Resultados 1 - 20 de 52
Filtrar
1.
Math Biosci Eng ; 21(5): 5947-5971, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38872565

RESUMO

The technology of robot-assisted prostate seed implantation has developed rapidly. However, during the process, there are some problems to be solved, such as non-intuitive visualization effects and complicated robot control. To improve the intelligence and visualization of the operation process, a voice control technology of prostate seed implantation robot in augmented reality environment was proposed. Initially, the MRI image of the prostate was denoised and segmented. The three-dimensional model of prostate and its surrounding tissues was reconstructed by surface rendering technology. Combined with holographic application program, the augmented reality system of prostate seed implantation was built. An improved singular value decomposition three-dimensional registration algorithm based on iterative closest point was proposed, and the results of three-dimensional registration experiments verified that the algorithm could effectively improve the three-dimensional registration accuracy. A fusion algorithm based on spectral subtraction and BP neural network was proposed. The experimental results showed that the average delay of the fusion algorithm was 1.314 s, and the overall response time of the integrated system was 1.5 s. The fusion algorithm could effectively improve the reliability of the voice control system, and the integrated system could meet the responsiveness requirements of prostate seed implantation.


Assuntos
Algoritmos , Realidade Aumentada , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Próstata , Neoplasias da Próstata , Robótica , Humanos , Masculino , Robótica/instrumentação , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Próstata/diagnóstico por imagem , Imageamento Tridimensional , Voz , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Holografia/métodos , Holografia/instrumentação , Braquiterapia/instrumentação , Reprodutibilidade dos Testes
2.
Soft Robot ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38813669

RESUMO

Articular cartilage defects are among the most common orthopedic diseases, which seriously affect patients' health and daily activities, without prompt treatment. The repair biocarrier-based treatment has shown great promise. Total joint injection and open surgery are two main methods to deliver functional repair biocarriers into the knee joint. However, the exhibited drawbacks of these methods hinder their utility. The repair effect of total joint injection is unstable due to the low targeting rate of the repair biocarriers, whereas open surgery causes serious trauma to patients, thereby prolonging the postoperative healing time. In this study, we develop a magnetic soft catheter robot (MSCR) system to perform precise in situ repair of articular cartilage defects with minimal incision. The MSCR processes a size of millimeters, allowing it to enter the joint cavity through a tiny skin incision to reduce postoperative trauma. Meanwhile, a hybrid control strategy combining neural network and visual servo is applied to sequentially complete the coarse and fine positioning of the MSCR on the cartilage defect sites. After reaching the target, the photosensitive hydrogel is injected and anchored into the defect sites through the MSCR, ultimately completing the in situ cartilage repair. The in vitro and ex vivo experiments were conducted on a 3D printed human femur model and an isolated porcine femur, respectively, to demonstrate the potential of our system for the articular cartilage repair.

3.
Ann Biomed Eng ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634953

RESUMO

MR-guided microwave ablation (MWA) has proven effective in treating hepatocellular carcinoma (HCC) with small-sized tumors, but the state-of-the-art technique suffers from sub-optimal workflow due to the limited accuracy provided by the manual needle insertions. This paper presents a compact body-mounted MR-conditional robot that can operate in closed-bore MR scanners for accurate needle guidance. The robotic platform consists of two stacked Cartesian XY stages, each with two degrees of freedom, that facilitate needle insertion pose control. The robot is actuated using 3D-printed pneumatic turbines with MR-conditional bevel gear transmission systems. Pneumatic valves and control mechatronics are located inside the MRI control room and are connected to the robot with pneumatic transmission lines and optical fibers. Free-space experiments indicated robot-assisted needle insertion error of 2.6 ± 1.3 mm at an insertion depth of 80 mm. The MR-guided phantom studies were conducted to verify the MR-conditionality and targeting performance of the robot. Future work will focus on the system optimization and validations in animal trials.

4.
Int J Rob Res ; 42(10): 798-826, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37905207

RESUMO

Medical steerable needles can follow 3D curvilinear trajectories to avoid anatomical obstacles and reach clinically significant targets inside the human body. Automating steerable needle procedures can enable physicians and patients to harness the full potential of steerable needles by maximally leveraging their steerability to safely and accurately reach targets for medical procedures such as biopsies. For the automation of medical procedures to be clinically accepted, it is critical from a patient care, safety, and regulatory perspective to certify the correctness and effectiveness of the planning algorithms involved in procedure automation. In this paper, we take an important step toward creating a certifiable optimal planner for steerable needles. We present an efficient, resolution-complete motion planner for steerable needles based on a novel adaptation of multi-resolution planning. This is the first motion planner for steerable needles that guarantees to compute in finite time an obstacle-avoiding plan (or notify the user that no such plan exists), under clinically appropriate assumptions. Based on this planner, we then develop the first resolution-optimal motion planner for steerable needles that further provides theoretical guarantees on the quality of the computed motion plan, that is, global optimality, in finite time. Compared to state-of-the-art steerable needle motion planners, we demonstrate with clinically realistic simulations that our planners not only provide theoretical guarantees but also have higher success rates, have lower computation times, and result in higher quality plans.

5.
Math Biosci Eng ; 20(8): 15135-15166, 2023 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-37679175

RESUMO

At present, the incidence of prostate cancer (PCa) in men is increasing year by year. So, the early diagnosis of PCa is of great significance. Transrectal ultrasonography (TRUS)-guided biopsy is a common method for diagnosing PCa. The biopsy process is performed manually by urologists but the diagnostic rate is only 20%-30% and its reliability and accuracy can no longer meet clinical needs. The image-guided prostate biopsy robot has the advantages of a high degree of automation, does not rely on the skills and experience of operators, reduces the work intensity and operation time of urologists and so on. Capable of delivering biopsy needles to pre-defined biopsy locations with minimal needle placement errors, it makes up for the shortcomings of traditional free-hand biopsy and improves the reliability and accuracy of biopsy. The integration of medical imaging technology and the robotic system is an important means for accurate tumor location, biopsy puncture path planning and visualization. This paper mainly reviews image-guided prostate biopsy robots. According to the existing literature, guidance modalities are divided into magnetic resonance imaging (MRI), ultrasound (US) and fusion image. First, the robot structure research by different guided methods is the main line and the actuators and material research of these guided modalities is the auxiliary line to introduce and compare. Second, the robot image-guided localization technology is discussed. Finally, the image-guided prostate biopsy robot is summarized and suggestions for future development are provided.


Assuntos
Neoplasias da Próstata , Robótica , Masculino , Humanos , Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Biópsia , Neoplasias da Próstata/diagnóstico por imagem
6.
Micromachines (Basel) ; 14(6)2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37374695

RESUMO

With the advancement of intelligent medical robot technology, machine touch utilizing flexible sensors has emerged as a prominent research area. In this study, a flexible resistive pressure sensor was designed incorporating a microcrack structure with air pores and a composite conductive mechanism of silver/carbon. The aim was to achieve enhanced stability and sensitivity with the inclusion of macro through-holes (1-3 mm) to expand the sensitive range. This technology solution was specifically applied to the machine touch system of the B-ultrasound robot. Through meticulous experimentation, it was determined that the optimal approach involved uniformly blending ecoflex and nano carbon powder at a mass ratio of 5:1, and subsequently combining the mixture with an ethanol solution of silver nanowires (AgNWs) at a mass ratio of 6:1. This combination of components resulted in the fabrication of a pressure sensor with optimal performance. Under the pressure testing condition of 5 kPa, a comparison of the resistance change rate was conducted among samples using the optimal formulation from the three processes. It was evident that the sample of ecoflex-C-AgNWs/ethanol solution exhibited the highest sensitivity. Its sensitivity was increased by 19.5% compared to the sample (ecoflex-C) and by 11.3% compared to the sample (ecoflex-C-ethanol). The sample (ecoflex-C-AgNWs/ethanol solution), which only incorporated internal air pore microcracks without through-holes, exhibited sensitive response to pressures below 5 N. However, with the addition of through-holes, the measurement range of its sensitive response increased to 20 N, representing a 400% increase in the measurement range.

7.
Front Med Technol ; 5: 1195929, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37138725
8.
Sensors (Basel) ; 23(7)2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-37050814

RESUMO

In medical and surgical scenarios, the trajectory planning of a collaborative robot arm is a difficult problem. The artificial potential field (APF) algorithm is a classic method for robot trajectory planning, which has the characteristics of good real-time performance and low computing consumption. There are many variants of the APF algorithm, among which the most widely used variants is the velocity potential field (VPF) algorithm. However, the traditional VPF algorithm has inherent defects and problems, such as easily falling into local minimum, being unable to reach the target, poor dynamic obstacle avoidance ability, and safety and efficiency problems. Therefore, this work presents the improved velocity potential field (IVPF) algorithm, which considers direction factors, obstacle velocity factor, and tangential velocity. When encountering dynamic obstacles, the IVPF algorithm can avoid obstacles better to ensure the safety of both the human and robot arm. The IVPF algorithm also does not easily fall into a local problem when encountering different obstacles. The experiments informed the RRT* algorithm, VPF algorithm, and IVPF algorithm for comparison. Compared with the informed RRT* and VPF algorithm, the result of experiments indicate that the performances of the IVPF algorithm have significant improvements when dealing with different obstacles. The main aim of this paper is to provide a safe and efficient path planning algorithm for the robot arm in the medical field. The proposed algorithm can ensure the safety of both the human and the robot arm when the medical and surgical robot arm is working, and enables the robot arm to cope with emergencies and perform tasks better. The application of the proposed algorithm could make the collaborative robots work in a flexible and safe condition, which could open up new opportunities for the future development of medical and surgical scenarios.

9.
Zhongguo Zhen Jiu ; 43(4): 463-8, 2023 Apr 12.
Artigo em Chinês | MEDLINE | ID: mdl-37068825

RESUMO

The difficulties such as how to accurately locate acupoints and safely insert needles are presented in acupuncture robot. The puncture robot with high technological similarity to acupuncture robot is getting mature, and a large number of human trials and animal experiments have been conducted for the development of puncture robot. Through comparing the similarities and differences between puncture robot and acupuncture robot in the aspects of through-skin puncture, needle insertion and needle removal, the valuable technology of puncture robot is analyzed for the development of acupuncture robot, and the crucial direction of technology migration is determined. ①Integrating the mechanical feedback and medical imaging technology and utilizing the multi-modal perception to achieve the safety of acupuncture operation. ②Emphasizing the integration of the existing designs of chest puncture robot to realize the acupuncture operation with inhalation and exhalation involved. ③Focusing on the development of relevant technology of automatic needle removal through conducting the actual scenario of treatment with acupuncture robot in patients under non-anaesthetic condition.


Assuntos
Terapia por Acupuntura , Acupuntura , Robótica , Animais , Humanos , Estudos de Viabilidade , Punções , Agulhas
10.
Sensors (Basel) ; 23(6)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36991684

RESUMO

Our work introduces a new robotic solution named CochleRob, which is used for the administration of super-paramagnetic antiparticles as drug carriers into the human cochlea for the treatment of hearing loss caused by damaged cochlea. This novel robot architecture presents two key contributions. First, CochleRob has been designed to meet specifications pertaining to ear anatomy, including workspace, degrees of freedom, compactness, rigidity, and accuracy. The first objective was to develop a safer mathod to administer drugs to the cochlea without the need for catheter or CI insertion. Secondly, we aimed at developing and validating the mathemathical models, including forward, inverse, and dynamic models, to support the robot function. Our work provides a promising solution for drug administration into the inner ear.


Assuntos
Implante Coclear , Robótica , Humanos , Cóclea/cirurgia , Portadores de Fármacos , Fenômenos Magnéticos
11.
Sensors (Basel) ; 23(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36850859

RESUMO

For patients who are often embarrassed and uncomfortable when exposing their breasts and having them touched by physicians of different genders during auscultation, we are developing a robotic system that performs auscultation over clothing. As the technical issue, the sound obtained through the clothing is often attenuated. This study aims to investigate clothing-induced acoustic attenuation and develop a suppression method for it. Because the attenuation is due to the loss of energy as sound propagates through a medium with viscosity, we hypothesized that the attenuation is improved by compressing clothing and shortening the sound propagation distance. Then, the amplitude spectrum of the heart sound was obtained over clothes of different thicknesses and materials in a phantom study and human trial at varying contact forces with a developed passive-actuated end-effector. Our results demonstrate the feasibility of the attenuation suppression method by applying an optimum contact force, which varied according to the clothing condition. In the phantom experiments, the attenuation rate was improved maximumly by 48% when applying the optimal contact force (1 N). In human trials, the attenuation rate was under the acceptable attenuation (40%) when applying the optimal contact force in all combinations in each subject. The proposed method promises the potential of robotic auscultation toward eliminating gender bias.


Assuntos
Procedimentos Cirúrgicos Robóticos , Masculino , Humanos , Feminino , Sexismo , Acústica , Auscultação , Vestuário
12.
Int J Med Robot ; 19(1): e2461, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36097703

RESUMO

BACKGROUND: Since most developed countries are facing an increase in the number of patients per healthcare worker due to a declining birth rate and an ageing population, relatively simple and safe diagnosis tasks may need to be performed using robotics and automation technologies, without specialists and hospitals. This study presents an automated robotic platform for remote auscultation, which is a highly cost-effective screening tool for detecting abnormal clinical signs. METHOD: The developed robotic platform is composed of a 6-degree-of-freedom cooperative robotic arm, LiDAR camera, and a spring-based mechanism holding an electric stethoscope. The platform enables autonomous stethoscope positioning based on external body information acquired using the LiDAR camera-based multi-way registration; the platform also ensures safe and flexible contact, maintaining the contact force within a certain range through the passive-actuated mechanism. RESULTS: Our preliminary results confirm that the robotic platform enables estimation of the landing positions required for cardiac examinations based on the depth and landmark information of the body surface. It also handles the stethoscope while maintaining the contact force without relying on the push-in displacement by the robotic arm. CONCLUSION: The developed robotic platform enables the estimation of the landing positions and handling the stethoscope while maintaining the contact force, which promises the potential of automatic remote auscultation.


Assuntos
Robótica , Humanos , Auscultação/métodos , Automação , Pessoal de Saúde
13.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-980745

RESUMO

The difficulties such as how to accurately locate acupoints and safely insert needles are presented in acupuncture robot. The puncture robot with high technological similarity to acupuncture robot is getting mature, and a large number of human trials and animal experiments have been conducted for the development of puncture robot. Through comparing the similarities and differences between puncture robot and acupuncture robot in the aspects of through-skin puncture, needle insertion and needle removal, the valuable technology of puncture robot is analyzed for the development of acupuncture robot, and the crucial direction of technology migration is determined. ①Integrating the mechanical feedback and medical imaging technology and utilizing the multi-modal perception to achieve the safety of acupuncture operation. ②Emphasizing the integration of the existing designs of chest puncture robot to realize the acupuncture operation with inhalation and exhalation involved. ③Focusing on the development of relevant technology of automatic needle removal through conducting the actual scenario of treatment with acupuncture robot in patients under non-anaesthetic condition.


Assuntos
Animais , Humanos , Robótica , Estudos de Viabilidade , Terapia por Acupuntura , Punções , Acupuntura , Agulhas
14.
BMC Ophthalmol ; 22(1): 484, 2022 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-36510151

RESUMO

BACKGROUND: To design and develop a surgical robot capable of assisting subretinal injection. METHODS: A remote center of motion (RCM) mechanical design and a master-slave teleoperation were used to develop and manufacture the assisted subretinal surgery robot (RASR). Ten fresh isolated porcine eyes were divided into the Robot Manipulation (RM) group and Manual Manipulation (MM) group (5 eyes for each group), and subretinal injections were performed by the robot and manual manipulation methods, respectively. A preliminary verification of the robot was performed by comparing the advantages and disadvantages of the robot manipulation and manual manipulation by using optical coherent tomography (OCT), fundus photography, and video motion capture analysis after the surgery. RESULTS: Both the robot and the manual manipulation were able to perform subretinal injections with a 100% success rate. The OCT results showed that the average subretinal area was 1.548 mm2 and 1.461 mm2 in the RM and MM groups, respectively (P > 0.05). Meanwhile the volume of subretinal fluid obtained using the retinal map mode built in OCT was not statistically different between the RM and MM groups (P > 0.05). By analyzing the surgical video using Kinovea, a motion capture and analysis software, the results suggest that the mean tremor amplitude of the RM group was 0.3681 pixels (x direction), which was significantly reduced compared to 18.8779 pixels (x direction) in the MM group (P < 0.0001). CONCLUSION: Robot-assisted subretinal injection system (RASR) is able to finish subretinal injection surgery with better stability and less fatigue than manual manipulation.


Assuntos
Robótica , Animais , Suínos , Tomografia de Coerência Óptica/métodos , Líquido Sub-Retiniano , Retina/cirurgia , Software
15.
Front Robot AI ; 9: 906691, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35937618

RESUMO

The article discusses the design of a suspended lever mechanism with elastic elements, which is used as a safety device in a robotic system for the rehabilitation of the lower limbs. The article analyzes the existing mechanical structures of devices for rehabilitation, identifies the problems of operation, design, and safety systems and suggests a new design of the device. The process of reverse development of a lever mechanism scheme to ensure safety during rehabilitation of the lower limbs is presented. The design of the lever mechanism consists of movable levers connected by elastic elements. The device allows you to dampen the force during active rehabilitation. The power calculation of the lever mechanism in the rehabilitation system was carried out. The article addresses the issues present in the current mechanical designs with a brief discussion on the system architecture.

16.
Int J Med Robot ; 18(5): e2415, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35512295

RESUMO

BACKGROUND: The camera of an endoscope is fixed to the device, and the image rotates together with the endoscope. This can lead to visual confusion for the user and incorrect image reading. The problem also occurs with endoscopic robots. Using a master device with the same degrees of freedom as the endoscope to control an endoscopic robot causes visual-motor misorientation, making intuitive control difficult. METHODS: The roll misorientation between the image and master device handle was removed by measuring and correcting for the roll axis displacement of the master device. This enabled intuitive manipulation of the master device. The work speed and number of mistakes were experimentally measured with and without image correction. RESULTS: The tasks were completed significantly faster and more accurately with image orientation correction than without. CONCLUSIONS: The proposed method enables intuitive manipulation of the master device by correcting the image orientation in endoscopic robot control.


Assuntos
Robótica , Endoscópios , Endoscopia/métodos , Desenho de Equipamento , Humanos
17.
Sensors (Basel) ; 22(9)2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35590895

RESUMO

In recent decades, robot-assisted surgery has been proven superior at providing more accurate outcomes than the conventional one, particularly in minimally invasive procedures. However, there are still limitations to these kinds of surgical robots. Accurate bone drilling on the steep and hard surface of cortical bone is still challenging. The issues of slipping away from the target entry point on the bone surface and subsequently deviating from the desired path are still not completely solved. Therefore, in this paper, a force control is proposed to accompany the resolved motion rate controller in a handheld orthopedic robot system. The force control makes it possible to adjust the contact compliance of the drill to the bone surface. With the proper contact compliance, the drill can be prevented from deflecting in contact with the bone surface, and will eventually be directed to the target entry point. The experiments on test jig and vertebra phantom also show that the robot under the proposed contact compliance visual feedback control structure could produce better usability positioning accuracy under various contact disturbances than its counterpart.


Assuntos
Ortopedia , Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgia Assistida por Computador , Retroalimentação Sensorial , Robótica/métodos , Cirurgia Assistida por Computador/métodos
18.
Int J Med Robot ; 18(3): e2397, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35349215

RESUMO

BACKGROUND: Master devices exclusively used for endoscopes with position control are being developed as an isomorphic form of endoscopes. These master devices are difficult to intuitively operate because the movement direction of the endoscopic image and control handle do not match. METHODS: To solve this problem, a master device was developed. Its movement direction is compatible with that of the endoscopic image. It analyzes image movements according to flexible endoscopic ureteroscope movements for each degree of freedom. A driving testbed experiment was conducted that modelled the internal structure of a kidney. RESULTS: The time taken in the experiment was shorter when using the proposed master device than the existing isomorphic master device. The proposed device yielded fewer mistakes. CONCLUSIONS: It was confirmed the proposed device is effective in exclusive use for endoscopes because of its feasibility of position control and movement direction's coinciding with that of the endoscopic image.


Assuntos
Robótica , Endoscópios , Endoscopia/métodos , Desenho de Equipamento , Humanos
19.
Int J Med Robot ; 18(3): e2384, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35199451

RESUMO

BACKGROUND: Recent advancements in continuum robotics have accentuated developing efficient and stable controllers to handle shape deformation and compliance. The control of continuum robots (CRs) using physical sensors attached to the robot, particularly in confined spaces, is difficult due to their limited accuracy in three-dimensional deflections and challenging localisation. Therefore, using non-contact imaging sensors finds noticeable importance, particularly in medical scenarios. Accordingly, given the need for direct control of the robot tip and notable uncertainties in the kinematics and dynamics of CRs, many papers have focussed on the visual servoing (VS) of CRs in recent years. METHODS: The significance of this research towards safe human-robot interaction has fuelled our survey on the previous methods, current challenges, and future opportunities. RESULTS: Beginning with actuation modalities and modelling approaches, the paper investigates VS methods in medical and non-medical scenarios. CONCLUSIONS: Finally, challenges and prospects of VS for CRs are discussed, followed by concluding remarks.


Assuntos
Robótica , Fenômenos Biomecânicos , Diagnóstico por Imagem , Humanos , Robótica/métodos
20.
Bioengineering (Basel) ; 9(2)2022 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-35200411

RESUMO

To improve the accuracy of common intelligent algorithms when identifying the parameters of geometric error in medical robots, this paper proposes an improved beetle antennae search algorithm (RWSAVSBAS). We first establish a model for the kinematic error in medical robots, and then add the random wandering behavior of the wolf colony algorithm to the search process of the beetle antennae search algorithm to strengthen its capability for local search. Following this, we improve the global convergence ability of the beetle antennae search algorithm by using the simulated annealing algorithm. We compare the accuracy of end positioning of the proposed algorithm with the frog-jumping algorithm and the beetle antennae search algorithm with variable step length through simulations. The results show that the proposed algorithm has a higher accuracy of convergence, and can significantly improve the accuracy of end positioning of the medical robot.