Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 45(2): 280-284, 2023 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-37157076

RESUMO

Objective To explore the optimal parameters for virtual mono-energetic imaging of liver solid lesions. Methods A retrospective analysis was performed on 60 patients undergoing contrast-enhanced spectral CT of the abdomen.The iodine concentration values of hepatic arterial phase images and the CT values of different mono-energetic images were measured.The correlation coefficient and coefficient of variation were calculated. Results The average correlation coefficients between iodine concentrations and CT values of hepatic solid lesion images at 40,45,50,55,60,65,and 70 keV were 0.996,0.995,0.993,0.989,0.978,0.970,and 0.961,respectively.The correlation coefficients at 40(P=0.007),45(P=0.022),50 keV (P=0.035)were higher than that at 55 keV,and the correlation coefficients at 40 keV(P=0.134) and 45 keV(P=0.368) had no significant differences from that at 50 keV.The coefficients of variation of the CT values at 40,45,and 50 keV were 0.146,0.154,and 0.163,respectively. Conclusion The energy of 40 keV is optimal for virtual mono-energetic imaging of liver solid lesions in the late arterial phase,which is helpful for the diagnosis of liver diseases.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Abdome , Fígado/diagnóstico por imagem , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-981264

RESUMO

Objective To explore the optimal parameters for virtual mono-energetic imaging of liver solid lesions. Methods A retrospective analysis was performed on 60 patients undergoing contrast-enhanced spectral CT of the abdomen.The iodine concentration values of hepatic arterial phase images and the CT values of different mono-energetic images were measured.The correlation coefficient and coefficient of variation were calculated. Results The average correlation coefficients between iodine concentrations and CT values of hepatic solid lesion images at 40,45,50,55,60,65,and 70 keV were 0.996,0.995,0.993,0.989,0.978,0.970,and 0.961,respectively.The correlation coefficients at 40(P=0.007),45(P=0.022),50 keV (P=0.035)were higher than that at 55 keV,and the correlation coefficients at 40 keV(P=0.134) and 45 keV(P=0.368) had no significant differences from that at 50 keV.The coefficients of variation of the CT values at 40,45,and 50 keV were 0.146,0.154,and 0.163,respectively. Conclusion The energy of 40 keV is optimal for virtual mono-energetic imaging of liver solid lesions in the late arterial phase,which is helpful for the diagnosis of liver diseases.


Assuntos
Humanos , Tomografia Computadorizada por Raios X , Estudos Retrospectivos , Abdome , Iodo , Fígado/diagnóstico por imagem , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
3.
Quant Imaging Med Surg ; 10(7): 1515-1525, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32676369

RESUMO

BACKGROUND: This study aimed to evaluate the effectiveness of spectral computed tomography (CT) mono-energy imaging combined with metal artifact reduction software (MARs) for metal implant artifact reduction using a phantom. METHODS: A quantitative standard phantom with 9 cylinders was used to simulate the attenuation of the different tissues of the human body around the metal implant. Groups A and B were divided according to conventional CT scan mode and spectral CT scan mode. Three sets of reconstructed images, including 120 kVp-like + MARs images, mono-energy images (MonoE), and MonoE + MARs images, were generated after spectral CT scanning. High-attenuation artifacts and low-attenuation artifacts were observed around the coil in the images of groups A and B. The CT values (Hounsfield unit) and standard deviation (SD) values of the artifacts were measured, and the artifact index and hardening artifact removal rate were calculated. RESULTS: Compared to conventional poly-energy CT images, for high-attenuation and low-attenuation artifacts, the artifact indices of 120 kVp-like + MARs, MonoE, and MonoE + MARs images were all reduced significantly. The hardening artifact removal rates of the high-attenuation and low-attenuation artifacts of 120 kVp-like + MARs images were 82% and 92%, respectively. The hardening artifact removal rate of the high-attenuation and low-attenuation artifacts of MonoE and MonoE + MARs images increased with the mono-energy level. CONCLUSIONS: Spectral CT using the 120 kVp-like + MARs, 110-140 keV MonoE, and MonoE + MARs reconstruction methods can reduce metal implant artifacts in varying degrees. MonoE + MARs reconstruction was the best method for reducing metal artifacts.

4.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 42(6): 776-780, 2020 Dec 30.
Artigo em Chinês | MEDLINE | ID: mdl-33423725

RESUMO

Objective To identify the optimal mono-energetic enhanced spectral CT for renal cortex in cortical phase based on the iodine concentration. Methods Fifty patients with normal renal function received the abdominal enhanced spectral CT examination.The iodine concentration and CT values of the multiple mono-energetic spectral images were measured on renal cortex in cortical phase,and the correlation between the iodine concentration and the CT values and the coefficient of variation(CV)were analyzed. Results The correlation analysis demonstrated that the correlation coefficient was 0.994,0.994,0.993,0.987,0.976,0.960,and 0.938 between mono-energetic spectral CT images(40-100 keV with interval 10 keV,respectively)and iodine concentration(all P <0.001).The correlation coefficients of 40 keV,50 keV(P=0.007)and 60 keV(P=0.030)were significantly higher compared with that of 70 keV,and the correlation coefficients were not significantly among 40 keV,50 keV and 60 keV(P =0.590).The CV of renal cortex in cortical phase was 0.21,0.20,and 0.19 for 40 keV,50 keV,and 60 keV,respectively. Conclusion 60 keV is the optimal mono-energy for the enhanced spectral CT of the renal cortex in cortical phase.


Assuntos
Meios de Contraste , Iodo , Córtex Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador
5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-878677

RESUMO

Objective To identify the optimal mono-energetic enhanced spectral CT for renal cortex in cortical phase based on the iodine concentration. Methods Fifty patients with normal renal function received the abdominal enhanced spectral CT examination.The iodine concentration and CT values of the multiple mono-energetic spectral images were measured on renal cortex in cortical phase,and the correlation between the iodine concentration and the CT values and the coefficient of variation(CV)were analyzed. Results The correlation analysis demonstrated that the correlation coefficient was 0.994,0.994,0.993,0.987,0.976,0.960,and 0.938 between mono-energetic spectral CT images(40-100 keV with interval 10 keV,respectively)and iodine concentration(all


Assuntos
Humanos , Meios de Contraste , Iodo , Córtex Renal/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...