Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.208
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38817687

RESUMO

Objective: A newly launched endoscopy system (EVIS X1, CV-1500; Olympus) is equipped with texture and color enhancement imaging (TXI). We aimed to investigate the efficacy of TXI for the visibility and diagnostic accuracy of non-polypoid colorectal lesions. Methods: We examined 100 non-polypoid lesions in 42 patients from the same position, angle, and distance of the view in three modes: white light imaging (WLI), narrow-band imaging (NBI), and TXI. The primary outcome was to compare polyp visibility in the three modes using subjective polyp visibility score and objective color difference values. The secondary outcome was to compare the diagnostic accuracy without magnification. Results: Overall, the visibility score of TXI was significantly higher than that of WLI (3.7 ± 1.1 vs. 3.6 ± 1.1; p = 0.008) and lower than that of NBI (3.7 ± 1.1 vs. 3.8 ± 1.1; p = 0.013). Color difference values of TXI were higher than those of WLI (11.5 ± 6.9 vs. 9.1 ± 5.4; p < 0.001) and lower than those of NBI (11.5 ± 6.9 vs. 13.1 ± 7.7; p = 0.002). No significant differences in TXI and NBI (visibility score: 3.7 ± 1.0 vs. 3.8 ± 1.1; p = 0.833, color difference values: 11.6 ± 7.1 vs. 12.9 ± 8.3; p = 0.099) were observed for neoplastic lesions. Moreover, the diagnostic accuracy of TXI was significantly higher than that of NBI (65.5% vs. 57.6%, p = 0.012) for neoplastic lesions. Conclusions: TXI demonstrated higher visibility than that of WLI and lower than that of NBI. Further investigations are warranted to validate the performance of the TXI mode comprehensively.

2.
Artigo em Chinês | MEDLINE | ID: mdl-38973047

RESUMO

Objective:To explore efficacy of narrow band imaging(NBI) technique in CO2laser therapy in Early-Stage Glottic cancer. Methods:The clinical data of patients with Early-Stage Glottic cancer who underwent CO2laser vocal cord resection from June 2011 to August 2022 were retrospectively analyzed. Among these, 27 patients who underwent surgery assisted by NBI were assigned to the observation group, while 25 patients who underwent conventional CO2 laser microsurgery with a suspension laryngoscope were assigned to the control group. The differences between the two groups were analyzed in terms of intraoperative frozen pathology results, postoperative recurrence rates, 5-year cumulative disease-free survival rates, complications, and voice recovery. Results:All 52 patients were operated successfully. Temporary tracheostomy and serious complications did not occur during the operation. The postoperative patient's pronunciation was satisfactory. One patient experienced vocal cord adhesion, but there were no severe complications such as breathing difficulties or bleeding, with an overall complication rate of 1.92%. Postoperative follow-up was 1-5 years. The 5 years recurrence free survival in the general group was 77.90%, and the 5 years recurrence free survival in the NBI group was 100%, the difference was statistically significant(P<0.05). NBI endoscopy is safer and more accurate than the general group in determining the safe margin of tumor mucosal resection(P<0.05). Among the patients who accepted the voice analysis, the difference was no statistically significant(P>0.05). Conclusion:Compared with conventional CO2laser surgery under microscope, NBI guided laser resection of Early-Stage Glottic cancer is more accurate. NBI guided laser resection could improve 5 years recurrence free survival rate. In a word, narrow-band imaging endoscopy can has very high value in clinical application.


Assuntos
Glote , Neoplasias Laríngeas , Terapia a Laser , Lasers de Gás , Imagem de Banda Estreita , Humanos , Neoplasias Laríngeas/cirurgia , Neoplasias Laríngeas/diagnóstico por imagem , Neoplasias Laríngeas/patologia , Lasers de Gás/uso terapêutico , Estudos Retrospectivos , Imagem de Banda Estreita/métodos , Masculino , Feminino , Terapia a Laser/métodos , Pessoa de Meia-Idade , Prega Vocal/diagnóstico por imagem , Laringoscopia/métodos , Microcirurgia/métodos , Resultado do Tratamento , Recidiva Local de Neoplasia , Intervalo Livre de Doença , Estadiamento de Neoplasias , Idoso
3.
Front Optoelectron ; 17(1): 18, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38861203

RESUMO

The multiple absorber layer perovskite solar cells (PSCs) with charge transport layers-free (CTLs-free) have drawn widespread research interest due to their simplified architecture and promising photoelectric characteristics. Under the circumstances, the novel design of CTLs-free inversion PSCs with stable and nontoxic three absorber layers (triple Cs3Bi2I9, single MASnI3, double Cs2TiBr6) as optical-harvester has been numerically simulated by utilizing wxAMPS simulation software and achieved high power conversion efficiency (PCE) of 14.8834%. This is owing to the innovative architecture of PSCs favors efficient transport and extraction of more holes and the slender band gap MASnI3 extends the absorption spectrum to the near-infrared periphery compared with the two absorber layers architecture of PSCs. Moreover, the performance of the device with p-type-Cs3Bi2I9/p-type-MASnI3/n-type-Cs2TiBr6 architecture is superior to the one with the p-type-Cs3Bi2I9/n-type-MASnI3/n-type-Cs2TiBr6 architecture due to less carrier recombination and higher carrier life time inside the absorber layers. The simulation results reveal that Cs2TiF6 double perovskite material stands out as the best alternative. Additionally, an excellent PCE of 21.4530% can be obtained with the thicker MASnI3 absorber layer thickness (0.4 µm). Lastly, the highest-performance photovoltaic devices (28.6193%) can be created with the optimized perovskite doping density of around E15 cm3 (Cs3Bi2I9), E18 cm3 (MASnI3), and 1.5E19 cm3 (Cs2TiBr6). This work manifests that the proposed CTLs-free PSCs with multi-absorber layers shall be a relevant reference for forward applications in electro-optical and optoelectronic devices.

4.
Anticancer Res ; 44(7): 2823-2826, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38925805

RESUMO

BACKGROUND/AIM: Genetic reporters encoding fluorescent proteins or luciferase have been used in vivo for the last three decades with claims about their superiority or inferiority over each other. In the present report, a head-to-head in vivo comparison of green fluorescent protein (GFP) fluorescence imaging and luciferase-luciferin imaging, using single-nanometer laser-excitation tuning of fluorescence excitation and an ultra-low-light-detection camera and optics was performed. MATERIALS AND METHODS: Mouse Lewis-lung carcinoma cells labeled with GFP (LLC-GFP) or luciferase (LL/2-Luc2) were injected subcutaneously into the flank of nude mice. One week after injection, GFP-fluorescence imaging and luciferase-luciferin imaging was performed using the UVP Biospectrum Advanced system with excitation at 487 nm and peak emission at 513 nm for GFP, and with emission at 560 nm for luciferase-luciferin. GFP fluorescence images were obtained at 0, 10, and 20 min. Luciferase-luciferin images were obtained 10 and 20 min after the injection of D-luciferin. RESULTS: The intensity of GFP images was 55,909 at 0 min, 56,186 at 10 min, and 57,085 at 20 min, and maintained after 20 min. The intensity of luciferase-luciferin images was 28,065 at 10 min after the injection of D-luciferin and 5,199 at 20 min after the injection. The intensity of luciferase-luciferin images decreased by approximately 80% at 20 min compared to 10 min. An exposure time of 30 s for luciferase-luciferin imaging was needed compared to 100 ms for GFP fluorescence imaging in order to detect signals. CONCLUSION: An imaging system with single-nanometer tuning fluorescence excitation and an ultra-low-light detection camera and optics was able to directly visualize both GFP and luciferase-luciferin images in vivo. The intensity and stability of the signals were both greater for GFP than for luciferase-luciferin, and the exposure time for GFP was 300 times faster, demonstrating the superiority of GFP.


Assuntos
Proteínas de Fluorescência Verde , Luciferases , Camundongos Nus , Animais , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Camundongos , Luciferases/metabolismo , Luciferases/genética , Imagem Óptica/métodos , Linhagem Celular Tumoral , Lasers , Carcinoma Pulmonar de Lewis/metabolismo , Carcinoma Pulmonar de Lewis/diagnóstico por imagem , Carcinoma Pulmonar de Lewis/patologia , Benzotiazóis , Medições Luminescentes/métodos
5.
Bioengineering (Basel) ; 11(6)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38927792

RESUMO

Esophageal carcinoma is the sixth-leading cause of cancer death worldwide. A precursor to esophageal adenocarcinoma (EAC) is Barrett's Esophagus (BE). Early-stage diagnosis and treatment of esophageal neoplasia (Barrett's with high-grade dysplasia/intramucosal cancer) increase the five-year survival rate from 10% to 98%. BE is a global challenge; however, current endoscopes for early BE detection are costly and require extensive infrastructure for patient examination and sedation. We describe the design and evaluation of the first prototype of ScanCap, a high-resolution optical endoscopy system with a reusable, low-cost tethered capsule, designed to provide high-definition, blue-green illumination imaging for the early detection of BE in unsedated patients. The tethered capsule (12.8 mm diameter, 35.5 mm length) contains a color camera and rotating mirror and is designed to be swallowed; images are collected as the capsule is retracted manually via the tether. The tether provides electrical power and illumination at wavelengths of 415 nm and 565 nm and transmits data from the camera to a tablet. The ScanCap prototype capsule was used to image the oral mucosa in normal volunteers and ex vivo esophageal resections; images were compared to those obtained using an Olympus CV-180 endoscope. Images of superficial capillaries in intact oral mucosa were clearly visible in ScanCap images. Diagnostically relevant features of BE, including irregular Z-lines, distorted mucosa, and dilated vasculature, were clearly visible in ScanCap images of ex vivo esophageal specimens.

6.
Curr Med Sci ; 44(3): 554-560, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38842773

RESUMO

OBJECTIVE: This study aimed to compare the performance of standard-definition white-light endoscopy (SD-WL), high-definition white-light endoscopy (HD-WL), and high-definition narrow-band imaging (HD-NBI) in detecting colorectal lesions in the Chinese population. METHODS: This was a multicenter, single-blind, randomized, controlled trial with a non-inferiority design. Patients undergoing endoscopy for physical examination, screening, and surveillance were enrolled from July 2017 to December 2020. The primary outcome measure was the adenoma detection rate (ADR), defined as the proportion of patients with at least one adenoma detected. The associated factors for detecting adenomas were assessed using univariate and multivariate logistic regression. RESULTS: Out of 653 eligible patients enrolled, data from 596 patients were analyzed. The ADRs were 34.5% in the SD-WL group, 33.5% in the HD-WL group, and 37.5% in the HD-NBI group (P=0.72). The advanced neoplasm detection rates (ANDRs) in the three arms were 17.1%, 15.5%, and 10.4% (P=0.17). No significant differences were found between the SD group and HD group regarding ADR or ANDR (ADR: 34.5% vs. 35.6%, P=0.79; ANDR: 17.1% vs. 13.0%, P=0.16, respectively). Similar results were observed between the HD-WL group and HD-NBI group (ADR: 33.5% vs. 37.7%, P=0.45; ANDR: 15.5% vs. 10.4%, P=0.18, respectively). In the univariate and multivariate logistic regression analyses, neither HD-WL nor HD-NBI led to a significant difference in overall adenoma detection compared to SD-WL (HD-WL: OR 0.91, P=0.69; HD-NBI: OR 1.15, P=0.80). CONCLUSION: HD-NBI and HD-WL are comparable to SD-WL for overall adenoma detection among Chinese outpatients. It can be concluded that HD-NBI or HD-WL is not superior to SD-WL, but more effective instruction may be needed to guide the selection of different endoscopic methods in the future. Our study's conclusions may aid in the efficient allocation and utilization of limited colonoscopy resources, especially advanced imaging technologies.


Assuntos
Adenoma , Colonoscopia , Neoplasias Colorretais , Imagem de Banda Estreita , Humanos , Masculino , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico , Feminino , Pessoa de Meia-Idade , Adenoma/diagnóstico por imagem , Adenoma/diagnóstico , Imagem de Banda Estreita/métodos , Colonoscopia/métodos , Idoso , Método Simples-Cego , Luz , Adulto
7.
J Pharm Bioallied Sci ; 16(Suppl 2): S1072-S1076, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38882810

RESUMO

Recent advancements in oral cancer detection prioritize non-invasive and minimally invasive techniques for efficient and accurate screening. This review outlines progress in methods such as narrow band imaging, fluorescence imaging, and optical coherence tomography, showing promise in early lesion detection. Biomarker detection in saliva and targeted nanoparticles enhance early diagnosis, while machine learning improves diagnostic accuracy. However, clinical validation and large-scale studies are needed for widespread adoption.

8.
J Med Imaging (Bellingham) ; 11(3): 036002, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38827776

RESUMO

Purpose: Early detection of cancer is crucial for lung cancer patients, as it determines disease prognosis. Lung cancer typically starts as bronchial lesions along the airway walls. Recent research has indicated that narrow-band imaging (NBI) bronchoscopy enables more effective bronchial lesion detection than other bronchoscopic modalities. Unfortunately, NBI video can be hard to interpret because physicians currently are forced to perform a time-consuming subjective visual search to detect bronchial lesions in a long airway-exam video. As a result, NBI bronchoscopy is not regularly used in practice. To alleviate this problem, we propose an automatic two-stage real-time method for bronchial lesion detection in NBI video and perform a first-of-its-kind pilot study of the method using NBI airway exam video collected at our institution. Approach: Given a patient's NBI video, the first method stage entails a deep-learning-based object detection network coupled with a multiframe abnormality measure to locate candidate lesions on each video frame. The second method stage then draws upon a Siamese network and a Kalman filter to track candidate lesions over multiple frames to arrive at final lesion decisions. Results: Tests drawing on 23 patient NBI airway exam videos indicate that the method can process an incoming video stream at a real-time frame rate, thereby making the method viable for real-time inspection during a live bronchoscopic airway exam. Furthermore, our studies showed a 93% sensitivity and 86% specificity for lesion detection; this compares favorably to a sensitivity and specificity of 80% and 84% achieved over a series of recent pooled clinical studies using the current time-consuming subjective clinical approach. Conclusion: The method shows potential for robust lesion detection in NBI video at a real-time frame rate. Therefore, it could help enable more common use of NBI bronchoscopy for bronchial lesion detection.

10.
Scand J Gastroenterol ; 59(7): 875-879, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38700462

RESUMO

BACKGROUND: We previously reported unusual adenomas with proliferative zones confined to the lower two-thirds of the crypt. The proliferative zones of colorectal adenomas have three patterns: 'lower,' 'superficial' and 'entire'. This study aimed to clarify the characteristics of each adenoma pattern. METHODS: We investigated 2925 consecutive patients who underwent colonoscopy at our institute. All polyps that were removed were histologically examined using hematoxylin and eosin staining. The location of the proliferative zone was assessed for adenomas. Data were compared using Dunn's and Kruskal-Wallis tests. RESULTS: Colorectal adenomas with 'lower' proliferative zone often appeared similar to hyperplastic polyps (42.8%), and the frequency was significantly higher than that of adenomas with 'superficial' and 'entire' proliferative zones (p < 0.001). The mean sizes of adenomas were 2.4, 3.0 and 3.9 mm for 'lower,' 'superficial' and 'entire' proliferative zones, respectively. A significant gradual increase was observed. Regarding morphology, the proportion of type 0-I in adenomas with an 'entire' proliferative zone was significantly higher than that in adenomas with 'superficial' proliferative zone (p < 0.001). CONCLUSION: While colorectal adenomas develop and increase in size, the proliferative zone appears to shift upward and become scattered.


Assuntos
Adenoma , Pólipos do Colo , Colonoscopia , Humanos , Adenoma/patologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Pólipos do Colo/patologia , Neoplasias Colorretais/patologia , Adulto , Neoplasias do Colo/patologia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Proliferação de Células , Hiperplasia/patologia
11.
Angew Chem Int Ed Engl ; : e202407007, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806441

RESUMO

Designing and synthesizing narrow band gap acceptors that exhibit high photoluminescence quantum yield (PLQY) and strong crystallinity is a highly effective, yet challenging, approach to reducing non-radiative energy losses (▵Enr) and boosting the performance of organic solar cells (OSCs). We have successfully designed and synthesized an A-D-A type fused-ring electron acceptor, named DM-F, which features a planar molecular backbone adorned with bulky three-dimensional camphane side groups at its central core. These bulky substituents effectively hinder the formation of H-aggregates of the acceptors, promoting the formation of more J-aggregates and notably elevating the PLQY of the acceptor in the film. As anticipated, DM-F showcases pronounced near-infrared absorption coupled with impressive crystallinity. Organic solar cells (OSCs) leveraging DM-F exhibit a high EQEEL value and remarkably low ▵Enr of 0.14 eV-currently the most minimal reported value for OSCs. Moreover, the power conversion efficiency (PCE) of binary and ternary OSCs utilizing DM-F has reached 16.16 % and 20.09 %, respectively, marking a new apex in reported efficiency within the OSCs field. In conclusion, our study reveals that designing narrow band gap acceptors with high PLQY is an effective way to reduce ▵Enr and improve the PCE of OSCs.

12.
Angew Chem Int Ed Engl ; : e202407277, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780892

RESUMO

Chiral multi-resonance thermally activated delayed fluorescence (CP-MR-TADF) materials hold promise for circularly polarized organic light-emitting diodes (CP-OLEDs) and 3D displays. Herein, we present two pairs of tetraborated intrinsically axial CP-MR-TADF materials, R/S-BDBF-BOH and R/S-BDBT-BOH, with conjugation-extended bidibenzo[b,d]furan and bidibenzo[b,d]thiophene as chiral sources, which effectively participate in the distribution of the frontier molecular orbitals. Due to the heavy-atom effect, sulfur atoms are introduced to accelerate the reverse intersystem crossing process and increase the efficiency of molecules. R/S-BDBF-BOH and R/S-BDBT-BOH manifest ultra-pure blue emission with a maximum at 458/459 nm with a full width at half maximum of 27 nm, photoluminescence quantum yields of 90 %/91 %, and dissymmetry factors (|gPL|) of 6.8×10-4/8.5×10-4, respectively. Correspondingly, the CP-OLEDs exhibit good performances with an external quantum efficiency of 30.1 % and |gEL| factors of 1.2×10-3.

13.
JGH Open ; 8(5): e13058, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38737501

RESUMO

Background and Aim: Small rectosigmoid colorectal polyps (<10 mm) are prevalent, with a low prevalence of advanced neoplastic lesions. The "diagnose-and-leave" strategy, employing narrow band imaging (NBI), is gaining popularity for its safety and cost-effectiveness by reducing polypectomy complications and minimizing histopathology expenses. This study assessed the diagnostic efficacy of NBI with dual focus (DF) magnification for real-time neoplastic prediction of rectosigmoid polyps and explored the feasibility of implementing this strategy in Vietnam. Methods: In a prospective single-center study, 307 rectosigmoid polyps from 245 patients were analyzed using three consecutive endoscopic modes: white light endoscopy (WLE), NBI, and NBI-DF. Endoscopists assessed polyps for size, location, macroscopic shape, optical diagnosis, and confidence levels before histopathological evaluation. High confidence was assigned when the polyp exhibited all features of a single histology type. Predictions were compared with final histopathology results. Results: Of the total, 237 (77.2%) were diminutive (≤5 mm) polyps, and 18 (5.8%) were advanced neoplastic lesions. WLE + NBI and WLE + NBI + NBI-DF exhibited significantly higher accuracy compared to WLE (88.6% and 90.2% vs 74.2%, P < 0.01). For diminutive polyps, the DF mode significantly increased the rate of high-confidence optical diagnoses (89.1% vs 94.9%, P < 0.001). WLE + NBI + NBI-DF demonstrated high sensitivity (90.1%), specificity (95.5%), and negative predictive value (93.4%) in high-confidence predictions, enabling the implementation of the "diagnose-and-leave" strategy. This approach would have reduced 58.2% of unnecessary polypectomies without missing any advanced neoplastic lesions. Conclusion: NBI and DF modes provide accurate neoplastic predictions for rectosigmoid polyps. For diminutive polyps, DF magnification improves the confidence level of the optical diagnosis, allowing the safe implementation of the "diagnose-and-leave" strategy.

14.
Laryngoscope ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38801129

RESUMO

OBJECTIVES: Vocal fold leukoplakia (VFL) is a precancerous lesion of laryngeal cancer, and its endoscopic diagnosis poses challenges. We aim to develop an artificial intelligence (AI) model using white light imaging (WLI) and narrow-band imaging (NBI) to distinguish benign from malignant VFL. METHODS: A total of 7057 images from 426 patients were used for model development and internal validation. Additionally, 1617 images from two other hospitals were used for model external validation. Modeling learning based on WLI and NBI modalities was conducted using deep learning combined with a multi-instance learning approach (MIL). Furthermore, 50 prospectively collected videos were used to evaluate real-time model performance. A human-machine comparison involving 100 patients and 12 laryngologists assessed the real-world effectiveness of the model. RESULTS: The model achieved the highest area under the receiver operating characteristic curve (AUC) values of 0.868 and 0.884 in the internal and external validation sets, respectively. AUC in the video validation set was 0.825 (95% CI: 0.704-0.946). In the human-machine comparison, AI significantly improved AUC and accuracy for all laryngologists (p < 0.05). With the assistance of AI, the diagnostic abilities and consistency of all laryngologists improved. CONCLUSIONS: Our multicenter study developed an effective AI model using MIL and fusion of WLI and NBI images for VFL diagnosis, particularly aiding junior laryngologists. However, further optimization and validation are necessary to fully assess its potential impact in clinical settings. LEVEL OF EVIDENCE: 3 Laryngoscope, 2024.

15.
Gastroenterology Res ; 17(2): 72-81, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38716285

RESUMO

Background: Photodynamic therapy (PDT) has advanced through the utilization of photosensitizers and specific-wavelength light (≥ 600 nm). However, the widespread adoption of PDT is still impeded by high equipment costs and stringent laser safety requirements. Porphyrins, crucial in PDT, have another absorbance peak of blue light (λ = 380 - 500 nm). This peak corresponds to the wavelength of narrow-band imaging (NBI) (λ = 390 - 445 nm), an image-enhancement technology integrated into endoscopes by Olympus Medical Systems. The study aimed to investigate the potential of widely adopted NBI as a PDT light source for superficial cancers via endoscopes. Methods: Esophageal and biliary cancers were selected for investigation. Human esophageal cancer cell lines (KYSE30, KYSE70, KYSE170) and cholangiocarcinoma cell lines (HuCCT-1, KKU-213) were subjected to verteporfin-mediated PDT under NBI light (λ = 390 - 445 nm). Assessments included spectrometry, crystal violet staining, and fluorescein imaging of singlet oxygen generation and apoptosis. Results: Verteporfin exhibited a peak (λ = 436 nm) consistent with the NBI spectrum, suggesting compatibility with NBI light. NBI light significantly inhibited the growth of esophageal and biliary cancer cells. The half-maximum effective concentration (EC50) values (5 J/cm2) for KYSE30, KYSE70, KYSE170, HuCCT-1, and KKU-213 were calculated as 2.78 ± 0.37µM, 1.76 ± 1.20 µM, 0.77 ± 0.16 µM, 0.65 ± 0.18 µM, and 0.32 ± 0.04 µM, respectively. Verteporfin accumulation in mitochondria, coupled with singlet oxygen generation and observed apoptotic changes, suggests effective PDT under NBI light. Conclusions: NBI is a promising PDT light source for superficial cancers via endoscopes.

16.
Laryngoscope ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38727522

RESUMO

INTRODUCTION: Narrow-band imaging (NBI) can improve detection of lesions in the aerodigestive tract. However, its role in benign lesions of the larynx is unclear. This study aims to determine whether NBI improves the detection of scars, sulci, and nodules compared to panchromatic lighting using objective image analysis. METHODS: In total, 120 vocal folds (VFs) were analyzed with and without NBI (21 normal, 15 scars, 16 sulci, and 45 nodules). Each VF image had anterior, middle, and posterior thirds analyzed for brightness using an area morphometry software (Optimas 5.1a). The middle-third with the lesion was analyzed against surrounding VF segments for average and standard deviation (SD) in absolute grayscale. RESULTS: The use of panchromatic light resulted in greater illumination and grayscale values than NBI. All lesions tended to be in the mid-membranous fold. Under panchromatic light, change in brightness when comparing anterior versus middle (A-M) was +6.1% for normal, versus 6.5%, 8.1%, and 7.1% for sulci, nodules, and scars, respectively. Under NBI, they were 9.0% (normal), 12.3% (sulci), 13.7% (nodules), and 13.1% (scars). A greater SD of luminescence was observed at pathology sites (p < 0.05) when using NBI. The change in absolute grayscale at all lesion sites was greater when using NBI than when using panchromatic light (p < 0.05). CONCLUSION: NBI significantly enhanced the area of pathology in patients with nodules, sulci, and scars. Greater SD values in grayscale at pathologic sites were observed compared at normal sites. Thus, NBI may improve the detection of phonotraumatic lesions compared to panchromatic light. LEVEL OF EVIDENCE: N/A Laryngoscope, 2024.

17.
Clin Case Rep ; 12(5): e8913, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38741676

RESUMO

Squamous cell papilloma with elongated villous projections may occur in the hypopharynx and present with symptoms observable on physical examination.

18.
Cureus ; 16(4): e58200, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38741849

RESUMO

The pterygopalatine fossa and infratemporal fossa are often approached through an external incision because of their deep facial location, but this can present problems such as facial scarring and deformity. In schwannoma surgery, intraneural dissection is a useful surgical technique for achieving gross total resection while preserving the capsule, including the nerves. For appropriate enucleation and preservation of the functional nerve, it is indispensable to distinguish between the pseudocapsule and the tumor capsule. This case report presents a case of endonasal surgical intervention for an extracranial trigeminal schwannoma employing the tri-port approach and narrow-band imaging.

19.
Am J Otolaryngol ; 45(4): 104296, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38653084

RESUMO

BACKGROUND: Narrow-band imaging (NBI) endoscopy is used in various tumor detection and is important in detecting early tumors. OBJECTIVE: To explore the application value of NBI endoscopy in diagnosing pharyngeal tumors. MATERIAL AND METHODS: Ninety-one patients with pharyngeal masses who attended the Department of Otorhinolaryngology, Head and Neck Surgery in Gansu Provincial Hospital from January 2023 to February 2024 were selected, and NBI and white light (WL) endoscopy were applied to examine the pharynx and the relationship between the two was observed. SPSS 25.0 software was used for statistical analysis. RESULTS: The sensitivity of NBI endoscopy for diagnosing laryngeal malignant lesions was 92.0 %, the specificity was 93.0 %, the positive predictive value was 88.5 %, and the negative predictive value was 95.2 %, with a high degree of concordance between the results of NBI endoscopy and the pathology; WL endoscopy had a sensitivity of 64.0 %, a specificity of 76. 7 %, a positive predictive value of 61.5 %, and a negative predictive value of 78.6 %, with WL endoscopic findings had moderate concordance with pathology. The diagnostic accuracy of NBI endoscopy was higher than that of WL endoscopy for both benign and malignant lesions and precancerous lesions. CONCLUSION: NBI endoscopy can detect laryngeal cancer lesions more accurately.


Assuntos
Endoscopia , Imagem de Banda Estreita , Neoplasias Faríngeas , Sensibilidade e Especificidade , Humanos , Imagem de Banda Estreita/métodos , Neoplasias Faríngeas/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Endoscopia/métodos , Valor Preditivo dos Testes , Idoso de 80 Anos ou mais , Neoplasias Laríngeas/diagnóstico por imagem , Neoplasias Laríngeas/patologia
20.
World J Gastrointest Endosc ; 16(3): 157-167, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38577642

RESUMO

BACKGROUND: Conventional magnifying endoscopy with narrow-band imaging (NBI) observation of the gastric body mucosa shows dominant patterns in relation to the regular arrangement of collecting venules, subepithelial capillary network, and gastric pits. AIM: To evaluate the effectiveness of a new one-dual (near) focus, NBI mode in the assessment of the microscopic features of gastric body mucosa compared to conventional magnification. METHODS: During 2021 and 2022, 68 patients underwent proximal gastrointestinal endoscopy using magnification endoscopic modalities subsequently applying acetic acid (AA). The GIF-190HQ series NBI system with dual focus capability was used for the investigation of gastric mucosa. At the time of the endoscopy, the gastric body mucosa of all enrolled patients was photographed using the white light endoscopy (WLE), near focus (NF), NF-NBI, AA-NF, and AA-NF-NBI modes. RESULTS: The WLE, NF and NF-NBI endoscopic modes for all patients (204 images) were classified in the same order into three groups. Two images from each patient for the AA-NF and AA-NF-NBI endoscopic modes were classified in the same order. According to all three observers who completed the work independently, NF magnification was significantly superior to WLE (P < 0.01), and the NF-NBI mode was significantly superior to NF magnification (P < 0.01). After applying AA, the three observers confirmed that AA-NF-NBI was significantly superior to AA-NF (P < 0.01). Interobserver kappa values for WLE were 0.609, 0.704, and 0.598, respectively and were 0.600, 0.721, and 0.637, respectively, for NF magnification. For the NF-NBI mode, the values were 0.378, 0.471, and 0.553, respectively. For AA-NF, they were 0.453, 0.603, and 0.480, respectively, and for AA-NF-NBI, they were 0.643, 0.506, and 0.354, respectively. CONCLUSION: When investigating gastric mucosa in microscopic detail, NF-NBI was the most powerful endoscopic mode for assessing regular arrangement of collecting venules, subepithelial capillary network, and gastric pits among the five endoscopic modalities investigated in this study. AA-NF-NBI was the most powerful endoscopic mode for analyzing crypt opening and intervening part.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...