Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.588
Filtrar
1.
J. optom. (Internet) ; 17(3): [100491], jul.-sept2024. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-231873

RESUMO

Background and objectives: The invention described herein is a prototype based on computer vision technology that measures depth perception and is intended for the early examination of stereopsis. Materials and methods: The prototype (software and hardware) is a depth perception measurement system that consists on: (a) a screen showing stereoscopic models with a guide point that the subject must point to; (b) a camera capturing the distance between the screen and the subject's finger; and (c) a unit for recording, processing and storing the captured measurements. For test validation, the reproducibility and reliability of the platform were calculated by comparing results with standard stereoscopic tests. A demographic study of depth perception by subgroup analysis is shown. Subjective comparison of the different tests was carried out by means of a satisfaction survey. Results: We included 94 subjects, 25 children and 69 adults, with a mean age of 34.2 ± 18.9 years; 36.2 % were men and 63.8 % were women. The DALE3D platform obtained good repeatability with an interclass correlation coefficient (ICC) between 0.94 and 0.87, and coefficient of variation (CV) between 0.1 and 0.26. Threshold determining optimal and suboptimal results was calculated for Randot and DALE3D test. Spearman's correlation coefficient, between thresholds was not statistically significant (p value > 0.05). The test was considered more visually appealing and easier to use by the participants (90 % maximum score). Conclusions: The DALE3D platform is a potentially useful tool for measuring depth perception with optimal reproducibility rates. Its innovative design makes it a more intuitive tool for children than current stereoscopic tests. Nevertheless, further studies will be needed to assess whether the depth perception measured by the DALE3D platform is a sufficiently reliable parameter to assess stereopsis.(AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto Jovem , Visão Binocular , Percepção de Profundidade , Visão Ocular , Testes Visuais
2.
Sci Rep ; 14(1): 15149, 2024 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956213

RESUMO

Dry eye syndrome (DES) is a tear film disorder caused by increased tear evaporation or decreased production. The heavy workload on the eye and the increased usage of digital screens may decrease blink frequency, leading to an increased evaporation rate and an upsurge in the incidence and severity of DES. This study aims to assess the severity of DES symptoms and the risk factors among university students. A cross-sectional study was conducted at Umm AlQura University to evaluate the severity of DES among students and explore its potential association with digital screen use. Validated questionnaires were used to assess the severity of DES and digital screen usage. The study included 457 participants, of which 13% had symptoms suggestive of severe DES. Furthermore, multiple risk factors had a significant association with the severity of DES, including gender, use of monitor filters, monitor and room brightness, and smoking habits. DES symptoms were prevalent among university students, particularly female students. Although there was no significant association with the duration of screen usage and collage distribution. Other factors however, such as the usage of screen monitors and the brightness of both the monitor and the room, were significantly associated with the severity of DES symptoms.


Assuntos
Síndromes do Olho Seco , Estudantes , Humanos , Síndromes do Olho Seco/epidemiologia , Síndromes do Olho Seco/diagnóstico , Feminino , Arábia Saudita/epidemiologia , Masculino , Estudos Transversais , Fatores de Risco , Universidades , Adulto Jovem , Adulto , Inquéritos e Questionários , Índice de Gravidade de Doença , Adolescente , Prevalência
3.
World J Diabetes ; 15(6): 1254-1262, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38983810

RESUMO

BACKGROUND: The FreeStyle Libre flash glucose monitoring (FGM) system entered the Chinese market in 2017 to complement the self-monitoring of blood glucose. Due to its increased usage in clinics, the number of studies investigating its accuracy has increased. However, its accuracy has not been investigated in highland popu-lations in China. AIM: To evaluate measurements recorded using the FreeStyle Libre FGM system compared with capillary blood glucose measured using the enzyme electrode method in patients with type 2 diabetes (T2D) who had migrated within 3 mo from highlands to plains. METHODS: Overall, 68 patients with T2D, selected from those who had recently migrated from highlands to plains (within 3 mo), were hospitalized at the Department of Endocrinology from August to October 2017 and underwent continuous glucose monitoring (CGM) with the FreeStyle Libre FGM system for 14 d. Throughout the study period, fingertip capillary blood glucose was measured daily using the enzyme electrode method (Super GL, China), and blood glucose levels were read from the scanning probe during fasting and 2 h after all three meals. Moreover, the time interval between reading the data from the scanning probe and collecting fingertip capillary blood was controlled to < 5 min. The accuracy of the FGM system was evaluated according to the CGM guidelines. Subsequently, the factors influencing the mean absolute relative difference (MARD) of this system were analyzed by a multiple linear regression method. RESULTS: Pearson's correlation analysis showed that the fingertip and scanned glucose levels were positively correlated (R = 0.86, P = 0.00). The aggregated MARD of scanned glucose was 14.28 ± 13.40%. Parker's error analysis showed that 99.30% of the data pairs were located in areas A and B. According to the probe wear time of the FreeStyle Libre FGM system, MARD1 d and MARD2-14 d were 16.55% and 14.35%, respectively (t = 1.23, P = 0.22). Multiple stepwise regression analysis showed that MARD did not correlate with blood glucose when the largest amplitude of glycemic excursion (LAGE) was < 5.80 mmol/L but negatively correlated with blood glucose when the LAGE was ≥ 5.80 mmol/L. CONCLUSION: The FreeStyle Libre FGM system has good accuracy in patients with T2D who had recently migrated from highlands to plains. This system might be ideal for avoiding the effects of high hematocrit on blood glucose monitoring in populations that recently migrated to plains. MARD is mainly influenced by glucose levels and fluctuations, and the accuracy of the system is higher when the blood glucose fluctuation is small. In case of higher blood glucose level fluctuations, deviation in the scanned glucose levels is the highest at extremely low blood glucose levels.

4.
Obes Pillars ; 11: 100115, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38983905

RESUMO

Introduction: This case study portrays an unusual case of treatment-induced neuropathy of diabetes (TIND) in a patient with uncontrolled type 2 diabetes (T2D) who achieved rapid improvement in glucose control primarily with dietary intervention. Initial presentation was 50-year-old white male with a long-standing history of obesity and a family history of T2D with a screening glucose level >500mg/dL by glucometer, HbA1c of 14.9%, and initial weight 213 lbs. Methods: The initial intervention included a low-carbohydrate diet, metformin, and a continuous glucose monitor (CGM). Semaglutide was added after seven days. Results: His glycemia was within the target range within three weeks. Four weeks after initiation of therapy, he developed TIND symptoms consisting of burning, tightness, and numbness of bilateral feet along with 10/10 pain. At three months, his HbA1c dropped to 6.9% and his weight to 195 lbs. Treatment of his TIND reduced his pain from 10/10 to 2/10. Conclusion: Whereas TIND is commonly associated with the use of insulin or sulfonylureas, this study adds evidence to the paucity of literature regarding TIND precipitated by dietary intervention.

5.
Transpl Infect Dis ; : e14328, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38980949

RESUMO

INTRODUCTION: Cytomegalovirus (CMV) infection is a major cause of transplantation-related morbidity and mortality. This study assessed the utility of the QuantiFERON monitor (QFM; Qiagen) for the prediction of early CMV infection and viral burden. METHODS: QuantiFERON-CMV (QF-CMV; Qiagen) and QFM were measured at the post-allogeneic hematopoietic stem cell transplantation (HSCT) week 4. CMV DNA was measured at every visit until post-HSCT week 24. The QFM cutoff specific to CMV infection was established. RESULT: At the post-HSCT week 4, the QFM cutoff predicting CMV infection was 86.95 IU/mL. While QF-CMV results at the post-HSCT week 4 were associated with high-level CMV infection (CMV DNA ≥ 5,000 IU/mL) but not with CMV infection (CMV DNA ≥ 500 IU/mL), QFM was associated with both CMV infection and high-level CMV infection. Both indeterminate QF-CMV and nonreactive QFM were associated with increased peak CMV DNA. CONCLUSION: Low QFM is a risk factor for CMV infection and increased CMV viral loads. QFM at post-HSCT week 4 can be utilized as an assay to predict the risk and burden of early CMV infection in HSCT recipients, in conjunction with other risk factors.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38963722

RESUMO

INTRODUCTION: Patients with Brugada syndrome (BrS) face an increased risk of ventricular arrhythmias and sudden cardiac death. Implantable cardiac monitors (ICMs) have emerged as effective tools for detecting arrhythmias in BrS. Technological advancements, including temperature sensors and improved subcutaneous electrocardiogram (subECG) signal quality, hold promise for further enhancing their utility in this population. METHODS AND RESULTS: We present a case of a 40-year-old man exhibiting a BrS type 2 pattern on 12-lead ECG, who underwent ICM insertion (BIOMONITOR IIIm, BIOTRONIK) due to drug-induced BrS type 1 pattern and a history of syncope, with a negative response to programmed ventricular stimulation. The device contains an integrated temperature sensor and can transmit daily vital data, such as mean heart rate and physical activity. Several months later, remote alerts indicated a temperature increase, along with transmitted subECGs suggesting a fever-induced BrS type 1 pattern. The patient was promptly advised to commence antipyretic therapy. Over the following days, remotely monitored parameters showed decreases in mean temperature, physical activity, and mean heart rate, without further recurrence of abnormal subECGs. CONCLUSION: ICMs offer valuable insights beyond arrhythmia detection in BrS. Early detection of fever using embedded temperature sensors may improve patient management, while continuous subECG morphological analysis has the potential to enhance risk stratification in BrS patients.

7.
J Endocr Soc ; 8(8): bvae125, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38974988

RESUMO

Context: The rise in continuous glucose monitor (CGM) use has been characterized by widening disparities between the least and most socially marginalized. Given access barriers, there is limited CGM patient experience information that is inclusive of those with type 2 diabetes mellitus from socially marginalized backgrounds. Objective: To understand the CGM usage experience in the primary care setting across a US Medicaid population with type 2 diabetes at federally qualified health centers. Methods: This qualitative study used semi-structured phone interviews with 28 English- or Spanish-speaking participants prescribed the CGM who were enrolled in a US Medicaid program that subsidized CGMs. Audio recordings of interviews were transcribed and analyzed by reflective thematic analysis. Results: Twenty-eight participants (75% female, median age 56 years with interquartile-range 48-60 years) were interviewed. Participants were from different racial/ethnic backgrounds: 21% non-Hispanic White, 57% Hispanic, and 18% non-Hispanic Black. Participants primarily spoke English (68%) or Spanish (32%), and 53% reported 9 or fewer years of formal education. We identified 6 major themes: initial expectations and overcoming initiation barriers, convenience and ease promote daily use, increased knowledge leads to improved self-management, collaboration with provider and clinical team, improved self-reported outcomes, and barriers and burdens are generally tolerated. Conclusion: CGM use was experienced as easy to understand and viewed as a tool for diabetes self-efficacy. Expanded CGM access for socially marginalized patients with type 2 diabetes can enhance diabetes self-management to help mitigate diabetes outcome disparities.

8.
Front Med (Lausanne) ; 11: 1396962, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38988353

RESUMO

Introduction: Blood pressure (BP) time-in-target-range (TTR) is an emerging predictor of cardiovascular risk. Conventional BP methods are fundamentally unable to provide an optimal assessment of TTR, using irregular measurements separated by lengthy intervals. We investigated the optimal duration and frequency for reliable, practical TTR assessment in clinical settings using continual monitoring. Methods: This retrospective study analyzed 2.3 million BP readings from 5,189 European home users (55 ± 11 years, 82% male, BMI 28.0 ± 5.8) using a cuffless BP monitor (Aktiia SA). Systolic BP (SBP) data over 15 consecutive days were assessed (29 ± 11 readings/subject/24-h; 434 + 132 readings/subject/15-day). Subjects were classified into risk-related TTR groups based on 15-day SBP data (24-h, target 90-125 mmHg; ≥6 daytime readings). Various measurement frequencies and durations (1-14 days; 24-h/daytime; 2, 4 or ≥ 6 readings/day) were compared to this reference. Two specific configurations paralleling ambulatory ("One-Day-24 h") and home ("One-Week-Daytime") BP monitoring were selected for detailed analysis. Results: The reference TTR classified 63.0% of the subjects as high risk, 19.0% intermediate, and 18.0% low. "One-Day-24 h" schedule inaccurately classified 26% of subjects compared to the reference TTR, and "One-Week-Daytime" schedule inaccurately classified 45%. Classification accuracy with both schedules was high for subjects with very low or very high reference TTR, but poor otherwise. Accuracy of ≥90% in TTR classification only occurred with 7 days of continual 24-h monitoring. Discussion: For the first time, with the benefit of a cuffless device that measures BP with sufficient frequency and duration, practical use of TTR is enabled as a potentially enhanced metric to manage hypertension.

9.
Adv Sci (Weinh) ; : e2403238, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38950170

RESUMO

Athletes are at high risk of dehydration, fatigue, and cardiac disorders due to extreme performance in often harsh environments. Despite advancements in sports training protocols, there is an urgent need for a non-invasive system capable of comprehensive health monitoring. Although a few existing wearables measure athlete's performance, they are limited by a single function, rigidity, bulkiness, and required straps and adhesives. Here, an all-in-one, multi-sensor integrated wearable system utilizing a set of nanomembrane soft sensors and electronics, enabling wireless, real-time, continuous monitoring of saliva osmolality, skin temperature, and heart functions is introduced. This system, using a soft patch and a sensor-integrated mouthguard, provides comprehensive monitoring of an athlete's hydration and physiological stress levels. A validation study in detecting real-time physiological levels shows the device's performance in capturing moments (400-500 s) of synchronized acute elevation in dehydration (350%) and physiological strain (175%) during field training sessions. Demonstration with a few human subjects highlights the system's capability to detect early signs of health abnormality, thus improving the healthcare of sports athletes.

10.
Heart Rhythm ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38969049

RESUMO

BACKGROUND: After a cryptogenic stroke, patients will often require prolonged cardiac monitoring; however, the subset of patients who would benefit from long-term rhythm monitoring is not clearly defined. OBJECTIVE: Using significant predictors of AF using age, sex, comorbidities, baseline 12-lead electrocardiogram, short term rhythm monitoring and echocardiogram data, we created a risk score and compared it to previously published risk scores. METHODS: Patients admitted to Montefiore Medical Center between May 2017 and June 2022 with a primary diagnosis of cryptogenic stroke or TIA who underwent long-term rhythm monitoring with an implantable cardiac monitor were retrospectively analyzed. RESULTS: Variables positively associated with a diagnosis of clinically significant atrial fibrillation include age (p < 0.001), race (p = 0.022), diabetes status (p = 0.026), and COPD status (p = 0.012), the presence of atrial runs (p = 0.003), the number of atrial runs per 24 hours (p < 0.001), the total number of atrial run beats per 24 hours (p < 0.001) and the number of beats in the longest atrial run (p < 0.001), LA enlargement (p = 0.007) and at least mild mitral regurgitation (p = 0.009). We created a risk stratification score for our population, termed the "ACL score." The ACL score demonstrated superiority to the CHA2DS2-VASc score and comparability to the C2HEST score for predicting device-detected AF. CONCLUSION: The ACL score enables clinicians to better predict which patients are more likely to be diagnosed with device-detected AF after a cryptogenic stroke.

12.
Cureus ; 16(5): e60741, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38903382

RESUMO

Insertable cardiac monitor (ICM), used for long-term heart rhythm monitoring, often experiences diagnostic challenges such as T-wave oversensing, leading to false positives. This case report presents a novel approach to rectifying T-wave oversensing in ICM implantations. In this case, we are sharing a 38-year-old female with recurrent syncopal episodes who underwent ICM implantation (LUX-Dx™, ICM-Boston Scientific, Marlborough, United States). Post-implantation, T-wave oversensing was detected. Instead of the usual readjustment or reinsertion, we employed a non-invasive method of repositioning the ICM at a 45-degree angle toward the right side of the heart through the existing incision. This effectively resolved the oversensing issue without complications or the need for a new incision. ICMs are vital in linking symptoms to arrhythmias, especially in cases where standard diagnostic tools fall short. Despite their utility, ICMs are susceptible to T-wave oversensing due to subcutaneous placement. Our case demonstrates a successful alternative approach to address this, enhancing ICM's diagnostic accuracy without invasive procedures. This case highlights the potential of repositioning ICMs as a simple, non-invasive solution to overcome T-wave oversensing issues. It calls for further research and discussion within the medical community to explore its wider applicability, thereby improving ICM efficacy in clinical practice. The patient experienced no complications following the procedure during the three-month visit with appropriate sensing, validating this approach as a feasible option in similar cases.

13.
J Clin Med ; 13(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38892946

RESUMO

Atrial fibrillation (AF) carries a stroke risk, often necessitating anticoagulation, especially in patients with risk factors. With the advent of implantable and wearable heart monitors, episodes of short bouts of atrial arrhythmias called atrial high-rate episodes (AHREs) or subclinical AF (SCAF) are commonly identified. The necessity of anticoagulation in patients with SCAF is unclear. However, recent randomized controlled trials, the NOAH-AFNET 6 and ARTESIA, have offered insights into this matter. Furthermore, a study-level meta-analysis combining data from both these trials has provided more detailed information. Reviewing the information thus far, we can conclude that DOACs can result in a notable reduction in the risk of ischemic stroke and can potentially decrease the risk of debilitating stroke, albeit with an increased risk of major bleeding. Thus, informed, shared decision-making is essential, weighing the potential benefits of stroke prevention against the risk of major bleeding when considering anticoagulation in this patient population.

14.
Nanomaterials (Basel) ; 14(11)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38869588

RESUMO

Diabetes is a common disease that seriously endangers human health. Continuous glucose monitoring (CGM) is important for the prevention and treatment of diabetes. Glucose-sensing photonic nanochains (PNCs) have the advantages of naked-eye colorimetric readouts, short response time and noninvasive detection of diabetes, showing immense potential in CGM systems. However, the developed PNCs cannot disperse in physiological environment at the pH of 7.4 because of their poor hydrophilicity. In this study, we report a new kind of PNCs that can continuously and reversibly detect the concentration of glucose (Cg) in physiological environment at the pH of 7.4. Polyacrylic acid (PAA) added to the preparation of PNCs forms hydrogen bonds with polyvinylpyrrolidone (PVP) in Fe3O4@PVP colloidal nanoparticles and the hydrophilic monomer N-2-hydroxyethyl acrylamide (HEAAm), which increases the content of PHEAAm in the polymer shell of prepared PNCs. Moreover, 4-(2-acrylamidoethylcarbamoyl)-3-fluorophenylboronic acid (AFPBA), with a relatively low pKa value, is used as the glucose-sensing monomer to further improve the hydrophilicity and glucose-sensing performances of PNCs. The obtained Fe3O4@(PVP-PAA)@poly(AFPBA-co-HEAAm) PNCs disperse in artificial serum and change color from yellow-green to red when Cg increases from 3.9 mM to 11.4 mM, showing application potential for straightforward CGM.

15.
J Appl Clin Med Phys ; : e14435, 2024 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-38922754

RESUMO

PURPOSE: A higher minimum monitor unit (minMU) for pencil-beam scanning proton beams in intensity-modulated proton therapy is preferred for more efficient delivery. However, plan quality may be compromised when the minMU is too large. This study aimed to identify the optimal minMU (OminMU) to improve plan delivery efficiency while maintaining high plan quality. METHODS: We utilized clinical plans including six anatomic sites (brain, head and neck, breast, lung, abdomen, and prostate) from 23 patients previously treated with the Varian ProBeam system. The minMU of each plan was increased from the current clinical minMU of 1.1 to 3-24 MU depending on the daily prescribed dose (DPD). The dosimetric parameters of the plans were evaluated for consistency against a 1.1-minMU plan for target coverage as well as organs-at-risk dose sparing. DPD/minMU was defined as the ratio of DPD to minMU (cGy/MU) to find the OminMU by ensuring that dosimetric parameters did not differ by >1% compared to those of the 1.1-minMU plan. RESULTS: All plans up to 5 minMU showed no significant dose differences compared to the 1.1-minMU plan. Plan qualities remained acceptable when DPD/minMU ≥35 cGy/MU. This suggests that the 35 cGy/MU criterion can be used as the OminMU, which implies that 5 MU is the OminMU for a conventional fraction dose of 180 cGy. Treatment times were decreased by an average of 32% (max 56%, min 7%) and by an average of 1.6 min when the minMU was increased from 1.1 to OminMU. CONCLUSION: A clinical guideline for OminMU has been established. The minMU can be increased by 1 MU for every 35 cGy of DPD without compromising plan quality for most cases analyzed in this study. Significant treatment time reduction of up to 56% was observed when the suggested OminMU is used.

16.
Heart Rhythm ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38880203

RESUMO

BACKGROUND: It remains unclear what causes symptoms in patients with paroxysmal atrial fibrillation (AF). OBJECTIVE: This study aimed to correlate the magnitudes of the skin sympathetic nerve activity (SKNA) with symptoms in patients with AF. METHODS: We prospectively enrolled patients with symptomatic paroxysmal AF for ambulatory electrocardiogram and SKNA recording. Heart rhythms at time of symptoms were categorized as AF or normal sinus rhythm (NSR). Maximal and average SKNA (aSKNA) and heart rate (HR) were compared between symptomatic and asymptomatic AF and NSR episodes using mixed effects models to account for within-patient correlations. RESULTS: Among the 31 enrolled patients, 16 (52%) had at least one episode of AF, and 24 (77%) endorsed symptoms during the monitoring period. Compared with asymptomatic AF episodes, symptomatic AF episodes had higher maximal aSKNA (1.260 [IQR 1.114-1.723] µV vs. 1.108 [IQR 0.974-1.312] µV, p<0.001) and higher maximal HR (152±24 bpm vs. 132±19 bpm, p<0.001). Symptomatic NSR episodes were associated with higher maximal aSKNA (1.612 [IQR 1.287-2.027] µV vs. 1.332 [IQR 1.033-1.668] µV, p=0.001) and higher maximal HR (152±24 bpm vs. 105±16 bpm, p<0.001) than asymptomatic NSR episodes. Of the symptomatic episodes, 66 (73%) occurred during NSR and 24 (27%) during AF. All p-values were obtained from mixed effects models. CONCLUSION: Symptomatic episodes in patients with paroxysmal AF were more frequently associated with NSR than AF. Symptomatic AF and NSR episodes were associated with higher aSKNA than asymptomatic episodes. In patients with paroxysmal AF, symptoms correlate better with SKNA than heart rhythm.

17.
Diabet Med ; : e15369, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38925143

RESUMO

AIMS: Continuous glucose monitors (CGMs) have expanded their scope beyond indicated uses for diabetes management and are gaining traction among people not living with diabetes (PNLD). CGMs track in time glucose levels and are proposed as tools for the early detection of abnormal glucose and a potential solution for its normalisation through behavioural change, particularly, diet personalisation and motivation of physical activity. This becomes relevance given the growing incidence of metabolic conditions, such as type 2 diabetes mellitus (T2DM). Clinical guidelines, however, do not recommend CGMs in contexts outside type 1 diabetes (T1DM) or insulin-treated T2DM. Therefore, there is a visible disconnect between the indicated and real-world usage of these medical devices. While the commercial market for CGMs in PNLD is expanding rapidly, a comprehensive and evidence-based evaluation of the devices' utility in this population has not been done. Therefore, this review aims to formulate a working model for CGM utility in PNLD as proposed by the 'health and wellness' market that advertises and distributes it to these individuals. METHODS: We aim to critically analyse the available research addressing components of the working model, that is (1) detection of abnormal glucose; (2) behavioural change, and (3) metabolic health improvement. RESULTS: We find a lack of consistent and high-quality evidence to support the utility of CGMs for these purposes. We identify significantly under-reserved areas including clinical benchmarks and scoring procedures for CGM measures, device acceptability, and potential adverse effects of CGMs on eating habits in PNLD. We also raise concerns about the robustness of available CGM research. CONCLUSION: In the face of these research gaps, we urge for the commercial claims suggesting the utility of the device in PNLD to be labelled as misleading. We argue that there is a regulatory inadequacy that fuels 'off-label' CGM distribution and calls for the strengthening of post-market clinical follow-up oversight for CGMs. We hope this will help to avert the continued misinformation risk to PNLD and 'off-label' exacerbation of health disparities.

18.
Int J Cardiol ; : 132301, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38944347

RESUMO

AIMS: Guidelines recommend insertable cardiac monitor (ICM) in the early phases of the evaluation of unexplained syncope (US) syncope, when an arrhythmic etiology is suspected. We examined the diagnostic yield of the last generation ICM (LG-ICM) to establish the causes of US, by assessing in the clinical practice the incidence of: relevant arrhythmia diagnosis, syncope recurrences and CM-guided cardiac electronic device (CIED) implantation. We investigated also baseline patient characteristics associated to an increased risk of relevant arrhythmias and of syncope recurrence. METHODS: Data prospectively collected from consecutive patients receiving LG-ICM for investigation of US or presyncope in our institution between November 2020 and January 2023 were analyzed. RESULTS: A total of 109 patients (mean age 64.4 ±â€¯16.1 years, 40.4% women) with US or pre-syncope episodes underwent implantation of the LG-ICM. During a mean follow-up of 11.7 ±â€¯8.1 months, LG-ICM diagnostic yield was 42% . In particular, LG-ICM detected cardiac arrhythmias in 29 (27%) patients (in 6 out of them during a syncope recurrence) and to exclude the arrhythmic origin of the syncope in additional 19 (17%) patients. LG-ICM guided the implantation of a CIED in 16 (15%) US patients, due to the diagnosis of asystole or severe bradycardia. Age ≥ 65 years (p = 0.012) and atrial arrhythmia history (p = 0.004) are significant independent predictors of arrhythmic diagnoses performed by LG-ICM, while CAD is predictor of syncope recurrence (bordering on statistical significance, p = 0.056). CONCLUSIONS: The diagnostic yield of LG-ICM in US syncope is comparable to those of ILR and previous generation ICM. The advantages of LG-ICM should be sought in lower hospital workload necessary to manage ICM data. Age ≥ 65 years and atrial arrhythmia history are independent predictors of significant ICM-detected arrhythmias.

19.
J Funct Morphol Kinesiol ; 9(2)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38921640

RESUMO

The study assessed vastus lateralis oxygen desaturation kinetics (SmO2) in 32 male cyclists (16 Seniors, 16 Juniors) during a 30 s sprint, examining effects of age and performance. An incremental test was used to determine ventilatory thresholds (VT1, VT2) and maximal oxygen uptake (VO2kg), followed by a sprint test to evaluate anaerobic performance. Cyclists' performance phenotype was determined as the ratio of power at VT2 to 5 s peak sprint power. Juniors exhibited sprinter-like traits, excelling in all functional tests except for lactate levels post-sprint. SmO2 data showed no age-related or bilateral differences across participants. The combined mean response time (MRT) revealed stronger bilateral goodness of fit (R2 = 0.64) than individual time delay (TD) and time constant (τ). Higher VO2kg at VT2, peak power, and maximal uptake were linked to longer TD, while shorter TD correlated with higher lactate production and increased fatigue. Bilaterally averaged SmO2 kinetics distinguished between sprint and endurance athletes, indicating the potential to reflect the alactic anaerobic system's capacity and depletion. Age did not affect desaturation rates, but younger cyclists showed greater response amplitude, attributed to a higher initial baseline rather than maximal desaturation at the end of the exercise.

20.
Int J Biol Macromol ; : 133331, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38945706

RESUMO

The multifunctional active smart biomass film was prepared by incorporating chitosan-adsorbed laurate esterified starch curcumin Pickering emulsion into the starch film matrix, with nano-cellulose serving as reinforcing agents. The mechanical and functional properties of the film were studied, and the film was used to monitor the freshness of pork. The results demonstrated a relatively uniform distribution of curcumin and Pickering emulsion droplets within the film matrix. Furthermore, the thermal stability was minimally impacted by the introduction of curcumin Pickering emulsion, while the tensile strength and tensile strain of the film were increased, and both its hydrophobicity and antioxidant properties were improved. The free radical scavenging rate reached 56.01 %, with sustained high antioxidant capacity even after 8 days. Additionally, the presence of curcumin provided the film with pH indicating ability and delayed pork spoilage. Therefore, this work provides an attractive strategy for constructing green, active, and smart biomass packaging films for meat packaging applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...