Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.919
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38948964

RESUMO

BACKGROUND: Identifying language disorders earlier can help children receive the support needed to improve developmental outcomes and quality of life. Despite the prevalence and impacts of persistent language disorder, there are surprisingly no robust predictor tools available. This makes it difficult for researchers to recruit young children into early intervention trials, which in turn impedes advances in providing effective early interventions to children who need it. AIMS: To validate externally a predictor set of six variables previously identified to be predictive of language at 11 years of age, using data from the Longitudinal Study of Australian Children (LSAC) birth cohort. Also, to examine whether additional LSAC variables arose as predictive of language outcome. METHODS & PROCEDURES: A total of 5107 children were recruited to LSAC with developmental measures collected from 0 to 3 years. At 11-12 years, children completed the Clinical Evaluation of Language Fundamentals, 4th Edition, Recalling Sentences subtest. We used SuperLearner to estimate the accuracy of six previously identified parent-reported variables from ages 2-3 years in predicting low language (sentence recall score ≥ 1.5 SD below the mean) at 11-12 years. Random forests were used to identify any additional variables predictive of language outcome. OUTCOMES & RESULTS: Complete data were available for 523 participants (52.20% girls), 27 (5.16%) of whom had a low language score. The six predictors yielded fair accuracy: 78% sensitivity (95% confidence interval (CI) = [58, 91]) and 71% specificity (95% CI = [67, 75]). These predictors relate to sentence complexity, vocabulary and behaviour. The random forests analysis identified similar predictors. CONCLUSIONS & IMPLICATIONS: We identified an ultra-short set of variables that predicts 11-12-year language outcome with 'fair' accuracy. In one of few replication studies of this scale in the field, these methods have now been conducted across two population-based cohorts, with consistent results. An imminent practical implication of these findings is using these predictors to aid recruitment into early language intervention studies. Future research can continue to refine the accuracy of early predictors to work towards earlier identification in a clinical context. WHAT THIS PAPER ADDS: What is already known on the subject There are no robust predictor sets of child language disorder despite its prevalence and far-reaching impacts. A previous study identified six variables collected at age 2-3 years that predicted 11-12-year language with 75% sensitivity and 81% specificity, which warranted replication in a separate cohort. What this study adds to the existing knowledge We used machine learning methods to identify a set of six questions asked at age 2-3 years with ≥ 71% sensitivity and specificity for predicting low language outcome at 11-12 years, now showing consistent results across two large-scale population-based cohort studies. What are the potential or clinical implications of this work? This predictor set is more accurate than existing feasible methods and can be translated into a low-resource and time-efficient recruitment tool for early language intervention studies, leading to improved clinical service provision for young children likely to have persisting language difficulties.

2.
Eur Radiol Exp ; 8(1): 79, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38965128

RESUMO

Sample size, namely the number of subjects that should be included in a study to reach the desired endpoint and statistical power, is a fundamental concept of scientific research. Indeed, sample size must be planned a priori, and tailored to the main endpoint of the study, to avoid including too many subjects, thus possibly exposing them to additional risks while also wasting time and resources, or too few subjects, failing to reach the desired purpose. We offer a simple, go-to review of methods for sample size calculation for studies concerning data reliability (repeatability/reproducibility) and diagnostic performance. For studies concerning data reliability, we considered Cohen's κ or intraclass correlation coefficient (ICC) for hypothesis testing, estimation of Cohen's κ or ICC, and Bland-Altman analyses. With regards to diagnostic performance, we considered accuracy or sensitivity/specificity versus reference standards, the comparison of diagnostic performances, and the comparisons of areas under the receiver operating characteristics curve. Finally, we considered the special cases of dropouts or retrospective case exclusions, multiple endpoints, lack of prior data estimates, and the selection of unusual thresholds for α and ß errors. For the most frequent cases, we provide example of software freely available on the Internet.Relevance statement Sample size calculation is a fundamental factor influencing the quality of studies on repeatability/reproducibility and diagnostic performance in radiology.Key points• Sample size is a concept related to precision and statistical power.• It has ethical implications, especially when patients are exposed to risks.• Sample size should always be calculated before starting a study.• This review offers simple, go-to methods for sample size calculations.


Assuntos
Projetos de Pesquisa , Tamanho da Amostra , Humanos , Reprodutibilidade dos Testes
3.
Diagnostics (Basel) ; 14(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38893592

RESUMO

Patients diagnosed with glioblastoma multiforme (GBM) continue to face a dire prognosis. Developing accurate and efficient contouring methods is crucial, as they can significantly advance both clinical practice and research. This study evaluates the AI models developed by MRIMath© for GBM T1c and fluid attenuation inversion recovery (FLAIR) images by comparing their contours to those of three neuro-radiologists using a smart manual contouring platform. The mean overall Sørensen-Dice Similarity Coefficient metric score (DSC) for the post-contrast T1 (T1c) AI was 95%, with a 95% confidence interval (CI) of 93% to 96%, closely aligning with the radiologists' scores. For true positive T1c images, AI segmentation achieved a mean DSC of 81% compared to radiologists' ranging from 80% to 86%. Sensitivity and specificity for T1c AI were 91.6% and 97.5%, respectively. The FLAIR AI exhibited a mean DSC of 90% with a 95% CI interval of 87% to 92%, comparable to the radiologists' scores. It also achieved a mean DSC of 78% for true positive FLAIR slices versus radiologists' scores of 75% to 83% and recorded a median sensitivity and specificity of 92.1% and 96.1%, respectively. The T1C and FLAIR AI models produced mean Hausdorff distances (<5 mm), volume measurements, kappa scores, and Bland-Altman differences that align closely with those measured by radiologists. Moreover, the inter-user variability between radiologists using the smart manual contouring platform was under 5% for T1c and under 10% for FLAIR images. These results underscore the MRIMath© platform's low inter-user variability and the high accuracy of its T1c and FLAIR AI models.

4.
J Exp Orthop ; 11(3): e12051, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38899047

RESUMO

Purpose: The discoid meniscus (DM) is distinguished by its thickened, disc-shaped formation, which extends over the tibial plateau. The likelihood of developing osteoarthritis escalates if a DM tear remains undiagnosed and untreated. While DM tears can be diagnosed through arthroscopy, the high cost, invasive nature and limited availability of this procedure highlight the need for a better diagnostic modality. This study aims to determine the accuracy of magnetic resonance imaging (MRI) in diagnosing DM tears. Methods: A systematic review was conducted to gather articles with at least 10 cases on the comparison of MRI and arthroscopy as the gold standard for DM tear diagnosis. Stata and MetaDisc were used to conduct the statistical analysis. The quality of the included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Results: Five diagnostic performance studies, derived from four original research papers involving 305 patients, were evaluated. Based on the pooled data, the sensitivity, specificity, diagnostic odds ratio, positive limit of detection and negative limit of detection were found to be 0.87 (95% confidence interval [CI], 0.82-0.91) and 0.84 (95% CI, 0.75-0.90), 32.88 (95% CI, 5.81-186.02), 5.22 (95% CI, 1.71-15.92) and 0.18 (95% CI, 0.09-0.38), respectively. A hierarchical summary receiver operating characteristic curve with an area under the curve of 0.92 was generated. Conclusion: This meta-analysis demonstrates that MRI has excellent sensitivity and specificity for diagnosing DM tears. Despite its lower accuracy compared to arthroscopy, MRI can be used in symptomatic patients as a viable alternative to arthroscopy due to its inherent advantages. Level of Evidence: Level IV.

5.
Sci Rep ; 14(1): 14407, 2024 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-38909047

RESUMO

Sarcopenia is linked to chronic inflammation and muscle wasting. This research aims to compare the screening accuracy of tools for sarcopenia in axial spondyloarthritis (axSpA). A cross-sectional study involving 104 axSpA patients was conducted at Phramongkutklao Hospital between January 2020 and February 2021. Sarcopenia was diagnosed according to the AWGS 2019 criteria. Appendicular skeletal muscle mass was measured using DXA. SARC-F, SARC-CalF, and SARC-F+EBM, muscle strength, and physical performance were assessed. The screening tests were evaluated using ROC curves. The optimal cutoffs were identified with the Youden index. Most patients were male (74%), with a mean (SD) age and disease duration of 42.6 (12.22) and 8.3 (8.5), respectively. The prevalence of sarcopenia was 22.1%. The AUCs (95% CI) for calf circumference, SARC-F, SARC-CalF, SARC-F+EBM, handgrip strength, chair stand time, gait speed, and time and go test were 0.830 (0.734, 0.925), 0.509 (0.373-0.645), 0.782 (0.670-0.894), 0.856 (0.758-0.954), 0.710 (0.594-0.825), 0.640 (0.508-0.772), 0.689 (0.539-0.839), and 0.711 (0.576-0.846), respectively. The optimal cutoffs for SARC-F, SARC-CalF, and SARC-F+EBM were 1, 10, and 10, with sensitivity/specificity of 81.0%/29.7%, 90.5%/68.9%, and 77.3%/87.2%, respectively. Calf circumference, SARC-CalF, and SARC-F+EBM had the best performance to screen for sarcopenia in axSpA patients. Lowering the thresholds would potentially enhance the performances of SARC-CalF and SARC-F+EBM.


Assuntos
Espondiloartrite Axial , Sarcopenia , Humanos , Sarcopenia/diagnóstico , Sarcopenia/epidemiologia , Masculino , Feminino , Adulto , Estudos Transversais , Pessoa de Meia-Idade , Espondiloartrite Axial/diagnóstico , Força da Mão , Força Muscular , Músculo Esquelético/patologia , Músculo Esquelético/fisiopatologia , Músculo Esquelético/diagnóstico por imagem , Programas de Rastreamento/métodos , Curva ROC , Prevalência
6.
Pediatr Radiol ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831055

RESUMO

BACKGROUND: Multiple differentials exist for pediatric liver tumors under 2 years. Accurate imaging diagnosis may obviate the need for tissue sampling in most cases. OBJECTIVE: To evaluate the imaging features and diagnostic accuracy of computed tomography (CT) in liver tumors in children under 2 years. METHODS: Eighty-eight children under 2 years with treatment naive liver neoplasms and baseline contrast-enhanced CT were included in this institutional review board approved retrospective study. Two blinded onco-radiologists assessed these tumors in consensus. Findings assessed included enhancement pattern, lobulated appearance, cystic change, calcifications, central scar-like appearance, and metastases. The radiologists classified the lesion as hepatoblastoma, infantile hemangioma, mesenchymal hamartoma, rhabdoid tumor, or indeterminate, first based purely on imaging and then after alpha-fetoprotein (AFP) correlation. Multivariate analysis and methods of comparing means and frequencies were used for statistical analysis wherever applicable. Diagnostic accuracy, sensitivity, and positive predictive values were analyzed. RESULTS: The mean age of the sample was 11.4 months (95% CI, 10.9-11.8) with 50/88 (57%) boys. The study included 72 hepatoblastomas, 6 hemangiomas, 4 mesenchymal hamartomas, and 6 rhabdoid tumors. Presence of calcifications, multilobular pattern of arterial enhancement, lobulated morphology, and central scar-like appearance was significantly associated with hepatoblastomas (P-value < 0.05). Fourteen out of eighty-eight lesions were called indeterminate based on imaging alone; six lesions remained indeterminate after AFP correlation. Pure radiology-based diagnostic accuracy was 81.8% (95% CI, 72.2-89.2%), which increased to 92.1% (95% CI, 84.3-96.7%) (P-value > 0.05) after AFP correlation, with one hepatoblastoma misdiagnosed as a rhabdoid tumor. If indeterminate lesions were excluded for biopsy, the accuracy would be 98.8% (95% CI, 93.4-99.9%). CONCLUSION: CT had high accuracy for diagnosing liver neoplasms in the under 2-year age population after AFP correlation. Certain imaging features were significantly associated with the diagnosis of hepatoblastoma. A policy of biopsying only indeterminate lesions after CT and AFP correlation would avoid sampling in the majority of patients.

7.
Ophthalmol Sci ; 4(5): 100503, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38881612

RESUMO

Purpose: This study aims to explore the potential subgroups of sarcoidosis-associated uveitis (SAU) within a multicenter cohort of uveitis participants. Design: Cross-sectional study. Participants: A cohort of 826 uveitis patients from a uveitis registry from 19 clinical centers in 12 countries between January 2011 and April 2015. Methods: We employed a latent class analysis (LCA) incorporating recommended tests and clinical signs from the revised International Workshop on Ocular Sarcoidosis (IWOS) to identify potential SAU subgroups within the multicenter uveitis cohort. Additionally, we assessed the performance of the individual tests and clinical signs in classifying the potential subclasses. Main Outcome Measures: Latent subtypes of SAU. Results: Among 826 participants included in this analysis, the 2-class LCA model provided a best fit, with the lowest Bayesian information criteria of 7218.7 and an entropy of 0.715. One class, consisting of 548 participants, represented the non-SAU, whereas the second class, comprised of 278 participants, was most representative of SAU. Snowballs/string of pearls vitreous opacities had the best test performance for classification, followed by bilaterality and bilateral hilar lymphadenopathy (BHL). The combination of 4 tests with the highest classification importance, including snowballs/string of pearls vitreous opacities, periphlebitis and/or macroaneurysm, bilaterality, and BHL, demonstrated a sensitivity of 84.8% and a specificity of 95.4% in classifying the SAU subtypes. In the exploratory analysis of the 3-class LCA model, which had comparable fit indices as the 2-class model, we identified a candidate non-SAU subtype, candidate SAU subtype with pulmonary involvement, and a candidate SAU with less pulmonary involvement. Conclusions: Latent class modeling, incorporating tests and clinical signs from the revised IWOS criteria, effectively identified a subset of participants with clinical features indicative of SAU. Though the sensitivity of individual ocular signs or tests was not perfect, using a combination of tests provided a satisfactory performance in classifying the SAU subclasses identified by the 2-class LCA model. Notably, the classes identified by the 3-class LCA model, including a non-SAU subtype, an SAU subtype with pulmonary involvement, and an SAU subtype with less pulmonary involvement, may have potential implication for clinical practice, and hence should be validated in further research. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

8.
EJNMMI Res ; 14(1): 45, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702532

RESUMO

BACKGROUND: Thymic cysts are a rare benign disease that needs to be distinguished from low-risk thymoma. [18F]fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) is a non-invasive imaging technique used in the differential diagnosis of thymic epithelial tumours, but its usefulness for thymic cysts remains unclear. Our study evaluated the utility of visual findings and quantitative parameters of [18F]FDG PET/CT for differentiating between thymic cysts and low-risk thymomas. METHODS: Patients who underwent preoperative [18F]FDG PET/CT followed by thymectomy for a thymic mass were retrospectively analyzed. The visual [18F]FDG PET/CT findings evaluated were PET visual grade, PET central metabolic defect, and CT shape. The quantitative [18F]FDG PET/CT parameters evaluated were PET maximum standardized uptake value (SUVmax), CT diameter (cm), and CT attenuation in Hounsfield units (HU). Findings and parameters for differentiating thymic cysts from low-risk thymomas were assessed using Pearson's chi-square test, the Mann-Whitney U-test, and receiver operating characteristics (ROC) curve analysis. RESULTS: Seventy patients (18 thymic cysts and 52 low-risk thymomas) were finally included. Visual findings of PET visual grade (P < 0.001) and PET central metabolic defect (P < 0.001) showed significant differences between thymic cysts and low-risk thymomas, but CT shape did not. Among the quantitative parameters, PET SUVmax (P < 0.001), CT diameter (P < 0.001), and CT HU (P = 0.004) showed significant differences. In ROC analysis, PET SUVmax demonstrated the highest area under the curve (AUC) of 0.996 (P < 0.001), with a cut-off of equal to or less than 2.1 having a sensitivity of 100.0% and specificity of 94.2%. The AUC of PET SUVmax was significantly larger than that of CT diameter (P = 0.009) and CT HU (P = 0.004). CONCLUSIONS: Among the [18F]FDG PET/CT parameters examined, low FDG uptake (SUVmax ≤ 2.1, equal to or less than the mediastinum) is a strong diagnostic marker for a thymic cyst. PET visual grade and central metabolic defect are easily accessible findings.

9.
AJOG Glob Rep ; 4(2): 100346, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38694483

RESUMO

BACKGROUND: The current version of the Fetal Medicine Foundation competing risks model for preeclampsia prediction has not been previously validated in Brazil. OBJECTIVE: This study aimed (1) to validate the Fetal Medicine Foundation combined algorithm for the prediction of preterm preeclampsia in the Brazilian population and (2) to describe the accuracy and calibration of the Fetal Medicine Foundation algorithm when considering the prophylactic use of aspirin by clinical criteria. STUDY DESIGN: This was a cohort study, including consecutive singleton pregnancies undergoing preeclampsia screening at 11 to 14 weeks of gestation, examining maternal characteristics, medical history, and biophysical markers between October 2010 and December 2018 in a university hospital in Brazil. Risks were calculated using the 2018 version of the algorithm available on the Fetal Medicine Foundation website, and cases were classified as low or high risk using a cutoff of 1/100 to evaluate predictive performance. Expected and observed cases with preeclampsia according to the Fetal Medicine Foundation-estimated risk range (≥1 in 10; 1 in 11 to 1 in 50; 1 in 51 to 1 in 100; 1 in 101 to 1 in 150; and <1 in 150) were compared. After identifying high-risk pregnant women who used aspirin, the treatment effect of 62% reduction in preterm preeclampsia identified in the Combined Multimarker Screening and Randomized Patient Treatment with Aspirin for Evidence-Based Preeclampsia Prevention trial was used to evaluate the predictive performance adjusted for the effect of aspirin. The number of potentially unpreventable cases in the group without aspirin use was estimated. RESULTS: Among 2749 pregnancies, preterm preeclampsia occurred in 84 (3.1%). With a risk cutoff of 1/100, the screen-positive rate was 25.8%. The detection rate was 71.4%, with a false positive rate of 24.4%. The area under the curve was 0.818 (95% confidence interval, 0.773-0.863). In the risk range ≥1/10, there is an agreement between the number of expected cases and the number of observed cases, and in the other ranges, the predicted risk was lower than the observed rates. Accounting for the effect of aspirin resulted in an increase in detection rate and positive predictive values and a slight decrease in the false positive rate. With 27 cases of preterm preeclampsia in the high-risk group without aspirin use, we estimated that 16 of these cases of preterm preeclampsia would have been avoided if this group had received prophylaxis. CONCLUSION: In a high-prevalence setting, the Fetal Medicine Foundation algorithm can identify women who are more likely to develop preterm preeclampsia. Not accounting for the effect of aspirin underestimates the screening performance.

10.
Oral Oncol ; 153: 106823, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38701572

RESUMO

Resection margins of oral squamous cell carcinoma (SCC) are often inadequate. A systematic review on clinical intraoperative whole-specimen imaging techniques to obtain adequate deep resection margins in oral SCC is lacking. Such a review may render better alternatives for the current insufficient intraoperative techniques: palpation and frozen section analyses (FSA). This review resulted in ten publications investigating ultrasound (US), four investigating fluorescence, and three investigating MRI. Both US and fluorescence were able to image the tumor intraorally and perform ex-vivo imaging of the resection specimen. Fluorescence was also able to image residual tumor tissue in the wound bed. MRI could only be used on the ex-vivo specimen. The 95 % confidence intervals for sensitivity and specificity were large, due to the small sample sizes for all three techniques. The sensitivity and specificity of US for identifying < 5 mm margins ranged from 0 % to 100 % and 60 % to 100 %, respectively. For fluorescence, this ranged from 0 % to 100 % and 76 % to 100 %, respectively. For MRI, this ranged from 7 % to 100 % and 81 % to 100 %, respectively. US, MRI and fluorescence are the currently available imaging techniques that can potentially be used intraoperatively and which can image the entire tumor-free margin, although they have insufficient sensitivity for identifying < 5 mm margins. Further research on larger cohorts is needed to improve the sensitivity by determining cut-off points on imaging for inadequate margins. This improves the number of adequate resections of oral SCC's and pave the way for routine clinical implementation of these techniques.


Assuntos
Carcinoma de Células Escamosas , Margens de Excisão , Neoplasias Bucais , Humanos , Neoplasias Bucais/diagnóstico por imagem , Neoplasias Bucais/cirurgia , Neoplasias Bucais/patologia , Carcinoma de Células Escamosas/cirurgia , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Sensibilidade e Especificidade
11.
Clin Nutr ESPEN ; 61: 46-51, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38777472

RESUMO

BACKGROUND & AIMS: Tools for screening of nutrition risk in patients with cancer are usually validated against other screening instruments. Here with the performance of Malnutrition Screening Tool (MST) and Nutritional Screening Tool (NUTRISCORE) to identify the risk of malnutrition was assessed. A full nutritional evaluation and diagnosis following criteria from the Global Leadership Initiative of Malnutrition (GLIM) was the reference standard for the classification of malnutrition. METHODS: Diagnostic test prospective analysis of adult patients with a confirmed diagnosis of cancer. MST, NUTRISCORE and nutritional evaluation and diagnosis by GLIM criteria were independently performed within 24 h of admission to a 4th tier hospital in Bogotá, Colombia. RESULTS: From 439 patients the sensitivity and specificity of MST was 75% and 94% and of NUTRISCORE 45% and 97% respectively. The area under receiver operating characteristic (ROC) curves were 0.90 for MST and 0.85 for NUTRISCORE (p = 0.003). CONCLUSION: The MST showed a significantly better diagnostic performance over NUTRISCORE for detection of malnutrition risk at admission to hospital of patients with cancer.


Assuntos
Desnutrição , Neoplasias , Avaliação Nutricional , Estado Nutricional , Humanos , Desnutrição/diagnóstico , Neoplasias/complicações , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Adulto , Curva ROC , Programas de Rastreamento/métodos , Colômbia , Sensibilidade e Especificidade , Hospitalização , Fatores de Risco , Medição de Risco
12.
RMD Open ; 10(2)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38749532

RESUMO

OBJECTIVES: To investigate lectin pathway proteins (LPPs) as biomarkers for axial spondyloarthritis (axSpA) in a cross-sectional cohort with a suspicion of axSpA, comprising newly diagnosed axSpA and chronic low back pain (cLBP) individuals. METHODS: Serum samples from 515 participants within the OptiRef cohort, including 151 axSpA patients and 364 cLBP patients, were measured using immunoassays for LPPs (mannan-binding lectin (MBL), collectin liver-1 (CL-L1), M-ficolin, H-ficolin and L-ficolin, MBL-associated serine proteases (MASP)-1, -2 and -3, MBL-associated proteins (MAp19 and MAp44) and the complement activation product C3dg). RESULTS: Serum levels of L-ficolin, MASP-2 and C3dg were elevated in axSpA patients, whereas levels of MASP-3 and CL-L1 were decreased, and this remained significant for C3dg and MASP-3 after adjustment for C reactive protein (CRP). A univariate regression analysis showed serum levels of CL-L1, MASP-2, MASP-3 and C3dg to predict the diagnosis of axSpA, and MASP-3 and C3dg remained significant in a multivariate logistic regression analysis. Assessment of the diagnostic potential showed that a combination of human leukocyte antigen B27 (HLA-B27) and measurements of L-ficolin, MASP-3 and C3dg increased the diagnostic specificity for axSpA, however, with a concomitant loss of sensitivity. CONCLUSIONS: Serum levels of complement activation, that is, C3dg, and MASP-3 differed significantly between axSpA and cLBP patients after adjustment for CRP. Although combining HLA-B27 with measurements of L-ficolin, MASP-3 and C3dg increased the diagnostic specificity for axSpA, this seems unjustified due to the concomitant loss of sensitivity. However, both C3dg and MASP-3 were associated with axSpA diagnosis in multivariate logistic regression, suggesting an involvement of complement in the inflammatory processes and possibly pathogenesis in axSpA.


Assuntos
Espondiloartrite Axial , Biomarcadores , Proteínas do Sistema Complemento , Humanos , Biomarcadores/sangue , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Estudos Transversais , Proteínas do Sistema Complemento/metabolismo , Proteínas do Sistema Complemento/análise , Espondiloartrite Axial/diagnóstico , Espondiloartrite Axial/sangue , Espondiloartrite Axial/etiologia , Serina Proteases Associadas a Proteína de Ligação a Manose/metabolismo , Serina Proteases Associadas a Proteína de Ligação a Manose/análise , Lectinas/sangue , Ativação do Complemento
13.
Res Dev Disabil ; 150: 104748, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38744072

RESUMO

BACKGROUND: The Developmental Coordination Disorder Questionnaire (DCDQ) has been used to screen children who probably have developmental coordination disorder (DCD). AIMS: We systematically reviewed studies on the predictive validity of the DCDQ and performed a meta-analysis on its diagnostic accuracy. METHODS AND PROCEDURES: Literature was searched through four electronic databases: MEDLINE, Embase, CINAHL, and PsycArticles. A total of 27 studies was selected based on the inclusion criteria. The sensitivity and specificity of the DCDQ were assessed using summary receiver operating characteristic (sROC) curves. Subgroup analyses were conducted according to the DCDQ type, reference standard, and participant type. OUTCOMES AND RESULTS: Overall, the DCDQ has a sensitivity of 0.70 and a specificity of 0.77, showing moderate diagnostic accuracy (area under the curve, 0.80). Subgroup analysis showed that the revised version of the DCDQ had higher diagnostic accuracy than the original version. When the reference standard was the Diagnostic and Statistical Manual of Mental Disorders, the sensitivity and specificity of the DCDQ were 0.87 and 0.83, respectively. The diagnostic accuracy was higher in clinical samples compared to the general population. CONCLUSIONS AND IMPLICATIONS: This study demonstrated that the DCDQ has adequate diagnostic accuracy, suggesting it can help screen children with motor skill deficits.


Assuntos
Transtornos das Habilidades Motoras , Sensibilidade e Especificidade , Criança , Humanos , Programas de Rastreamento/métodos , Transtornos das Habilidades Motoras/diagnóstico , Reprodutibilidade dos Testes , Curva ROC , Inquéritos e Questionários/normas
14.
Asian J Neurosurg ; 19(1): 1-7, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38751395

RESUMO

Objectives The Glasgow Coma Scale (GCS) is widely used and considered the gold standard in assessing the consciousness of patients with traumatic brain injury. However, some significant limitations, like the considerable variations in interobserver reliability and predictive validity, were the reason for developing the Full Outline of Unresponsiveness (FOUR) score. The current study aims to compare the prognostic accuracy of the FOUR score with the GCS score for in-hospital mortality and morbidity among patients with traumatic brain injury. Materials and Methods A prospective cohort study was conducted, where 237 participants were selected by consecutive sampling from a tertiary care center. These patients were assessed with the help of GCS and FOUR scores within 6 hours of admission, and other clinical parameters were also noted. The level of consciousness was checked every day with the help of GCS and FOUR scores until their last hospitalization day. Glasgow Outcome Scale was used to assess their outcome on the last day of hospitalization. The GCS and FOUR scores were compared, and data were analyzed by descriptive and inferential statistics. The chi-square test, independent Student's t -test, and receiver operating characteristic analysis were used for inferential analysis. Results The area under the curve (AUC) for the GCS score at the 6th hour for predicting mortality was 0.865 with a cutoff value of 5.5, and it yields a sensitivity of 87% and a specificity of 64%. The AUC for FOUR scores at the 6th hour for predicting the mortality was 0.893, with a cutoff value of 5.5, and it yields a sensitivity of 87% and a specificity of 73%. Conclusion The current study shows that, as per the AUC of GCS and FOUR scores, their sensitivity was equal, but specificity was higher in the FOUR score. So, the FOUR score has higher accuracy than the GCS score in the prediction of mortality among traumatic brain injury patients.

15.
Cureus ; 16(4): e58018, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38738151

RESUMO

Objective Among the common causes of abdominal emergencies, acute appendicitis ranks at the top, particularly in the young population. While negative appendectomy is not uncommon, the risk of appendicular perforation is substantial if the diagnosis is missed or delayed. This study evaluated the diagnostic efficacy of the Tzanakis scoring system for acute appendicitis, comparing it with the Alvarado scoring system, considering the histopathological finding as the gold standard. Materials and methods This prospective observational study, conducted in the General Surgery department in a tertiary care hospital in India, included clinically diagnosed acute appendicitis cases posted for open or laparoscopic appendicectomy. Results The mean age for the 60 participants included in the study was 30.97±13.44, and the median was 24.5 yrs. The sensitivity of ultrasonography (USG) in diagnosing histopathological positive acute appendicitis was 89%, and the specificity was 50%. The sensitivity, specificity, positive, and negative predictive values of the Tzanakis score were 87%, 50%, 96%, and 22%, respectively, and those of the Alvarado score were 54%, 75%, 96%, and 10%, respectively. Conclusion The receiver operator characteristic (ROC) curve for the Alvarado and Tzanakis scores showed that the area under the curve (AUC) was greater for the Tzanakis scoring system (0.670) than for the Alvarado scoring system (0.598). Differences between the AUCs were not statistically significant. Although the Tzanakis scoring system is more sensitive than the Alvarado scoring system in diagnosing acute appendicitis, studies with larger samples are needed to show the superiority of this scoring system over the Alvarado scoring system.

16.
Sci Rep ; 14(1): 9965, 2024 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-38693152

RESUMO

To quantitatively assess the diagnostic efficacy of multiple parameters derived from multi-b-value diffusion-weighted imaging (DWI) using turbo spin echo (TSE)-based acquisition techniques in patients with solitary pulmonary lesions (SPLs). A total of 105 patients with SPLs underwent lung DWI using single-shot TSE-based acquisition techniques and multiple b values. The apparent diffusion coefficient (ADC), intravoxel incoherent motion (IVIM) parameters, and lesion-to-spinal cord signal intensity ratio (LSR), were analyzed to compare the benign and malignant groups using the Mann-Whitney U test and receiver operating characteristic analysis. The Dstar values observed in lung cancer were slightly lower than those observed in pulmonary benign lesions (28.164 ± 31.950 versus 32.917 ± 34.184; Z = -2.239, p = 0.025). The LSR values were significantly higher in lung cancer than in benign lesions (1.137 ± 0.581 versus 0.614 ± 0.442; Z = - 4.522, p < 0.001). Additionally, the ADC800, ADCtotal, and D values were all significantly lower in lung cancer than in the benign lesions (Z = - 5.054, -5.370, and -6.047, respectively, all p < 0.001), whereas the f values did not exhibit any statistically significant difference between the two groups. D had the highest area under the curve (AUC = 0.887), followed by ADCtotal (AUC = 0.844), ADC800 (AUC = 0.824), and LSR (AUC = 0.789). The LSR, ADC800, ADCtotal, and D values did not differ statistically significantly in diagnostic effectiveness. Lung DWI using TSE is feasible for differentiating SPLs. The LSR method, conventional DWI, and IVIM have comparable diagnostic efficacy for assessing SPLs.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias Pulmonares , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Diagnóstico Diferencial , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Idoso , Adulto , Curva ROC , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/patologia , Nódulo Pulmonar Solitário/diagnóstico , Idoso de 80 Anos ou mais , Pulmão/diagnóstico por imagem , Pulmão/patologia
17.
RMD Open ; 10(2)2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38772677

RESUMO

OBJECTIVES: Non-adherence to rheumatoid arthritis (RA) treatments must be identified. A methotrexate (MTX) urinary dosage (METU) was recently developed. The aim of our study was to assess adherence to MTX in RA using METU in real-life conditions and to compare it with indirect adherence measurement technics. METHODS: We performed a cross-sectional study at Reims University Hospital. We included over 18-year-old patients with RA treated by MTX for more than 6 months. Patients were invited to complete demographic, clinical and psychological questionnaires and adherence measurement technics (Compliance Questionnaire of Rheumatology (CQR) and Medication Possession Ratio (MPR)). A urinary sample was collected to measure MTX and information about tolerance was evaluated through Methotrexate Intolerance Severity Score. RESULTS: 84 patients were included, 26 using oral MTX, 58 subcutaneous (SC) MTX. Among them, 73% were female, mean age was 61.5 years, MTX mean dose was 15 mg/week and 61.9% were treated by biological DMARDs (Disease Modifying Antirheumatic Drugs). 77 patients (91.7%) were adherent to treatment according to METU, whereas MPR and CQR reported less adherence (69.5% and 61.9%, respectively). MPR and METU were not significantly different in SC MTX users (p=0.059). Non-adherent patients had a higher number of tender joints and C reactive protein value (p<0.05). CONCLUSION: This is the first largest study evaluating MTX adherence in patients with RA using a urinary dosage. We identified that indirect adherence measurements did not reflect real-life adherence. It would be appreciable to realise METU, in a new study, in patients with RA with unexplained response to treatment, to consider it before escalating therapeutic strategy.


Assuntos
Antirreumáticos , Artrite Reumatoide , Adesão à Medicação , Metotrexato , Humanos , Artrite Reumatoide/tratamento farmacológico , Artrite Reumatoide/urina , Metotrexato/administração & dosagem , Metotrexato/uso terapêutico , Metotrexato/efeitos adversos , Feminino , Masculino , Antirreumáticos/uso terapêutico , Antirreumáticos/administração & dosagem , Estudos Transversais , Pessoa de Meia-Idade , Idoso , Inquéritos e Questionários , Adulto , Biomarcadores/urina
18.
Phys Ther ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38590288

RESUMO

OBJECTIVE: This study compared adults with peripheral vestibular hypofunction (VH) to healthy controls and assessed the sensitivity and specificity of the Cervical Torsion Test (CTT) and the Head Neck Differentiation Test (HNDT). This study aimed to determine whether neck problems affected primary outcomes. METHODS: This cross-sectional study included adults from a specialist consultation for dizziness. VH had been diagnosed with the video Head Impulse Test. Exclusion criteria were conditions following head or neck trauma and diseases of the central nervous system. Sensitivity and specificity of the index tests were calculated, and regression analyses were performed to test for contributing factors. RESULTS: A total of 19 patients with VH and a historical cohort of 19 matched healthy controls were included. Most patients with VH (84.2%) experienced symptoms in at least 1 test component, compared to 5.2% of the control group. Of patients with VH, 78.9% had symptoms during the HNDT "en bloc" (en bloc = head and trunk rotated together) whereas only 26.3% reported symptoms during the CTT en bloc. Best discriminatory validity was found for the HNDT en bloc, with a sensitivity of 0.79 (95% CI = 0.54-0.94), a specificity of 0.86 (95% CI = 0.65-0.97), and a positive likelihood ratio of 5.79 (95% CI = 1.97-17.00). The number of symptoms of CTT "in torsion" (in torsion = trunk rotated actively with fixed head) was increased by a factor of 1.13 (95% CI = 1.01-1.27) for every additional point on the Neck Disability Index. CONCLUSIONS: The CTT and HNDT can serve as nonlaboratory tests in patients with dizziness. The HNDT en bloc has the best discriminatory validity, finding those with and those without VH. Symptom reproduction during torsion may help to identify when neck problems may contribute to dizziness. IMPACT: The HNDT en bloc may be useful for ruling VH in or out in patients with dizziness. Positive CTT and HNDT in torsion components may verify the likelihood of additional neck involvement.

19.
Clin Epidemiol ; 16: 249-256, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38623485

RESUMO

Purpose: Hypertension is an important risk factor in cardio-epidemiological research, but data quality remains a concern. We validated different registry-based definitions of hypertension. Patients and Methods: The cohort included all first-time responders of the Danish National Health Surveys (2010, 2013, or 2017). Prescription-defined hypertension was defined as ≥1 or ≥2 filled prescriptions of antihypertensive specific drugs in ≥1 or ≥2 different antihypertensive drug classes within 90, 180, or 365 days before survey response. Hospital-diagnosed hypertension was defined from hypertension diagnoses within five years before the survey response. Considering self-reported hypertension as the reference, we calculated the positive predictive value (PPV), the negative predictive value (NVP), the sensitivity, and the specificity of prescription-defined and hospital-diagnosed hypertension. Results: Among 442,490 survey responders, 127,247 (29%) had self-reported hypertension. For prescription-defined hypertension with 365-day lookback, the PPV was highest for ≥2 prescriptions in ≥2 drug classes (94%) and lowest for ≥1 prescription in ≥1 drug class (85%). The NPV was highest for ≥1 prescription in ≥2 drug classes (94%) and lowest for ≥1 prescription in ≥2 drug classes (80%). The sensitivity was highest for ≥1 prescription in ≥1 drug class (79%) and lowest for ≥2 prescriptions in ≥2 drug classes (30%). The specificity was ≥94% for all algorithms. The PPV and specificity did not change noteworthy with length of lookback period, whereas the NPV and the sensitivity generally were higher for longer lookback. The algorithm ≥1 prescription in ≥2 drug classes with 365-day lookback was among the best balanced across all measures of validity (PPV=88%, NPV=94%, sensitivity=75%, specificity=96%). For hospital-diagnosed hypertension, the PPV was 90%, the NPV was 76%, the sensitivity was 22%, and the specificity was 99%. Conclusion: Compared with self-reported hypertension, the algorithms for prescription-defined and hospital-diagnosed hypertension had high predictive values and specificity, but low sensitivity.

20.
Children (Basel) ; 11(4)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38671704

RESUMO

Diagnosis of neonatal sepsis is difficult due to nonspecific signs and symptoms. Interleukin-6 (IL-6) is a promising marker for neonatal sepsis. We aimed to test the accuracy of IL-6 in neonates after 72 h of life in case of late onset sepsis (LOS). We searched for studies regarding IL-6 accuracy for the diagnosis of LOS between 1990 and 2020 using the PubMed database. Following study selection, the reported IL-6 sensitivities and specificities ranged between 68% and 100% and 28% and 100%, with median values of 85.7% and 82% and pooled values of 88% and 78% (respectively) in the 15 studies including 1306 infants. Subgroup analysis revealed a better sensitivity (87% vs. 82%), but not specificity (both 86%), in preterm infants compared to term infants or mixed populations. Early sample collection revealed the highest sensitivity (84%), but had the lowest specificity (86%). To assess quality, we used a STARD checklist adapted for septic neonates and the QUADAS criteria. Limitations of this review include the heterogeneous group of studies on the one side and the small number of studies on the other side that analyzed different combinations of biomarkers. We concluded that IL-6 demonstrated good performance especially in the preterm infant population and the best results were achieved by measurements at the time of LOS suspicion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...