J Shanghai Jiaotong Univ Sci ; 28(3): 348-359, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36846269

RESUMO

To reduce the risk of infection in medical personnel working in infectious-disease areas, we proposed a hyper-redundant mobile medical manipulator (HRMMM) to perform contact tasks in place of healthcare workers. A kinematics-based tracking algorithm was designed to obtain highly accurate pose tracking. A kinematic model of the HRMMM was established and its global Jacobian matrix was deduced. An expression of the tracking error based on the Rodrigues rotation formula was designed, and the relationship between tracking errors and gripper velocities was derived to ensure accurate object tracking. Considering the input constraints of the physical system, a joint-constraint model of the HRMMM was established, and the variable-substitution method was used to transform asymmetric constraints to symmetric constraints. All constraints were normalized by dividing by their maximum values. A hybrid controller based on pseudo-inverse (PI) and quadratic programming (QP) was designed to satisfy the real-time motion-control requirements in medical events. The PI method was used when there was no input saturation, and the QP method was used when saturation occurred. A quadratic performance index was designed to ensure smooth switching between PI and QP. The simulation results showed that the HRMMM could approach the target pose with a smooth motion trajectory, while meeting different types of input constraints.

2.
Zhongguo Zhen Jiu ; 41(2): 221-4, 2021 Feb 12.
Artigo em Chinês | MEDLINE | ID: mdl-33788475

RESUMO

In view of the limitations of the existing moxibustion instruments, i.e. possible accidental injury when using moxibustion instruments, the negative effects of products from moxibustion instruments on treatment efficacy and health of medical staff and patients, a moxibustion instrument with multi-jointed manipulator is designed. This moxibustion instrument could accurately control the temperature, maintain a safe moxibustion distance, automatically process the burning ashes of moxa and selectively handle moxa smoke. The experimental results shows that this instrument could maintain the constant temperature of target acupoint, reduce the risk of empyrosis, and reasonably deal with the products of moxibustion. The purification rate of moxa smoke is 44.9%, which not only ensures the therapeutic effect of moxa smoke, but also reduces the negative effects of high-concentration moxa smoke on the health of medical staff and patients.


Assuntos
Moxibustão , Pontos de Acupuntura , Humanos , Fumaça/análise , Temperatura
3.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-877573

RESUMO

In view of the limitations of the existing moxibustion instruments, i.e. possible accidental injury when using moxibustion instruments, the negative effects of products from moxibustion instruments on treatment efficacy and health of medical staff and patients, a moxibustion instrument with multi-jointed manipulator is designed. This moxibustion instrument could accurately control the temperature, maintain a safe moxibustion distance, automatically process the burning ashes of moxa and selectively handle moxa smoke. The experimental results shows that this instrument could maintain the constant temperature of target acupoint, reduce the risk of empyrosis, and reasonably deal with the products of moxibustion. The purification rate of moxa smoke is 44.9%, which not only ensures the therapeutic effect of moxa smoke, but also reduces the negative effects of high-concentration moxa smoke on the health of medical staff and patients.


Assuntos
Humanos , Pontos de Acupuntura , Moxibustão , Fumaça/análise , Temperatura