Resultados 1 - 20 de 191
Filtrar
1.
Clin Chem Lab Med ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38753471

RESUMO

OBJECTIVES: Even in the current era of hematology analyzer automation and peripheral equipment, quality control sample measurement remains a manual task, leading to variability in quality control data and increased workload. In this study, we evaluated the performance of quality control measurement using the BT-50 Transportation Unit (BT-50, Sysmex, Kobe, Japan), equipped with a scheduled automatic quality control function, to ensure measurement accuracy and streamline the workflow of hematology testing. METHODS: We evaluated the automatic measurement performance of quality control samples using the BT-50 for six representative blood test parameters: WBC (white blood cell), RBC (red blood cell), HGB (hemoglobin), HCT (hematocrit), PLT (platelet), and RET% (reticulocyte percent). We evaluated the equivalence and compared measurement accuracy between the BT-50 and the manual method. We then compared the variability to other laboratories and confirmed the stability of quality control samples. We also evaluated changes in workflow and staff resources before and after the introduction of the BT-50. RESULTS: The quality control measurement results for the BT-50 and the manual method were found to be equivalent for all six parameters. The variability measured by the BT-50 was lower for some parameters compared to the manual method. Furthermore, the workflow was streamlined by reducing manual processes, resulting in increased efficiency. CONCLUSIONS: We confirmed the performance of quality control measurements using the schedule function of the BT-50. Introducing the BT-50 reduced the operator's workload, improved operational efficiency, and promoted the standardization of quality control measurements.

2.
J Clin Lab Anal ; 38(8): e25037, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38619294

RESUMO

BACKGROUND: In newborns, elevated nucleated red blood cell (NRBC) levels can be associated with enhanced erythropoietic stress and might be predictive for adverse outcome. Also, the presence of NRBC in peripheral blood might lead to erroneous enumeration results of white blood cells in automated hematology analyzers. We aimed to assess the comparability of the Sysmex XN 1000 to manual slide reviews and correlation of NRBC with inflammation markers. METHODS: Specimens of 3397 children under 1 year were compared by automated and microscopic NRBC enumeration. Additionally, potential correlations between NRBC and age and inflammation markers were examined. RESULTS: Overall, there was good correlation (r = 0.97) between automated (range: 0%-3883%) and microscopic enumeration (range: 0%-3694%) of NRBC with high comparability up to a NRBC value of 200% and an increase in the variation between the two methods with increasing NRBC numbers. When 94 samples with ≤ 200% NRBC and ≥ 30% divergence between methods were separately reanalyzed with respect to overlapping cell populations in their scattergrams, Sysmex would have generated unrecognized incorrect automated results in 47 samples, corresponding to 1.4% of total study samples. NRBC counts were negatively correlated to age, but not to inflammation markers. CONCLUSION: Sysmex XN 1000 is highly precise in the enumeration of NRBC in children under 1 year up to counts of 200% and might replace time-intense manual counting in routine diagnostics. In the setting of neonatal and intensive care diagnostics, microscopic control and supervision of scattergrams are highly recommended for any automated NRBC enumeration processes.


Assuntos
Eritroblastos , Humanos , Lactente , Eritroblastos/citologia , Recém-Nascido , Contagem de Eritrócitos/métodos , Feminino , Masculino , Automação Laboratorial/métodos , Microscopia/métodos
4.
Int J Lab Hematol ; 46(1): 63-71, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37731006

RESUMO

INTRODUCTION: The Atellica Hema (Siemens Healthineers, Tarrytown, NY, USA) is a new generation multi-parameter analyzer for full blood count, 6-part differential and reticulocyte testing by impedance variation and fluorescence flow cytometry. In this study, we verified the whole blood and limited body fluid modes of the Atellica Hema 580. METHODS: We evaluated precision, linearity, carry-over, throughput and performed a method comparison to assess the performance of the Atellica Hema 580. For comparison of the Atellica Hema 580 with the Sysmex XN-1000 (Sysmex, Kobe, Japan), 140 samples from adult and pediatric patients including both normal and abnormal hematology profiles were analyzed in parallel. RESULTS: The Atellica Hema 580 demonstrated acceptable imprecision within the manufacturer's specifications for whole blood and body fluid modes, good linearity for high and low ranges and no significant carryover. The full blood count, differential and reticulocyte correlated well with the Sysmex XN-1000, except for mean cell hemoglobin concentration, basophil and large immature cells. The optical platelet count, reflexed in 34 samples with a platelet count <150 × 109 /l, showed a strong correlation with the fluorescent platelet count on the Sysmex XN-1000. The morphology flagging efficiency was 92% for white blood cells, 95% for red blood cells and 87% for platelets. CONCLUSION: The Atellica Hema 580 showed good analytical performance and workflow efficiency for a wide range of patient samples.


Assuntos
Hematologia , Adulto , Humanos , Criança , Contagem de Células Sanguíneas/métodos , Hematologia/métodos , Contagem de Plaquetas/métodos , Leucócitos , Plaquetas , Reprodutibilidade dos Testes
5.
Clin Chem Lab Med ; 62(5): 958-966, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38000045

RESUMO

OBJECTIVES: White blood cell (WBC)-related flags are essential for detecting abnormal cells including blasts in automated hematology analyzers (AHAs). Cell population data (CPD) may characterize each WBC population, and customized CPD rules can be also useful for detecting blasts. We evaluated the performance of WBC-related flags, customized CPD rules, and their combination for detecting blasts on the Beckman Coulter DxH 900 AHA (DxH 900, Beckman Coulter, Miami, Florida, USA). METHODS: In a total of 239 samples from patients with hematologic diseases, complete blood count on DxH 900 and manual slide review (MSR) were conducted. The sensitivity, specificity, and efficiency of the five WBC-related flags, nine customized CPD rules, and their combination were evaluated for detecting blasts, in comparison with MSR. RESULTS: Blasts were detected by MSR in 40 out of 239 (16.7 %) samples. The combination of flags and CPD rules showed the highest sensitivity compared with each of flags and CPD rules for detecting blasts (97.5 vs. 72.5 % vs. 92.5 %). Compared with any flag, the combination of flags and CPD rules significantly reduced false-negative samples from 11 to one for detecting blasts (27.5 vs. 2.5 %, p=0.002). CONCLUSIONS: This is the first study that evaluated the performance of both flags and CPD rules on DxH 900. The customized CPD rules as well as the combination of flags and CPD rules outperformed WBC-related flags for detecting blasts on DxH 900. The customized CPD rules can play a complementary role for improving the capability of blast detection on DxH 900.


Assuntos
Doenças Hematológicas , Hematologia , Humanos , Contagem de Células Sanguíneas , Doenças Hematológicas/diagnóstico , Leucócitos , Contagem de Leucócitos
7.
Ann Clin Lab Sci ; 53(4): 653-660, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37625826

RESUMO

OBJECTIVE: We evaluated the performance of the Alinity hq automated analyzer (Abbott Laboratories, Diagnostics Division, Hematology, Santa Clara, CA, USA). In addition, we determined the reference ranges for the red blood cell (RBC) research parameters. METHOD: The precision and stability of the instrument were measured for all complete blood count (CBC) parameters. We compared the CBC results between the Alinity hq and the DxH800 (Beckman Coulter, Miami, FL, USA) and the ADVIA 2120 (Siemens Healthcare Diagnostics, Tarrytown, NY, USA). The white blood cell (WBC) differential results were verified by manual differential counts. We determined the reference ranges of RBC research parameters among healthy adults. RESULTS: The Alinity hq analyzer demonstrated good within-run and between-day precision for all CBC parameters. The calculated correlation coefficients (r) indicated that Alinity hq-determined values of WBC, RBC, platelet (PLT) counts, hemoglobin (HGB), hematocrit (HCT), and mean corpuscular volume (MCV) were in very good concordance (r>0.95) when compared with results from the DxH800 and the ADVIA 2120. The Alinity hq WBC differential counts were comparable with the manual differential counts, and the results of neutrophil counts by Alinity hq correlated well. Lymphocyte and monocyte count correlated well in samples without blasts. CONCLUSIONS: The Alinity hq presented good analytical performance and showed good correlation compared with other hematology analyzers and manual differential counts.


Assuntos
Índices de Eritrócitos , Eritrócitos , Adulto , Humanos , Valores de Referência , Hematócrito , Contagem de Leucócitos
8.
Int J Lab Hematol ; 45(6): 869-874, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37571820

RESUMO

INTRODUCTION: Hemoglobin-based oxygen carriers, for example HBOC-201 (Hemopure), are aimed to bridge acute anemia when blood transfusion is not available or refused by the patient. However, since HBOC-201 appears free in plasma, it interferes with laboratory tests. This study presents an overview of HBOC-201 interference on four commonly used hematology analyzers and suggests treatment monitoring possibilities. METHODS: Blood samples were spiked with therapeutic doses of HBOC-201 and nine hematology parameters were measured with the Sysmex XN-20, Siemens Advia 2120i, Abbott Alinity Hq and Abbot Cell Dyn Sapphire hematology analyzers. The results were compared to control samples and the bias was determined. RESULTS: Most parameters, including all cell counts, hematocrit and MCV, showed a non-significant bias compared to control. However, the standard, total hemoglobin (Hb) measurement as well as MCH and MCHC showed poor agreement with control, as HBOC-201 was included in this measurement. Yet, the flow cytometry-based Hb method quantified intracellular Hb in spiked samples, excluding HBOC-201. CONCLUSION: Of all included hematology parameters, only total Hb and the associated MCH and MCHC suffered from interference. In contrast, the flow cytometry-based Hb measurement provided an accurate measure of intracellular Hb. The difference between total Hb and cellular Hb represents the HBOC-201 concentration and can be used to monitor HBOC-201 treatment.


Assuntos
Hematologia , Hemoglobinas , Humanos , Hemoglobinas/análise , Testes Hematológicos , Transfusão de Sangue , Oxigênio
9.
Cardiovasc Diagn Ther ; 13(3): 465-473, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37405010

RESUMO

Background: Capillary blood is a common specimen type used for infant blood routine tests. Until now, this specimen type could only be tested with the manual mode in hematology analyzers. Manual sample mixing and loading increases the amount labor force and can be more easily affected by human factors. This study was designed to investigate the proficiency of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing. Methods: The complete blood count (CBC) results for capillary blood were compared between the automatic and manual modes. Special types of samples, including samples with high or low volume, thalassemia red cells, high fibrinogen, high hematocrit (HCT), or high triglyceride levels, were compared and evaluated. The intraclass correlation coefficient (ICC) was used to define the agreement between the 2 modes. The industry standard Analytical Quality Specifications for Routine Tests in Clinical Hematology (WS/T 406-2012), published by the National Health Commission of China, was used to evaluate the correlation between the results from the 2 modes. Results: There was good correlation between the automatic and manual modes for every type of sample, and the ICCs were all higher than 0.9. Except for high HCT or high triglyceride samples, there were no differences found between the 2 modes based on the WS/T 406-2012 standard. Conclusions: This new automatic mode utilized in the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood yielded the same results as the manual mode except in the case of samples with high HCT or triglycerides. Capillary blood might be routinely tested automatically with hematology analyzers in the near future, which might reduce the labor required and improve standardization.

10.
Cancers (Basel) ; 15(9)2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37173954

RESUMO

Myelodysplastic syndromes (MDS) are common malignant disorders with a poor prognosis. It is necessary to search for new rapid diagnostic methods to detect MDS patients with cytogenetic changes. The aim of the study was to assess new hematological neutrophil- and monocyte- related parameters I then bone marrow of MDS patient with and without cytogenetic changes. A total of 45 patients with MDS, including 17 patients with cytogenetic changes, were examined. The study was conducted using the Sysmex XN-Series hematological analyzer. New neutrophil and monocyte parameters, such as immature granulocytes (IG), neutrophil reactivity intensity (NEUT-RI), neutrophil granularity intensity (NEUT-GI), neutrophil size (NE-FSC) and neutrophil/monocyte data relating to granularity, activity and volume (NE-WX/MO-WX, NE-WY/MO-WY, NE-WZ/MO-WZ, MO-X, MO-Y, MO-Z) were evaluated. We observed higher median proportions of NE-WX, NE-WY, NE-WZ, and IG counts in MDS patients with cytogenetic changes than in patients without cytogenetic changes. The NE-FSC parameter was lower in MDS patients with cytogenetic changes than in patients without cytogenetic changes. The combination of new neutrophil parameters was found to be a new successful approach in distinguishing MDS patients with cytogenetic changes from patients without cytogenetic changes. It appears that there may be unique neutrophil parameter signatures associated with an underlying mutation.

11.
Ann Lab Med ; 43(5): 418-424, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37080742

RESUMO

Background: Delta checks increase patient safety by identifying automated hematology analyzer errors. International standards and guidelines for the complete blood count (CBC) delta check method have not been established. We established an effective, practical CBC delta check method and criteria. Methods: We assessed five delta check methods for nine CBC items (Hb, mean corpuscular volume, platelet count, white blood cell [WBC] count, and five-part WBC differential counts) using 219,804 blood samples from outpatients and inpatients collected over nine months. We adopted the best method and criteria and evaluated them using 42,652 CBC samples collected over two weeks with a new workflow algorithm for identifying test errors and corrections for Hb and platelet count. Results: The median delta check time interval was 1 and 21 days for inpatients and outpatients (range, 1-20 and 1-222 days), respectively. We used delta values at 99.5% as delta check criteria; the criteria varied among the five methods and between outpatients and inpatients. The delta percent change (DPC)/reference range (RR) rate performed best as the delta check for CBC items. Using the new DPC/RR rate method, 1.7% of total test results exceeded the delta check criteria; the retesting and resampling rates were 0.5% and 0.001%, respectively. Conclusions: We developed an effective, practical delta check method, including RRs and delta check time intervals, and delta check criteria for nine CBC items. The criteria differ between outpatients and inpatients. Using the new workflow algorithm, we can identify the causes of criterion exceedance and report correct test results.


Assuntos
Hematologia , Humanos , Contagem de Células Sanguíneas/métodos , Contagem de Leucócitos , Contagem de Plaquetas , Controle de Qualidade , Hematologia/métodos
13.
Lab Med ; 54(1): e10-e13, 2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-35713611

RESUMO

OBJECTIVE: Although small red blood cells are a well-known analytical pitfall that could cause artifactual increase of the platelet count, limited information is available on the accuracy of impedance platelet counting in cases with microcytosis. The aim of this study is to assess the accuracy of impedance platelet counting in the presence of small red blood cells, and to establish the optimal mean corpuscular volume (MCV) cutoff to endorse fluorescence platelet counting. METHODS: In this study, platelet counts estimated by the impedance method on the Sysmex XN9000 analyzer (Sysmex, Kobe, Japan) were compared with those provided by the fluorescence method. The accuracy of impedance platelet counting was assessed. Receiver operating characteristic curve was used to evaluate the performance of MCV in predicting falsely increased platelet counts. RESULTS: There was a tendency for the impedance method to overestimate the platelet count in samples with 70 fL < MCV ≤ 80 fL, 60 fL < MCV ≤ 70 fL, MCV ≤ 60 fL. Receiver operating characteristic curve analysis showed that a 73.5fL cutoff of MCV was highly sensitive in predicting falsely increased platelet counts. CONCLUSION: In cases with MCV < 73.5 fL, we strongly suggest that the platelet counts obtained by the impedance method on the Sysmex XN9000 analyzer should be checked and corrected by fluorescence counting.


Assuntos
Hematologia , Humanos , Contagem de Plaquetas/métodos , Eritrócitos , Índices de Eritrócitos , Reprodutibilidade dos Testes
14.
EJHaem ; 3(4): 1126-1134, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36467845

RESUMO

We compared a point-of-care HemoScreen hematology analyzer to an automated Sysmex XN analyzer for complete blood count (CBC) and white blood cell (WBC) differential, and evaluated its capacity to detect leukocyte abnormalities. A total of 100 K2-EDTA whole blood samples, median age 56 years (2 months to 92 years), were compared. For CBC and WBC differential we compared 74 samples with no confirmed abnormal leukocytes. For 26 samples both analyzers gave flagging regarding leukocytes and the accuracy of the flagging was compared. Abnormal leukocytes were confirmed with manual microscopy (200 cells). HemoScreen CBC and WBC differential were highly comparable to Sysmex XN for most of the essential parameters (r = 0.909-0.975). More variation was seen for basophil and monocyte counts (r = 0.452 and 0.753, respectively). Sysmex XN gave more false WBC abnormal flagging (n = 15 altogether) compared to HemoScreen. In addition, Sysmex XN, as well as HemoScreen, gave false WBC flagging for eight samples confirmed normal. The samples verified by microscopy review to truly contain leukocyte abnormalities (n = 18) were flagged abnormal with both analyzers. The specificity for analyzer flagging was 72% and 88% for Sysmex XN and HemoScreen, respectively. HemoScreen hematology analyzer is essentially comparable to Sysmex XN for CBC and WBC differential analysis. Most importantly, HemoScreen detected all the samples confirmed to include abnormal leukocytes. HemoScreen was less prone for false WBC flagging compared to Sysmex XN, thereafter requiring less microscopy review. These abilities increase its utility in small health care units. Studies with a larger number of abnormal leukocyte samples are needed to confirm HemoScreen performance.

15.
Int J Lab Hematol ; 44(6): 1050-1059, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36380469

RESUMO

INTRODUCTION: Assessing the percentage of reticulocytes (%Retic) is useful for diagnosing and treating blood diseases that present with anaemia. The Celltac G+™ hematology analyzer (HA) uses a novel reticulocyte identification method that involves metachromatic nucleic acid staining with acridine orange and crossover analysis of emission light of DNA/RNA (determination of red cells, nucleic acid-containing cells, and platelets, RNP Determination™). The red and green fluorescence generated by stained single-stranded RNA and double-stranded DNA express immaturity and morphological abnormality of erythrocytes by detecting erythrocyte RNA and DNA content. METHODS: The basic performance of the test automated analyzer (TAA) Celltac G+ was evaluated and compared with the flow cytometry reference method and the comparative automated analyzer (CAA) XN-1000/2000™. In addition, its precision, limit of quantity (LoQ), linearity, analytical measurement interval (AMI), accuracy, and comparability and the effects of interfering substances were evaluated. RESULTS: Evaluation of %Retic by the TAA demonstrated good precision and linearity. The AMI was confirmed from 0.02 to 8.23, and the LoQ in %Retic as the coefficient of variation within an 11% limit (SD, within a 0.01 limit) was 0.14. TAA correlated well with the reference method and routine HA (CAA). Some deviations were found between TAA and CAA in DNA measurements of erythrocytes from abnormal samples. CONCLUSION: Celltac G+ uses a novel measurement principle and can assess erythrocyte immaturity independent of DNA contents. It represents a new HA that provides novel, useful information on immaturity and morphological abnormality of erythrocytes.


Assuntos
Hematologia , Ácidos Nucleicos , Humanos , Reticulócitos , RNA , Reprodutibilidade dos Testes , DNA , Coloração e Rotulagem
16.
Diagnostics (Basel) ; 12(11)2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36359430

RESUMO

Background: Eligibility criteria for blood donation require hemoglobin levels of ≥12.5 g/dL for women and ≥13.5 g/dL for men, and a platelet count of ≥180 × 109/L. Screening methods before donation should ensure high accuracy, precision, and ease in operation. We assessed the performance, precision, and repeatability of the Horiba Micros ES 60 (Horiba) compared to the Beckman Coulter DXH 800. Methods: Performance was compared by testing samples for each of the 11 devices across 6 sites in the Transfusion Service of Friuli Venezia Giulia Region, Italy. We measured precision by calculating the coefficient of variation (CV), concordance with ρ-Pearson's correlation coefficient, and accuracy with F-tests. The intra-assay agreement was examined in the 11 devices, and repeatability was performed by using CV and the Kruskal−Wallis test. Results: The precision of Horiba was acceptable. Overall, ρ-Pearson's coefficients indicated a strong correlation and positive relationship between all variables. The Bland−Altman plots showed that most of the differences lay within the limits of agreement. All CV were below the reference threshold for all the parameters. Finally, the Kruskal−Wallis test reported non-significant statistical differences for all parameters, except platelet count (p < 0.000). Conclusions: Horiba is adequate for routine pre-donation screening. The intra-assay agreement further demonstrates the accuracy of the device.

17.
Asian J Transfus Sci ; 16(1): 78-82, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36199413

RESUMO

BACKGROUND: Screening of hemoglobin (Hb) before blood donation is one among the vital tests. It is performed to select a blood donor to prevent the collection of blood from an anemic person. However, no accurate, cost-effective, reliable, and standardized method is available to estimate Hb. OBJECTIVE: The aim is to evaluate the efficacy of filter paper cyanmethemoglobin (FPCH) method with the automated hematology analyzer in the estimation of Hb concentration for screening of a suitable donor. METHODOLOGY: This was a cross-sectional study in which the blood samples of 2000 patients visiting KLE's Dr. Prabhakar Kore Charitable Hospital, Belagavi, were collected in vials and directly estimated for Hb using automated hematology analyzer. To evaluate the efficacy of FPCH, 20 µL of blood sample was transferred onto Whatman filter paper and dried at room temperature. After drying, it was placed in 5 mL of Drabkin's solution for 30 min. Optical density was estimated by measuring the absorbance. Data were analyzed using SPSS version 20. The correlation coefficient, paired t-test, and difference between the means of both the methods were calculated. RESULTS: The mean Hb estimated by FPCH was 11.25 g/dL and automated hematology analyzer gave 11.35 g/dL. The difference in the means of both the methods was 0.1 g/dL. Paired t-test was done to test the level of significance and the result was 8.151 (95% confidence interval: 0.08-0.13 g/dL, P < 0.001). The correlation coefficient was found to be 0.976 (P < 0.001). CONCLUSION: FPCH is an efficient method, which is comparable to the automated hematology analyzers for Hb estimation. It could be used as an alternative screening tool for detection of Hb in a blood donation camp.

18.
Ann Transl Med ; 10(17): 922, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36172102

RESUMO

Background: Erythrocyte sedimentation rate (ESR) is a new reporting parameter of the BC-720 auto hematology analyzer; however, no biological reference interval for healthy adults has been established for this parameter. Methods: Outpatients or hospitalized patients with ESR test orders were selected. The ESR was measured by the standard method of ESR (Westergren) recommended by the International Council for Standardization in Hematology (ICSH), the BC-720 hematology analyzer, and the LBY-XC40B auto ESR analyzer. The data were statistically analyzed and compared among different methods. The repeatability and carryover rate (CR) of the BC-720 were assessed in randomly selected samples for each range segment. Blood Samples from three hospitals in China were collected, and the reference interval of the BC-720 ESR was determined. Results: The ESR results measured by the BC-720 correlated well with the Westergren method (r=0.957, y = 0.359 + 1.016x), and there was no significant difference between these two methods (P>0.05). The correlation between LBY-XC40B auto ESR analyzer and Westergren was y = 1 + 1.25x and r=0.856. The BC-720 ESR has good repeatability [standard deviation (SD) ≤1 mm/h, coefficient of variation (CV) ≤5%], and the CR was less than 1%. The 95th percentile of the biological reference interval for BC-720 ESR is 15 mm/h for men and 24 mm/h for women. Conclusions: The Mindray BC-720 ESR showed high accuracy and good repeatability, which provided a faster, safer, and more reliable method to measure ESR. The reference intervals for BC-720 ESR could guide better clinical decisions for the laboratories utilizing this new method.

19.
Parasitol Int ; 91: 102648, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35988900

RESUMO

Rapid diagnostic tests (RDTs) based on immunochromatographic detection of Plasmodium falciparum histidine-rich protein 2 (HRP2) have been frequently used for malaria diagnosis. The HRP2-based RDTs are highly sensitive and easy to use; however, their sensitivity may be low in detecting P. falciparum strains carrying deletion of the pfhrp2 and pfhrp3 genes encoding HRP2 and HRP3, respectively. The automated hematology analyzer XN-31, developed by Sysmex (Kobe, Japan) to aid in malaria diagnosis, has higher sensitivity than RDTs owing to a unique automated nucleic acid staining technology that has shown great potential in clinical settings. In this study, we compared the performance of the XN-31 analyzer and two RDTs to detect pfhrp2- and/or pfhrp3-deleted parasites cultured in vitro. The analyses showed that the analyzer was not only as sensitive to pfhrp2- and/or pfhrp3-deleted strains as it was to the wild-type strain but also had higher sensitivity than the RDTs. These results suggested that the XN-31 analyzer is useful for rapid and reliable detection of pfhrp2- and/or pfhrp3-deleted parasites in clinical settings.


Assuntos
Hematologia , Malária Falciparum , Antígenos de Protozoários/genética , Antígenos de Protozoários/metabolismo , Histidina/metabolismo , Humanos , Japão , Malária Falciparum/diagnóstico , Malária Falciparum/parasitologia , Plasmodium falciparum/genética , Plasmodium falciparum/metabolismo , Proteínas de Protozoários/genética , Proteínas de Protozoários/metabolismo
20.
Biosensors (Basel) ; 12(7)2022 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-35884246

RESUMO

This article first reviews scientific meanings of single-cell analysis by highlighting two key scientific problems: landscape reconstruction of cellular identities during dynamic immune processes and mechanisms of tumor origin and evolution. Secondly, the article reviews clinical demands of single-cell analysis, which are complete blood counting enabled by optoelectronic flow cytometry and diagnosis of hematologic malignancies enabled by multicolor fluorescent flow cytometry. Then, this article focuses on the developments of optoelectronic flow cytometry for the complete blood counting by comparing conventional counterparts of hematology analyzers (e.g., DxH 900 of Beckman Coulter, XN-1000 of Sysmex, ADVIA 2120i of Siemens, and CELL-DYN Ruby of Abbott) and microfluidic counterparts (e.g., microfluidic impedance and imaging flow cytometry). Future directions of optoelectronic flow cytometry are indicated where intrinsic rather than dependent biophysical parameters of blood cells must be measured, and they can replace blood smears as the gold standard of blood analysis in the near future.


Assuntos
Testes Hematológicos , Microfluídica , Contagem de Células Sanguíneas , Citometria de Fluxo , Testes Hematológicos/métodos , Análise de Célula Única