Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
JACC Case Rep ; 29(13): 102389, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38912319

RESUMO

A patient presented with severe right heart failure due to a large LV-to-RA shunt with left-to-right shunting and torrential tricuspid regurgitation 6-weeks following surgical sub-aortic stenosis resection. Retrograde delivery of an Occlutech ventricular septal defect device produced instantaneous resolution of shunt, reduction in tricuspid regurgitation, and impressive diuresis of 28 kg.

2.
Interv Cardiol Clin ; 13(3): 399-408, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839172

RESUMO

Hybrid interventions in congenital heart disease (CHD) embody the inherent collaboration between congenital interventional cardiology and cardiothoracic surgery. Hybrid approaches to complex and common lesions provide the opportunity to circumvent the limitations of patient size, vascular access, severity of illness, and anatomy that would otherwise be prohibitive to surgical and percutaneous techniques alone. This review describes several important hybrid approaches to interventions in CHD.


Assuntos
Cardiopatias Congênitas , Humanos , Cardiopatias Congênitas/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos
3.
Cureus ; 16(3): e55530, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38444930

RESUMO

Ventricular septal defects (VSDs) are a prevalent congenital heart anomaly demanding safe and lasting interventions. This paper explores the application of Invengenx® bovine pericardial patch (Tisgenx, Irvine, California), a promising biomaterial, in VSD repair. We present two case studies: a seven-month-old infant and a three-year-old child undergoing VSD closure using autologous and bovine pericardial patches, respectively. Both patients tolerated the procedures well, experiencing no intra-operative complications and demonstrating excellent postoperative recovery. Echocardiography postoperatively showed no complications and improved clinical outcomes. Notably, the pericardial patches exhibited excellent integration and suture retention, highlighting their durability and compatibility with the growing heart. These cases establish the feasibility and effectiveness of the Invengenx® pericardial patch for VSD repair. The favorable outcomes in terms of safety and efficacy support the potential of this biomaterial as a valuable alternative in pediatric cardiac surgery, particularly for complex VSDs or patients with contraindications to synthetic patches. Further research is crucial to unlock the full potential of bovine pericardium as a durable and advantageous option for VSD repair in a broader range of pediatric patients.

4.
Cureus ; 15(7): e42591, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37641752

RESUMO

Background Ventricular septal defects (VSDs) are the most common type of septal defects in early infants and are very complicated. This has paved the way for the development of new minimally invasive procedures for interventional cardiologists. This study presents our experience using duct occluders instead of conventional ventricular septal devices in the Department of Cardiology at Acharya Vinoba Bhave Rural Hospital (AVBRH) in central rural India. This study aimed to review success and complications and assess safety and its relation to age, sex, size of the VSDs, type of VSD, and types of devices used after transcatheter closure of perimembranous and muscular VSDs using various types of duct occluders. Methodology This retrospective study included patients who underwent percutaneous VSD device closure at the AVBRH between July 2017 and December 2020. We reviewed the patients' medical records to recognize imaging, clinical, and interventional data pre- and post-procedure and at the last follow-up. Results The success rate of VSD closure was 98.6%, one (0.7%) out of 81 females developed a complication due to device dislodgement, and one male aged six years (0.7%) out of 59 developed a post-procedural complication; hence, the total failure rate was 1.4%. The perimembranous type had no complication, and the muscular type had two (14.3%) unsuccessful procedures. Conclusion This study has concluded an impressive percentage of VSD closure, showing no mortality and low morbidity, using a percutaneous approach with different duct occluders. As the type of device used is not correlated with device failure and failure rate, duct occluders will be financially helpful in the closure of VSD in indicated patients.

5.
Ann Pediatr Cardiol ; 16(1): 18-24, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37287846

RESUMO

Objectives: Aortic dilatation and regurgitation after surgical repair of tetralogy of Fallot (TOF) is known, and beside other factors, mainly addressed to an intrinsic aortopathy. In 2011, we reported the influence of realingement of the left ventricular outflow tract (LVOT) by (partial) direct closure of the ventricular septal defect (VSD) in TOF on aortic structures and function. We now evaluated the further follow-up of this cohort and compared the results to a matched group of TOF patients with classical VSD patch closure. Patients and Methods: Forty patients with TOF treated between 2003 and 2008 are included in the study, with 20 patients each in the VSD (a) (partial) direct closure and (b) patch closure group. Follow-up time after surgery was 12.3 years (11.3-13.0). Results: Patient characteristics, echocardiographic measurements, and surgical and intensive care unit parameters were not significantly different between both groups. After surgery and during long-term follow-up, realignement of the LVOT, shown by the angle between the interventricular septum and the anterior aortic annulus in long axis view in echocardiography, was lower in Group A (34 vs. 45°, P < 0.0001). No differences in LVOT or aortic annulus size, aortic regurgitation, or dilation of the ascending aorta and right ventricular outflow tract gradients were found. Transient rhythm disturbances were found in 3 patients in each group, with only one persistent complete atrioventricular block in Group B. Conclusion: (Partial) direct closure of the VSD in TOF leads to a better realignement of the LVOT and showed comparable short- and long-term results without higher risk for rhythm disturbances during follow-up.

6.
Cardiovasc Revasc Med ; 53S: S153-S155, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36031539

RESUMO

Jatrogenic communication between left ventricle and right atrium, known as Gerbode type ventricular septal defect (GVSD) may be observed after different surgical interventions. We present a case of iatrogenic GVSD following complex cardiac surgery including septal myectomy combined with mitral and aortic valve replacement, which was successfully closed percutanously by Occlutech septal occluder.


Assuntos
Comunicação Interventricular , Próteses Valvulares Cardíacas , Dispositivo para Oclusão Septal , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Cateterismo Cardíaco/efeitos adversos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/etiologia , Comunicação Interventricular/cirurgia , Doença Iatrogênica , Resultado do Tratamento
7.
Heart Views ; 23(2): 93-99, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36213425

RESUMO

Background: The successful management of ventricular septal defect (VSD) has been possible through the development of advanced techniques. In this regard, percutaneous VSD closure by employing different types of occluders as an alternative for surgery can help to achieve the most desirable postprocedural consequences. However, the studies reported contradictory results on the use of different brands of VSD occluders. Herein, we performed a systematic review and meta-analysis of published studies to assess pooled long-term success rate and potential complications of using the Nit-Occlud Lê VSD coil for VSD closure. Materials and Methods: Two reviewers began to deeply search the various databases for all eligible studies in accordance with the considered keywords. The inclusion criterion for retrieving the studies was to describe the mid-term or long-term consequences of VSD closing by the Nit-Occlud Lê VSD coil device. In the final, eight articles were eligible for the analysis. The follow-up time of the studies ranged from 6 months to 5 years. Results: The success rate of the procedure ranged from 87.0% to 100% considering the weight of each study, the pooled success rate of VSDs closure by Nit-Occlud Lê VSD coil device was 93.1% (95% confidence interval [CI]: 89.9% to 95.5%). The pooled prevalence of postprocedural residual shunt was estimated to be 9.6% (95%CI: 6.8% to 13.4%). The corrected pooled prevalence of trivial mild aortic regurgitation (AR) was 2.9% (95%CI: 1.5% to 5.4%); however, moderate-to-severe AR and complete heart block or right bundle branch block were shown to be rare. Conclusion: VSD closure using a Nit-Occlud Lê VSD coil device can lead to a high success rate with low rates of residual shunt, cardiac conductive or vascular disturbances.

8.
Sudan J Paediatr ; 22(2): 172-178, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36875944

RESUMO

The objective of this study was to review the outcome of patients who underwent transcatheter closure of ventricular septal defect (VSD) using Nit-Occlud® Leˆ VSD-Coil.A retrospective study was carried out at King Abdulaziz Cardiac Center on all paediatric patients who underwent interventional VSD closure, during the period from 2011 and 2016. Data were collected, including demographic information, cardiac diagnosis, pre-operative diagnosis, intra-operative findings and postoperative events. Out of 46 patients, who were evaluated for VSD device closure, 17 of them were excluded; 24 patients out of 29 had successful closure of VSD using Nit-Occlud Leˆ VSD-Coil (success rate of 83%), and five cases were referred to surgery. The age group was from 2 years up to 18 years. Almost 90% of VSD was the perimembranous (PM) type (26 patients) and 3 patients (10%) with muscular VSD. Ten of the 26 PM VSDs had TV accessory tissue partially covering the VSD defects. The hemodynamic assessment showed pulmonary blood flow to systemic blood flow ratio (Qp:Qs) > 1.5 in almost all the patients who underwent defect closure. Immediate closure of the defect was achieved in 11/24 patients (45%). In five additional patients, there was a tiny residual and eight with a small residual. With 6 months of follow-up, only six patients remained with tiny residual VSD defects.The Nit-Occlud® Leˆ VSD-Coil device has minimal effects on the aortic and tricuspid valves, and there was no permanent atrioventricular block, especially in patients with PM VSDs. Patients with a residual shunt should be followed, especially for haemolysis.

9.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-904720

RESUMO

@#Objective    To evaluate the mid-term safety, efficacy and feasibility of perventricular device closure for subarterial ventricular septal defect. Methods    Clinical data of 97 patients diagnosed with subarterial ventricular septal defect through echocardiography in West China Hospital from September 2013 to December 2015 were retrospectively analyzed. There were 66 males and 31 females aged 3 (1.8, 5.9) years. All the patients underwent perventricular device closure under the guidance of transesophageal echocardiography using eccentric occlusion device. Possible complications such as residual shunt, valvular regurgitation, atrioventricular conduction block and arrhythmias were recorded during the 1-year, 3-year and 5-year follow-up. Results    All the patients received perventricular device closure successfully except that 1 patient underwent open surgical repair under cardiopulmonary bypass 3 months later because of the migration of device. So the rate of complete closure was 99.0%. No residual shunt, moderate or severe valvular regurgitation, atrioventricular conduction block or arrhythmias were observed 5 years later. Conclusion    Treating subarterial ventricular septal defect through perventricular device closure exhibits remarkable mid-term efficacy, safety and feasibility with high success rate.

10.
Ann Pediatr Cardiol ; 9(3): 229-35, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27625520

RESUMO

BACKGROUND: Conventional methods of closure of ventricular septal defects involve placement of sutures 4-5 mm from the posterior inferior margin. This study compares the conventional method with an alternative technique wherein sutures are placed along the edge of the defect thereby "excluding" the conduction system and the tensor apparatus of the tricuspid valve from the suture line. MATERIALS AND METHODS: Between January 2013 and January 2016, 409 consecutive patients were retrospectively reviewed and divided into two matched groups. Group A (n = 174) underwent closure using the alternative technique and Group B (n = 235) with the conventional technique. Patients with isolated ventricular septal defects (VSDs) (n = 136) were separately analyzed as were infants within this subset. RESULTS: Immediate postoperative results were similar with no statistically significant differences in either group in terms of incidence of residual defects or postoperative tricuspid regurgitation. There was however a significantly increased incidence of post operative complete heart block (CHB) among patients in the conventional group (P = 0.02). Incidence of temporary heart block that reverted to sinus rhythm was also more in the conventional method group (Group B) (P = 0.03) as was right bundle branch block (P ≤ 0.05) in all the subsets of patients analyzed. CONCLUSION: Surgical closure of VSDs can be accomplished by placing sutures along the margins or away with comparable results. The incidence of CHB, however, seems to be less when the "excluding" technique is employed.

11.
Ann Pediatr Cardiol ; 7(2): 135-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24987261

RESUMO

Pseudoaneurysm of ascending aorta after cardiac surgery is rare in children. We report a case of successful surgical exclusion of ascending aortic pseudoaneurysm in a 15-year-old boy. The neck of the aneurysm was in close proximity to the right coronary artery (RCA).

13.
Exp Clin Cardiol ; 18(1): e50-4, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24294051

RESUMO

The ductus arteriosus originates from the persistence of the distal portion of the left sixth aortic arch. It connects the descending aorta (immediately distal to the left subclavian artery) to the roof of the main pulmonary artery, near the origin of the left pulmonary artery. Persistence of the duct beyond 48 h after birth is abnormal and results in patent ductus arteriosus (PDA). PDA is rare in adults because it is usually discovered and treated in childhood. Mechanical closure remains the definitive therapy because the patency of ductus arteriosus may lead to multiple complications, depending on the size and flow through the ductus. PDA closure is indicated in patients with symptoms and evidence of left heart enlargement, and in patients with elevated pulmonary pressures when reversal is possible. Transcatheter closure is the preferred technique in adults because it avoids sternotomy, reduces the length of hospital stay and is associated with fewer complications compared with surgery. First demonstrated in 1967, both the technique and the occluder devices used have since evolved. However, designing an ideal PDA occluder has been a challenge due to the variability in size, shape and orientation of PDAs. The present article describes a case involving a 35-year-old woman who presented to the Center for Advanced Heart Failure (Houston, USA) with congestive heart failure due to a large PDA, which was successfully occluded using an Amplatzer (St Jude Medical, USA) muscular ventricular septal defect closure device. The wider waist and dual-retention discs of these ventricular septal defect closure devices may be important factors to consider in the future development of devices for the occlusion of large PDAs.

14.
Ann Pediatr Cardiol ; 6(2): 176-8, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24688240

RESUMO

We report a successful perventricular closure of an apical muscular ventricular septal defect (mVSD) by a modified technique. An eight-month-old infant, weighing 6.5 kilograms, presented with refractory heart failure. The transthoracic echocardiogram showed multiple apical mVSDs with the largest one measuring 10 mm. perventricular device closure using a 12 mm Amplatzer mVSD occluder was planned. The left ventricular disk was positioned approximating the interventricular septum; however, the right ventricular (RV) disk was deployed on the free wall of the RV due to an absent apical muscular septum and a small cavity at the apex. The RV disk of the device was covered using an autologous pericardium. His heart failure improved during follow-up.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...