Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.609
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38969963

RESUMO

BACKGROUND: The clinical impact of Periprocedural myocardial injury (PMI) in patients undergoing permanent pacemaker implantation with Left Bundle Branch Area Pacing (LBBAP) is unknown. METHODS: 130 patients undergoing LBBAP from January 2020 to June 2021 and completing 12 months follow up were enrolled to assess the impact of PMI on composite clinical outcome (CCO) defined as any of the following: all-cause death, hospitalization for heart failure (HHF), hospitalization for acute coronary syndrome (ACS) and ventricular arrhythmias (VAs). High sensitivity Troponin T (HsTnT) was measured up to 24-h after intervention to identify the peak HsTnT values. PMI was defined as increased peak HsTnT values at least > 99th percentile of the upper reference limit (URL: 15 pg/ml) in patients with normal baseline values. RESULTS: PMI occurred in 72 of 130 patients (55%). ROC analysis yielded a post-procedural peak HsTnT cutoff of fourfold the URL for predicting the CCO (AUC: 0.692; p = 0.023; sensitivity 73% and specificity 71%). Of the enrolled patients, 20% (n = 26) had peak HsTnT > fourfold the URL. Patients with peak HsTnT > fourfold the URL exhibited a higher incidence of the CCO than patients with peak HsTnT ≤ fourfold the URL (31% vs. 10%; p = 0.005), driven by more frequent hospitalizations for ACS (15% vs. 3%; p = 0.010). Multiple (> 2) lead repositions attempts, the use of septography and stylet-driven leads were independent predictors of higher risk of PMI with peak HsTnT > fourfold the URL. CONCLUSIONS: PMI seems common among patients undergoing LBBAP and may be associated with an increased risk of clinical outcomes in case of more pronounced (peak HsTnT > fourfold the URL) myocardial damage occurring during the procedure.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38953934

RESUMO

OBJECTIVE: The study aims to investigate the role of dynamic [18F]FDG PET/CT imaging by high-sensitivity PET/CT scanner for assessing patients with locally advanced non-small cell lung cancer (LA-NSCLC) who undergo induction immuno-chemotherapy, followed by concurrent hypo-fractionated chemoradiotherapy (hypo-CCRT) and consolidative immunotherapy. METHODS: Patients with unresectable LA-NSCLC are prospectively recruited. Dynamic [18F]FDG PET/CT scans are conducted at four timepoints: before treatment (Baseline), after induction immuno-chemotherapy (Post-IC), during hypo-CCRT (Mid-hypo-CCRT) and after hypo-CCRT (Post-hypo-CCRT). The primary lung tumors (PTs) are manually delineated, and the metabolic features, including the Patlak-Ki (Ki), maximum SUV (SUVmax), metabolic tumor volume (MTV) and total lesion glycolysis (TLG) have been evaluated. The expressions of CD3, CD8, CD68, CD163, CD34 and Ki67 in primary lung tumors at baseline are assayed by immunohistochemistry. The levels of blood lymphocytes at four timepoints are analyzed with flow cytometry. RESULTS: Fifteen LA-NSCLC patients are enrolled between December 2020 and December 2022. Baseline Ki of primary tumor yields the highest AUC values of 0.722 and 0.796 for predicting disease progression and patient death, respectively. Patients are classified into the High FDG Ki group (n = 8, Ki > 2.779 ml/min/100 g) and the Low FDG Ki group (n = 7, Ki ≤ 2.779 ml/min/100 g). The High FDG Ki group presents better progression-free survival (P = 0.01) and overall survival (P = 0.025). The High FDG Ki group exhibits more significant reductions in Ki after hypo-CCRT compared to the Low FDG Ki group. Patients with a reduction in Ki > 73.1% exhibit better progression-free survival than those with a reduction ≤ 73.1% in Ki (median: not reached vs. 7.33 months, P = 0.12). The levels of CD3+ T cells (P = 0.003), CD8+ T cells (P = 0.002), CD68+ macrophages (P = 0.071) and CD163+ macrophages (P = 0.012) in primary tumor tissues are higher in the High FDG Ki group. The High FDG Ki group has higher CD3+CD8+ lymphocytes in blood at baseline (P = 0.108), post-IC (P = 0.023) and post-hypo-CCRT (P = 0.041) than the Low FDG Ki group. CONCLUSIONS: The metabolic features in the High FDG Ki group significantly decrease during the treatment, particularly after induction immuno-chemotherapy. The Ki value of primary tumor shows significant relationship with the treatment response and survival in LA-NSCLC patients by the combined immuno-chemoradiotherapy regimen. TRIAL REGISTRATION: ClinicalTrials.gov. NCT04654234. Registered 4 December 2020.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38954535

RESUMO

BACKGROUND: Diagnosing myocardial infarction (MI) in patients with chronic kidney disease (CKD) is difficult as they often have increased high-sensitivity cardiac troponin T (hs-cTnT) concentrations. METHODS: Observational U.S. cohort study of emergency department (ED) patients undergoing hs-cTnT measurement. Cases with >1 hs-cTnT increase >99th percentile were adjudicated following the Fourth Universal Definition of MI. Diagnostic performance of baseline and serial 2-hour hs-cTnT thresholds for ruling-in acute MI was compared between those without and with CKD (eGFR <60 ml/min/1.73m2). RESULTS: The study cohort included 1992 patients, amongst whom 501 (25%) had CKD. There were 75 (15%) and 350 (70%) patients with CKD and 80 (5%) and 351 (24%) without CKD who had acute MI and myocardial injury. In CKD patients with baseline hs-cTnT thresholds of >52, >100, >200 or >300 ng/L, PPVs for MI were 36% (95% CI 28-45), 53% (95% CI 39-67), 73% (95% CI 50-89) and 80% (95% CI 44-98), and in those without CKD, 61% (95% CI 47-73), 69% (95% CI 49-85), 59% (95% CI 33-82) and 54% (95% CI 25-81). In CKD patients with a 2-hour hs-cTnT delta of >10, >20 or >30 ng/L, PPVs were 66% (95% CI 51-79), 86% (95% CI 68-96) and 88% (95% CI 68-97), and in those without CKD, 64% (95% CI 50-76), 73% (95% CI 57-86) and 75% (95% CI 58-88). CONCLUSION: Diagnostic performance of standard baseline and serial 2-hour hs-cTnT thresholds to rule-in MI is suboptimal in CKD patients. It significantly improves when using higher baseline thresholds and delta values.

4.
Heliyon ; 10(12): e32784, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38975074

RESUMO

Early diagnosis of HIV-1 is crucial to minimize transmission, morbidity, and mortality, particularly for neonates with developing immune systems. This study aimed to develop and evaluate a simplified, high-sensitivity assay for early HIV-1 detection before seroconversion. The assay utilizes reverse-transcription-polymerase chain reaction (RT-PCR) to amplify the HIV-1 RNA protease gene. Digoxigenin (dig)-labeled forward, and biotin-labeled universal reverse primers are used, generating digoxigenin-amplicon-biotin (DAB) products. These products are detected using a lateral flow assay (LFA) containing a conjugated pad with colloidal gold-labeled 6-histidine tag-fused maltose-binding protein-monomeric streptavidin (6HISMBP-mSA-CGC). Anti-dig monoclonal antibody (mAb) and biotinylated-BSA are immobilized in the test and control line zones, respectively. Five plasma samples with known viral load (VL) were used to simulate the efficacy of early HIV-1 detection. RNA extracted from these samples was amplified by RT-PCR using the labeled primers, and DAB products were examined on agarose gel electrophoresis and LFA. RT-PCR from diluted clinical samples yielded visible DNA bands in agarose gel electrophoresis, consistent with positive LFA results. Conversely, negative samples only displayed the control line on LFA. This assay exhibited a limit of detection (LOD) of 82.29 RNA copies/mL, comparable to other nucleic acid amplification tests (NAATs). This novel technique provides a highly sensitive assay for early HIV-1 diagnosis, even with low VL, making it suitable for resource-limited settings.

5.
Lancet Reg Health Eur ; 43: 100960, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38975590

RESUMO

Background: Guidelines recommend high-sensitivity cardiac troponin to risk stratify patients with possible myocardial infarction and identify those eligible for discharge. Our aim was to evaluate adoption of this approach in practice and to determine whether effectiveness and safety varies by age, sex, ethnicity, or socioeconomic deprivation status. Methods: A multi-centre cohort study was conducted in 13 hospitals across the United Kingdom from November 1st, 2021, to October 31st, 2022. Routinely collected data including high-sensitivity cardiac troponin I or T measurements were linked to outcomes. The primary effectiveness and safety outcomes were the proportion discharged from the Emergency Department, and the proportion dead or with a subsequent myocardial infarction at 30 days, respectively. Patients were stratified using peak troponin concentration as low (<5 ng/L), intermediate (5 ng/L to sex-specific 99th percentile), or high-risk (>sex-specific 99th percentile). Findings: In total 137,881 patients (49% [67,709/137,881] female) were included of whom 60,707 (44%), 42,727 (31%), and 34,447 (25%) were stratified as low-, intermediate- and high-risk, respectively. Overall, 65.8% (39,918/60,707) of low-risk patients were discharged from the Emergency Department, but this varied from 26.8% [2200/8216] to 93.5% [918/982] by site. The safety outcome occurred in 0.5% (277/60,707) and 11.4% (3917/34,447) of patients classified as low- or high-risk, of whom 0.03% (18/60,707) and 1% (304/34,447) had a subsequent myocardial infarction at 30 days, respectively. A similar proportion of male and female patients were discharged (52% [36,838/70,759] versus 54% [36,113/67,109]), but discharge was more likely if patients were <70 years old (61% [58,533/95,227] versus 34% [14,428/42,654]), from areas of low socioeconomic deprivation (48% [6697/14,087] versus 43% [12,090/28,116]) or were black or asian compared to caucasian (62% [5458/8877] and 55% [10,026/18,231] versus 46% [35,138/75,820]). Interpretation: Despite high-sensitivity cardiac troponin correctly identifying half of all patients with possible myocardial infarction as being at low risk, only two-thirds of these patients were discharged. Substantial variation in the discharge of patients by age, ethnicity, socioeconomic deprivation, and site was observed identifying important opportunities to improve care. Funding: UK Research and Innovation.

6.
Adv Sci (Weinh) ; : e2403779, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38978349

RESUMO

Only microstructures are used to improve the sensitivity of iontronic pressure sensors. By modulating the compressive modulus, a breakthrough in the sensitivity of the iontronic pressure sensor is achieved. Furthermore, it allows for programmatic tailoring of sensor performance according to the requirements of different applications. Such a new strategy pushes the sensitivity up to a record-high of 25 548.24 kPa-1 and expands the linear pressure range from 15 to 127 kPa. Additionally, the sensor demonstrates excellent mechanical stability over 10 000 compression-release cycles. Based on this, a well-controlled robotic hand that precisely tracks the pressure behavior inside a balloon to autonomously regulate the gripping angle is developed. This paves the way for the application of iontronic pressure sensors in precise sensing scenarios.

7.
Transl Pediatr ; 13(6): 908-920, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38984031

RESUMO

Background: Troponin (Tn) is of an important biomarker for the diagnosis and prognosis of myocardial injury and for evaluating the severity of cardiac involvement due to other systemic diseases in children. Unfortunately, high-sensitivity cardiac troponin I (hs-cTnI) specific reference intervals (RIs) are extremely limited. This study aimed to establish a preliminary pediatric hs-cTnI RI for newborns, children, and adolescents in Wuhan, China. Methods: A total of 1,355 healthy participants (1 day to 19 years) were recruited from a cross-sectional study implemented in Wuhan Children's Hospital from September 2022 to August 2023. Serum hs-cTnI levels were detected via the Mindray automated chemiluminescence immunoassay analyzer (CL-6000i). Specific serum hs-cTnI RIs were established according to the Clinical and Laboratory Standards Institute (CLSI) guidelines. The RIs were defined by the nonparametric median (P50), and 2.5th, 97.5th [P50 (P2.5-P97.5)] intervals. Results: Of the 1,355 pediatric participants, serum hs-cTnI concentrations of 1,332 children were measured. The serum overall P50 and 95% interval range (P2.5-P97.5) of serum hs-cTnI was 0.41 (0.00, 44.31) ng/L. This was higher in males of 0.47 (0.00, 44.90) ng/L than in females of 0.36 (0.00, 44.17) ng/L (P<0.01). Age- and sex-specific differences in hs-cTnI levels were observed. The levels were highly variable in children under 1 year of age (especially in newborns), deriving a P50 (P2.5-P97.5) of 22.06 (1.04, 154.22) ng/L, and gradually narrowed and decreased with increasing age, with a markedly lower established P50 (P2.5-P97.5) of 0.36 (0.00, 2.16) ng/L. However, the levels began to increase slightly at the age of 9-12 years and reached a small peak at the age range of 15 to 18 years in males with 0.71 (0.03, 3.29) ng/L, while females were less affected by puberty. Sex- and age-specific RIs for hs-cTnI were established: 5 age-specific RIs in males, 1 day-1 month: 30.16 (8.67, 171.81) ng/L; >1-12 months: 13.20 (0.63, 61.91) ng/L; >1-15 years: 0.36 (0.00, 1.86) ng/L; >15-18 years: 0.71 (0.03, 3.29) ng/L; >18-19 years: 0.52 (0.00, 1.92) ng/L; and 4 age-specific RIs in females, 1 day-1 month: 43.93 (18.82, 146.38) ng/L; >1-12 months: 5.22 (0.92, 42.54) ng/L; >1-6 years: 0.54 (0.00, 2.74) ng/L; >6-19 years: 0.23 (0.00, 1.56) ng/L. Conclusions: This study preliminarily established age- and sex-specific serum hs-cTnI RIs using the Mindray CL-6000i system in healthy children in Wuhan, China.

8.
J Clin Med ; 13(12)2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38930061

RESUMO

Background: Cardiac troponin release is related to the cardiomyocyte loss occurring in heart failure (HF). The prognostic role of high-sensitivity cardiac troponin T (hs-cTnT) in several settings of HF is under investigation. The aim of the study is to assess the prognostic role of intrahospital hs-cTnT in patients admitted due to HF. Methods: In this observational, single center, prospective study, patients hospitalized due to HF have been enrolled. Admission, in-hospital peak, and discharge hs-cTnT have been assessed. Patients were followed up for 6 months. Cardiovascular (CV) death, HF hospitalization (HFH), and worsening HF (WHF) (i.e., urgent ambulatory visit/loop diuretics escalation) events have been assessed at 6-month follow up. Results: 253 consecutive patients have been enrolled in the study. The hs-cTnT median values at admission and discharge were 0.031 ng/mL (IQR 0.02-0.078) and 0.031 ng/mL (IQR 0.02-0.077), respectively. The risk of CV death/HFH was higher in patients with admission hs-cTnT values above the median (p = 0.02) and in patients who had an increase in hs-cTnT during hospitalization (p = 0.03). Multivariate Cox regression analysis confirmed that hs-cTnT above the median (OR: 2.06; 95% CI: 1.02-4.1; p = 0.04) and increase in hs-cTnT during hospitalization (OR:1.95; 95%CI: 1.006-3.769; p = 0.04) were predictors of CV death/HFH. In a subgroup analysis of patients with chronic HF, hs-cTnT above the median was associated with increased risk of CV death/HFH (p = 0.03), while in the subgroup of patients with HFmrEF/HFpEF, hs-cTnT above the median was associated with outpatient WHF events (p = 0.03). Conclusions: Inpatient hs-cTnT levels predict CV death/HFH in patients with HF. In particular, in the subgroup of chronic HF patients, hs-cTnT is predictive of CV death/HFH; while in patients with HFmrEF/HFpEF, hs-cTnT predicts WHF events.

9.
Ann Lab Med ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38910539

RESUMO

Cardiac biomarkers, especially high-sensitivity cardiac troponin C or I (hs-cTnC or hs-cTnI, respectively), are vital for diagnosing acute myocardial infarction (AMI). Despite the specificity of hs-cTn as a biomarker, the creatine kinase-myocardial band (CK-MB) is commonly used alongside hs-cTn in emergency departments (EDs). We analyzed 23,771 simultaneous hs-cTn (hs-cTnT or hs-cTnI) and CK-MB requests for 17,185 patients in tertiary hospital ED in 2022. The objective of this study was to assess their practical value in diagnosing AMI in real-world settings. Among all 17,185 patients tested, 98.0% underwent hs-cTnT and CK-MB tests, and substantially fewer underwent hs-cTnI testing. We observed concordance between the initial hs-cTn and CK-MB results in 71.3% of patients. Of 131 AMI cases, 57 were positive for both biomarkers, 63 for hs-cTn only, and none for CK-MB alone. CK-MB positivity was often found in the absence of AMI. Discrepancies between the hs-cTnT and hs-cTnI results occurred in 30.0% of patients. Indiscriminate CK-MB testing for diagnosing AMI in EDs should be reconsidered. Efficient use of CK-MB is important for reducing costs and ensuring optimal patient care.

11.
Biosensors (Basel) ; 14(6)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38920585

RESUMO

Oral cancer represents a significant global public health challenge, contributing substantially to the incidence and mortality of cancer. Despite established risk factors such as tobacco use and alcohol consumption, early detection remains crucial for effective treatment. This study introduces a novel approach using a transistor-based biosensor system for detecting the P90 (CIP2A) protein. We tested the presence of CIP2A in human leukoplakia samples, which can undergo malignant conversion into aggressive oral squamous cell carcinoma. The method used commercially available glucose test strips functionalized with P90 antibodies, providing high sensitivity and a low limit of detection which was five orders lower than that of commercial ELISA kits. A specially designed printed circuit board (PCB) facilitated accurate measurements, and the device's performance was optimized through characteristic tests. Human sample testing validated the biosensor's effectiveness in distinguishing samples after cell lysis. This study contributes to advancing accurate and cost-effective diagnostic approaches for oral pre-cancer and cancer tissues.


Assuntos
Técnicas Biossensoriais , Leucoplasia Oral , Saliva , Humanos , Leucoplasia Oral/diagnóstico , Saliva/química , Biomarcadores Tumorais/análise , Proteínas de Membrana , Neoplasias Bucais/diagnóstico , Ensaio de Imunoadsorção Enzimática
12.
Food Chem ; 455: 139850, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38850984

RESUMO

Direct, rapid and highly sensitive detection of heavy metals in rice is essential to ensure food safety. In this research, a combination of laser ablation and microwave plasma torch optical emission spectrometry (LA-MPT-OES) was proposed. Based on the optimal observation positions, a high sensitivity and direct determination of Cd, Hg, Pb and Cr in rice were realized. The limits of detection (LOD) were 0.97, 0.12, 0.61 and 0.15 µg/kg, respectively, which were reduced by one order of magnitude compared to the optimal observation height. In addition, the LOD was reduced by one to two orders of magnitude compared with the techniques that require sample pre-treatment. Moreover, the results of the Certified Reference Materials and real samples were in agreement with the reference values with a relative error in the range of 0.28% âˆ¼ 14.16%. The results demonstrated that LA-MPT-OES could be a promising tool to detect heavy metals in rice.


Assuntos
Cádmio , Contaminação de Alimentos , Chumbo , Mercúrio , Metais Pesados , Oryza , Oryza/química , Contaminação de Alimentos/análise , Metais Pesados/análise , Chumbo/análise , Cádmio/análise , Mercúrio/análise , Limite de Detecção , Análise Espectral/métodos , Micro-Ondas
13.
Int J Mol Sci ; 25(12)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38928420

RESUMO

Self-powered wearable pressure sensors based on flexible electronics have emerged as a new trend due to the increasing demand for intelligent and portable devices. Improvements in pressure-sensing performance, including in the output voltage, sensitivity and response time, can greatly expand their related applications; however, this remains challenging. Here, we report on a highly sensitive piezoelectric sensor with novel light-boosting pressure-sensing performance, based on a composite membrane of copper phthalocyanine (CuPC) and graphene oxide (GO) (CuPC@GO). Under light illumination, the CuPC@GO piezoelectric sensor demonstrates a remarkable increase in output voltage (381.17 mV, 50 kPa) and sensitivity (116.80 mV/kPa, <5 kPa), which are approximately twice and three times of that the sensor without light illumination, respectively. Furthermore, light exposure significantly improves the response speed of the sensor with a response time of 38.04 µs and recovery time of 58.48 µs, while maintaining excellent mechanical stability even after 2000 cycles. Density functional theory calculations reveal that increased electron transfer from graphene to CuPC can occur when the CuPC is in the excited state, which indicates that the light illumination promotes the electron excitation of CuPC, and thus brings about the high polarization of the sensor. Importantly, these sensors exhibit universal spatial non-contact adjustability, highlighting their versatility and applicability in various settings.


Assuntos
Grafite , Indóis , Luz , Compostos Organometálicos , Grafite/química , Indóis/química , Compostos Organometálicos/química , Dispositivos Eletrônicos Vestíveis
14.
ACS Appl Mater Interfaces ; 16(27): 35771-35780, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38935816

RESUMO

Flexible surface-enhanced Raman scattering (SERS) substrates are very promising to meet the needs for real-time and on-field detection in practical applications. However, high-performance flexible SERS substrates often suffer from complexity and high cost in fabrication, limiting their widespread applications. Herein, we developed a facile method to fabricate a flexible multicavity SERS substrate composed of a silver nanoparticle (AgNP)-decorated aluminum hydrous oxide nanoflake array (NFA) grown on a polydimethylsiloxane (PDMS) membrane. Strong plasmon couplings promoted by multiple nanocavities afford high-density hotspots within such a flexible AgNPs@NFA/PDMS film, boosting high SERS sensitivity with an enhancement factor (EF) of ∼1.54 × 109, and a limit of detection (LOD) of ∼7.4 × 10-13 M for rhodamine 6G (R6G) molecules. Furthermore, benefiting from the high sensitivity, high mechanical stability, and transparency of this substrate, in situ SERS detections of trace thiram and crystal violet (CV) molecules on the surface of cherry tomatoes and fish have been realized, with LODs much lower than the maximum allowable limit in food, demonstrating the great potential of such a flexible substrate in food safety monitoring. More importantly, the preparation processes are very simple and environmentally friendly, and the techniques involved are completely compatible with well-established silicon device technologies. Therefore, large-area fabrication with low cost can be readily realized, enabling the extensive applications of SERS sensors in daily life.

15.
J Am Heart Assoc ; 13(13): e034549, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38842289

RESUMO

BACKGROUND: High-sensitivity troponin I (hs-cTnI) and T (hs-cTnT) provide complementary information regarding cardiovascular disease risk. The explanation for their distinct risk profiles is incompletely understood. METHODS AND RESULTS: hs-cTnI and hs-cTnT were measured in Dallas Heart Study participants. Associations of hs-cTnI and hs-cTnT with demographics and phenotypes were assessed using linear regression. Associations with incident heart failure, atherosclerotic cardiovascular disease, global cardiovascular disease, and cardiovascular and all-cause mortality were assessed using Cox models. Among 3276 participants (56% women, 50% Black persons, median age 43 years), the correlation between hs-cTnI and hs-cTnT was modest (Spearman rho=0.35). Variables associated with hs-cTnI but not hs-cTnT included hypertension, higher body mass index and total cholesterol, and lower high-density lipoprotein and cholesterol efflux capacity. Older age, male sex, and diabetes were positively associated, and smoking was negatively associated, with hs-cTnT but not hs-cTnI. Hs-cTnI and hs-cTnT were associated with heart failure (hazard ratio [HR] per SD log hs-cTnI 1.53 [95% CI, 1.30-1.81] and HR per SD log hs-cTnT 1.65 [95% CI, 1.40-1.95]), global cardiovascular disease (HR, 1.22 [95% CI, 1.10-1.34] and HR, 1.27 [95% CI, 1.15-1.32]), and all-cause mortality (HR, 1.12 [95% CI, 1.01-1.25], and HR, 1.17 [95% CI, 1.06-1.29]). After adjustment for N-terminal pro-B-type natriuretic peptide and the alternative troponin, both remained associated with heart failure (HR per SD log hs-cTnI 1.32 [95% CI, 1.1-1.58] and HR per log hs-cTnT 1.27 [95% CI, 1.06-1.51]). CONCLUSIONS: Hs-cTnI and hs-cTnT are modestly correlated, demonstrate differential associations with cardiac and metabolic phenotypes, and provide complementary information regarding heart failure risk.


Assuntos
Biomarcadores , Fenótipo , Troponina I , Troponina T , Humanos , Feminino , Masculino , Troponina I/sangue , Troponina T/sangue , Pessoa de Meia-Idade , Adulto , Biomarcadores/sangue , Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/diagnóstico , Texas/epidemiologia , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/diagnóstico , Medição de Risco/métodos , Prognóstico , Incidência , Fatores de Risco , Valor Preditivo dos Testes
16.
Adv Mater ; : e2407138, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38887139

RESUMO

MXene aerogels, known for good electrical properties, offer immense potential for the development of high-sensitivity pressure sensors. However, the intrinsic challenges stemming from the poor self-assembly capability and high hydrophilicity of MXene impedes the natural drying process of MXene-based hydrogels, thereby constraining their application on a large-sacle in sensor technology. Herein, we propose a graphene-assisted approach aimed at modulating the hydrophobicity and enhancing framework strength of MXene through a well-designed prefreezing technique incorporating three-dimensional (3D) spherical macro-porous structures. This synergistic strategy enables the fabrication of naturally dried MXene aerogels across various size scales. Moreover, the integration of 3D spherical macro-porous structures improves elasticity and electrical responsiveness of aerogels. Consequently, the aerogel sensor exhibits great performances, including high sensitivity (1250 KPa-1), low detection limit (0.4 Pa), wide frequency response range (0.1-8 Hz), and excellent stability (1000 cycles). This sensor proves adept at monitoring pressure signals ranging from lightweight paper to human motion. Additionally, the application of customized laser engraving endows aerogels with unique functionalities, such as compressibility and immunity to strain, stretchability and resistance to compression, as well as wind detection. Thus, our proposed approach holds significant promise as a scalable method for the mass production of aerogels with versatile applications. This article is protected by copyright. All rights reserved.

17.
Materials (Basel) ; 17(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38893757

RESUMO

With the arrival of the Internet of Things era, the demand for tactile sensors continues to grow. However, traditional sensors mostly require an external power supply to meet real-time monitoring, which brings many drawbacks such as short service life, environmental pollution, and difficulty in replacement, which greatly limits their practical applications. Therefore, the development of a passive self-power supply of tactile sensors has become a research hotspot in academia and the industry. In this review, the development of self-powered tactile sensors in the past several years is introduced and discussed. First, the sensing principle of self-powered tactile sensors is introduced. After that, the main performance parameters of the tactile sensors are briefly discussed. Finally, the potential application prospects of the tactile sensors are discussed in detail.

18.
Bioinformation ; 20(4): 378-385, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38854770

RESUMO

The association between serum interleukin-6 (IL-6) and highly sensitive C - reactive protein (hsCRP) as predictors of the risk factors for Myocardial Infarction. The study included a total of 50 patients with Myocardial Infarction, aged between 25 to 74 years. The levels of hsCRP were measured using the immunoturbidimetry method, while Interleukin 6 was estimated using the sandwich ELISA method. Statistical analysis was conducted using SPSS version 21.0, with p values calculated using Quartile ratio, ANOVA unpaired t-test, and Kaplan-Meier Curve Method. A p-value of less than 0.05 was considered statistically significant. All participants underwent a questionnaire, physical examination, medical history assessment, and laboratory tests. The results of the study showed that there was a significant correlation between IL-6 and hsCRP levels in the Quartile groups, as well as with lipid profiles. The Kaplan-Meier method also demonstrated a significant association between IL-6 and hsCRP levels in participants. The comparison of biomarkers further supported these findings. Thus, data shows that elevated levels of hsCRP and IL-6 could serve as valuable diagnostic markers for predicting Acute Myocardial Infarction. Our study strongly suggests that IL-6 could be a powerful marker in evaluating the Myocardial Infarction.

19.
Acta Cardiol ; : 1-6, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884420

RESUMO

BACKGROUND: Impaired glucose tolerance (IGT) and impaired fasting glucose (IFG) are an increasingly serious problem worldwide. Tissue Doppler imaging (TDI), a non-invasive technique, may evaluate both systolic and diastolic function during the first phases of cardiovascular disease (CVD). High-sensitivity cardiac troponin T (hs-cTnT) can detect subclinical myocardial injury in asymptomatic prediabetic patients. AIM: We aimed to investigate the relationship between left ventricular (LV) function and hs-cTnT in prediabetic patients. METHODS: Between 1 October 2021 and 1 October 2022, we recruited 96 prediabetic and an equal number of age- and gender-matched healthy volunteers prospectively. TDI was used to evaluate both systolic and diastolic functions. Hs-cTnT levels were obtained and compared between groups. RESULTS: It was found that the values for mitral annular plane systolic excursion (MAPSE), E, the rapid filling wave, E/Em, and the peak annular velocities of systolic excursion in the ejection period (Sm) were all significantly higher in these patients compared to healthy individuals (p < .001). Hs-cTnT was an independent predictor of left ventricular diastolic dysfunction (LVDD) and left ventricular systolic dysfunction (LVSD) (odds ratio [OR] = 2.625, 95% confidence interval [CI] = 1.324-4.308, p < .001, and OR = 1.922, 95% CI = 0.454-3.206, p = .004). CONCLUSIONS: Prediabetics had higher hs-cTnT levels than controls. We showed that LVSD and LVDD functions were negatively affected in prediabetic patients. Our results proved that hs-cTnT levels may be associated with subclinical LV dysfunction in prediabetes.

20.
Nano Lett ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38842083

RESUMO

The primary challenge for resonant-gravimetric gas sensors is the synchronous improvement of the sensitivity and response time, which is restricted by low adsorption capacity and slow mass transfer in the sensing process and remains a great challenge. In this study, a novel 2D/2D Cu-TCPP@ZnIn2S4 composite is successfully constructed, in which Cu-TCPP MOF is used as a core substrate for the growth of 2D ultrathin ZnIn2S4 nanosheets with well-defined {0001} crystalline facets. The Cu-TCPP@ZnIn2S4 sensor exhibited high sensitivity (1.5 Hz@50 and 2.3 Hz@100 ppb), limit of detection (LOD: 50 ppb), and ultrafast (9 s @500 ppb) detection of triethylamine (TEA), which is the lowest LOD and the fastest sensor among the reported TEA sensors at room temperature, tackling the bottleneck for the ultrafast detection of the resonant-gravimetric sensor. These above results provide an innovative and easily achievable pathway for the synthesis of heterogeneous structure sensing materials.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...