Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 548
Filtrar
1.
Rev Esp Geriatr Gerontol ; 60(1): 101557, 2024 Oct 04.
Artigo em Espanhol | MEDLINE | ID: mdl-39368252

RESUMO

BACKGROUND AND OBJECTIVE: Frailty in older adults is a geriatric syndrome that has gained importance in the last decade. However, there is still no consolidated information regarding diagnostic tools that allow timely identification, and therefore, provide an appropriate therapeutic approach. The objective is to determine the Thickness of the Rectus Femoris Muscle (GMRF) and Thickness of the Vastus Intermedius Muscle (GMVI) in older Mexican adults with frailty and sarcopenia. MATERIAL AND METHODS: Cross-sectional, descriptive and comparative study in patients ≥65 years of age, admitted to the geriatrics service. The selection was according to the FRAIL (frail vs. non-frail) and SARC-F (high risk vs. low risk) classification; evaluating GMRF and GMVI by ultrasound. The data were analyzed through the statistical software Statistical Package for Social Sciences (SPSS) ver. 25. RESULTS: The number of patients evaluated in the study and control group were 136 respectively. Significant differences were found regarding frailty status in age (years) (Frail: 75.06±7.92 vs. Non-frail: 71.60±5.56; P<.001), GMRF (mm) (Frail: 8.41±3.08 vs. Non-frail: 11.03±3.50; P<.001) and GMVI (mm) (Frail: 6.53±2.64 vs. Non-frail: 8.66±2.68; P<.001); Considering sarcopenia, there were differences in age (years) (High risk sarcopenia: 75.17±7.84: vs low risk sarcopenia; 71.49±5.60; P<.001), GMRF (mm) (high risk sarcopenia: 8.45±3.11 vs low risk sarcopenia: 10.98±3.50; P<.001) and GMVI (mm) (High risk Sarcopenia: 6.67±2.63 vs Low risk Sarcopenia: 8.52±2.79; P<.001). CONCLUSIONS: The results found show that there is a significant difference in GMRF and GMVI in Mexican older adults with respect to frailty and sarcopenia. In this way, the present investigation establishes clinical bases for the use of ultrasonography assessments in the geriatric population.

2.
Rev. obstet. ginecol. Venezuela ; 84(3): 235-249, Ago. 2024. tab
Artigo em Espanhol | LILACS, LIVECS | ID: biblio-1570278

RESUMO

Objetivo: Identificar y clasificar las diferentes anomalías del desarrollo diagnosticadas en la unidad de ecografía del servicio de medicina materno fetal de la Maternidad Concepción Palacios entre enero y diciembre de 2023. Métodos: Estudio retrospectivo, descriptivo, transversal que incluyó la evaluación de los 4225 reportes de ultrasonido obstétrico realizados en 2023. Se excluyeron los estudios sin diagnóstico morfológico. Las variables evaluadas fueron características clínicas de las gestantes, prevalencia según tipo de anomalía del desarrollo y según el aparato o sistema afectado. Resultados: Se diagnosticaron anomalías del desarrollo en 282 pacientes, para una frecuencia de 6,7 %. Las anomalías fueron únicas en 187 casos (66,3 %) y múltiples en 95 pacientes (33,7 %). El total de malformaciones fue 360 (8,5 %). El mínimo de lesiones detectadas fue una y el máximo fue tres. El sistema afectado con mayor frecuencia fue el sistema nervioso central, con 104 casos (28,9 %); le siguen, en orden de frecuencia, los marcadores aislados, vistos en 92 pacientes (25,6 %) y las anomalías cardiovasculares, en 49 fetos (13,6 %). Conclusión: La frecuencia de malformaciones congénitas diagnosticadas en el año 2023 fue de 6,7 % de las ecografías realizadas en la unidad de ecografía del servicio de medicina materno fetal de la Maternidad Concepción Palacios; en las dos terceras partes de los casos fueron únicas y el tercio restante fueron múltiples. En orden de frecuencia, los sistemas afectados fueron sistema nervioso central, marcadores aislados de aneuploidías y anomalías cardiovasculares(AU)


Objective: To identify and classify the different developmental anomalies diagnosed in the ultrasound unit of the maternal-fetal medicine service of the Concepción Palacios Maternity Hospital between January and December 2023. Methods: Retrospective, descriptive, cross-sectional study that included the evaluation of the 4225 obstetric ultrasound reports performed in 2023. Studies without morphological diagnosis were excluded. The variables evaluated were clinical characteristics of the pregnant women, prevalence according to type of developmental anomaly and according to the affected apparatus or system. Results: Developmental abnormalities were diagnosed in 282 patients, with a frequency of 6.7%. The anomalies were single in 187 cases (66.3%) and multiple in 95 patients (33.7%). The total number of malformations was 360 (8.5%). The minimum number of injuries detected was one and the maximum was three. The most frequently affected system was the central nervous system, with 104 cases (28.9%); This is followed by isolated markers, seen in 92 patients (25.6%), and cardiovascular anomalies, in 49 fetuses (13.6%). Conclusion: The frequency of congenital malformations diagnosed in 2023 was 6.7% of the ultrasound scans performed in the ultrasound unit of the maternal-fetal medicine service of the Concepción Palacios Maternity Hospital; Two-thirds of the cases were singles and the remaining third were multiples. In order of frequency, the affected systems were central nervous system, isolated markers of aneuploidies, and cardiac anomalies(AU)


Assuntos
Humanos , Feminino , Gravidez , Adolescente , Adulto , Pessoa de Meia-Idade , Perinatologia , Diagnóstico Pré-Natal , Anormalidades Congênitas , Poder Familiar , Ultrassom , Sistema Nervoso Central , Ultrassonografia , Gestantes , Feto , Maternidades
3.
Artigo em Inglês | MEDLINE | ID: mdl-38701893

RESUMO

INTRODUCTION AND OBJECTIVES: Embolic phenomena frequently occur during hip joint replacement surgery, and may lead to haemodynamic instability in frail patients. Transoesophageal ultrasound monitoring is rarely available in non-cardiac operating theatres, and cannot be performed in awake patients under spinal anaesthesia. The main objectives of this prospective exploratory study were to determine the feasibility of using an alternative ultrasound approach to monitor the inferior vena cava during hip replacement surgery, and to determine the intra and interobserver reliability of the ultrasound findings. METHOD: We conducted a prospective exploratory study in 20 patients undergoing cemented hip arthroplasty in the supine position under spinal anaesthesia and sedation. The inferior vena cava was assessed through a subcostal window at 10 intraoperative time points, and the findings were rated on a qualitative embolism severity scale. The ultrasound images were evaluated by 2 independent observers. RESULTS: An adequate subcostal window was obtained in 90% of cases. Intra- and inter-observer reliability was high (kappa index >0.80, p < 0.001). Nearly all (95%) patients presented some degree of embolism, which was severe in 50% of cases. CONCLUSIONS: Our study suggests that ultrasound assessment of embolic phenomena in the inferior vena cava through a subcostal window is feasible in 90% of cases. The qualitative embolic severity rating scale is highly reproducible and has high intra- and inter-observer reliability.


Assuntos
Artroplastia de Quadril , Estudos de Viabilidade , Complicações Intraoperatórias , Veia Cava Inferior , Humanos , Veia Cava Inferior/diagnóstico por imagem , Estudos Prospectivos , Feminino , Masculino , Idoso , Complicações Intraoperatórias/diagnóstico por imagem , Complicações Intraoperatórias/etiologia , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Idoso de 80 Anos ou mais , Ultrassonografia/métodos , Embolia/diagnóstico por imagem , Embolia/etiologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Raquianestesia/métodos
4.
J. oral res. (Impresa) ; 13(1): 47-58, mayo 29, 2024. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1563181

RESUMO

Introduction: Periodontal inflammation causes dysbiosis and change in the microbiota. Nonsurgical periodontal therapy (NSPT) helps in removal of plaque and restoring periodontal health. Various adjunctive therapy like use of mouthwash helps in maintenance of periodontal health and reducing inflammatory load. Materials and Methods: A total of 108 subjects diagnosed with type 2 diabetes mellitus and periodontitis were divided into three groups: Group 1 received NSPT and rinsing with 0.2% chlorhexidine mouthwash for 3 months, Group 2 received NSPT and rinsing with 1.5% hydrogen peroxide mouthwash for 3 months, Group 3- received NSPT only (control group). The clinical parameters measured included Plaque Index (PI), Gingival Index (GI), Bleeding on probing (BOP) and probing (PD) at baseline, 1, 2, 3 months follow up. Salivary interleukin 1ßlevels were measured at baseline and 3 months interval. Results: Group 1, 2 and 3 showed significant reduction in PI, GI, BOP and PD at 1 and 3 months follow up (p<0.05). However, Intergroup comparison of clinical parameters showed significant reduction in group 1 and 2 when compared with group 3 (p<0.05). Salivary interleukin 1-ß levels showed significant reduction from baseline to 3 months in all the three groups and intergroup comparison didn't show any significant changes, (p>0.05). Conclusions: Hydrogen peroxide mouthwash as an adjunct to NSPT can be considered as a safe and effective measure to reduce periodontal inflammation in type 2 diabetes mellitus patients with chronic periodontitis.


Introducción: La inflamación periodontal causa disbiosis y cambios en la microbiota. La terapia periodontal no quirúrgica (NSPT) ayuda a eliminar la placa y restaurar la salud periodontal. Diversas terapias complementarias, como el uso de enjuague bucal, ayudan a mantener la salud periodontal y reducir la carga inflamatoria. Materiales y Métodos: Un total de 108 sujetos diagnosticados con diabetes mellitus tipo 2 y periodontitis se dividieron en tres grupos: el grupo 1 recibió NSPT y enjuague con enjuague bucal de clorhexidina al 0,2% durante 3 meses, el grupo 2 recibió NSPT y enjuague con enjuague bucal de peróxido de hidrógeno al 1,5% durante 3 meses, y el Grupo 3 recibió NSPT únicamente (grupo de control). Los parámetros clínicos medidos fueron el índice de placa (PI), el índice gingival (GI), el sangrado al sondaje (BOP) y al sondaje (PD) al inicio del estudio, 1, 2, y 3 meses de seguimiento. Los niveles de interleucina 1ß en saliva se midieron al inicio y a los 3 meses. Resultado: Los grupos 1, 2 y 3 mostraron una reducción significativa en IP, GI, BOP y PD al mes y 3 meses de seguimiento (p<0,05). Sin embargo, la comparación intergrupal de los parámetros clínicos mostró una reducción significativa en los grupos 1 y 2 en comparación con grupo 3 (p<0,05). Los niveles de interleucina 1-ß salival mostraron una reducción significativa desde el inicio hasta los 3 meses en los tres grupos y la comparación entre grupos no mostró ningún cambio significativo (p>0,05). Conclusión: El enjuague bucal con peróxido de hidrógeno como complemento de la NSPT puede considerarse una medida segura y eficaz para reducir la inflamación periodontal en pacientes con diabetes mellitus tipo 2 y periodontitis crónica.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Clorexidina/uso terapêutico , Periodontite Crônica/terapia , Peróxido de Hidrogênio/uso terapêutico , Antissépticos Bucais/uso terapêutico , Saúde Bucal
5.
Int. j. morphol ; 42(2): 368-373, abr. 2024. ilus
Artigo em Inglês | LILACS | ID: biblio-1558147

RESUMO

SUMMARY: The aim of this study was to compare the clinical value of vertebral artery ultrasound (VAU), Magnetic Resonance Angiography (MRA) and Digital Subtraction Angiography (DSA) on vertebral artery stenosis in patients with posterior circulation ischemia. Seventy-three patients with posterior circulation ischemia underwent vertebral artery ultrasound and magnetic resonance angiography as well as digital subtraction angiography, and the diagnosis of vertebral artery stenosis (VAS) and the degree of stenosis (normal, mild stenosis, moderate stenosis, severe stenosis, and occlusion) were recorded and compared between digital subtraction angiogram and vertebral artery ultrasound and magnetic resonance angiography. The vertebral artery stenosis rates on digital subtraction angiography and vertebral artery ultrasound were 87.30 % (55/63) and 49.20 % (31/63), respectively, and the difference was statistically significant. The rates of vertebral artery stenosis on digital subtraction angiography and, magnetic resonance angiography was 90.38 % (47/52) and 88.46 % (46/ 52), respectively, and the differences was not statistically significant. The sensitivity, accuracy, negative predictive value, and positive predictive value of vertebral artery ultrasound in diagnosing vertebral artery stenosis were 51.35 %, 54.76 %, 18.18 %, and 95.00 %, respectively, lower than those of magnetic resonance angiography, which were 91.89 %, 90.48 %, 57.14 %, and 97.14 %, respectively. Of the noninvasive imaging techniques, vertebral artery ultrasound does not accurately characterize vertebral artery stenosis and its degree of stenosis. Magnetic resonance angiography effectively screens for vertebral artery stenosis and its degree of stenosis, and can be used as a reliable tool for vertebral artery stenosis in posterior circulation cerebral infarction, and can be used in conjunction with digital subtraction angiogram in order to improve diagnostic convenience and accuracy.


El objetivo de este estudio fue comparar el valor clínico de la ecografía de la arteria vertebral (VAU), la angiografía por resonancia magnética (ARM) y la angiografía por sustracción digital (DSA) en la estenosis de la arteria vertebral en pacientes con isquemia de la circulación posterior. A 73 pacientes con isquemia de la circulación posterior se les realizó una ecografía de la arteria vertebral y una angiografía por resonancia magnética, así como una angiografía por sustracción digital, y se les diagnosticó estenosis de la arteria vertebral (EVA) y el grado de estenosis (normal, estenosis leve, estenosis moderada, estenosis grave, y oclusión) se registraron y compararon la angiografía por sustracción digital y la ecografía de la arteria vertebral y la angiografía por resonancia magnética. Las tasas de estenosis de la arteria vertebral en la angiografía por sustracción digital y la ecografía de la arteria vertebral fueron del 87,30 % (55/63) y del 49,20 % (31/63), respectivamente, y la diferencia fue estadísticamente significativa. Las tasas de estenosis de la arteria vertebral en la angiografía por sustracción digital y la angiografía por resonancia magnética fueron del 90,38 % (47/52) y del 88,46 % (46/52), respectivamente, y las diferencias no fueron estadísticamente significativas. La sensibilidad, precisión, valor predictivo negativo y valor predictivo positivo de la ecografía de la arteria vertebral en el diagnóstico de estenosis de la arteria vertebral fueron 51,35 %, 54,76 %, 18,18 % y 95,00 %, respectivamente, inferiores a los de la angiografía por resonancia magnética, que fueron 91,89 %, 90,48 %, 57,14 % y 97,14 %, respectivamente. De las técnicas de imagen no invasivas, la ecografía de la arteria vertebral no caracteriza con precisión la estenosis de la arteria vertebral y su grado de estenosis. La angiografía por resonancia magnética detecta eficazmente la estenosis de la arteria vertebral y su grado de estenosis, y puede usarse como una herramienta confiable para la estenosis de la arteria vertebral en el infarto cerebral de circulación posterior, y puede ser utilizada junto con la angiografía por sustracción digital para mejorar el diagnóstico y la exactitud.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Insuficiência Vertebrobasilar/diagnóstico por imagem , Angiografia Digital , Ultrassonografia , Angiografia por Ressonância Magnética , Valor Preditivo dos Testes , Sensibilidade e Especificidade
6.
Respirar (Ciudad Autón. B. Aires) ; 16(1): 23-30, Marzo 2024.
Artigo em Espanhol | LILACS, UNISALUD, BINACIS | ID: biblio-1551185

RESUMO

Introducción: La EBUS ha sido el foco de numerosos estudios destinados a evaluar su utilidad y rendimiento diagnóstico en diversas patologías. Objetivo principal: Identificación de las características ganglionares evaluadas en el procedimiento de Ultrasonido Endobronquial (EBUS) y su relación con el diagnóstico de malignidad en pacientes del Instituto Nacional del Cáncer de Colombia del 1 de enero de 2017 al 31 de marzo de 2021.Métodos: Estudio analítico observacional transversal. La recopilación de datos implicó un muestreo de casos consecutivos no probabilísticos entre individuos que cumplían los criterios de inclusión.Resultados: Un total de 75 pacientes fueron sometidos a EBUS. Se identificaron 6 características ecográficas de los ganglios de la biopsia asociadas a malignidad destacándose los ganglios mayores de 1 cm, márgenes mal definidos, ecogenicidad heterogénea, ausencia de una estructura hiliar central, presencia de signos de necrosis o coagulación y presencia de conglomerado ganglionar. Conclusión: Este estudio caracterizó la frecuencia de los hallazgos en la ultrasonografía endobronquial destacando algunas características ecográficas de los ganglios mediastínicos que podrían predecir patología maligna.


Introduction: The EBUS has been the focus of numerous studies aiming to evaluate its utility and diagnostic performance across various pathologies. Objective: Identification of the node characteristics evaluated in the Endobronchial Ultrasound (EBUS) procedure and their relationship with malignancy diagnosis in patients at the National Cancer Institute of Colombia from January 1st, 2017, to March 31st, 2021. Methods: Observational cross-sectional analytical study. Data collection involved non-probabilistic consecutive case sampling among individuals meeting the inclusion criteria.Results: A total of 75 patients underwent the EBUS procedure. Our findings revealed six predictors of malignancy based on sonographic features of biopsy nodes, including nodes larger than 1 cm, poorly defined margins, heterogeneous echogenicity, absence of a central hilar structure, presence of signs indicating necrosis or coagulation, and the presence of a ganglion conglomerate. Conclusions: This study showed that endobronchial ultrasonography has several sonographic characteristics at the time of evaluating mediastinal nodes that could predict malignant and benign pathology.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Linfadenopatia/patologia , Neoplasias Pulmonares/diagnóstico , Linfonodos/diagnóstico por imagem , Neoplasias do Mediastino/diagnóstico , Biópsia/métodos , Ultrassonografia/métodos , Colômbia , Estadiamento de Neoplasias/métodos
7.
Alerta (San Salvador) ; 7(1): 42-49, ene. 26, 2024. graf, tab
Artigo em Espanhol | BISSAL, LILACS | ID: biblio-1526703

RESUMO

Introducción. El Síndrome del túnel carpiano es la neuropatía periférica compresiva más común de la extremidad superior, que se produce por la compresión del nervio mediano. Los casos leves y moderados pueden tratarse con métodos conservadores como ultrasonido terapéutico o infiltración con corticoesteroides. Objetivo. Describir la evolución clínica de pacientes con síndrome de túnel carpiano tratados con terapia por ultrasonido e infiltración de corticoesteroides. Metodología. Ensayo clínico abierto, en pacientes con síndrome del túnel carpiano leve y moderado, que consultaron del 1 de octubre 2021 al 30 de mayo 2022. Se formaron dos grupos; el que recibió tratamiento con ultrasonido con 12 casos y el grupo tratado con infiltración con corticoesteroides con seis casos. Ambos grupos fueron intervenidos en la consulta inicial, y luego, en las cuatro y ocho semanas posteriores al inicio del tratamiento. Resultados. Se muestran los resultados descriptivos relacionados con la intensidad de dolor, valorada con la Escala Visual Numérica, la infiltración obtuvo dos casos sin dolor y cuatro con dolor moderado, contrario a ultrasonido que se mantuvo con cuatro casos leves, tres moderados y cinco intensos. En los síntomas, la infiltración redujo el número de casos en cuatro de los síntomas estudiados, en cambio el ultrasonido únicamente en dos. En severidad, valorada con el cuestionario de Boston para túnel carpal, con infiltración se obtuvieron dos casos asintomáticos y ninguno con ultrasonido. Respecto a los signos clínicos, el signo de Tinel desapareció en cuatro casos en ambos grupos, mientras que signo de Phalen desapareció en cuatro casos en ultrasonido y dos en infiltración. Conclusión. En intensidad de dolor y grado de severidad, la infiltración generó casos asintomáticos y redujo mayor cantidad de síntomas que el ultrasonido. Ambos tratamientos disminuyeron la presencia de signos clínicos


Introduction. Carpal tunnel syndrome is the most common compressive peripheral neuropathy of the upper extremity, which is caused by compression of the median nerve. Mild and moderate cases can be treated with conservative methods such as therapeutic ultrasound or corticosteroid infiltration. Objective. To describe the clinical evolution of patients with carpal tunnel syndrome treated with ultrasound therapy and corticosteroid infiltration. Methodology. A prospective open clinical trial was conducted in patients with mild and moderate carpal tunnel syndrome who consulted from October 1, 2021 to May 30, 2022. Two groups were formed: the group that received ultrasound treatment with 12 cases and the group treated with corticosteroid infiltration with six cases. Both groups were treated at the initial consultation and then at four and eight weeks after the start of treatment. Results. The descriptive results related to the intensity of pain, evaluated with the Visual Numeric Scale, are shown. Infiltration obtained two cases without pain and four with moderate pain, contrary to ultrasound which was maintained with four mild, three moderate and five intense cases. In symptoms, infiltration reduced the number of cases in four of the symptoms studied, while ultrasound reduced the number of cases in only two. In severity, assessed with the Boston carpal tunnel questionnaire, with infiltration, there were two asymptomatic cases and none with ultrasound. Regarding clinical signs, Tinel's sign disappeared in four cases in both groups, while Phalen's sign disappeared in four cases in ultrasound and two in infiltration. Conclusion. Infiltration produced asymptomatic patients and reduced more symptoms than ultrasonography in terms of pain intensity and severity. Clinical symptoms were less common with both treatments.


Assuntos
El Salvador
8.
Texto & contexto enferm ; 33: e20230236, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS, BDENF - Enfermagem | ID: biblio-1560560

RESUMO

ABSTRACT Objective: to understand how ultrasound tools are used in prenatal Nursing consultations from the perspective of obstetric nurses. Method: a descriptive and qualitative study carried out with ten obstetric nurses that use obstetric ultrasound in their Nursing consultations at a maternity hospital in Belo Horizonte, Minas Gerais, Brazil. Individual, semi-structured interviews were conducted between December 1st and 4th, 2021. The Atlas.ti software was employed to process the results using Bardin's thematic content analysis. Results: the obstetric nurses expanded comprehensive care for pregnant women by implementing the use of ultrasound technology during Obstetric Nursing consultations, thus innovating the practices in Brazil. However, they faced countless challenges, which they overcame thanks to the positive results of improving obstetric and fetal care. Conclusion: using ultrasound technology in Obstetric Nursing consultations represents an advance in the Nursing practice, as it enables access and qualification to timely care, free of charge and through the Unified Health System. The support and encouragement of the institutional management strengthened obstetric nurses' professional autonomy, mediating the implementation of innovation. The study focus is added to the technological development employed in the everyday work of Brazilian Nursing, increasing resoluteness of decision-making in health problems.


RESUMEN Objetivo: comprender cómo se utiliza la herramienta de ultrasonido en consultas de Enfermería prenatal, según la opinión de enfermeras especializadas en Obstetricia. Método: estudio descriptivo de enfoque cualitativo, realizado en una maternidad de Belo Horizonte, Minas Gerais, Brasil, con diez enfermeras(os) especializadas(os) en Obstetricia que utilizan ultrasonido obstétrico en consultas de Enfermería. Se llevaron a cabo entrevistas individuales y semiestructuradas entre el 1 y el 4 de diciembre de 2021. Se utilizó el programa de software Atlas.ti para procesar los resultados por medio de análisis temático de contenido según Bardin. Resultados: las enfermeras especializadas en Obstetricia ampliaron la atención integral provista a las embarazadas, implementando el uso de la tecnología de ultrasonido durante las consultas de Enfermería Obstétrica, innovando así las prácticas de la profesión en Brasil. No obstante, enfrentaron innumerables desafíos, que fueron superados gracias a los resultados positivos de calificación de la atención obstétrica y fetal. Conclusión: utilizar la tecnología de ultrasonido en consultas de Enfermería Obstétrica representa un avance en la práctica de Enfermería, puesto que permite acceder y calificar los cuidados en tiempo y forma, de manera gratuita y a través del Sistema Único de Salud. El apoyo e incentivo por parte de la gerencia institucional fortalecieron la autonomía profesional de las enfermeras especializadas en Obstetricia, mediando la implementación de la innovación. El punto central del estudio se suma al desarrollo tecnológico empleado en la rutina de trabajo de los profesionales de Enfermería en Brasil, expandiendo así la capacidad de resolución del proceso de toma de decisiones relacionado con problemas de salud.


RESUMO Objetivo: compreender o uso da ferramenta ultrassonográfica na consulta de enfermagem de pré-natal sob a perspectiva das enfermeiras obstétricas. Método: estudo descritivo, de abordagem qualitativa, realizado em uma maternidade de Belo Horizonte, Minas Gerais, Brasil, com dez enfermeiras(os) obstétricas(os) que utilizam a ultrassonografia obstétrica na consulta de enfermagem. Entrevista individual, semiestruturada, realizada entre 1º e 4 de dezembro de 2021. Utilizou-se o software Atlas.ti para o tratamento dos resultados por meio da análise de conteúdo temática de Bardin. Resultados: as enfermeiras obstétricas ampliaram o cuidado integral às gestantes, implementando a utilização da tecnologia ultrassonográfica durante a consulta de enfermagem obstétrica, inovando as práticas no Brasil. Entretanto, enfrentaram inúmeros desafios, que foram superados graças aos resultados positivos de qualificação do cuidado obstétrico e fetal. Conclusão: a utilização da tecnologia ultrassonográfica na consulta de enfermagem obstétrica significa um avanço na prática de enfermagem, pois possibilita acesso e qualificação ao cuidado em tempo oportuno, gratuitamente, pelo Sistema Único de Saúde. O apoio e o incentivo da gestão institucional fortaleceram a autonomia profissional das enfermeiras obstétricas, mediando a implementação da inovação. O foco do estudo soma-se ao desenvolvimento tecnológico empregado no cotidiano de trabalho da enfermagem brasileira, ampliando a resolubilidade da tomada de decisão aos agravos à saúde.

9.
Texto & contexto enferm ; 33: e20230287, 2024. tab
Artigo em Inglês | LILACS-Express | LILACS, BDENF - Enfermagem | ID: biblio-1565922

RESUMO

ABSTRACT Objective: to assess the incidence of complications related to peripherally inserted central catheters in hospitalized adult patients with Covid-19 and to discuss the potential benefits of employing insertion technologies to prevent complications. Method: a descriptive, exploratory and cross-sectional study was conducted from March 2020 to December 2021 at a high-complexity hospital. The study included patients over 18 years old with a positive diagnosis for Covid-19 who made use of peripherally inserted central catheters for venous infusion. Data collection included sociodemographic and clinical information regarding catheter insertion and use. The analysis involved Chi-square and Fisher's Exact tests, with a significance level of 0.05. Results: a total of 123 inserted catheters were analyzed. The patients' mean age was 50 years old (SD=16.37), most of them male and in the acute phase of infection (59.3%). The following significant complications related to the insertion process were identified: catheter material (p=0.01); use of Sherlock (p=0.03); need for traction (p<0.001); number of punctures (p<0.001); and difficulty in catheter progression (p<0.001). Conclusion: the study identified the main complications related to the insertion and use of PICCs and showed that employing vascular visualization technologies such as ultrasound and Sherlock 3CG® can mitigate complications, as well as maximize patient comfort, experience and safety. The research provides support for the implementation of protocols for insertion and management of peripherally inserted central catheters, thus avoiding the occurrence of adverse events.


RESUMEN Objetivo: evaluar la incidencia de complicaciones relacionadas a catéteres centrales de inserción periférica en pacientes adultos hospitalizados con Covid-19 y debatir el potencial de emplear tecnologías de inserción en la prevención de complicaciones. Método: estudio descriptivo, exploratorio y transversal, realizado entre marzo de 2020 y diciembre de 2021 en un hospital de alta complejidad. En el estudio se incluyó a pacientes mayores de 18 años con diagnóstico positivo de Covid-19 y que utilizaran catéteres centrales de inserción periférica para infusiones venosas. Se recolectaron datos sociodemográficos y clínicos sobre la inserción y el uso de los catéteres. El análisis implicó las pruebas de Chi-cuadrado y Exacta de Fischer, con 0,05 como nivel de significancia. Resultados: se analizó un total de 123 catéteres insertados. La media de edad de los pacientes fue de 50 años (DE=16,37), con mayoría del sexo masculino y en la fase aguda de la infección (59,3%). Se hicieron evidentes las siguientes complicaciones significativas vinculadas al proceso de inserción: material del catéter (p=0,01), uso de Sherlock (p=0,03), necesidad de tracción (p<0,001), cantidad de punciones (p<0,001) y dificultad de avance del catéter (p<0,001). Conclusión: el estudio identificó las principales complicaciones relacionadas a la inserción y el uso de catéteres PICC y demostró que utilizar tecnologías de visualización vascular como ultrasonido y Sherlock 3CG® puede mitigar las complicaciones, además de maximizar la comodidad, experiencia y seguridad del paciente. El trabajo de investigación presenta aportes para implementar protocolos de inserción y manejo de los catéteres centrales de inserción periférica, evitando así la incidencia de eventos adversos.


RESUMO Objetivo: avaliar a incidência de complicações relacionadas ao cateter central de inserção periferica em pacientes adultos hospitalizados com Covid-19 e discutir o potencial do uso de tecnologias de inserção na prevenção de complicações. Método: estudo descritivo e exploratório, transversal, realizado no período de março de 2020 a dezembro de 2021, em um hospital de alta complexidade. Foram incluídos no estudo pacientes maiores de 18 anos com diagnóstico positivo para Covid-19 e que fizeram uso do cateter central de inserção periférica para infusão venosa. Fez-se coleta de dados sociodemográficos e clínicos sobre a inserção e uso do cateter. A análise envolveu os testes qui-quadrado e exato de Fischer, com nível de significância de 0,05. Resultados: analisou-se um total de 123 cateteres inseridos. A média de idade dos pacientes foi de 50 anos (DP=16,37 anos), sendo a maioria do sexo masculino e na fase aguda da infecção (59,3%). Foram evidenciadas as seguintes complicações significativas atreladas ao processo de inserção: material do cateter (p=0,01), uso de Sherlock (p=0,03), necessidade de tração (p<0,001), número de punções (p<0,001) e dificuldade de progressão do cateter (p<0,001). Conclusão: o estudo identificou as principais complicações relacionadas à inserção e uso do PICC e mostrou que o uso de tecnologias de visualização vascular como o ultrassom e Sherlock 3CG® pode mitigar complicações, além de maximizar conforto, experiência e segurança do paciente. A investigação apresenta subsídios para implementação de protocolos de inserção e manejo do cateter central de inserção periférica, evitando a ocorrência de eventos adversos.

10.
Rev. cuba. inform. méd ; 15(2)dic. 2023.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1536284

RESUMO

En diciembre de 2019 las Autoridades de la República Popular China, comunicaron a la OMS varios casos de neumonía de etiología desconocida en Wuhan, una ciudad situada en la provincia china de Hubei. Una semana más tarde confirmaron que se trataba de un nuevo coronavirus que fue denominado SARS-CoV-2, este virus causa diversas manifestaciones clínicas englobadas bajo el término COVID-19. El presente trabajo presenta un prototipo de aplicación con el nombre UDC-COVID19 que propone una herramienta digital sobre la base de una revisión actualizada de la evaluación ultrasonográfica del diafragma como elemento predictivo para retirar la ventilación mecánica invasiva en pacientes con COVID-19, proporcionando una excelente herramienta digital para la evaluación de la estructura y función dinámica diafragmática, es precisa, reproducible, sin radiación ionizante, fácil de realizar a la cabecera del paciente y costo efectiva en pacientes críticamente enfermos.


In December 2019, the Authorities of the People's Republic of China reported to the WHO several cases of pneumonia of unknown etiology in Wuhan, a city located in the Chinese province of Hubei. A week later, they confirmed that it was a new coronavirus called SARS-CoV-2, which causes various clinical manifestations encompassed under the term COVID-19. The present work presents an application prototype with the name UDC-COVID19 that proposes a digital tool based on an updated review of the ultrasonographic evaluation of the diaphragm as a predictive element to withdraw invasive mechanical ventilation in patients with COVID-19, providing an excellent digital tool for the evaluation of the diaphragmatic structure and dynamic function since it is precise, reproducible, without ionizing radiation, easy to perform at the patient's bedside and cost effective in critically ill patients; mechanical ventilation.

11.
Bol. méd. Hosp. Infant. Méx ; 80(6): 361-366, Nov.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527964

RESUMO

Abstract Background: Lung ultrasound is a bedside tool that allows the evaluation of pulmonary parenchymal involvement in pediatric patients through the lung ultrasound score (LUS). We aimed to evaluate a group of patients under 3 years of age with lower respiratory tract infections using LUS at the Hospital Infantil del Estado de Sonora. Methods: We included patients younger than 3 years admitted to the emergency department with lower respiratory tract infections. A lung ultrasound was performed within the first 24 h of admission to the emergency department and evaluated using LUS. We analyzed age, sex, etiology of infection, days of stay, use of mechanical ventilation, Downes scale, failure of mechanical ventilation on admission, and mortality. Descriptive analysis was performed with frequencies and percentages for qualitative variables and medians and interquartile intervals for quantitative variables. Differences in the distribution of LUS variables were evaluated with the Fishers´ exact test and Student´s t-test. Results: We included a total of 19 patients with lower respiratory tract infections, 73.7% with bronchiolitis. Fifty percent of the cases scored 7 on the LUS, 91.7% were admitted to the pediatric intensive care unit, and 53.8% required invasive mechanical ventilation. Conclusions: The use of LUS in lower respiratory tract infections can predict the need for PICU admission, the use of invasive ventilatory support, and prolonged hospital stay.


Resumen Introducción: El ultrasonido pulmonar es una herramienta a pie de cama que permite evaluar la afectación del parénquima pulmonar en pacientes pediátricos por medio de la escala de LUS (lung ultrasound score, por sus siglas en inglés). El objetivo del estudio fue evaluar a niños menores de 3 años con infección respiratoria baja mediante la escala de LUS, en el Hospital Infantil del Estado de Sonora. Métodos: Se incluyeron pacientes menores de 3 años que ingresaron al Servicio de Urgencias con infección respiratoria baja. Se realizó ecografía pulmonar en las primeras 24 horas de ingreso a urgencias y se evaluó mediante la escala de LUS. Se analizó, edad, sexo, etiología de la infección, días de estancia, uso de terapia ventilatoria, escala de Downes, fracaso a la terapia ventilatoria de ingreso y mortalidad. Se realizó un análisis descriptivo por medio de frecuencia y porcentaje para las variables cualitativas y para las cuantitativas con mediana e intervalo intercuartil. Las diferencias en la distribución de las variables por la escala de LUS con la prueba exacta de Fisher y la t de Student. Resultados: Se identificaron 19 pacientes con infección pulmonar aguda, de los cuales el 73.7% presentó bronquiolitis. El 50% de los casos obtuvo 7 puntos de la escala de LUS, el 91.7% ingresó a UCIP y el 53.8% requirió ventilación mecánica asistida. Conclusiones: El uso de la escala LUS en infección respiratoria baja puede predecir la necesidad de ingreso a Unidad de Cuidados Intensivos Pediátricos, así como la utilización de soporte ventilatorio invasivo y una estancia hospitalaria prolongada.

12.
Rev. méd. Urug ; 39(4): e203, dic. 2023.
Artigo em Espanhol | LILACS, BNUY | ID: biblio-1530275

RESUMO

Objetivo: presentar la utilización de la guía ecográfica en el tórax para realizar biopsias y colocación de drenajes, ya sean pleurales o pericárdicos. Material y método: se realizaron 124 procedimientos ecoguiados en el Instituto del Tórax del Hospital Maciel, desde enero de 2014 hasta agosto de 2022. Resultados: se evaluaron franja etaria, tipo de procedimiento y rentabilidad diagnóstica en los procedimientos ecoguiados. Se realizaron 69 punciones con fines diagnósticos, 48 colocaciones de drenajes pleurales bajo apoyo ecográfico y 7 drenajes pericárdicos. Conclusión: la realización de procedimientos ecoguiados en el tórax es una herramienta diagnóstica y terapéutica segura, con buen rendimiento y mínimas complicaciones.


Objective: To present the use of ultrasound guidance to perform thorax biopsies and place drainages, whether pleural or pericardial. Method: A total of 124 ultrasound-guided procedures were performed at the Thoracic Institute, Maciel Hospital, from January 2014 to August 2022. Results: The results were assessed based on age group, type of procedure, and diagnostic yield in the ultrasound-guided procedures. There were 69 diagnostic punctures, 48 ultrasound-guided pleural drainage placements, and 7 pericardial drainages. Conclusions: The performance of ultrasound-guided thoracic procedures are a safe diagnostic and therapeutic tool with excellent efficacy and minimal complications.


Objetivo: fica no tórax para realização de biópsias e colocação de drenos pleurais ou pericárdicos. Materiais e métodos: foram realizados 124 procedimentos guiados por ultrassom no Instituto del Tórax do Hospital Maciel no período de janeiro de 2014 a agosto de 2022. Resultados: foram avaliadas faixa etária, tipo de procedimento e rentabilidade diagnóstica em procedimentos guiados por ultrassom. Foram realizadas 69 punções para fins diagnósticos, 48 colocações de drenos pleurais sob suporte ultrassonográfico e 7 drenos pericárdicos. Conclusão: a realização de procedimentos guiados por ultrassom no tórax é uma ferramenta diagnóstica e terapêutica segura, com bom desempenho e complicações mínimas.


Assuntos
Punções , Ultrassonografia de Intervenção , Cirurgia Torácica Vídeoassistida , Cirurgia Torácica
13.
rev. udca actual. divulg. cient ; 26(2): e2437, jul.-dic. 2023. tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1576968

RESUMO

RESUMEN Existen varias metodologías para determinar la condición corporal del caballo deportivo, siendo unas más objetivas que otras; sin embargo, la escala de condición corporal es la más usada para estimar las reservas corporales de animales en actividad atlética. El objetivo del estudio fue estimar, por métodos no invasivos, el espesor de grasa subcutánea y desarrollo muscular de caballos deportivos, de una academia de Cundinamarca y calcular algunos índices que definen la composición corporal. Se escogieron 29 caballos adultos (9 hembras, 20 machos), de cuatro tipos raciales; caballo deporte colombiano, criollo, polo argentino, Pura sangre inglés. Para evaluar la grasa subcutánea se usó el puntaje de condición corporal (PCC) escala Henneke, el ultrasonido en tiempo real UTR, midiendo espesor de grasa dorsal y de cadera. La musculatura se determinó usando UTR a nivel dorsal, midiendo el ojo del lomo y el glúteo medio. Se tomaron pesos y medidas morfométricas: altura de cruz, longitud corporal, perímetro torácico. Con estas medidas corporales o ecográficas se calcularon índices de desempeño o composición corporal: índice corporal (IC), índice de carga al paso-1 y al trote-2 (IC1 y IC2), % de grasa corporal (%GC), Índice de masa corporal (IMC), relación perímetro torácico-altura cruz (PT:AC), índice muscular (IM) e índice musculoesquelético (IME). Los índices de carga y de composición corporal indicaron diferencias entre tipos raciales (p<0,05). Entre índices de engrasamiento se presentaron correlaciones altas con PCC (EGD 0,78 y IMC 0,99). Algunos índices (IC1, IC2) serían indicadores indirectos de la relación fin-bienestar en los animales.


ABSTRACT There are several methodologies to determine the body condition of the sport horse, some being more objective than others, however the body condition score scale is the most used to estimate the body reserves of animals in athletic activity. The aim of the research was to estimate by non-invasive methods the thickness of subcutaneous fat and muscle development of horses from an equestrian school; and to calculate indexes that define the horse's body composition. 29 adult horses (9 females, 20 males) of four racial types were selected; Colombian sport horse, criollo, Argentine polo and English Thoroughbred. To assess subcutaneous fat, Henneke scale body condition score (BCS) was used, along with real-time ultrasound RTU measuring the back fat thickness (BFT) and croup fat thickness (CFT). Musculature was measured using UTR at the T17-T18 level, measuring the Ribeye area and the thickness of the gluteus medius. Additionally, weight (BW) and morphometric measurements were taken: wither height (WH), body-length (BL), girth circumference (GC). From these body or ultrasound measurements some performance indexes were calculated and/or body composition: body index (BI), load index at step and trot (LIS and LIT), % body fat (%BF), Body mass index (BMI), girth circumference ratio-height (GC: WH, muscle index (MI) and musculoskeletal index (MEI). Load indexes and body composition indicated differences between racial types (p<0.05). Between indexes that estimate fatness, there were significant correlations with BCS BFT 0,78 and BMI 0,99). Some indexes (LIS, LIT) would be indirect indicators of the aptitude-welfare relationship in animals.

14.
Bol Med Hosp Infant Mex ; 80(6): 361-366, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38150713

RESUMO

BACKGROUND: Lung ultrasound is a bedside tool that allows the evaluation of pulmonary parenchymal involvement in pediatric patients through the lung ultrasound score (LUS). We aimed to evaluate a group of patients under 3 years of age with lower respiratory tract infections using LUS at the Hospital Infantil del Estado de Sonora. METHODS: We included patients younger than 3 years admitted to the emergency department with lower respiratory tract infections. A lung ultrasound was performed within the first 24 h of admission to the emergency department and evaluated using LUS. We analyzed age, sex, etiology of infection, days of stay, use of mechanical ventilation, Downes scale, failure of mechanical ventilation on admission, and mortality. Descriptive analysis was performed with frequencies and percentages for qualitative variables and medians and interquartile intervals for quantitative variables. Differences in the distribution of LUS variables were evaluated with the Fishers' exact test and Student's t-test. RESULTS: We included a total of 19 patients with lower respiratory tract infections, 73.7% with bronchiolitis. Fifty percent of the cases scored 7 on the LUS, 91.7% were admitted to the pediatric intensive care unit, and 53.8% required invasive mechanical ventilation. CONCLUSIONS: The use of LUS in lower respiratory tract infections can predict the need for PICU admission, the use of invasive ventilatory support, and prolonged hospital stay.


INTRODUCCIÓN: El ultrasonido pulmonar es una herramienta a pie de cama que permite evaluar la afectación del parénquima pulmonar en pacientes pediátricos por medio de la escala de LUS (lung ultrasound score, por sus siglas en inglés). El objetivo del estudio fue evaluar a niños menores de 3 años con infección respiratoria baja mediante la escala de LUS, en el Hospital Infantil del Estado de Sonora. MÉTODOS: Se incluyeron pacientes menores de 3 años que ingresaron al Servicio de Urgencias con infección respiratoria baja. Se realizó ecografía pulmonar en las primeras 24 horas de ingreso a urgencias y se evaluó mediante la escala de LUS. Se analizó, edad, sexo, etiología de la infección, días de estancia, uso de terapia ventilatoria, escala de Downes, fracaso a la terapia ventilatoria de ingreso y mortalidad. Se realizó un análisis descriptivo por medio de frecuencia y porcentaje para las variables cualitativas y para las cuantitativas con mediana e intervalo intercuartil. Las diferencias en la distribución de las variables por la escala de LUS con la prueba exacta de Fisher y la t de Student. RESULTADOS: Se identificaron 19 pacientes con infección pulmonar aguda, de los cuales el 73.7% presentó bronquiolitis. El 50% de los casos obtuvo 7 puntos de la escala de LUS, el 91.7% ingresó a UCIP y el 53.8% requirió ventilación mecánica asistida. CONCLUSIONES: El uso de la escala LUS en infección respiratoria baja puede predecir la necesidad de ingreso a Unidad de Cuidados Intensivos Pediátricos, así como la utilización de soporte ventilatorio invasivo y una estancia hospitalaria prolongada.


Assuntos
Pulmão , Infecções Respiratórias , Humanos , Criança , Pulmão/diagnóstico por imagem , Respiração Artificial , Infecções Respiratórias/diagnóstico por imagem , Hospitalização , Serviço Hospitalar de Emergência
15.
Rev Med Inst Mex Seguro Soc ; 61(Suppl 3): S445-S452, 2023 Oct 02.
Artigo em Espanhol | MEDLINE | ID: mdl-37934911

RESUMO

Background: The use of local anesthetics as part of multimodal analgesia is an attractive concept in pediatric patients, since the evaluation and management of pain is a challenge in children under 7 years of age. Despite having guidelines and multiple studies on volume calculation, no safe and effective recommendation has been issued. Objective: To demonstrate that ultrasound-guided caudal block with a dose of 0.75 mL/kg of 0.2% ropivacaine has the same analgesic effect as a dose of 1.2 mL/kg. Material and methods: Randomized, prospective, longitudinal, comparative equivalence clinical trial. One hundred patients 0-7 years of age scheduled for elective or emergency infraumbilical surgery were enrolled between April 2021 and January 2022. Children were randomized 1:1 to be assigned to ultrasound-guided caudal block. Results: 100 patients divided into two groups with 0.2% ropivacaine volumes (0.75 mL vs. 1.2 mL). Both groups demonstrated the trans-anesthetic and post-anesthetic sedoanalgesia variables without significant differences for both groups on the FLACC pain scale after surgery and in recovery (p > 0.5), in the pain reassessment on the FLACC scale in the office called chronic pain (p > 0.5) in both groups. No complications were reported in the follow-up consultations and no arrhythmias were reported in both groups during surgery. Conclusions: the results of both groups did not show differences between a volume of 0.75 mL and 1.2 mL, the administration of 0.2% ropivacaine is favored with the use of ultrasound, which allows effective administration of lower doses of local anesthetic with reduced risk of complications. It is necessary to carry out studies in other types of surgery to compare the use of less volume of local anesthetic compared to the Melman formula used in this study.


Introducción: el uso de anestésicos locales como parte de la analgesia multimodal es un concepto atractivo en pacientes pediátricos, ya que la evaluación y manejo del dolor es un reto en menores de 7 años. A pesar de contar con guías y múltiples estudios del cálculo de volumen no se ha emitido una recomendación segura y eficaz. Objetivo: demostrar que el bloqueo caudal ecoguiado con dosis de 0.75 mL/kg de ropivacaína 0.2% tiene el mismo efecto analgésico que la dosis de 1.2 mL/kg. Material y métodos: ensayo clínico aleatorizado de equivalencia, prospectivo, longitudinal, comparativo. Se enrolaron 100 pacientes de 0-7 años programados para cirugía infraumbilical electiva o de urgencia entre abril del 2021 y enero del 2022. Los niños fueron aleatorizados 1:1 para asignarse a la realización del bloqueo caudal guiado por ultrasonido. Resultados: de los 100 pacientes divididos en dos grupos con volúmenes de ropivacaína 0.2% (0.75 mL frente a 1.2 mL). Ambos grupos demostraron las variables de sedoanalgesia transanestésicas y postanestésicas sin diferencias significativas para ambos grupos en la escala de FLACC de dolor después de la cirugía y en recuperación (p > 0.5), en la revaloración de dolor en la escala de FLACC en el consultorio denominado dolor crónico (p > 0.5) en ambos grupos. No se reportaron complicaciones en las consultas de seguimiento y tampoco arritmias en ambos grupos durante la cirugía. Conclusiones: los resultados en ambos grupos no mostraron diferencias entre un volumen de 0.75 mL y 1.2 mL, la administración de ropivacaina 0.2% se favorece con el empleo de ultrasonido, lo que permite administración eficaz de dosis menores de anestésico local con reducción del riesgo de complicaciones. Es necesario realizar estudios en otros tipos de cirugía para comparar el uso de menos volumen de anestésico local frente a la fórmula de Melman que ocupamos en este estudio.


Assuntos
Anestésicos Locais , Ultrassonografia de Intervenção , Criança , Humanos , Ropivacaina , Estudos Prospectivos , Ultrassonografia de Intervenção/métodos , Dor , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle
16.
Rev Gastroenterol Mex (Engl Ed) ; 88(4): 381-391, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37833134

RESUMO

Point-of-care ultrasound (POCUS) refers to the use of ultrasound imaging through pocket-sized sonographic devices at the patient's bedside, to make a diagnosis or direct a procedure and immediately answer a clinical question. Its goal is to broaden the physical examination, not to replace conventional ultrasound studies. POCUS has evolved as a complement to physical examination and has been adopted by different medical specialties, including hepatology. A narrative synthesis of the evidence on the applications of POCUS in hepatology was carried out, describing its usefulness in the diagnosis of cirrhosis of the liver, metabolic dysfunction-associated steatotic liver disease (MASLD), decompensated cirrhosis, and portal hypertension. The review also encompasses more recent applications in the hemodynamic evaluation of the critically ill patient with cirrhosis of the liver, patients with other liver diseases, as well as in the ultrasound guidance of procedures. POCUS could make up part of the daily clinical practice of gastroenterologists and hepatologists, simplifying the initial evaluation of patients and optimizing clinical management. Its accessibility, ease of use, and low adverse event profile make POCUS a useful tool for the properly trained physician in the adequate clinical setting. The aim of this review was to describe the available evidence on the usefulness of POCUS in the daily clinical practice of gastroenterologists and hepatologists.


Assuntos
Gastroenterologia , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Ultrassonografia/métodos , Cirrose Hepática , Exame Físico
17.
Cir Cir ; 91(5): 633-640, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37844890

RESUMO

OBJECTIVE: The aim of this study was compare the palpation technique and ultrasound-guidance for femoral artery catheterization in pediatric patients undergoing surgery for congenital heart disease. MATERIALS AND METHODS: This prospective and randomized controlled study included American Society of Anesthesiologists III-IV 40 children who underwent congenital heart surgery. The patients were divided into two groups; ultrasound-guided catheterization group and palpation-guided catheterization group. Demographic and clinical characteristics of the patients, access time, success rate, number of attempts, first-attempt success, number of trials, and failed cannulations were recorded. RESULTS: The diameter of the femoral artery was significantly shorter, access time and numbers of trials were significantly lower, and first-attempt success rate was significantly higher in the US group. The complication rate was significantly higher in the P group. The number of failed catheterization was higher in the P group. Total cost required for the procedure was significantly lower in the US group. CONCLUSION: We found that ultrasound-guided arterial catheterization increases the success rate and the number of successful catheterizations, while reducing the overall procedure time, incidence of complications, and cost. Therefore, we believe that the use of ultrasound guidance in arterial catheterization in pediatric cardiac surgery would be a better choice.


OBJETIVO: El objetivo de este estudio fue comparar la técnica de palpación y ecoguiado para el cateterismo de la arteria femoral en pacientes pediátricos operados de cardiopatías congénitas. MATERIALES Y MÉTODOS: Este estudio prospectivo, aleatorizado y controlado incluyó a 40 niños ASA III-IV que se sometieron a cirugía cardíaca congénita. Los pacientes se dividieron en 2 grupos; Grupo de cateterismo guiado por ecografía y grupo de cateterismo guiado por palpación. RESULTADOS: El diámetro de la arteria femoral fue significativamente más corto, el tiempo de acceso y el número de intentos fueron significativamente menores y la tasa de éxito del primer intento fue significativamente mayor en grupo estadounidense. La tasa de complicaciones fue significativamente mayor en el grupo P. El número de cateterismos fallidos fue mayor en el grupo P. El costo total requerido para el procedimiento fue significativamente menor en el grupo de EE. CONCLUSIONES: Encontramos que el cateterismo arterial guiado por ultrasonido aumenta la tasa de éxito y el número de cateterismos exitosos, al tiempo que reduce el tiempo total del procedimiento, la incidencia de complicaciones y el costo. Por tanto, creemos que el uso de guía ecográfica en cateterismo arterial en cirugía cardiaca pediátrica sería una mejor opción.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cateterismo Periférico , Humanos , Criança , Artéria Femoral/diagnóstico por imagem , Estudos Prospectivos , Cateterismo Periférico/métodos , Ultrassonografia de Intervenção/métodos , Palpação
18.
Rev. medica electron ; 45(5)oct. 2023.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1522061

RESUMO

La caracterización antropométrica de los individuos aporta información para la evaluación de su estado de salud, en particular la composición corporal -aspecto esencial en la valoración nutricional y funcional-, donde el ultrasonido adquiere cada vez más valor en el análisis de estos componentes. El propósito de esta investigación es sistematizar los referentes sobre el estudio de la composición corporal a través de las mediciones del tejido adiposo subcutáneo por ultrasonido. Se realizó una investigación documental cuyo objeto de estudio fueron los artículos publicados en las bases de datos SciELO, EBSCO y PubMed, entre enero de 2020 y octubre de 2022. Se encontró que existen diferentes centros investigativos que han desarrollado estudios sobre la composición corporal medida a través de ultrasonido, mayormente en la última década. Las principales escuelas se encuentran en Francia, Estados Unidos, Brasil y Austria. Las aplicaciones de estos estudios se encuentran en la nutrición, el deporte, la salud en general, y poblaciones particulares como niños, adolescentes, militares e individuos con sobrepeso u obesidad. Por tanto, se considera que el ultrasonido es un método indirecto de medición de la composición corporal, que ha sido empleado para medir la estructura del tejido y ha demostrado ser una técnica precisa para medir el grosor de la grasa subcutánea.


The anthropometric characterization of individuals provides information for the evaluation of their health status, in particular body composition -a fundamental aspect in nutritional and functional assessment- where ultrasound acquires increasingly more value in the analysis of these components. The purpose of this study is to systematize the references on the study of body composition through measurements of subcutaneous adipose tissue by ultrasound. A documentary research was carried out whose object of study was the scientific articles published in the SciELO, EBSCO and PubMed databases, between January 2020 and October 2022. It was found that different research centers have developed studies on body composition measured through ultrasound, mainly in the last decade. The main schools are located in France, the United States, Brazil and Austria. The applications of these studies are found in nutrition, sports, health in general and in particular populations such as children, adolescents, military personnel, and overweight or obese individuals. Therefore, ultrasound is considered to be an indirect method of measuring body composition, which has been used to measure tissue structure and has proven to be an accurate technique for measuring the thickness of subcutaneous fat.

19.
Acta ortop. mex ; 37(5): 255-263, sep.-oct. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1573743

RESUMO

Abstract: Introduction: the management of adhesive capsulitis (AC) remains a topic of debate among orthopedic surgeons, with a wide variation in the literature. Conservative treatment relies as the first-line option as clinical studies report positive outcomes. However, there is variability in the effectiveness of different treatment modalities. Material and methods: this study aimed to analyzed functional and clinical outcomes of patients with AC who underwent the arthrodilation protocol, including three ultrasound-guided injections administered on a weekly basis: two corticosteroid injections and one injection of hyaluronic acid combined with corticosteroids. Additionally, patients received a specific rehabilitation therapy. Visual analogue scale (VAS), the university of California-Los Angeles shoulder score (UCLA) and Constant-Murley score were assessed before treatment and after 3-month follow-up period. Results: 23 patients were included, receiving the same treatment protocol with a mean onset of symptoms of 4.9 ± 1.7 months. Among these patients, there was a clear predominance of females (65.2%). Age distribution ranged from 39 to 74 years (mean = 56) indicating that individuals in their mid-50s were more susceptible to developing this condition. Furthermore, a slight majority (52.2%) exhibited AC in their right shoulder. VAS significantly decreased (-6.09 ± 1.9 [p ≤ 0.05]). Similarly, UCLA score (10.9 ± 2.9 to 31.7 ± 2.2) and Constant-Murley score (22.3 ± 6.1 to 62.0 ± 6.2) improved significantly. Pre-to-post treatment evaluation showed improvement in both UCLA (mean = 20.8 ± 2.9 [p ≤ 0.05]) and Constant-Murley (mean = 39.7 ± 9 [p ≤ 0.05]). Conclusion: arthrodilation protocol demonstrated promising results, with patients achieving good to excellent outcomes and safely resuming their regular daily activities within a short-term follow-up period. These findings provide support for arthrodilation as a viable conservative management option and contribute valuable insights to the ongoing research aimed at identifying optimal treatment approaches for adhesive capsulitis.


Resumen: Introducción: el tratamiento de la capsulitis adhesiva (CA) sigue siendo un tema de debate entre los cirujanos ortopedistas, con una variación amplia en la literatura. El tratamiento conservador se considera la opción de primera línea, ya que los estudios clínicos muestran resultados positivos. Sin embargo, existe variabilidad en la efectividad de las diferentes modalidades de tratamiento. Material y métodos: este estudio tuvo como objetivo analizar los resultados funcionales y clínicos de pacientes con CA que se sometieron al protocolo de artrodilatación, incluyendo tres inyecciones guiadas por ultrasonido administradas semanalmente: dos inyecciones de corticosteroides y una inyección de ácido hialurónico combinado con corticosteroides. Además, los pacientes recibieron una terapia de rehabilitación específica. La escala analógica visual (EVA), la puntuación del hombro de la Universidad de California-Los Ángeles (UCLA) y la puntuación de Constant-Murley se evaluaron antes del tratamiento y después de un período de seguimiento de tres meses. Resultados: se incluyeron 23 pacientes que recibieron el mismo protocolo de tratamiento con un inicio medio de síntomas de 4.9 ± 1.7 meses. Entre estos pacientes hubo un claro predominio del sexo femenino (65.2%). La distribución por edades osciló entre 39 y 74 años (media = 56), lo que indica que las personas de alrededor de 55 años eran más susceptibles a desarrollar esta afección. Además, una ligera mayoría (52.2%) presentaba CA en el hombro derecho. La EVA disminuyó significativamente (-6.09 ± 1.9 [p ≤ 0.05]). De manera similar, la puntuación de UCLA (10.9 ± 2.9 a 31.7 ± 2.2) y la puntuación de Constant-Murley (22.3 ± 6.1 a 62.0 ± 6.2) mejoraron significativamente. La evaluación previa y posterior al tratamiento mostró una mejoría tanto en UCLA (media = 20.8 ± 2.9 [p ≤ 0.05]) como en Constant-Murley (media = 39.7 ± 9 [p ≤ 0.05]). Conclusión: el protocolo de artrodilatación demostró resultados prometedores, los pacientes lograron resultados de buenos a excelentes y reanudaron de manera segura sus actividades diarias regulares dentro de un período de seguimiento a corto plazo. Estos hallazgos respaldan la artrodilatación como una opción de tratamiento conservador viable y aportan conocimientos valiosos a la continua investigación destinada a identificar tratamientos óptimos para la capsulitis adhesiva.

20.
Rev. Fed. Centroam. Ginecol. Obstet ; 27(2): 52-53, 10 de septiembre de 2023.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1532657

RESUMO

Se trata de paciente femenina, G1 de 21 años referida por sospecha de cardiopatía congénita (aurícula única). Durante la entrevista, no reporta antecedentes médicos relevantes. Se realiza ultrasonido fetal, revelando los siguientes hallazgos ultrasonográficos: Válvula tricúspide displásica, elongada, engrosada e hiperecogénica Desplazamiento apical de la valva septal de la válvula tricúspide. Ventrículo derecho con tamaño reducido Incremento en el septum inter-ventricular Atrio derecho incrementado de tamaño Efusión pericárdica Regurgitación (insuficiencia) tricúspidea significativa El chorro de la regurgitación de origen apical (provisto por Infomedic International)


The patient is a 21-year-old female patient, G1, referred for suspected congenital heart disease (single atrium). During the interview, she reported no relevant medical history. Fetal ultrasound was performed, revealing the following ultrasonographic findings: - Dysplastic, elongated, thickened and hyperechogenic tricuspid valve.- Apical displacement of the septal leaflet of the tricuspid valve. - Right ventricle with reduced size- Increased interventricular septum.- Cardiomegaly. - Increased right atrium size- Pericardial effusion- Significant tricuspid regurgitation (insufficiency).- Regurgitation jet of apical origin (provided by Infomedic International)

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA