Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Sci Rep ; 14(1): 6319, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491040

RESUMO

In a linac driven Free Electron Laser (FEL), the shot-to-shot and non-invasive monitoring of the electron bunch length is normally ensured by Bunch Compressor Monitors (BCMs). The bunch-length dependent signal of a BCM results from the detection and integration-over a given frequency band-of the temporal coherent enhancement of the radiation spectral energy emitted by the electron beam while experiencing a longitudinal compression. In this work, we present a method that permits to express the relative variation of the bunch length as a function of the relative statistical fluctuations of the BCM and charge signals. Furthermore, in the case of a BCM equipped with two detectors simultaneously operating in two distinct wavelength bands, the method permits an absolute determination of the electron bunch length. The proposed method is beneficial to a FEL. Thanks to it, the machine compression feedback can be tuned against the absolute measurement of the bunch length rather than a bunch-length dependent signal. In a CW-superconducting-linac driven FEL, it can offer the precious opportunity to implement a fully non-invasive and absolute diagnostics of the bunch length.

2.
Eur Biophys J ; 53(3): 123-131, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451329

RESUMO

We present a new phenomenon resulting from the interaction of magnetic beads with cancer cells in a laser trap formed on a slide containing a depression 16.5 mm in diameter and 0.78 mm of maximum depth. This phenomenon includes the apparent formation and expansion of a dark bubble that attracts and incinerates surrounding matter when it explodes, which leads to a plasma emitting intense radiation that has the appearance of a star on a microscopic scale. We have observed the star-like phenomenon for more than 4 years, and the intensity depends on the laser's power. Measuring the laser power of the dark bubble shows the entrapment of electromagnetic energy as it expands.


Assuntos
Imãs , Neoplasias , Lasers , Neoplasias/radioterapia
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 46(5): 555-559, 2022 Sep 30.
Artigo em Chinês | MEDLINE | ID: mdl-36254486

RESUMO

Electromagnetic compatibility testing of proton therapy system is different from that of traditional products in an anechoic chamber. It has high requirements on the division of sample composition, the understanding of applicable standards, the formulation of operation mode, the selection of test location, and the test of ambient noise. According to the requirements of GB 4824-2019 standard, the test method of radiation emission of proton therapy equipment was developed to provide reference advice for the industry, and the problems encountered in the actual test were studied.


Assuntos
Terapia com Prótons , Fenômenos Eletromagnéticos
4.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(5): 372-374, 2019 Sep 30.
Artigo em Chinês | MEDLINE | ID: mdl-31625340

RESUMO

By introducing the unqualified cases of radiation emission test of medical laser equipment, this paper analyses the causes of the problems and the corrective measures adopted, and analyses the effectiveness of the corrective measures. It is proposed that the design rules and rules related to radiation emission should be mastered from the input stage of product design and development, and the radiation emission problem should be considered and solved as soon as possible.


Assuntos
Terapia a Laser , Lasers , Luz , Desenho de Equipamento , Terapia a Laser/instrumentação
5.
World Neurosurg ; 122: e805-e811, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30391598

RESUMO

BACKGROUND: Visualization of the anatomy in minimally invasive surgery (MIS) of the spine is limited and dependent on radiographic imaging, leading to increased radiation exposure to patients and surgical staff. Ultra-low-radiation imaging (ULRI) with image enhancement is a novel technology that may reduce radiation in the operating room. The aim of this study was to compare radiation emission between standard-dose and ULRI fluoroscopy with image enhancement in patients undergoing MIS of the spine. METHODS: This study prospectively enrolled 60 consecutive patients who underwent lateral lumbar interbody fusion, lateral lumbar interbody fusion with percutaneous pedicle screws, or MIS transforaminal lumbar interbody fusion. Standard-dose fluoroscopy was used in 31 cases, and ULRI with image enhancement was used in 29 cases. All imaging emission and radiation doses were recorded. RESULTS: Radiation emission per level was significantly less with ULRI than with standard-dose fluoroscopy for lateral lumbar interbody fusion (36.4 mGy vs. 119.8 mGy, P < 0.001), per screw placed in lateral lumbar interbody fusion (15.4 mGy per screw vs. 47.1 mGy per screw, P < 0.001), and MIS transforaminal lumbar interbody fusion (24.4 mGy vs. 121.6 mGy, P = 0.003). These differences represented reductions in radiation emission of 69.6%, 67.3%, and 79.9%. Total radiation doses per case were also significantly decreased for the transpsoas approach by 68.8%, lateral lumbar interbody fusion with percutaneous pedicle screws by 65.8%, and MIS transforaminal lumbar interbody fusion by 81.0% (P ≤ 0.004). CONCLUSIONS: ULRI with image enhancement has the capacity to significantly decrease radiation emission in minimally invasive procedures without compromising visualization of anatomy or procedure safety.


Assuntos
Aumento da Imagem/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/prevenção & controle , Idoso , Estudos de Coortes , Feminino , Humanos , Aumento da Imagem/normas , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/normas , Neurocirurgiões/normas , Exposição Ocupacional/normas , Parafusos Pediculares/normas , Estudos Prospectivos , Exposição à Radiação/normas , Fusão Vertebral/métodos , Fusão Vertebral/normas
6.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-772481

RESUMO

By introducing the unqualified cases of radiation emission test of medical laser equipment, this paper analyses the causes of the problems and the corrective measures adopted, and analyses the effectiveness of the corrective measures. It is proposed that the design rules and rules related to radiation emission should be mastered from the input stage of product design and development, and the radiation emission problem should be considered and solved as soon as possible.


Assuntos
Desenho de Equipamento , Terapia a Laser , Lasers , Luz
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...