Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 711.830
Filtrar
1.
Biomed Phys Eng Express ; 10(5)2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38959873

RESUMO

Objective. Recent innovative neurostimulators allow recording local field potentials (LFPs) while performing motor tasks monitored by wearable sensors. Inertial sensors can provide quantitative measures of motor impairment in people with subthalamic nucleus deep brain stimulation. To the best of our knowledge, there is no validated method to synchronize inertial sensors and neurostimulators without an additional device. This study aims to define a new synchronization method to analyze disease-related brain activity patterns during specific motor tasks and evaluate how LFPs are affected by stimulation and medication.Approach. Fourteen male subjects treated with subthalamic nucleus deep brain stimulation were recruited to perform motor tasks in four different medication and stimulation conditions. In each condition, a synchronization protocol was performed consisting of taps on the implanted neurostimulator, which produces artifacts in the LFPs that a nearby inertial sensor can simultaneously record.Main results. In 64% of the recruited subjects, induced artifacts were detected at least in one condition. Among those subjects, 83% of the recordings could be synchronized offline analyzing LFPs and wearables data. The remaining recordings were synchronized by video analysis.Significance. The proposed synchronization method does not require an external system (e.g., TENS electrodes) and can be easily integrated into clinical practice. The procedure is simple and can be carried out in a short time. A proper and simple synchronization will also be useful to analyze subthalamic neural activity in the presence of specific events (e.g., freezing of gait events) to identify predictive biomarkers.


Assuntos
Estimulação Encefálica Profunda , Núcleo Subtalâmico , Humanos , Estimulação Encefálica Profunda/métodos , Estimulação Encefálica Profunda/instrumentação , Masculino , Pessoa de Meia-Idade , Artefatos , Processamento de Sinais Assistido por Computador , Adulto , Dispositivos Eletrônicos Vestíveis , Doença de Parkinson/terapia , Doença de Parkinson/fisiopatologia , Encéfalo , Idoso
2.
J Refract Surg ; 40(7): e445-e452, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007818

RESUMO

PURPOSE: To evaluate the repeatability of automatic measurements of a new anterior segment optical coherence tomographer (ANTERION; Heidelberg Engineering) and their agreement with an anterior segment optical coherence tomography device combined with Placido disc corneal topography (MS-39; CSO) in patients affected by keratoconus. METHODS: Fifty-four consecutive patients were included. Three measurements were performed with the ANTERION and one with the MS-39. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Agreement was investigated with the 95% limits of agreement. The paired t-test and Wilcoxon matched-pairs test were performed to compare the measurements of the different devices. RESULTS: Repeatability of ANTERION measurements was high, with an ICC greater than 0.98 for all parameters. Many parameters revealed a CoV of less than 1% and a CoV within 5% was obtained for astigmatism measurements. The ANTERION measured a significantly higher corneal power and the MS-39 more negative posterior keratometric values. These differences were mirrored by a moderate agreement for mean simulated keratometry and poor agreement for total corneal power and posterior keratometry. CONCLUSIONS: The ANTERION revealed high repeatability of automatic measurements and good agreement with the MS-39 for many parameters in patients affected by keratoconus, but for most parameters the two instruments cannot be considered interchangeable. [J Refract Surg. 2024;40(7):e445-e452.].


Assuntos
Segmento Anterior do Olho , Topografia da Córnea , Ceratocone , Tomografia de Coerência Óptica , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Adulto , Topografia da Córnea/métodos , Masculino , Feminino , Segmento Anterior do Olho/diagnóstico por imagem , Adulto Jovem , Biometria/instrumentação , Biometria/métodos , Estudos Prospectivos , Córnea/patologia , Córnea/diagnóstico por imagem , Pessoa de Meia-Idade , Adolescente
3.
Neurosurg Rev ; 47(1): 330, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007950

RESUMO

Despite advancements in treatment modalities such as flow diverters, the optimal management of posterior communicating artery (PComA) aneurysms remains uncertain. While PComA aneurysms treated with the Pipeline Embolization Device (PED) has been reported, the characteristics and progression of incomplete occluded aneurysms remain unclear. Therefore, our study aims to investigate the occlusion status and recurrence rates of PComA aneurysms treated with PED. A retrospective review of consecutive PComA aneurysm patients treated with PED was conducted between January 2015 and December 2020. Only patients with radiological follow-up were included. PComA aneurysms were categorized into incomplete occlusion and complete occlusion group. The primary outcomes included the characteristics of incomplete occlusion at the follow-up angiography. Among 121 PComA aneurysms treated with PED at our institution, 80 aneurysms were eligible in our study. During the follow-up period, 19 (23.8%) aneurysms demonstrated incomplete occlusion. Notably, there were no instances of recurrence among the 80 followed-up cases. Baseline characteristics of patients and aneurysms were comparable between the groups with complete and incomplete occlusion. However, the incomplete occlusion group showed a lower rate of assisted coils embolization (21.2% vs. 55.7%, P = 0.017) and shorter median operative time (91.0 vs. 145.5 min, P = 0.039). Differences in functional outcomes, complications, and PComA occlusion status between the groups were not significant. Multivariate analysis revealed the use of coils was associated with lower odds of incomplete PComA aneurysm occlusion (OR 0.01, 95% CI 0.001-0.12; P = 0.001), while aneurysm size was associated with higher odds of incomplete occlusion (OR 1.25, 95% CI 1.10-1.46; P = 0.002). The treatment of PED for PComA aneurysm demonstrated favorable outcomes, with an acceptable rate of incomplete occlusion and no instances of recurrence observed. However, further research is needed to explore the optimal procedural strategy for large-sized PComA aneurysms.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Recidiva , Humanos , Aneurisma Intracraniano/terapia , Masculino , Embolização Terapêutica/métodos , Embolização Terapêutica/instrumentação , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Adulto , Angiografia Cerebral
4.
Methods Mol Biol ; 2805: 89-100, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39008175

RESUMO

Engineered heart tissues (EHTs) have been shown to be a valuable platform for disease investigation and therapeutic testing by increasing human induced pluripotent stem cell-derived cardiomyocyte (hiPSC-CM) maturity and better recreating the native cardiac environment. The protocol detailed in this chapter describes the generation of miniaturized EHTs (mEHTs) incorporating hiPSC-CMs and human stromal cells in a fibrin hydrogel. This platform utilizes an array of silicone posts designed to fit in a standard 96-well tissue culture plate. Stromal cells and hiPSC-CMs are cast in a fibrin matrix suspended between two silicone posts, forming an mEHT that produces synchronous muscle contractions. The platform presented here has the potential to be used for high throughput characterization and screening of disease phenotypes and novel therapeutics through measurements of the myocardial function, including contractile force and calcium handling, and its compatibility with immunostaining.


Assuntos
Células-Tronco Pluripotentes Induzidas , Miócitos Cardíacos , Engenharia Tecidual , Humanos , Engenharia Tecidual/métodos , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo , Células-Tronco Pluripotentes Induzidas/citologia , Células-Tronco Pluripotentes Induzidas/metabolismo , Hidrogéis/química , Diferenciação Celular , Fibrina/metabolismo , Células Cultivadas , Técnicas de Cultura de Células/métodos , Células Estromais/citologia , Técnicas de Cultura de Tecidos/métodos , Técnicas de Cultura de Tecidos/instrumentação
5.
Clin Cardiol ; 47(7): e24317, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38953595

RESUMO

INTRODUCTION: The DESyne novolimus-eluting coronary stent (NES) is a new-generation drug-eluting stent (DES) that is widely used, but clinical data are rarely reported for this stent. We compared the safety and effectiveness of the DESyne NES and the Orsiro bioresorbable polymer sirolimus-eluting stent (SES) in patients undergoing percutaneous coronary intervention (PCI). METHODS: This was a retrospective, single-center, observational study. Between July 2017 and December 2022, patients who presented with chronic or acute coronary syndrome undergoing PCI with DESyne NES or Orsiro SES were consecutively enrolled in the present study. The primary endpoint, major adverse cardiovascular event (MACE), was a composite of cardiovascular death, target-vessel myocardial infarction, or clinically driven target-lesion revascularization. RESULTS: A total of 776 patients (age 68.8 ± 12.2; 75.9% male) undergoing PCI were included. Overall, 231 patients with 313 lesions received NES and 545 patients with 846 lesions received SES. During a follow-up duration of 784 ± 522 days, the primary endpoint occurred in 10 patients (4.3%) in the NES group and in 36 patients (6.6%) in the SES group. After multivariate adjustment, the risk of MACE did not significantly differ between groups (NES vs. SES, hazard ratio 0.74, 95% CI, 0.35-1.55, p = 0.425). The event rate of individual components of the primary endpoint was comparable between the two groups. CONCLUSIONS: Favorable and similar clinical outcomes were observed in patients undergoing PCI with either NES or SES in a medium-term follow-up duration. Future studies with adequately powered clinical endpoints are required for further evaluation.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Desenho de Prótese , Sirolimo , Humanos , Masculino , Feminino , Sirolimo/administração & dosagem , Estudos Retrospectivos , Idoso , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/instrumentação , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Fatores de Tempo , Seguimentos , Síndrome Coronariana Aguda/terapia , Fatores de Risco , Pessoa de Meia-Idade , Angiografia Coronária , Macrolídeos
6.
BMJ Open Qual ; 13(3)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38955396

RESUMO

Ambulatory management of congestive heart failure (HF) continues to be a challenging clinical problem. Recent studies have focused on the role of HF clinics, nurse practitioners and disease management programmes to reduce HF readmissions. This pilot study is a pragmatic factorial study comparing a coach intervention, a SMARTPHONE REMINDER system intervention and BOTH interventions combined to Treatment as USUAL (TAU). We determined that both modalities were acceptable to patients prior to randomisation. Fifty-four patients were randomised to the four groups. The COACH group had no readmissions for HF 6 months after enrolment compared with 18% for the SMARTPHONE REMINDER Group, 8% for the BOTH intervention group and 13% for TAU. Medium-to-high medication adherence was maintained in all four groups although sodium consumption was lower at 3 months for the COACH and combined (BOTH) groups. This pilot study suggests a beneficial effect on rehospitalisation with the use of support measures including coaches and telephone reminders that needs confirmation in a larger trial.


Assuntos
Insuficiência Cardíaca , Sistemas de Alerta , Smartphone , Humanos , Insuficiência Cardíaca/terapia , Projetos Piloto , Masculino , Feminino , Sistemas de Alerta/estatística & dados numéricos , Sistemas de Alerta/instrumentação , Smartphone/estatística & dados numéricos , Idoso , Pessoa de Meia-Idade , Readmissão do Paciente/estatística & dados numéricos , Adesão à Medicação/estatística & dados numéricos
7.
Ghana Med J ; 58(1): 26-33, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38957281

RESUMO

Objectives: Patients requiring surgery for secondary peritonitis demonstrate a significantly increased risk for incisional surgical site infection. This study aimed to evaluate the efficacy of subcutaneous wound drain post-laparotomy for contaminated surgical wounds. Design: This was a prospective comparative hospital-based study. Setting: Patients who had surgery for secondary peritonitis in Irrua Specialist Teaching Hospital were studied. Participants: Fifty patients aged 16 years and above who presented with secondary peritonitis. Intervention: Patients who met the inclusion criteria were randomized into two equal groups. Group A had a suction drain placed in the subcutaneous space after laparotomy while Group B did not. Main outcome measures: Development of incisional surgical site infection, wound dehiscence, and duration of post-operative hospital stay. Results: The incidence of incisional surgical site infection was significantly less in Group A (20%) than in Group B (68%). There was no case of wound dehiscence in Group A as against 3 (12%) in Group B. The difference was not statistically significant. The mean duration of hospital stay was significantly less with subcutaneous suction drain (8.96+2.81 Vs 14.04+8.05; p = 0.005). Conclusion: Subcutaneous suction drainage is beneficial in abdominal wall closure in cases of peritonitis as it significantly reduces the incidence of incisional surgical site infection and the duration of postoperative hospital stay. The reduction in surgical wound dehiscence observed in this study was, however, not statistically significant. Funding: None declared.


Assuntos
Técnicas de Fechamento de Ferimentos Abdominais , Tempo de Internação , Peritonite , Deiscência da Ferida Operatória , Infecção da Ferida Cirúrgica , Humanos , Masculino , Feminino , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/epidemiologia , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto , Peritonite/etiologia , Deiscência da Ferida Operatória/epidemiologia , Deiscência da Ferida Operatória/prevenção & controle , Deiscência da Ferida Operatória/etiologia , Técnicas de Fechamento de Ferimentos Abdominais/instrumentação , Idoso , Sepse/etiologia , Sepse/epidemiologia , Drenagem/instrumentação , Laparotomia , Sucção/métodos , Adulto Jovem
9.
Nat Commun ; 15(1): 5635, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38965218

RESUMO

The wearable contact lens that continuously monitors intraocular pressure (IOP) facilitates prompt and early-state medical treatments of oculopathies such as glaucoma, postoperative myopia, etc. However, either taking drugs for pre-treatment or delaying the treatment process in the absence of a neural feedback component cannot realize accurate diagnosis or effective treatment. Herein, a neuroprosthetic contact lens enabled sensorimotor system is reported, which consists of a smart contact lens with Ti3C2Tx Wheatstone bridge structured IOP strain sensor, a Ti3C2Tx temperature sensor and an IOP point-of-care monitoring/display system. The point-of-care IOP monitoring and warning can be realized due to the high sensitivity of 12.52 mV mmHg-1 of the neuroprosthetic contact lens. In vivo experiments on rabbit eyes demonstrate the excellent wearability and biocompatibility of the neuroprosthetic contact lens. Further experiments on a living rate in vitro successfully mimic the biological sensorimotor loop. The leg twitching (larger or smaller angles) of the living rat was demonstrated under the command of motor cortex controlled by somatosensory cortex when the IOP is away from the normal range (higher or lower).


Assuntos
Lentes de Contato , Pressão Intraocular , Sistemas Automatizados de Assistência Junto ao Leito , Animais , Pressão Intraocular/fisiologia , Coelhos , Ratos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Dispositivos Eletrônicos Vestíveis , Próteses Neurais , Humanos , Retroalimentação Sensorial/fisiologia
10.
Sci Rep ; 14(1): 15389, 2024 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965256

RESUMO

The objective was to explore the efficacy of single-port laparoscopic percutaneous extraperitoneal closure using double-modified hernia needles with hydrodissection (SLPEC group) and two-port laparoscopic percutaneous extraperitoneal closure (TLPEC group) for the treatment of giant indirect inguinal hernias in children. We performed a retrospective review of all children with giant indirect inguinal hernias (inner ring orifice diameter ≥ 1.5 cm) who underwent laparoscopic high ligation of the hernia sac at FuJian Children's Hospital from January 2019 to December 2021. We collected data from the medical records of all the children and analysed their clinical characteristics and operation-related and follow-up information. Overall, this study included a cohort of 219 patients with isolated giant inguinal hernias who had complete clinical data and who had undergone laparoscopic high ligation of the hernia sac at our centre. All procedures were successfully performed for the 106 patients who underwent SLPEC and for the 113 patients who underwent TLPEC at our centre. There were no statistically significant differences in patient age, sex, body weight, follow-up time or the side of inguinal hernia between the SLPEC group and the TLPEC group (P = 0.123, 0.613, 0.121, 0.076 and 0.081, respectively). However, there were significant differences in the bleeding volume, visual analogue scale (VAS) score, and postoperative activity time between the two groups (P ≤ 0.001). The operation times in the TLPEC group were significantly longer than those in the SLPEC group (P = 0.048), but there were no significant differences in hospital length of stay or hospitalization costs between the two groups (P = 0.244 and 0.073, respectively). Incision scars were found in 2 patients in the SLPEC group and 9 patients in the TLPEC group, and there was a significant difference between the two groups (P = 0.04). However, the incidence of ipsilateral hernia recurrence, surgical site infection, suture-knot reactions and chronic inguinodynia did not significantly differ between the two groups (P = 0.332, 0.301, 0.332 and 0.599, respectively). Postoperative hydrocele occurred in only 1 male child in the SLPEC group and in no male children in the TLPEC group, and there was no difference between the two groups (P = 0.310). In this study, there were no cases of testicular atrophy or iatrogenic ascent of the testis. Compared with the TLPEC group, the SLPEC group had the advantages of a concealed incision, light scarring, minimal invasiveness, a reduced operation time, minimal bleeding, mild pain and rapid recovery. In conclusion, SLPEC using double-modified hernia needles with hydrodissection and high ligation of the hernia sac is a safe, effective and minimally invasive surgery. The cosmetic results are impressive, and the follow-up results are promising.


Assuntos
Hérnia Inguinal , Herniorrafia , Laparoscopia , Humanos , Hérnia Inguinal/cirurgia , Masculino , Laparoscopia/métodos , Feminino , Estudos Retrospectivos , Pré-Escolar , Criança , Herniorrafia/métodos , Herniorrafia/instrumentação , Agulhas , Lactente , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
11.
Sci Rep ; 14(1): 15295, 2024 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961171

RESUMO

Palatal injections are considered to be one of the most painful dental procedures. As a result, it was important to find alternatives to this painful injection to improve children's cooperation. The dental literature mentioned using EMLA cream as a possible alternative to conventional injections, but its anesthetic effect was debated. Therefore, it was valuable to research the impact of microneedle patches to enhance the effectiveness of this cream. The purpose of this randomized controlled clinical trial was to compare the effectiveness of different methods of anesthesia and pain levels in children aged 7-11 years. The study compared the use of EMLA cream, EMLA with microneedles, and conventional palatal injections. A total of 90 children were randomly assigned to three groups: Group 1 received conventional palatal anesthesia (control), Group 2 received EMLA cream only, and Group 3 received EMLA with microneedles. Pain levels were assessed using the FLACC and Wong-Baker scales at three different time points: T1(during anesthesia), T2(on palatal probing), and T3(during extraction). The FLACC scale revealed a significant difference in pain between groups only at T1 (P value = 0.000). It was found that the conventional palatal injection group had a higher pain level than the EMLA cream-only group and the group using microneedle patches with EMLA cream (P value = 0.000). However, the other groups did not show significant differences in pain levels during the anesthesia (P value = 1.00). Similarly, the Wong-Baker scale also demonstrated a statistically significant difference in pain between groups only at T1 (P value = 0.000). It was found that the conventional palatal injection group had a higher pain level than the EMLA cream-only group and the group using microneedle patches with EMLA cream (P value = 0.000). However, the other groups did not show significant differences in pain levels during the anesthesia (P value = 0.091). The study concludes that both EMLA cream alone and EMLA with microneedles can be used as an alternative to conventional palatal anesthesia for children.


Assuntos
Anestésicos Locais , Combinação Lidocaína e Prilocaína , Agulhas , Palato , Humanos , Criança , Combinação Lidocaína e Prilocaína/administração & dosagem , Feminino , Masculino , Anestésicos Locais/administração & dosagem , Medição da Dor , Anestesia Dentária/métodos , Anestesia Dentária/instrumentação , Lidocaína/administração & dosagem
12.
Methods Mol Biol ; 2827: 35-50, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38985261

RESUMO

Temporary immersion systems (TIS) have been widely recognized as a promising technology for micropropagation of various plant species. The TIS provides a suitable environment for culture and allows intermittent contact of the explant with the culture medium at different immersion frequencies and aeration of the culture in each cycle. The frequency or immersion is one of the most critical parameters for the efficiency of these systems. The design, media volume, and container capacity substantially improve cultivation efficiency. Different TIS have been developed and successfully applied to micropropagation in various in vitro systems, such as sprout proliferation, microcuttings, and somatic embryos. TIS increases multiplication and conversion rates to plants and a better response during the ex vitro acclimatization phase. This article covers the use of different immersion systems and their applications in plant biotechnology, particularly in plant tissue culture, as well as its use in the massive propagation of plants of agroeconomic interest.


Assuntos
Aclimatação , Desenvolvimento Vegetal , Meios de Cultura/química , Técnicas de Cultura de Tecidos/métodos , Técnicas de Cultura de Tecidos/instrumentação , Brotos de Planta/crescimento & desenvolvimento , Brotos de Planta/fisiologia , Plantas , Imersão , Técnicas de Embriogênese Somática de Plantas/métodos
13.
BMC Anesthesiol ; 24(1): 229, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38987667

RESUMO

BACKGROUND: This study evaluated the effect of head rotation on the first-attempt success rate of i-gel insertion, aiming to alleviate the effect of gravity on the tongue and reduce resistance between the device and the tongue. METHODS: Adult surgical patients were randomized to standard and head rotation technique groups. In the head rotation technique group, patients' heads were maximally rotated to the left before i-gel insertion. The primary endpoint was the first-attempt success rate. Secondary endpoints included the success rate within two attempts (using the allocated technique), time required for successful i-gel placement within two attempts, and success rate at the third attempt (using the opposite technique). RESULTS: Among 158 patients, the head rotation technique group showed a significantly higher first-attempt success rate (60/80, 75.0%) compared to the standard technique group (45/78, 57.7%; P = 0.021). The success rate within two attempts was similar between the groups (95.0% vs. 91.0%, P = 0.326). The time required for successful i-gel placement was significantly shorter in the head rotation technique (mean [SD], 13.4 [3.7] s vs. 16.3 [7.8] s; P = 0.030). When the head rotation technique failed, the standard technique also failed in all cases (n = 4), whereas the head rotation technique succeeded in five out of the seven patients where the standard technique failed. CONCLUSIONS: The head rotation technique significantly improved the first-attempt success rate and reduced the time required for successful i-gel insertion. It was effective when the standard technique failed. The head rotation technique may be an effective primary or alternative method for i-gel insertion. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov (NCT05201339).


Assuntos
Cabeça , Humanos , Masculino , Feminino , Rotação , Pessoa de Meia-Idade , Adulto , Intubação Intratraqueal/métodos , Intubação Intratraqueal/instrumentação , Idoso , Posicionamento do Paciente/métodos , Língua
14.
BMC Musculoskelet Disord ; 25(1): 531, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38987691

RESUMO

BACKGROUND: The treatment of the displaced proximal humerus fractures (PHF) still facing a lot of unsolved problems. The aim of this study was to evaluate the clinical effect of MultiLoc nails for the treatment of PHF and present outcomes of patients with different Neer's classification and reduction quality. METHODS: Adult patients with PHFs were recruited and treated with MultiLoc nail. Intraoperative data, radiographic and functional outcomes, as well as occurrence of postoperative complications were assessed. RESULTS: 48 patients met inclusion and exclusion criteria and were included in this study. The DASH Score were 32.2 ± 3.1 points at 12 months, and 37.3 ± 2.5 points at the final follow-up. The mean ASES score at 12 months and final follow-up were 74.4 ± 6.2 and 78.8 ± 5.1, respectively. The mean CM Score in all 48 patients reached 68 ± 6.4 points at the final follow-up, relative side related CM Score 75.2 ± 7.7% of contralateral extremity. The incidence rate of complications was 20.8%. Patients with fracture mal-union, adhesive capsulitis were observed but no secondary surgeries were performed. There was no significantly difference of DASH Score 12 months after surgery and at the last follow-up among patients with different Neer's classification or reduction quality. However, functional outcomes such as ASES score and CM score were significantly influenced by severity of fracture and the quality of fracture reduction. CONCLUSIONS: Our study demonstrated that MultiLoc nails is well suited for proximal humeral fractures, with satisfactory health status recovery, good radiographic results, positive clinical outcomes and low rates of complications. The treatment for four part PHF still faces great challenges. Accurate fracture reduction was an important factor for good functional result.


Assuntos
Pinos Ortopédicos , Fixação Intramedular de Fraturas , Complicações Pós-Operatórias , Fraturas do Ombro , Humanos , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/efeitos adversos , Idoso , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Adulto , Nível de Saúde , Seguimentos , Radiografia , Estudos Retrospectivos
15.
Crit Care ; 28(1): 230, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38987802

RESUMO

BACKGROUND: Impaired microcirculation is a cornerstone of sepsis development and leads to reduced tissue oxygenation, influenced by fluid and catecholamine administration during treatment. Hyperspectral imaging (HSI) is a non-invasive bedside technology for visualizing physicochemical tissue characteristics. Machine learning (ML) for skin HSI might offer an automated approach for bedside microcirculation assessment, providing an individualized tissue fingerprint of critically ill patients in intensive care. The study aimed to determine if machine learning could be utilized to automatically identify regions of interest (ROIs) in the hand, thereby distinguishing between healthy individuals and critically ill patients with sepsis using HSI. METHODS: HSI raw data from 75 critically ill sepsis patients and from 30 healthy controls were recorded using TIVITA® Tissue System and analyzed using an automated ML approach. Additionally, patients were divided into two groups based on their SOFA scores for further subanalysis: less severely ill (SOFA ≤ 5) and severely ill (SOFA > 5). The analysis of the HSI raw data was fully-automated using MediaPipe for ROI detection (palm and fingertips) and feature extraction. HSI Features were statistically analyzed to highlight relevant wavelength combinations using Mann-Whitney-U test and Benjamini, Krieger, and Yekutieli (BKY) correction. In addition, Random Forest models were trained using bootstrapping, and feature importances were determined to gain insights regarding the wavelength importance for a model decision. RESULTS: An automated pipeline for generating ROIs and HSI feature extraction was successfully established. HSI raw data analysis accurately distinguished healthy controls from sepsis patients. Wavelengths at the fingertips differed in the ranges of 575-695 nm and 840-1000 nm. For the palm, significant differences were observed in the range of 925-1000 nm. Feature importance plots indicated relevant information in the same wavelength ranges. Combining palm and fingertip analysis provided the highest reliability, with an AUC of 0.92 to distinguish between sepsis patients and healthy controls. CONCLUSION: Based on this proof of concept, the integration of automated and standardized ROIs along with automated skin HSI analyzes, was able to differentiate between healthy individuals and patients with sepsis. This approach offers a reliable and objective assessment of skin microcirculation, facilitating the rapid identification of critically ill patients.


Assuntos
Estado Terminal , Imageamento Hiperespectral , Aprendizado de Máquina , Microcirculação , Humanos , Aprendizado de Máquina/normas , Masculino , Feminino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Idoso , Imageamento Hiperespectral/métodos , Sepse/fisiopatologia , Sepse/diagnóstico , Adulto , Estudo de Prova de Conceito , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação
16.
Langenbecks Arch Surg ; 409(1): 217, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39017727

RESUMO

BACKGROUND: We conducted a systematic review and meta-analysis to evaluate the role of High Energy Devices (HEDs) versus conventional clamp and tie technique in thyroidectomy. This work is endorsed by the Italian Society of Surgical Endoscopy (Italian Society of Endoscopic Surgery and new technologies-SICE) in the broader project on the evaluation of the role of HEDs in different surgical settings with the full health technology assessment report. MEHODS: Inclusion criteria were adult patients (≥ 18 years old) undergoing Thyroidectomy/Parathyroidectomy conducted with High Energy Devices (as ultrasonic (US), radiofrequency (RF), and hybrid energy (H-US/RF)) in the setting of thyroid surgery (both partial and total) for benign and malign diseases. However, some variability was found in included studies and described in the text. This systematic review and meta-analysis were performed according to the Cochrane handbook for systematic reviews, and the recommendations of the 2020 updated Preferred Reporting Items for Systematic reviews and Meta-analyses (PRISMA) guidelines were pursuit. Selection of abstracts was performed in Ryyan system by 2 independent reviewers, and doubts were solved by another independent reviewer. At the end of literature research, Randomized controlled trials and observational studies were included. Risk of Bias was assessed with ROB2 for RCTs, and New Castle Ottawa Scale for Observational studies. RESULTS: The literature search yielded 47 studies, including 29 RCTs and 18 observational studies. Meta-analysis was performed for 29 randomized clinical trials. Outcomes included in the comparison between High Energy Devise and conventional technique groups were operative time, operative blood loss, overall post-operative drainage volume, length of stay, complications, and costs. HED significantly reduced operative time (28 studies, 3097patients; MD -128.8; 95% CI -34.4 to -23.20; I2 = 96%, p < 0.00001, Random-effect), intra-operative blood loss (13 studies, 642 vs 519 patients; SMD -0.82; 95% CI -1.33 to -0.32; I2 = 93%, p < 0.00001, Random-effect), LOS (22 studies, 2808 vs 2789 patients; MD -0.38, 95% CI -0.59 to -0.17; I2 = 98%, p < 0.00001 Random-effect), and healthcare costs (8 studies, 1138 vs 1129 patients, SMD 1.05; 95% CI -0.06 to 2.16; I2 = 99%, p < 0.00001 Random-effect). The rate of overall intraoperative complications was significantly different between both groups (25 studies, 2804 vs 2775 patients; RR 0.88, 95% CI 0.80 to 0.97; I2 = 38%, p = 0.03 Random-effect), but the sensitivity analysis did not find a statistically significant difference (6 studies, 605 vs 594 patients, RR; 95% CI to; I2 = 0%, p = 0.50, Random-effect). There was no difference in the subgroup analysis for the occurrence of transient and permanent RLN palsy, nor hematoma formation and hypocalcaemia. DISCUSSION: Though findings of our systematic review and metanalysis are limited by heterogeneous data, surgeons, hospital managers, and policymakers should note that the use of High Energy Devices compared to conventional clamp and tie technique have reduced operative times, intra-operative blood loss, length of stay, and hospital costs in patients underwent to tyroid surgery. Future work must explore issues of equity to mitigate barriers to patient access to safe thyroid surgical care and define better this initial results.


Assuntos
Tireoidectomia , Humanos , Tireoidectomia/métodos , Tireoidectomia/efeitos adversos , Tireoidectomia/instrumentação , Doenças da Glândula Tireoide/cirurgia , Paratireoidectomia/métodos
17.
Artigo em Inglês | MEDLINE | ID: mdl-39017782

RESUMO

This chapter is intended to provide a brief overview of the optics of surgical microscopes and rigid endoscopes, with the aim of providing the reader with the principles dictating the nature of surgical visualization when either of the visual control systems is used. It is not by any means geared toward elaborating on the detailed optical physics of these systems, which is beyond the scope and objective of this chapter.


Assuntos
Microscopia , Humanos , Microscopia/instrumentação , Microscopia/métodos , Procedimentos Neurocirúrgicos/instrumentação , Procedimentos Neurocirúrgicos/métodos , Microcirurgia/instrumentação , Microcirurgia/métodos , Endoscópios , Neuroendoscópios
18.
Adv Tech Stand Neurosurg ; 52: 73-90, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39017787

RESUMO

BACKGROUND: Fully endoscopic or endoscope-controlled approaches are essentially keyhole approaches in which rigid endoscopes are the sole visualization tools used during the whole procedure. At the early attempts of endoscope-assisted cranial surgery, it was noted that rigid endoscopes enabled overcoming the problem of suboptimal visualization when small exposures are used. The technical specifications and design of the currently available rigid endoscopes are associated with a group of unique features that define the endoscopic view and lay the basis for its superiority over the microscopic view during brain surgery. Fully endoscopic resection of intraparenchymal brain tumors is a minimally invasive approach that is not routinely practiced by neurosurgeons, with a few major series published so far. Unfamiliarity with the technique, steep learning curve, and concerns about inadequate exposure and decreased visibility may explain this fact. The majority of the purely endoscopic resections for intraparenchymal brain lesions are performed nowadays through tubular retractor systems. In very limited instances, however, the fully endoscopic technique is performed without tubular retractors. In this chapter, we elaborate on the surgical technique and nuances of the fully endoscopic nontubular retractor approach for intraaxial tumors. METHODS: From a prospective database of endoscopic procedures maintained by the senior author, clinical data, imaging studies, and operative charts and videos of cases undergoing fully endoscopic excision for intraaxial brain tumors were retrieved and analyzed. The pertinent literature was also reviewed. RESULTS: The surgical technique of the fully endoscopic nontubular retractor approach for intraaxial tumors was formulated. CONCLUSION: The endoscopic technique has many advantages over the conventional procedures. In our hands, the technique has proven to be feasible, efficient, and minimally invasive with excellent results.


Assuntos
Neoplasias Encefálicas , Neuroendoscopia , Humanos , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/patologia , Neuroendoscopia/métodos , Neuroendoscopia/instrumentação
19.
Adv Tech Stand Neurosurg ; 52: 63-72, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39017786

RESUMO

OBJECTIVE: Transcortical approaches using a spatula-based retraction system have traditionally been used for the microsurgical resection of deep-seated intraventricular and parenchymal brain tumors. Recently, transparent cylindrical or tubular retractors have been developed to provide a stable corridor to access deeper brain lesions and perform bimanual microsurgical resection. The flexible endoports minimize brain retraction injury during surgery and, along with the superior vision of endoscopes, offer several advantages over standard microsurgery. In this chapter, we describe the surgical technique of the endoport-guided endoscopic excision of deep-seated intraaxial brain tumors. METHODS: The endoscopic endoport technique that we use at our institution for the surgical management of intraventricular and intraparenchymal brain tumors has been described in detail with illustrative cases. RESULTS: Results from the literature review of intraventricular and intraparenchymal port surgery were analyzed, and the feasibility and safety of this technique were discussed. Surgical complication avoidance and management were highlighted. The port technique offers numerous potential advantages, including (1) reducing focal brain injury by distributing retraction forces homogenously, (2) minimizing white matter disruption and the risk of fascicle injury during cannulation, (3) ensuring the stability of the surgical corridor during the procedure, (4) preventing inadvertent expansion of the corticectomy and white fiber tract dissection throughout surgery, and (5) protecting the surrounding tissues against iatrogenic injuries caused by instrument entry and reentry. CONCLUSION: The endoport-assisted endoscopic technique is safe and offers an effective alternative option for the resection of intraventricular and intraparenchymal lesions.


Assuntos
Neoplasias Encefálicas , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Encefálicas/cirurgia , Neuroendoscopia/métodos , Neuroendoscopia/instrumentação , Procedimentos Neurocirúrgicos/métodos
20.
Zhonghua Xin Xue Guan Bing Za Zhi ; 52(7): 784-790, 2024 Jul 24.
Artigo em Chinês | MEDLINE | ID: mdl-39019827

RESUMO

Objective: To investigate the value of implantable cardiac monitor (ICM) in the diagnosis and treatment of patients over 60 years old with unexplained syncope. Methods: This was a multi-center, prospective cohort study. Between June 2018 and April 2021, patients over the age of 60 with unexplained syncope at Beijing Hospital, Fuwai Hospital, Beijing Anzhen Hospital and Puren Hospital were enrolled. Patients were divided into 2 groups based on their decision to receive ICM implantation (implantation group and conventional follow-up group). The endpoint was the recurrence of syncope and cardiogenic syncope as determined by positive cardiac arrhythmia events recorded at the ICM or diagnosed during routine follow-up. Kaplan-Meier survival analysis was used to compare the differences of cumulative diagnostic rate between the 2 groups. A multivariate Cox regression analysis was performed to determine independent predictors of diagnosis of cardiogenic syncope in patients with unexplained syncope. Results: A total of 198 patients with unexplained syncope, aged (72.9±8.25) years, were followed for 558.0 (296.0,877.0) d, including 98 males (49.5%). There were 100 (50.5%) patients in the implantation group and 98 (49.5%) in the conventional follow-up group. Compared with conventional follow-up group, patients in the implantation group were older, more likely to have comorbidities, had a higher proportion of first degree atrioventricular block indicated by baseline electrocardiogram, and had a lower body mass index (all P<0.05). During the follow-up period, positive cardiac arrhythmia events were recorded in 58 (58.0%) patients in the ICM group. The diagnosis rate (42.0% (42/100) vs. 4.1% (4/98), P<0.001) and the intervention rate (37.0% (37/100) vs. 2.0% (2/98), P<0.001) of cardiogenic syncope in the implantation group were higher than those in the conventional follow-up group (all P<0.001). Kaplan-Meier survival analysis showed that the cumulative diagnostic rate of cardiogenic syncope was significantly higher in the implantation group than in the traditional follow-up group (HR=11.66, 95%CI 6.49-20.98, log-rank P<0.001). Multivariate analysis indicated that ICM implantation, previous atrial fibrillation, diabetes mellitus or first degree atrioventricular block in baseline electrocardiogram were independent predictors for cardiogenic syncope (all P<0.05). Conclusions: ICM implantation improves the diagnosis and intervention rates in patients with unexplained syncope, and increases diagnostic efficiency in patients with unexplained syncope.


Assuntos
Síncope , Humanos , Idoso , Síncope/diagnóstico , Síncope/etiologia , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia/métodos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...