Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Front Surg ; 11: 1386722, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38933651

RESUMO

Introduction: Infrared thermography (IT) is a non-invasive real-time imaging technique with potential application in different areas of neurosurgery. Despite technological advances in the field, intraoperative IT (IIT) has been an underestimated tool with scarce reports on its usefulness during intracranial tumor resection. We aimed to evaluate the usefulness of high-resolution IIT with static and dynamic thermographic maps for transdural lesion localization, and diagnosis, to assess the extent of resection, and the occurrence of perioperative acute ischemia. Methods: In a prospective study, 15 patients affected by intracranial tumors (six gliomas, four meningiomas, and five brain metastases) were examined with a high-resolution thermographic camera after craniotomy, after dural opening, and at the end of tumor resection. Results: Tumors were transdurally located with 93.3% sensitivity and 100% specificity (p < 0.00001), as well as cortical arteries and veins. Gliomas were consistently hypothermic, while metastases and meningiomas exhibited highly variable thermographic maps on static (p = 0.055) and dynamic (p = 0.015) imaging. Residual tumors revealed non-specific static but characteristic dynamic thermographic maps. Ischemic injuries were significantly hypothermic (p < 0.001). Conclusions: High-resolution IIT is a non-invasive alternative intraoperative imaging method for lesion localization, diagnosis, assessing the extent of tumor resection, and identifying acute ischemia changes with static and dynamic thermographic maps.

2.
Belo Horizonte; s.n; 2024. 46 p. ilus.
Tese em Português | BBO - Odontologia | ID: biblio-1566493

RESUMO

A cirurgia guiada representa um avanço significativo na Odontologia moderna, especialmente na implantodontia, onde a precisão e previsibilidade são fundamentais para o sucesso dos procedimentos. Os passos dentro da sequência de fluxo de trabalho digital para cirurgia guiada são: aquisição de dados volumétricos, procedimentos de escaneamento de superfície via escaneamento intraoral ou escaneamento de modelo extraoral, software de planejamento computacional, design e manufatura de guias cirúrgicos via impressão 3D. A cirurgia guiada está cada vez mais rotineira na Odontologia contemporânea, demonstrando como a integração de tecnologias digitais pode transformar significativamente a prática clínica, elevando os padrões de precisão, previsibilidade e qualidade dos resultados em implantodontia. Além disso, esta técnica permite uma abordagem personalizada para cada caso clínico, adaptando-se às particularidades anatômicas e às necessidades específicas do paciente. O objetivo do estudo foi estabelecer um protocolo um protocolo completo para o planejamento e execução de implantes guiados, com as tecnologias e recursos disponíveis na Faculdade de Odontologia da UFMG.


Guided surgery represents a significant advancement in modern dentistry, particularly in implantology, where precision and predictability are crucial for procedural success. The steps within the digital workflow sequence for guided surgery include: volumetric data acquisition, surface scanning procedures via intraoral scanning or extraoral model scanning, computational planning software, and design and manufacture of surgical guides via 3D printing. Guided surgery is increasingly becoming routine in contemporary dentistry, showcasing how the integration of digital technologies can substantially transform clinical practice by enhancing standards of precision, predictability, and quality of outcomes in implantology. Moreover, this technique allows for a personalized approach to each clinical case, adapting to anatomical particularities and specific patient needs. The aim of this study was to establish a comprehensive protocol for the planning and execution of guided implants, utilizing the technologies and resources available at the Faculty of Dentistry of UFMG.


Assuntos
Cirurgia Bucal , Desenho Assistido por Computador , Cirurgia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico , Impressão Tridimensional
3.
Cancers (Basel) ; 15(7)2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-37046740

RESUMO

BACKGROUND: Head and neck squamous cell carcinoma (HNSCC) is the sixth most common cancer affecting people and accounts for more than 300,000 deaths worldwide. Improvements in treatment modalities, including immunotherapy, have demonstrated promising prognoses for eligible patients. Nevertheless, the five-year overall survival rate has not increased significantly, and the tumor recurrence ratio remains at 50% or higher, except for patients with HPV-positive HNSCC. Over the last decades, nanotechnology has provided promising tools, especially for biomedical applications, due to some remarkable physicochemical properties of numerous nanomaterials, particularly gold nanoparticles. This review addresses the features and some applications of gold nanoparticles reported in the literature over the last five years regarding the diagnosis and treatment of head and neck cancer, highlighting the exciting possibilities of this nanomaterial in oncology. METHODS: The scientific papers selected for this review were obtained from the PubMed Advanced, Web of Science, Scopus, ClinicalTrials.gov, and Google Scholar platforms. CONCLUSIONS: Results from papers applying gold nanoparticles have suggested that their application is a feasible approach to diagnostics, prognostics, and the treatment of HNC. Moreover, phase I clinical trials suggest that gold nanoparticles are safe and can potentially become theranostic agents for humans.

4.
Arq. bras. neurocir ; 42(4): 269-276, 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1570902

RESUMO

Objective Intraoperative ultrasound (IOUS) is an imaging method that can be used in various neurosurgical procedures. It assists in the removal of brain tumors, hematomas, in the insertion of ventricular catheters, and in spinal and peripheral nerve surgeries. The original studies using IOUS were performed with devices that produced lower-quality images, generating little interest in their use. The introduction of ultrasound devices that yielded higher-quality images associated with a relative low cost and ease of use rendered IOUS attractive. Thus, we started using it in multiple neurosurgical procedures, studying its practicality, efficacy and limitations. Materials and methods A retrospective case study on the use of IOUS in neurosurgery from August 2014 to December 2020 at a single institution, evaluating its practicality, efficacy and limitations. Results A total of 127 IOUS scans were performed in 112 patients aged 19 to 83 (mean: 53.8) years: 106 scans of the brain, 4 of the spinal cord, and 2 of the peripheral nerves. Brain tumors were the majority, with 86 cases (67.8%). The IOUS was unsatisfactory in 9 cases (7.1%), and there were no cases of infection related to the IOUS. Conclusion The IOUS is a dynamic, safe, and practical exam. It can be performed in a few minutes and repeated several times during the surgical procedure. It enables surgeons to observe the pulsation of tissues and vessels, the displacement of lumps in liquid collections, and to monitor the drainage of cysts and collections, in vivid, interactive and real-time images.


Objetivo A ultrassonografia intraoperatória (USIO) é um método de imagem que pode ser utilizado em vários procedimentos neurocirúrgicos. Auxilia na remoção de tumores cerebrais, hematomas, no implante de cateteres ventriculares, e em cirurgias espinhais e de nervos periféricos. Os estudos iniciais com a USIO eram realizados com aparelhos que disponibilizavam imagens de baixa qualidade, o que gerava pouco interesse no seu uso. Com o desenvolvimento de aparelhos de ultrassom que produziam imagens de melhor qualidade, eram de fácil manuseio e tinham relativo baixo custo, reacendeu-se o interesse na USIO. Por este motivo, iniciamos a utilização da USIO em múltiplos procedimentos neurocirúrgicos, e estudamos sua praticidade, eficácia e limitações. Materiais e métodos Estudo retrospectivo dos casos em que a USIO foi utilizada em neurocirurgia de agosto de 2014 a dezembro de 2020 em uma só instituição, com a avaliação de sua praticidade, eficácia e limitações. Resultados Foram realizadas 127 USIOs em 112 pacientes com idades entre 19 e 83 (média: 53,8) anos, 106 no encéfalo, 4 em medula espinhal, e 2 em nervo periférico. Os tumores cerebrais foram a maioria, com 86 casos (67,8%). A USIO foi insatisfatória em 9 casos (7,1%), e não houve casos de infecção relacionada à USIO. Conclusões A USIO é um exame dinâmico, seguro e prático. Pode ser feito em poucos minutos e repetido várias vezes durante o procedimento cirúrgico. É possível observar a pulsação dos tecidos e vasos, o deslocamento de grumos em coleções líquidas, e acompanhar a drenagem de cistos e coleções, em imagens vivas, interativas e em tempo real.

5.
Acta Ortop Bras ; 30(spe1): e248982, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35864829

RESUMO

Objective: To evaluate the effect of 3d printed models on surgical pre-operative planning of complex spinal deformities. Methods: In our study, five orthopedic surgeons made surgical planning of 5 patients with severe spinal deformity in three conditions: X-ray with computer tomography (X-ray-CT), 3D-computed tomography (3dCT), and 3d printed spine models. Operation plans were examined according to the level and number of instrumentations, osteotomy level, and time required for decision-making. Results: X-ray-CT, 3dCT, and 3d modeling methods were compared, and no statistically significant difference was observed in the number of screws and osteotomy score to be used in operation. The time required for decision ranking is 3d Model, 3d CT, and Xray-CT. Conclusions: 3d printed models do not influence the operative plan significantly; however, it reduces surgical planning time at pre-op duration, and those models gave some opportunities to practice with implants on a patient's 3d spine model. Level of Evidence III; Diagnostic Studies - Investigating a Diagnostic Test .


Objetivo: Avaliar o efeito de modelos 3D impressos no planejamento pré-operatório cirúrgico de deformidades complexas da coluna vertebral. Métodos: Em nosso estudo, 5 cirurgiões ortopédicos fizeram o planejamento cirúrgico de 5 pacientes com deformidade espinhal grave em três condições: raio-X com tomografia computadorizada (raio X-CT), tomografia computadorizada com reconstrução 3D (3dCT) e modelo de coluna vertebral impressa (modelo 3d). Os planos de operação foram examinados de acordo com o nível e número de instrumentos, nível de osteotomia e tempo necessário para a tomada de decisão. Resultados: Foram comparados os métodos de modelagem de raio X-CT, 3dCT e modelo 3d e nenhuma diferença estatisticamente significativa foi observada no número de parafusos e escore de osteotomia a serem utilizados na operação. O ranking do tempo necessário para a tomada de decisão foi de modelo 3d, 3d CT e raio X-CT. Conclusões: Os modelos impressos em 3d não influenciam significativamente o plano operatório, porém reduzem o tempo de planejamento cirúrgico no pré-operatório e esses modelos deram algumas oportunidades de praticar com implantes no modelo de coluna 3d do paciente. Nível de evidência III; Estudos de Diagnóstico - Investigando um Teste de Diagnóstico .

6.
Cardiovasc Intervent Radiol ; 45(3): 330-336, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34796374

RESUMO

PURPOSE: The aim of this study was to report the long-term results of an institutional protocol of percutaneous biliary balloon dilatation (PBBD) on paediatric patients with benign anastomotic stricture after liver transplantation. As a secondary objective, we evaluated risk factors associated with post-treatment re-stricture. MATERIALS AND METHODS: Fourteen paediatric, post-liver transplant patients with benign anastomotic stricture of Roux-en-Y hepaticojejunostomy were included. All patients underwent the same treatment protocol of three PBBD procedures with 15-day intervals. Clinical outcome was analysed using the Terblanche classification. Primary patency rate was assessed with the Kaplan-Meier test. RESULTS: All patients had an initial successful result (Terblanche grade, excellent/good) after PBBD. At the end of the follow-up time of 35.7 ± 21.1 months (CI95%, 23.5-47.9), 10 patients persisted with excellent/good grading, while the remaining 4 had re-stricture, all of the latter occurring within the first 19 months. Patency rate after percutaneous treatment at 1, 3, and 5 years were 85.7%, 70%, and 70%, respectively. History of major complication after liver transplantation was associated with 5 times higher risk of re-stricture, HR 5.48 [95% CI, 2.18-8.78], p = 0.018. CONCLUSION: In paediatric patients with benign anastomotic stricture of hepaticojejunostomy after liver transplantation, the "Three-session" percutaneous biliary balloon dilatation protocol is associated with a high rate of long-term success. In this limited series, the history of post-liver transplant major complication, defined as complications requiring a reintervention under general anaesthesia or advanced life support, seems to be an independent risk factor for stricture recurrence.


Assuntos
Transplante de Fígado , Criança , Constrição Patológica/cirurgia , Dilatação/métodos , Humanos , Transplante de Fígado/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Resultado do Tratamento
7.
Acta ortop. bras ; Acta ortop. bras;30(spe1): e248982, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1383439

RESUMO

ABSTRACT Objective: To evaluate the effect of 3d printed models on surgical pre-operative planning of complex spinal deformities. Methods: In our study, five orthopedic surgeons made surgical planning of 5 patients with severe spinal deformity in three conditions: X-ray with computer tomography (X-ray-CT), 3D-computed tomography (3dCT), and 3d printed spine models. Operation plans were examined according to the level and number of instrumentations, osteotomy level, and time required for decision-making. Results: X-ray-CT, 3dCT, and 3d modeling methods were compared, and no statistically significant difference was observed in the number of screws and osteotomy score to be used in operation. The time required for decision ranking is 3d Model, 3d CT, and Xray-CT. Conclusions: 3d printed models do not influence the operative plan significantly; however, it reduces surgical planning time at pre-op duration, and those models gave some opportunities to practice with implants on a patient's 3d spine model. Level of Evidence III; Diagnostic Studies - Investigating a Diagnostic Test .


RESUMO Objetivo: Avaliar o efeito de modelos 3D impressos no planejamento pré-operatório cirúrgico de deformidades complexas da coluna vertebral. Métodos: Em nosso estudo, 5 cirurgiões ortopédicos fizeram o planejamento cirúrgico de 5 pacientes com deformidade espinhal grave em três condições: raio-X com tomografia computadorizada (raio X-CT), tomografia computadorizada com reconstrução 3D (3dCT) e modelo de coluna vertebral impressa (modelo 3d). Os planos de operação foram examinados de acordo com o nível e número de instrumentos, nível de osteotomia e tempo necessário para a tomada de decisão. Resultados: Foram comparados os métodos de modelagem de raio X-CT, 3dCT e modelo 3d e nenhuma diferença estatisticamente significativa foi observada no número de parafusos e escore de osteotomia a serem utilizados na operação. O ranking do tempo necessário para a tomada de decisão foi de modelo 3d, 3d CT e raio X-CT. Conclusões: Os modelos impressos em 3d não influenciam significativamente o plano operatório, porém reduzem o tempo de planejamento cirúrgico no pré-operatório e esses modelos deram algumas oportunidades de praticar com implantes no modelo de coluna 3d do paciente. Nível de evidência III; Estudos de Diagnóstico - Investigando um Teste de Diagnóstico .

8.
Cardiovasc Intervent Radiol ; 44(10): 1618-1624, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33948696

RESUMO

PURPOSE: The aim of this study was to determine the effect of hyperbilirubinemia in the sensitivity of percutaneous transluminal forceps biopsy (PTFB) in patients with suspected malignant biliary stricture. MATERIALS AND METHODS: Ninety-three patients with suspicion of malignant biliary stricture underwent percutaneous transhepatic cholangiography followed by PTFB. Sensitivity, specificity and predictive values were analysed based on the presence or absence of hyperbilirubinemia, defined as total bilirubin equal to, or higher than 5 mg/dL. Variables included demographic and clinical features, laboratory, tumour type and localization, stricture length, therapeutic approach and histopathology. Additionally, major morbidity and mortality were assessed. RESULTS: The overall sensitivity, specificity, positive predictive value and accuracy of PTFB were 61.1%, 100%, 100%, and 62.4%, respectively. Hyperbilirubinemia affected 57% of patients at the time of PTFB. There were 35 (37%) false negative results, none of them related to tumour type or localization, stricture length, or previous biliary intervention (i.e. PBBD (percutaneous biliary balloon dilatation), ERCP (endoscopic retrograde cholangiopancreatography)) (p > 0.05). However, when bilirubin was < 5 mg/dL, false negative results decreased globally (p = 0.024) and sensitivity increased significantly for intrahepatic and hilar localization, as well as for colorectal metastasis, gallbladder carcinoma, and pancreatic carcinoma. No major morbidity occurred. CONCLUSION: The sensitivity of percutaneous transluminal biopsy for diagnosis of malignant stricture may significantly increase if samples are obtained in the absence of hyperbilirubinemia, without adding morbidity to the procedure. LEVEL OF EVIDENCE: Level 3, Case- Control studies.


Assuntos
Neoplasias dos Ductos Biliares , Colestase , Neoplasias dos Ductos Biliares/complicações , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Neoplasias dos Ductos Biliares/terapia , Biópsia , Colangiopancreatografia Retrógrada Endoscópica , Colestase/diagnóstico por imagem , Colestase/etiologia , Colestase/terapia , Constrição Patológica , Humanos , Sensibilidade e Especificidade , Instrumentos Cirúrgicos
9.
Oper Neurosurg (Hagerstown) ; 20(5): E346-E347, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33855454

RESUMO

Surgical resection is the primary treatment of pilocytic astrocytomas and total removal can be curative. However, these lesions occur in critical areas, such as the thalamus, being surrounded by critical life neurovascular structures, which imposes a surgical challenge.1-5 Exhaustive acquisition and meticulous interpretation of preoperative radiological exams; reliable surgical orientation based on profound microneurosurgical anatomic knowledge and judicious discernment of the neuroanatomic distortions on the surface and deep-seated structures inflicted by the neuropathological entity; embracing and comprehensive application of the vast scope of available intraoperative guidance imaging and neurophysiological monitoring; in alliance with the mastered carefully microsurgical technique supported by endoscopic visualization are the keystones to the pursed duet "cure with quality of life" in the treatment of these lesions. We present the case of a 17-yr-old young lady with a progressive motor deficit in her right hemibody for over 2 yr. Her radiological investigation demonstrated a left thalamic lesion displacing the projection fibers (corticospinal tract) within the internal capsule laterally. The patient consented to the surgical procedure. The surgical strategy, intraoperative findings, and microsurgical and endoscopic technique, as well as the postoperative radiological and clinical evaluation are presented. The patient gave her informed consent for the publication of the case.


Assuntos
Astrocitoma , Neoplasias Encefálicas , Astrocitoma/diagnóstico por imagem , Astrocitoma/cirurgia , Neoplasias Encefálicas/cirurgia , Feminino , Humanos , Procedimentos Neurocirúrgicos , Qualidade de Vida , Tálamo/diagnóstico por imagem , Tálamo/cirurgia
10.
Mater Today Bio ; 10: 100087, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33889836

RESUMO

Fluorescence imaging in the near-infrared II (NIR-II, 1000-1700 nm) region opens up new avenues for biological systems due to suppressed scattering and low autofluorescence at longer-wavelength photons. Nonetheless, the development of organic NIR-II fluorophores is still limited mainly due to the shortage of efficient molecular design strategy. Herein, we propose an approach of designing Janus NIR-II fluorophores by introducing electronic donors with distinct properties into one molecule. As a proof-of-concept, fluorescent dye 2 TT-m, oC6B with both twisted and planar electronic donors displayed balanced absorption and emission which were absent in its parent compound. The key design strategy for Janus molecule is that it combines the merits of intense absorption from planar architecture and high fluorescence quantum yield from twisted motif. The resulting 2 TT-m, oC6B nanoparticles exhibit a high molar absorptivity of 1.12 ⨯104 M-1 cm-1 at 808 nm and a NIR-II quantum yield of 3.7%, displaying a typical aggregation-induced emission (AIE) attribute. The highly bright and stable 2 TT-m, oC6B nanoparticles assured NIR-II image-guided cancer surgery to resect submillimeter tumor nodules. The present study may inspire further development of molecular design philosophy for highly bright NIR-II fluorophores for biomedical applications.

11.
Int J Oral Maxillofac Surg ; 50(10): 1383-1385, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33678490

RESUMO

The identification and management of interfering maxillary sinus septa is essential to anticipate and prevent membrane perforation and other complications during sinus grafting. A computer-guided sinus approach based on a new magnetic stackable surgical guide was planned, to transfer the exact position of the septum and optimize the positioning of the lateral access windows. This technique reduces the risk of sinus membrane injury, thereby increasing the safety and efficacy of the procedure.


Assuntos
Levantamento do Assoalho do Seio Maxilar , Humanos , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/cirurgia
12.
J Laparoendosc Adv Surg Tech A ; 31(2): 146-151, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32936031

RESUMO

Background: Obesity treatment requires surgical procedures included in bariatric surgery. Bleeding complications are reported in 1%-4%. Image-guided surgery (IGS) includes minimally invasive procedures that have the advantage of less aggression to the patient, fewer complications, and a quick recovery. Endovascular therapy by interventional radiology (IR) is a minimally invasive image-guided procedure widely used in central, peripheral, and splanchnic vascular pathology. Treatment of postoperative bleeding in bariatric surgery can be aided by image-guided endovascular procedures. Objectives: The aim of this study is to carry out an update on the application of IR in bariatric surgery bleeding complications. Bleeding Complications: General rate of postoperative complications in bariatric surgery is 0%-10%. Postoperative bleeding (1%-4%) can be gastrointestinal (endoscopic treatment) or intra-abdominal (surgical treatment/relaparoscopy). In the case of arterial vascular lesions that cannot be resolved either endoscopically or surgically, the option of endovascular treatment with IR should be considered. Conclusions: Endovascular approach through IR and IGS in bleeding complications after bariatric surgery is presented as a valid minimally invasive therapy option in this group of patients.


Assuntos
Cirurgia Bariátrica/efeitos adversos , Hemorragia/cirurgia , Árvores de Decisões , Procedimentos Endovasculares/efeitos adversos , Humanos , Complicações Pós-Operatórias/cirurgia , Radiologia Intervencionista , Cirurgia Assistida por Computador
13.
J Laparoendosc Adv Surg Tech A ; 31(2): 166-170, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32960138

RESUMO

Background: Bariatric surgery is an effective treatment for obesity and its associated morbidities. They are safe surgeries, their general complication rate is 0%-10%. However, acute gastric dilation is an unusual complication. It requires rapid diagnosis and treatment to avoid major complications. Image-guided surgery represents a group of minimally invasive procedures. Acute gastric dilation is a complication that can benefit from the application of this type of procedure. We present a report of patients with acute gastric dilation of the remnant as a complication after bariatric surgery, its resolution through image-guided surgery, and updating. Materials and Methods: A retrospective review of patients who presented postoperative complications after bariatric surgery was carried out. The time period was 10 years. All patients were operated on in a single center by the same surgical team. Results: A total of 3507 bariatric procedures were analyzed (sleeve gastrectomy, 1929-55.1% ± 0.49%; Roux-en-Y gastric bypass [RYGB], 1403-40% ± 0.48%; other techniques, 175-4.9% ± 0.21%). The RYGB branch reported a total of 11 (0.78% ± 0.08%) complications, of which 2 (0.14% ± 0.03%) were reported as acute gastric dilation of the remnant. Conclusions: Acute gastric dilation of the post-RYGB remnant is a rare complication, but it can be serious. It is necessary to have a high suspicion to obtain an early diagnosis and treatment. Percutaneous gastrostomy is an image-guided procedure that can solve the problem temporarily or permanently.


Assuntos
Derivação Gástrica/efeitos adversos , Dilatação Gástrica/cirurgia , Obesidade Mórbida/cirurgia , Adulto , Feminino , Coto Gástrico/cirurgia , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Cirurgia Assistida por Computador
14.
J Laparoendosc Adv Surg Tech A ; 31(7): 790-795, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32991240

RESUMO

Background: Malignant or benign biliary obstructions can be successfully managed with minimally invasive percutaneous interventions. Since percutaneous approaches are challenging, extensive training using relevant models is fundamental to improve the proficiency of percutaneous physicians. The aim of this experimental study was to develop an in vivo training model in pigs to simulate bile duct dilatation to be used during percutaneous biliary interventions. Materials and Methods: Twenty-eight large white pigs were involved and procedures were performed in an experimental hybrid operating room. Under general anesthesia, animals underwent a preoperative magnetic resonance cholangiography (MRC). Afterward, the common bile duct was isolated and ligated laparoscopically. A postoperative MRC was performed 72 hours after the procedure to evaluate bile duct dilatation. The In vivo models presenting an effective dilatation model were included in the hands-on part of a percutaneous surgery training course. Animals were euthanized at the end of the training session. Results: Postoperative MRC confirmed the presence of bile duct dilatation in the survival pigs (n = 25). No intraoperative complications occurred and mean operative time was 15.8 ± 5.27 minutes. During the course, 27 trainees could effectively perform percutaneous transhepatic cholangiography, bile duct drainage, biliary duct dilatation, and stent placement, with a > 90% success rate, thereby validating the experimental model. All animals survived during the training procedures and complications occurred in 28.3% of cases. Conclusion: The creation of an in vivo bile duct dilatation animal model is feasible with a low short-term mortality. It provides a realistic and meaningful training model in percutaneous biliary procedures.


Assuntos
Procedimentos Cirúrgicos do Sistema Biliar/educação , Colestase/cirurgia , Laparoscopia/educação , Modelos Animais , Cirurgia Assistida por Computador/educação , Animais , Ductos Biliares/cirurgia , Procedimentos Cirúrgicos do Sistema Biliar/métodos , Colangiografia , Colestase/etiologia , Dilatação/métodos , Estudos de Viabilidade , Humanos , Laparoscopia/métodos , Masculino , Cirurgia Assistida por Computador/métodos , Suínos
15.
J Laparoendosc Adv Surg Tech A ; 31(2): 176-182, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33306942

RESUMO

Background: The relationship between obesity with common bile duct stone (CBDS) is close and increases after a Roux-en-Y gastric bypass (RYGB). Due to the anatomical modification, direct endoscopic access is not always possible. For this reason, image-guided surgery (IGS) by percutaneous transhepatic biliary drainage (PTBD) of the common bile duct (CBD) could be a first-line approach for the treatment of post-RYGB choledocholithiasis. The aim of this study was to analyze the feasibility and safety of CBDS treatment after RYGB with IGS. Materials and Methods: We present a descriptive retrospective observational multicentric study on the treatment of choledocholithiasis in patients operated on for RYGB using IGS through a minimally invasive approach by PTBD. The diagnosis of CBDS was made according to the symptoms of the patients, supported by blood tests, and medical images. Treatment was planned in two stages: in the first step, a PTBD was performed, and in the second step the choledocholithiasis was removed. Results: Of a total of 1403 post-RYGB patients, 21 presented choledocholithiasis. Of these, n = 18 were included. Symptoms were reported in n = 15 (8 cholestatic jaundice, 7 cholangitis), whereas n = 3 were asymptomatic. Percutaneous treatment was performed in all these patients, treated with a balloon and stone basket. A hyperamylasemia without pancreatitis was observed in 3 patients. No complications or deaths associated with the procedure were reported. The average hospital stay was 8.6 days. Conclusion: IGS is an interesting option for the treatment CBDS after RYGB. For these patients, PTBD is feasible and safe.


Assuntos
Coledocolitíase/cirurgia , Ducto Colédoco/cirurgia , Obesidade Mórbida/cirurgia , Adulto , Idoso , Feminino , Derivação Gástrica , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/complicações , Estudos Retrospectivos , Cirurgia Assistida por Computador , Resultado do Tratamento
16.
J Laparoendosc Adv Surg Tech A ; 30(9): 967-972, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32609072

RESUMO

Background: Although bariatric surgery is a standardized procedure, it is not without complications. Image-guided surgery allows minimally invasive resolution of complications, making it ideal for bariatric patients. The objective of this work was to analyze the image-guided surgery approach to postoperative complications of bariatric surgery. Materials and Methods: Retrospective comparative study in patients with complications after bariatric surgery. Patients were included consecutively according to selection criteria. All the patients were treated by the same surgical team. Results: n = 58 patients were recruited. The average age was 47.3 (range 16-62) years; the distribution by sex was male 52% and female 48%. Average body mass index was 42% (±1.26). The associated comorbidities were diabetes mellitus 41% (±0.49), dyslipidemia 41% (±0.49), and high blood pressure 39% (±0.48). Of the total, 39 (67.2%) underwent laparoscopic sleeve gastrectomy (LSG) and 19 (32.8%) under Roux-en-Y Gastric Bypass (RYGB) (P ≥ .05). Complications reported were leaks/fistulas (with/without abdominal collections) in 94.8% (±0.22), gallstones 3.5% (±0.18), and hemorrhage 1.7% (±0.13). There was no statistically significant difference between the type of bariatric surgery (LSG versus RYGB) and the complications found (P ≥ .005). There were no intestinal obstructions, strictures or acute gastric dilations, or deaths. The treatment of complications was approached percutaneously (56.9%), endoscopically (29.4%), reoperation laparoscopically (12%), and clinical control (1.7%). Conclusion: The image-guided surgery approach to postoperative complications of bariatric surgery is feasible and safe. Good results are obtained with a decrease in the surgical comorbidities associated with the procedure.


Assuntos
Fístula Anastomótica/cirurgia , Gastrectomia/efeitos adversos , Derivação Gástrica/efeitos adversos , Hemorragia Pós-Operatória/cirurgia , Cirurgia Assistida por Computador/métodos , Adolescente , Adulto , Fístula Anastomótica/etiologia , Índice de Massa Corporal , Endoscopia Gastrointestinal/métodos , Feminino , Cálculos Biliares/etiologia , Cálculos Biliares/cirurgia , Gastrectomia/métodos , Humanos , Laparoscopia/métodos , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/cirurgia , Hemorragia Pós-Operatória/etiologia , Reoperação/métodos , Estudos Retrospectivos , Adulto Jovem
17.
Obes Surg ; 29(7): 2051-2058, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30929199

RESUMO

BACKGROUND: Bariatric surgery offers the only effective long-term weight loss therapy for morbidly obese patients. Numerous studies have demonstrated a mortality and morbidity reduction associated with weight loss surgery, but these interventions also have significant rates of complications. It is important for the bariatric surgeons to recognize these complications and acknowledge which of them can be solved in a minimally invasive manner in order to offer to patients the best treatment. The aim of this article was to review factors and success rates associated with percutaneous image guide abdominal interventions to treat the complications of bariatric surgery. MATERIALS AND METHODS: Retrospective descriptive study. Eighty-two patients with complications after bariatric surgery were included. Of these, 56 presented fistula with or without abdominal collection. RESULTS: Of the total patients, 54% are male and 46% female. The average age was 49.4 (range 16-62). Of the 56 cases, 37 (66.1%) occurred after laparoscopic sleeve gastrectomy, and 19 (33.9%) post-Roux-en-Y gastric bypass. The fistula was resolved by percutaneous image guide abdominal interventions in 49 opportunities, of which 67% required only conservative treatment afterwards, the remaining 33% required endoscopic treatment with prostheses, fibrin sealants, and/or clips. No mortality was reported in the series. CONCLUSION: Percutaneous image-guided abdominal interventions play a significant role in the treatment of complications following bariatric surgery. The minimally invasive treatment of fistula after bariatric surgery is safe and effective.


Assuntos
Fístula Anastomótica/cirurgia , Ablação por Cateter , Fístula/cirurgia , Gastrectomia/efeitos adversos , Derivação Gástrica/efeitos adversos , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/cirurgia , Abdome/diagnóstico por imagem , Abdome/cirurgia , Adolescente , Adulto , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Procedimentos Cirúrgicos do Sistema Digestório/estatística & dados numéricos , Feminino , Fístula/epidemiologia , Fístula/etiologia , Gastrectomia/métodos , Gastrectomia/estatística & dados numéricos , Derivação Gástrica/métodos , Derivação Gástrica/estatística & dados numéricos , Gastroenteropatias/epidemiologia , Gastroenteropatias/etiologia , Gastroenteropatias/cirurgia , Humanos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Laparoscopia/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Reoperação/efeitos adversos , Reoperação/métodos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/estatística & dados numéricos , Resultado do Tratamento , Redução de Peso , Adulto Jovem
18.
Rev. otorrinolaringol. cir. cabeza cuello ; 77(1): 16-26, mar. 2017. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-845642

RESUMO

Introducción: La cirugía guiada por imágenes corresponde a una herramienta quirúrgica que comienza a desarrollarse a mediados del siglo XX. En 1990 comienza a utilizarse en otorrinolaringología, siendo sus principales indicaciones la cirugía endoscópica de cavidades paranasales y la cirugía de base de cráneo anterior. Objetivo: Analizar y presentar el resultado del uso de cirugía guiada por imágenes en pacientes intervenidos en el Hospital Clínico de la Universidad de Chile (HCUCH). Material y método: Se realizó un estudio retrospectivo incluyendo todos los casos de cirugía endoscópica nasosinusal y base de cráneo asistida por imágenes en HCUCH. La selección para usar la navegación se hizo en base a las recomendaciones de la Academia Americana de Otorrinolaringología. Resultados: De un total de 12 pacientes intervenidos con el uso de navegación, se obtuvo 100% de éxito quirúrgico con disminución de los síntomas y sin complicaciones intraoperatorias. Conclusión: La cirugía asistida por navegación en cavidades paranasales y base de cráneo, es una herramienta de suma utilidad en casos seleccionados que potencia las habilidades quirúrgicas del cirujano sin reemplazar sus conocimientos anatómicos. Otorga seguridad y precisión en cirugías que comprometen estructuras nobles como base de cráneo y órbita entre otros.


Introduction: Image Guided Surgery is a surgical tool that develop in the mid-twentieth century. In 1990 it began to be used in otolaryngology, being its main indications endoscopic surgery of paranasal sinuses and anterior skull base. Aim: To analyze and present the result of image-guided surgery in patients undergoing surgery at the Hospital of the University of Chile. Material and method: A retrospective study included all cases of endoscopic sinus surgery and skull base imaging assisted at the Clinical Hospital of the University of Chile from August 2015 to August 2016. The choice to use the navigation was made in based on the recommendations of the American Academy of Otolaryngology, and analyzed case by case. Results: A total of 12 patients were operated using Navigation, achieving 100 % of surgical success with decreased symptoms and without intraoperative complications. Conclusion: Image Guided Surgery in paranasal sinuses and skull base is a tool very useful in selected cases where enhances the surgeon skills without replacing their anatomical knowledge. Provides security and accuracy in surgeries involving noble structures such as the skull base, orbit among others. their anatomical knowledge. Provides security and accuracy in surgeries involving noble structures such as the skull base, orbit among others.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Endoscopia/métodos , Seios Paranasais/cirurgia , Base do Crânio/cirurgia , Cirurgia Assistida por Computador , Estudos Retrospectivos , Resultado do Tratamento
19.
Surg Innov ; 24(1): 66-71, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27729567

RESUMO

INTRODUCTION: Simulated laparoscopy training is limited by its low-quality image. A high-definition (HD) laparoscopic training box was developed under the present necessity of simulating advanced surgery. OBJECTIVE: To describe and test a new HD laparoscopic training box for advanced simulation training. METHODS: We describe the features and image quality of the new training box. The simulator was tested and then evaluated by a group of 76 expert surgeons using a 4-item questionnaire. To assess the effectiveness of training using this simulation box, 15 general surgery residents were trained to perform a laparoscopic jejuno-jejunostomy in a validated simulation program. They were assessed with objective rating scales before and after the training program, and their results were compared with that of experts. RESULTS: The training box was assembled using high-density fiberglass shaped as an insufflated abdomen. It has an adapted full-HD camera with a LED-based illumination system. A manually self-regulated monopod attached to the camera enables training without assistance. Of the expert surgeons who answered the questionnaire, 91% said that the simulation box had a high-quality image and that it was very similar to real laparoscopy. All residents trained improved their rating scores significantly when comparing their initial versus final assessment ( P < .001). Their performance after completing the training in the box was similar to that of experts ( P > .2). CONCLUSIONS: This novel laparoscopic training box presents a high-resolution image and allows training different types of advanced laparoscopic procedures. The simulator box was positively assessed by experts and demonstrated to be effective for laparoscopy training in resident surgeons.


Assuntos
Cirurgia Geral/educação , Internato e Residência , Jejunostomia/educação , Laparoscopia/educação , Treinamento por Simulação , Cirurgia Assistida por Computador/instrumentação , Competência Clínica , Desenho de Equipamento , Humanos
20.
Tech Coloproctol ; 20(1): 11-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26611358

RESUMO

Transanal total mesorectal excision (TME) is an emerging minimally invasive approach to rectal cancer, with encouraging preliminary results. However, the new surgical anatomy of the bottom-up approach complicates surgical understanding and increases the risks of inadvertent injuries to crucial anatomical structures, including nerves. Key elements to improve the safety and stimulate interest in such a complex technique might be robotics and image guidance, to enhance the level of precision. In this editorial, some of the technologies that could be used for precision TME are outlined, in light of the experience of our Institute for Image-Guided Surgery.


Assuntos
Colectomia/métodos , Imageamento Tridimensional/métodos , Medicina de Precisão/métodos , Neoplasias Retais/cirurgia , Reto/cirurgia , Cirurgia Endoscópica Transanal/métodos , Canal Anal/cirurgia , Humanos , Ilustração Médica , Procedimentos Cirúrgicos Robóticos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA