Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 931
Filtrar
1.
Expert Rev Med Devices ; : 1-7, 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39376030

RESUMO

BACKGROUND: Various types of needles are available to perform endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). A relatively new needle for EBUS-TBNA, the Acquire Fine Needle Biopsy (FNB) device, has recently become available. METHODS: Consecutive subjects with lymphadenopathy >1 cm undergoing EBUS-TBNA were randomized to the Acquire 22-G EBUS-FNB needle and the standard 22-G EBUS-TBNA needle groups. RESULTS: A total of 86 subjects were randomized (43 in each group). The diagnostic yield of EBUS-TBNA was similar between the two groups: (36/43) 83.7% in the 22-G EBUS-FNB group and (34/43) 79.1% in the standard 22-G EBUS group (p = 0.58). The sampling adequacy, stations sampled, number of stations sampled, number of needle passes, and mean duration of the procedure between the two groups were also similar. Visible tissue clot core was obtained in a significantly greater proportion of subjects in the 22-G EBUS-FNB group (93.0% vs 46.5%, p < 0.001). Visibly bloody samples were more frequent in the 22-G EBUS-FNB group (74.4% vs 51.2%, p = 0.03). There was no difference in the complication rates between the two groups (p = 0.15). CONCLUSION: We did not observe a difference in the diagnostic yield of the Acquire 22-G EBUS-FNB needle compared with the standard 22-G EBUS needle. CLINICAL TRIAL REGISTRATION: Clinical Trial Registry of India (CTRI) https://ctri.nic.in/ (CTRI/2021/08/035589).

2.
Artigo em Inglês | MEDLINE | ID: mdl-39370862

RESUMO

INTRODUCTION: Pulmonary endoscopy occupies a central role in Interventional Pulmonology and is frequently the mainstay of diagnosis of respiratory disease, in particular lung malignancy. Older techniques such as rigid bronchoscopy maintain an important role in central airway obstruction. Renewed interest in the peripheral pulmonary nodule is driving major advances in technologies to increase the diagnostic accuracy and advance new potential endoscopic therapeutic options. AREAS COVERED: This paper describes the role of pulmonary endoscopy, in particular ultrasound in the diagnosis and staging of lung malignancy. We will explore the recent expansion of ultrasound to include endoscopic ultrasound - bronchoscopy (EUS-B) and combined ultrasound (CUS) techniques. We will discuss in detail the advances in the workup of the peripheral pulmonary nodule.We performed a non-systematic, narrative review of the literature to summarize the evidence regarding the indications, diagnostic yield, and safety of current bronchoscopic sampling techniques. EXPERT OPINION: EBUS/EUS-B has revolutionized the diagnosis and staging of thoracic malignancy resulting in more accurate assessment of the mediastinum compared to mediastinoscopy alone, thus reducing the rate of futile thoracotomies. Although major advances in the assessment of the peripheral pulmonary nodule have been made, the role of endoscopy in this area requires further clarification and investigation.

3.
Chest ; 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39343294

RESUMO

BACKGROUND: Endobronchial Ultrasound-Guided Transbronchial Aspiration (EBUS-TBNA) has become the standard for initial lung cancer diagnosis and staging. Previous guidelines have generally focused on the "when" and "how" of EBUS-TBNA; however, little guidance is available on handling and processing specimens during and after acquisition to help optimize both diagnostic yield and tissue integrity for ancillary studies. This document examines the available literature on EBUS-TBNA specimen processing and handling. METHODS: Rigorous methodology was applied to provide a trustworthy evidence-based guideline and expert panel report. Panelists developed key clinical questions utilizing the PICO (population, intervention, comparator, and outcome) format, addressing specific topics in EBUS-TBNA specimen processing. MEDLINE (via PubMed) and the Cochrane Library were systematically searched to identify relevant literature, supplemented by manual searches. References were screened for inclusion with document evaluation tools to assess the quality of included studies, extract meaningful data, and grade the level of evidence to support each recommendation or suggestion. RESULTS: Our systematic review and critical analysis of the literature of the 9 PICO questions related to handling and processing EBUS-TBNA specimens resulted in nine evidence-based statements. CONCLUSIONS: Evidence of the handling and processing of EBUS-TBNA specimens varies in strength but is satisfactory in some areas to guide clinicians in certain aspects of specimen handling. Additional research in many aspects of specimen handling and processing is needed to help improve our knowledge base.

4.
BMC Infect Dis ; 24(1): 1017, 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-39304805

RESUMO

BACKGROUND: The diagnosis of peripheral isolated nodular lesions that are suspected as pulmonary tuberculosis (PTB) is challenging, which are not easily accessible via conventional bronchoscopy. This study evaluated the combined use of Xpert MTB/RIF assay and endobronchial ultrasonography with a guide sheath (EBUS-GS) for detecting MTB infection in peripheral lung bands, for early detection of PTB. METHODS: The clinical data of 232 patients with suspected peripheral nodular PTB who underwent EBUS-GS between June 2020 and October 2023 were retrospectively reviewed. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the curve (AUC) of acid-fast bacilli smear, culture, Xpert MTB/RIF assay, and pathological examination were calculated. To assess diagnostic accuracy, the results of the four methods were directly compared with the final clinical diagnosis. RESULTS: In total, 146 and 86 patients were clinically diagnosed with peripheral nodular PTB and non-PTB, respectively. The sensitivity, specificity, PPV, NPV, and AUC values of combined Xpert MTB/RIF assay and EBUS-GS were 47.26%, 100.0%, 100.0%, 52.76%, and 0.74; those of acid-fast bacilli smear were 8.22%, 97.67%, 85.71%, 38.53%, and 0.53; those of culture were 31.51%, 100.0%, 100.0%, 46.24%, and 0.66; and those of pathological examination were 23.97%, 97.67%, 94.59%, 43.08%, and 0.61, respectively. CONCLUSION: The diagnostic accuracy of the combined Xpert MTB/RIF assay and EBUS-GS was significantly better than that of other conventional tests. Hence, this novel technique can be routinely applied for diagnosing and managing peripheral nodular PTB.


Assuntos
Mycobacterium tuberculosis , Sensibilidade e Especificidade , Tuberculose Pulmonar , Humanos , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/microbiologia , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Mycobacterium tuberculosis/isolamento & purificação , Mycobacterium tuberculosis/genética , Adulto , Idoso , Broncoscopia/métodos , Endossonografia/métodos , Técnicas de Diagnóstico Molecular/métodos , Valor Preditivo dos Testes , Pulmão/microbiologia , Pulmão/diagnóstico por imagem , Pulmão/patologia
5.
Respir Med ; 234: 107805, 2024 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-39265839

RESUMO

BACKGROUND: Tuberculosis frequently poses diagnostic challenge when it presents as a peripheral pulmonary lesion (TB-PPL). The growing use of radial endobronchial ultrasound (rEBUS) for PPL biopsy highlights the need to identify predictive factors for TB-PPL, which is crucial for procedure safety. METHODS: A six-year retrospective review at our institution on adult patients with TB and malignant-PPL diagnosed from rEBUS procedure from October 1, 2016, to December 31, 2022. Clinical, radiological, procedural, histological and microbiological data were extracted and analysed. RESULTS: 387 PPLs were included in our cohort, 32 % were TB-PPL and 68 % were malignant-PPL. The median age was 63 (IQR 55-70) years, with the TB-PPL group significantly younger. The median size of the target lesion was 2.90 (IQR 2.26-4.00) cm. The overall rEBUS diagnostic yield was 85.3 %, with a 1.3 % pneumothorax risk. Multivariate analysis identified independent predictors for TB-PPL, including age <60 years (adj OR 2.635), target lesion size <2 cm (adj OR 2.385), upper lobe location (adj OR 2.020), presence of a cavity on pre-procedural CT (adj OR 4.186), and presence of rEBUS bronchogram (adj OR 2.722). These variables achieved an area under the curve of 0.729 (95 % CI 0.673-0.795) with a diagnostic accuracy of 75.49 % (95 % CI 70.68-79.88). CONCLUSIONS: Despite non-specific radiological findings in TB-PPL, our study identifies younger age, target lesion size less than 2 cm, upper lobe location, the presence of cavitation, and rEBUS bronchogram were independent clinical predictors for TB-PPL. This prediction model potentially helps mitigate the risk of accidental TB exposure during bronchoscopic procedures. A future prospective cohort study to validate these findings is essential to allow proper triaging of patient planning for rEBUS procedure.

6.
Ther Adv Respir Dis ; 18: 17534666241277668, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39235434

RESUMO

BACKGROUND: Incidental and screen-detected pulmonary nodules are common. The increasing capabilities of advanced diagnostic bronchoscopy will increase bronchoscopists' procedural volume necessitating optimization of procedural scheduling and workflow. OBJECTIVES: The objectives of this study were to determine total time in the procedure room, total bronchoscopy procedure time, and robotic-assisted bronchoscopy procedure time longitudinally and per specific procedure performed. DESIGN: A single-center observational study of all consecutive patients undergoing shape-sensing robotic-assisted bronchoscopy (RAB) biopsy procedures for the evaluation of pulmonary lesions with variable probability for malignancy. METHODS: Chart review to collect patient demographics, lesion characteristics, and procedural specifics. Descriptive and comparative statistics are reported. RESULTS: Actual bronchoscopy procedure time may decrease with increased institutional experience over time, however, there is limited ability to reduce non-bronchoscopy related time within the procedure room. The use of cone beam computed tomography (CBCT), rapid on-site evaluation (ROSE), and performance of staging endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) in a single procedure are each associated with additional time requirements. CONCLUSION: Institutional procedural block times should adapt to the nature of advanced diagnostic bronchoscopy procedures to allow for the accommodation of new modalities such as RAB combined with other technologies including radial endobronchial ultrasound, CBCT, ROSE, and staging linear EBUS. Identifying institutional median procedural times may assist in scheduling and ideal block time utilization.


Times necessary to perform robotic assisted bronchoscopy biopsy procedures at a single hospitalBackground: Lung lesions and nodules are commonly seen on computed tomography (CT) scans. With advances in technology, more of these lesions are being biopsied with robotic assisted bronchoscopy (RAB) procedures, leading to increased demand. Health care providers who perform these procedures have finite available time in which they must accommodate all their procedures. Understanding procedure times is necessary to fully utilize schedules. Methods and aims overview: We describe our experience of 5 pulmonologists performing 700 robotic assisted bronchoscopies at a single hospital. Our aim is to describe the time needed for the robotic bronchoscopies over time and with specific procedures. Results and conclusion: We find that as more robotic assisted bronchoscopies are performed, the overall procedure time may decrease. Using cone beam computed tomography during the procedure, having on- site pathology review of biopsies, and obtaining biopsies of lymph nodes may lengthen the procedure time. The time spent preparing the patient for the procedure excluding the bronchoscopy remained stable. Understanding the time necessary based on what is performed during the procedure will allow it to be scheduled for the appropriate amount of time. As a result, procedure days can be fully optimized, minimizing scheduling impacts on patients and health care workers.


Assuntos
Broncoscopia , Neoplasias Pulmonares , Procedimentos Cirúrgicos Robóticos , Humanos , Broncoscopia/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/diagnóstico , Fatores de Tempo , Duração da Cirurgia , Tomografia Computadorizada de Feixe Cônico , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Fluxo de Trabalho , Estudos Retrospectivos , Adulto
7.
Sci Rep ; 14(1): 21334, 2024 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-39266613

RESUMO

Previous studies have shown that rapid on-site evaluation (ROSE) improves the diagnostic yield of bronchoscopy using endobronchial ultrasound with a guide sheath (EBUS-GS) for peripheral pulmonary lesions (PPL). While ROSE of imprint cytology from forceps biopsy has been widely discussed, there are few reports on ROSE of brush cytology. This study investigated the utility of ROSE of brush cytology during bronchoscopy. We retrospectively analyzed data from 214 patients who underwent bronchoscopy with EBUS-GS for PPL. The patients in the ROSE group had significantly higher diagnostic sensitivity through the entire bronchoscopy process than in the non-ROSE group (96.8% vs. 83.3%, P = 0.002). The use of ROSE significantly increased the sensitivity of brush cytology with Papanicolaou staining (92.9% vs. 75.0%, P < 0.001). When ROSE was sequentially repeated on brushing specimens, initially negative ROSE results converted to positive in 79.5% of cases, and the proportion of specimens with high tumor cell counts increased from 42.1 to 69.0%. This study concludes that ROSE of brush cytology improves the diagnostic accuracy of bronchoscopy and enhances specimen quality through repeated brushing.


Assuntos
Broncoscopia , Neoplasias Pulmonares , Humanos , Broncoscopia/métodos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/diagnóstico por imagem , Avaliação Rápida no Local , Endossonografia/métodos , Citodiagnóstico/métodos , Idoso de 80 Anos ou mais , Adulto , Sensibilidade e Especificidade , Citologia
8.
Radiother Oncol ; 201: 110547, 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39332638

RESUMO

BACKGROUND & PURPOSE: Local treatment of oligometastases has been found to improve survival and prognosis. Stereotactic body radiotherapy (SBRT) has emerged as a treatment option for oligometastases but its use in ultra-central (UC) areas can cause significant toxicity and mortality. Fiducial markers (FM) can be used to improve SBRT accuracy, and can be inserted in the central thorax using linear endobronchial ultrasound (EBUS) bronchoscopy. Outcomes of FM-guided SBRT for UC thoracic oligometastases is unknown. METHODS: A single-centre retrospective study investigating the feasibility, safety and outcomes of both linear EBUS-inserted FMs and subsequent FM-guided SBRT for UC-oligometastatic disease. Motion analyses of FMs were also performed. RESULTS: Thirty outpatients underwent 32 EBUS-FM insertion procedures with 100 % success, and no major procedural mortality or morbidity. Minor complications were 4.8 % incidence of delayed FM-displacement. UC FM-guided SBRT was completed in 20 patients with 99.9 % fractions delivered. Median SBRT dose delivered was 40 Gy over a median of 8 fractions. Majority of adverse events were Grade 1 and there was no SBRT-related mortality. Local control with SBRT was 95 %, with overall survival at 1-year and 3-years of 90 % and 56.3 % respectively. Median overall survival after SBRT was 43.6 months. FM movements in UC areas were recorded being greatest in the superior-inferior axis. CONCLUSION: Combined linear EBUS sampling and FM-insertion in UC thoracic oligometastatic disease is feasible and safe. UC-SBRT to oligometastases using FM guidance was found to have minimal complications and associated with moderate survival up to 3 years post-treatment.

9.
Endosc Ultrasound ; 13(4): 239-247, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39318751

RESUMO

Background and Objectives: Radial endobronchial ultrasound (R-EBUS) plays an important role during transbronchial sampling of peripheral pulmonary lesions (PPLs). However, existing navigational bronchoscopy systems provide no guidance for R-EBUS. To guide intraoperative R-EBUS probe manipulation, we aimed to simulate R-EBUS images of PPLs from preoperative computed tomography (CT) data using deep learning. Materials and Methods: Preoperative CT and intraoperative ultrasound data of PPLs in 250 patients who underwent R-EBUS-guided transbronchial lung biopsy were retrospectively collected. Two-dimensional CT sections perpendicular to the biopsy path were transformed into ultrasonic reflection and transmission images using an ultrasound propagation model to obtain the initial simulated R-EBUS images. A cycle generative adversarial network was trained to improve the realism of initial simulated images. Objective and subjective indicators were used to evaluate the similarity between real and simulated images. Results: Wasserstein distances showed that utilizing the cycle generative adversarial network significantly improved the similarity between real and simulated R-EBUS images. There was no statistically significant difference in the long axis, short axis, and area between real and simulated lesions (all P > 0.05). Based on the experts' evaluation, a median similarity score of ≥4 on a 5-point scale was obtained for lesion size, shape, margin, internal echoes, and overall similarity. Conclusions: Simulated R-EBUS images of PPLs generated by our method can closely mimic the corresponding real images, demonstrating the potential of our method to provide guidance for intraoperative R-EBUS probe manipulation.

10.
Front Med (Lausanne) ; 11: 1409160, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39206167

RESUMO

Background: The incidence of adverse events during endobronchial ultrasound is low. Nevertheless, it is unclear, whether patients with impaired pulmonary function have an increased risk of respiratory events during the intervention. Methods: A monocentric prospective observational study was performed at the Department of Respiratory Medicine, University Hospital Frankfurt/Main, Germany. Adult patients undergoing an endobronchial ultrasound examination with propofol-sedation were included. Pre-interventional screening included pulmonary function testing, laboratory tests and electrocardiogram. The occurrence of hypercapnia >55 mmHg or reduced oxygen saturation <85% was defined as a respiratory event was recorded and compared between patients with normal and impaired pulmonary function tests. Results: In total, 126 patients were included. Pulmonary function testing revealed a median FEV1 of 2.2 l (range 0.4-6.04l) and a predicted FEV1 of 79.5% (range 20-127.8%) respectively. The median FVC was 3.0 l (range 0.87-7.28l), the median predicted FVC was 82% (range 31.4-128.4%). In 72 examinations (60%) pCO2 levels >55 mmHg were measured. Transient oxygen desaturation <85% occurred in 31 cases (25.8%). The Mann Whitney U-test showed a significantly lower FEV1 (% predicted value) in patients with respiratory events (p = 0.007). ROC analysis identified a predicted FEV1 of 78.5% as the optimal cut-off with a sensitivity of 58% and a specificity of 71%. Using Z-score instead of predicted values, there was no significant association between a lower Z- score of FEV or FVC and hypercapnic or hypoxic events. However, both a lower absolute value of FEV1/FVC and a lower Z-score of the FEV1/FVC index were associated with the occurrence of respiratory events. In binary logistic regression analysis, we could not demonstrate any association with other relevant parameters (age, BMI, sedation dosage, sedation duration, or ASA-score). Conclusions: An impaired forced expiratory volume is associated with the frequency of respiratory events during endobronchial ultrasound examination under propofol-sedation.

11.
Bioengineering (Basel) ; 11(8)2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39199767

RESUMO

The addition of intravenous (i.v.) chemotherapy to i.v. immunotherapy for patients with lung cancer results in improved overall survival but is limited by synergistic side effects and an unknown, highly variable final cytotoxic dose within the tumor. The synergy between i.v. chemo- and immunotherapies is hypothesized to occur as a result of cell injury caused by chemotherapy, a mechanism demonstrated to drive antigen presentation within the tumor microenvironment. Intratumoral delivery of chemotherapy may thus be optimized to maximize tumor cell injury. To assess the balance between the damage versus the death of tumor cells, we developed a computational model of intratumoral dynamics within a lung cancer tumor for three different chemotherapy agents following direct injection as a function of location and number of injection sites. We based the model on the morphology of a lung tumor obtained from a thoracic CT scan. We found no meaningful difference in the extent of tumor cell damage between a centrally injected versus peripherally injected agent, but there were significant differences between a single injection versus when the total dose was apportioned between multiple injection sites. Importantly, we also found that the standard chemotherapeutic concentrations used for intravenous administration were effective at causing cell death but were too high to generate significant cell injury. This suggests that to induce maximal tumor cell injury, the optimal concentration should be several orders of magnitude lower than those typically used for intravenous therapy.

12.
BMC Infect Dis ; 24(1): 861, 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39187759

RESUMO

BACKGROUND: Microbiological diagnosis of pulmonary tuberculosis (PTB) is hampered by a low pathogen burden, low compliance and unreliable sputum sampling. Although endobronchial ultrasound-guided transbronchoscopic lung biopsy (EBUS-TBLB) has been found to be useful for the assessment of intrapulmonary nodules in adults, few data are available for the clinical diagnosis of pulmonary tuberculosis. Here, we evaluated EBUS-TBLB as a diagnostic procedure in adult patients with radiologically suspected intrapulmonary tuberculous nodules. METHODS: This was a retrospective analysis of patients admitted with pulmonary nodules between January 2022 and January 2023 at Hangzhou Red Cross Hospital. All patients underwent EBUS-TBLB, and lung biopsy samples were obtained during hospitalization. All samples were tested for Mycobacterium tuberculosis using acid‒fast smears, Bactec MGIT 960, Xpert MTB/RIF, next-generation sequencing (NGS), and DNA (TB‒DNA) and RNA (TB‒RNA). The concordance between different diagnostic methods and clinical diagnosis was analysed via kappa concordance analysis. The diagnostic efficacy of different diagnostic methods for PTB was analysed via ROC curve. RESULTS: A total of 107 patients were included in this study. Among them, 86 patients were diagnosed by EBUS-TBLB, and the overall diagnostic rate was 80.37%. In addition, 102 enrolled patients had benign lesions, and only 5 were diagnosed with lung tumours. Univariate analysis revealed that the diagnostic rate of EBUS-TBLB in pulmonary nodules was related to the location of the probe. The consistency analysis and ROC curve analysis revealed that NGS had the highest concordance with the clinical diagnosis results (agreement = 78.50%, κ = 0.558) and had the highest diagnostic efficacy for PTB (AUC = 0.778). In addition, Xpert MTB/RIF + NGS had the highest concordance with the clinical diagnosis results (agreement = 84.11%, κ = 0.667) and had the highest efficacy in the diagnosis of PTB (AUC = 0.826). CONCLUSION: EBUS-TBLB is a sensitive and safe method for the diagnosis of pathological pulmonary nodules. Xpert MTB/RIF combined with NGS had the highest diagnostic efficacy and can be used in the initial diagnosis of PTB.


Assuntos
Broncoscopia , Mycobacterium tuberculosis , Tuberculose Pulmonar , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/patologia , Tuberculose Pulmonar/microbiologia , Broncoscopia/métodos , Mycobacterium tuberculosis/isolamento & purificação , Adulto , Idoso , Pulmão/patologia , Pulmão/microbiologia , Pulmão/diagnóstico por imagem , Biópsia Guiada por Imagem/métodos , Sensibilidade e Especificidade
13.
J Imaging ; 10(8)2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39194979

RESUMO

Endobronchial ultrasound (EBUS) is used in the minimally invasive sampling of thoracic lymph nodes. In lung cancer staging, the accurate assessment of mediastinal structures is essential but challenged by variations in anatomy, image quality, and operator-dependent image interpretation. This study aimed to automatically detect and segment mediastinal lymph nodes and blood vessels employing a novel U-Net architecture-based approach in EBUS images. A total of 1161 EBUS images from 40 patients were annotated. For training and validation, 882 images from 30 patients and 145 images from 5 patients were utilized. A separate set of 134 images was reserved for testing. For lymph node and blood vessel segmentation, the mean ± standard deviation (SD) values of the Dice similarity coefficient were 0.71 ± 0.35 and 0.76 ± 0.38, those of the precision were 0.69 ± 0.36 and 0.82 ± 0.22, those of the sensitivity were 0.71 ± 0.38 and 0.80 ± 0.25, those of the specificity were 0.98 ± 0.02 and 0.99 ± 0.01, and those of the F1 score were 0.85 ± 0.16 and 0.81 ± 0.21, respectively. The average processing and segmentation run-time per image was 55 ± 1 ms (mean ± SD). The new U-Net architecture-based approach (EBUS-AI) could automatically detect and segment mediastinal lymph nodes and blood vessels in EBUS images. The method performed well and was feasible and fast, enabling real-time automatic labeling.

14.
Respiration ; : 1-13, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39137742

RESUMO

INTRODUCTION: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) can be limited by the inadequacy of intact tissues, especially in patients with lymphoma, sarcoidosis, and lymph node tuberculosis. A novel technique called transbronchial node biopsy (TBNB) by forceps or cryoprobe has been proposed and studied to improve specimen quality and diagnostic yield. We performed a systematic review of studies describing the safety and sensitivity of EBUS-TBNB versus EBUS-TBNA in diagnosing intrathoracic lymphadenopathy/masses. METHODS: We systematically searched MEDLINE, Embase, Cochrane, and China National Knowledge Infrastructure to identify studies focusing on the application of EBUS-TBNB for diagnosis of intrathoracic lymphadenopathy. The quality of each study was evaluated using the QUADAS-2 tool. Using inverse-variance (I-V) weighting, we performed a meta-analysis of diagnostic yield estimations. We also reviewed the complications related to the procedure. RESULTS: Thirteen studies were included in the final analysis. The meta-analysis yielded a pooled overall diagnostic yield of 77.80% (939/1,207) for EBUS-TBNA and 86.01% (834/958) for EBUS-TBNB, with an inverse-variance-weighted odds ratio of 3.13 (95% confidence interval [CI], 1.61-6.01; p = 0.0008) and I2 of 82%. The pooled diagnostic yield of EBUS-TBNB versus EBUS-TBNA for the diagnosis of malignancy (including primary lung cancer and extrapulmonary malignancy) was 84.53% (590/698) for EBUS-TBNA and 90.84% (476/524) for EBUS-TBNB, with an I-V-weighted OR of 2.33 (95% CI, 1.15-4.74; p = 0.02) and I2 of 64%. The pooled diagnostic yield of EBUS-TBNB versus EBUS-TBNA for the diagnosis of benignancy was 71.19% (252/354) for EBUS-TBNA and 86.62% (233/269) for EBUS-TBNB, with an I-V-weighted OR of 4.39 (95% CI, 2.00-9.65; p = 0.002) and I2 of 59%. The overall complications included bleeding (n = 11, 0.90%), pneumomediastinum (n = 6, 0.49%), pneumothorax (n = 6, 0.49%), pneumonia (n = 4, 0.33%), respiratory failure (n = 1, 0.08%), and haemoptysis (n = 1, 0.08%). The funnel plot analysis illustrated no major publication bias. CONCLUSIONS: EBUS-TBNB improves the overall diagnostic yield of sampling intrathoracic lymphadenopathy and mass lesions relative to EBUS-TBNA. The complication rate of EBUS-TBNB is higher than that of EBUS-TBNA but reportedly lower than that of surgical biopsies.

15.
Expert Rev Respir Med ; 18(8): 581-595, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39093300

RESUMO

INTRODUCTION: In the past two decades, bronchoscopy of peripheral pulmonary lesions (PPLs) has improved its diagnostic yield due to the combination of various instruments and devices. Meanwhile, the application is complex and intertwined. AREAS COVERED: This review article outlines strategies in diagnostic bronchoscopy for PPLs. We summarize the utility and evidence of key instruments and devices based on the results of clinical trials. Future perspectives of bronchoscopy for PPLs are also discussed. EXPERT OPINION: The accuracy of reaching PPLs by bronchoscopy has improved significantly with the introduction of combined instruments such as navigation, radial endobronchial ultrasound, digital tomosynthesis, and cone-beam computed tomography. It has been accelerated with the advent of approach tools such as newer ultrathin bronchoscopes and robotic-assisted bronchoscopy. In addition, needle aspiration and cryobiopsy provide further diagnostic opportunities beyond forceps biopsy. Rapid on-site evaluation may also play an important role in decision making during the procedures. As a result, the diagnostic yield of bronchoscopy for PPLs has improved to a level comparable to that of transthoracic needle biopsy. The techniques and technologies developed in the diagnosis will be carried over to the next step in the transbronchial treatment of PPLs in the future.


Assuntos
Broncoscopia , Pneumopatias , Humanos , Broncoscopia/instrumentação , Broncoscopia/métodos , Pneumopatias/diagnóstico , Pneumopatias/diagnóstico por imagem , Pneumopatias/patologia , Pulmão/patologia , Pulmão/diagnóstico por imagem , Broncoscópios , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/diagnóstico por imagem
16.
Respiration ; : 1-6, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39173596

RESUMO

INTRODUCTION: Endobronchial ultrasound-guided transbronchial needle aspiration remains the gold standard for the diagnosis of mediastinal pathologies. Its greatest limitation has been the low diagnostic yield in lymphoproliferative disorders as well as insufficient samples for molecular testing. Transesophageal examinations using an EBUS scope have helped increase the diagnostic yield by allowing for additional biopsies of paraesophageal and intra-abdominal lesions. Similarly, the novel approach of transbronchial mediastinal cryobiopsy has further increased the yield by providing larger and better-preserved biopsies. Both complimentary techniques have shown great individual feasibility and safety. However, the feasibility of transesophageal cryobiopsies in the evaluation of mediastinal pathologies remains a subject of debate. AIM: The aim of the study was to investigate the safety and feasibility of transesophageal EBUS-guided mediastinal cryobiopsies performed at our center. METHODS: We conducted a retrospective review of 30 patients who underwent mediastinal cryobiopsy through the esophagus at our institution between October 2023 and March 2024. Data on patient demographics, diagnostic yield, and complications were collected and analyzed. RESULTS: The mean patient age was 43 years, with a gender distribution of 60% male and 40% female. The primary indications included suspicion of lymphoproliferative disorders, suspected sarcoidosis, and malignancies with paraesophageal lesions. The overall diagnostic yield was 93%. No major complications were noted in any of the patients. CONCLUSION: Transesophageal mediastinal cryobiopsy appears to be a promising complimentary technique for mediastinal evaluation with a relatively high diagnostic yield and favorable safety profile. However, further studies with larger cohorts are warranted to validate the findings at our institution.

17.
Expert Rev Med Devices ; 21(9): 859-867, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39107968

RESUMO

BACKGROUND: The diagnosis of peripheral pulmonary lesions (PPLs) remains challenging. Despite advancements in guided transbronchial biopsy (TBB) techniques, diagnostic yields haven't reached ideal levels. Optical coherence tomography (OCT) has been developed for application in pulmonary diseases, yet no data existed evaluating effectiveness in diagnosing PPLs. RESEARCH DESIGN AND METHODS: This study included patients who underwent OCT and radial endobronchial ultrasound (R-EBUS)-guided TBB. OCT and R-EBUS imaging features were analyzed to differentiate between benign and malignant PPLs and subtypes of lung cancer. RESULTS: A total of 89 patients were included in this study. The diagnostic yield of OCT-guided TBB stood at 56.18%, R-EBUS-guided TBB was 83.15% (P<0.01). The accuracy of OCT to judge the nature of lesions was 92.59%, while R-EBUS was 77.92%. The accuracy of OCT in predicting squamous carcinoma (SCC) and adenocarcinoma were both 91.30%. CONCLUSIONS: Although the diagnostic yield of OCT-guided TBB fell short of that achieved by R-EBUS, OCT possessed the capability to judge the nature of lesions and guide the pathological classification of malignant lesions. Further extensive prospective studies are necessary to thoroughly assess the characteristics of this procedure. CLINICAL TRIAL REGISTRATION: https://register.clinicaltrials.gov/ identifier is NCT06419114.


Assuntos
Biópsia Guiada por Imagem , Neoplasias Pulmonares , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Projetos Piloto , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Biópsia Guiada por Imagem/métodos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Broncoscopia/métodos , Adulto , Pneumopatias/diagnóstico por imagem , Pneumopatias/patologia , Idoso de 80 Anos ou mais
18.
Rev Mal Respir ; 41(8): 549-561, 2024 Oct.
Artigo em Francês | MEDLINE | ID: mdl-39179425

RESUMO

INTRODUCTION: While mediastinoscopy is considered the gold standard for mediastinal node sampling, it is to some extent being superseded by endobronchial ultrasound. The objective of this study was to evaluate the different practices in our center regarding mediastinal lymph node sampling in lung cancer patients. METHODS: Data were collected from patients having undergone mediastinal lymph node sampling by video-assisted-mediastinoscopy (VM) or by endobronchial ultrasound (EBUS) in our center between August 2020 and July 2023. The modalities of the two procedures and their diagnostic accuracy were analyzed, as was their evolution over time. RESULTS: The 362 patients comprised 217 who were sampled by EBUS and 145 by VM. Overall, the procedures became more frequent, with EBUS tending to supersede VM. The number of harvested lymph nodes gradually grew, and less unforeseen lymph node invasion and upstaging occurred. CONCLUSION: The arrival in our center of endobronchial ultrasound yielded an overall increase of lymph node sampling despite a decrease in the number of mediastinoscopy procedures performed. Reinforced compliance with guidelines is needed to improve the diagnostic accuracy of these techniques and to better ensure quality of care.


Assuntos
Neoplasias Pulmonares , Linfonodos , Metástase Linfática , Mediastinoscopia , Mediastino , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico , Linfonodos/patologia , Linfonodos/diagnóstico por imagem , Mediastinoscopia/métodos , Mediastino/patologia , Mediastino/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Metástase Linfática/diagnóstico , Metástase Linfática/patologia , Estudos Retrospectivos , Endossonografia/métodos , Endossonografia/normas , Adulto , Idoso de 80 Anos ou mais , Padrões de Prática Médica/estatística & dados numéricos , Padrões de Prática Médica/normas , Padrões de Prática Médica/tendências , Broncoscopia/métodos , Broncoscopia/estatística & dados numéricos , Broncoscopia/normas , Excisão de Linfonodo/métodos
19.
J Thorac Dis ; 16(7): 4217-4228, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39144333

RESUMO

Background: Endobronchial ultrasound (EBUS)-guided mediastinal/hilar cryobiopsy (MedCryoBx) is a relatively new modality, being combined with EBUS-transbronchial needle aspiration (TBNA) to improve yield in the diagnosis of intrathoracic adenopathy. This meta-analysis aims to investigate the diagnostic yield of MedCryoBx versus EBUS-TBNA for intrathoracic adenopathy. Methods: We conducted a systematic search using Google Scholar, Embase, and PubMed/MEDLINE for studies about a diagnosis of intrathoracic adenopathy using MedCryoBx and EBUS-TBNA. Two authors separately reviewed studies for inherent bias using the Quality Assessment Data Abstraction and Synthesis-2 (QUADAS-2) tool. Inverse Variance weighting for random effects methodology was used for meta-analysis. Pooled diagnostic yields overall and for subgroups were estimated. Complications of MedCryoBx were reviewed. Results: Ten studies with 844 patients undergoing either biopsy procedure were in the final analysis. A total of 554 patients underwent MedCryoBx and 704 patients EBUS-TBNA. Meta-analysis showed a pooled diagnostic yield of 91% (504 of 554) for MedCryoBx and 81% (567 of 704) for EBUS-TBNA, with odds ratio (OR) of 2.5 [95% confidence interval (CI): 1.6 to 3.91; P<0.001], with I2 of 20%. Subgroup analysis for benign conditions showed increased diagnostic yield with OR of 7.95 (91% MedCryoBx versus 58% EBUS-TBNA, P<0.001) with an I2 of 25%. Subgroup analysis for lymphoma showed a statistically significant increase in pooled diagnostic yield with OR of 11.48 (87% MedCryoBx versus 29% EBUS-TBNA, P=0.001). Mild bleeding (36.5%) without any intervention was the most common complication. Bleeding requiring intervention (0.7%) was noted in patients. Pneumothorax (0.4%) and pneumomediastinum (0.4%) were less common in this analysis. Conclusions: MedCryoBx is a very promising tool for the diagnosis of intrathoracic adenopathy. It has improved diagnostic yield over EBUS-TBNA in benign and possibly lymphoproliferative diseases, but less so in lung cancer. The complication rates with MedCryoBx are comparable to EBUS-TBNA.

20.
Ther Adv Respir Dis ; 18: 17534666241273017, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39157955

RESUMO

BACKGROUND: Radial probe endobronchial ultrasound (radial EBUS) is widely used to diagnose pulmonary lesions; however, the diagnostic value of radial EBUS-guided transbronchial biopsy (TBB) varies, and its complications (especially the risk of bleeding) are not properly understood. OBJECTIVES: In this study, we evaluated the diagnostic performance and rate of complication of this procedure, and investigated the risk factors associated with the procedure-related bleeding events. DESIGN: A retrospective cohort study. METHODS: This was a retrospective study that included consecutive patients who underwent radial EBUS-guided TBB. Radial EBUS was performed under moderate sedation in inpatients or outpatients. The severity of bleeding was graded using the standardized definitions of bleeding. RESULTS: Of 133 patients (median age, 69 years; men 57.1%) included, 41 were outpatients (30.8%). The diagnostic accuracy, sensitivity, and specificity for malignancy were 76.1% (89/117), 71.1% (69/97), and 100% (20/20), respectively. The diagnostic accuracy ranged from 66.9% to 79.0%, depending on the classification of undiagnosed cases as either false negatives or true negatives. Twenty-seven patients (20.3%) developed complications (pneumothorax, 3; pneumonia, 5; complicated pleural effusion, 2; bleeding event grade 2 or higher, 21). Of the 41 outpatients, two developed complications (pneumothorax without intervention, 1; grade 2 bleeding event, 1). Of the 21 patients (15.8%) with procedure-related bleeding events, 18 had grade 2, and three had grade 3 bleeding complications. In multivariate analysis, a large size of ⩾30 mm (adjusted odds ratio (OR), 5.09; p = 0.03) and central lesion (adjusted OR, 3.67; p = 0.03) were significantly associated with the risk of grade 2 or higher bleeding events. CONCLUSION: Our results suggest that radial EBUS-guided TBB is an accurate and safe method for diagnosing pulmonary lesions. Clinically significant procedure-related bleeding was rare. The central location and larger size (⩾30 mm) of pulmonary lesions were risk factors for grade 2 or higher bleeding events.


Assuntos
Broncoscopia , Hemorragia , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Fatores de Risco , Pessoa de Meia-Idade , Hemorragia/etiologia , Broncoscopia/efeitos adversos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Endossonografia/efeitos adversos , Endossonografia/métodos , Ultrassonografia de Intervenção/efeitos adversos , Idoso de 80 Anos ou mais , Neoplasias Pulmonares/patologia , Valor Preditivo dos Testes , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA