Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Arq. bras. oftalmol ; 87(3): e2021, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520219

RESUMO

ABSTRACT A 33-year-old male presented with unilateral subacute infectious keratitis 4 weeks after surgery. Corneal inflammation was resistant to standard topical antibiotic regimens. During diagnostic flap lifting and sampling, the corneal flap melted and separated. Through flap lifting, corneal scraping, microbiological diagnosis of atypical mycobacteria, and treatment with topical fortified amikacin, clarithromycin, and systemic clarithromycin, clinical improvement was achieved.


RESUMO Paciente do sexo masculino, 33 anos, apresentou ceratite infecciosa subaguda unilateral 4 semanas após a cirurgia. A inflamação da córnea foi resistente aos regimes de antibióticos tópicos padrão. A aba da córnea foi derretida e seccionada durante o levantamento e amostragem para diagnóstico. A melhora clínica só foi alcançada após levantamento do retalho, raspagem e diagnóstico microbiológico de micobactérias atípicas e tratamento com amicacina fortificada tópica, claritromicina e claritromicina sistêmica.

2.
Arq. bras. oftalmol ; 87(4): e2023, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1557099

RESUMO

ABSTRACT We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable biometric measurements. Therefore, we opted for corneal treatment and corneal surface regularization. Although we attempted to lift the flap and wash the interface initially, the procedure proved unsuccessful, thereby necessitating immediate flap amputation. Once the corneal surface was regularized in the seventh postoperative month, transepithelial photorefractive keratectomy was successfully performed to homogenize the ocular surface, thereby significantly improving the patient's corrected visual acuity and resolving monocular diplopia. The surface and corneal curvature stabilized by the fifth month after the procedure. Phacoemulsification was then performed along with the implantation of a toric monofocal lens, which was selected using an appropriate formula, resulting in an excellent uncorrected visual acuity.

3.
JMIR Form Res ; 7: e51798, 2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38153777

RESUMO

BACKGROUND: Refractive surgery research aims to optimally precategorize patients by their suitability for various types of surgery. Recent advances have led to the development of artificial intelligence-powered algorithms, including machine learning approaches, to assess risks and enhance workflow. Large language models (LLMs) like ChatGPT-4 (OpenAI LP) have emerged as potential general artificial intelligence tools that can assist across various disciplines, possibly including refractive surgery decision-making. However, their actual capabilities in precategorizing refractive surgery patients based on real-world parameters remain unexplored. OBJECTIVE: This exploratory study aimed to validate ChatGPT-4's capabilities in precategorizing refractive surgery patients based on commonly used clinical parameters. The goal was to assess whether ChatGPT-4's performance when categorizing batch inputs is comparable to those made by a refractive surgeon. A simple binary set of categories (patient suitable for laser refractive surgery or not) as well as a more detailed set were compared. METHODS: Data from 100 consecutive patients from a refractive clinic were anonymized and analyzed. Parameters included age, sex, manifest refraction, visual acuity, and various corneal measurements and indices from Scheimpflug imaging. This study compared ChatGPT-4's performance with a clinician's categorizations using Cohen κ coefficient, a chi-square test, a confusion matrix, accuracy, precision, recall, F1-score, and receiver operating characteristic area under the curve. RESULTS: A statistically significant noncoincidental accordance was found between ChatGPT-4 and the clinician's categorizations with a Cohen κ coefficient of 0.399 for 6 categories (95% CI 0.256-0.537) and 0.610 for binary categorization (95% CI 0.372-0.792). The model showed temporal instability and response variability, however. The chi-square test on 6 categories indicated an association between the 2 raters' distributions (χ²5=94.7, P<.001). Here, the accuracy was 0.68, precision 0.75, recall 0.68, and F1-score 0.70. For 2 categories, the accuracy was 0.88, precision 0.88, recall 0.88, F1-score 0.88, and area under the curve 0.79. CONCLUSIONS: This study revealed that ChatGPT-4 exhibits potential as a precategorization tool in refractive surgery, showing promising agreement with clinician categorizations. However, its main limitations include, among others, dependency on solely one human rater, small sample size, the instability and variability of ChatGPT's (OpenAI LP) output between iterations and nontransparency of the underlying models. The results encourage further exploration into the application of LLMs like ChatGPT-4 in health care, particularly in decision-making processes that require understanding vast clinical data. Future research should focus on defining the model's accuracy with prompt and vignette standardization, detecting confounding factors, and comparing to other versions of ChatGPT-4 and other LLMs to pave the way for larger-scale validation and real-world implementation.

4.
Cell J ; 25(4): 217-221, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37210641

RESUMO

OBJECTIVE: Recent studies imply extensive applications for the human amniotic membrane (hAM) and its extract in medicine and ophthalmology. The content of hAM meets many requirements in eye surgeries, such as refractive surgery as the most important and commonly used method for treating the dramatically increasing refractive errors. However, they are associated with complications such as corneal haziness and corneal ulcer. This study was designed to evaluate the impact of amniotic membrane extracted eye drop (AMEED) on Trans-PRK surgery complications. MATERIALS AND METHODS: This randomized controlled trial was performed during two years (July 1, 2019-September 1, 2020). Thirty-two patients (64 eyes), including 17 females and 15 males, aged 20 to 50 years (mean age of 29.59 ± 6.51) with spherical equivalent between -5 to -1.5 underwent Trans Epithelial Photorefractive Keratectomy (Trans-PRK) surgery. One eye was selected per case (case group) and the other eye was considered as control. Randomization was done using the random allocation rule. The case group was treated with AMEED, and the artificial tear drop every 4 hours. The control eyes received artificial tear drops instilled every 4 hours. The evaluation continued for three days after the Trans-PRK surgery. RESULTS: A significant decrease in CED size was found in the AMEED group on the second day after surgery (P=0.046). Also, this group had a substantial reduction in pain, hyperemia, and haziness. CONCLUSION: This study showed that AMEED drop can increase the healing rate of corneal epithelial lesions after Trans- PRK surgery and reduce the early and late complications of Trans-PRK surgery. Researchers and Ophthalmologists should consider AMEED as a selection in patients with persistent corneal epithelial defects and patients who have difficulty in corneal epithelial healing. We understood AMEED has a different effect on the cornea after surgery; therefore, the researcher must know AMEED's exact ingredients and help expand AMEED uses (registration number: TCTR20230306001).

5.
Arq. bras. oftalmol ; 86(1): 38-45, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403477

RESUMO

ABSTRACT Purpose: The aim of this study was to evaluate the fitting process of a scleral lens that allows several parameter adjustments during trials and after the initial period of use. In addition, we verified which adjustments were needed and used the most, their indications, and how often these resources were used, and checked the results. Methods: Scleral contact lens fittings in a private clinic setting were prospectively analyzed in a sequential, non-randomized, and non-comparative manner. All the patients underwent a complete ophthalmic examination and had an indication for scleral lens use (Zenlens, Alden Optical). Results: Scleral fit was analyzed in 80 eyes of 45 patients. Regarding diagnosis, 72% of the patients had keratoconus; 12%, radial keratotomy; 5%, post-refractive surgery ectasia; 5%, dry eye; and 3%, high myopia. In 66 (82.5%) of the 80 eyes studied, parameters were modified when the lenses were ordered. The reasons that led to the modifications were apical touch or decreased sagittal height, increased sagittal height, cylindrical over-refraction, poor visual acuity, lens flexure, peripheral touch, 360° edge compression, horizontal edge compression, and vertical edge compression. Conclusion: In this study, the use of Zenlens scleral lenses was shown to be a promising corrective treatment for patients requiring the use of scleral lenses. Although the study suggests a learning curve, as many adjustments were allowed, the lens could be customized according to the patients' needs. This increased the success rates of fitting and wearing, and consequently, use of the lens became a great option for the visual rehabilitation of patients.


RESUMO Objetivo: Avaliar o processo de adaptação de uma lente escleral que permite vários ajustes de parâmetros durante os testes e após o período inicial do seu uso; verificar quais os ajustes foram necessários, quais foram os mais utilizados, as suas indicações, a frequência com que estes recursos foram utilizados, e avaliar os resultados das mudanças realizadas. Métodos: A adaptação da lente de contato escleral foi analisada prospectivamente, de forma sequencial, não aleatória e não comparativa. Todos os pacientes foram submetidos a um exame oftalmológico completo e tinham indicação para o uso de lentes esclerais. Foi utilizada a lente Zenlens (Alden Optical). Resultados: Foi analisada a adaptação de lentes de contato esclerais em 80 olhos de 45 pacientes. Quanto ao diagnóstico, 72% tinham ceratocone, 12% tinham sido submetidos a ceratotomia radial, 5% tinham ectasia pós-cirurgia refrativa, 5% tinham olho seco, e 3%, alta miopia. Em 66 dos 80 olhos estudados (82,5%), os parâmetros foram modificados quando as lentes foram encomendadas. As razões foram: toque apical ou diminuição da altura sagital, aumento da altura sagital, sobre-refração cilíndrica, baixa acuidade visual, flexão da lente, toque periférico, compressão da borda em 360° e compressão da borda horizontal e/ou vertical. Conclusão: O uso de lentes esclerais Zenlens demonstrou ser uma forma de correção muito promissora para os pacientes que requerem o uso de lentes esclerais. Embora o estudo sugira uma curva de aprendizagem, é possível personalizar as lentes de acordo com as necessidades de cada pacientes. Este fato melhora a adaptação e aumenta a chance de sucesso do uso.

6.
Rev. bras. oftalmol ; 82: e0006, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1423620

RESUMO

RESUMO Objetivo: Desenvolver e aplicar um questionário eletrônico para avaliação do conhecimento em cirurgia refrativa na população analisada. Métodos: Foi aplicado um questionário eletrônico a uma população composta de 840 participantes voluntários maiores de 18 anos. Resultados: A média da idade dos participantes foi 37,85 anos, sendo 60,1% do feminino. Dentre os participantes, 20,95% reportaram ter sido submetidos a alguma cirurgia ocular prévia, sendo 73,86% com objetivo refrativo. Entre estes, 73,08% mostraram-se satisfeitos/muito satisfeitos com o resultado. O critério mais importante na escolha de um cirurgião refrativo foi a indicação por um conhecido que realizara a cirurgia (43,81%). Destaca-se que os participantes submetidos à cirurgia refrativa discordaram que "a cirurgia é um procedimento simples e isento de riscos" mais do que as demais pessoas (p=0,0045) e também que "o objetivo principal da cirurgia é 'zerar' o grau" (p=0,0252). Conclusão: Nota-se a necessidade de melhorar o conhecimento pré-operatório da população sobre cirurgia refrativa e também de educação continuada para os oftalmologistas. Este estudo fomenta o desenvolvimento de novas ferramentas de educação com informações claras e de fácil acesso, que tenham caráter informativo, e não de convencimento.


ABSTRACT Objective: The purpose of this study was to develop and apply an online questionnaire to assess knowledge in Refractive Surgery in the analyzed population. Methods: An online questionnaire was applied to a population composed of 840 volunteer participants over 18 years of age. Results: The mean age of population was 37.85 years, of whom 60.1% were female. 20.95% of the participants reported having undergone previous eye surgery, 73.86% of which had a refractive objective. Among these, 73.08% were satisfied / very satisfied with the result. The most important criterion when choosing a refractive surgeon was the indication by a friend who underwent the procedure (43.81%). It is noteworthy that the participants who underwent refractive surgery disagreed more than the other people that "the surgery is a simple and risk-free procedure" (p = 0.0045) and that "the main objective of the surgery is to "zero" the diopter" (p = 0.0252). Conclusion: It is essential to improve population's preoperative knowledge about Refractive Surgery, as well as continuing education for ophthalmologists. Therefore, this study encourages the development of new education tools with clear and easily accessible information, which should be informative, and not convincing.

7.
Rev. bras. oftalmol ; 82: e0043, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1507881

RESUMO

ABSTRACT LASIK is a refractive surgical procedure in which a corneal flap is created to expose the corneal stromal bed. Preoperative estimation of corneal flap thickness is necessary to calculate the percentage tissue altered in LASIK, an important quantitative risk factor for ectasia. The objective of this study was to assess flap thickness and calculate percentage tissue altered to check if unexpectedly thicker flaps and higher percentage tissue altered could pose as risk factors of ectasia. Four subjects (eight eyes) were submitted to mechanical LASIK in 2009 and 2010. Pre and postoperative clinical and tomographic data were reviewed. Mean preoperative estimated percentage tissue altered was 39.18±1.31%, which was borderline for increased ectasia risk when considering the limit of 40%. However, when considering the postoperatively measured flap thickness, the actual mean percentage tissue altered turned out to be 45.17 ± 4.13%, which was significantly higher than predicted preoperatively (p=0.002). Unexpectedly higher postoperative percentage tissue altered may be responsible for corneal ectasia after mechanical LASIK.


RESUMO A LASIK é um procedimento cirúrgico refrativo, no qual um retalho corneano é criado para expor o leito estromal corneano. A estimativa pré-operatória da espessura do retalho corneano é necessária para calcular o percentual de tecido alterado no LASIK, um importante fator de risco quantitativo para ectasia. O objetivo deste estudo foi avaliar a espessura do retalho e calcular o percentual de tecido alterado para verificar se retalhos inesperadamente mais espessos e percentuais de tecido alterado mais altos poderiam representar fatores de risco de ectasia. Quatro indivíduos (oito olhos) foram submetidos à LASIK mecânica em 2009 e 2010. Dados clínicos e tomográficos pré e pós-operatórios foram revisados. A média de percentual de tecido alterado pré-operatória estimada foi de 39,18±1,31%, limítrofe para risco aumentado de ectasia quando considerado o limite de 40%. No entanto, ao considerar a espessura do retalho medida no pós-operatório, o percentual de tecido alterado médio real foi de 45,17±4,13%, ou seja, significativamente maior do que o previsto no pré-operatório (p=0,002). O percentual de tecido alterado pós-operatóriao inesperadamente mais alto pode ser responsável pela ectasia da córnea após LASIK mecânico.


Assuntos
Humanos , Masculino , Feminino , Adulto , Complicações Pós-Operatórias , Retalhos Cirúrgicos/patologia , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Dilatação Patológica/etiologia , Lasers de Excimer/efeitos adversos , Erros de Refração , Córnea/cirurgia , Córnea/patologia , Topografia da Córnea/métodos , Tomografia de Coerência Óptica , Dilatação Patológica/diagnóstico , Procedimentos Cirúrgicos Refrativos/métodos , Lasers de Excimer/uso terapêutico
8.
Indian J Ophthalmol ; 70(5): 1533-1537, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35502018

RESUMO

Purpose: Accurate refraction is arguably the most important parameter for a successful laser vision correction surgery and is based on a combination of manifest and cycloplegic refraction. Wavefront-based objective refraction may be useful in the evaluation of patients. So far, the reliability of objective refraction as measured using the Pentacam® AXL Wave has not been published in the literature. Methods: This was a prospective study including a total of 168 eyes belonging to 84 young non-presbyopic patients evaluated for refractive surgery. Pentacam® AXL Wave full sequence was taken for all patients. Then, a clinician who was unaware of the objective refraction results performed a full physical examination, including manifest refraction starting from an autorefractometer value. All refraction values were transferred to astigmatic power vectors as per the Thibos method. Reliability of the different vectors and a unifying blur value were compared using Spearman correlation, Bland-Altman plot, and intraclass correlation coefficient. Results: The mean age was 28.8 ± 5.4 years, with a female preponderance (60.7%). The correlation between both eyes was high. The difference in M vector between subjective and objective refraction was 0.16 D, while the difference was 0.04 and 0.01 D for the J0 and J45 vectors, respectively. Paired samples Student t was non-significant for all comparisons. Spearman rho correlations were high (0.666-0.924, all P < 0.001). Intraclass correlation coefficients were also high (0.890-0.966). Bland-Altman plots did not demonstrate any systematic errors. Conclusion: Wavefront-based refractive refraction obtained using the Pentacam® AXL Wave is highly agreeable and correlated with measurements obtained by manifest subjective refraction.


Assuntos
Procedimentos Cirúrgicos Refrativos , Testes Visuais , Adulto , Feminino , Humanos , Estudos Prospectivos , Refração Ocular , Reprodutibilidade dos Testes , Testes Visuais/métodos , Adulto Jovem
9.
Taiwan J Ophthalmol ; 11(2): 113-121, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34295616

RESUMO

Refractive errors are the leading cause of reversible visual impairment worldwide. In addition to the desired spectacle independence, refractive procedures can improve quality of life, working ability, and daily working performance. Refractive corneal lenticule extraction (RCLE) is a relatively new technique, dependent only on a femtosecond laser (FS). This leads to potential benefits over laser-assisted in situ keratomileusis (LASIK) including a quicker recovery of dry eye disease, a larger functional optical zone, and no flap-related complications. SMILE, available with the VisuMax FS (Carl Zeiss Meditec AG, Jena, Germany), is the most established RCLE application, offering visual and refractive outcomes comparable to LASIK. SmartSight (SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany) and CLEAR (Ziemer Ophthalmic Systems AG, Port, Switzerland) are two new RCLE applications that received Conformité Européenne (CE) approval in 2020. In this article, we review refractive and visual outcomes, advantages, and disadvantages of RCLE and also report on the latest advances in RCLE systems.

10.
BMC Ophthalmol ; 21(1): 231, 2021 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-34034681

RESUMO

BACKGROUND: Intraocular lens (IOL) calculation using traditional formulas for post-corneal refractive surgery eyes can yield inaccurate results. This study aimed to compare the clinical accuracy of the newly developed Zhang & Zheng (ZZ) formula with previously reported IOL formulas. STUDY DESIGN: Retrospective study. METHODS: Post-corneal refractive surgery eyes were assessed for IOL power using the ZZ, Haigis-L, Shammas, Barrett True-K (no history), and ray tracing (C.S.O Sirius) IOL formulas, and their accuracy was compared. No pre-refractive surgery information was used in the calculations. RESULTS: This study included 38 eyes in 26 patients. ZZ IOL yielded a lower arithmetic IOL prediction error (PE) compared with ray tracing (P = 0.04), whereas the other formulas had values like that of ZZ IOL (P > 0.05). The arithmetic IOL PE for the ZZ IOL formula was not significantly different from zero (P = 0.96). ZZ IOL yielded a lower absolute IOL PE compared with Shammas (P < 0.01), Haigis-L (P = 0.02), Barrett true K (P = 0.03), and ray tracing (P < 0.01). The variance of the mean arithmetic IOL PE for ZZ IOL was significantly smaller than those of Shammas (P < 0.01), Haigis-L (P = 0.03), Barrett True K (P = 0.02), and ray tracing (P < 0.01). The percentages of eyes within ± 0.5 D of the target refraction with the ZZ IOL, Shammas, Haigis-L, Barrett True-K, and ray-tracing formulas were 86.8 %, 45.5 %, 66.7 %, 73.7 %, and 50.0 %, respectively (P < 0.05 for Shammas and ray tracing vs. ZZ IOL). CONCLUSIONS: The ZZ IOL formula might offer superior outcomes for IOL power calculation for post-corneal refractive surgery eyes without prior refractive data.


Assuntos
Lentes Intraoculares , Miopia , Facoemulsificação , Biometria , Humanos , Implante de Lente Intraocular , Miopia/cirurgia , Óptica e Fotônica , Refração Ocular , Estudos Retrospectivos
11.
Lasers Med Sci ; 36(1): 75-81, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32297251

RESUMO

This study aimed to compare the visual outcomes after photorefractive keratectomy (PRK), with and without the iris registration (IR) technology. The retrospective cohort study was performed for wavefront-guided PRK using the Technolas 217z100 excimer laser system in patients with myopic astigmatism (cylinder error - 2 to - 4 diopter [D]). Eyes were divided into IR group (IRPRK) and non-IR group (non-IRPRK). Visual acuity (VA), cylindrical refraction, and the astigmatic vector components using the Alpins method were compared between the two groups preoperatively and 6 months postoperatively. Fifty IRPRK patients (66% female, mean age 30.56 ± 6.31 years) and 50 non-IRPRK (60% female, mean age 29.60 ± 5.63 years) were enrolled. The mean logMAR uncorrected VA improved from 0.89 ± 0.44 to 0.032 ± 0.05 in the IRPRK group (P < 0.001) and from 0.89 ± 0.46 to 0.042 ± 0.06 postoperatively while follow-up in the non-IRPRK group (P < 0.001). No statistically significant differences were observed between the two groups regarding mean uncorrected distance VA (P = 0.4), corrected distance VA (P = 0.5), spherical equivalent (P = 0.16), defocus equivalent (P = 0.18), and absolute cylinder (P = 0.94). More than 90% eyes were within ± 1.00 D of emmetropia in both groups. Moreover, Alpins vector analysis revealed that no significant differences were found in any astigmatic parameters between the two groups (P > 0.05). Wavefront-guided PRK independent of the IR status is effective, safe, and predictable in patients with myopic astigmatism. No statistical significance was observed supporting data for the better outcome of visual acuity and astigmatism correction using IR in comparison with a non-IR system.


Assuntos
Astigmatismo/cirurgia , Iris/efeitos da radiação , Iris/cirurgia , Ceratectomia Fotorrefrativa , Adulto , Feminino , Humanos , Lasers de Excimer , Masculino , Ceratectomia Fotorrefrativa/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
12.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-908625

RESUMO

Refractive surgery is one of the important methods for refractive error correction, which include corneal refractive surgery and intraocular refractive surgery.In recent years, refractive surgery has a rapid development, and there is still development space and potential market demand.The clinical application of various new technologies has brought the refractive surgery to a new stage.The ultimate aim of refractive surgery is to pursue safer minimally invasive approaches and more customized correction for better visual quality.The new approaches including the guidance of corneal topography and wavefront aberration, the Q-value adjustment, Kappa angle adjustment, and customized corneal cross-linking during the surgery have been developed.The integration of various surgical approaches and research is also a new development direction.The combination with intelligent operation to improve the efficiency and accuracy of treatment seems to be one new direction, too.Ophthalmologists should pay attention to the current development and the possible future directions and trends of refractive surgery in China.

13.
Rom J Ophthalmol ; 64(2): 176-183, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32685784

RESUMO

Objective: To compare late mid-term results of two different surgical approaches of surface excimer laser ablation for myopic and astigmatic errors in contralateral eyes of the same patients. Methods: Prospective cohort study. A photorefractive keratectomy technique was performed on the right eye and single-step transepithelial photorefractive keratectomy on the left eye of the same patient, in 2012. Postoperative uncorrected and corrected visual acuities, manifest refraction, contrast sensitivity, objective scatter index, tear film stability assessed by serial measurements of objective scatter index and aberrometry as well as occurrence of haze, were compared between groups of eyes. Results: Thirty-two eyes of 16 patients with a mean time of follow-up of 35.2 +/ - 5.0 months (range 30-46 months) were evaluated. No significant differences were observed in postoperative results (visual acuity, spherical equivalent, defocus equivalent, higher-order aberrations, objective scatter index, tear film stability and contrast sensitivity). Contrast sensitivity tended to be better in transepithelial photorefractive keratectomy technique, under photopic lighting conditions without glare and mesopic conditions both with glare and without glare, however, no statistically significant differences were found. No eye presented corneal haze at the last examination. Conclusion: No statistically significant differences in visual acuity, refractive results, contrast sensitivity, objective scatter index, tear film stability or ocular aberrometry were observed between the two surface ablation techniques.


Assuntos
Córnea/cirurgia , Terapia a Laser/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Ceratectomia Fotorrefrativa/métodos , Refração Ocular/fisiologia , Acuidade Visual , Adulto , Sensibilidades de Contraste/fisiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Estudos Prospectivos , Adulto Jovem
14.
Korean J Ophthalmol ; 34(1): 76-84, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32037752

RESUMO

PURPOSE: To investigate clinical outcomes of small incision lenticule extraction (SMILE) including vector parameters and corneal aberrations in myopic patients. METHODS: This retrospective, observational case series included 57 eyes (29 patients) that received treatment for myopia using SMILE. Visual acuity measurement, manifest refraction, slit-lamp examination, autokeratometry, corneal topography, and evaluation of corneal wavefront aberration were performed preoperatively and at 1 and 3 months after surgery. We analyzed the safety, efficacy, vector parameters, and corneal aberrations at 3 months after surgery. RESULTS: Preoperatively, mean manifest refraction spherical equivalent refraction was -4.94 ± 1.94 D (range, -8.25 to 0 diopters [D]), and the cylinder was -1.14 ± 0.82 D (range, -3 to 0 D). Mean manifest refraction spherical equivalent improved to -0.10 ± 0.23 D at 3 months postoperatively, when uncorrected distance visual acuity was 20 / 20 or better in 55 (96%) eyes. The linear regression model of target induced astigmatism vector versus surgically induced astigmatism vector exhibited slopes and coefficients (R²) of 0.9618 and 0.9748, respectively (y = 0.9618x + 0.0006, R² = 0.9748). While total corneal root mean square higher order aberrations, coma and trefoil showed statistically significant increase, spherical aberration did not show statistically significant change after SMILE. CONCLUSIONS: SMILE has proven to be effective and safe for correcting myopia and astigmatism. We showed that SMILE did not induce spherical aberrations. A small increase in postoperative corneal higher order aberration may be associated with increase in coma and trefoil.


Assuntos
Córnea/patologia , Topografia da Córnea/métodos , Terapia a Laser/métodos , Miopia/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/métodos , Refração Ocular/fisiologia , Acuidade Visual , Adulto , Córnea/cirurgia , Aberrações de Frente de Onda da Córnea/diagnóstico , Feminino , Seguimentos , Humanos , Lasers de Excimer/uso terapêutico , Masculino , Microcirurgia/métodos , Pessoa de Meia-Idade , Miopia/diagnóstico , Miopia/fisiopatologia , Estudos Prospectivos , Estudos Retrospectivos , Adulto Jovem
15.
Zhonghua Yan Ke Za Zhi ; 56(2): 81-85, 2020 Feb 11.
Artigo em Chinês | MEDLINE | ID: mdl-32074816

RESUMO

Corneal refractive surgery in China, represented by laser corneal surgery, has undergone great changes in recent 30 years. Almost one million corneal refractive surgeries are performed each year. With the rapid technological innovation, the corrective effect is constantly higher, and complications are continuously controlled and reduced. The team of practitioners keeps expanding, and the academic strength is approaching the international level. With the application and promotion of various new technologies, the formulation of relevant norms and the increase of academic researches, corneal refractive surgery in China has stepped into the stage of diversification, intelligence and standardization. However, we should recognize the shortcomings while facing the great achievements. More efforts are still needed to provide the best visual quality and natural vision correction effect for patients. We would like to send congratulations on the 70th anniversary of Chinese Journal of Ophthalmology with this article. (Chin J Ophthalmol, 2020, 56: 81-85).


Assuntos
Miopia , Oftalmologia , Procedimentos Cirúrgicos Refrativos , China , Humanos , Miopia/cirurgia , Oftalmologia/tendências , Procedimentos Cirúrgicos Refrativos/tendências , Acuidade Visual
16.
Zhonghua Yan Ke Za Zhi ; 56(2): 110-117, 2020 Feb 11.
Artigo em Chinês | MEDLINE | ID: mdl-32074821

RESUMO

Objective: To investigate the influence factors and differences of abnormal posterior corneal elevation by Pentacam system and Corvis ST. Methods: This retrospective case series study included 227 eyes of 144 patients (90 males, 139 eyes; 54 females, 88 eyes) from December 2017 to October 2018 who were going to receive corneal refractive surgery at the Corneal Refraction Department of Qingdao Eye Hospital. The general data of the patients including gender, age, refractive parameters, optimal correction of spherical and cylindrical diopters were collected. All patients underwent Pentacam system and Corvis ST measurement. According to the back difference (BD) of Pentacam parameters, BD<12 µm was set as the control group (59 patients, 118 eyes) and BD≥12 µm as the high BD group (85 patients, 109 eyes). In the high BD group, BD≤16 µm was set as the suspicious group (44 patients, 53 eyes), while BD>16 µm was set as the abnormal group (41 patients, 56 eyes). Seven parameters of Pentacam and 15 parameters of Corvis ST were selected. The Pentacam parameters included BD, anterior surface keratometry (ASK), posterior surface keratometry (PSK), anterior surface astigmatism (AAstig), posterior surface astigmatism (PAstig), central corneal thickness (CCT), and corneal diameter (W-W). The parameters of Corvis ST included the first applanation time (AT(1)), the first applanation length (AL(1)), the first applanation velocity (AV(1)), the second applanation time (AT(2)), the second applanation length (AL(2)), the second applanation velocity (AV(2)), highest concavity time (HCT), highest concavity peak distance (HC-PD), highest concavity deformation amplitude (HC-DA), highest concavity radius (HC-R), the ratio of deformation amplitude (DA ratio), Integr. Radius, corneal thickness thinnest/pachymetric progression (ARTh), SPA1 (resultant pressure divided by deflection amplitude at the first applanation), and the Corvis Biomechanical Index (CBI). The comparison between the groups was analyzed with Independent sample t test, Kruskal-Wallis H test, and Bonferroni test. Spearman rank correlation analysis was used to explore the correlation factors of BD, and the main factors affecting BD were found through multiple linear regression. Results: There were no statistically significant differences between the control group and the high BD group in age, spherical diopters, and cylindrical diopters (t=-3.311, -1.808, -2.359; P=0.071, 0.072, 0.121, respectively). In Pentacam parameters, ASK, PSK, PAstig, and W-W showed significant differences among groups (Z=18.492, 31.547, 10.773, 70.167; P<0.05). AAstig and CCT showed no statistical difference between groups (P>0.05). Compared with the control group [42.80 (41.98, 44.00)], ASK increased in the abnormal group [43.40 (42.20, 44.40)] significantly (t=-4.292; P<0.05). PSK of the suspicious group [-6.50 (-6.60, -6.35)] and the abnormal group [-6.50 (-6.70, -6.33)] increased significantly compared with the control group [-6.30 (-6.50, -6.20)] (t=4.492, 4.618; P<0.05). Compared with the control group [0.40 (0.30, 0.50)], PAstig of the suspicious group [0.40 (0.30, 0.40)] and the abnormal group [0.40 (0.30, 0.40)] increased significantly (t=2.796, 2.515; P=0.016, 0.036). Compared with the control group [11.50 (11.40, 11.80)], W-W of the suspicious group [11.40 (11.00, 11.60)] and the abnormal group [11.10 (10.90, 11.30)] decreased, and W-W of the abnormal group also decreased significantly compared with the suspicious group (t=3.235, 8.353, 4.282; P<0.05). The correlation analysis between BD and Pentacam parameters of patients in each group showed that BD was negatively correlated with W-W (r=-0.614, -0.304, -0.396, -0.661, P<0.05) in the control group, the suspicious group, the abnormal group, and all patients, while BD had a low correlation with other parameters or no significant correlation. The correlation analysis of BD and Corvis ST parameters in patients showed that only in the suspicious group, BD was positively correlated with AV(1), HCT, and HC-DA (r=0.332, 0.361, 0.382, P<0.05), while no significant correlation was found between BD and other Corvis ST parameters in each group. In order to further explore the main factors affecting BD, Pentacam parameters and Corvis ST parameters were selected as independent variables with BD as the dependent variable to establish a multivariate linear regression analysis model. There was no collinearity between variables W-W, ASK, PSK, HC-PD, SPA1, and CCT (tolerance<0.100). The equation test result was F=37.221, P<0.001, adjusted r(2)=0.504, and the fitting was good. Conclusions: Among the Pentacam parameters, W-W, ASK, and PSK are the main factors affecting the change of BD. HC-PD and SPA1 in the Corvis ST parameters may also have some influence on BD. The Pentacam system combined with Corvis ST is a very useful differential diagnosis system for patients with abnormal BD. (Chin J Ophthalmol, 2020, 56:110-117).


Assuntos
Córnea , Pressão Intraocular , Tonometria Ocular , Fenômenos Biomecânicos , Córnea/anormalidades , Feminino , Humanos , Masculino , Estudos Retrospectivos
17.
Arq. bras. oftalmol ; 83(1): 65-68, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1088960

RESUMO

ABSTRACT We describe a case of keratomycosis caused by Arthographis kalrae after excimer laser keratomileusis. A 38-year-old female developed stromal keratitis eight weeks after refractive surgery. She developed severe corneal stromal infiltration and mild anterior segment inflammation, which could not be treated with topical voriconazole 1%, but topical natamycin 5% ameliorated her condition. A reactivation of keratomycosis symptoms was observed; therefore, longer treatment was administered to the patient. It has been reported that A. kalrae keratomycosis is associated with exposure to soil and contact lens usage. However, the patient, who lived in a rural location, was neither involved in gardening activities nor had a history of wearing contact lenses. This is the first case of post-refractive A. kalrae keratomycosis.


RESUMO Descrevemos um caso de ceratomicose por Arthographis kalrae após ceratomileusis por excimer laser. Uma mulher de 38 anos desenvolveu ceratite estromal oito semanas após a cirurgia refrativa. Ela desenvolveu infiltração estromal grave da córnea e uma leve inflamação do segmento anterior, que não pode ser tratada com voriconazol tópico a 1%, mas a natamicina tópica a 5% melhorou sua condição. Uma reativação dos síntomas de ceratomicose foi observada; portanto, tratamento mais prolongado foi administrado a paciente. Tem sido relatado que a ceratomicose por A. kalrae está associada à exposição ao solo e ao uso de lentes de contato. No entanto, a paciente, que vivía em um local rural, não estava envolvida em atividades de jardinagem e nem tinha histórico de uso de lentes de contato. Este é o primeiro caso de ceratomicose pós-refrativa por A. kalrae.


Assuntos
Humanos , Feminino , Adulto , Infecções Oculares Fúngicas/microbiologia , Ceratite/microbiologia , Ascomicetos/isolamento & purificação , Infecções Oculares Fúngicas/tratamento farmacológico , Natamicina/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Voriconazol/uso terapêutico , Ceratite/tratamento farmacológico
18.
Arq. bras. oftalmol ; 83(1): 76-81, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1088947

RESUMO

ABSTRACT The point of centration for refractive surgery is a theme of great importance that generates considerable discussion among specialists and surgeons in the field. Notably, any changes in light can alter the size of the pupil, and the visual axis of the fixation line to the fovea is unique in each patient. A variety of options have been described in the literature with respect to centration in refractive surgery, and the results differ among these methods. No consensus has been established regarding the ideal refractive surgery technique for evaluation of centration in each patient that will yield a satisfactory surgical result.


RESUMO O ponto de centralização da cirurgia refrativa é tema de grande importância e gera muita discussão entre especialistas e cirurgiões da área. Afinal, qualquer alteração na luz pode alterar o tamanho da pupila, além disso, o eixo visual da linha de fixação para a fóvea é particular em cada paciente. Existem opções para centralização em cirurgia refrativa com resultados diferentes na literatura. Ainda não há consenso sobre a melhor técnica em cirurgia refrativa que avalie cada caso específico visando um resultado cirúrgico final satisfatório.


Assuntos
Humanos , Pupila/fisiologia , Córnea/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer , Refração Ocular , Córnea/patologia , Fixação Ocular
19.
J Fr Ophtalmol ; 43(1): 67-79, 2020 Jan.
Artigo em Francês | MEDLINE | ID: mdl-31780331

RESUMO

Corneal surface analysis is now more and more accurate. Corneal topography is a gold standard in corneal pathology follow-up: keratoconus, corneal grafts, orthokeratology. In refractive surgery, cornea ectasia post-Lasik must be avoided. Analyzing anterior and posterior surface can detect forme fruste keratoconus FFKC. Topography allows also better predictability of premium intraocular implants surgery. Topography is key examination and its interpretation is essential.


Assuntos
Doenças da Córnea/diagnóstico , Topografia da Córnea , Padrões de Prática Médica , Córnea/diagnóstico por imagem , Córnea/patologia , Doenças da Córnea/patologia , Doenças da Córnea/terapia , Topografia da Córnea/métodos , Topografia da Córnea/estatística & dados numéricos , Topografia da Córnea/tendências , Transplante de Córnea/efeitos adversos , Transplante de Córnea/métodos , Humanos , Ceratocone/diagnóstico , Ceratocone/patologia , Ceratocone/terapia , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Implante de Lente Intraocular/efeitos adversos , Implante de Lente Intraocular/métodos , Monitorização Fisiológica/métodos , Padrões de Prática Médica/normas , Padrões de Prática Médica/estatística & dados numéricos , Padrões de Prática Médica/tendências , Acuidade Visual
20.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-865230

RESUMO

Although binocular vision problems do not appear to be one of the common complications of refractive surgery,the available evidence suggests that these problems can occur after refractive surgery,and preoperative binocular vision status may predict the risk of postoperative binocular vision anomalies.Furthermore,because ophthalmologists usually do not clearly recognize binocular vision,or they do not pay enough attention to it,the existing literature may underestimate the actual prevalence of binocular vision problems after refractive surgery.This paper discusses the existing literature on refractive surgery-related binocular vision anomalies and recommends a screening protocol and risk stratification.It also discusses the expected results of binocular vision testing,the diagnostic criteria for common binocular vision problems,and strategies for treating these anomalies before and after refractive surgery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...