Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 152
Filtrar
1.
BMC Anesthesiol ; 24(1): 221, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961365

RESUMO

BACKGROUND: This study aimed to evaluate the accuracy of ankle blood pressure measurements in relation to invasive blood pressure in the lateral position. METHODS: This prospective observational study included adult patients scheduled for elective non-cardiac surgery under general anesthesia in the lateral position. Paired radial artery invasive and ankle noninvasive blood pressure readings were recorded in the lateral position using GE Carescape B650 monitor. The primary outcome was the ability of ankle mean arterial pressure (MAP) to detect hypotension (MAP < 70 mmHg) using area under the receiver operating characteristic curve (AUC) analysis. The secondary outcomes were the ability of ankle systolic blood pressure (SBP) to detect hypertension (SBP > 140 mmHg) as well as bias (invasive measurement - noninvasive measurement), and agreement between the two methods using the Bland-Altman analysis. RESULTS: We analyzed 415 paired readings from 30 patients. The AUC (95% confidence interval [CI]) of ankle MAP for detecting hypotension was 0.88 (0.83-0.93). An ankle MAP of ≤ 86 mmHg had negative and positive predictive values (95% CI) of 99 (97-100)% and 21 (15-29)%, respectively, for detecting hypotension. The AUC (95% CI) of ankle SBP to detect hypertension was 0.83 (0.79-0.86) with negative and positive predictive values (95% CI) of 95 (92-97)% and 36 (26-46)%, respectively, at a cutoff value of > 144 mmHg. The mean bias between the two methods was - 12 ± 17, 3 ± 12, and - 1 ± 11 mmHg for the SBP, diastolic blood pressure, and MAP, respectively. CONCLUSION: In patients under general anesthesia in the lateral position, ankle blood pressure measurements are not interchangeable with the corresponding invasive measurements. However, an ankle MAP > 86 mmHg can exclude hypotension with 99% accuracy, and an ankle SBP < 144 mmHg can exclude hypertension with 95% accuracy.


Assuntos
Anestesia Geral , Tornozelo , Determinação da Pressão Arterial , Humanos , Feminino , Anestesia Geral/métodos , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Determinação da Pressão Arterial/métodos , Tornozelo/irrigação sanguínea , Idoso , Oscilometria/métodos , Pressão Sanguínea/fisiologia , Hipertensão/fisiopatologia , Hipertensão/diagnóstico , Hipotensão/diagnóstico , Hipotensão/fisiopatologia , Adulto , Posicionamento do Paciente/métodos
2.
Surg Neurol Int ; 15: 138, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38742009

RESUMO

Background: More than 700,000 people suffer from vertebral compression fractures attributed to osteoporosis, metastatic disease, or trauma each year in the United States, and undergo kyphoplasty. They are typical. These often undergo kyphoplasty to treat resultant pain or new neurological deficits. Here, we present three patients who, due to significant comorbidities, underwent kyphoplasty performed in the lateral decubitus rather than the prone position. Case Description: Three females, two with metastatic cancer and one with osteoporosis, presented with lumbar compression fractures and new accompanying pain and/or neurological deficits. Due to significant accompanying comorbidities, kyphoplasty was safely and effectively performed in all three patients utilizing the lateral decubitus rather than the prone position. Conclusion: Although vertebral kyphoplasties are typically performed in the prone position, here, we present three patients who, due to significant comorbidities, safely and effectively underwent kyphoplasties performed in the lateral decubitus position.

3.
Heliyon ; 10(9): e30019, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38694024

RESUMO

Backgroud: Hypotension is one of the most common and dangerous complications following combined spinal epidural anesthesia during elective cesarean delivery. Many methods are used to prevent or treat the hypotension with pharmacological or non-pharmacological measures. Our aim was to assess left-lateral position and phenylephrine prophylactic treatment for the prevention or treatment of maternal hypotension. Methods: A total of 127 pregnant women were enrolled to be analyzed. The primary outcome measure was the incidence of maternal hypotension and secondary outcome measures included maternal demographic characteristics, anesthesia-to-incision time interval, birthweight and Apgar scores. Results: The incidence of hypotension was 65.4 % in sequential reactive treatment and only 11.3 % achieved complete anesis after left-lateral position, significantly higher than 17.4 % in left-lateral position combined phenylephrine prophylactic treatment (P < 0.001). The increasing in gestational age may decrease the hypotension risk (P < 0.001). There were no significantly differences with maternal age, gravidity, parity, BMI before pregnancy, BMI before cesarean section, anesthesia-to-incision time interval, birthweight and Apgar scores (P > 0.05). The univariate logistic regression analysis revealed a significant association between treatment and hypotension (OR 0.11, 95 % CI 0.05-0.27). After adjusting for confounding variables, the risk of hypotension was decreased in subjects with treatment (OR 0.1, 95 % CI 0.04-0.25; OR 0.15, 95 % CI 0.05-0.43; OR 0.16, 95 % CI 0.05-0.46). The results of stratified and interaction analyses of the association between treatment revealed no interactive role from maternal age, gravidity and BMI before cesarean section (P > 0.05). Conclusions: Single use of left-lateral position had limited effective and left-lateral position combined prophylactic phenylephrine used may be much better to prevent or treat hypetension, but larger studies with more robust data are needed to confirm these findings.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38554997

RESUMO

BACKGROUND: Displaced humeral shaft fractures are frequently treated by osteosynthesis in the active patient. We aimed to evaluate the results of intramedullary nailing (IMN) in the lateral position with the Neviaser approach and to compare them with those from IMN nailing in the standard position and conventional approach. METHODS: In the retrospectively evaluated, single-center study, we compared 20 cases of long IMN for fractures of the proximal or middle third of the humerus shaft (Multilock; Synthes Laboratory) in the lateral position with the percutaneous Neviaser approach with 52 cases of IMN in the standard position. The mean age of patients was 62 ± 21 years. Clinical outcomes were analyzed: Constant score, subjective shoulder evaluation score and range of motion. Radiographically, entry point at the proximal part of the humerus, the healing rate and the possible association between the critical shoulder angle (CSA) and the correct positioning of the nail were assessed. RESULTS: With a mean follow-up of 26 ± 2 months, the healing rate was 89% (64/72) in the overall series, (eight patients in non-union), with no difference between the two groups. The overall mean active anterior elevation (AAE) was 125 ± 22°, mean external rotation (ER1) was 35 ± 17°, and mean internal rotation (IR) was at L3. The mean Constant score was 58 ± 23 and subjective shoulder evaluation score 73 ± 12%. ranges of motion were better in the lateral than standard position group (AAE 133 ± 17 vs. 122 ± 23, P = .03; ER1 47 ± 13 vs. 30 ± 16, P < .001; IR T12 vs. L5, P = .02). The nail was less often protruding in the lateral than standard position group (1/20 [5%] vs. 20/52 [38.5%], P = .002). The nail was better positioned from the anteroposterior view (nail centered: 16/20 [75%] vs. 26/52 [50%], P = .047) and lateral view (nail centered: 18/20 [90%] vs. 34/52 [65.4%], P = .02) in the lateral than standard position group. We found no association between nail position, type of approach and CSA. CONCLUSIONS: In the short-term follow-up, osteosynthesis of humeral shaft fractures by using long IMN in the lateral position with the Neviaser approach is a reliable technique. The positioning of the nail, in particular its entry point, and the clinical results were better with the lateral position and Neviaser approach than with the standard position and conventional approach. Further studies with a larger number of patients, assessment of the learning curve, and analysis of the impact of this technique on comorbidities (unchanged cerebral perfusion) are needed to fully validate this technique.

6.
Eur J Orthop Surg Traumatol ; 34(3): 1529-1534, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38265742

RESUMO

INTRODUCTION: Calcaneus is the most commonly fractured tarsal bone. Open reduction and internal fixation of the displaced intra-articular fractures is considered the gold standard treatment. The lateral extensile approach is the most commonly used approach, and usually, the patients are kept in lateral decubitus position. Recent study has descried calcaneus fracture fixation utilizing the lateral extensile approach with the patient in prone position. The aim of this study was to compare the postoperative radiological outcome, reoperation rate, operative and anesthesia time, infection and the wound complications rate between the two groups. METHODS: The data of 49 adult patients with unilateral closed calcaneus fracture underwent open reduction and internal fixation using lateral extensile approach were collected. Postoperative Bohler's, Gissane angles and complications rate were compared between the two groups. RESULTS: A total of 49 patients were included. Lateral position was utilized in 26 patients (53.1%), while 23 patients (46.9%) were operated in prone position. Majority of the patients were males 87.8% (43 patients), and the mean age of the patients was 31.12 ± 7.50. The most commonly mechanism of injury was fall from height in (91.8%) of the patients. The mean preoperative Bohler's angle was 9.33 ± 13.07 and increased to 22.69 ± 9.15 postoperatively. The mean preoperative angle of Gissane was 130.45 ± 26.98 whereas it was 124.76 ± 17.20 postoperatively. The mean postoperative Bohler's angle and angle of Gissane were significantly higher among patient who underwent fixation in lateral position (25.88 ± 6.62, 137.15 ± 11.17) when compared to the prone one (19.09 ± 10.35, 110.74 ± 10.81). There was no significant difference between the two groups regarding the reoperation rate (p 0.947), infection (p 0.659, operative time (p 0.688), anesthesia time (p 0.522) and wound complications (p 0.773). CONCLUSION: Surgical restoration of the Bohler's and Gissane's angles with the patient placed in the lateral decubitus position remains superior to the prone position with no difference in the complication rate between the two groups.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Calcâneo , Traumatismos do Pé , Fraturas Ósseas , Fraturas Intra-Articulares , Adulto , Masculino , Humanos , Feminino , Calcâneo/diagnóstico por imagem , Calcâneo/cirurgia , Calcâneo/lesões , Estudos Retrospectivos , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fraturas Intra-Articulares/diagnóstico por imagem , Fraturas Intra-Articulares/cirurgia , Posicionamento do Paciente , Resultado do Tratamento
7.
EClinicalMedicine ; 67: 102402, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38261940

RESUMO

Background: Approximately one-third of patients who undergo double-lumen tube (DLT) intubation in the conventional supine position experience DLT malposition. No randomized study investigates the effect of DLT intubation in the lateral position. We therefore aimed to evaluate the effect of intubation in lateral position on placement of a DLT compared to supine intubation, and to test primary hypothesis that lateral DLT intubation could reduce the incidence of DLT malposition. Methods: We randomly allocated 108 patients undergoing video-assisted thoracic surgery to receive DLT intubation in the comfortable and surgically required lateral position (lateral group) or in the supine position (supine group) from October to December 2022. The primary outcome was the incidence of DLT malposition defined as movement >1.0 cm to correct the DLT position. The secondary outcomes included intubation time, the frequency and duration of fibreoptic bronchoscopy, the need for re-intubation, intra-operative vital signs, and post-operative recovery. This trial is registered with the Chinese Clinical Trial Registry (ChiCTR2200060794). Findings: The incidence of DLT malposition was significantly lower in the lateral group (1/53 [2%]) than that in the supine group (16/53 [30%]; RR [95% confidence interval] of 0.06 [0.01-0.46]; P < 0.001). Lateral DLT intubation decreased the intubation time, the frequency and duration of fibreoptic bronchoscopy. The incidence of hypotension, post-operative sore throat, and upper-arm discomfort was lower in the lateral group. Other secondary outcomes were similar between groups. Interpretation: Lateral DLT intubation reduced the incidence of DLT malposition for patients undergoing video-assisted thoracic surgery. These results support that lateral DLT intubation offers more benefits and may be a superior option compared to conventional supine intubation. Funding: National Natural Science Foundation of China and of Zhejiang Province.

8.
Asian J Surg ; 47(1): 373-379, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37696694

RESUMO

BACKGROUND: Double-lumen tube (DLT) intubation in lateral decubitus position is rarely reported. We designed this study to evaluate the feasibility of VivaSight double-lumen tube (VDLT) intubation assisted by video laryngoscope in lateral decubitus patients. METHODS: Patients undergoing elective video-assisted thoracoscopic surgery (VATS) for lung lobectomy were assessed for eligibility between January 2022 and December, 2022. Eligible patients were randomly allocated into supine intubation group (group S) and lateral intubation group (group L) by a computer-generated table of random numbers. The prime objective was to observe whether the success rate of VDLT intubation in lateral position with the aid of video laryngoscope was not inferior to that in supine position. RESULTS: A total of 116 patients were assessed, and 88 eligible patients were randomly divided into group L (n = 44) and group S (n = 44). The success rate of the first attempt intubation in the L group was 90.5%, lower than that of S group (97.7%), but there was no statistical difference (p > 0.05). Patients in both groups were intubated with VDLT for no more than 2 attempts. The mean intubation time was 91.98 ± 26.70 s in L group, and 81.39 ± 34.35 s in S group (p > 0.05). The incidence of the capsular malposition in the group L was 4.8%, less than 36.4% of group S (p < 0.001). After 24 h of follow-up, it showed a higher incidence of sore throat in group S, compared to that in group L (p = 0.009). CONCLUSION: Our study shows the comprehensive success rate of intubation in lateral decubitus position with VDLT assisted by video laryngoscope is not inferior to that in supine position, with less risk of intraoperative tube malposition and postoperative sore throat. TRIAL REGISTRATION: Chinese Clinical Trail Register (ChiCTR2200062989).


Assuntos
Laringoscópios , Faringite , Humanos , Laringoscópios/efeitos adversos , Estudos de Viabilidade , Intubação Intratraqueal/efeitos adversos , Faringite/etiologia , Pulmão
9.
Trials ; 24(1): 762, 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38012708

RESUMO

BACKGROUND: High-flow nasal oxygen (HFNO) therapy is a leading treatment technique for acute hypoxemic respiratory failure (AHRF), but its treatment failure rate remains high. The awake prone position (APP) has been proven to increase oxygenation and reduce the endotracheal intubation rate in patients with COVID-19-induced AHRF. However, the APP is poorly tolerated in patients, and its performance in improving prognoses is controversial. The lateral position has a similar mechanism and effect to the prone position, but it is more tolerable than the prone position. Therefore, it is worth exploring whether the lateral position is better for awake patients with AHRF. METHODS: This is a protocol for a three-arm parallel-group multicentre randomised controlled open-label exploratory trial. A total of 583 patients from two hospitals in Chongqing, China, will be randomised to take the semi-recumbent position, lateral position, or prone position at a ratio of 1:1:1. Patients are all diagnosed with AHRF secondary to non-COVID-19 pneumonia or lung infection and receiving HFNO therapy. The primary outcome is ventilator-free days in 28 days. The secondary outcomes are the 28-day intubation rate, 28-day all-cause mortality, total position change time, the incidence of adverse events, number of hours using HFNO therapy, length of hospital and intensive care unit (ICU) stay, and others. We will conduct subgroup analyses on the arterial partial pressure of oxygen to the fraction of inspiration oxygen (PaO2/FiO2) ratio (> 200 mmHg or ≤ 200 mmHg), time from admission to intervention implementation (< 24 h or ≥ 24 h), position changing time, and different diagnoses. DISCUSSION: This trial will explore the prognostic effects of the APP with that of the lateral position in awake patients with non-COVID-19AHRF and compare the differences between them. To provide evidence for clinical decision-making and further research on position management. TRIAL REGISTRATION: This trial was registered in the Chinese Clinical Trial Registry. The registration number is ChiCTR2200055822 . Registered on January 20, 2022.


Assuntos
COVID-19 , Insuficiência Respiratória , Humanos , Oxigênio/uso terapêutico , SARS-CoV-2 , COVID-19/terapia , Insuficiência Respiratória/terapia , Insuficiência Respiratória/tratamento farmacológico , Oxigenoterapia/efeitos adversos , Oxigenoterapia/métodos , Decúbito Ventral , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
10.
J Ultrasound Med ; 42(10): 2341-2347, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37269215

RESUMO

OBJECTIVE: We aim to evaluate the effect of right lateral position on fetal hemodynamics (including umbilical artery [UA] and middle cerebral artery (MCA) blood flow-velocity waveform). METHODS: In total, 150 low-risk singleton full-term pregnant women were included in the study from November 2021 to January 2022. Doppler flow velocity waveforms of the fetal UA and MCA tested by ultrasound were collected in gestation of 37-40 weeks. Computational analysis was performed using the one-way ANOVA test. RESULTS: Compared with the maternal left lateral position, there was a significant increase in Doppler indices of UA-RI (P = .033), UA-S/D (P = .019) and MCA-PSV (P = .021) and a significant decrease in MCA-RI (P = .030) in the supine position group. There was no statistical significance in all Doppler indices between the left and right lateral position (P > .05). Among the Doppler indices of three different maternal positions, there was no significance in both UA-PI and MCA-PI (P > .05). CONCLUSION: There were no significant differences on changes of the fetal hemodynamics between left and right lateral positions. Pregnant women could adopt to lie in the left or right lateral position alternately to relieve the discomfort in late pregnancy.


Assuntos
Feto , Hemodinâmica , Gravidez , Feminino , Humanos , Idade Gestacional , Feto/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Artéria Cerebral Média/diagnóstico por imagem , Artérias Umbilicais/diagnóstico por imagem , Ultrassonografia Pré-Natal
11.
Asian Spine J ; 17(4): 770-781, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37226380

RESUMO

Spine surgery has advanced tremendously over the last decade. The number of spine surgeries performed each year has also been increasing constantly. Unfortunately, the reporting of position-related complications in spine surgery has also been steadily increasing. These complications not only result in significant morbidity for the patient but also raises the risk of litigation for the surgical and anesthetic teams. Fortunately, most position-related complications are avoidable with basic positioning knowledge. Hence, it is critical to be cautious and take all necessary precautions to avoid position-related complications. We discuss the various position-related complications associated with the prone position, which is the most commonly used position in spine surgery, in this narrative review. We also discuss the various methods for avoiding complications. Furthermore, we briefly discuss less commonly used positions in spine surgery, like the lateral and sitting positions.

12.
Physiol Rep ; 11(9): e15685, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37144602

RESUMO

Cerebral perfusion is maintained at a consistent value irrespective of changes in systemic blood pressure or disease-induced changes in general physical condition. This regulatory mechanism is effective despite postural changes, working even during changes in posture, such as those from sitting to standing or from the head-down to the head-up position. However, no study has addressed changes in perfusion separately in the left and right cerebral hemispheres, and there has been no specific investigation of the effect of the lateral decubitus position on perfusion in each hemisphere. Surgery, particularly respiratory surgery, is often performed with the patient in the lateral decubitus position, and since intraoperative anesthesia may also have an effect, it is important to ascertain the effect of the lateral decubitus position on perfusion in the left and right cerebral hemispheres in the absence of anesthesia. The effects of the lateral decubitus position on heart rate, blood pressure, and hemodynamic in the left and right cerebral hemispheres assessed by regional saturation of oxygen measured by near-infrared spectroscopy were investigated in healthy adult volunteers. Although the lateral decubitus position causes systemic circulatory changes, it may not cause any difference in hemodynamic between the left and right cerebral hemispheres.


Assuntos
Hemodinâmica , Postura , Humanos , Adulto , Postura/fisiologia , Pressão Sanguínea/fisiologia , Frequência Cardíaca , Voluntários
13.
Orthop Rev (Pavia) ; 15: 74116, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37064045

RESUMO

Total Hip Arthroplasty (THA) may be performed through various approaches; however, depending on the surgical position of the patient, the superiority of lateral or supine position is still debated. The aim of this systematic review and meta-analysis was to compare the supine versus lateral position in THA in terms of intraoperative and postoperative outcomes and component placement. The systematic literature search was performed by the use of Cochrane Central, Pub-Med-Medline, and Google Scholar in order to select studies that evaluated clinical outcomes and the outliers of cup alignment for inclination and anteversion between supine and lateral position for hip arthroplasty. Finally, 9 articles were included in this review. The meta-analysis showed no significant differences between the two groups for clinical outcomes, unless for blood loss and VAS (respectively p = 0.05 and p = 0.004 in favour of lateral decubitus). Regarding the number of outliers, the supine decubitus showed significant differences only for the cup anteversion (p = 0.01). However, more prospective studies with a longer follow-up that analyze both clinical and radiological parameters are needed to assess the superiority of supine or lateral patient position for total hip arthroplasty.

14.
J Clin Med ; 12(7)2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37048557

RESUMO

The minimum bronchial cuff volume (BCVmin) of a double-lumen tube (DLT) without air leaks during lung isolation may vary among individuals, and lateral positioning could increase the bronchial cuff pressure (BCP). We investigated the effect of initially established BCVmin (BCVi) on the change in BCP by lateral positioning. Seventy patients who underwent elective lung surgery were recruited and divided into two groups according to the BCVi obtained during anesthetic induction in each patient. Outcome analysis was conducted using data from 39 patients with a BCVi greater than 0 (BCVi > 0 group) and 27 with a BCVi of 0 (BCVi = 0 group). The primary outcome was a change in the value measured in the supine and lateral positions of the initially established BCP (BCPi; BCP at the time of BCVi injection), which was significantly larger in the BCVi > 0 group than in the BCVi = 0 group (1.5 (0.5-6.0) cmH2O vs. 0.0 (0.0-1.0) cmH2O; p < 0.001). BCVi was related to the left main bronchus (LMB) diameter (Spearman's rho = 0.676, p < 0.001) and the gap between the LMB diameter and the outer diameter of the bronchial cuff (Spearman's rho = 0.553, p < 0.001). Therefore, selecting a DLT size with a bronchial cuff that fits each patient's LMB may be useful in minimizing the change in BCP when performing lateral positioning during thoracic surgery. If the bronchial cuff requires unavoidable initial inflation, it is necessary to be aware that BCP may increase during lateral positioning and to monitor the BCP regularly if possible.

15.
Sensors (Basel) ; 23(3)2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36772761

RESUMO

In this paper, a variety of 2D materials on the surface plasmon resonance sensor based on Al-Ni bimetallic layer are compared. Simulation results indicate that lateral position shift, which is calculated according to the real and imaginary parts of the refractive index of material, can be used as an effective parameter to optimize the sensitivity. By using the parameters for optimizing the SPR structures, the results show that the multiple layer models of Al(40 nm)-Ni(22 nm)-black phosphorus (BP)(1 L) and Al(40 nm)-Ni(22 nm)-blue phosphorus (BlueP)/WS2(1 L) exhibit average angular sensitivities of 507.0 °/RIU and 466 °/RIU in the refractive index range of 1.330-1.335, and maximum sensitivity of 542 °/RIU and 489 °/RIU at the refractive index of 1.333, respectively. We expect more applications can be explored based on the highly sensitive SPR sensor in different fields of optical sensing.

16.
Spine Surg Relat Res ; 7(1): 66-73, 2023 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-36819631

RESUMO

Introduction: Since 2015, we have performed minimally invasive oblique lateral interbody fusion (OLIF) at L5/S1 for various lumbosacral spine disorders using percutaneous pedicle screws. This study evaluated the clinical and radiologic results between OLIF at L5/S1 and minimally invasive transforaminal interbody fusion (MIS-TLIF) for single to multilevel degenerative lumbosacral disorders. Methods: A total of 124 patients underwent either OLIF (62 cases) or MIS-TLIF (62 cases). The applied disorders were L5 isthmic spondylolisthesis, foraminal stenosis, pseudarthrosis, adjacent segment degeneration, a combination of L4/5 and L5/S1 pathology, and others. We performed OLIF with posterior percutaneous fixation in the same lateral position. MIS-TLIF was performed with modified cortical bone trajectory screws. The operation time (OT), estimated blood loss (EBL), JOABPEQ effectiveness rate (%),Visual Analog Scale (VAS), fusion rate, radiologic segmental alignment, and complications were evaluated. Results: The average follow-up periods were 51 and 69 months (24-95) in the OLIF and MIS-TLIF groups, respectively. Furthermore, the average fused segments were 1.6 and 1.5 in each group, respectively. The OT and EBL per segment were 130 min and 56 mL and 100 min and 64 mL, respectively. The JOABPEQ effectiveness rate in the OLIF group demonstrated a statistically higher value in the domains of pain, low-back function, and gait than the MIS-TLIF group (P<0.01). The follow-up VAS of low-back pain (LBP) and lower extremity numbness had lower values in the OLIF group (P<0.05). The fusion rates were 98% and 90%, respectively. Segmental lordosis at L5/S1 was significantly larger in the OLIF group (15° vs. 11°, P<0.01). Conclusions: The OLIF group demonstrated less pain as well as better low-back and gait functions at follow-up. The minimally invasive anterolateral fusion employing OLIF at L5/S1 using percutaneous screws serves as a viable and effective procedure with less residual LBP and high fusion rate.

17.
Trials ; 24(1): 67, 2023 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-36710355

RESUMO

BACKGROUND: The double-lumen tube (DLT) is an essential equipment for thoracic anesthesia and the precise position of DLT placement is particularly important for anesthesia and surgery. However, the incidence of DLT malposition remains high and it leads to lung isolation failure and hypoxemia during one-lung ventilation. This trial aims to explore the clinical application and efficacy of intubation in the lateral position under general anesthesia induction to reduce the incidence of DLT malposition in patients undergoing unilateral video-assisted thoracic surgery (VATS). METHODS: In this prospective, single-center, parallel group, randomized, controlled trial, we will recruit 108 patients, aged 18-80 years, scheduled for elective unilateral VATS with DLT intubation under general anesthesia, and they will be randomly assigned to two groups: a lateral DLT intubation group (group L) and a conventional supine DLT intubation group (group C). The left-sided DLT will be used to intubate in patients of both groups. The position of DLT will be confirmed and adjusted by using the fiberoptic bronchoscopy (FOB). The primary outcome is the incidence of DLT malposition observed via the FOB, and the secondary outcomes include the time of intubation, the frequency and duration of re-adjustments of DLT placement under FOB, whether to re-intubate, intraoperative vital signs, and postoperative recovery. DISCUSSION: Accurate DLT positioning is crucially important for thoracic surgery, but the incidence of DLT malposition is still high in the present clinical practice of thoracic anesthesia. This trial aims to investigate whether lateral DLT intubation can reduce the incidence of DLT malposition, with more stable intraoperative vital signs and less postoperative complications. TRIAL REGISTRATION: The study protocol was registered at Chinese Clinical Trial Registry ( http://www.chictr.org.cn ) with registration number: ChiCTR2200060794 on June 11, 2022.


Assuntos
Intubação Intratraqueal , Cirurgia Torácica Vídeoassistida , Humanos , Anestesia Geral , Broncoscopia , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Cirurgia Torácica Vídeoassistida/efeitos adversos , Cirurgia Torácica Vídeoassistida/métodos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
18.
Eur J Orthop Surg Traumatol ; 33(2): 381-384, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35024951

RESUMO

BACKGROUND: Femoral intramedullary nailing is traditionally performed with the patient supine on a fracture table. We aimed to describe a case series of femoral intramedullary nailing for fracture in the lateral position, with discussion of the operative technique. METHODS: A retrospective analysis identified 52 patients who underwent femoral intramedullary nailing performed in a lateral position without traction over a 5-year period at a single level 1 trauma center. Medical records were reviewed for demographics, blood loss including need for transfusion, operative duration, complications, length of stay, fracture union, re-operation and death. RESULTS: There were 24 subtrochanteric, 16 peri-trochanteric and 12 diaphyseal femoral fractures. Mean operative time was 136.2 ± 101.4 min with a mean estimated blood loss of 372.5 ± 349.6 ml. Seventeen patients required blood transfusion. Mean length of stay was 10.3 ± 8.1 days. There were 3 (5.8%) surgical (compartment syndrome, infection and retained drain) and 12 (23.1%) medical complications, with a 30-day mortality rate of 3.8% (2). Mean follow-up was 9.9 ± 8.7 months. The union rate was 94.2% (49) and 3.8% (2) patients required revision fixation (hardware exchange for irritation and exchange nailing for non-union). Discharge destination was home, rehabilitation center and specialized nursing facility in 21 (40.4%), 16 (30.8%) and 15 (28.8%) patients, respectively. DISCUSSION AND CONCLUSION: Femoral intramedullary nailing in the lateral decubitus position is a useful technique of managing peri-trochanteric, subtrochanteric and diaphyseal femoral fractures. We describe a known technique with technical tips, which has distinct advantages over traditional supine positioning especially in certain patient and fracture types. In addition, operative times, blood loss, length of stay, revision and outcomes were comparable to the literature.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/métodos , Estudos Retrospectivos , Fêmur , Fraturas do Fêmur/cirurgia , Tração , Resultado do Tratamento , Pinos Ortopédicos
19.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-991034

RESUMO

Objective:To assess the safety and feasibility of complete lateral position endoscopic combined intra-renal surgery (ECIRS) in treatment of staghorn kidney calculi.Methods:The clinical data of 105 patients with staghorn kidney calculi from March 2016 to July 2022 in the First Hospital of Shanxi Medical University were retrospectively analyzed. Among them, 55 patients were treated with lateral position percutaneous nephrolithotomy (PCNL) (PCNL group), and 50 patients were treated with complete lateral position ECIRS (ECIRS group). The operative time, removal time of double J-tube, postoperative hospital stay, postoperative hemoglobin decrease value, operative complications (using Clavien-Dindo grading criteria), additional postoperative intervention and calculi free rate were compared between two groups.Results:Both groups of patients were successfully operated. The operative time, postoperative hemoglobin decrease value and rate of additional postoperative intervention in ECIRS group were significantly lower than those in PCNL group: (98.3 ± 19.1) min vs. (103.4 ± 16.5) min, (9.34 ± 3.04) g/L vs. (12.55 ± 4.75) g/L and 8.00% (4/50) vs. 21.82% (12/55), the calculi free rate was significantly higher than that in PCNL group: 90.00% (45/50) vs. 74.55% (41/55), and there were no statistical differences ( P<0.05 or <0.01); there were no statistical differences in the removal time of double J-tube, postoperative hospital stay, incidence of Clavien-Dindo≥ grade Ⅱ operative complications between two groups ( P>0.05). Conclusion:The complete lateral position ECIRS is a safe and effective treatment for staghorn kidney calculi, and is a good complement to the ECIRS technique because of its high stone free rate in phase Ⅰ, low complication incidence and easy dissemination.

20.
J Spine Surg ; 9(4): 463-471, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-38196723

RESUMO

Single-prone-lateral (PL) positioning is a new technique that allows for simultaneous anterior and posterior lumbar spine surgery. However, there is a concern regarding the risk of lumbar plexus injury in PL positioning. This study compared the risk of lumbar plexus damage and the overall safety profile of a modified PL (mPL) position to the standard PL (sPL) position for lateral lumbar spine fusion surgery. A crossover soft cadaveric study was conducted with two raters examining the comparative outcomes of position A: sPL and position B: mPL. The mPL position differs from the sPL position in that the ipsilateral arm is placed at the side of the body rather than above the head. To assess positive results (no lumbar plexus injury) between positions A and B, a mixed effects logistic regression model was utilized. The odds ratio of a good result between positions B and A was also determined. The odds ratio of the favorable outcome between position B and A was 1.77, indicating significantly higher odds of a favorable outcome in the modified position B than in the control or position A. The mPL positioning outperformed the sPL positioning in terms of safety and efficacy for lateral lumbar spine fusion. The mPL positioning may reduce the risk of lumbar plexus injury by allowing for a more direct approach to the lumbar spine and by avoiding excessive stretching of the lumbar plexus.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...