating intradialytic clogging. METHODS: In this pilot study, 15 stable maintenance hemodialysis patients (12 males and 3 females) were enrolled. Each patient served as their own control. They underwent one session of hemodialysis with the application of therapeutic ultrasonic waves (Ultrasonic session) and were crossed-over to a second session without the use of ultrasonic waves (Control session). All the study sessions operated at a fixed dialysate flow rate of 500 mL/min and a blood flow rate of 250 or 300 mL/min. The adequacy of dialysis achieved during each session was monitored using Online Clearance Monitoring of the dialysis machines, and clearance K values, varying between 135 and 209 mL/min, were recorded, and plotted. A direct comparison between Control and Ultrasonic sessions was performed to assess the impact and safety of using ultrasonic waves during hemodialysis. FINDINGS: The mean percentage decline in dialyzer clearance values was 4.41% for Ultrasonic sessions (SD: 5.3) and 12.69% for Control sessions (SD: 6.35) (p-value <0.001). This indicates that the application of ultrasonic waves reduced the decline in clearance values. The mean differences of the blood component parameters were comparable between both Ultrasonic sessions and Control sessions, suggesting the safety of utilizing ultrasonic waves during dialysis. Microscopic membrane analysis corroborated the safety. DISCUSSION: Intradialytic clogging of dialyzer membranes is a significant problem that can cause dialysis inadequacy. Our study tackles this issue by introducing therapeutic ultrasonic waves to improve dialyzer clearance during hemodialysis sessions in patients.


Assuntos
Diálise Renal , Humanos , Projetos Piloto , Diálise Renal/métodos , Diálise Renal/instrumentação , Diálise Renal/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Membranas Artificiais , Idoso , Ondas Ultrassônicas , Adulto
7.
Ann Med Surg (Lond) ; 86(5): 2739-2744, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38694348

RESUMO

Background: This study aims to assess the effect of needle distance of arteriovenous fistula (AVF) cannulation on haemodialysis adequacy based on KT/V. Materials and methods: This study was a parallel-group, randomized controlled trial. Patients who met the inclusion criteria were divided into two groups with 3 and 6 cm needle distances using block randomization. Data acquisition transpired through a comprehensive checklist encompassing demographic variables such as age and sex, alongside clinical metrics comprising actual weight, dry weight, average dialysis duration, fistula longevity, and KT/V rate. Results: A total of 42 haemodialysis patients were enroled in this investigation, with 21 allocated to the 3 cm needle distance group and another 21 to the 6 cm needle distance group. The mean post-haemodialysis KT/V values for the 3 cm and 6 cm needle distance groups were 1.25 (SD=0.25) and 1.42 (SD=0.24), respectively, demonstrating a statistically significant difference (P<0.001). While there was no significant difference in the average pre-haemodialysis and post-haemodialysis KT/V values within the 3 cm needle distance group (t=1.93, P=0.068), the corresponding values for the 6 cm needle distance group exhibited a notable discrepancy (t=9.66, P<0.001). Conclusion: In general, a needle distance of 6 cm between arteriovenous points yielded superior enhancements in dialysis adequacy compared to a 3 cm needle distance following haemodialysis. Consequently, health administrators and policymakers may consider instituting efficacious interventions to scrutinize the care and therapeutic protocols for haemodialysis patients, involving the development of policies and applications.

8.
North Clin Istanb ; 10(4): 435-443, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37719249

RESUMO

OBJECTIVE: The aim of this study was to reveal the relationship between hemodialysis (HD) adequacy and dialysis symptom index (DSI) in patients with end-stage kidney disease (ESKD). METHODS: This prospective study included 92 ESKD patients who underwent HD three times a week. Data including sex, age, education status, marital status, economic status, employment status, dependency status, type of vascular access, and duration of HD were recorded. Biochemical and hematological analyses were carried out. Dialysis adequacy was assessed based on clinical and biochemical analysis. The DSI was used to evaluate the emotional and physical symptoms of HD patients. RESULTS: Of the patients, 55 were males and 37 were females, with a mean age of 59.95±14.9 years. The median duration of HD was 60.0 months (interquartile range: 20.8-103.5). The mean DSI score was 54.35±26.0, with a significantly higher score in female patients (p<0.001). There was a significant correlation between DSI and increasing age (p<0.05). The single pool Kt/V (spKt/V) ratio of HD patients with AVF access was significantly higher, and the mean DSI was significantly lower than that of those receiving HD with a central venous catheter (p<0.001). The mean DSI score was significantly higher in patients with a spKt/V ratio of <1.2 than those with a spKt/V ratio of ≥1.2 (p<0.001). In multivariate regression analysis using biochemical parameters, the spKt/V ratio was a significant and independent predictor of DSI scores (R2=0.64, p<0.001). In addition, a significant and independent relationship was found between DSI and gender, age, and economic status in the regression analysis (R2=0.36, p<0.001). CONCLUSION: Dialysis adequacy is an independent predictor of DSI. If an adequate dialysis dose is ensured to be delivered, symptom burden may dramatically decrease.

9.
Clin Kidney J ; 16(7): 1071-1080, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37398691

RESUMO

In recent years there has been an increasing interest in expanded hemodialysis (HDx), an emerging renal replacement therapy based on the use of medium cut-off membranes (MCO). Thanks to the internal architecture of these types of membranes, with a higher pore size and smaller fiber inner diameter to favor internal filtration rate, they can increase the removal of larger middle molecules in conventional hemodialysis. Secondarily, several reports suggest that this therapy potentially improve the outcomes for end-stage renal disease patients. However, HDx has not been defined yet and the characteristics of MCO membranes are not well stablished. The aim of this narrative review is to define HDx and summarize the dialyzers that have been used so far to perform this therapy, collect the evidence available on its efficacy and clinical outcomes compared with other hemodialysis techniques and settle the bases for its optimal prescription.

10.
Medicina (Kaunas) ; 59(6)2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37374218

RESUMO

Background and Objectives: In peritoneal dialysis (PD) therapy, intra-abdominal adhesions (IAAs) can cause catheter insertion failure, poor dialysis function, and decreased PD adequacy. Unfortunately, IAAs are not readily visible to currently available imaging methods. The laparoscopic approach for inserting PD catheters enables direct visualization of IAAs and simultaneously performs adhesiolysis. However, a limited number of studies have investigated the benefit/risk profile of laparoscopic adhesiolysis in patients receiving PD catheter placement. This retrospective study aimed to address this issue. Materials and Methods: This study enrolled 440 patients who received laparoscopic PD catheter insertion at our hospital between January 2013 and May 2020. Adhesiolysis was performed in all cases with IAA identified via laparoscopy. We retrospectively reviewed data, including clinical characteristics, operative details, and PD-related clinical outcomes. Results: These patients were classified into the adhesiolysis group (n = 47) and the non-IAA group (n = 393). The clinical characteristics and operative details had no remarkable between-group differences, except the percentage of prior abdominal operation history was higher and the median operative time was longer in the adhesiolysis group. PD-related clinical outcomes, including incidence rate of mechanical obstruction, PD adequacy (Kt/V urea and weekly creatinine clearance), and overall catheter survival, were all comparable between the adhesiolysis and non-IAA groups. None of the patients in the adhesiolysis group suffered adhesiolysis-related complications. Conclusions: Laparoscopic adhesiolysis in patients with IAA confers clinical benefits in achieving PD-related outcomes comparable to those without IAA. It is a safe and reasonable approach. Our findings provide new evidence to support the benefits of this laparoscopic approach, especially in patients with a risk of IAAs.


Assuntos
Laparoscopia , Diálise Peritoneal , Humanos , Estudos Retrospectivos , Cateteres de Demora , Diálise Renal , Diálise Peritoneal/efeitos adversos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Peritônio
11.
Blood Purif ; 52(7-8): 686-693, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37379824

RESUMO

Chronic kidney disease and end-stage kidney disease (ESKD) are important public health problems with increased rates of morbidity, mortality, and social costs. Pregnancy is rare in patients with ESKD, with reduced fertility rates in women undergoing dialysis. Although current advances have led to an increase in live births in pregnant dialysis patients, this modality still has an increased risk of multiple adverse events in pregnant women. Despite these existing risks, large-scale studies investigating the management of pregnant women on dialysis are lacking, resulting in the absence of consensus guidelines for this patient group. In this review, we aimed to present the effects of dialysis during pregnancy. We first discuss pregnancy outcomes in dialysis patients and the development of acute kidney injury during pregnancy. Then, we discuss our recommendations for the management of pregnant dialysis patients, including the maintenance of pre-dialysis blood urea nitrogen levels, the ideal frequency and duration of hemodialysis sessions, as well as the modality of renal replacement therapies, the difficulty of maintaining peritoneal dialysis in the third trimester of pregnancy, and optimization of prepregnancy modifiable risk factors. Finally, we present our recommendations for future studies investigating dialysis among pregnant patients.


Assuntos
Falência Renal Crônica , Diálise Renal , Humanos , Feminino , Gravidez , Diálise , Falência Renal Crônica/terapia , Resultado da Gravidez , Terapia de Substituição Renal
12.
Clin Kidney J ; 16(4): 735-744, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37007697

RESUMO

Background: Kt/Vurea is the most used marker to estimate dialysis adequacy; however, it does not reflect the removal of many other uraemic toxins, and a new approach is needed. We have assessed the feasibility of estimating intradialytic serum time-averaged concentration (TAC) of various uraemic toxins from their spent dialysate concentrations that can be estimated non-invasively online with optical methods. Methods: Serum and spent dialysate levels and total removed solute (TRS) of urea, uric acid (UA), indoxyl sulphate (IS) and ß2-microglobulin (ß2M) were evaluated with laboratory methods during 312 haemodialysis sessions in 78 patients with four different dialysis treatment settings. TAC was calculated from serum concentrations and evaluated from TRS and logarithmic mean concentrations of spent dialysate (MlnD). Results: Mean (± standard deviation) intradialytic serum TAC values of urea, UA, ß2M and IS were 10.4 ± 3.8 mmol/L, 191.6 ± 48.1 µmol/L, 13.3 ± 4.3 mg/L and 82.9 ± 43.3 µmol/L, respectively. These serum TAC values were similar and highly correlated with those estimated from TRS [10.5 ± 3.6 mmol/L (R 2 = 0.92), 191.5 ± 42.8 µmol/L (R 2 = 0.79), 13.0 ± 3.2 mg/L (R 2 = 0.59) and 82.7 ± 40.0 µmol/L (R 2 = 0.85)] and from MlnD [10.7 ± 3.7 mmol/L (R 2 = 0.92), 191.6 ± 43.8 µmol/L (R 2 = 0.80), 12.9 ± 3.2 mg/L (R 2 = 0.63) and 82.2 ± 38.6 µmol/L (R 2 = 0.84)], respectively. Conclusions: Intradialytic serum TAC of different uraemic toxins can be estimated non-invasively from their concentration in spent dialysate. This sets the stage for TAC estimation from online optical monitoring of spent dialysate concentrations of diverse solutes and for further optimization of estimation models for each uraemic toxin.

13.
Nephrol Nurs J ; 50(2): 123-130, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37074937

RESUMO

End stage kidney disease (ESKD), a public health concern, has overwhelming effects on individuals' holistic wellbeing. Hemodialysis, albeit a life-saving treatment for patients with ESKD, can lead to muscle atrophy, weakness, and decreased quality of life mostly due to an inactive lifestyle. This quasi-experimental, pre-post design was used to study the effects of exercise on physiologic and psychologic outcomes of patients with ESKD at a hemodialysis unit in Lebanon. Patients acted as their own controls and were assessed before and after introducing the exercise program. Data were collected on quality of life of patients as well as their dialysis adequacy. Results showed that while there was a significant improvement in the dialysis adequacy post-exercise intervention, quality of life was not affected.


Assuntos
Falência Renal Crônica , Diálise Renal , Humanos , Diálise Renal/psicologia , Unidades Hospitalares de Hemodiálise , Falência Renal Crônica/terapia , Falência Renal Crônica/psicologia , Exercício Físico , Qualidade de Vida
14.
Ther Apher Dial ; 27(2): 284-292, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36858049

RESUMO

INTRODUCTION: Medium-cut-off (MCO) dialyzers may beneficially impact outcomes in patients on hemodialysis. METHODS: In a randomized, controlled trial in maintenance hemodialysis patients, the new Nipro ELISIO-17HX MCO dialyzer was compared to the Baxter Theranova 400 filter regarding middle molecule removal. Furthermore, the suitability of two assays for free lambda-light chain (λFLC) detection (Freelite vs. N-Latex) was verified. RESULTS: ELISIO-HX achieved slightly lower reduction ratios for ß2 -microglobulin (71.8 ± 6.0 vs. 75.3 ± 5.8%; p = 0.001), myoglobin (54.7 ± 8.6 vs. 64.9 ± 8.7%; p < 0.001), and kappa-FLC (62.1 ± 8.8 vs. 56.3 ± 7.7%; p = 0.021). λFLC reduction ratios were more conclusive with the Freelite assay and not different between ELISIO-HX and Theranova (28.4 ± 3.9 vs. 38.7 ± 13.4%; p = 0.069). The albumin loss of Theranova was considerably higher (2.14 ± 0.45 vs. 0.77 ± 0.25 g; p = 0.001) and the Global Removal ScoreLoss alb largely inferior (30.6 ± 7.4 vs. 82.4 ± 29.2%/g; p = 0.006) to ELISIO-HX. CONCLUSIONS: The new ELISIO-HX expands the choice of dialyzers for MCO hemodialysis.


Assuntos
Albuminas , Cefalosporinas , Diálise Renal , Humanos , Mioglobina , Diálise Renal/instrumentação
15.
J Cereb Blood Flow Metab ; 43(6): 882-892, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36651130

RESUMO

The pathogenesis of cerebral atrophy (CA) is not clear. Previous studies show a high incidence of preterm CA in hemodialysis patients. This study aims to investigate the factors influencing CA and to derive a CA prediction nomogram in maintenance-hemodialysis patients. First, brain volumes of hemodialysis patients (≤55 years) were compared against age- and sex-matched healthy controls, and differences were revealed in bilateral insular cisterns width, maximum cerebral sulci width, Evans index, ventricular-brain ratio, frontal atrophy index, and temporal lobe ratio. Then, the patients were divided equally into "no or mild" or "severe" CA groups. Potential factors influencing CA were screened. Kt/V (urea removal index) and hemoglobin levels negatively correlated with CA degree, and were used to establish a nomogram within randomly assigned training and validation patient groups. The areas under the receiver operating characteristic curves (AUROC) for training and validation groups were 0.703 and 0.744, respectively. When potassium and calcium were added to the nomogram, the AUROC for training/validation group increased to 0.748/0.806. The nomogram had optimal AUROC for training (0.759) and validation (0.804) groups when albumin was also included. Hemodialysis patients showed reduced anterior brain volumes and the nomogram established herein may have predictive value for developing CA.


Assuntos
Diálise Renal , Ureia , Recém-Nascido , Humanos , Atrofia , Hemoglobinas , Estudos Retrospectivos
16.
J Vasc Access ; 24(1): 45-51, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34112001

RESUMO

BACKGROUND AND AIM: HD patients using dialysis catheters have been associated with chronic inflammatory state. In Egypt 6.6% of HD patients use catheters, of which short term catheters represent 59.6% and 40.4% with long-term catheters. In this study, we aimed to assess the effect of Taurolidine citrate and unfractionated heparin combination (Taurolock-hep500™) as a lock solution compared to unfractionated heparin alone on inflammatory markers, incidence of catheter related blood stream infections (CRBSI) and dialysis adequacy in HD patients with temporary HD catheters only, for 4 weeks duration. METHODS: Sixty ESRD patients from hemodialysis units in Ain-Shams University hospitals (ASUH) at the time of catheter insertion we enrolled in our study. They were randomized into two groups: Group 1: Thirty patients received Taurolock-hep500™ as a catheter lock solution at the end of each hemodialysis session. Group 2: Thirty patients received unfractionated heparin as a catheter lock solution. hsCRP and IL-6 were measured at baseline and 1 month after using the lock solutions. Blood cultures were done in patients who developed symptoms of catheter related infections. RESULTS: At the end of the study, Inflammatory markers were significantly higher in group 2 (p-value: 0.045, 0.001, and 0.018 for WBCs, hsCRP and IL-6, respectively). Group 1 had better dialysis adequacy assessed by URR (p-value: 0.007 and 0.001, respectively). CRBSI were demonstrated in nine patients in group 2 (30%) in contrast to one patient only in group 1(3.3%) (p-value: 0.006) with pseudomonas being the most common isolated organism (27.7%). CONCLUSION: Use of (Taurolock-hep500™) for temporary hemodialysis catheters was associated with lower levels of inflammation markers and lower incidence of CRBSI and better catheter performance.


Assuntos
Infecções Relacionadas a Cateter , Cateteres Venosos Centrais , Humanos , Heparina/efeitos adversos , Ácido Cítrico , Proteína C-Reativa , Interleucina-6 , Diálise Renal/efeitos adversos , Citratos , Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/prevenção & controle , Infecções Relacionadas a Cateter/epidemiologia , Inflamação/diagnóstico , Inflamação/etiologia , Anticoagulantes/efeitos adversos
17.
Ther Apher Dial ; 27(3): 464-470, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36263921

RESUMO

BACKGROUND: Recent evidence suggests that automated peritoneal dialysis (APD) might be a feasible alternative to hemodialysis (HD) in urgent-start peritoneal dialysis. METHODS: This prospective study enrolled end-stage renal disease (ESRD) patients who had started APD as an urgent-start dialysis modality at a single center. Dialysis-related complications were recorded. Dialysis adequacy and electrolytes imbalance were compared between baseline, 14 and 42 days after catheter insertion. Technique survival and patient survival were also recorded. RESULTS: A total of 36 patients were included in the study. Mean follow-up duration was 22 months. During the follow-up, 11 PD patients (30.6%) developed dialysis-related complications. Only two patients (5.6%) required re-insertion and one patients (2.8%) transfer to HD. The 2-year technique survival rate and patient survival rate were 94.4% and 97.2%, respectively. CONCLUSION: In considering safety and dialysis adequacy, APD could be a feasible dialysis modality for urgent-start dialysis in ESRD patients, using a standard procedure.


Assuntos
Falência Renal Crônica , Diálise Peritoneal , Humanos , Diálise Renal , Estudos Prospectivos , Fatores de Tempo , Diálise Peritoneal/métodos
18.
Nephrol Dial Transplant ; 38(6): 1508-1518, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-36549655

RESUMO

BACKGROUND: Chronic kidney disease-associated pruritus (CKD-aP) is common in dialysis patients, and is associated with lower quality of life and increased risk of death. We investigated the association between residual estimated glomerular filtration rate (eGFR), dialysis adequacy or serum phosphate level and CKD-aP in incident dialysis patients. METHODS: A total of 1256 incident hemodialysis (HD) and 670 peritoneal dialysis (PD) patients (>18 years) from the Netherlands Cooperative Study on the Adequacy of Dialysis (NECOSAD) study were included (1997-2007) and followed until death, transplantation or a maximum of 10 years. CKD-aP was measured using a single item of the Kidney Disease Quality of Life Instrument-36. The associations were studied by logistic and linear regression analyses, adjusted for potential baseline confounders. RESULTS: At baseline mean (standard deviation) age was 60 (16) years, 62% were men and median (interquartile range) residual eGFR was 3.4 (1.7; 5.3) mL/min/1.73 m2. The prevalence of CKD-aP (∼70%) was similar in HD and PD. It was observed that 12 months after starting dialysis (after multivariable adjustment) each 1 mL/min/1.73 m2 higher residual eGFR, one unit higher total weekly Kt/V, or 1 mmol/L lower serum phosphate level was associated with lower burden of CKD-aP in HD and PD patients of -0.05 (95% CI -0.09; -0.02) and -0.09 (95% CI -0.13; -0.05), -0.15 (95% CI -0.26; -0.05) and -0.35 (95% CI -0.54; -0.16), and of -0.34 (95%CI: -0.51; -0.17) and -0.45 (95%CI: -0.71; -0.19), respectively. We found no association between dialysis Kt/V and CKD-aP. CONCLUSIONS: Higher residual eGFR and lower serum phosphate level, but not the dialysis dose, were related with lower burden of CKD-aP in dialysis patients.


Assuntos
Falência Renal Crônica , Insuficiência Renal Crônica , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Diálise Renal/efeitos adversos , Qualidade de Vida , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/terapia , Rim , Prurido/epidemiologia , Prurido/etiologia , Fosfatos , Falência Renal Crônica/complicações , Falência Renal Crônica/terapia
19.
Turk J Med Sci ; 53(6): 1863-1869, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38813487

RESUMO

Background and aim: There are over 60,000 hemodialysis (HD) patients in Türkiye, and the number of patients is increasing yearly. Dialysate flow rate (Qd) is a factor in HD adequacy. Approximately 150 L of water are consumed per session to prepare the dialysate. We aimed to investigate whether HD effectiveness can be achieved at a low Qd in different patient groups for the purpose of saving water. Materials and methods: This prospective study included 81 HD patients from 2 centers. The patients underwent an aggregate total of 486 HD sessions, including 3 sessions at a Qd of 500 mL/min and 3 sessions at a Qd of 300 mL/min for each patient. We used online Kt/V readings recorded at the end of each dialysis session to compare the effectiveness of these 2 types of HD session performed at a different Qd. Results: The online Kt/V readings were similar between the standard (500) and low (300) Qd HD (1.51 ± 0.41 and 1.49 ± 0.44, respectively, p = 0.069). In the subgroup analyses, men had higher online Kt/V values at the standard Qd compared to the low Qd (1.35 ± 0.30 and 1.30 ± 0.32, respectively, p = 0.019), but the Kt/V values were not different for women. While the low Qd did not reduce online Kt/V in patients using small surface area dialysis membranes (1.75 ± 0.35 for 300 Qd and 1.75 ± 0.32 for 500 Qd, p = 0.931), it was associated with reduced online Kt/V in patients using large surface area dialysis membranes (1.12 ± 0.25 for 300 Qd and 1.17 ± 0.24 for 500 Qd, p = 0.006). The low Qd did not result in differences in online Kt/V among low-weight patients. However, online Kt/V values were better with the standard Qd in patients weighing 65 kg and above. Conclusion: In our study, dialysis adequacy at a reduced dialysate flow was not inferior for women, patients with low body weight, or patients using small surface area membranes. Individualized HD at a reduced Qd of 300 mL/min in eligible patients can save 48 L of water per HD session and an average of 7500 L of water per year.


Assuntos
Diálise Renal , Humanos , Diálise Renal/métodos , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Água , Adulto , Soluções para Diálise , Falência Renal Crônica/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA