Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
World J Gastrointest Surg ; 16(6): 1933-1938, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38983322

RESUMO

BACKGROUND: The combination of magnetic compression anastomosis (MCA) and endoscopy has been used to treat biliary stricture after liver transplantation. However, its use for the treatment of complex biliary obstruction after major abdominal trauma has not been reported. This case report describes the successful use of MCA for the treatment of biliary obstruction resulting from major abdominal trauma. CASE SUMMARY: A 23-year-old man underwent major abdominal surgery (repair of liver rupture, right half colon resection, and ileostomy) following a car accident one year ago. The abdominal drainage tube, positioned at the Winslow foramen, was draining approximately 600-800 mL of bile per day. During the two endoscopic retrograde cholangiopancreatography procedures, the guide wire was unable to enter the common bile duct, which prevented placement of a biliary stent. MCA combined with endoscopy was used to successfully achieve magnetic anastomosis of the peritoneal sinus tract and duodenum, and then a choledochoduodenal stent was placed. Finally, the external biliary drainage tube was removed. The patient achieved internal biliary drainage leading to the removal of the external biliary drainage tube, which improved the quality of life. CONCLUSION: Magnetic compression technique can be used for the treatment of complex biliary obstruction with minimal operative trauma.

2.
World J Gastrointest Surg ; 16(6): 1926-1932, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38983326

RESUMO

BACKGROUND: The treatment of postoperative anastomotic stenosis after excision of rectal cancer is challenging. Endoscopic balloon dilation and radial incision are not effective in all patients. We present a new endoscopy-assisted magnetic compression technique (MCT) for the treatment of rectal anastomotic stenosis. We successfully applied this MCT to a patient who developed an anastomotic stricture after radical resection of rectal cancer. CASE SUMMARY: A 50-year-old man had undergone laparoscopic radical rectal cancer surgery at a local hospital 5 months ago. A colonoscopy performed 2 months ago indicated that the rectal anastomosis was narrow due to which ileostomy closure could not be performed. The patient came to the Magnetic Surgery Clinic of the First Affiliated Hospital of Xi'an Jiaotong University after learning that we had successfully treated patients with colorectal stenosis using MCT. We performed endoscopy-assisted magnetic compression surgery for rectal stenosis. The magnets were removed 16 d later. A follow-up colonoscopy performed after 4 months showed good anastomotic patency, following which, ileostomy closure surgery was performed. CONCLUSION: MCT is a simple, non-invasive technique for the treatment of anastomotic stricture after radical resection of rectal cancer. The technique can be widely used in clinical settings.

3.
World J Gastrointest Surg ; 16(5): 1336-1343, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38817276

RESUMO

BACKGROUND: Magnetic anchor technique (MAT) has been applied in laparoscopic cholecystectomy and laparoscopic appendectomy, but has not been reported in laparoscopic partial hepatectomy. AIM: To evaluate the feasibility of the MAT in laparoscopic left lateral segment liver resection. METHODS: Retrospective analysis was conducted on the clinical data of eight patients who underwent laparoscopic left lateral segment liver resection assisted by MAT in our department from July 2020 to November 2021. The Y-Z magnetic anchor devices (Y-Z MADs) was independently designed and developed by the author of this paper, which consists of the anchor magnet and magnetic grasping apparatus. Surgical time, intraoperative blood loss, intraoperative accidents, operator experience, postoperative incision pain score, postoperative complications, and other indicators were evaluated and analyzed. RESULTS: All eight patients underwent a MAT-assisted laparoscopic left lateral segment liver resection, including three patients undertaking conventional 5-port and five patients having a transumbilical single-port operation. The mean operation time was 138 ± 34.32 min (range 95-185 min) and the mean intraoperative blood loss was 123 ± 88.60 mL (range 20-300 mL). No adverse events occurred during the operation. The Y-Z MADs showed good workability and maneuverability in both tissue and organ exposure. In particular, the operators did not experience either a "chopstick" or "sword-fight" effect in the single-port laparoscopic operation. CONCLUSION: The results show that the MAT is safe and feasible for laparoscopic left lateral segment liver resection, especially, exhibits its unique abettance for transumbilical single-port laparoscopic left lateral segment liver resection.

4.
World J Gastrointest Surg ; 16(5): 1443-1448, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38817285

RESUMO

BACKGROUND: The treatment of postoperative anastomotic stenosis (AS) after resection of colorectal cancer is challenging. Endoscopic balloon dilation is used to treat stenosis in such cases, but some patients do not show improvement even after multiple balloon dilations. Magnetic compression technique (MCT) has been used for gastrointestinal anastomosis, but its use for the treatment of postoperative AS after colorectal cancer surgery has rarely been reported. CASE SUMMARY: We report a 72-year-old man who underwent radical resection of colorectal cancer and ileostomy one year ago. An ileostomy closure was prepared six months ago, but colonoscopy revealed a narrowing of the rectal anastomosis. Endoscopic balloon dilation was performed three times, but colonoscopy showed no significant improvement in stenosis. The AS was successfully treated using MCT. CONCLUSION: MCT is a minimally invasive method that can be used for the treatment of postoperative AS after colorectal cancer surgery.

5.
World J Gastroenterol ; 30(16): 2272-2280, 2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38690021

RESUMO

BACKGROUND: The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula (TEF), but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control. We designed a T-shaped magnet system to overcome these problems and verified its effectiveness via animal experiments. AIM: To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs. METHODS: Twelve beagles were randomly assigned to groups in which magnets of the T-shaped scheme (study group, n = 6) or normal magnets (control group, n = 6) were implanted into the trachea and esophagus separately under gastroscopy. Operation time, operation success rate, and accidental injury were recorded. After operation, the presence and timing of cough and the time of magnet shedding were observed. Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing, and gross specimens of TEFs were obtained. Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery, and gross specimens were obtained. Fistula size was measured in all animals, and then harvested fistula specimens were examined by hematoxylin and eosin (HE) and Masson trichrome staining. RESULTS: The operation success rate was 100% for both groups. Operation time did not differ between the study group (5.25 min ± 1.29 min) and the control group (4.75 min ± 1.70 min; P = 0.331). No bleeding, perforation, or unplanned magnet attraction occurred in any animal during the operation. In the early postoperative period, all dogs ate freely and were generally in good condition. Dogs in the control group had severe cough after drinking water at 6-9 d after surgery. X-ray indicated that the magnets had entered the stomach, and gastroscopy showed TEF formation. Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm ± 1.29 mm (range, 3.52-6.56 mm). HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas. Dogs in the study group did not exhibit obvious coughing after surgery. X-ray examination 2 wk after surgery indicated fixed magnet positioning, and gastroscopy showed no change in magnet positioning. The magnets were removed using a snare under endoscopy, and TEF was observed. Gross specimens showed well-formed fistulas with a diameter of 6.11 mm ± 0.16 mm (range, 5.92-6.36 mm), which exceeded that in the control group (P < 0.001). Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining, and the structure was more regular than that in the control group. CONCLUSION: Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets. Most importantly, this model offers better controllability, which improves the flexibility of follow-up studies.


Assuntos
Modelos Animais de Doenças , Imãs , Traqueia , Fístula Traqueoesofágica , Animais , Cães , Fístula Traqueoesofágica/cirurgia , Fístula Traqueoesofágica/patologia , Fístula Traqueoesofágica/etiologia , Traqueia/cirurgia , Traqueia/patologia , Esôfago/cirurgia , Esôfago/patologia , Esôfago/diagnóstico por imagem , Gastroscopia/instrumentação , Gastroscopia/métodos , Duração da Cirurgia , Masculino , Magnetismo/instrumentação , Desenho de Equipamento , Humanos
6.
Sci Rep ; 14(1): 10602, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719935

RESUMO

Although the application of magnetic compression anastomosis is becoming increasingly widespread, the magnets used in earlier studies were mostly in the shape of a whole ring. Hence, a deformable self-assembled magnetic anastomosis ring (DSAMAR) was designed in this study for gastrointestinal anastomosis. Furthermore, its feasibility was studied using a beagle model. The designed DSAMAR comprised 10 trapezoidal magnetic units. Twelve beagles were used as animal models, and DSAMARs were inserted into the stomach and colon through the mouth and anus, respectively, via endoscopy to achieve gastrocolic magnamosis. Surgical time, number of failed deformations, survival rate of the animals, and the time of magnet discharge were documented. A month later, specimens of the anastomosis were obtained and observed with the naked eye as well as microscopically. In the gastrocolic anastomosis of the 12 beagles, the procedure took 65-120 min. Although a deformation failure occurred during the operation in one of the beagles, it was successful after repositioning. The anastomosis was formed after the magnet fell off 12-18 days after the operation. Naked eye and microscopic observations revealed that the anastomotic specimens obtained 1 month later were well-formed, smooth, and flat. DSAMAR is thus feasible for gastrointestinal anastomosis under full endoscopy via the natural orifice.


Assuntos
Anastomose Cirúrgica , Estudos de Viabilidade , Animais , Cães , Anastomose Cirúrgica/métodos , Estômago/cirurgia , Imãs , Magnetismo , Cirurgia Endoscópica por Orifício Natural/métodos , Cirurgia Endoscópica por Orifício Natural/instrumentação , Colo/cirurgia , Masculino
7.
World J Gastroenterol ; 30(6): 599-606, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38463020

RESUMO

BACKGROUND: Treatment of postoperative anastomotic stenosis for colorectal cancer is often challenging, especially for patients who do not respond well to endoscopy. In cases where patients have undergone an enterostomy, the stenosis can be easily resolved through magnetic compression. However, common magnetic compression techniques cannot be performed on those without enterostomy. We designed a novel Y-Z deformable magnetic ring (Y-Z DMR) and successfully applied it to a patient with a stenosis rectal anastomosis and without enterostomy after rectal cancer surgery. CASE SUMMARY: We here report the case of a 57-year-old woman who had undergone a laparoscopic radical rectum resection (Dixon) for rectal cancer. However, she started facing difficulty in defecation 6 months after surgery. Her colonoscopy indicated stenosis of the rectal anastomosis. Endoscopic balloon dilation was performed six times on her. However, the stenosis still showed a trend of gradual aggravation. Because the patient did not undergo an enterostomy, the conventional endoscopic magnetic compression technique could not be performed. Hence, we implemented a Y-Z DMR implemented through the anus under single channel. The magnetic ring fell off nine days after the operation and the rectal stenosis was relieved. The patient was followed up for six months and reported good defecation. CONCLUSION: The Y-Z DMR deformable magnetic ring is an excellent treatment strategy for patients with rectal stenosis and without enterostomy.


Assuntos
Laparoscopia , Neoplasias Retais , Humanos , Feminino , Pessoa de Meia-Idade , Constrição Patológica/cirurgia , Constrição Patológica/etiologia , Neoplasias Retais/complicações , Neoplasias Retais/cirurgia , Reto/diagnóstico por imagem , Reto/cirurgia , Laparoscopia/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Complicações Pós-Operatórias/etiologia , Fenômenos Magnéticos , Estudos Retrospectivos
8.
BMC Gastroenterol ; 24(1): 20, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38182996

RESUMO

BACKGROUND: To investigate the feasibility of a deformable self-assembled magnetic anastomosis ring (DSAMAR), designed and developed by us, for endoscopic gastrointestinal bypass anastomosis. METHODS: Ten experimental pigs were used as model animals. The DSAMAR comprises 10 trapezoidal magnetic units, arranged in a straight line under the constraint of a guide wire. When the desired anastomosis site is reached under the guidance of an endoscope, the catheter pushes the magnetic unit along the guide wire. The linear DSAMAR can be assembled into a circular DSAMAR. Two DSAMARs were inserted, one at the end of the duodenum and the other into the stomach successively. They attracted each other and compressed the wall of the stomach and duodenum to establish gastrointestinal bypass anastomosis. The experimental pigs were euthanized 4 weeks after the operation, and the gastrointestinal bypass anastomosis specimens were obtained. The anastomosis formation was evaluated by the naked eye and histology. RESULTS: Gastrointestinal bypass anastomosis with DSAMARs was successfully performed. The average operation time under an endoscope was 70.30 ± 19.05 min (range: 43-95 min). The DSAMARs were discharged through the anus 10-17 days after surgery. There were no complications such as gastrointestinal bleeding, perforation, anastomotic fistula, and gastrointestinal obstruction during and after the operation. Gastroscopy and gross specimen of the anastomosis showed a well-formed magnetic anastomosis. Histological observation showed good continuity of the serous membrane and the mucosa of magnetic anastomosis. CONCLUSION: The DSAMAR is a safe and feasible device for fashioning gastrointestinal bypass anastomosis in this animal model.


Assuntos
Gastroscopia , Estômago , Suínos , Animais , Anastomose Cirúrgica , Estômago/cirurgia , Duodeno , Fenômenos Magnéticos
9.
World J Gastrointest Endosc ; 15(11): 658-665, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38073763

RESUMO

BACKGROUND: Gastric cancer (GC) has high morbidity and mortality. Moreover, because GC has no typical symptoms in the early stages, most cases are already in the advanced stages by the time the symptoms appear, thus resulting in poor prognosis and a low survival rate. Endoscopic submucosal dissection (ESD) can realize the early detection and diagnosis of GC and become the main surgical method for early GC. However, ESD has a steep learning curve and high technical skill requirements for endoscopists, which is not conducive to its widespread implementation and advancement. Therefore, a series of auxiliary techniques have been derived. AIM: To evaluate the safety and efficacy of magnetic anchor technique (MAT)-assisted ESD in early GC. METHODS: This was an ex vivo animal experiment. The experimental models were the isolated stomachs of pigs, which were divided into two groups, namely the study group (n = 6) with MAT-assisted ESD and the control group (n = 6) with traditional ESD. Comparing the total surgical time, incidence of surgical complications, complete mucosal resection rate, specimen size, and the scores of endoscopist's satisfaction with the procedure reflected their feelings about convenience during the surgical procedure between the two groups. The magnetic anchor device for auxiliary ESD in the study group comprised three parts, an anchor magnet (AM), a target magnet (TM), and a soft tissue clip. Under gastroscopic guidance, the soft tissue clip and the TM were delivered to the pre-marked mucosal lesion through the gastroscopic operating hole. The soft tissue clip and the TM were connected by a thin wire through the TM tail structure. The soft tissue clip was released by manipulating the operating handle of the soft tissue clip in a way that the soft tissue clip and the TM were fixed to the lesion mucosa. In vitro, ESD is aided by maneuvering the AM such that the mucosal dissection surface is exposed. RESULTS: The total surgical time was shorter in the study group than in the control group (26.57 ± 0.19 vs 29.97 ± 0.28, P < 0.001), and the scores of endoscopist's satisfaction with the procedure were higher in the study group than in the control group (9.53 ± 0.10 vs 8.00 ± 0.22, P < 0.001). During the operation in the study group, there was no detachment of the soft tissue clip and TM and no mucosal tearing. The magnetic force between the AM and TM provided good mucosal exposure and sufficient tissue tension for ESD. The mucosal lesion was completely peeled off, and the operation was successful. There were no significant differences in the incidence of surgical complications (100% vs 83.3%), complete mucosal resection rate (100% vs 66.7%, P = 0.439), and specimen size (2.44 ± 0.04 cm vs 2.49 ± 0.02, P = 0.328) between the two groups. CONCLUSION: MAT-ESD is safe and effective for early GC. It provides a preliminary basis for subsequent internal animal experiments and clinical research.

10.
J Pediatr Surg ; 2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37968150

RESUMO

BACKGROUND: To assess the feasibility of a deformable self-assembled magnetic anastomosis ring (DSAMAR) in the treatment of esophageal stenosis in beagle dogs via transoral access without temporary gastrostomy. METHODS: Experimental esophageal stenosis was created in 10 beagle dogs by partial cervical esophageal ligation. The DSAMAR was inserted into the distal esophagus via the narrow section of the esophagus using a gastroscope. A circular DSAMAR was placed in the proximal esophagus. The magnetic rings on both sides of the experimental stenosis automatically attracted each other. We then recorded the operation time, postoperative complications, anastomotic formation time, and magnetic ring discharge time. The dogs were euthanized 4 weeks postoperatively; subsequently, we obtained the esophageal anastomotic specimens and observed the anastomotic formation via the naked eye and by light microscopy. RESULTS: Our esophageal stenosis model produced reproducible stenoses in all dogs, which was confirmed via endoscopy and esophagography. DSAMAR was successfully implanted in all experimental animals under endoscopic and X-ray monitoring, and all linear DSAMARs were successfully transformed into rings. The magnets at both ends of the esophageal stenosis were automatically attracted. All animals survived until euthanasia. No complications, including esophageal perforation, bleeding, and gastrointestinal obstruction, were noted during the perioperative period. The mean operation time of endoscopic magnetic anastomosis was 15.6 ± 2.41 (range, 12-19) min. The mean esophageal anastomotic formation time was 8.8 ± 1.03 (range, 7-10) days, and the mean expulsion time of DSAMAR was 13.94 ± 2.88 (range, 10-19) days. Gastroscopy and esophagography were performed at 4 weeks postoperatively; the esophageal patency was good. Macroscopic observation of the esophageal anastomotic specimens revealed that the esophageal mucosal layer of the anastomosis had good continuity and the anastomosis was smooth. CONCLUSION: DSAMAR is a feasible option for magnetic recanalization of esophageal stricture via transoral access without temporary gastrostomy.

11.
Front Surg ; 10: 1253728, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37942002

RESUMO

Since the 1970s, magnetic force has been used to augment modern surgical techniques with the aims of minimizing surgical trauma and optimizing minimally-invasive systems. The majority of current clinical applications for magnetic surgery are largely centered around gastrointestinal uses-such as gastrointestinal or bilioenteric anastomosis creation, stricturoplasty, sphincter augmentation, and the guidance of nasoenteric feeding tubes. However, as the field of magnetic surgery continues to advance, the development and clinical implementation of magnetic devices has expanded to treat a variety of non-gastrointestinal disorders including musculoskeletal (pectus excavatum, scoliosis), respiratory (obstructive sleep apnea), cardiovascular (coronary artery stenosis, end-stage renal disease), and genitourinary (stricture, nephrolithiasis) conditions. The purpose of this review is to discuss the current state of innovative magnetic surgical devices under clinical investigation or commercially available for the treatment of non-gastrointestinal disorders.

12.
World J Gastrointest Endosc ; 15(10): 584-592, 2023 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-37900117

RESUMO

BACKGROUND: Esophageal cancer has high incidence globally and is often diagnosed at an advanced stage. With the widespread application of endoscopic technologies, the need for early detection and diagnosis of esophageal cancer has gradually been realized. Endoscopic submucosal dissection (ESD) has become the standard of care for managing early tumors of the esophagus, stomach, and colon. However, due to the steep learning curve, difficult operation, and technically demanding nature of the procedure, ESD has currently been committed to the development of various assistive technologies. AIM: To explore the feasibility and applicability of magnetic anchor technique (MAT)-assisted ESD for early esophageal cancer. METHODS: Isolated pig esophagi were used as the experimental model, and the magnetic anchor device was designed by us. The esophagi used were divided into two groups, namely the operational and control groups, and 10 endoscopists completed the procedure. The two groups were evaluated for the following aspects: The total operative time, perforation rate, rate of whole mucosal resection, diameter of the peering mucosa, and scores of endoscopists' feelings with the procedure, including the convenience, mucosal surface exposure degree, and tissue tension. In addition, in the operational group, the soft tissue clip and the target magnet (TM) were connected by a thin wire through a small hole at the tail end of the TM. Under gastroscopic guidance, the soft tissue clip was clamped to the edge of the lesioned mucosa, which was marked in advance. By changing the position of the anchor magnet (AM) outside the esophagus, the pulling force and pulling direction of the TM could be changed, thus exposing the mucosal peeling surface and assisting the ESD. RESULTS: Herein, each of the two groups comprised 10 isolated esophageal putative mucosal lesions. The diameter of the peering mucosa did not significantly differ between the two groups (2.13 ± 0.06 vs 2.15 ± 0.06, P = 0.882). The total operative time was shorter in the operational group than in the control group (17.04 ± 0.22 min vs 21.94 ± 0.23 min, P < 0.001). During the entire experiment, the TM remained firmly connected with the soft tissue clip and did not affect the opening, closing, and release of the soft tissue clip. The interaction between the TM and AM could provide sufficient tissue tension and completely expose the mucosa, which greatly assists the surgeon with the operation. There was no avulsion of the mucosa, and mucosal lesions were intact when peeled. Therefore, the scores of endoscopists' feelings were higher in the operational group than in the control group in terms of the convenience (9.22 ± 0.19 vs 8.34 ± 0.15, P = 0.002), mucosal surface exposure degree (9.11 ± 0.15 vs 8.25 ± 0.12, P < 0.001), and tissue tension (9.35 ± 0.13 vs 8.02 ± 0.17, P < 0.001). The two groups did not significantly differ in the perforation rate and rate of whole mucosal resection. CONCLUSION: We found MAT-assisted ESD safe and feasible for early esophageal cancer. It could greatly improve the endoscopic operation experience and showed good clinical application prospects.

13.
World J Gastroenterol ; 29(33): 5005-5013, 2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37731993

RESUMO

BACKGROUND: Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis, there is no report on a single-approach operation using the natural orifice. AIM: To design a deformable self-assembled magnetic anastomosis ring (DSAMAR) for colonic anastomosis for use in single-approach operation and evaluate its feasibility and safety through animal experiments. METHODS: The animal model for colonic stenosis was prepared by partial colonic ligation in eight beagles. The magnetic compression anastomosis of their colonic stricture was performed by endoscopically assisted transanal implantation of the DSAMAR. The anastomotic specimen, obtained 2 wk after the operation, was observed by both the naked eye and a light microscope. RESULTS: The DSAMAR was successfully inserted into the proximal end of colon stenosis through the anus. The DSAMAR of seven dogs was successfully transformed into rings, while that of the remaining dog was removed after the first deformation failed. The rings were successfully retransformed after optimization. All animals underwent colonic anastomosis using the DSAMAR. No device-related or procedure-related adverse events were observed. The colostomy specimens of the experimental dogs were obtained 2 wk after the operation. Both gross and histological observations showed good anastomotic healing. CONCLUSION: The DSAMAR is a safe and feasible option for the treatment of colon stenosis. Its specific deformation and self-assembly capability maximize the applicability of the minimally invasive treatment.


Assuntos
Endoscopia , Obstrução Intestinal , Animais , Cães , Constrição Patológica/cirurgia , Anastomose Cirúrgica , Fenômenos Magnéticos
14.
World J Gastrointest Surg ; 15(7): 1286-1293, 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37555113

RESUMO

BACKGROUND: Hepatic portal blood flow occlusion is a common technique for reducing hepatic hemorrhage during hepatectomy. We designed a novel Y-Z magnetic hepatic portal blocking band (Y-Z MHPBB) based on the principle of magnetic compression technique. AIM: To introduce the Y-Z MHPBB device and verify the feasibility of this device for hepatic portal blood flow occlusion in dogs. METHODS: Ten beagles were randomly divided into the experimental group and control group. The operation time, intraoperative blood loss, the number of portal blood flow occlusions, the total time spent on adjusting the blocking band, and the average time spent on adjusting the blocking band were recorded. The surgeons evaluated the feasibility and flexibility of the two portal occlusion devices. RESULTS: Laparoscopic hepatectomy was successfully performed in both the experimental group and control group. There was no statistical difference between the two groups in the operation time, intraoperative blood loss, and the number of hepatic portal blood flow occlusions. With respect to the total time spent on adjusting the blocking band and the average time spent on adjusting the blocking band, the experimental group showed significantly better outcomes than the control group, with a statistical difference (P < 0.05). The operators found that the Y-Z MHPBB was superior to the modified T-tube in terms of operational flexibility. CONCLUSION: The Y-Z MHPBB seems to be an ingenious design, accurate blood flow occlusion effect, and good flexibility; and it can be used for hepatic portal blood flow occlusion during laparoscopic hepatectomy.

15.
World J Gastrointest Surg ; 15(7): 1294-1303, 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37555127

RESUMO

BACKGROUND: Magnetic compression anastomosis (MCA) is a simple procedure contributing to a reliable anastomosis. However, digestive-tract reconstruction after total gastrectomy using MCA has not yet been reported. AIM: To investigate the feasibility of MCA for simultaneous esophagojejunostomy and jejunojejunostomy after total gastrectomy using beagle dogs. METHODS: Sixteen beagles were randomly divided into an MCA group (study group, n = 8) and a manual-suture anastomosis group (control group, n = 8). Two different magnetic anastomosis devices were used in the study group for esophagojejunal and jejunojejunal anastomoses. Both devices included a pair of circular daughter and parent magnets each. The time of esophagojejunostomy and jejunojejunostomy, postoperative complications, and survival rate of the two groups were compared. The dogs were sacrificed one month after the operation and their anastomotic specimens were obtained. Healing was observed by the naked eye and a light microscope. RESULTS: Digestive-tract reconstruction after total gastrectomy was successfully completed in both groups (survival rate = 100%). In the study group, esophagojejunal and jejunojejunal anastomoses took 6.13 ± 0.58 and 4.06 ± 0.42 min, respectively, significantly lower than those in the control group (15.63 ± 1.53 min, P < 0.001 and 10.31 ± 1.07 min, P < 0.001, respectively). Complications such as bleeding, anastomotic leakage, and anastomotic stenosis were not observed. In the study group, the magnets did not interfere with each other. Discharge time of the jejunojejunal magnetic anastomosis device was 10.75 ± 1.28 d, while that of the esophagojejunal magnetic anastomosis device was 12.25 ± 1.49 d. Residual silk was found in the control group. The study group showed a greater smoothness of the anastomosis than that of the control group. All layers of anastomosis healed well in both groups. CONCLUSION: MCA is a safe and feasible procedure for digestive-tract reconstruction after total gastrectomy in this animal model.

16.
Obes Surg ; 33(7): 2261-2265, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37209389

RESUMO

BACKGROUND: Sleeve gastrectomy is one of the most popular bariatric surgeries. With the advent of new technologies, a reduced-port approach assisted by magnets for sleeve gastrectomy (RPSG-MA) has been developed. The aim of our study is to compare the short-term results of RPSG-MA vs conventional laparoscopic SG (CLSG). METHODS: A comparative study was performed. We compared two groups who underwent RPSG-MA (n=150) and CLSG (n=135) between January 2020 and January 2022. RESULTS: Both groups were similar in body mass index, age, sex, and type of comorbidities. The operative time was similar in both groups (RPSG-MA, 52.5 min vs CLSG, 52.9 min; p = 0.829). Length of hospital (1.07 days) stay was significantly shorter in the RPSG-MA group (p = 0.00) than in the CLSG group (1.51 days). There were no conversions to open surgery in any patient or any fatal event. Complications encountered were similar in both groups postoperative. There were minor adverse events directly related to the magnetic device in 3 cases, these being mild hepatic lacerations, resolved with hemostatic measures. CONCLUSION: The magnet-assisted reduced-port gastric sleeve compared to the conventional technique has proven to be safe, technically feasible and with multiple benefits.


Assuntos
Cirurgia Bariátrica , Laparoscopia , Obesidade Mórbida , Humanos , Obesidade Mórbida/cirurgia , Laparoscopia/métodos , Gastrectomia/métodos , Cirurgia Bariátrica/métodos , Fenômenos Magnéticos , Estudos Retrospectivos , Resultado do Tratamento
17.
Surg Endosc ; 37(2): 1005-1012, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36085384

RESUMO

BACKGROUND: There have been no prospective randomized controlled clinical trials evaluating the advantages of the magnetic anchor technique (MAT) used in reduced-port laparoscopic cholecystectomy (LC). The present study evaluated a novel magnetic anchor device designed by the authors. METHODS: Between April 2019 and June 2020, 60 patients with gallbladder diseases participated in a single-center, prospective, randomized controlled clinical trial. The patients were randomly apportioned to undergo either 2-port LC assisted by the novel MAT (MAT-2P-LC, experimental group) or conventional 3-port LC (3P-LC, control). The groups were compared regarding operative time, postoperative complications, surgical incision pain score (Wong-Baker), and other indicators. The patients were followed for 2 years. RESULTS: The test and control groups were comparable in age, gender, body mass index, and primary disease. No patient in the MAT-2P-LC group was converted to 3P-LC. No patients were converted to laparotomy. On the first postoperative day, the Wong-Baker pain score of the experimental group (1.60 ± 0.67) was significantly lower than that of the control (2.20 ± 0.76; P = 0.002). The groups were statistically similar regarding intraoperative blood loss; operative time; time to leave bed; hospital stay; postoperative pain scores at 1 and 4 weeks; and complications. CONCLUSIONS: This rigorous clinical trial shows that the novel MAT used to assist reduced-port LC significantly reduced postoperative pain, but has no obvious advantages in other terms. Clinical Trails.gov. number, ChiCTR1800019464.


Assuntos
Colecistectomia Laparoscópica , Doenças da Vesícula Biliar , Humanos , Colecistectomia Laparoscópica/métodos , Doenças da Vesícula Biliar/cirurgia , Dor Pós-Operatória/cirurgia , Complicações Pós-Operatórias/cirurgia , Duração da Cirurgia , Tempo de Internação , Fenômenos Magnéticos
18.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1005813

RESUMO

【Objective】 Digestive tract reconstruction after total gastrectomy is complicated and causes many complications. This study aimed to investigate the feasibility, safety and effectiveness of magnetic compression anastomosis (MCA) for sutureless reconstruction after total gastrectomy in rats. 【Methods】 Twenty-four rats were randomly apportioned to two groups. Reconstruction was performed with MCA in the experimental group or hand-sewn in the control group, and the construction time was recorded. The animals were followed up for 30 days. The survival rate and complications were monitored. At each time point, the rats were euthanized to study the gross/histological morphology and mechanical strength of the anastomoses. 【Results】 The reconstruction time was (12.9±2.7)min in the experimental group and (23.8±4.1)min in the control group (P=0.036). In the experimental group, there was no anastomotic complication. Four control rats developed anastomotic leakage or hemorrhage, and all died within 4 postoperative days. Compared with the control group, burst pressure in the experimental group was similar. Both groups’ anastomoses had smooth gross appearance and histologically good alignment of tissue layers. 【Conclusion】 MCA is a safe and effective choice for reconstruction after total gastrectomy, with better postoperative outcomes than hand-sewn.

19.
Front Surg ; 10: 1335805, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38249312

RESUMO

Background and objectives: Magnetic anchor technique (MAT) is frequently used in laparoscopic cholecystectomy. However, there are few reports on its clinical application in China. In this study, we retrospectively analyzed the clinical application of MAT in laparoscopic cholecystectomy in China. Materials and methods: 25 patients (4 males, 21 females) who underwent laparoscopic cholecystectomy assisted by MAT at the First Affiliated Hospital of Xi'an Jiaotong University were enrolled from November 2020 to March 2021. Their records were retrospectively analyzed. The magnetic anchor device was independently designed and developed by the authors and consisted of the anchor magnet and magnetic grasping apparatus. Surgical time, intraoperative blood loss, intraoperative accidents, operator experience, postoperative incision pain score, postoperative complications, and other indicators were evaluated and analyzed. Results: All patients successfully underwent laparoscopic cholecystectomy, including 3 cases of MAT-assisted transumbilical single-port LC, 16 cases of MAT-assisted 2-port LC and 6 cases of conventional 3-port LC. The median operation time was 50 min (range 30-95 min); intraoperative bleeding was less than 30 ml. The median score of surgical incision on day 1 and 3 after the operation was 3 (range 1-4) and 1 (range 1-3), respectively. All patients had no intraoperative bile duct injury, vascular injury, postoperative bleeding, bile leakage, biliary stricture and other complications. No adverse events (such as injury to adjacent organs or failure of the magnetic anchor device) occurred either during or after the operation. Conclusions: The MAT-assisted laparoscopic cholecystectomy appears to be safe, feasible and effective and exhibits unique assistance in transumbilical single-port laparoscopic cholecystectomy.

20.
Surg Endosc ; 36(11): 8170-8177, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35501603

RESUMO

BACKGROUND: Being one of the core techniques of magnetic surgery, magnetic compression technique (MCT) has been used for digestive tract anastomosis reconstruction in experimental studies. This study verified the feasibility of gastroenteric anastomosis through natural orifice using MCT in rats. METHODS: The parent and daughter magnets were designed and manufactured for oral and anal insertion in 20 Sprague-Dawley rats. After anesthesia, the parent magnet was inserted into the colon spleen area through the anus, and the daughter magnet was inserted into the stomach through the mouth. Then the two magnets were positioned to attract each other and bind together. The position of the two magnets was monitored using X-ray. The time required for the formation of the anastomosis and expulsion of the magnets were recorded. 2 weeks later, the animal was sacrificed and the anastomotic specimen was obtained which was observed under naked eye and microscope. RESULTS: The gastroenteric anastomosis was successfully performed via natural orifices in 18 out of 20 rats. The mean time to construct the anastomosis was 3.78 ± 0.88 min. X-ray examination showed that the magnets were in the appropriate position in 17 rats. The magnets were excreted in 9.47 ± 1.62 days after surgery. The gross and microscopic examination of the specimen showed that the anastomoses were patent and the mucosa at the anastomotic was smooth. The mean bursting pressure of the anastomosis was 136.94 ± 6.79 mmHg. CONCLUSION: It is feasible to perform gastroenteric anastomosis through natural orifices by MCT.


Assuntos
Magnetismo , Imãs , Ratos , Animais , Ratos Sprague-Dawley , Anastomose Cirúrgica/métodos , Fenômenos Magnéticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...