RESUMO
The development and application of an electrochemical sensor is reported for detection of poly(3-hydroxybutyrate) (P3HB) - a bioplastic derived from agro-industrial residues. To overcome the challenges of molecular imprinting of macromolecules such as P3HB, this study employed methanolysis reaction to break down the P3HB biopolymer chains into methyl 3-hydroxybutyrate (M3HB) monomers. Thereafter, M3HB were employed as the target molecules in the construction of molecularly imprinted sensors. The electrochemical device was then prepared by electropolymerizing a molecularly imprinted poly (indole-3-acetic acid) thin film on a glassy carbon electrode surface modified with reduced graphene oxide (GCE/rGO-MIP) in the presence of M3HB. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), scanning electron microscopy with field emission gun (SEM-FEG), Raman spectroscopy, attenuated total reflection Fourier-transform infrared (ATR-FTIR) and X-ray Photoelectron Spectroscopy (XPS) were employed to characterize the electrode surface. Under ideal conditions, the MIP sensor exhibited a wide linear working range of 0.1 - 10 nM and a detection limit of 0.3 pM (n = 3). The sensor showed good repeatability, selectivity, and stability over time. For the sensor application, the bioproduction of P3HB was carried out in a bioreactor containing the Burkholderia glumae MA13 strain and sugarcane byproducts as a supplementary carbon source. The analyses were validated through recovery assays, yielding recovery values between 102 and 104%. These results indicate that this MIP sensor can present advantages in the monitoring of P3HB during the bioconversion process.
Assuntos
Burkholderia , Técnicas Eletroquímicas , Eletrodos , Grafite , Hidroxibutiratos , Polímeros Molecularmente Impressos , Poliésteres , Grafite/química , Poliésteres/química , Hidroxibutiratos/química , Burkholderia/química , Burkholderia/metabolismo , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Polímeros Molecularmente Impressos/química , Limite de Detecção , Oxirredução , Poli-HidroxibutiratosRESUMO
Food additives are chemical compounds intentionally added during foodstuff production to control technological functions, such as pH, viscosity, stability (color, flavor, taste, and odor), homogeneity, and loss of nutritional value. These compounds are fundamental in inhibition the degradation process and prolonging the shelf life of foodstuffs. However, their inadequate employment or overconsumption can adversely affect consumers' health with the development of allergies, hematological, autoimmune, and reproductive disorders, as well as the development of some types of cancer. Thus, the development and application of simple, fast, low-cost, sensitivity, and selectivity analytical methods for identifying and quantifying food additives from various chemical classes and in different foodstuffs are fundamental to quality control and ensuring food safety. This review presents trends in the detection of food additives in foodstuffs using differential pulse voltammetry and square wave voltammetry, the main pulse voltammetric techniques, indicating the advantages, drawbacks, and applicability in food analysis. Are discussed the importance of adequate choices of working electrode materials in the improvements of analytical results, allowing reliable, accurate, and inexpensive voltammetric methods for detecting these compounds in foodstuffs samples.
Assuntos
Técnicas Eletroquímicas , Aditivos Alimentares , Análise de Alimentos , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Aditivos Alimentares/análise , Análise de Alimentos/métodosRESUMO
A fully reusable electrochemical device is proposed for the first time made from laser cutting and a homemade conductive ink composed of carbon and nail polish. As a sensor substrate, we applied polymethyl methacrylate, which allows the surface to be renewed by simply removing and reapplying a new layer of ink. In addition to the ease of renewing the sensor's conductive surface, the design of the device has allowed for the integration of different forms of analysis. The determination of L-Dopa was performed using DPV, which presented a linear response range between 5.0 and 1000.0 µmol L-1, and a LOD of 0.11 µmol L-1. For dopamine, a flow injection analysis system was employed, and using the amperometric technique measurements were performed with a linear ranging from 2.0 to 100.0 µmol L-1 and a LOD of 0.26 µmol L-1. To demonstrate its applicability, the device was used in the quantification of analytes in pharmaceutical drug and synthetic urine samples.
Assuntos
Grafite , Levodopa , Levodopa/análise , Dopamina/análise , Técnicas Eletroquímicas/métodos , Eletrodos , Reprodutibilidade dos TestesRESUMO
Alzheimer's disease (AD) is considered one of the main progressive chronic diseases in elderly individuals. Early diagnosis using related biomarkers, specifically beta-amyloid peptide (Aß), allows finding expected treatment routes. Here, we developed an electrochemical aptasensing platform for AD by employing a glassy carbon electrode (GCE) modified with a layer of jagged gold (JG) nanostructure (diameter: 60-185 nm) and graphene oxide-carboxylic acid functionalized multiwalled carbon nanotubes (GO-c-MWCNTs) nanocomposite. These surface modifications acted as the signal amplifier and provided an optimum nano-interface substrate for immobilizing aptamer strands. The measurements of Aß were performed via differential pulse voltammetry (DPV), and the aptasensor detected the analyte in a linear range from 0.1 pg mL-1 to 1 ng mL-1, with an estimated limit of detection (LOD) of about 0.088 pg mL-1 (S/N = 3). The aptasensor showed sufficient stability (11 days), reversibility (three times), and reproducibility (five times re-fabrication with relative standard deviation (RSD): 1.27). The potential interfering agents showed negligible impact on the sensing performance. Finally, the application of the aptasensor was evaluated in the presence of 10 serum samples, and the recovery values were from 93 to 110.1%.
Assuntos
Doença de Alzheimer , Nanocompostos , Nanotubos de Carbono , Idoso , Humanos , Doença de Alzheimer/diagnóstico , Reprodutibilidade dos Testes , OuroRESUMO
Seafood consumption is the primary exposure route for trace metals like mercury. Accordingly, canned tuna meat has been focused on by researchers because of the potential bioaccumulation of high amounts of mercury. This study aimed to test a novel and reliable electroanalytical method employing a working electrode consisting of gold-nanoparticle-modified carbon microfibers to quantify total mercury in canned tuna samples. Determination was achieved via differential pulse anodic stripping voltammetry. The proposed method had a limit of detection of 3.9781 ± 0.0001 µg L-1 and a limit of quantification of 33.6634 ± 0.0001 µg L-1, with a sensitivity of 0.3275 nA µg L-1. The modified electrode was evaluated in samples taken from three canned tuna brands sold in the Sangolquí parish in Rumiñahui, Ecuador. These brands, coded A, B, and C, represent 47.92%, 27.08%, and 11.98% of all canned tuna sold in the Ecuadorian market, respectively. The resulting respective total mercury concentrations were 0.5999 ± 0.0001 mg kg-1; 0.9387 ± 0.0001 mg kg-1; and 0.3442 ± 0.0001 mg kg-1 for A, B, and C. Method accuracy was determined through the recovery percentages of ≥98%, which indicated acceptable accuracy for the final optimized method. Mean mercury concentrations for all samples did not represent a carcinogenic risk for consumers. However, the values obtained for potential no-carcinogenic risk and daily consumption rate suggest that consumers of tuna canned in water, particularly brand C, may be at risk.
Assuntos
Mercúrio , Nanopartículas , Animais , Mercúrio/análise , Atum , Ouro , Equador , Microeletrodos , Fibra de Carbono , Alimentos Marinhos/análise , Carcinógenos , Contaminação de Alimentos/análiseRESUMO
A new electrochemical device fabricated by the combination of 3D printing manufacturing and laser-generated graphene sensors is presented. Cell and electrodes were 3D printed by the fused deposition modeling (FDM) technique employing acrylonitrile butadiene styrene filament (insulating material that composes the cell) and conductive filament (lab-made filament based on graphite dispersed into polylactic acid matrix) to obtain reference and auxiliary electrodes. Infrared-laser engraved graphene, also reported as laser-induced graphene (LIG), was produced by laser conversion of a polyimide substrate, which was assembled in the 3D-printed electrochemical cell that enables the analysis of low volumes (50-2000 µL). XPS analysis revealed the formation of nitrogen-doped graphene multilayers that resulted in excellent electrochemical sensing properties toward the detection of atropine (ATR), a substance that was found in beverages to facilitate sexual assault and other criminal acts. Linear range between 5 and 35 µmol L-1, detection limit of 1 µmol L-1, and adequate precision (RSD = 4.7%, n = 10) were achieved using differential-pulse voltammetry. The method was successfully applied to beverage samples with recovery values ranging from 80 to 105%. Interference studies in the presence of species commonly found in beverages confirmed satisfactory selectivity for ATR sensing. The devices proposed are useful portable analytical tools for on-site applications in the forensic scenario.
RESUMO
A magnetic graphite-epoxy composite (m-GEC) electrochemical sensor is presented based on magnetic imprinted polymer (mag-MIP) to determine homocysteine (Hcy). Mag-MIP was synthesized via precipitation polymerization, using functionalized magnetic nanoparticles (Fe3O4) together with the template molecule (Hcy), the functional monomer 2-hydroxyethyl methacrylate (HEMA), and the structural monomer trimethylolpropane trimethacrylate (TRIM). For mag-NIP (magnetic non-imprinted polymer), the procedure was the same in the absence of Hcy. Morphological and structural properties of the resultant mag-MIP and mag-NIP were examined using TEM, FT-IR, and Vibrating Sample Magnetometer. Under optimized conditions, the m-GEC/mag-MIP sensor showed a linear range of 0.1-2 µmol L-1, with a limit of detection (LOD) of 0.030 µmol L-1. In addition, the proposed sensor responded selectively to Hcy compared to several interferents present in biological samples. The recovery values determined by differential pulse voltammetry (DPV) were close to 100% for natural and synthetic samples, indicating good method accuracy. The developed electrochemical sensor proves to be a suitable device for determining Hcy, with advantages related to magnetic separation and electrochemical analysis.
Assuntos
Grafite , Nanopartículas de Magnetita , Impressão Molecular , Polímeros Molecularmente Impressos , Espectroscopia de Infravermelho com Transformada de Fourier , Polímeros/química , Grafite/química , Impressão Molecular/métodosRESUMO
This study evaluated the antioxidant properties and chemical composition of the seeds, pulp and peels of Ungurahua (Oenocarpus bataua) and Pasu (Gustavia macarenensis)-fruits, native to the Ecuadorian Amazon. The antioxidant capacity was measured by 1,1-diphenyl-2-picrylhydrazyl (DPPH) and cyclic voltammetry (antioxidant index 50 (AI50)) assays; differential pulse voltammetry was used to evaluate antioxidant power using the electrochemical index. The total phenolic content, as well as the yellow flavonoid and anthocyanin content, were quantified via spectrophotometry. In addition, the trans-resveratrol and ascorbic acid content were evaluated through high performance liquid chromatography (HPLC). Ultra-performance liquid chromatography-mass spectrometry (UPLC-MS) was used to identify secondary metabolites with possible therapeutic properties. Results showed that the Pasu peel and seed extracts had the highest antioxidant capacity, followed by the Ungurahua peel; these results were consistent for both spectroscopic and electrochemical assays. HPLC and UPLC-MS analysis suggest that Oenocarpus bataua and Gustavia macarenensis are important sources of beneficial bioactive compounds.
RESUMO
A laser-scribed graphene (LSG) device fabricated on polymeric polyetherimide (PEI) substrate is reported for sensitive electrochemical detection of xylazine (XLZ), a veterinary drug that has been associated with drug-facilitated crimes. Morphological characterization was made by scanning electron microscopy (SEM), demonstrating that the electrochemical device presents a highly porous carbonaceous structure. In addition, Raman spectroscopy, Fourier-transform infrared spectroscopy (FTIR), wettability, electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV) measurements were used to characterize the PEI-LSG material, which showed superior electroanalytical performance after a simple anodic treatment in an alkaline medium (applying 2 V for 120 s in 0.1 mol L-1 NaOH solution). The electrochemical determination of XLZ was carried out using square wave voltammetry (SWV), which showed sensitivity and coefficient of determination (R2) equal to 0.206 ± 0.008 A L mol-1 cm-2 and 0.991, respectively. In addition, we obtained a low limit of detection (LOD) of 1.39 × 10-7 mol L-1 with a linear response in the concentration range 5.0 to 200.0 × 10-6 mol L-1. The PEI-LSG electrochemical sensor was applied to XLZ detection in commercial beverage and synthetic urine samples, providing recoveries between 96.0 and 114.8%. Collectively, our electrochemical sensor presents an easy method to manufacture reproducible (relative standard deviation (RSD) of 2.56%), low-cost ($0.12), and single-use (disposable) devices, which is a promising way for in-field determination of drug-facilitated sexual assaults and other relevant applications.
Assuntos
Grafite , Grafite/química , Xilazina , Técnicas Eletroquímicas/métodos , Lasers , BebidasRESUMO
The development of a homemade carbon black composite filament with polylactic acid (CB-PLA) is reported. Optimized filaments containing 28.5% wt. of carbon black were obtained and employed in the 3D printing of improved electrochemical sensors by fused deposition modeling (FDM) technique. The fabricated filaments were used to construct a simple electrochemical system, which was explored for detecting catechol and hydroquinone in water samples and detecting hydrogen peroxide in milk. The determination of catechol and hydroquinone was successfully performed by differential pulse voltammetry, presenting LOD values of 0.02 and 0.22 µmol L-1, respectively, and recovery values ranging from 91.1 to 112% in tap water. Furthermore, the modification of CB-PLA electrodes with Prussian blue allowed the non-enzymatic amperometric detection of hydrogen peroxide at 0.0 V (vs. carbon black reference electrode) in milk samples, with a linear range between 5.0 and 350.0 mol L-1 and low limit of detection (1.03 µmol L-1). Thus, CB-PLA can be successfully applied as additively manufactured electrochemical sensors, and the easy filament manufacturing process allows for its exploration in a diversity of applications.
Assuntos
Hidroquinonas , Fuligem , Catecóis/análise , Peróxido de Hidrogênio , Hidroquinonas/análise , Poliésteres , ÁguaRESUMO
An electrochemical device using copper-based metalorganic franmeworks (MOF) associated with reduced graphene oxide to improve the charge transfer, stability, and adherence of the structures on the surface of the electrodes was developed. The syntheses of these materials were confirmed using scanning electron microscopy, thermogravimetric analysis, X-ray diffraction, Fourier transform infrared and Raman spectroscopy. For the first time, this type of sensor was applied to a systematic study to understand the action mechanism of MOFs and reduced graphene oxide in the electrochemical detection of paraquat pesticide. Under optimized conditions, paraquat was detected in standard solutions by differential pulse voltammetry (- 0.8 to - 0.3 V vs Ag/AgCl), achieving a linear response range between 0.30 and 5.00 µmol L-1. The limits of detection and quantification were 50.0 nmol L-1 and 150.0 nmol L-1, respectively. We assessed the accuracy of the proposed device to determine paraquat in water and human blood serum samples by recovery study, obtaining recovery values ranging from 98 to 104%. Furthermore, the selectivity of the proposed electrode for paraquat detection was evaluated against various interferences, demonstrating their promising application in environmental analysis.
Assuntos
Estruturas Metalorgânicas , Cobre/química , Técnicas Eletroquímicas/métodos , Eletrodos , Grafite , Humanos , Limite de Detecção , Estruturas Metalorgânicas/química , ParaquatRESUMO
The synthesis and characterization of a novel titania/silica hybrid xerogel subsequently modified with 4-methylpyridine (4-Pic), named TiSi4Pic+Cl- is reported. The physicochemical, structural and thermal properties of TiSi4Pic+Cl- were characterized using several techniques. Anchoring cobalt(II) phthalocyanine (CoTsPc) in TiSi4Pic+Cl- showed greater electroanalytical sensitivity over other sensors built with these materials. A novel electroanalytical method was developed to quantify the noxious biocide pentachlorophenol (PCP) for environmental monitoring. The peak current intensity increased linearly with the analyte concentration in the range between 0.99 and 4.21 µmol L-1, based on the oxidation process (at + 0.81 V, vs. Ag/AgCl) of differential pulse voltammetry (DPV). The estimated limit of detection (LOD) was 29 nmol L-1. Recovery tests in environmental samples showed a PCP concentration of 2.05 ± 0.03 µmol L-1 (n = 3). The method was statistically validated by comparing the PCP concentrations with those obtained by molecular absorption spectrometry and high-performance liquid chromatography-diode array detection (HPLC-DAD). At a 95% confidence level, no difference between the results was found, therefore confirming the excellent accuracy of the proposed method.
Assuntos
Pentaclorofenol , Cobalto/química , Eletrodos , Indóis , Isoindóis , Dióxido de Silício , TitânioRESUMO
This study aimed to investigate the antioxidant activity of extracts obtained from jabuticaba (Myrciaria cauliflora) seeds. Ethanolic (ETJS), methanolic (MEJS), aqueous (AQJS), and propanone (PRJS) extracts was assessed by measuring spectrophotometrically their ability to scavenge DPPH· , ABTS·+ , HOCl, and O2 ·- radicals. Electrochemical methods were employed, and the obtained data presented a good correlation with the radical scavenging results. The extracts were also able to attenuate lipid peroxidation induced by Fe2+ ions in phospholipids due to their chelation ability. The extracts protected human erythrocytes against oxidative cellular damage caused by AAPH, which was confirmed by using FESEM analysis. PRJS extract demonstrated the highest effect in all assays used in this work. Our findings prove that jabuticaba seeds are an important source of antioxidants which act by different mechanisms. This study opens new frontiers regarding the use of this fruit byproduct as a food additive. PRACTICAL APPLICATIONS: Jabuticaba seeds are usually discarded as waste by food industries, but they are rich in bioactive products and present interesting biological properties. Herein, we demonstrated that their extracts show remarkable antioxidant power against different reactive oxygen species, which are involved in several human pathologies. In this way, this by-product can be further used in the development of products to protect the human body against diseases related to oxidative stress.
Assuntos
Antioxidantes , Myrtaceae , Antioxidantes/química , Eritrócitos , Humanos , Myrtaceae/química , Estresse Oxidativo , Extratos Vegetais/química , Sementes/químicaRESUMO
A label-free nanoimmunosensor is reported based on p53/CeO2/PEDOT nanobiocomposite-decorated screen-printed gold electrodes (SPAuE) for the electrochemical detection of anti-p53 autoantibodies. CeO2 nanoparticles (NPs) were synthesized and stabilized with cyanopropyltriethoxysilane by a soft chemistry method. The nanoimmunosensing architecture was prepared by in situ electropolymerization of 3,4-ethylenedioxythiophene (EDOT) on SPAuE in the presence of CeO2 NPs. The CeO2 NPs and Ce/PEDOT/SPAuE were characterized by scanning and transmission electron microscopy, dynamic and electrophoretic light scattering, ultraviolet-visible spectrophotometry, X-ray diffraction, Fourier-transform infrared spectroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. Ce/PEDOT/SPAuE was biofunctionalized with p53 antigen by covalent bonding for the label-free determination of anti-p53 autoantibodies by differential pulse voltammetry. The nanobiocomposite-based nanoimmunosensor detected anti-p53 autoantibodies in a linear range from 10 to 1000 pg mL-1, with a limit of detection (LOD) of 3.2 pg mL-1. The nanoimmunosensor offered high specificity, selectivity, and long-term storage stability with great potential to detect anti-p53 autoantibodies in serum samples. Overall, incorporating organo-functional nanoparticles into polymeric matrices can provide a simple-to-assemble, rapid, and ultrasensitive approach for on-site screening of anti-p53 autoantibodies and other disease-related biomarkers with low sample volumes.
Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Nanocompostos , Autoanticorpos , Técnicas Biossensoriais/métodos , Compostos Bicíclicos Heterocíclicos com Pontes , Cério , Nanopartículas Metálicas/química , Nanocompostos/química , PolímerosRESUMO
Low oxidation stability is the main drawback of biodiesels and biokerosenes that is overcome by using antioxidants, which can be combined due to synergistic effects. This paper demonstrates that 3D-printed electrochemical devices can be applied to biofuel electroanalysis, including the monitoring of oxidation stability by quantifying the antioxidant content in biofuels. Fabrication requires 3D-printed acrylic templates at which a polylactic acid (PLA) filament with conducting carbon-black filling sensors is extruded by a 3D pen. The antioxidants butyl hydroxyanisole (BHA) and tert-butylhydroquinone (TBHQ) are the most employed additives in biodiesel production, and thus, their electrochemical behavior was investigated; 2,6-ditertbutylphenol (2,6-DTBP) was included in this investigation because it is commonly added to biokerosenes. The electrochemical surface treatment of the 3D-printed electrodes improved the current responses of all antioxidants; however, the electrochemical oxidation of TBHQ was clearly more affected by an electrocatalytic action shifting its oxidation towards less positive potentials (~200 mV), which resulted in a better separation of TBHQ and BHA oxidation peaks (+0.4 and +0.6 V vs Ag|AgCl, respectively). The oxidation of 2,6-DTBP occurred at more positive potentials (+1.2 V vs Ag|AgCl). The simultaneous determination of TBHQ and BHA by differential-pulse voltammetry resulted in linear responses in the range 0.5 and 175 µmol L-1 with limits of detection and quantification of 0.15 µmol L-1 and 0.5 µmol L-1, respectively. The presence of Fe3+, Cu2+, Pb2+, Mn2+, Cd2+, and Zn2+, even in high concentrations, did not interfere in the determination of TBHQ and BHA. The determination of 2,6-DTBP in biokerosene was achieved by cyclic voltammetry. All relative standard deviations (RSD) were lower than 6.0 %, indicating adequate precision of the methods. Spiked biofuel samples were analyzed (after dilution in electrolyte) and recovery values between 85 and 120% were obtained, which indicates absence of sample matrix effects.
Assuntos
Antioxidantes/química , Biocombustíveis/análise , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Poliésteres/química , Estrutura Molecular , Impressão Tridimensional , FuligemRESUMO
This work presents the simultaneous quantification of four non-steroidal anti-inflammatory drugs (NSAIDs), paracetamol, diclofenac, naproxen, and aspirin, in mixture solutions, by a laboratory-made working electrode based on carbon paste modified with multi-wall carbon nanotubes (MWCNT-CPE) and Differential Pulse Voltammetry (DPV). Preliminary electrochemical analysis was performed using cyclic voltammetry, and the sensor morphology was studied by scanning electronic microscopy and electrochemical impedance spectroscopy. The sample set ranging from 0.5 to 80 µmol L-1 was prepared using a complete factorial design (34) and considering some interferent species such as ascorbic acid, glucose, and sodium dodecyl sulfate to build the response model and an external randomly subset of samples within the experimental domain. A data compression strategy based on discrete wavelet transform was applied to handle voltammograms' complexity and high dimensionality. Afterward, Partial Least Square Regression (PLS) and Artificial Neural Networks (ANN) predicted the drug concentrations in the mixtures. PLS-adjusted models (n = 12) successfully predicted the concentration of paracetamol and diclofenac, achieving correlation values of R ≥ 0.9 (testing set). Meanwhile, the ANN model (four layers) obtained good prediction results, exhibiting R ≥ 0.968 for the four analyzed drugs (testing stage). Thus, an MWCNT-CPE electrode can be successfully used as a potential sensor for voltammetric determination and NSAID analysis.
Assuntos
Acetaminofen , Nanotubos de Carbono , Técnicas Eletroquímicas/métodos , Diclofenaco , Nanotubos de Carbono/química , Quimiometria , Eletrodos , Anti-Inflamatórios não EsteroidesRESUMO
A new protocol for the analysis of the azo-dye carmoisine (CMS) is presented by coupling differential pulse voltammetry (DPV) with a cathodically pretreated boron-doped diamond electrode (CPT-BDDE), in phosphate buffer solution (pH 2.0). The CMS presented diffusion-controlled oxidation and reduction peaks at +0.88 and -0.15 V vs Ag/AgCl, respectively. The effect of the pretreatment conditions, pH, and supporting electrolytes were evaluated to the voltammetric determination of CMS. Under optimized conditions, the differential pulse voltammetric signals for CMS were linear over the concentration range of 0.059-1.31 µmol L-1 and 0.010-0.079 µmol L-1 with limits of detection of 7.0 and 3.0 nmol L-1, for the anodic and cathodic processes respectively. The method was precise for CMS determination (RSD < 5.0%) and selective against other dyes. The developed protocol was successfully applied in the analysis of CMS in surface water and foodstuffs with accurate results in comparison with those obtained using a validated spectrophotometric method.
Assuntos
Boro , Diamante , Compostos Azo , Eletrodos , NaftalenossulfonatosRESUMO
Disposable screen-printed electrodes based on the use of graphite-polyurethane composites modified with magnetite nanoparticles (MNP-SPE) or chitosan-coated magnetite nanoparticles (CHMNP-SPE) are described. The MNP and CHMNP were synthetized and comparatively characterized by TEM, XRD, FTIR, and TGA/DTG. The MNP-SPE and CHMNP-SPE were characterized by SEM and EDX. After optimization of the MNP percentage in MNP-SPE, the materials were electrochemically characterized by cyclic voltammetry, EIS, and chronocoulometry. The electrodes were tested for their performance towards sensing of epinephrine (EP). The CHMNP-SPE is found to have better electrochemical responses in comparison to the MNP-SPE. This is assumed to be due to the chitosan coating which also protects the MNPs from oxidation under air and at different applied potential fields. The performances of the MNP-SPE and CHMNP-SPE were studied by DPV after optimization of equilibration time and DPV parameters. Response is linear in the 0.1-0.8 µM EP concentration range, at 0.03 V (vs. pseudo-Ag/AgCl), and the detection limit is 25 nM for the MNP-SPE. The linear response for the CHMNP-SPE was 0.1-0.6 µM, at 0.0 V (vs. pseudo-Ag/AgCl), and a LOD of 14 nM was achieved. The devices were used for the quantification of EP in synthetic urine and in cerebrospinal synthetic fluids. Recoveries from spiked samples are in the 95.6-102.2% range for the CHMNP-SPE and in the 98.3-109% range for MNP-SPE. The stability of the respective sensors was investigated and compared over a period of 5 months. The EP peak currents were found to decrease by only 4% for the CHMNP-SPE, while the MNP-SPE lost 23% of its EP peak current. Accordingly, the CHMNP-SPE was chosen as the most stable and sensitive sensor for EP. Graphical abstract Schematic figure of modification of a graphite-polyurethane screen-printed composite electrode with magnetite nanoparticles (MNPs) and chitosan-coated magnetite nanoparticles (CHMNPs) for the voltammetric determination of epinephrine (EP). Improved response of CHMNP-SPE (black voltammogram) in comparison to MNP-SPE (red voltammogram) was attributed to the protection of MNP from oxidation.
Assuntos
Quitosana/química , Técnicas Eletroquímicas/métodos , Epinefrina/urina , Grafite/química , Nanopartículas de Magnetita/química , Poliuretanos/química , Técnicas Eletroquímicas/instrumentação , Eletrodos , Epinefrina/química , Limite de Detecção , OxirreduçãoRESUMO
An original voltammetric screening method, employing glassy carbon electrode (GCE) with the differential-pulse voltammetry technique (DPV), has been developed to determine residues of the anti-parasitic agent Ronidazole (RNZ) in bovine meat. By using cyclic voltammetry (CV), it has been demonstrated that an irreversible cathodic process occurs at approximately -0.740 V (vs. Ag|AgCl, KCl 3 mol L-1) in a 0.100 mol L-1 phosphate buffer at pH 6.5 as supporting electrolyte. Furthermore, the behavior of RNZ in CV indicates the occurrence of a diffusion mass transfer process to the working electrode surface. The RNZ reduction mechanism was proposed as a 6-electron transfer, similar to Metronidazole under the same pH range. Quantification of RNZ and method validation were then carried out by DPV. The relative standard deviation (RSD) were 3.21% for intraday precision of 10 consecutive repetitions and 6.78% for interday precision after five analysis. Limits of detection and quantification were also obtained, and the values were 0.107 and 0.358 mg kg-1, respectively. The recovery percentage for three different concentrations of RNZ in the bovine meat matrix ranged between 98.1% and 100.3%. The method proved to be efficient for screening RNZ in bovine meat.
Assuntos
Eletroquímica/métodos , Análise de Alimentos/métodos , Carne Vermelha/análise , Ronidazole/análise , Animais , Carbono , Bovinos , Eletroquímica/instrumentação , Eletrodos , Análise de Alimentos/instrumentação , Contaminação de Alimentos/análise , Limite de Detecção , Reprodutibilidade dos TestesRESUMO
Two analytical methods were developed using electrochemical and spectrometric techniques for the simultaneous determination of endocrine disruptors triclosan and methylparaben in the monitoring of personal care products. For the electroanalytical analyses, a sensitive electrode based on graphene quantum dots supported in chitosan was employed. Under optimized conditions and a working potential of typically + 0.60 V for triclosan and + 0.81 V (vs. Ag/AgCl) for methylparaben, the calibration plots obtained by differential pulse voltammetry were linear in the range 0.10 to 10.0 µmol L-1. The detection limits were 0.03 and 0.04 µmol L-1 for triclosan and methylparaben, respectively. For the spectrometric method, UV/VIS spectrometry was used with a mathematical processing of non-linear deconvolution. This processing was used to solve the problem of overlapping absorption bands of triclosan (282 nm) and methylparaben (257 nm), which enabled simultaneous determination. The calibration plots by UV/VIS spectrometry were linear in the range 1.0 to 14.0 µmol L-1 with detection limits of 0.42 and 0.37 µmol L-1, respectively, for triclosan and methylparaben. Similar results obtained from the calibration plots of individual analytes suggest that the methods can be applied for individual or simultaneous determination of these species. Both methods were employed in the analysis of five samples of personal care products: toothpaste, antiseptic soap, antiseptic deodorant, shampoo, and a bath kit (soap and shampoo). The statistical tests indicated that there were no significant differences regarding the accuracy and precision of the data provided by the two methods described herein. Graphical abstract Schematic representation for simultaneous determination of triclosan and methylparaben: electrochemical method employing an electrode modified with graphene quantum dots supported in chitosan and spectrometric method applying a non-linear deconvolution of spectrum.