Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 549
Filtrar
1.
J Craniovertebr Junction Spine ; 15(2): 224-229, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38957756

RESUMO

Introduction: Transpedicular screw placement has superior pullout strength compared to alternative forms of spinal fusion and is often performed in deformity correction surgery with navigation for optimal accuracy and reliability. Freehand technique for pedicle screws minimizes operation time and radiation exposure without fluoroscopy but is not widely adopted given the challenge of difficult anatomical corridors and accurate placement, especially in idiopathic scoliosis and advanced deformity. We used a computer-generated model to assess a proof-of-concept and anatomical feasibility of a freehand screw technique in severe scoliosis. Methods: Three-dimensional (3D) reconstructions of vertebra from a sample of two male patients with severe idiopathic scoliosis deformity (1 thoracic and 1 lumbar) with Cobb angles of 100° were used for planned placement of 17 levels of thoracolumbar (6.5 mm × 45 mm) pedicle screws. 3D reconstruction of each vertebra was created and measurements of screw entries and trajectories were reproduced with a 3D slicer software image computing platform. Results: Accurate transpedicular screw placement is possible with anatomical landmarks based on the 3D reconstructed vertebral levels. A series of 5 figures were assembled to demonstrate sagittal, coronal, and axial planes and key anatomical landmarks and trajectories of thoracic and lumbar freehand pedicle screws in severe idiopathic scoliosis. Conclusions: Anatomical landmarks for freehand transpedicular screw placement (between pedicle, lamina, and superior articulating process) are constant and reliable in severe idiopathic scoliosis as evidenced by 3D computer modeling. Preoperative computed tomography modeling may assist appropriate screw entry and trajectory based on anatomical landmarks for spine surgeons, and guide freehand technique for screw placement in adolescent idiopathic scoliosis.

2.
J Neurosurg Spine ; : 1-13, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38968628

RESUMO

OBJECTIVE: Pedicle screw placement guidance is critical in spinal fusions, and spinal surgery robots aim to improve accuracy and reduce complications. Current literature has yet to compare the relative merits of available robotic systems. In this review, the authors aimed to 1) assess the current state of spinal robotics literature; 2) conduct a meta-analysis of robotic performance based on accuracy, speed, and safety; and 3) offer recommendations for robotic system selection. METHODS: Following PRISMA guidelines, the authors conducted a systematic literature review across PubMed, Embase, Cochrane Library, Web of Science, and Scopus as of April 28, 2022, for studies on approved robots for placing lumbar pedicle screws. Three reviewers screened and extracted data relating to the study characteristics, accuracy rate, intraoperative revisions, and reoperations. Secondary performance metrics included operative time, blood loss, and radiation exposure. The authors statistically compared the performance of the robots using a random-effects model to account for variation within and between the studies. Each robot was also compared with performance benchmarks of traditional techniques including freehand, fluoroscopic, and CT-navigated insertion. Finally, we performed a Duval and Tweedie trim-and-fill test to assess for the presence of publication bias. RESULTS: The authors identified 46 studies, describing 4670 patients and 25,054 screws, that evaluated 4 different robotic systems: Mazor X, ROSA, ExcelsiusGPS, and Cirq. The weighted accuracy rates of Gertzbein-Robbins classification grade A or B screws were as follows: ExcelsiusGPS, 98.0%; ROSA, 98.0%; Mazor, 98.2%; and Cirq, 94.2%. No robot was significantly more accurate than the others. However, the accuracy of the ExcelsiusGPS was significantly higher than that of traditional methods, and the accuracies of the Mazor and ROSA were significantly higher than that of fluoroscopy. The intraoperative revision rates were Cirq, 0.55%; ROSA, 0.91%; Mazor, 0.98%; and ExcelsiusGPS, 1.08%. The reoperation rates were Cirq, 0.28%; ExcelsiusGPS, 0.32%; and Mazor, 0.76% (no reoperations were reported for ROSA). Operative times were similar for all robots. Both the ExcelsiusGPS and Mazor were associated with significantly less blood loss than the ROSA. The Cirq had the lowest radiation exposure. Robots tended to be more accurate and generally their use was associated with fewer reoperations and less blood loss than freehand, fluoroscopic, or CT-navigated techniques. CONCLUSIONS: Robotic platforms perform comparably based on key metrics, with high accuracy rates and low intraoperative revision and reoperation rates. The spinal robotics publication rate will continue to accelerate, and choosing a robot will depend on the context of the practice.

3.
ACS Appl Mater Interfaces ; 16(25): 31983-31996, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38865688

RESUMO

Effective osteointegration is of great importance for pedicle screws in spinal fusion surgeries. However, the lack of osteoinductive activity of current screws diminishes their feasibility for osteointegration and fixation, making screw loosening a common complication worldwide. In this study, Ti-6Al-4V pedicle screws with full through-hole design were fabricated via selective laser melting (SLM) 3D printing and then deposited with porous oxide coatings by microarc oxidation (MAO). The porous surface morphology of the oxide coating and the release of bioactive ions could effectively support cell adhesion, migration, vascularization, and osteogenesis in vitro. Furthermore, an in vivo goat model demonstrated the efficacy of modified screws in improving bone maturation and osseointegration, thus providing a promising method for feasible orthopedic internal fixation.


Assuntos
Cerâmica , Cabras , Osseointegração , Oxirredução , Parafusos Pediculares , Impressão Tridimensional , Titânio , Animais , Osseointegração/efeitos dos fármacos , Titânio/química , Titânio/farmacologia , Cerâmica/química , Cerâmica/farmacologia , Ligas/química , Ligas/farmacologia , Osteogênese/efeitos dos fármacos , Humanos , Porosidade , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Adesão Celular/efeitos dos fármacos
4.
BMC Musculoskelet Disord ; 25(1): 458, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858717

RESUMO

BACKGROUND: Minimally invasive posterior fixation surgery for pyogenic spondylitis is known to reduce invasiveness and complication rates; however, the outcomes of concomitant insertion of pedicle screws (PS) into the infected vertebrae via the posterior approach are undetermined. This study aimed to assess the safety and efficacy of PS insertion into infected vertebrae in minimally invasive posterior fixation for thoracolumbar pyogenic spondylitis. METHODS: This multicenter retrospective cohort study included 70 patients undergoing minimally invasive posterior fixation for thoracolumbar pyogenic spondylitis across nine institutions. Patients were categorized into insertion and skip groups based on PS insertion into infected vertebrae, and surgical data and postoperative outcomes, particularly unplanned reoperations due to complications, were compared. RESULTS: The mean age of the 70 patients was 72.8 years. The insertion group (n = 36) had shorter operative times (146 versus 195 min, p = 0.032) and a reduced range of fixation (5.4 versus 6.9 vertebrae, p = 0.0009) compared to the skip group (n = 34). Unplanned reoperations occurred in 24% (n = 17) due to surgical site infections (SSI) or implant failure; the incidence was comparable between the groups. Poor infection control necessitating additional anterior surgery was reported in four patients in the skip group. CONCLUSIONS: PS insertion into infected vertebrae during minimally invasive posterior fixation reduces the operative time and range of fixation without increasing the occurrence of unplanned reoperations due to SSI or implant failure. Judicious PS insertion in patients with minimal bone destruction in thoracolumbar pyogenic spondylitis can minimize surgical invasiveness.


Assuntos
Vértebras Lombares , Procedimentos Cirúrgicos Minimamente Invasivos , Duração da Cirurgia , Parafusos Pediculares , Espondilite , Vértebras Torácicas , Humanos , Estudos Retrospectivos , Masculino , Feminino , Idoso , Vértebras Torácicas/cirurgia , Vértebras Lombares/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Espondilite/cirurgia , Espondilite/diagnóstico por imagem , Espondilite/microbiologia , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Fusão Vertebral/métodos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentação , Resultado do Tratamento , Reoperação , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/prevenção & controle
5.
J Clin Med ; 13(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38731218

RESUMO

Background: Although several biomechanical studies have been reported, few clinical studies have compared the efficacy of monoaxial and polyaxial pedicle screws in the surgical treatment of adolescent idiopathic scoliosis (AIS). This study aims to compare the radiological and clinical outcomes of mono- and polyaxial pedicle screws in the surgical treatment of AIS. Methods: A total of 46 AIS patients who underwent surgery to treat scoliosis using pedicle screw instrumentation (PSI) and rod derotation (RD) were divided into two groups according to the use of pedicle screws: the monoaxial group (n = 23) and polyaxial group (n = 23). Results: The correction rate of the main Cobb's angle was higher in the monoaxial group (70.2%) than in the polyaxial group (65.3%) (p = 0.040). No differences in the rotational correction of the apical vertebra were evident between the two groups. SRS-22 scores showed no significant differences according to the type of pedicle screws used. Conclusions: The use of polyaxial pedicle screws resulted in coronal, sagittal, and rotational correction outcomes comparable to those associated with the use of monoaxial pedicle screws for surgical treatment using PSI and RD to treat moderate cases of AIS.

6.
Zhongguo Gu Shang ; 37(5): 470-6, 2024 May 25.
Artigo em Chinês | MEDLINE | ID: mdl-38778530

RESUMO

OBJECTIVE: To explore the clinical effect of percutaneous pedicle screw anchored vertebral augmentation(PPSAVA) in the treatment of asymptomatic Kümmell disease without neurological symptoms. METHODS: The clinical data of 20 patients with Kümmell disease without neurological symptoms treated with PPSAVA in our hospital from January 2019 to December 2021 were analyzed retrospectively, including 5 males and 15 females, aged 56 to 88 (74.95±9.93) years old. and the course of disease was 7 to 60 days with an average of (21.35±14.46) days. All patients were treated with PPSAVA. The time of operation, the amount of bone cement injected and the leakage of bone cement were recorded. The visual analogue scale(VAS), Oswestry disability index(ODI), vertebral body angle(VBA), anterior edge height and midline height of vertebral body were compared among the before operation, 3 days after operation and during the final follow-up. The loosening and displacement of bone cement were observed during the final follow-up. RESULTS: All the 20 patients completed the operation successfully. The operation time was 30 to 56 min with an average of (41.15±7.65) min, and the amount of bone cement injection was 6.0 to 12.0 ml with an average of (9.30±1.49) ml. Bone cement leakage occurred in 6 cases and there were no obvious clinical symptoms. The follow-up time was 6 to 12 months with an average of (8.43±2.82) months. The VBA, anterior edge height and midline height of of injured vertebral body were significantly improved 3 days after operation and the final follow-up(P<0.05), and the VBA, anterior edge height and midline height of of injured vertebral body were lost in different degrees at the final follow-up (P<0.05). The VAS and ODI at 3 days after operation and at the final follow-up were significantly lower than those at preoperatively(P<0.05), but the VAS score and ODI at the final follow-up were not significantly different from those at 3 d after operation(P>0.05). At the last follow-up, no patients showed loosening or displacement of bone cement. CONCLUSION: PPSAVA is highly effective in treating Kümmell disease without neurological symptoms, improving patients' pain and functional impairment, and reducing the risk of cement loosening and displacement postoperatively.


Assuntos
Parafusos Pediculares , Humanos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Fraturas da Coluna Vertebral/cirurgia , Cimentos Ósseos
7.
Neurospine ; 21(1): 116-127, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38569638

RESUMO

OBJECTIVE: This study aimed to assess the degree of interest in robot-assisted spine surgery (RASS) among residents and to investigate the learning curve for beginners performing robotic surgery. METHODS: We conducted a survey to assess awareness and interest in RASS among young neurosurgery residents. Subsequently, we offered a hands-on training program using a dummy to educate one resident. After completing the program, the trained resident performed spinal fusion surgery with robotic assistance under the supervision of a mentor. The clinical outcomes and learning curve associated with robotic surgery were then analyzed. RESULTS: Neurosurgical residents had limited opportunities to participate in spinal surgery during their training. Despite this, there was a significant interest in the emerging field of robotic surgery. A trained resident performed RASS under the supervision of a senior surgeon. A total of 166 screw insertions were attempted in 28 patients, with 2 screws failing due to skiving. According to the Gertzbein-Robbins classification, 85.54% of the screws were rated as grade A, 11.58% as grade B, 0.6% as grade C, and 1.2% as grade D. The clinical acceptance rate was approximately 96.99%, which is comparable to the results reported by senior experts and time per screw statistically significantly decreased as experience was gained. CONCLUSION: RASS can be performed with high accuracy within a relatively short timeframe, if residents receive adequate training.

8.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 466-473, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632068

RESUMO

Objective: To investigate the effectiveness of injured vertebra fixation with inclined-long pedicle screws combined with interbody fusion for thoracolumbar fracture dislocation with disc injury. Methods: Between January 2017 and June 2022, 28 patients with thoracolumbar fracture dislocation with disc injury were underwent posterior depression, the injured vertebra fixation with inclined-long pedicle screws, and interbody fusion. There were 22 males and 6 females, with a mean age of 41.4 years (range, 22-58 years). The causes of injury included falling from height in 18 cases, traffic accident in 5 cases, and bruise in 5 cases. Fracture segment included 1 case of T 11, 7 cases of T 12, 9 cases of L 1, and 11 cases of L 2. According to the American Spinal Injury Association (ASIA) scale, the spinal injuries were graded as grade A in 4 cases, grade B in 2 cases, grade C in 11 cases, and grade D in 11 cases. Preoperative spinal canal encroachment ratio was 17.7%-75.3% (mean, 44.0%); the thoracolumbar injury classification and severity score (TLICS) ranged from 9 to 10 (mean, 9.9). Seventeen patients were associated with other injuries. The time from injury to operation ranged from 1 to 4 days (mean, 2.3 days). The perioperative indicators (operation time, intraoperative blood loss, and the occurrence of complications), clinical evaluation indicators [visual analogue scale (VAS) score and Oswestry Disability Index (ODI)], radiologic evaluation indicators [anterior vertebral height ratio (AVHR), kyphosis Cobb angle (KCA), intervertebral space height (ISH), vertebral wedge angle (VWA), displacement angle (DA), and percent fracture dislocation displacement (PFDD)], neurological function, and interbody fusion were recorded. Results: The operation time was 110-159 minutes (mean, 130.2 minutes). The intraoperative blood loss was 200-510 mL (mean, 354.3 mL). All incisions healed by first intention, and no surgical complications such as wound infection or hematoma occurred. All patients were followed up 12-15 months (mean, 12.7 months). The chest and lumbar pain significantly relieved, VAS scores and ODI after operation were significantly lower than those before operation, and further decreased with the extension of postoperative time, with significant differences ( P<0.05). At last follow-up, the ASIA classification of neurological function of the patients was grade A in 3 cases, grade B in 1 case, grade C in 1 case, grade D in 10 cases, and grade E in 13 cases, which was significantly different from preoperative one ( Z=-4.772, P<0.001). Imaging review showed that AVHR, KCA, ISH, VWA, DA, and PFDD significantly improved at 1 week, 3 months and last follow-up ( P<0.05). There was no significant difference between different time points after operation ( P>0.05). At last follow-up, according to the modified Brantigan score, all patients achieved good intervertebral bone fusion, including 22 complete fusion and 6 good intervertebral fusion with a few clear lines. No complications such as internal fixation failure or kyphosis occurred during follow-up. Conclusion: The injured vertebra fixation with inclined-long pedicle screws combined with interbody fusion is an effective treatment for thoracolumbar fracture dislocation with disc injury, which can correct the fracture dislocation, release the nerve compression, restore the injured vertebral height, and reconstruct spinal stabilization.


Assuntos
Fratura-Luxação , Fraturas Ósseas , Cifose , Parafusos Pediculares , Fraturas da Coluna Vertebral , Adulto , Feminino , Humanos , Masculino , Perda Sanguínea Cirúrgica , Fixação Interna de Fraturas/métodos , Vértebras Lombares/cirurgia , Estudos Retrospectivos , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/cirurgia , Resultado do Tratamento , Adulto Jovem , Pessoa de Meia-Idade
9.
J Clin Med ; 13(8)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38673447

RESUMO

Background: Modern surgical techniques allow for the correction of spinal deformity, stopping its progression and improving pain relief and social and physical functioning. These instruments have different implant designs, screws, and rod diameters and can be composed of different metal alloys with different hardnesses, which can have a significant impact on the effect of correcting spinal deformities. We designed a retrospective cohort study based on the same surgical technique and spine system using different implant sizes, and compared the results across them. Methods: This is a retrospective review of adolescent idiopathic scoliosis (AIS) patients who underwent posterior spinal fusion (PSF) between 2016 and 2022 with a minimum two-year follow-up (FU) using two spinal implant systems: 5.5 and 6.0 mm diameter screws with double 5.5 mm titanium rods (Group 1 (G1)), and 6.0 and 6.5 mm diameter pedicle screws with double 6.0 mm cobalt-chromium rods (Group 2 (G2)). The evaluated data were as follows: preoperative personal data, radiographic outcomes, complications, and health-related quality of life questionnaire (HRQoL). The parameters were reviewed preoperatively, after the final fusion, and during the FU. Results: The mean age of all 260 patients at surgery was 14.8 years. The average BMI was also similar in both groups and was noted as 21. The mean levels of fusion and screw density were similar in both groups. The mean preoperative major curves (MCs) were 57.6° and 62.5° in G1 and G2, respectively. The mean flexibility of the curves was noted as 35% in G1 and 33% in G2. After definitive surgery, the mean percentage correction of the MC was better in G2 vs. G1, with 74.5% vs. 69.8%, respectively (p < 0.001). At the final FU, the average loss of correction was 5.9° for G1 and 3.2° for G2 (p < 0.001). The mean preoperative (TK) thoracic kyphosis (T2-T5) was 12.2° in G1 and 10.8° in G2. It was corrected to 15.2° in G1 and to 13° in G2. At the FFU, we noted a significant difference in the TK (T2-T5) between the groups, with 16.7° vs. 9.6° for G1 vs. G2, respectively (p < 0.001). Statistical significance was observed between the preoperative sagittal balance and the final follow-up for both groups (p < 0.001). Conclusions: AIS patients surgically treated with screws with a larger diameter and thicker and stiffer rods showed greater correction and postoperative thoracic kyphosis without implant failure. The complication rates, implant density, and clinical outcomes remained similar. The radiographic benefits reported in this cohort study suggest that large-sized screws and stiffer rods for the correction of pediatric spinal deformities are safe and very effective.

10.
Malays Orthop J ; 18(1): 106-115, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38638653

RESUMO

Introduction: To compare post-operative outcomes of percutaneous pedicle screw fixation (PPSF) vs open pedicle screw fixation (OPSF) in patients with thoracolumbar spine fractures with no neurological deficits. Materials and methods: In a randomised controlled trial, patients received short-segment fixation with intermediate screws. We assessed post-operative back pain (Visual Analog Scale or VAS), blood loss, operative/fluoroscopy times, radiographic parameters, and oswestry disability index (ODI) scores at 1, 2, 3, 6, 9, and 12 months. Results: Between January 2018 and October 2019, 31 patients received PPSF and 30 OPSF. Mean intra-operative blood loss was 66.45 (±44.29) ml for PPSF vs 184.83 (±128.36) ml for OPSF (p<0.001). Fluoroscopy time averaged 2.36 (±0.76) minutes for PPSF vs 0.58 (±0.51) minutes for OPSF (p<0.001). No significant differences existed in operative time or post-operative VAS scores. Radiographic parameters (kyphosis angle and vertebral height ratios) didn't significantly differ post-operatively or at 12 months. However, ODI scores differed significantly at 6 months (p=0.025), with no difference at 12 months. Conclusion: In this trial, PPSF was comparable to OPSF in improving ODI scores at 12 months but showed earlier improvement at 6 months and reduced blood loss. Radiographic outcomes remained similar between groups over 12 months.

11.
Spine Deform ; 12(4): 989-1000, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38558382

RESUMO

PURPOSE: Hypoplastic pedicles of the thoracolumbar spine (<5 mm diameter) are often found in syndromic deformities of the spine and pose a challenge in pedicle screw instrumentation. 3D-printed patient-specific guides might help overcome anatomical difficulties when instrumenting pedicles with screws, thereby reducing the necessity for less effective fixation methods such as hooks or sublaminar wires. In this study, the surgical feasibility and clinical outcome of patients with hypoplastic pedicles following pedicle screw instrumentation with 3D-printed patient-specific guides were assessed. METHODS: Hypoplastic pedicles were identified on preoperative computed tomography (CT) scans in six patients undergoing posterior spinal fusion surgery between 2017 and 2020. Based on these preoperative CT scans, patient-specific guides were produced to help with screw instrumentation of these thin pedicles. Postoperatively, pedicle-screw-related complications or revisions were analyzed. RESULTS: 93/105 (88.6%) pedicle screws placed with patient-specific guides were instrumented. 62/93 (66.7%) of these instrumented pedicles were defined as hypoplastic with a mean width of 3.07 mm (SD ±0.98 mm, 95% CI [2.82-3.32]). Overall, 6 complications in the 62 hypoplastic pedicles (9.7%) were observed and included intraoperatively managed 4 cerebrospinal fluid leaks, 1 pneumothorax and 1 delayed revision due to 2 lumbar screws (2/62, 3.3%) impinging the L3 nerve root causing a painful radiculopathy. The mean follow-up time was 26.7 (SD ±11.7) months. Complications were only noted when the pedicle-width-to-screw-diameter ratio measured less than 0.62. CONCLUSION: Patient-specific 3D-printed guides can aid in challenging instrumentation of hypoplastic pedicles in the thoracolumbar spine, especially if the pedicle-width-to-screw-diameter ratio is greater than 0.62.


Assuntos
Parafusos Pediculares , Impressão Tridimensional , Fusão Vertebral , Vértebras Torácicas , Humanos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Masculino , Feminino , Vértebras Torácicas/cirurgia , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Adolescente , Estudos de Viabilidade , Adulto , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia
12.
Spine Deform ; 12(4): 909-921, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38573487

RESUMO

BACKGROUND: Adolescent idiopathic scoliosis (AIS) affects 1-3% of adolescents, and treatment approaches, including the density of constructs in surgical fusion, vary among orthopedic surgeons. Studies have sought to establish whether high-density or low-density constructs offer superior clinical and radiological outcomes, yet conclusive results are lacking. This meta-analysis aims to provide a definitive answer to the controversial and ambiguous question surrounding the efficacy of different pedicle screw densities in treating AIS. METHODS: PubMed, Cochrane, and Google Scholar (page 1-20) were searched till December 2023. The studied outcomes were Major Cobb angle, major curve correction, lumbar curve, kyphosis (T5-T12), lumbar lordosis, coronal balance, LIV Tilt angle, TAV translation, LAV translation, apical trunk rotation, trunk shift, SRS-22, operative time, blood loss, complications and cost. RESULTS: Twenty-four studies (total of 1985 patients, 1045 in LD group and 940 in HD group) were included in this meta-analysis. A statistically significant better improvement in ATR (p = 0.02) and LIV tilt angle (p = 0.02) was seen in the high-density group. On the other hand, longer operative time (p = 0.002), blood loss (p = 0.0004) and costs (p = 0.02) were seen in the high-density group. No difference was seen in the remaining radiographic and clinical outcomes between both surgeries. CONCLUSION: Both low-density (LD) and high-density (HD) screw constructs show comparable and satisfactory radiographic and QOL for AIS patients. Furthermore, HD constructs had increased costs, operative time, and blood loss associated. However, a definitive conclusion cannot be made and more studies taking into account multiple additional variables are necessary to do so.


Assuntos
Parafusos Pediculares , Escoliose , Fusão Vertebral , Humanos , Escoliose/cirurgia , Escoliose/diagnóstico por imagem , Adolescente , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Resultado do Tratamento , Duração da Cirurgia , Radiografia , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem
13.
J Neurosurg Spine ; 40(6): 733-740, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38457789

RESUMO

OBJECTIVE: Biomechanical factors in lumbar fusions accelerate the development of adjacent-segment disease (ASD). Stiffness in the fused segment increases motion in the adjacent levels, resulting in ASD. The objective of this study was to determine if there are differences in the reoperation rates for symptomatic ASD (operative ASD) between anterior lumbar interbody fusion plus pedicle screws (ALIF+PS), posterior lumbar interbody fusion plus pedicle screws (PLIF+PS), transforaminal lumbar interbody fusion plus pedicle screws (TLIF+PS), and lateral lumbar interbody fusion plus pedicle screws (LLIF+PS). METHODS: A retrospective study using data from the Kaiser Permanente Spine Registry identified an adult cohort (≥ 18 years old) with degenerative disc disease who underwent primary lumbar interbody fusions with pedicle screws between L3 to S1. Demographic and operative data were obtained from the registry, and chart review was used to document operative ASD. Patients were followed until operative ASD, membership termination, the end of study (March 31, 2022), or death. Operative ASD was analyzed using Cox proportional hazards models. RESULTS: The final study population included 5291 patients with a mean ± SD age of 60.1 ± 12.1 years and a follow-up of 6.3 ± 3.8 years. There was a total of 443 operative ASD cases, with an overall incidence rate of reoperation for ASD of 8.37% (95% CI 7.6-9.2). The crude incidence of operative ASD at 5 years was the lowest in the ALIF+PS cohort (7.7%, 95% CI 6.3-9.4). In the adjusted models, the authors failed to detect a statistical difference in operative ASD between ALIF+PS (reference) versus PLIF+PS (HR 1.06 [0.79-1.44], p = 0.69) versus TLIF+PS (HR 1.03 [0.81-1.31], p = 0.83) versus LLIF+PS (HR 1.38 [0.77-2.46], p = 0.28). CONCLUSIONS: In a large cohort of over 5000 patients with an average follow-up of > 6 years, the authors found no differences in the reoperation rates for symptomatic ASD (operative ASD) between ALIF+PS and PLIF+PS, TLIF+PS, or LLIF+PS.


Assuntos
Degeneração do Disco Intervertebral , Vértebras Lombares , Reoperação , Fusão Vertebral , Humanos , Reoperação/estatística & dados numéricos , Fusão Vertebral/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Vértebras Lombares/cirurgia , Degeneração do Disco Intervertebral/cirurgia , Parafusos Pediculares , Adulto , Idoso , Complicações Pós-Operatórias/epidemiologia
14.
World Neurosurg ; 185: e1321-e1329, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38521226

RESUMO

OBJECTIVE: This study aimed to quantify the change in pressure on the cage during compression manipulation in lumbar interbody fusion. While the procedure involves applying compression between pedicle screws to press the cage against the endplate, the exact compression force remains elusive. We hypothesize that an intact facet joint might serve as a fulcrum, potentially reducing cage pressure. METHODS: Pressure on the intervertebral disc cage was measured during compression manipulation in 4 donor cadavers undergoing lumbar interbody fusion. Unilateral facetectomy models with both normal and parallel compression and bilateral facetectomy models were included. A transforaminal lumbar interbody fusion cage with a built-in load cell measured the compression force. RESULTS: Pressure data from 14 discs indicated a consistent precompression pressure average of 68.16 N. Following compression, pressures increased to 125.99 N and 140.84 N for normal and parallel compression postunilateral facetectomy, respectively, and to 154.58 N and 150.46 N for bilateral models. A strong linear correlation (correlation coefficient: 0.967, P < 0.0001) between precompression and postcompression pressures emphasized the necessity of sufficient precompression pressure for achieving desired postcompression outcomes. None of the data showed a decrease in compression force to the cage with the compression maneuver. CONCLUSIONS: Both normal and parallel compression maneuvers effectively increased the pressure on the cage, irrespective of the facet joint resection status. Compression manipulation consistently enhanced compressive force on the cage. However, when baseline pressure is low, the manipulation might not yield significant increases in compression force. This underlines the essential role of meticulous precompression preparation in enhancing surgical outcomes.


Assuntos
Cadáver , Disco Intervertebral , Vértebras Lombares , Pressão , Fusão Vertebral , Humanos , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Vértebras Lombares/cirurgia , Disco Intervertebral/cirurgia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Fenômenos Biomecânicos/fisiologia , Parafusos Pediculares , Articulação Zigapofisária/cirurgia
15.
Cureus ; 16(3): e55768, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38463404

RESUMO

INTRODUCTION:  Surgical correction of adolescent idiopathic scoliosis (AIS) using the facetectomy technique with the utilization of segmental pedicle screws aims to achieve correction of coronal and sagittal imbalances and preserve normal neurological function. In this study, we aimed to certify the effectiveness of the facetectomy technique in the correction of AIS by analyzing technique outcomes. METHODS: This is a retrospective, single-center study. From January 2018 to March 2022, a total of 51 patients with AIS who underwent inferior facetectomy with segmental pedicle screw constructs at the Royal Rehabilitation Center were reviewed. Radiological parameters including the major curve Cobb angle, and global coronal balance were evaluated preoperatively, postoperatively, and at the final follow-up. Surgical parameters and complications were also reported. RESULTS: The mean major curve Cobb angle was 59.5 ± 4.9° preoperatively, 13.6 ± 2.7° postoperatively, and 14.5 ± 2.6° at the final follow-up, with correction rates of 77.2% and 75.7%, respectively. The mean global coronal balance was 2.7 ± 1.1 cm preoperatively, 1.7 ± 0.73 cm postoperatively, and 1.4 ± 0.55 cm at the final follow-up. Two cases of pleural injuries were reported intraoperatively. Postoperatively, two cases experienced superficial wound infections, one experienced pulmonary embolism, and one patient had revision surgery due to the loosening of a single screw. None of these complications lasted long. CONCLUSIONS: When combined with posterior segmental pedicle screw constructs, inferior facetectomy can provide an effective rate of correction in a reasonably safe manner.

16.
J Neurosci Rural Pract ; 15(1): 34-41, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476412

RESUMO

Objectives: The treatment options for thoracolumbar junction burst fractures remain a topic of controversy. Short-segment percutaneous fixation (SSPF) and short-segment open fixation including the fractured level (SSOFIFL) are both viable procedures for managing these fractures. At present, there is a lack of evidence in the literature demonstrating the absolute superiority of one treatment over the other. This study aimed to compare these two surgical strategies with a focus on radiological and clinical outcomes. Materials and Methods: This retrospective case-control multicenter analysis involved patients with A3 and A4 vertebral fractures at the thoracolumbar junction (T11-L2) who underwent surgical treatment with either SSPF or SSOFIFL in the participating centers. Clinical outcomes were measured using the Oswestry Disability Index and visual analogue scale (VAS) both pre- and postoperatively. Radiological outcomes included kyphotic deformity (KD), anterior vertebral body height (AVBH), segmental kyphosis, and sagittal alignment parameters. Results: A total of 156 patients were enrolled in the study, with 81 patients in Group A (SSPF) and 75 patients in Group B (SSOFIFL). Group B demonstrated better correction of KD (Group B: 3.4 ± 2.7° vs. Group A: 8.3 ± 3.2°, P = 0.003), AVBH, and sagittal alignment. A minor loss of correction was observed in Group B with respect to Group A (0.9 ± 1.7° vs 4.3° ± 2.1°, P = 0.043). Blood losses were lower in Group A (78 ± 15 min vs. 118 ± 23 min, P = 0.021) as well as during surgery (121.3 ± 34 mL vs. 210.2 ± 52 mL, P = 0.031), but the post-operative hemoglobin levels were comparable between the two groups. Conclusion: SSOFIFL appears to show a major amount of KD correction and prevent loss of correction. This technique should be the preferred choice whenever possible. However, SSPF can be considered a valid alternative for damage control in polytrauma patients and fractures with low KD.

17.
Neuroradiology ; 66(5): 855-863, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38453715

RESUMO

PURPOSE: To assess the feasibility and technical accuracy of performing pedicular screw placement combined with vertebroplasty in the radiological setting. METHODS: Patients who underwent combined vertebroplasty and pedicle screw insertion under combined computed tomography and fluoroscopic guidance in 4 interventional radiology centers from 2018 to 2023 were retrospectively assessed. Patient demographics, vertebral lesion type, and procedural data were analyzed. Strict intra-pedicular screw positioning was considered as technical success. Pain score was assessed according to the Visual Analogue Scale before the procedure and in the 1-month follow-up consultation. RESULTS: Fifty-seven patients (38 men and 19 women) with a mean age of 72.8 (SD = 11.4) years underwent a vertebroplasty associated with pedicular screw insertion for the treatment of traumatic fractures (29 patients) and neoplastic disease (28 patients). Screw placement accuracy assessed by post-procedure CT scan was 95.7% (89/93 inserted screws). A total of 93 pedicle screw placements (36 bi-pedicular and 21 unipedicular) in 32 lumbar, 22 thoracic, and 3 cervical levels were analyzed. Mean reported procedure time was 48.8 (SD = 14.7) min and average injected cement volume was 4.4 (SD = 0.9) mL. A mean VAS score decrease of 5 points was observed at 1-month follow-up (7.7, SD = 1.3 versus 2.7, SD = 1.7), p < .001. CONCLUSION: Combining a vertebroplasty and pedicle screw insertion is technically viable in the radiological setting, with a high screw positioning accuracy of 95.7%.


Assuntos
Parafusos Pediculares , Fraturas da Coluna Vertebral , Vertebroplastia , Masculino , Humanos , Feminino , Idoso , Estudos Retrospectivos , Estudos de Viabilidade , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Vértebras Lombares/cirurgia , Vertebroplastia/métodos
18.
Cureus ; 16(1): e53120, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38420078

RESUMO

Extension of existing spinal fusions may necessitate the removal of or linkage to prior constructs. Knowledge of previously placed instrumentation is critical to success in these revision scenarios. The Luque spinal instrumentation system, developed in the late 1980s, is a legacy pedicle screw and plate system that may be encountered during revision operations today. A 67-year-old male with a remote history of L4-S1 fusion with Luque instrumentation presented with bilateral lower extremity neurogenic claudication due to adjacent segment disease at L3-4. Decompression and extension of fusion to the L3-4 level were performed using minimally invasive techniques. Of note, posterior instrumentation was extended by removing prior L4 pedicle screws with a 7 mm female hexagonal driver through tubular retractors, leaving the Luque plates in place, placing modern pedicle screws at L4 (through the plates) and L3, and linking these with standard rods. The surgery and post-operative course were uncomplicated, and the patient experienced complete resolution of his pre-operative claudication symptoms. Extension of prior Luque plate instrumented fusion can be accomplished minimally invasively without removing the plates themselves, resulting in greater operative efficiency and less surgical morbidity.

19.
Global Spine J ; : 21925682241232328, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38324511

RESUMO

STUDY DESIGN: Human Cadaveric Study. OBJECTIVE: This study aims to explore the feasibility of using preoperative magnetic resonance imaging (MRI), zero-time-echo (ZTE) and spoiled gradient echo (SPGR), as source data for robotic-assisted spine surgery and assess the accuracy of pedicle screws. METHODS: Zero-time-echo and SPGR MRI scans were conducted on a human cadaver. These images were manually post-processed, producing a computed tomography (CT)-like contrast. The Mazor X robot was used for lumbar pedicle screw-place navigating of MRI. The cadaver underwent a postoperative CT scan to determine the actual position of the navigated screws. RESULTS: Ten lumbar pedicle screws were robotically navigated of MRI (4 ZTE; 6 SPGR). All MR-navigated screws were graded A on the Gertzbein-Robbins scale. Comparing preoperative robotic planning to postoperative CT scan trajectories: The screws showed a median deviation of overall 0.25 mm (0.0; 1.3), in the axial plane 0.27 mm (0.0; 1.3), and in the sagittal plane 0.24 mm (0.0; 0.7). CONCLUSION: This study demonstrates the first successful registration of MRI sequences, ZTE and SPGR, in robotic spine surgery here used for intraoperative navigation of lumbar pedicle screws achieving sufficient accuracy, showcasing potential progress toward radiation-free spine surgery.

20.
J Pers Med ; 14(2)2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38392576

RESUMO

PURPOSE: We aim to compare radiation exposure and implant-related complications of the freehand (FH) technique versus intraoperative image-guided navigation (IN) for pedicle screw placement in adolescent idiopathic scoliosis (AIS) and estimate associated lifetime attributable cancer risks. METHODS: A retrospective analysis of prospectively collected data from 40 consecutive AIS patients treated with pedicle screw instrumentation using the FH technique was performed. The dose area product (DAP) and effective dose (ED) were calculated. Screw-related complications were analysed, and the age- and gender-specific lifetime attributable cancer risks were estimated. The results were compared to previously published data on IN used during surgery for AIS. RESULTS: There were no implant-related complications in our cohort. Implant density was 86.6%. The mean Cobb angle of the main curve was 75.2° (SD ± 17.7) preoperatively and 27.7° (SD ± 10.8) postoperatively. The mean ED of our cohort and published data for the FH technique was significantly lower compared to published data on the IN technique (p < 0.001). The risk for radiogenic cancer for our FH technique AIS cohort was 0.0014% for male patients and 0.0029% for female patients. Corresponding risks for IN were significantly higher (p < 0.001), ranging from 0.0071 to 0.124% and from 0.0144 to 0.253% for male and female patients, respectively. CONCLUSION: The routine use of intraoperative navigation in AIS surgery does not necessarily reduce implant-related complications but may increase radiation exposure to the patient.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...