Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 477
Filtrar
1.
J Thorac Dis ; 16(6): 3722-3731, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38983146

RESUMO

Background: Sarcopenia has emerged as a comprehensive predictor of mortality in diseased populations. The aim of this study was to evaluate the prognostic and predictive value of psoas muscle thickness/height (PMTH) measurement in patients with acute type A aortic dissection (AAAD). Methods: A retrospective analysis of patients (from January 2020 to December 2020) who underwent AAAD surgery at our institution was conducted. PMTH, as a measure of sarcopenia, was measured by preoperative computed tomography. Patients were classified into two groups according to the cut-off value of PMTH. To balance potential bias, a 1:1 propensity score matching (PSM) with a caliper 0.05 was conducted. Results: PSM analysis created 68 pairs of patients. In short-term outcomes, a lower PMTH value was strongly correlated with higher in-hospital mortality and renal failure. Receiver operating characteristic (ROC) analysis suggested that sarcopenia had good predictive capabilities in in-hospital mortality, with the area under curve (AUC) of 0.81 [95% confidence interval (CI): 0.64-0.97]. During a median follow-up of 37 months, 24 (19.4%) patients died, including 16 in low PMTH group and 8 in high PMTH group. Kaplan-Meier analysis indicated the sarcopenia significantly affected long-term survival [log-rank P=0.02; hazard ratio (HR) 2.53 (95% CI: 1.13-5.66)]. Multivariable Cox regression analysis revealed that sarcopenia was an independent predictor for decreased survival [HR 2.73 (95% CI: 1.15-8.78)]. Conclusions: Sarcopenia defined from the PMTH may be a useful tool for predicting short- and long-term mortality in patients after AAAD surgery.

2.
Front Physiol ; 15: 1409702, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38948082

RESUMO

The purpose of this study was to compare acute responses between manual and automated blood flow restriction (BFR) systems. Methods: A total of 33 individuals completed this study. On visit 1, arterial occlusion pressure (AOP, mm Hg), cardiovascular responses, and discomfort (RPE-D) were measured with each BFR system at rest. On visit 2, unilateral bicep curls were completed [30% one-repetition maximum; 50% AOP] with one system per arm. Muscle thickness (MT, cm) and maximal force (N) were assessed before (pre), immediately (post-0), 5 min (post-5), and 10 min (post-10) post-exercise. Ratings of perceived exertion (RPE-E) and ratings of perceived discomfort (RPE-D) were assessed throughout the exercise. AOP and repetitions were compared with Bayesian paired t-tests. Other outcomes were compared with Bayesian RMANOVAs. BF10 represents the likelihood of the best model vs. the null. The results are presented as mean ± SD. Results: Supine cardiovascular responses and RPE-D were similar for manual and automated (all BF10 ≤ 0.2). Supine AOP for manual (157 ± 20) was higher than that of automated (142 ± 17; BF10 = 44496.0), but similar while standing (manual: 141 ± 17; automated: 141 ± 22; BF10 = 0.2). MT (time, BF10 = 6.047e + 40) increased from Pre (3.9 ± 0.7) to Post-0 (4.4 ± 0.8; BF10 = 2.969e + 28), with Post-0 higher than Post-5 (4.3 ± 0.8) and Post-10 (4.3 ± 0.8; both BF10 ≥ 275.2). Force (time, BF10 = 1.246e + 29) decreased from Pre (234.5 ± 79.2) to Post-0 (149.8 ± 52.3; BF10 = 2.720e + 22) and increased from Post-0 to Post-5 (193.3 ± 72.7; BF10 = 1.744e + 13), with Post-5 to Post-10 (194.0 ± 70.6; BF10 = 0.2) being similar. RPE-E increased over sets. RPE-D was lower for manual than automated. Repetitions per set were higher for manual (Set 1: 37 ± 18; Set 4: 9 ± 5) than automated (Set 1: 30 ± 7; Set 4: 7 ± 3; all BF10 ≥ 9.7). Conclusion: Under the same relative pressure, responses are mostly similar between BFR systems, although a manual system led to lower exercise discomfort and more repetitions.

3.
J Foot Ankle Res ; 17(3): e12035, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38970813

RESUMO

This study aimed to identify changes in the architecture and performance of the peri-ankle muscles in patients with chronic ankle instability (CAI) and investigate the relationship between them. In total, 17 subjects were evaluated retrospectively. Each subject underwent anthropometric and isokinetic test, and peroneus longus (PL) and brevis (PB), medial gastrocnemius (MGCM), and tibialis anterior (TA) ultrasound imaging were performed at rest and maximum voluntary contraction (MVC) conditions. Regarding muscle architectural variables, the pennation angle (PA) of the MGCM at rest and the PA of the TA, MGCM, and PL in MVC were significantly reduced on the injured side compared to the intact side. There were no significant differences in muscle thickness of PL, PB, MGCM, and TA observed between intact and injured side during both rest and MVC. Regarding muscle performance parameters, significant decreased were observed in the muscle strength for both limbs in all four directions under the two different conditions. A secondary finding was that the relative PA ratio of the TA showed moderate correlation with the relative dorsiflexion ratio at 30°/s. These findings can provide opportunities to better understand how injuries in patients with CAI may be related to changes in ankle and foot function.


Assuntos
Articulação do Tornozelo , Instabilidade Articular , Força Muscular , Músculo Esquelético , Ultrassonografia , Humanos , Instabilidade Articular/fisiopatologia , Instabilidade Articular/diagnóstico por imagem , Estudos Retrospectivos , Músculo Esquelético/fisiopatologia , Músculo Esquelético/diagnóstico por imagem , Masculino , Feminino , Estudos Transversais , Articulação do Tornozelo/fisiopatologia , Articulação do Tornozelo/diagnóstico por imagem , Adulto , Adulto Jovem , Força Muscular/fisiologia , Doença Crônica , Contração Muscular/fisiologia , Traumatismos do Tornozelo/fisiopatologia , Traumatismos do Tornozelo/diagnóstico por imagem
4.
Scand J Med Sci Sports ; 34(6): e14683, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38898582

RESUMO

Our previous study showed that daily six maximal eccentric contractions that were performed 5 days a week for 4 weeks increased maximal voluntary isometric (MVC-ISO), concentric (MVC-CON), and eccentric contraction (MVC-ECC) strength of the elbow flexors and muscle thickness of biceps brachii and brachialis (MT) by 8.3 ± 4.9%, 11.1 ± 7.4%, 13.5 ± 11.5%, and 10.6 ± 5.1%, respectively. In the present study, we tested the hypothesis that the muscle strength and MT would still increase when the training intensity was reduced to 2/3 or 1/3 of the peak MVC-ECC torque. Thirty-six healthy young (19-24 years) adults who had not performed resistance training were placed to three groups (n = 12/group): 2/3MVC or 1/3MVC that performed six eccentric contractions with 2/3 or 1/3 MVC-ECC load using a dumbbell 5 days a week for 4 weeks or control group that did not perform any training. Changes in the MVC-ISO, MVC-CON, MVC-ECC torque, and MT before and after the 4-week period were compared among the groups and with the group of the previous study in which six maximal eccentric contractions were performed 5 days a week for 4 weeks (MVC group; n = 12). The control and 1/3MVC groups showed no significant changes in any measures. Significant (p < 0.05) increases in MVC-ISO (10.3 ± 11.4%), MVC-CON (10.9 ± 9.5%), and MVC-ECC (9.3 ± 8.8%) torque and MT (10.1 ± 9.2%) were observed for the 2/3MVC group. These changes were not significantly different from those of the MVC group. These results suggest that the 2/3-intensity eccentric contractions with a dumbbell are as effective as maximal-intensity isokinetic eccentric contractions to induce muscle adaptations.


Assuntos
Contração Isométrica , Força Muscular , Músculo Esquelético , Torque , Humanos , Força Muscular/fisiologia , Adulto Jovem , Masculino , Músculo Esquelético/fisiologia , Feminino , Contração Isométrica/fisiologia , Treinamento Resistido/métodos , Contração Muscular/fisiologia , Cotovelo/fisiologia
5.
Clin Interv Aging ; 19: 993-1003, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38831963

RESUMO

Purpose: Muscle ultrasound has emerged as a promising method in the diagnostic work-up of sarcopenia. The objective of this scoping review was to explore the validity of muscle ultrasound against the latest sarcopenia definitions among older adults. Methods: We adhered to the PRISMA guidelines for scoping reviews. A systematic search of databases was performed by two independent reviewers. All articles comparing the performance of ultrasound to an internationally acknowledged sarcopenia definition among older adults (≥60 years) and published between 2019/01/01 (the year updated sarcopenia definitions were introduced) and 2023/11/15 were included. Data were extracted and collated by muscle and muscle parameters. Results: Out of 2290 articles screened, six studies comprising 24 validity tests among a total of 1619 older adults (mean age 74.1 years, 52.2% female) were included. The validity tests investigated the rectus femoris (n = 7), biceps brachii (n = 5), gastrocnemius medialis (n = 4), tibialis anterior (n = 4), soleus (n = 3), and rectus abdominis (n = 1). The parameter muscle thickness (MT) (n = 14) was most commonly measured. The latest European and Asian sarcopenia definitions (EWGSOP2, AWGS2) were applied as reference standards in four validity tests each. None of the studies used the Sarcopenia Definition and Outcome Consortium (SDOC) criteria. The highest area under the curve AUC (0.92, 95% confidence interval [CI] 0.89-0.94) was found for the muscle thickness of the rectus femoris muscle. Due to substantial heterogeneity among the studies, pooling of data using a meta-analytic approach was not feasible. Conclusion: Limited number of studies have examined the validity of muscle ultrasound for diagnosing sarcopenia based on recent definitions among older adults. Thereby, muscle thickness of the rectus femoris showed promising results regarding validity. Further studies are needed to investigate the validity of key muscles and to validate muscle ultrasound among older hospitalized patients.


Assuntos
Músculo Esquelético , Sarcopenia , Ultrassonografia , Humanos , Sarcopenia/diagnóstico por imagem , Idoso , Músculo Esquelético/diagnóstico por imagem , Feminino , Masculino , Reprodutibilidade dos Testes
6.
Front Physiol ; 15: 1382982, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38860113

RESUMO

Objectives: To compare the inter-rectus distance (IRD), rectus abdominis thickness (RAT), and stiffness in women during pregnancy and postpartum and identify the risk and protective factors affecting diastasis recti abdominis (DRA). Materials and methods: A total of 171 pregnant women who volunteered to participate in this study were recruited. Using an ultrasonographic diagnostic instrument with shear wave elastography function, IRD, RAT and the Young's modulus of the rectus abdominis muscles were measured at 12 weeks, 37 weeks of pregnancy, and 6 weeks postpartum. Results: The IRD at 37 weeks was significantly higher than that at 12 weeks and then decreased at 6 weeks postpartum, but it was still higher than that at 12 weeks (p < 0.001). RAT and Young's modulus decreased significantly at 37 weeks compared with those at 12 weeks and then recovered at 6 weeks postpartum, but they were lower than those at 12 weeks (p < 0.001). IRD at 12 weeks was significantly higher in multiparae than in primiparae (p < 0.001). Moreover, positive correlation between the RAT and Young's modulus of rectus abdominis muscles at 12 and 37 weeks of gestation and 6 weeks postpartum (p < 0.001) was observed. Multiple linear regression analysis showed that the regression equation was significant (f = 24.856, p < 001). Conclusion: Our study identified differences in IRD, thickness and stiffness of the rectus abdominis muscle between early and advanced pregnancy and the postpartum period. The risk and protective factors of DRA may guide pregnant women's protection and treatment.

7.
Sports Health ; : 19417381241257181, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38864295

RESUMO

BACKGROUND: Improving muscle quality to prevent and treat muscle dysfunction is critical. However, effective measures to improve muscle quality remain poorly understood. We investigated the effects of high- and low-velocity resistance training (RT) on muscle quality, mass, and function before and after an 8-week intervention. HYPOTHESIS: High-velocity RT would improve muscle quality more effectively than low-velocity RT. STUDY DESIGN: Randomized controlled trial. LEVEL OF EVIDENCE: Level 1. METHODS: A total of 33 healthy young women (23.1 ± 2.2 years) were assigned randomly to high-velocity (n = 16) or low-velocity (n = 17) groups. Both groups underwent concentric knee extension RT with a 60% 1-repetition maximum (1RM) load, performing 10 repetitions of 4 sets, 3 times per week for 8 weeks. The high-velocity group was instructed to complete each repetition as quickly as possible (mean repetition duration of 0.5 seconds), while the low-velocity group was required to execute each repetition in 3 seconds. Before and after the 8-week intervention, quadriceps femoris echo intensity (EI), muscle thickness (MT), isokinetic peak torque (60 and 300 deg/s), rate of velocity development (RVD) at 300 deg/s, and 1RM were assessed. Split-plot factorial design analysis of variance was used to compare the group × time interaction. RESULTS: A group×time interaction was observed for EI (P < 0.01). Only the high-velocity group showed a significant reduction in EI after the intervention. MT revealed a main effect of time (P < 0.01), with both groups significantly increasing MT. RVD showed a group × time interaction (P < 0.05), with significant increase only in the high-velocity group. Isokinetic peak torque and 1RM showed main effects of time (P < 0.01), with significant increases in both groups. CONCLUSION: High-velocity RT may be superior to low-velocity RT in enhancing muscle quality and RVD. CLINICAL RELEVANCE: These results emphasize the importance of RT velocity for muscle quality improvement.

8.
J Bodyw Mov Ther ; 39: 319-322, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38876645

RESUMO

OBJECTIVE: We aimed to verify the reliability of muscle thickness and luminance evaluation of the deep leg muscles using an ultrasound device. DESIGN: Cohort study. SETTING: Track and field, Participants: high school track and field long distance athletes (N = 10, female: 50.0%, age = 16.0 ± 2.8 years, BMI = 18.2 ± 2.3 kg/m2) PARTICIPANTS: This study included Japanese high school track and long-distance field athletes. MAIN OUTCOME MEASURES: The thickness and echo intensity of tibialis posterior, flexor digitorum longus, and soleus muscles in the posterior medial tibia were clarified. RESULTS: The echo intensity evaluation of the tibialis posterior muscle showed an additive error. CONCLUSION: The study suggested that the results could be clinically applied clinically, except for the evaluation of echo intensity of the posterior tibialis muscle.


Assuntos
Músculo Esquelético , Tíbia , Ultrassonografia , Humanos , Feminino , Ultrassonografia/métodos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Tíbia/diagnóstico por imagem , Adolescente , Masculino , Reprodutibilidade dos Testes , Atletismo/fisiologia , Atletas , Adulto Jovem , Estudos de Coortes
9.
J Bodyw Mov Ther ; 39: 423-430, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38876662

RESUMO

INTRODUCTION: Patellofemoral pain (PFP) patients often show an altered lower limb alignment during the single-leg squat (SLS). There is evidence that proximal and distal-to-the-knee muscle alterations can modify the lower limb alignment in PFP patients. However, we observed a lack of studies investigating the possible association between the thickness and strength of proximal and distal-to-the-knee muscles and lower limb alignment during SLS in women with PFP. Therefore, this study aimed to investigate the association between the thickness and strength of lower limb muscles and dynamic knee valgus (DKV) during SLS in women with PFP. METHODS: Cross-sectional study, where fifty-five women with PFP were submitted to the following evaluations: (1) muscle thickness (MT) of Gluteus Medius (GMed), Gluteus Maximus (GMax), Vastus Lateralis (VL), and Tibialis Anterior (TA); (2) isometric peak torque of hip abductors, hip external rotators, knee extensors, and foot inversors; and (3) DKV during SLS. RESULTS: There was a significant negative association between GMax's MT and DKV (r = -0.32; p = 0.01), and between TA's MT and DKV (r = -0.28; p = 0.03). No significant correlations were observed between isometric torques and DKV. Regression analysis found that GMax's MT explained 10% of the DKV's variance during SLS. DISCUSSION: Poor lower limb alignment during SLS is weakly associated with proximal and distal-to-the-knee muscle thicknesses, with no association with isometric torque in PFP women. CONCLUSION: Our results suggest that other factors besides strength and muscle thicknesses may explain and improve lower limb alignment in women with PFP.


Assuntos
Extremidade Inferior , Força Muscular , Músculo Esquelético , Síndrome da Dor Patelofemoral , Humanos , Feminino , Estudos Transversais , Adulto , Síndrome da Dor Patelofemoral/fisiopatologia , Músculo Esquelético/fisiopatologia , Músculo Esquelético/fisiologia , Força Muscular/fisiologia , Adulto Jovem , Extremidade Inferior/fisiopatologia , Extremidade Inferior/fisiologia , Torque , Articulação do Joelho/fisiopatologia , Articulação do Joelho/fisiologia
10.
J Bodyw Mov Ther ; 39: 67-72, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38876701

RESUMO

BACKGROUND: Dysfunctional patterns of the erector spinae (ES) and gluteus medius (GM) muscles often accompany episodes of low back pain (LBP). Rehabilitative ultrasound imaging (RUSI) has been used to measure ES and GM muscle thickness, however such measurements have not been compared in individuals with and without LBP. OBJECTIVES: To compare ES and GM muscle thickness and change in thickness utilizing RUSI in individuals with and without LBP. DESIGN: Cross-sectional comparison. METHODS: A volunteer sample of 60 adults with (n = 30) and without (n = 30) LBP was examined. Thickness measurements of the ES and GM at rest and during contraction were obtained by using RUSI during a single session. Statistical comparison was performed using ANCOVA. The demographic variable age was used as a covariate in the primary comparative analysis. RESULTS: Mean difference for age between groups was 5.4 years (95% CI: 1.85, 8.94, p = 0.004). Average ODI score was 32.33±6.58 and pain level of 5.39±0.73 over the last 24 h in the symptomatic group. There was a statistically significant difference in the percent thickness change in both the ES, mean difference = -3.46 (95% CI: -6.71, -0.21, p = 0.039) and GM, mean difference = -1.93 (95% CI: -3.85, -0.01, p = 0.049) muscles between groups. CONCLUSIONS: Individuals with LBP may have reduced percent thickness change of the ES and GM muscles when compared to asymptomatic individuals.


Assuntos
Dor Lombar , Músculo Esquelético , Ultrassonografia , Humanos , Dor Lombar/fisiopatologia , Masculino , Feminino , Estudos Transversais , Adulto , Pessoa de Meia-Idade , Músculo Esquelético/fisiopatologia , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Músculos Paraespinais/diagnóstico por imagem , Músculos Paraespinais/fisiologia , Músculos Paraespinais/fisiopatologia , Nádegas , Contração Muscular/fisiologia
11.
Sci Rep ; 14(1): 14522, 2024 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-38914688

RESUMO

The present study aimed to assess the effectiveness and functional adverse effects of a single and multiple injections of botulinum toxin A (BoNT-A) for masseter hypertrophy (MH). Twenty-six women complaining about lower third facial enlargement due to MH, received 75 U of BoNT-A (abobotulinum toxin) in each masseter muscles. After 3 months, patients were randomly assigned to receive a second treatment session of Saline Solution: (G1; n = 11) or BoNT-A: (G2; n = 12). Muscle thickness (ultrasound), electrical activity (electromyography; EMG), masticatory performance, and subjective perception of MH were evaluated. Follow-up was performed at 1, 3 and 6 months. Muscle thickness, EMG activity, and masticatory performance were analyzed using ANOVA two-way and Sidak test as post-hoc. Masticatory performance was analyzed by the Friedman's test and Mann-Whitney test. Regarding inter-groups comparisons, there was a significant decrease in the left masseter muscle thickness in the G2 group at the 6 month follow-up (p < 0.02). For EMG, significant differences were evident at the 6 month assessment, with higher masseter activity for G1 (p < 0.05). For masticatory performance, no significant differences were observed throughout the study (p > 0.05) and a higher improvement in subjective perception of MH was observed in the 1 month follow-up for G2 (p < 0.05). In conclusion, BoNT-A is effective for MH, however multiple injections cause functional adverse effects in masseter muscle.


Assuntos
Toxinas Botulínicas Tipo A , Eletromiografia , Hipertrofia , Músculo Masseter , Humanos , Músculo Masseter/efeitos dos fármacos , Músculo Masseter/patologia , Músculo Masseter/anormalidades , Feminino , Hipertrofia/tratamento farmacológico , Toxinas Botulínicas Tipo A/administração & dosagem , Toxinas Botulínicas Tipo A/uso terapêutico , Toxinas Botulínicas Tipo A/efeitos adversos , Adulto , Mastigação/efeitos dos fármacos , Pessoa de Meia-Idade , Resultado do Tratamento , Fármacos Neuromusculares/uso terapêutico , Fármacos Neuromusculares/administração & dosagem , Injeções Intramusculares
12.
Front Med (Lausanne) ; 11: 1333205, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38828232

RESUMO

Muscle ultrasound is a valuable non-invasive and cost-effective method in assessing muscle mass and structure, both of which are significant indicators for the development of sarcopenia and frailty in elderly individuals. Sarcopenia refers to the loss of muscle mass and strength that occurs with age, whereas frailty is a complex geriatric syndrome characterized by reduced physical function and an increased susceptibility to negative health outcomes. Both conditions are prevalent in older adults and are associated with higher risks of falls, disability, and mortality. By measuring muscle size and structure and several other ultrasound parameters, including muscle thickness, cross-sectional area, echogenicity (brightness in the ultrasound image), pennation angle, and fascicle length ultrasound can assist in identifying sarcopenia and frailty in older adults. In addition, ultrasound can be used to evaluate muscle function such as muscle contraction and stiffness, which may also be affected in sarcopenia and frailty. Therefore, muscle ultrasound could lead to better identification and tracking of sarcopenia and frailty. Such advancements could result in the implementation of earlier interventions to prevent or treat these conditions, resulting in an overall improvement in the health and quality of life of the elderly population. This narrative review describes the benefits and challenges when using ultra-sound for the evaluation of frailty and sarcopenia.

13.
Clin Oral Investig ; 28(5): 288, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722451

RESUMO

OBJECTIVES: Total tooth loss is common in the aging population resulting in insufficient chewing function with subsequent weakening of the masticatory muscles. The study aims to evaluate the changes in thicknesses of the masseter and anterior temporal muscle in edentulous patients following the reconstruction of implant-supported fixed prostheses and compare them with the dentate individuals. MATERIALS AND METHODS: The study was designed as a prospective, single-center, controlled clinical trial. A total of 60 participants were included in the present study. The patients were divided into two groups; Group I (Test Group): 30 edentulous patients who received implant-supported fixed prostheses, Group II (Control Group): 30 dentate individuals of an age and sex-matched group. Ultrasonography was used to measure the cross-sectional thickness of the left and right musculus masseter and anterior temporalis immediately after the cementation of the prosthetic rehabilitation (T1), on the 1st (T2) and 6th (T3) months after rehabilitation and at a single time point in the control group. RESULTS: The results showed that there were significant comparison differences in muscle thickness at the baseline measurements between groups while at the end of the 6th month, these differences were not significant. The muscle thicknesses of both the masseter and anterior temporalis muscles increased significantly at T2 and T3 compared to T1 in the test group. The asymmetry index between the left and right muscles in the test group and the asymmetry differences between groups also decreased significantly at the end of the 6th month. CONCLUSION: The implant-supported fixed prostheses significantly increase the thicknesses of the masseter and anterior temporal muscle together with a decrease in the asymmetry between the left and right muscles. At six months, implant-treated patients showed similar muscle thicknesses compared to dentate individuals. CLINICAL RELEVANCE: The findings suggest that implant-supported fixed prostheses can improve the masticatory function and facial symmetry of edentulous patients.


Assuntos
Prótese Dentária Fixada por Implante , Músculo Masseter , Boca Edêntula , Músculo Temporal , Ultrassonografia , Humanos , Masculino , Feminino , Estudos Prospectivos , Músculo Masseter/diagnóstico por imagem , Músculo Temporal/diagnóstico por imagem , Pessoa de Meia-Idade , Boca Edêntula/reabilitação , Boca Edêntula/diagnóstico por imagem , Idoso , Resultado do Tratamento
14.
Top Stroke Rehabil ; : 1-13, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780025

RESUMO

BACKGROUND: The effect of core stabilization exercises (CSE) alone, or in combination with neuromuscular electrical stimulation (NMES) and Kinesio taping (KT) on lung function, respiratory muscle strength, and thickness in patients with stroke is not fully known. OBJECTIVE: To compare the efficacy of NMES and KT applied with CSE on lung functions, respiratory muscle strength, and thickness in patients with stroke. METHODS: A total of 45 stroke patients were randomly assigned to the core stabilization exercises (CSE) group, CSE+KT group or CSE+NMES group, respectively. All groups received the training protocol for 30-45 minutes, 3 days a week, for 6 weeks. Lung functions were measured using portable spirometry. Respiratory muscle strength was assessed using an analog manometer to measure maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP). Peak cough flow (PCF) was measured with a peak flow meter. Respiratory muscles thickness were determined using ultrasonography. RESULTS: Except for FVC (%pred) (F=4.432, p=0.018, np2=0.174), FEV1(%pred) (F=3.725, p=0.032, np2=0.151), and MEP (F=3.861, p=0.029, np2=0.155), the overall group by time interaction for rmANOVA showed that there was no statistically significant difference between groups (p>0.05). After post hoc analysis, it was determined that there was no statistically significant difference between the groups in terms of FVC (%pred), FEV1(%pred) and MEP (p>0.025). CONCLUSIONS: The addition of NMES or KT to core stabilization exercises did not appear to provide additional benefit in improving lung function, respiratory muscle strength, and thickness in stroke patients.

15.
Vascular ; : 17085381241257735, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807381

RESUMO

OBJECTIVE: The study aims to evaluate the between-day reliability of a proposed test battery for patients with claudication that can be used for monitoring the effectiveness of exercise interventions and other therapeutic strategies tailored to this patient population. METHODS: Twenty-five men with claudication were recruited. The test battery consisted of the Vastus Lateralis muscle thickness (VL-MT), ankle-brachial pressure index (ABI), unilateral isometric knee extension maximal voluntary torque (MVT) and 6-minute walk test (6MWT). A single investigator conducted the tests for each patient on two separate testing sessions (T1 and T2) 5-7 days apart. RESULTS: Good to excellent reliability was observed for VL-MT (ICC = 0.95, 95% LOA = ±3.10 mm, SEM = 0.81 mm), ABI (ICC = 0.97, 95% LOA = ±0.10, SEM = 0.02), MVT (ICC = 0.97, 95% LOA = ±24.0 N·m, SEM = 6.31 N·m), 6MWT distance (ICC = 0.99, 95% LOA = ±39.6 m, SEM = 11.0 m), 6MWT time to claudication (ICC = 0.99, 95% LOA = ±30.8 s, SEM = 7.8 s), and 6MWT ratings of pain (ICC = 0.87, 95% LOA = ±2.4 CR-10+, SEM = 0.7 CR-10+ ). Analysis derived from reliability data indicates a change of 1.4 mm for VL-MT, 0.14 for ABI, 12 N·m for MVT, 25 m for 6MWT distance, 15 s for 6MWT time to claudication and 1 CR-10+ for 6MWT ratings of pain is required to be interpreted as the minimum 'likely' change (76% chance). CONCLUSIONS: The test battery provides a reliable assessment of patients with claudication and can be widely used to evaluate the effects of exercise programmes and other therapeutic interventions. For the individual, changes in VL-MT, ABI, MVT, and 6MWT greater than the minimum likely change as a result of an exercise programme or an intervention are likely changes and less influenced by error associated with the test.

16.
Healthcare (Basel) ; 12(10)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38786421

RESUMO

Sarcopenia, characterized by progressive muscle loss and functional decline, poses significant risks, including falls, impaired daily activities, and increased mortality. We developed Allgeun, a novel device that measures handgrip strength, muscle mass, and physical performance. This study aimed to investigate whether temporal muscle thickness (TMT) could be used as a sarcopenia marker and to evaluate the usability of Allgeun. This prospective study enrolled 28 participants without medical or neurological disorders. They underwent three-dimensional T1-weighted imaging using a 3 Tesla magnetic resonance imaging scanner. TMT was measured based on T1-weighted images by a board-certified neuroradiologist. Allgeun was used to measure the following three key components of sarcopenia: muscle strength (handgrip strength), muscle mass (calf and thigh circumference), and physical performance (five times the chair stand test). Correlation analysis was conducted between TMT and the results of the handgrip strength, calf and thigh circumferences, and chair stand tests. There were moderate positive correlations between TMT and calf circumference (r = 0.413, p = 0.029), thigh circumference (r = 0.486, p = 0.008), and handgrip strength (r = 0.444, p = 0.018). However, no significant correlation was observed between TMT and physical performance (r = -0.000, p = 0.998). Our findings underscore TMT's potential as an indicator of sarcopenia, particularly regarding muscle mass and strength. Additionally, we demonstrated that the new device, Allgeun, is useful for screening and diagnosing the severity of sarcopenia.

17.
Cancers (Basel) ; 16(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38730613

RESUMO

Metastases are the most frequent intracranial malignant tumors in adults. While Karnofsky Performance Status (KPS) and Clinical Frailty Scale (CFS) are known to have significant impact on overall survival (OS), temporal muscle thickness (TMT) has been postulated to be a promising new parameter to estimate prognosis. Patients who received a resection of one to three brain metastases in our institution were included. Temporal muscle thickness was measured in preoperative MRI scans according to a standardized protocol. In 199 patients, the mean TMT was 7.5 mm (95CI 7.3-7.7) and the mean OS during follow-up was 31.3 months (95CI 24.2-38.3). There was no significant correlation of TMT and preoperative or follow-up CFS and KPS. While CFS and KPS did significantly correlate with OS (p < 0.001 for each), no correlation was demonstrated for TMT. CFS showed a superior prognostic value compared to KPS. TMT failed to show a significant impact on OS or patient performance, whereas the clinical scales (KPS and CFS) demonstrate a good correlation with OS. Due to its superiority over KPS, we strongly recommend the use of CFS to estimate OS in patients with brain metastases.

18.
J Clin Ultrasound ; 52(5): 608-618, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38600828

RESUMO

BACKGROUND AND AIMS: There are limited data on the comparison of body compositions between diabetic and non-diabetic patients. We aimed to compare the muscle mass and fat parameters measured by ultrasonography (USG) and dual-energy x-ray absorptiometry (DXA) between older palliative care patients with and without type 2 diabetes mellitus (DM). METHODS: We conducted a prospective, cross-sectional study. We recorded the demographics, comorbidities, blood pressures, microvascular complications, pressure injuries, ambulation and nutritional status, and laboratory parameters. We measured the handgrip strength with a hand dynamometer and anthropometric parameters. We analyzed the subcutaneous fat thickness, muscle thickness (MT), and cross-sectional area (CSA) of the rectus femoris (RF) and biceps brachii muscles by USG and the total and regional muscle mass and fat parameters by DXA. We performed a regression analysis to examine the independently associated factors of DM. RESULTS: We included 55 patients (mean age: 79.0 ± 8.0 years, 56.4%: female). 43.6% had type 2 DM. The patients with DM had significantly higher glucose and HbA1c levels and lower RFMT and RFCSA values than the patients without DM (p < 0.01, for all). The RFMT was independently associated with DM after adjusting age, sex, and body mass index (Odds ratio = 0.735, 95% confidence interval = 0.565-0.956, p = 0.022). CONCLUSION: Our study demonstrated that the RFMT might be associated with type 2 DM. This was the first study comparing the body compositions measured by USG and DXA between older diabetic and non-diabetic palliative patients with a wide range of laboratory evaluations. Longitudinal, multi-center studies are warranted to understand the underlying mechanisms.


Assuntos
Absorciometria de Fóton , Diabetes Mellitus Tipo 2 , Músculo Esquelético , Cuidados Paliativos , Ultrassonografia , Humanos , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/fisiopatologia , Feminino , Masculino , Absorciometria de Fóton/métodos , Estudos Transversais , Idoso , Ultrassonografia/métodos , Estudos Prospectivos , Músculo Esquelético/diagnóstico por imagem , Cuidados Paliativos/métodos , Idoso de 80 Anos ou mais , Composição Corporal , Tecido Adiposo/diagnóstico por imagem
19.
Indian J Crit Care Med ; 28(4): 404, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38585317

RESUMO

How to cite this article: Bhattacharya D, Esquinas AM, Mandal M. Parasternal Intercostal Muscle Thickness Fraction (PICTF%): Ultrasound a New Tool for Weaning Prediction? Indian J Crit Care Med 2024;28(4):404.

20.
Top Stroke Rehabil ; : 1-10, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38590086

RESUMO

BACKGROUND: Research findings on skeletal muscle degeneration in post-stroke sarcopenic obesity are limited. Thus, this study aimed to investigate the association between post-stroke sarcopenic obesity and quantitative and qualitative changes in skeletal muscles. METHODS: This was a cross-sectional study conducted on patients with stroke admitted to the convalescent rehabilitation ward. For skeletal muscle assessment, an ultrasound system was used to measure quadriceps muscle thickness and echo intensity (QMT and QEI) on the paretic and non-paretic sides. Sarcopenic obesity was defined as the presence of both sarcopenia and obesity. Multiple regression analysis was performed to determine the relationships between sarcopenic obesity and QMT and QEI. RESULTS: A total of 130 patients with stroke were included in this study (mean age: 69.4 ± 12.7 years). The prevalence of sarcopenic obesity was 23.1%. The multiple regression analysis showed that sarcopenic obesity was significantly negatively associated with QMT on both the paretic and non-paretic sides (paretic side: ß = -0.28, p < 0.001; non-paretic side: ß = -0.37, p < 0.001) and significantly positively associated with QEI (paretic side ß = 0.21, p = 0.034; non-paretic side: ß = 0.20, p = 0.029). CONCLUSIONS: Post-stroke sarcopenic obesity was independently associated with quantitative and qualitative changes in skeletal muscles on both the paretic and non-paretic sides.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...