Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.327
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38868706

RESUMO

Background and Aim: Endoscopic ultrasound shear wave elastography (EUS-SWE) can facilitate an objective evaluation of pancreatic fibrosis. Although it is primarily applied in evaluating chronic pancreatitis, its efficacy in assessing early chronic pancreatitis (ECP) remains underinvestigated. This study evaluated the diagnostic accuracy of EUS-SWE for assessing ECP diagnosed using the Japanese diagnostic criteria 2019. Methods: In total, 657 patients underwent EUS-SWE. Propensity score matching was used, and the participants were classified into the ECP and normal groups. ECP was diagnosed using the Japanese diagnostic criteria 2019. Pancreatic stiffness was assessed based on velocity (Vs) on EUS-SWE, and the optimal Vs cutoff value for ECP diagnosis was determined. A practical shear wave Vs value of ≥50% was considered significant. Results: Each group included 22 patients. The ECP group had higher pancreatic stiffness than the normal group (2.31 ± 0.67 m/s vs. 1.59 ± 0.40 m/s, p < 0.001). The Vs cutoff value for the diagnostic accuracy of ECP, as determined using the receiver operating characteristic curve, was 2.24m/s, with an area under the curve of 0.82 (95% confidence interval: 0.69-0.94). A high Vs was strongly correlated with the number of EUS findings (rs = 0.626, p < 0.001). Multiple regression analysis revealed that a history of acute pancreatitis and ≥2 EUS findings were independent predictors of a high Vs. Conclusions: There is a strong correlation between EUS-SWE findings and the Japanese diagnostic criteria 2019 for ECP. Hence, EUS-SWE can be an objective and invaluable diagnostic tool for ECP diagnosis.

2.
J Biomed Opt ; 29(7): 076003, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38989529

RESUMO

Significance: Tissues' biomechanical properties, such as elasticity, are related to tissue health. Optical coherence elastography produces images of tissues based on their elasticity, but its performance is constrained by the laser power used, working distance, and excitation methods. Aim: We develop a new method to reconstruct the elasticity contrast image over a long working distance, with only low-intensity illumination, and by non-contact acoustic wave excitation. Approach: We combine single-photon vibrometry and quantum parametric mode sorting (QPMS) to measure the oscillating backscattered signals at a single-photon level and derive the phantoms' relative elasticity. Results: We test our system on tissue-mimicking phantoms consisting of contrast sections with different concentrations and thus stiffness. Our results show that as the driving acoustic frequency is swept, the phantoms' vibrational responses are mapped onto the photon-counting histograms from which their mechanical properties-including elasticity-can be derived. Through lateral and longitudinal laser scanning at a fixed frequency, a contrast image based on samples' elasticity can be reliably reconstructed upon photon level signals. Conclusions: We demonstrated the reliability of QPMS-based elasticity contrast imaging of agar phantoms in a long working distance, low-intensity environment. This technique has the potential for in-depth images of real biological tissue and provides a new approach to elastography research and applications.


Assuntos
Técnicas de Imagem por Elasticidade , Imagens de Fantasmas , Fótons , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Elasticidade , Reprodutibilidade dos Testes
3.
Artigo em Inglês | MEDLINE | ID: mdl-38969073

RESUMO

BACKGROUND & AIMS: Vibration-controlled transient elastography (VCTE) is used in clinical practice to risk stratify liver transplant (LT) recipients, however, there is currently little data demonstrating the relationship between VCTE and clinical outcomes. METHODS: 362 adult LT recipients with successful VCTE examination between 2015 and 2022 were included. Presence of advanced fibrosis was defined as liver stiffness measurement (LSM) ≥10.5kPa and hepatic steatosis as controlled attenuation parameter (CAP)≥ 270 dB/m. The outcomes of interest included all-cause mortality, myocardial infarction (MI), and graft cirrhosis using cumulative incidence analysis that accounted for the competing risks of these outcomes. RESULTS: The LSM was elevated in 64 (18%) and CAP in 163 (45%) of LT recipients. The baseline LSM values were similar in patients with elevated vs. normal CAP values. After a median follow up of 65 (IQR 20, 140) months from LT to baseline VCTE, 66 (18%) of patients died, 12 (3%) developed graft cirrhosis, and 18 (5%) experienced an MI. Baseline high LSM was independently associated with all-cause mortality (HR 1.97, 95% CI 1.11, 3.50, p=0.02) and new onset cirrhosis (HR 6.74, 95% CI 2.08, 21.79, p<0.01). A higher CAP value was significantly and independently associated with increased risk of experiencing a MI over study follow up with HR 4.14 [95% CI 1.29, 13.27, p=0.017]. CONCLUSIONS: The VCTE based parameters are associated with clinical outcomes and offer the potential to be incorporated into clinical risk stratification strategies to improve outcomes among LT recipients.

4.
Ultrasound Med Biol ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38969525

RESUMO

OBJECTIVE: To develop and validate a predictive model for sarcopenia. METHODS: A total of 240 subjects who visited our hospital between August 2021 and May 2023 were randomly divided by time of entry into a training set containing 2/3 of patients and a validation set containing 1/3 of patients. The muscle thickness (MT), echo intensity (EI), and shear wave velocity (SWV) of the medial gastrocnemius muscle were measured. Indicators that were meaningful in the univariate analysis in the training set were included in a binary logistic regression to derive a regression model, and the model was evaluated using a consistency index, calibration plot, and clinical validity curve. Diagnostic efficacy and clinical applicability were compared between the model and unifactorial indicators. RESULTS: Four meaningful variables, age, body mass index (BMI), MT, and SWV, were screened into the predictive model. The model was Logit Y = 21.292 + 0.065 × Age - 0.411 × BMI - 0.524 × MT - 3.072 × SWV. The model was well differentiated with an internally validated C-index of 0.924 and an external validation C-index of 0.914. The calibration plot predicted probabilities against actual probabilities showed excellent agreement. The specificity, sensitivity, and Youden's index of the model were 73.80%, 97.40%, and 71.20%, respectively, when using the diagnostic cut-off value of >0.279 for sarcopenia. The logistic model had higher diagnostic efficacy (p < 0.001) and higher net clinical benefit (p < 0.001) over the same threshold range compared to indicators. CONCLUSION: The logistic model of sarcopenia has been justified to have good discriminatory, calibrated, and clinical validity, and has higher diagnostic value than indicators.

5.
J Orthop Surg Res ; 19(1): 389, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956611

RESUMO

BACKGROUND: Elevation of carpal tunnel pressure is known to be associated with carpal tunnel syndrome. This study aimed to correlate the shear wave elastography in the transverse carpal ligament (TCL) with carpal tunnel pressures using a cadaveric model. METHODS: Eight human cadaveric hands were dissected to evacuate the tunnels. A medical balloon was inserted into each tunnel and connected to a pressure regulator to simulate tunnel pressure in the range of 0-210 mmHg with an increment of 30 mmHg. Shear wave velocity and modulus was measure in the middle of TCL. RESULTS: SWV and SWE were significantly dependent on the pressure levels (p < 0.001), and positively correlated to the tunnel pressure (SWV: R = 0.997, p < 0.001; SWE: R = 0.996, p < 0.001). Regression analyses showed linear relationship SWV and pressure (SWV = 4.359 + 0.0263 * Pressure, R2 = 0.994) and between SWE and pressure (SWE = 48.927 + 1.248 * Pressure, R2 = 0.996). CONCLUSION: The study indicated that SWV and SWE in the TCL increased linearly as the tunnel pressure increased within the current pressure range. The findings suggested that SWV/SWE in the TCL has the potential for prediction of tunnel pressure and diagnosis of carpal tunnel syndrome.


Assuntos
Cadáver , Síndrome do Túnel Carpal , Técnicas de Imagem por Elasticidade , Ligamentos Articulares , Pressão , Humanos , Síndrome do Túnel Carpal/diagnóstico por imagem , Síndrome do Túnel Carpal/fisiopatologia , Técnicas de Imagem por Elasticidade/métodos , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso
6.
Clin Exp Ophthalmol ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38964827

RESUMO

BACKGROUND: A high-frequency point-of-care (POC) ultrasound instrument was used to evaluate the microstructural and biomechanical properties of the anterior sclera in vivo using parameters computed from quantitative ultrasound (QUS) methods. METHODS: In this cross-sectional study, both eyes of 85 enrolled patients were scanned with the POC instrument and ultrasound data were processed to obtain QUS parameters. Pearson correlation and multi-linear regression were used to identify relationships between QUS parameters and refractive error (RE) or axial length. After categorising eyes based on RE, binary support vector machine (SVM) classifiers were trained using the QUS or ophthalmic parameters (anterior chamber depth, central corneal thickness, corneal power, and intraocular pressure) to classify each eye. Classifier performance was evaluated by computing the area under the receiver-operating characteristic curve (AUC). RESULTS: Individual QUS parameters correlated with RE and axial length (p < 0.05). Multi-linear regression revealed significant correlation between the set of QUS parameters and both RE (R = 0.49, p < 0.001) and axial length (R = 0.46, p = 0.001). Classifiers trained with QUS parameters achieved higher AUC (𝑝 = 0.06) for identifying myopic eyes (AUC = 0.71) compared to classifiers trained with ophthalmic parameters (AUC = 0.63). QUS-based classifiers attained the highest AUC when identifying highly myopic eyes (AUC = 0.77). CONCLUSIONS: QUS parameters correlate with progressing myopia and may be indicative of myopia-induced microstructural and biomechanical changes in the anterior sclera. These methods may provide critical clinical information complementary to standard ophthalmic measurements for predicting myopia progression and risk assessment for posterior staphyloma formation.

7.
Acta Biomater ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38960112

RESUMO

Three-dimensional variation in structural components or fiber alignments results in complex mechanical property distribution in tissues and biomaterials. In this paper, we use a physics-informed UNet-based neural network model (El-UNet) to discover the three-dimensional (3D) internal composition and space-dependent material properties of heterogeneous isotropic and transversely isotropic materials without a priori knowledge of the composition. We then show the capabilities of El-UNet by validating against data obtained from finite-element simulations of two soft tissues, namely, brain tissue and articular cartilage, under various loading conditions. We first simulated compressive loading of 3D brain tissue comprising of distinct white matter and gray matter mechanical properties undergoing small strains with isotropic linear elastic behavior, where El-UNet reached mean absolute relative errors under 1.5% for elastic modulus and Poisson's ratio estimations across the 3D volume. We showed that the 3D solution achieved by El-UNet was superior to relative stiffness mapping by inverse of axial strain and two-dimensional plane stress/plane strain approximations. Additionally, we simulated a transversely isotropic articular cartilage with known fiber orientations undergoing compressive loading, and accurately estimated the spatial distribution of all five material parameters, with mean absolute relative errors under 5%. Our work demonstrates the application of the computationally efficient physics-informed El-UNet in 3D elasticity imaging and provides methods for translation to experimental 3D characterization of soft tissues and other materials. The proposed El-UNet offers a powerful tool for both in vitro and ex vivo tissue analysis, with potential extensions to in vivo diagnostics. STATEMENT OF SIGNIFICANCE: Elasticity imaging is a technique that reconstructs mechanical properties of tissue using deformation and force measurements. Given the complexity of this reconstruction, most existing methods have mostly focused on 2D problems. Our work is the first implementation of physics-informed UNets to reconstruct three-dimensional material parameter distributions for isotropic and transversely isotropic linear elastic materials by having deformation and force measurements. We comprehensively validate our model using synthetic data generated using finite element models of biological tissues with high bio-fidelity-the brain and articular cartilage. Our method can be implemented in elasticity imaging scenarios for in vitro and ex vivo mechanical characterization of biomaterials and biological tissues, with potential extensions to in vivo diagnostics.

8.
Xenotransplantation ; 31(4): e12873, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38961605

RESUMO

BACKGROUND: Significant progress has been made in kidney xenotransplantation in the past few years, and this field is accelerating towards clinical translation. Therefore, surveillance of the xenograft with appropriate tools is of great importance. Ultrasonography has been widely used in kidney allotransplantation and served as an economical and non-invasive method to monitor the allograft. However, questions remain whether the ultrasonographic criteria established for human kidney allograft could also be applied in xenotransplantation. METHODS: In the current study, we established a porcine-rhesus life sustaining kidney xenotransplantation model. The xenograft underwent intensive surveillance using gray-scale, colorful Doppler ultrasound as well as 2D shear wave elastography. The kidney growth, blood perfusion, and cortical stiffness were measured twice a day. These parameters were compared with the clinical data including urine output, chemistry, and pathological findings. RESULTS: The observation continued for 16 days after transplantation. Decline of urine output and elevated serum creatinine were observed on POD9 and biopsy proven antibody-mediated rejection was seen on the same day. The xenograft underwent substantial growth, with the long axis length increased by 32% and the volume increased by threefold at the end of observation. The resistive index of the xenograft arteries elevated in response to rejection, together with impaired cortical perfusion, while the peak systolic velocity (PSV) was not compromised. The cortical stiffness also increased along with rejection. CONCLUSION: In summary, the ultrasound findings of kidney xenograft shared similarities with those in allograft but possessed some unique features. A modified criteria needs to be established for further application of ultrasound in kidney xenotransplantation.


Assuntos
Rejeição de Enxerto , Xenoenxertos , Transplante de Rim , Rim , Macaca mulatta , Transplante Heterólogo , Animais , Transplante Heterólogo/métodos , Transplante de Rim/métodos , Suínos , Rim/diagnóstico por imagem , Humanos , Ultrassonografia/métodos
9.
Cancer Imaging ; 24(1): 88, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38971790

RESUMO

BACKGROUND: The aim of the study were as below. (1) To investigate the feasibility of intravoxel incoherent motion (IVIM)-based virtual magnetic resonance elastography (vMRE) to provide quantitative estimates of tissue stiffness in pulmonary neoplasms. (2) To verify the diagnostic performance of shifted apparent diffusion coefficient (sADC) and reconstructed virtual stiffness values in distinguishing neoplasm nature. METHODS: This study enrolled 59 patients (37 males, 22 females) with one pulmonary neoplasm who underwent computed tomography-guided percutaneous transthoracic needle biopsy (PTNB) with pathological diagnosis (26 adenocarcinoma, 10 squamous cell carcinoma, 3 small cell carcinoma, 4 tuberculosis and 16 non-specific benign; mean age, 60.81 ± 9.80 years). IVIM was performed on a 3 T magnetic resonance imaging scanner before biopsy. sADC and virtual shear stiffness maps reflecting lesion stiffness were reconstructed. sADC and virtual stiffness values of neoplasm were extracted, and the diagnostic performance of vMRE in distinguishing benign and malignant and detailed pathological type were explored. RESULTS: Compared to benign neoplasms, malignant ones had a significantly lower sADC and a higher virtual stiffness value (P < 0.001). Subsequent subtype analyses showed that the sADC values of adenocarcinoma and squamous cell carcinoma groups were significantly lower than non-specific benign group (P = 0.013 and 0.001, respectively). Additionally, virtual stiffness values of the adenocarcinoma and squamous cell carcinoma subtypes were significantly higher than non-specific benign group (P = 0.008 and 0.001, respectively). However, no significant correlation was found among other subtype groups. CONCLUSIONS: Non-invasive vMRE demonstrated diagnostic efficiency in differentiating the nature of pulmonary neoplasm. vMRE is promising as a new method for clinical diagnosis.


Assuntos
Técnicas de Imagem por Elasticidade , Neoplasias Pulmonares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Técnicas de Imagem por Elasticidade/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Idoso , Movimento (Física) , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Estudos de Viabilidade
10.
Sci Rep ; 14(1): 15613, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38971907

RESUMO

Glioblastoma is the most common and aggressive primary malignant brain tumor with poor prognosis. Novel immunotherapeutic approaches are currently under investigation. Even though magnetic resonance imaging (MRI) is the most important imaging tool for treatment monitoring, response assessment is often hampered by therapy-related tissue changes. As tumor and therapy-associated tissue reactions differ structurally, we hypothesize that biomechanics could be a pertinent imaging proxy for differentiation. Longitudinal MRI and magnetic resonance elastography (MRE) were performed to monitor response to immunotherapy with a toll-like receptor 7/8 agonist in orthotopic syngeneic experimental glioma. Imaging results were correlated to histology and light sheet microscopy data. Here, we identify MRE as a promising non-invasive imaging method for immunotherapy-monitoring by quantifying changes in response-related tumor mechanics. Specifically, we show that a relative softening of treated compared to untreated tumors is linked to the inflammatory processes following therapy-induced re-education of tumor-associated myeloid cells. Mechanistically, combined effects of myeloid influx and inflammation including extracellular matrix degradation following immunotherapy form the basis of treated tumors being softer than untreated glioma. This is a very early indicator of therapy response outperforming established imaging metrics such as tumor volume. The overall anti-tumor inflammatory processes likely have similar effects on human brain tissue biomechanics, making MRE a promising tool for gauging response to immunotherapy in glioma patients early, thereby strongly impacting patient pathway.


Assuntos
Neoplasias Encefálicas , Modelos Animais de Doenças , Glioma , Imunoterapia , Imageamento por Ressonância Magnética , Animais , Camundongos , Glioma/diagnóstico por imagem , Glioma/terapia , Glioma/imunologia , Glioma/patologia , Imunoterapia/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/imunologia , Neoplasias Encefálicas/terapia , Neoplasias Encefálicas/patologia , Imageamento por Ressonância Magnética/métodos , Técnicas de Imagem por Elasticidade/métodos , Linhagem Celular Tumoral , Fenômenos Biomecânicos , Humanos , Camundongos Endogâmicos C57BL , Biomarcadores Tumorais/metabolismo
11.
J Appl Clin Med Phys ; : e14441, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38980059

RESUMO

BACKGROUND: Sjögren's syndrome (SS) is a common rheumatic disease for which finding the right imaging tool remains a challenge. PURPOSE: This study aimed to evaluate the performance of salivary gland ultrasonography (SGUS), shear wave elastography (SWE) and their combined use for the diagnosis of primary and secondary SS (pSS and sSS). METHODS: This retrospective study included patients with dry symptoms who underwent routine examinations between May 2019 and December 2023. Patients were categorized into the pSS (n = 41), sSS (n = 26), and control (n = 27) groups based on the American College of Rheumatology/European League Against Rheumatism classification criteria (2016). A comparison of SGUS and shear wave velocity (SWV) results was conducted among the three groups. The diagnostic capabilities of different ultrasound methods for SS were evaluated using receiver operating characteristic (ROC) curves and the area under the curve (AUC) for specificity. RESULTS: Compared to the control group, both the pSS (1.80 ± 1.03 vs. 0.67 ± 0.48, p < 0.001) and the sSS (1.85 ± 0.88 vs. 0.67 ± 0.48, p < 0.001) groups exhibited significantly elevated SGUS scores. However, there was no statistically significant difference between the pSS and sSS groups (p = 0.849). The SWV values in both the pSS and sSS groups were significantly higher than those in the control group (all p < 0.001). The AUC for diagnosing SS using only SGUS scores was 0.823 (95% confidence interval [CI]: 0.731-0.894). Combining SGUS scores and SWV values resulted in improved diagnostic accuracy (AUC: 0.883, 95% CI: 0.801-0.940). CONCLUSIONS: SGUS and SWE are pivotal in the diagnosis of Sjögren's syndrome, with their synergistic application poised to bolster diagnostic precision. This combined approach also furnishes substantial backing for the clinical assessment and management of Sjögren's syndrome.

12.
J Ultrasound Med ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38980145

RESUMO

OBJECTIVE: To describe the morphologic sonographic appearances and frequency of the "halo sign" in the setting of fat necrosis on shear wave elastography (SWE). METHODS: Patients with clinically suspected fat necrosis were prospectively scanned using SWE in addition to standard gray-scale and Doppler images. Cases were qualitatively grouped into one of three sonographic appearances: focal hypoechoic lesion with increased internal tissue stiffness ("focal stiffness"), focal hypoechoic lesion with isoechoic or hyperechoic periphery demonstrating increased tissue stiffness relative to the central hypoechoic lesion ("halo stiffness"), heterogeneously echogenic lesion with diffusely increased stiffness ("heterogeneous stiffness"). RESULTS: Exactly 19 patients met inclusion criteria (female n = 14; male n = 5). Shear wave velocities were recorded and retrospectively evaluated. The mean clinical follow-up was 11.4 months (range 3.0-25.5). Lesions demonstrated higher average tissue stiffness than background tissue (overall mass shear wave velocity 3.26 m/s, background 1.42 m/s, P < .001; lesion Young's modulus 40.85 kPa vs background 7.22 kPa, P < .001). The halo sign was identified in 10/19 (55%) patients. CONCLUSION: The halo sign is a potentially useful sign in the setting of fat necrosis seen in the majority of clinically suspected cases.

13.
Front Med (Lausanne) ; 11: 1388728, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38957299

RESUMO

Brain glioma, which is highly invasive and has a poor prognosis, is the most common primary intracranial tumor. Several studies have verified that the extent of resection is a considerable prognostic factor for achieving the best results in neurosurgical oncology. To obtain gross total resection (GTR), neurosurgery relies heavily on generating continuous, real-time, intraoperative glioma descriptions based on image guidance. Given the limitations of existing devices, it is imperative to develop a real-time image-guided resection technique to offer reliable functional and anatomical information during surgery. At present, the application of intraoperative ultrasound (IOUS) has been indicated to enhance resection rates and maximize brain function preservation. IOUS, which is promising due to its lower cost, minimal operational flow interruptions, and lack of radiation exposure, can enable real-time localization and precise tumor size and form descriptions while assisting in discriminating residual tumors and solving brain tissue shifts. Moreover, the application of new advancements in ultrasound technology, such as contrast-enhanced ultrasound (CEUS), three-dimensional ultrasound (3DUS), noninvasive ultrasound (NUS), and ultrasound elastography (UE), could assist in achieving GTR in glioma surgery. This article reviews the advantages and disadvantages of IOUS in glioma surgery.

14.
Pediatr Hematol Oncol ; : 1-13, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38978478

RESUMO

Increased liver stiffness (LS) can be result of increased liver iron concentration (LIC) which may not yet be reflected in the liver fibrotic status. The objective of our study was to examine relationship between hemochromatosis, LS, and serum ferritin level in transfusion-dependent patients. We recruited all 70 transfusion-dependent patients, whose median age was 15, referred for evaluating LIC status by magnetic resonance imaging (MRI) followed by two-dimensional ultrasonography shear wave elastography (2D-SWE). Thalassemia beta affected the majority of the patients. The optimal cut point for prediction of severe hemochromatosis using median SWE (kPa) and SWV (m/s) was ≥ 7.0 kPa and ≥ 1.54 m/s, respectively, with sensitivity of 0.76 (95% confidence interval [CI] 0.55, 0.91) and, specificity of 0.69 (95%CI 0.53, 0.82). When combing the optimal cut point of SWE (kPa) at ≥ 7.0 and serum ferritin ≥ 4123 ng/mL, the sensitivity increased to 0.84 (95%CI 0.64, 0.95) with specificity of 0.67 (95%CI 0.50, 0.80), positive predictive value (PPV) of 0.60 (95%CI 0.42, 0.76), and negative predictive value (NPV) of 0.88 (95%CI 0.71, 0.96). Simultaneous tests of 2D-SWE and serum ferritin for prediction of severe hemochromatosis showed the highest sensitivity of 84% (95%CI 0.64-0.95), as compared to 2D-SWE alone at 76% (95%CI 0.55, 0.91) or serum ferritin alone at 44% (95%CI 0.24-0.65). We recommend measuring both 2D-SWE and serum ferritin in short interval follow up patients. Adding 2D-SWE to management guideline will help in deciding for aggressive adjustment of iron chelating medication and increased awareness of patients having severe hemochromatosis.

15.
PeerJ ; 12: e17677, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38974410

RESUMO

Background: The study aims to evaluate the diagnostic efficacy of contrast-enhanced ultrasound (CEUS) and shear-wave elastography (SWE) in detecting small malignant breast nodules in an effort to inform further refinements of the Breast Imaging Reporting and Data System (BI-RADS) classification system. Methods: This study retrospectively analyzed patients with breast nodules who underwent conventional ultrasound, CEUS, and SWE at Gongli Hospital from November 2015 to December 2019. The inclusion criteria were nodules ≤ 2 cm in diameter with pathological outcomes determined by biopsy, no prior treatments, and solid or predominantly solid nodules. The exclusion criteria included pregnancy or lactation and low-quality images. Imaging features were detailed and classified per BI-RADS. Diagnostic accuracy was assessed using receiver operating characteristic curves. Results: The study included 302 patients with 305 breast nodules, 113 of which were malignant. The diagnostic accuracy was significantly improved by combining the BI-RADS classification with CEUS and SWE. The combined approach yielded a sensitivity of 88.5%, specificity of 87.0%, positive predictive value of 80.0%, negative predictive value of 92.8%, and accuracy of 87.5% with an area under the curve of 0.877. Notably, 55.8% of BI-RADS 4A nodules were downgraded to BI-RADS 3 and confirmed as benign after pathological examination, suggesting the potential to avoid unnecessary biopsies. Conclusion: The integrated use of the BI-RADS classification, CEUS, and SWE enhances the accuracy of differentiating benign and malignant small breast nodule, potentially reducing the need for unnecessary biopsies.


Assuntos
Neoplasias da Mama , Meios de Contraste , Técnicas de Imagem por Elasticidade , Ultrassonografia Mamária , Humanos , Feminino , Técnicas de Imagem por Elasticidade/métodos , Estudos Retrospectivos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Pessoa de Meia-Idade , Adulto , Ultrassonografia Mamária/métodos , Idoso , Sensibilidade e Especificidade , Curva ROC , Mama/diagnóstico por imagem , Mama/patologia
16.
Abdom Radiol (NY) ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38990302

RESUMO

PURPOSE: To assess the feasibility and performance of MR elastography (MRE) for quantifying liver fibrosis in patients with and without hepatic iron overload. METHODS: This retrospective single-center study analyzed 139 patients who underwent liver MRI at 3 Tesla including MRE (2D spin-echo EPI sequence) and R2* mapping for liver iron content (LIC) estimation. MRE feasibility and diagnostic performance between patients with normal and elevated LIC were compared. RESULTS: Patients with elevated LIC (21%) had significantly higher MRE failure rates (24.1% vs. 3.6%, p < 0.001) compared to patients with normal LIC (79%). For those with only insignificant to mild iron overload (LIC < 5.4 mg/g; 17%), MRE failure rate did not differ significantly from patients without iron overload (8.3% vs. 3.6%, p = 0.315). R2* predicted MRE failure with fair accuracy at a threshold of R2* ≥ 269 s-1 (LIC of approximately 4.6 mg/g). MRE showed good diagnostic performance for detecting significant (≥ F2) and severe fibrosis (≥ F3) in patients without (AUC 0.835 and 0.900) and with iron overload (AUC 0.818 and 0.889) without significant difference between the cohorts (p = 0.884 and p = 0.913). For detecting cirrhosis MRE showed an excellent diagnostic performance in both groups (AUC 0.944 and 1.000, p = 0.009). CONCLUSION: Spin-echo EPI MRE at 3 Tesla is feasible in patients with mild iron overload with good to excellent performance for detecting hepatic fibrosis with a failure rate comparable to patients without iron overload.

17.
Artigo em Inglês | MEDLINE | ID: mdl-38951430

RESUMO

PURPOSE: We investigated the diagnostic performance of two-dimensional shear wave elastography (2D-SWE) and attenuation imaging (ATI) in detecting fibrosis and steatosis in patients with chronic liver disease (CLD), comparing them with established methods. METHODS: In 190 patients with CLD, 2D-SWE and vibration-controlled transient elastography (VCTE) were used for liver stiffness measurement (LSM), and ATI and controlled attenuation parameter (CAP) were used for steatosis quantification. The correlations between these new and established methods were analyzed. RESULTS: Significant correlations were found between 2D-SWE and VCTE (r = 0.78, P < 0.001), and between ATI and CAP (r = 0.70, P < 0.001). Liver stiffness tended to be lower with 2D-SWE compared with that with VCTE, especially in cases with higher LSM, and ATI was less influenced by skin-capsular distance than CAP. Area under the receiver-operating characteristics curves (AUCs) and optimal cut-offs of 2D-SWE for diagnosing liver fibrosis stages F2, F3, and F4 were 0.73 (8.7 kPa), 0.79 (9.1 kPa), and 0.88 (11.6 kPa), respectively. The AUCs and optimal cut-offs of ATI for diagnosing hepatic steatosis grades S1, S2, and S3 were 0.91 (0.66 dB/cm/MHz), 0.80 (0.79 dB/cm/MHz), and 0.88 (0.86 dB/cm/MHz), respectively. A subgroup analysis of 86 patients with metabolic dysfunction-associated steatotic liver disease also demonstrated good performance for 2D-SWE and ATI. CONCLUSION: 2D-SWE and ATI performed comparably with conventional VCTE and CAP in evaluating CLD, offering reliable alternatives for diagnosing liver fibrosis and steatosis.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38987197

RESUMO

BACKGROUND AND AIM: Understanding the dynamics of serum Mac-2 binding protein glycosylation isomer (M2BPGi) remains pivotal for hepatitis C virus (HCV) patients' post-sustained virologic response (SVR12) through direct-acting antivirals (DAAs). METHODS: We compared areas under receiver operating characteristic curves (AUROCs) of M2BPGi, FIB-4, and APRI and assess M2BPGi cutoff levels in predicting fibrosis stages of ≥F3 and F4 utilizing transient elastography in 638 patients. Variations in M2BPGi levels from pretreatment to SVR12 and their association with pretreatment alanine transaminase (ALT) levels and fibrosis stage were investigated. RESULTS: The AUROCs of M2BPGi were comparable to FIB-4 in predicting ≥F3 (0.914 vs 0.902, P = 0.48) and F4 (0.947 vs 0.915, P = 0.05) but were superior to APRI in predicting ≥F3 (0.914 vs 0.851, P = 0.001) and F4 (0.947 vs 0.857, P < 0.001). Using M2BPGi cutoff values of 2.83 and 3.98, fibrosis stages of ≥F3 and F4 were confirmed with a positive likelihood ratio ≥10. The median M2BPGi change was -0.55. Patients with ALT levels ≥5 times ULN or ≥F3 demonstrated more pronounced median decreases in M2BPGi level compared to those with ALT levels 2-5 times ULN and <2 times ULN (-0.97 vs -0.68 and -0.44; P < 0.001) or with < F3 (-1.52 vs -0.44; P < 0.001). CONCLUSIONS: Serum M2BPGi is a reliable marker for advanced hepatic fibrosis. Following viral clearance, there is a notable M2BPGi decrease, with the extent of reduction influenced by ALT levels and fibrosis stage.

19.
BMC Gastroenterol ; 24(1): 221, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38987694

RESUMO

BACKGROUND: Obesity has become a major global public health challenge. Studies examining the associations between different obesity patterns and the risk of nonalcoholic fatty liver disease (NAFLD) are limited. This study aimed to investigate the relationships between different obesity patterns and the risk of NAFLD in a large male population in the US. METHODS: Data from the 2017 to March 2020 National Health and Nutrition Examination Survey (NHANES) were utilized. Liver steatosis and fibrosis were assessed with FibroScan using the controlled attenuation parameter (CAP) and liver stiffness measurements (LSM). Steatosis was identified with a CAP value of 248 dB/m or higher. Abdominal obesity was defined by a waist circumference (WC) of 102 cm or more for males and 88 cm or more for females. Overweight was defined as a body mass index (BMI) of 24.0 kg/m2 and above. General obesity was identified with a BMI of 28.0 kg/m2 or higher. Obesity status was categorized into four types: overweight, general obesity, abdominal obesity, and combined obesity. Multivariate logistic regression, adjusting for potential confounders, was used to examine the link between obesity patterns and NAFLD risk. Subgroup analysis further explored these associations. RESULTS: A total of 5,858 adults were included. After multivariable adjustment, compared to the normal weight group, the odds ratios (ORs) [95% confidence interval (CI)] for NAFLD in individuals with overweight, general obesity, abdominal obesity, and combined obesity were 6.90 [3.74-12.70], 2.84 [2.38-3.39], 3.02 [2.02-4.51], and 9.53 [7.79-11.64], respectively. Subgroup analysis showed the effect of different obesity patterns on NAFLD risk was stable among individuals with different clinical conditions. In the fully adjusted multivariate logistic regression model, WC was positively associated with NAFLD risk (OR: 1.48; 95% CI: 1.42-1.53; P < 0.001). WC also demonstrated strong discriminatory ability for NAFLD in Receiver Operating Characteristic (ROC) analysis, achieving an Area Under the Curve (AUC) of 0.802. CONCLUSIONS: Different patterns of obesity are risk factors for NAFLD. An increase in WC significantly increased NAFLD risk. More attention should be paid to preventing different patterns of obesity among adults.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Inquéritos Nutricionais , Obesidade , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Hepatopatia Gordurosa não Alcoólica/complicações , Masculino , Estudos Transversais , Obesidade/complicações , Obesidade/epidemiologia , Pessoa de Meia-Idade , Adulto , Fatores de Risco , Feminino , Índice de Massa Corporal , Circunferência da Cintura , Estados Unidos/epidemiologia , Obesidade Abdominal/complicações , Obesidade Abdominal/epidemiologia , Obesidade Abdominal/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/epidemiologia , Sobrepeso/complicações , Sobrepeso/epidemiologia
20.
BMC Gastroenterol ; 24(1): 218, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38977950

RESUMO

BACKGROUND: Studies attempted to estimate MASLD-related advanced fibrosis (AF) and cirrhosis (MC) prevalence utilized tests with low positive predictive value (PPV) which overestimates prevalence. AGILE3 + and 4 scores were developed to increase the PPV of both; respectively. In this study, we used these scores to assess the prevalence of AF and MC. METHODS: Participants aged ≥ 18 years with VCTE exam in the NHANES 2017-2018 cycle were included. We excluded pregnant women, patients with excessive alcohol intake, hepatitis B/C, and ALT or AST > 500 IU/L. MASLD was defined with CAP score > 248 dB/m. MASLD subjects with AGILE 3 + score of ≥ 0.68 and AGILE 4 score of ≥ 0.57 were considered to have advanced fibrosis and cirrhosis; respectively. AGILE 3 + of 0.45-0.67 and AGILE 4 of 0.25-0.57 were grey zone, whereas AGILE 3 + < 0.45 and AGILE 4 < 0.25 were considered a rule-out. RESULTS: 1244 subjects were included in the final analysis. The Median age was 53 (51.4-54.6) years, 55.6% were male, median BMI was 33.8 kg/m2 and 41.1% had T2DM. Based on AGILE 3+, 80.3% of the MASLD population were at low risk for AF and 11.5% were in grey zone. The prevalence of AF due to MASLD was 8.1% corresponding to 4.5 million Americans. Based on AGILE 4 score, 96.5% of the MASLD population were at low risk for cirrhosis and 2.4% were in the grey zone. The prevalence of MASLD-cirrhosis was 1.1% corresponding to 610,000 Americans. CONCLUSION: Our results suggest that approximately 4.5 million people in the U.S. have AF and 0.6 million have cirrhosis due to MASLD.


Assuntos
Cirrose Hepática , Inquéritos Nutricionais , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Prevalência , Cirrose Hepática/epidemiologia , Estados Unidos/epidemiologia , Fígado Gorduroso/epidemiologia , Fígado Gorduroso/complicações , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...