Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
1.
J Esthet Restor Dent ; 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39093128

RESUMO

OBJECTIVE: This article puts forward consensus recommendations from PROSEC North America regarding single indirect restorations made from ceramic and nonmetallic biomaterials in posterior teeth. OVERVIEW: The consensus process involved a multidisciplinary panel and three consensus workshops. A systematic literature review was conducted across five databases to gather evidence. The recommendations, informed by findings from systematic reviews and formulated based on a two-phase e-Delphi survey, emphasize a comprehensive treatment strategy that includes noninvasive measures alongside restorative interventions for managing dental caries and tooth wear. The recommendations advocate for selecting between direct and indirect restorations on a case-by-case basis, favoring inlays and onlays over crowns to align with minimally invasive dentistry principles. The recommendations highlight the critical role of selecting restorative biomaterials based on clinical performance, esthetic properties, and adherence to manufacturer guidelines. They emphasize the importance of precision in restorative procedures, including tooth preparation, impression taking, contamination control, and luting. Regular follow-up and maintenance tailored to individual patient needs are crucial for the longevity of ceramic and nonmetallic restorations. CONCLUSIONS: These PROSEC recommendations provide a framework for dental practitioners to deliver high-quality restorative care, advocating for personalized treatment planning and minimally invasive approaches to optimize oral health outcomes. CLINICAL SIGNIFICANCE: The PROSEC North America recommendations highlight the importance of minimally invasive techniques in posterior tooth restorations using ceramic and non-metallic biomaterials. These principles prioritize tooth structure conservation and personalized treatment planning, essential for enhancing clinical outcomes and long-term oral health.

2.
BMC Oral Health ; 24(1): 1009, 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39210360

RESUMO

TRIAL DESIGN: This is a randomized, controlled, superiority, double-blinded, parallel-group, two-arms trial with an allocation ratio of 1:1. This study aimed to assess whether the cavity design could affect the clinical performance of the CAD/CAM generated indirect resin composite restoration in endodontically treated teeth (ETT) evaluated using the Modified USPHS criteria after a two-year follow up. METHODS: A total of 30 participants who underwent endodontic treatment for MOD cavities in permanent molars were divided randomly into two parallel groups (n = 30 restorations) according to the performed cavity design to group 1 in which there was no cuspal reduction (inlay) and group 2 in which cuspal reduction was performed (overlay). All pulp chambers were filled with bulk fill flowable composite, and the cavities were prepared following the criteria of the cavities for indirect restorations and restored using nano-hybrid composite resin blocks (Brilliant, Coltene, Switzerland). The restorations were evaluated using the modified USPHS criteria at baseline, six months, one-year and two years follow-up visits. For qualitative data, frequencies (n) and percentages (%) were used to display the data, while mean and standard deviation (SD) were used for quantitative data. The normality of the data was evaluated using the Shapiro-Wilk and Kolmogorov-Smirnov tests. For every test, P ≤ 0.05 was used as the significance threshold. RESULTS: Twenty-six individuals completed the follow-up period after receiving the assigned intervention.The inter-group comparison showed that, at the 6- months and 12- months observation points, the overlay design had significantly better marginal adaptation, less incidence of discoloration or tooth/restoration fracture, and similar marginal integrity and caries incidence to the inlay design. After 24- months, the overlay design still had better marginal adaptation, less incidence of discoloration or tooth/restoration fracture and less caries incidence in comparison to the inlay design, while there was no difference in the marginal integrity between either design. CONCLUSIONS AND CLINICAL RELEVANCE: Cuspal reduction in endodontically treated teeth showed better clinical performance than the cusp preservation thus, the former is more reliable.


Assuntos
Resinas Compostas , Preparo da Cavidade Dentária , Restauração Dentária Permanente , Dente não Vital , Humanos , Resinas Compostas/uso terapêutico , Dente não Vital/terapia , Feminino , Preparo da Cavidade Dentária/métodos , Restauração Dentária Permanente/métodos , Masculino , Método Duplo-Cego , Adulto , Dente Molar , Desenho Assistido por Computador , Pessoa de Meia-Idade
3.
BMC Oral Health ; 24(1): 101, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38233771

RESUMO

TRIAL DESIGN: This is a randomized, controlled, superiority, double-blinded, parallel-group, two-arms trial with an allocation ratio of 1:1. The aim of this trial was to compare the two-year clinical performance of partial indirect restorations fabricated from CAD/CAM nano-hybrid composite and ceramic lithium disilicate blocks using the modified USPHS criteria. METHODS: In two parallel groups (n = 50 restorations), fifty participants having mutilated vital teeth with a minimum of two remaining walls were randomly enrolled in this trial and received indirect restorations of either nano-hybrid composite resin blocks (Brilliant, Coltene, Switzerland) or Lithium Disilicate (IPS Emax CAD). The restorations were assessed using modified USPHS criteria by two independent blinded assessors at baseline, six months, one-year and two years follow-up visits. Categorical and ordinal data were presented as frequencies and percentages. Categorical data were analyzed using the chi-square test. Ordinal data were analyzed using the Mann-Whitney U test for intergroup comparisons and Freidman's test followed by the Nemenyi post hoc test for intragroup comparisons. Numerical data were presented as mean and standard deviation values. They were analyzed for normality using the Shapiro-Wilk test. Data were found to be normally distributed and were analyzed using the independent t-test. The significance level was set at p ≤ 0.05 within all tests. RESULTS: Forty-eight participants received the allocated intervention and completed the follow-up periods. There was a statistically significant difference between both tested materials for all USPHS criteria regarding Marginal integrity and Marginal discoloration at six-months Follow-up, but with no statistically significant difference at one- and two-year follow-up. CONCLUSIONS: Both materials showed an acceptable, successful clinical performance along the two-years follow-up period. CLINICAL RELEVANCE: The CAD/CAM nano-hybrid composite blocks are as reliable as Lithium disilicate for restoring mutilated vital teeth.


Assuntos
Porcelana Dentária , Restaurações Intracoronárias , Humanos , Cerâmica , Desenho Assistido por Computador , Materiais Dentários , Teste de Materiais
4.
Odontology ; 112(1): 138-147, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37097420

RESUMO

The aim of this study was to assess the fracture behavior of molar teeth restored with MOD inlays made of experimental short fiber-reinforced CAD/CAM composite block (SFRC CAD) before and after cyclic fatigue aging. Standardized MOD cavities were prepared on 60 intact mandibular molars. Three groups of CAD/CAM made inlay restorations (Cerasmart 270, Enamic, and SFRC CAD) were fabricated (n = 20/group). All restorations were luted with self-adhesive dual-cure resin cement (G-Cem One). Half of restored teeth per each group (n = 10) were quasi-statically loaded until fracture without aging. The other half underwent cyclic fatigue aging for 500,000 cycles (Fmax = 150 N) before being loaded quasi-statically until fracture. Then, the fracture type was visually inspected. The microstructure and elemental content of CAD/CAM materials were assessed using SEM and EDS. Two-way analysis of variance (ANOVA) was used to statistically examine the data, and it was followed by the Tukey HSD test (α = 0.05). ANOVA demonstrated that both material type and aging had a significant effect (p < 0.05) on the load-bearing capacity values of the restorations. Teeth restored with SFRC CAD showed significantly the highest (p < 0.05) load-bearing capacity (2535 ± 830 N) after fatigue aging among all groups. SEM images showed the ability of short fibers in SFRC CAD composite to redirect and hinder crack propagation. With regard to fracture mode, Enamic group revealed 85% of catastrophic failure (vs. 45% and 10% for Cerasmart 270 and SFRC CAD, respectively). Large MOD cavities on molar teeth were most favorably restored with SFRC CAD inlays, yielding the highest load-bearing capacity and more restorable failures.


Assuntos
Cárie Dentária , Restaurações Intracoronárias , Humanos , Restaurações Intracoronárias/métodos , Resinas Compostas/química , Análise do Estresse Dentário , Dente Molar , Desenho Assistido por Computador , Teste de Materiais
5.
J Endod ; 49(12): 1739-1746, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37595683

RESUMO

INTRODUCTION: This study evaluated the resistance to fracture of endodontically treated premolars (ETPs) with mesio-occluso-distal (MOD) cavities filled with nanohybrid composite (NHC), fiber-reinforced composite (FRC), horizontal glass fiber posts (HFP), and ceramic inlays (CI). METHODS: Eighty-four intact maxillary premolars were taken, and endodontic treatment was performed followed by MOD cavity preparations (except in the control group). They were distributed into 7 groups based on type of restoration: intact teeth (control group), ETP + MOD (not restored), NHC, FRC + NHC, HFP + NHC, FRC + HFP + NHC, and CI groups. Samples were subjected to universal testing machine until the fracture occurred and failure mode was visually inspected. RESULTS: Mean and standard deviation of fracture resistance of the 7 groups ranged from 265.6 ± 68.0 N to 1023.7 ± 76.5 N. The highest reading was noted for intact teeth followed by FRC + HFP + NHC group and then the CI group, with no significant difference among the 3 groups. The lowest reading was noted for the ETP + MOD group. Maximum unrepairable fractures were seen in the ETP + MOD and CI groups. CONCLUSION: FRC + HFP + NHC combination and CIs increased the resistance to fracture of ETPs significantly.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Humanos , Restaurações Intracoronárias , Resinas Compostas/uso terapêutico , Dente Pré-Molar , Fraturas dos Dentes/prevenção & controle , Cerâmica , Dente não Vital/terapia , Análise do Estresse Dentário
6.
RGO (Porto Alegre) ; 71: e20230022, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1449017

RESUMO

ABSTRACT The CAD/CAM technology arose from the need to develop materials with better mechanical and optical properties that could be used for making monolithic restorations. Several materials have been used for milling indirect restorations in prefabricated blocks. Among them, lithium silicate reinforced with zirconia. Due to its recent introduction in the market, this case report aimed to present a detailed clinical protocol for the execution of a ceramic onlay of this material using CAD/CAM technology. A 57-year-old female patient sought care with extensive restoration in composite resin (BOMD) of tooth 15 maintained for almost two years. However, due to bruxism, constant dental tightening, the extension of the direct restoration and the need for improved esthetics, it was proposed to replace it with an indirect ceramic onlay restoration. Prophylaxis and choice of the color of the patient's dental substrate were performed. Afterwards, the dental preparation was made and polished. Subsequently, the molding was made with addition silicone and the provisional restoration confectioned. Once the stone model was obtained, it was scanned and the ceramic onlay restoration was milled using CAD/CAM technology. Finally, the restoration was stained and cemented over the preparation. After 2 years, the restoration remained stable, with no evidence of color mismatch, marginal discoloration, marginal cleft, caries or fracture, proving the effectiveness of the treatment in this time interval. The correct indication of the ceramic material combined with the use of CAD/CAM technology facilitated the restorative process, restoring function and the esthetics desired by the patient.


RESUMO A tecnologia CAD/CAM surgiu da necessidade de desenvolvimento de materiais com melhores propriedades mecânicas e ópticas que pudessem ser utilizados para confecção de restaurações monolíticas. Diversos materiais têm sido utilizados para fresagem de restaurações indiretas em blocos pré-fabricados. Dentre eles, o silicato de lítio reforçado com zircônia. Devido a sua recente introdução no mercado, este relato de caso objetivou apresentar um protocolo clínico detalhado para a execução de uma onlay cerâmica desse material utilizando a tecnologia CAD/CAM. Paciente, 57 anos, sexo feminino, procurou atendimento com extensa restauração em resina composta envolvendo as faces (MODV) do dente 15 mantida por quase dois anos. Contudo, em virtude do bruxismo, do apertamento dental constante, da extensão da restauração direta e da necessidade de melhora na estética, foi proposto a substituição por uma restauração indireta em cerâmica do tipo onlay. Foi realizada a profilaxia e escolha da cor do substrato dental da paciente. Em seguida o preparo dental foi confeccionado e polido. Posteriormente foi feita a moldagem com silicone de adição e a confecção do provisório. Com a obtenção do modelo, este foi escaneado e fresada a onlay cerâmica pela tecnologia CAD/CAM, que posteriormente foi maquiada e cimentada sobre o preparo. Após 2 anos, a restauração permaneceu estável, sem evidência de incompatibilidade de cor, descoloração marginal, fenda marginal, cárie ou fratura, comprovando a eficácia do tratamento neste intervalo de tempo. A correta indicação do material cerâmico aliada ao uso da tecnologia CAD-CAM facilitou o processo restaurador devolvendo função e a estética desejada pela paciente.

7.
BMC Med Educ ; 22(1): 841, 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36471301

RESUMO

BACKGROUND: To investigate the effect of virtual simulation systems on the teaching of inlay experiments and to guide the experimental teaching of tooth preparation. METHODS: Participants in their second semester of the junior year were selected to carry out the unified teaching and evaluation of dental preparation theory. The age varied from 18 to 22 years (19.96 ± 0.70) and the participants were randomly divided into four groups (n = 19) with a similar male-to-female ratio following CONSORT guidelines, including a jaw simulation model training group (Group J), a virtual simulation system training group (Group V), a jaw model training first followed by a virtual system training group (Group J-V), and a virtual system followed by a jaw model training group (Group V-J). The inlay tooth preparation assessment was performed on the extracted teeth. The data were analysed according to the assessment scores by a senior clinician. The subjective feelings of the students towards the system were evaluated using questionnaires. RESULTS: The second theoretical scores of Group V-J (63.5 ± 2.89) and Group J-V (60.5 ± 3.25) were higher than those of Group V (57.5 ± 3.13) and Group J (58.0 ± 3.67). The experimental scores of Groups J-V and V-J (62.79 ± 2.84; 64.00 ± 2.85) were higher than those of Groups V and J (56.05 ± 3.39; 55.74 ± 2.53). The questionnaire survey illustrated that most students preferred the digital virtual simulation system (perfect assessment: 91.3%, accuracy: 82.6%, satisfaction: 52.2%). CONCLUSION: Virtual simulation training can facilitate the teaching effect of tooth preparation in inlay experiments, and the teaching mode of Group V-J was the best. Therefore, this teaching mode is to be popularised.


Assuntos
Avaliação Educacional , Treinamento por Simulação , Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Simulação por Computador , Interface Usuário-Computador , Ensino
8.
BMC Oral Health ; 22(1): 635, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-36564766

RESUMO

BACKGROUND: Evaluating the effect of different surface treatment methods on the micro-tensile bond strength (µTBS) of two different resin-matrix computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics (RMCs). METHODS: A standardized inlay preparations were performed on 100 intact maxillary premolars. According to the type of the restorative material, the teeth were randomly divided into two equally sized groups (n = 50): (polymer-infiltrated ceramic (Vita Enamic) and resin-based composites (Lava Ultimate)). The inlays were fabricated using CAD/CAM technology. In each group, the specimens were randomly assigned to five subgroups (n = 10) according to the surface treatment method: group 1 used was the control group (no surface treatment); group 2, was treated with air abrasion with 50 µm Al2O3 (A) and universal adhesive (UA); group 3, was treated with air abrasion with 50 µm Al2O3 (A) and silane coupling agent (S); group 4, was treated with hydrofluoric acid (HF) and universal adhesive (UA) and group 5, was treated with Hydrofluoric acid (HF) + silane coupling agent (S). The inlays were then cemented to their respective preparations using dual-cure self-adhesive resin cement (RelyX U200, 3 M ESPE) according to the manufacturer's instructions. The µTBS test was conducted in all groups, and stereomicroscope and scanning electron microscope were used to inspect the failure mode. The data were statistically analyzed using a two-way analysis of variance (ANOVA) and Tukey's post-hoc multiple comparison tests at a significance level of p < 0.05. RESULTS: Surface treatments significantly increased the µTBS of the materials compared to the control group (p < 0.05). For CAD/CAM RBCs, the µTBS value highest in group 2 whereas, for PICN, the µTBS value was highest in group 3. Cohesive failure of CAD/CAM restorative material was the most predominant mode of failure in all treated groups, whereas adhesive failure at restoration-cement interface was the most predominant failure mode in the control group. CONCLUSION: Surface treatments increase the µTBS of resin-matrix CAD/CAM ceramics to tooth structure. Air abrasion followed by universal adhesive and hydrofluoric acid followed by silane application appears to be the best strategies for optimizing the bond strength of CAD/CAM RBCs and PICN respectively.


Assuntos
Colagem Dentária , Silanos , Humanos , Abrasão Dental por Ar , Cerâmica/química , Desenho Assistido por Computador , Materiais Dentários/química , Dentina , Ácido Fluorídrico/química , Teste de Materiais , Cimentos de Resina/química , Silanos/química , Propriedades de Superfície
9.
Braz. j. oral sci ; 21: e228852, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1392917

RESUMO

Aim: To evaluate the occlusal and internal marginal adaptation of inlay restorations made of different materials, using CAD-CAM. Methods: Preparations were made for MOD inlays of one-third intercuspal width and 4 mm depth in 30 third human molars. The teeth were restored using CAD-CAM materials (n=10) of nanoceramic resin (Lava Ultimate), polymer-infiltrated ceramic network (VITA ENAMIC), or lithium disilicate glass-ceramic (IPS e.max CAD). The specimens were cemented with dual resin cement and sectioned at the center of the restoration, after which the two halves were evaluated, and photographed The occlusal and internal discrepancy (µm) was determined at five points: cavosurface angle of the occlusal-facial wall (CA-O); center of the facial wall (FW); faciopulpal angle (FPA); center of the pulpal wall (PW); and center of the lingual wall (LW). The data were submitted to the Kruskal-Wallis and the Dunn tests (α=0.05). Results: No difference was observed among the materials regarding the occlusal discrepancy at the CA-O, FPA, or PW internal points. The e.max CAD measurement at FW showed larger internal discrepancy than that of Lava (p=0.02). The internal discrepancy at LW was greater for e.max CAD than VITA ENAMIC (p=0.02). Conclusion: Lithium disilicate glass-ceramic presented greater internal discrepancy in relation to the surrounding walls of the inlay preparations


Assuntos
Cerâmica , Desenho Assistido por Computador , Adaptação Marginal Dentária , Materiais Dentários , Restaurações Intracoronárias
10.
J Pharm Bioallied Sci ; 14(Suppl 1): S310-S312, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36110720

RESUMO

Introduction: The extensively damaged teeth can be treated with the inlay and onlay. The ceramic inlays and onlays can be prescribed for the esthetic needs of the patient. Hence in our study, we aim to evaluate clinically the outcomes of the ceramic inlays and onlays for the posterior teeth. Materials and Methods: We piloted a retrospective analytical study from the departmental records. We included 70 patients who had a total of 160 ceramic inlays and onlays prepared between the years 2010-2020. The survival and the failure rates were noted and compared using the "Kruskal-Wallis H statistics and the Chi-square tests" deliberating P < 0.05 as significant. Results: The mean survival was 6.1 ± 1.8 years. The success rate was 92.21% and the failure was 7.6%. Significant variation was seen with the survival rate between the vital and nonvital teeth and between the molars and premolars. Conclusions: The ceramic inlays and onlays were performed successfully in the posterior teeth with a high survival rate and very low failure.

11.
Materials (Basel) ; 15(17)2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36079545

RESUMO

Adequate internal adaptation and marginal sealing of resin luting cements are of particular importance for the success of cemented ceramic inlays. The purpose of this study was to investigate the initial adaptation of different resin cements at the tooth-inlay restoration interface at enamel versus dentin surfaces. Thirty-two extracted human molars were allocated to four groups. One Class II cavity was prepared in each tooth. In each group, half of the cavities' gingival floors were on enamel while the other halves were on cementum. Lava Ultimate CAD/CAM inlays were luted to the cavities using the following adhesive systems: RelyX Unicem, RelyX Ultimate, eCement, and Variolink Esthetic DC. After staining teeth with silver nitrate solution, marginal and internal gap volumes were determined using micro-CT images. Statistical analyses were conducted by independent t test and one-way ANOVA followed by post hoc Tukey test (p < 0.05). The internal and marginal gap volume values were the highest for Variolink Esthetic DC at the dentin surface (0.629 ± 0.363) and (2.519 ± 1.007), respectively, and the lowest for RelyX Unicem at the enamel surface (0.005 ± 0.004) and (0.009 ± 0.003), respectively. The internal and marginal adaptation on the enamel surface for RelyX Unicem and RelyX Ultimate resin cements were comparable to each other and to eCement but significantly better than Variolink Esthetic DC cement. Regardless of the adhesive resin system used, adaptation on enamel is superior to that on dentin surfaces.

12.
Eur J Oral Sci ; 130(3): e12870, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35490397

RESUMO

This study aimed to measure real-time temperature changes in gold-restored teeth compared with intact teeth during the intake of hot and cold drinks. Sixteen molars, including eight natural intact teeth and eight restored teeth with gold inlays, were selected from the participants. Custom-made thermocouple sensors were attached to the coronal third of the buccal surface of teeth. Participants consecutively consumed hot and cold drinks according to a standardized regimen. Resting, maximum, and minimum temperatures; time to reach peak temperatures; and heating and cooling velocities were obtained. Statistical analysis was performed using independent two-sample t-test. Teeth with gold restorations showed a significantly higher maximum temperature (44.7 °C [SD 2.9]) than did natural teeth (40.5 °C [SD 1.2]) during hot water drinking and showed a lower minimum temperature (25.0 °C [SD 4.9]) than did natural teeth (31.5 °C [SD 3.1]) during cold water drinking. The heating and cooling rates for the teeth with gold restorations were two and three times higher than those of the natural teeth. Gold-restored teeth showed greater temperature change than intact teeth in terms of magnitude and velocity in response to temperature changes induced by hot and cold drinks.


Assuntos
Ouro , Dente , Temperatura Baixa , Temperatura Alta , Humanos , Dente Molar , Temperatura , Dente/fisiologia , Água
13.
Adv Mater ; 34(27): e2202180, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35488765

RESUMO

Programmable base pair interactions at the nanoscale make DNA an attractive scaffold for forming hydroxyapatite (HAP) nanostructures. However, engineering macroscale HAP mineralization guided by DNA molecules remains challenging. To overcome this issue, a facile strategy is developed for the fabrication of ultrastiff DNA-HAP bulk composites. The electrostatic complexation of DNA and a surfactant with a quaternary ammonium salt group enables the formation of long-range ordered scaffolds using electrospinning. The growth of 1D and 2D HAP minerals is thus realized by this DNA template at a macroscale. Remarkably, the as-prepared DNA-HAP composites exhibit an ultrahigh Young's modulus of ≈25 GPa, which is comparable to natural HAP and superior to most artificial mineralized composites. Furthermore, a new type of dental inlay with outstanding antibacterial properties is developed using the stiff DNA-HAP. The encapsulated quaternary ammonium group within the dense HAP endows the composite with long-lasting and local antibacterial activity. Therefore, this new type of super-stiff biomaterial holds great potential for oral prosthetic applications.


Assuntos
Compostos de Amônio , Anti-Infecciosos , Antibacterianos/farmacologia , DNA , Durapatita/química , Restaurações Intracoronárias , Engenharia Tecidual , Alicerces Teciduais/química
14.
Clin Oral Investig ; 26(3): 2513-2526, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34643807

RESUMO

OBJECTIVES: This study evaluated the effect of deep margin elevation (DME) and restorative materials (leucite-reinforced glass-ceramics [C] vs. indirect resin composite [R]) on the fatigue behavior and stress distribution of maxillary molars with 2-mm deep proximal margins restored with MOD inlay. METHODS: Fifty-two extracted human third molars were randomly assigned into four groups (n = 13): C; DME + C; R; and DME + R. Inlays were fabricated in CAD-CAM and bonded to all teeth. The fatigue behavior was assessed with the stepwise stress test (10,000 cycles/step; step = 50 N; 20 Hz; initial load = 200 N). Fatigue failure loads and the number of cycles were analyzed with 2-way ANOVA and Tukey's test (p < 0.05) and Kaplan-Meier survival plots. The stress distribution was assessed with finite element analysis. The models were considered isotropic, linear, and homogeneous, and presented bonded contacts. A tripod axial load (400 N) was applied to the occlusal surface. The stress distribution was analyzed with the maximum principal stress criterion. RESULTS: For fatigue, there was no difference for DME factor (p > 0.05). For the material factor, the load and number of cycles for failure were statistically higher in the R groups (p < 0.05). The finite element analysis showed that resin composite inlays concentrated more stress in the tooth structure, while ceramic inlays concentrated more stress in the restoration. Non-reparable failures were more frequent in the resin composite inlays groups. CONCLUSIONS: DME was not negative for fatigue and biomechanical behaviors. Resin composite inlays were more resistant to the fatigue test, although the failure mode was more aggressive. CLINICAL SIGNIFICANCE: DME does not impair mechanical behavior. Resin composite inlays failed at higher loads but with a more aggressive failure mode.


Assuntos
Porcelana Dentária , Restaurações Intracoronárias , Resinas Compostas/química , Porcelana Dentária/química , Análise do Estresse Dentário , Humanos , Teste de Materiais , Dente Molar , Estresse Mecânico
15.
Braz. dent. sci ; 25(3): 1-10, 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1381618

RESUMO

The clinical success of tooth-colored indirect restorations has been confirmed in several studies. However, inlays and onlays restorations in Class II cavities with deep gingival margins can still be considered a clinical challenge. With the purpose of facilitating the execution of the operative procedures in intrasulcular margins and reducing the risk of restorative failures, the technique of cervical margin relocation has been explored as a noninvasive alternative to surgical crown lengthening. This work aims at discussing through a case report the biomechanical, operative and biological aspects in the treatment of teeth with deep gingival margins. Therefore, given the therapy applied in the clinical case presented, it is concluded that the cervical margin relocation with composite resin is advantageous since it eliminates the need for surgery, allowing the implementation of indirect restorations in fewer clinical sessions, not causing damage to periodontal tissues once it provided good finishing and polishing with the establishment of a correct emergence profile, allowing flawless maintenance of gingival health after one year. (AU)


Sucesso clínico das restaurações indiretas livres de metal tem sido confirmado em diversos estudos. No entanto, restaurações parciais indiretas em cavidades do tipo classe II com margens profundas ainda podem ser consideradas um desafio clínico. Com a proposta de facilitar a execução dos procedimentos operatórios em margens intra-sulculares e reduzir a ocorrência de falhas, a técnica de elevação da margem gengival em resina composta tem sido explorada como alternativa não invasiva à cirurgia de aumento de coroa clínica. Este trabalho tem a intenção de discutir através de um relato de caso clínico os aspectos biomecânicos, operatórios e biológicos no tratamento de dentes com margens cervicais profundas. Sendo assim, conclui-se que a técnica de elevação da margem gengival com resina composta é vantajosa, pois elimina a necessidade de cirurgia permitindo a execução de restaurações indiretas em menos sessões clínicas, não gerando danos aos tecidos periodontais, desde que haja um bom acabamento e polimento, com estabelecimento de um correto perfil de emergência. (AU)


Assuntos
Humanos , Feminino , Adulto , Adaptação Marginal Dentária , Resinas Compostas , Falha de Restauração Dentária , Preparo da Cavidade Dentária , Restaurações Intracoronárias
16.
Int J Comput Dent ; 24(4): 429-438, 2021 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-34931778

RESUMO

The significantly faster fabrication technique of chairside restorations with the aid of the Cerec Primemill milling unit makes it possible to restore an entire quadrant in a reasonable amount of time. Furthermore, the procedure described in this article made it possible to use a new type of medium-strength ceramic that achieved a very good esthetic result overall.


Assuntos
Porcelana Dentária , Planejamento de Prótese Dentária , Cerâmica , Desenho Assistido por Computador , Coroas , Estética Dentária , Humanos
17.
J Dent ; 112: 103740, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34233204

RESUMO

OBJECTIVE: The aim of this study was to clinically evaluate the 5-years clinical performance of indirect resin composite inlays luted with three different resin cement strategies in MOD Class II restorations. MATERIALS AND METHODS: A randomized clinical trial was conducted following CONSORT guidelines. Forty patients with three large cavities indicated for indirect MOD Class II restorations were enrolled in the current study. Then, 120 indirect resin composite inlay restorations (SR Nexco) were placed and luted with three different resin cement strategies (n=40); an etch-and-rinse (Variolink N), self-etch (Panavia F2.0) and self-adhesive (RelyX Unicem). These restorations were evaluated to the periods of 1 week (baseline), 1, 3 and 5 years using modified USPHS criteria. Statistical analyses were performed with Wilcoxon and Friedman tests with level of significance set at 0.05. RESULTS: The outcome of the clinical trial showed that, there was neither loss of restorations nor recurrent caries after 5 years for all luting cements groups. Both self-etch Panavia F2.0 and self-adhesive RelyX Unicem resin cements exhibited significant differences between the evaluation periods regarding to marginal discoloration and marginal adaptation (p=0.03). At baseline, only 8 cases of etch-and-rinse (Variolink N) resin cement group exhibited post-operative sensitivity which were relieved after short time (p=0.04). CONCLUSION: All the three resin cement strategies tested, showed acceptable clinical performance after 5-years recall period. In time, etch-and-rinse resin cement group showed better clinical performance regarding marginal discoloration and marginal adaptation at 5-years recall period. Clinical Relevance statement:In vitro and in vivo studies reveal contradictory evidence of the clinical performance of indirect resin composite inlays luted with different resin cement strategies. Thus, this study revealed that etch-and-rinse resin cement still has the best prognosis for adhesive luting of indirect resin composite inlays.


Assuntos
Restaurações Intracoronárias , Cimentos de Resina , Cimentos Dentários , Adesivos Dentinários , Humanos , Estudos Prospectivos
18.
Materials (Basel) ; 14(9)2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34062936

RESUMO

This study evaluated the stress distribution in five different class II cavities of premolar models restored with conventional or bulk-fill flowable composite by means of finite element analysis (FEA) under shrinkage and occlusal loading. An upper validated premolar model was imported in the software, and five class II cavities with different occlusal extensions and dimensions were prepared: horizontal cavity on the mesial surface (horizontal slot), mesio-occlusal cavity, mesial cavity (vertical slot), tunnel type cavity and direct access cavity. The models were restored with conventional or bulk-fill flowable resin composite. The tested materials were considered as homogeneous, linear, and isotropic. The Maximum Principal Stress criteria was chosen to evaluate the tensile stress results. The lowest shrinkage stress value was observed in the direct access cavity restored with bulk-fill flowable resin composite (36.12 MPa). The same cavity, restored with conventional composite showed a score of 36.14 MPa. The horizontal slot cavity with bulk-fill flowable showed a score of 46.71 MPa. The mesio-occlusal cavity with bulk-fill flowable had a score of 53.10 MPa, while with conventional composite this was 55.35 MPa. Higher shrinkage stress was found in the vertical slot cavity with conventional resin 56.14 MPa, followed by the same cavity with bulk-fill flowable 56.08 MPa. Results indicated that the use of bulk-fill flowable composite resin more significantly decreased the polymerization shrinkage stress magnitude. The larger the cavity and the volume of material necessary to restore the tooth, the greater the residual stress on enamel and dentin tissue.

19.
J Prosthodont ; 30(7): 625-631, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33219727

RESUMO

PURPOSE: To evaluate the fracture resistance and failure modes of endodontically treated mandibular molars restored with different designs of inlays, onlays and endocrowns. MATERIALS AND METHODS: Extracted mandibular third molars (n = 180) were used. An access cavity was prepared on the occlusal surface of each tooth and the roots were obturated with gutta percha. All specimens were randomly divided into 6 groups (n = 30/group) according to the cavity design and the restoration material used. C: control group without access cavity preparation. IE: MOD inlay preparation with EverX Posterior (GC Europe) in the pulp chamber. IG: MOD inlay preparation with G-aenial Universal Flo (GC America) in the pulp chamber. OE: onlay preparation with EverX Posterior (GC Europe) in the pulp chamber. OG: onlay preparation with G-aenial Universal Flo (GC America) in the pulp chamber. EC: endocrown with an empty pulp chamber. All restorations were fabricated with CAD/CAM system using CERASMART® (GC Dental products Europe, Belgium) CAD/CAM blocks. Specimens were thermal-cycled and were subjected to a compressive load applied at 30° angle relative to the long axis of the tooth with a universal testing machine. Results were statistically analyzed by ANOVA followed by Tukey post hoc tests. Chi-square test and Fisher Exact tests were used for the comparisons among groups. RESULTS: The mean fracture strength was significantly different between the groups (p < 0.001); it was significantly highest for intact teeth, followed by endocrowns (p = 0.021). The strength was significantly lower for inlays (with G-aenial Universal Flo and EverX Posterior), intermediate for onlays with EverX Posterior followed by onlays with G-aenial Universal Flo. CONCLUSIONS: Endocrowns exhibited higher fracture resistance than other tested composite resin groups. Endocrowns and onlays showed a more favorable failure mode than inlay restorations.


Assuntos
Fraturas dos Dentes , Dente não Vital , Resinas Compostas , Porcelana Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Europa (Continente) , Humanos , Restaurações Intracoronárias , Teste de Materiais , Fraturas dos Dentes/prevenção & controle
20.
J Shoulder Elbow Surg ; 30(8): e517-e530, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33220411

RESUMO

BACKGROUND: Polyethylene (PE) wear and material degradation have been reported as complications in reverse total shoulder replacements (rTSAs). In this regard, scapular notching is associated with more clinical complications. Therefore, the purposes of the study were to quantify the linear and volumetric wear, as a measure for the amount of removed material, and to qualitatively assess the PE damage modes to describe the material degradation in retrieved rTSA humeral PE inlays that contribute to failure of shoulder replacements. Furthermore, this study aimed to evaluate the effect of scapular notching on PE wear and rim damage of the humeral components. METHODS: The total study population of 39 humeral inlays contains 2 cohorts that were used for the damage mode analysis and for the wear analysis, respectively. The extent and presence of wear damage modes in 5 defined zones were assessed by a grading system for all PE joint replacements. For quantitative wear analysis the most frequent design (n = 17) was chosen. Using a coordinate-measuring machine and postprocessing software, volumetric wear measurements for the retrieved humeral PE inlays were undertaken. Furthermore, prerevision radiographs were analyzed for scapular notching. Finally, retrieval findings were correlated with clinical and radiographic data to consider the effect of notching and to identify risk of failures for these prostheses. RESULTS: Damage on the rim of the humeral PE inlays was more frequent and severe than on the intended articulation surface. Irrespective of the damage mode, the inferior rim zone sustained the greatest amount of wear damage followed by the posterior zone. Burnishing, scratching, pitting, and embedded particles are most likely to occur in the articular surface area, whereas surface deformation, abrasion, delamination and gross material degradation are predominantly present in the inferior and posterior rim zones. The retrieved inlays exhibited a mean volumetric wear rate of 296.9 mm³/yr ± 87.0 mm³/yr. However, if the notched and non-notched components were compared, a significant higher volumetric wear rate (296.5 ± 106.1 mm³/yr) was found for the notched components compared to the non-notched group (65.7 ± 7.4 mm³/yr). Generally, there was a significantly greater incidence of damage and greater amount of wear if scapular notching occurred. CONCLUSION: The notched components showed a 5-fold increase in PE wear rate. Therefore, scapular notching has a strong effect on PE damage and wear. If scapular notching can be clinically avoided, the PE wear performance is in a similar magnitude as found for hip and knee replacements.


Assuntos
Artroplastia do Ombro , Artroplastia de Substituição , Articulação do Ombro , Artroplastia de Substituição/efeitos adversos , Artroplastia do Ombro/efeitos adversos , Humanos , Úmero , Polietileno , Desenho de Prótese , Escápula , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA