1.
Clin Chem Lab Med ; 58(5): 741-752, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-31926069

RESUMO

Background Classically, serum testosterone (T) and androstenedione (A4) have been the mainstay for the biochemical assessment of hyperandrogenism. However, recent evidence suggests 11ß-hydroxyandrostenedione (11OHA4) and 11-ketotestosterone (11KT) may also be important. Here, we describe the development of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for quantitation of total serum T, A4, 17-hydroxyprogesterone (17OHP), 11OHA4 and 11KT. In addition, we applied the method to assess pre-analytical stability. Methods An isotopically labelled internal standard was added to samples prior to supported liquid extraction (SLE). Extracts were analysed using LC-MS/MS to detect T/A4/17OHP/11OHA4 and 11KT along with their corresponding internal standards. Samples (n = 7) were collected from healthy volunteers (n = 14) and left incubated at 20 °C for up to 72 h. Tubes were retrieved at select time points, centrifuged, separated and frozen prior to analysis. Results The total run time was 4 min. For all analytes, intra- and inter-assay imprecision did not exceed 7.9% and 5.3%, respectively; matrix effects were negligible and mean recoveries ranged from 95.3 to 111.6%. The limits of quantitation (LOQs) were 0.25 nmol/L for T, A4 and 11OHA4, 0.50 nmol/L for 17OHP, and 0.24 nmol/L for 11KT. No significant change was observed in pre-centrifugation A4 or female T concentrations over 72 h. Significant increases (p < 0.01) in concentrations of 11KT, 17OHP, 11OHA4 and male T were observed after 2, 8, 12 and 24 h, respectively. Conclusions We developed a robust LC-MS/MS assay for the quantitation of total serum T/A4/17OHP/11OHA4 and 11KT. Applying the method to determine pre-analytical stability suggests samples requiring 11KT need separating from the cells within 2 h.


Assuntos
17-alfa-Hidroxiprogesterona/sangue , Androstenodiona/análogos & derivados , Androstenodiona/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Testosterona/análogos & derivados , Testosterona/sangue , 17-alfa-Hidroxiprogesterona/isolamento & purificação , 17-alfa-Hidroxiprogesterona/normas , Adulto , Androstenodiona/isolamento & purificação , Androstenodiona/normas , Cromatografia Líquida de Alta Pressão/normas , Feminino , Humanos , Marcação por Isótopo , Limite de Detecção , Extração Líquido-Líquido , Masculino , Fase Pré-Analítica , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/normas , Testosterona/isolamento & purificação , Testosterona/normas
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(19): 1565-72, 2011 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21514253

RESUMO

Adrenal steroid profiling, including 17α-OH progesterone (17OHP), 11-deoxycortisol (S), Δ4-androstenedione (Δ4-A) and cortisol (F) in blood spots by tandem mass spectrometry, is used for newborn screening to detect congenital adrenal hyperplasia (CAH). Pre-analytical sample processing is critical for assay specificity and accuracy; however, it is laborious and time-consuming. This study describes the development and validation of a new Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) method for the simultaneous quantification of five steroids: 17OHP, S, Δ4-A, F and cortisone (E) in blood spots from newborns. Whole blood was eluted from a 5.00 mm dried blood spot by an aqueous solution containing the deuterium-labeled internal standards d8-17OHP and d4-cortisol. The steroids extracted from blood spot into aqueous solution were subsequently purified via Extelut mini NT1 column using diethylether. The extracts were evaporated and quantified using LC-MS/MS. The detection limit was 0.25 ng/mL for 17OHP and S, 0.4 ng/mL for Δ4-A and 0.5 ng/mL for F and E. The limit of quantification was 0.5 ng/mL for 17OHP, S and Δ4-A and 1 ng/mL for F and E. Precision for 17OHP, S, Δ4-A at concentrations of 0.5, 2, and 8 ng/mL (n=5) in fortified steroid free serum samples was 1.3-3.5% (intra-assay CV) and 7-14.8% (inter-assay CV). Precision for F and E at concentrations of 5 and 20 ng/mL was 1.5-4.8% (intra-assay, CV%) and 6-15% (inter-assay, CV%). Accuracy was calculated at concentrations of 0.5, 2, and 8 ng/mL for 17OHP, S and Δ4-A and ranged from -0.3 to 0.2%, while for F and E it ranged from -3.2 to 0.2%. Relative recoveries at concentration 2 ng/mL and 8 ng/mL for 17OHP, S, Δ4-A and at 5 ng/mL and 20 ng/mL for F and E ranged from 55% to 80%. Reference intervals were estimated for all steroids in newborns (on day 3). The steroid profile assay herein described is sensitive, specific and accurate and involves a simple pre-analytical sample manipulation; it is therefore suitable for routine analysis and provides data for samples within normal range as well as those with elevated levels. For the first time to our knowledge, cortisone levels are reported in dried blood spots from newborns.


Assuntos
17-alfa-Hidroxiprogesterona/sangue , Androstenodiona/sangue , Cromatografia Líquida/métodos , Cortisona/sangue , Cortodoxona/sangue , Hidrocortisona/sangue , 17-alfa-Hidroxiprogesterona/isolamento & purificação , Androstenodiona/isolamento & purificação , Coleta de Amostras Sanguíneas , Cortisona/isolamento & purificação , Cortodoxona/isolamento & purificação , Feminino , Humanos , Hidrocortisona/isolamento & purificação , Recém-Nascido , Modelos Lineares , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem
3.
Clin Chim Acta ; 412(1-2): 186-9, 2011 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-20933513

RESUMO

BACKGROUND: Accurate measurement of 17-hydroxyprogesterone (17-OHP) concentrations is essential for the correct diagnosis and treatment management of children with congenital adrenal hyperplasia (CAH) due to 21-hydroxylase deficiency (21 OHD). METHODS: We analysed 102 serum samples from 15 children with known 21 OHD twice using two different 17-OHP assays. 17-OHP concentrations were measured by an in-house radioimmunoassay (RIA) after recovery-corrected extraction and chromatographic purification and by a commercially available RIA without extraction (Immunotech). RESULTS: The correlation coefficient for results of pairs of 17-OHP concentrations was 0.974. The median ratio (17-OHP concentration measured with the commercial assay/17-OHP concentration measured with the in-house assay) was 0.593 with a 95% confidence interval ranging from 0.258 to 1.370. The ratio was constant throughout the average 17-OHP concentrations ranging from 0.24 to 149.2 nmol/L, as well as throughout the age range from 0.3 to 16.4 years. CONCLUSIONS: Despite good overall correlation, absolute 17-OHP concentrations differed dramatically. This could lead to misclassification of patients suspected for 21 OHD on the basis of the hormonal profile and to a reduced quality during treatment monitoring of patients with 21 OHD with the risk of under- and overtreatment.


Assuntos
17-alfa-Hidroxiprogesterona/análise , Hiperplasia Suprarrenal Congênita/enzimologia , Hiperplasia Suprarrenal Congênita/terapia , Radioimunoensaio/métodos , Esteroide 21-Hidroxilase/metabolismo , 17-alfa-Hidroxiprogesterona/isolamento & purificação , Hiperplasia Suprarrenal Congênita/etiologia , Criança , Cromatografia , Humanos , Resultado do Tratamento
4.
Electrophoresis ; 27(20): 3988-98, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16983633

RESUMO

The purpose was to develop a stable biological membrane coating for CE useful for membrane interaction studies. The effect of cholesterol (chol) on the stability of dipalmitoylphosphatidylcholine (DPPC) and sphingomyelin (SM) coatings was studied. In addition, a fused-silica capillary for CE was coated with human red blood cell (RBC) ghost lipids. Liposomes prepared of DPPC/SM with and without chol or RBC ghost lipids were flushed through the capillary and the stability of the coating was measured electrophoretically. Similar mixtures of DPPC/SM with and without chol were further studied by differential scanning calorimetry. The presence of phosphatidylcholine as a basic component in the coating solution of DPPC/SM/chol was found to be essential to achieve a good and stable coating. The results also confirmed the stability of coatings obtained with solutions of DPPC with 0-30 mol% of chol and SM in different ratios, which more closely resemble natural membranes. Finally, the electrophoretic measurements revealed that a stable coating is formed when capillaries are coated with liposomes of RBC ghost lipids.


Assuntos
Eletroforese Capilar/métodos , Eritrócitos/química , Lipídeos de Membrana/química , Membranas Artificiais , 1,2-Dipalmitoilfosfatidilcolina/química , 17-alfa-Hidroxiprogesterona/isolamento & purificação , Aldosterona/isolamento & purificação , Androstenodiona/isolamento & purificação , Varredura Diferencial de Calorimetria , Colesterol/química , Eletro-Osmose , Eletroforese Capilar/instrumentação , Membrana Eritrocítica/química , Bicamadas Lipídicas/química , Progesterona , Testosterona/isolamento & purificação
5.
J Chromatogr A ; 1119(1-2): 163-9, 2006 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-16458905

RESUMO

1,2-Dioleyl-3-trymethylammoniumpropane (DOTAP) lipid vesicles were employed as coating precursors to obtain a semipermanent cationic lipid bilayer in silica capillary. The coating procedure was relatively fast and simple. Reliable results for the separation of four basic proteins (alpha-chymotrypsinogen A, ribonuclease A, cytochrome C, lysozyme) were obtained by using an acetate buffer under acidic conditions. The RSDs of the migration times were not higher than 0.5% run-to-run and about 1% day-to-day (3 days), while the RSDs of the peak areas were within 7% day-to-day (3 days). The day-to-day RSD of the EOF mobility of about 1%, confirmed that the DOTAP coating was stable for the separation of basic proteins, under acidic buffers. In addition to basic proteins the DOTAP coating was found suitable under acidic conditions for the repeatable separation of neutral steroids. The potential of DOTAP as a carrier in background electrolyte solution was studied.


Assuntos
Eletroforese Capilar/instrumentação , Bicamadas Lipídicas/química , Proteínas/isolamento & purificação , Esteroides/isolamento & purificação , 17-alfa-Hidroxiprogesterona/isolamento & purificação , Aldosterona/isolamento & purificação , Androstenodiona/isolamento & purificação , Cromatografia Líquida/instrumentação , Quimotripsinogênio/isolamento & purificação , Citocromos c/isolamento & purificação , Ácidos Graxos Monoinsaturados/química , Interações Hidrofóbicas e Hidrofílicas , Muramidase/isolamento & purificação , Progesterona/isolamento & purificação , Compostos de Amônio Quaternário/química , Reprodutibilidade dos Testes , Ribonuclease Pancreático/isolamento & purificação , Dióxido de Silício/química , Testosterona/isolamento & purificação
6.
Ecotoxicol Environ Saf ; 34(2): 165-73, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8812183

RESUMO

Testicular and ovarian fragments of Carassius auratus, taken during the reproductively active prespawning phase (June) of its annual reproductive cycle, were incubated with different concentrations (0 mg/ml, 0 ppm; 0.001 mg/ml, 1 ppm; 0.01 mg/ml, 10 ppm; and 0.02 mg/ml, 20 ppm) of gamma-hexachlorocyclohexane (gamma-HCH) in the presence of either exogenous precursor [3H]-17-hydroxyprogesterone ([3H]17-P) or carp hypophyseal homogenate. The free (unconjugated) and conjugated metabolites (glucuronides and sulfates) of [3H]-17-P [androstenedione (AD), androstenetrione, 17-hydroxyprogesterone, testosterone (T), 11-deoxycortisol (S), 17, 20alpha-dihydroxy-4-pregnen-3-one (17,20alphaP), 17, 20beta-dihydroxy-4-pregnen-3-one (17,20betaP), 7alpha-pregnanetetrols (7alpha-P), and other polar metabolites] were separated by thin-layer chromatography and high-performance liquid chromatography. The endogenous production of unconjugated (free) steroids T, 17,20betaP, S, and 11-ketotestosterone (11-KT) in response to gamma-HCH were measured by radioimmunoassay. Among the in vitro metabolism of [3H]-17-P, in males, free steroids of AD, T, 17,20alphaP, S, and polar-free steroids were increased with the decreased yield of 11-KT. Percentage yield of testosterone glucuronide (TG) was increased with highly significant decreased yields of polar glucuronide steroids. The sulfate steroids of 17, 20alphaP, 17,20betaP, S, and 11-KT remain unchanged. In females, the decreased percentage of yield of AD and S and elevated T were noticed. The yield of TG was increased with decreased yield of 7alpha-P glucuronides. The percentage yield of AD sulfate and sulfate steroids of 17,20alphaP, 17,20betaP, and S were noted to be increased, but the yield for S sulfate was very high. Endogenous production of T was increased in both sexes in the presence of gamma-HCH, but 11-KT in male and S in female were depressed. 17, 20betaP was stimulated at some concentrations in both sexes but levels were very low. Results indicate that gamma-HCH in vitro perturbed the steroid biosynthesis during this phase thereby affecting reproductive physiology.


Assuntos
Carpa Dourada/metabolismo , Hormônios Esteroides Gonadais/metabolismo , Hexaclorocicloexano/toxicidade , Reprodução/efeitos dos fármacos , Testosterona/análogos & derivados , 17-alfa-Hidroxiprogesterona/isolamento & purificação , 17-alfa-Hidroxiprogesterona/metabolismo , Animais , Cromatografia Líquida de Alta Pressão , Cromatografia em Camada Fina , Feminino , Hormônios Esteroides Gonadais/isolamento & purificação , Gônadas/efeitos dos fármacos , Gônadas/metabolismo , Hipotálamo/efeitos dos fármacos , Hipotálamo/metabolismo , Masculino , Radioimunoensaio , Testosterona/metabolismo
7.
J Pharm Biomed Anal ; 14(8-10): 1305-11, 1996 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8818049

RESUMO

The effect of temperature on the retention and multiple separation of hydrocortisone, testosterone, 17 alpha-methyltestosterone, prednisone, cortisone and 17 alpha-hydroxyprogesterone in reversed-phase liquid chromatography has been studied. Capacity factors (k') of the steroids were measured using a mobile phase modified with different concentrations of beta-cyclodextrin (from 0-16 mM), a fixed solvent composition (acetonitrile-water) and a wide range of column temperatures (from 5-80 degrees C). The plots of capacity factors vs. reciprocal of absolute temperature are nonlinear in every case when mobile phase modified with beta-cyclodextrin was used. Particularly strong nonlinearity was observed at lower temperature and at higher beta-cyclodextrin concentration. The complex chromatograms were evaluated using optimization parameters such as capacity factor of the last-eluted peak (k'max), the smallest resolution between adjacent peaks (Rs; min) and relative resolution product (r). The results presented describe precisely the role of temperature in high performance liquid chromatography systems in which mobile phases modified with cyclodextrin were used.


Assuntos
Ciclodextrinas , Pregnenos/isolamento & purificação , Testosterona/isolamento & purificação , beta-Ciclodextrinas , 17-alfa-Hidroxiprogesterona/análise , 17-alfa-Hidroxiprogesterona/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Cortisona/análise , Cortisona/isolamento & purificação , Hidrocortisona/análise , Hidrocortisona/isolamento & purificação , Indicadores e Reagentes , Cinética , Metiltestosterona/análise , Metiltestosterona/isolamento & purificação , Prednisona/análise , Prednisona/isolamento & purificação , Pregnenos/análise , Temperatura , Testosterona/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...