Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.253
Filtrar
1.
J. optom. (Internet) ; 17(3): [100508], jul.-sept2024. tab, graf
Artigo em Inglês | IBECS | ID: ibc-231874

RESUMO

Purpose: To report the visual and refractive characteristics and the prevalence of amblyopia in patients with different types of Duane's Retraction Syndrome (DRS). Method: This retrospective study was performed on hospital records of 582 DRS patients at Farabi Hospital, Iran, from 2012 to March 2022. Results: The mean age of patients was 19.4 ± 11.9 (range, 3–70) years [335 (57.6 %) females and 247 (42.4 %) males (P < .001)]. DRS type I, II, III, and IV were presented in 347 (59.6 %), 148 (25.4 %), 82 (14.1 %), and 5 (0.9 %) patients, respectively. There were 530 (91.1 %) patients with unilateral and 52 (8.9 %) with bilateral involvement. In the unilateral patients, the DRS eyes' corrected distance visual acuity (CDVA) and astigmatism were significantly worse than the Non-DRS Eyes (P < .001). The mean amount of all refractive and visual parameters in bilateral patients' right or left eyes was significantly lower than in unilateral patients' non-DRS eyes (all P < .05). Anisometropia was observed in 75(12.9 %) of the patients. Amblyopia was observed in 18.5 % (98 patients) and 36.5 % (19 patients) of unilateral and bilateral DRS patients, respectively (P < .001). In unilateral patients, amblyopia was found in 57 (16.4 %) patients with Type I, 22 (14.9 %) patients with Type II, 16 (19.5 %) patients with Type III, and 3 (60 %) patients with Type IV. Forty-four (37.6 %) of patients with amblyopia had anisometropia. Conclusion: This large-scale study indicates that DRS types differ in terms of refractive error, visual acuity, and the prevalence of amblyopia and anisometropia. Clinicians should be aware of the clinical features associated with different types of DRS.(AU)


Assuntos
Humanos , Masculino , Feminino , Visão Ocular , Ambliopia , Síndrome da Retração Ocular , Erros de Refração , Anisometropia
2.
BMC Ophthalmol ; 24(1): 239, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38849757

RESUMO

BACKGROUND: Functional visual impairments in children are primarily caused by amblyopia or strabismus. This study aimed to determine the prevalence and clinical profile of amblyopia and strabismus among individuals aged 3-16 years in Shanghai, China. METHODS: From February 2023 to February 2024, this hospital-based, cross-sectional study included data of children who visited the Ophthalmology Department of Shanghai General Hospital. Comprehensive ocular examinations included visual acuity measurement after cycloplegic refraction, slit lamp examination, cover test, and dilated fundus examination. Descriptive statistics were performed to estimate the proportion and clinical characteristics of amblyopia and strabismus. RESULTS: A total of 920 children were enrolled in our study. Among them, 223 (24.24%) children were identified as amblyopia. Unilateral amblyopia occupied 57.85%, and bilateral amblyopia occupied 42.15%. Most participants were within the age range of 5-10 years (75.97% for unilateral amblyopia, and 70.21% for bilateral amblyopia). Anisometropia was the primary cause of unilateral amblyopia (68.99%). Most amblyopic children have high hyperopia (38.76% for unilateral amblyopia, and 39.89% for bilateral amblyopia). 30 (3.26%) children were diagnosed with strabismus, and 19 (63.3%) of them were aged 5-10 years. Seven of the children had both strabismus and amblyopia. CONCLUSION: The proportion of patients with amblyopia and strabismus was determined as 24.24% and 3.26% in our study. Anisometropia was the leading cause of unilateral amblyopia, whereas high hyperopia was a crucial refractive error in the amblyopic population. These findings shed light on further longitudinal studies targeting the age-related changes in amblyopia, strabismus and refraction errors. Therefore, efforts should be made to manage uncorrected refractive errors, amblyopia, and strabismus among children in Shanghai.


Assuntos
Ambliopia , Erros de Refração , Estrabismo , Acuidade Visual , Humanos , Ambliopia/epidemiologia , Ambliopia/fisiopatologia , Ambliopia/diagnóstico , China/epidemiologia , Prevalência , Estudos Transversais , Criança , Pré-Escolar , Adolescente , Feminino , Masculino , Estrabismo/epidemiologia , Estrabismo/fisiopatologia , Erros de Refração/epidemiologia , Erros de Refração/fisiopatologia , Acuidade Visual/fisiologia , Distribuição por Idade , Refração Ocular/fisiologia
3.
Zhonghua Yan Ke Za Zhi ; 60(6): 490-493, 2024 Jun 11.
Artigo em Chinês | MEDLINE | ID: mdl-38825948

RESUMO

Multifocal intraocular lenses (MIOLs) have demonstrated efficacy and safety in adult cataract surgery, yet they encounter many challenges in pediatric applications. This article elaborates on the difficulties in biometric measurements in children, the unpredictability of postoperative refraction outcomes, the lack of long-term spectacle independence in children with MIOLs, the absence of significant advantages in correcting childhood amblyopia, and the potential increase in the rate of secondary surgeries. Due to the insufficient clinical evidence supporting the use of MIOLs in children at present, it is proposed that MIOLs be cautiously applied to children with congenital cataracts in clinical practice. Further research in this area is encouraged.


Assuntos
Extração de Catarata , Catarata , Implante de Lente Intraocular , Humanos , Catarata/congênito , Catarata/terapia , Criança , Implante de Lente Intraocular/métodos , Extração de Catarata/métodos , Lentes Intraoculares , Lentes Intraoculares Multifocais , Refração Ocular , Ambliopia , Acuidade Visual
4.
Invest Ophthalmol Vis Sci ; 65(5): 7, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38700875

RESUMO

Purpose: This study aimed to explore the underlying mechanisms of the observed visuomotor deficit in amblyopia. Methods: Twenty-four amblyopic (25.8 ± 3.8 years; 15 males) and 22 normal participants (25.8 ± 2.1 years; 8 males) took part in the study. The participants were instructed to continuously track a randomly moving Gaussian target on a computer screen using a mouse. In experiment 1, the participants performed the tracking task at six different target sizes. In experiments 2 and 3, they were asked to track a target with the contrast adjusted to individual's threshold. The tracking performance was represented by the kernel function calculated as the cross-correlation between the target and mouse displacements. The peak, latency, and width of the kernel were extracted and compared between the two groups. Results: In experiment 1, target size had a significant effect on the kernel peak (F(1.649, 46.170) = 200.958, P = 4.420 × 10-22). At the smallest target size, the peak in the amblyopic group was significantly lower than that in the normal group (0.089 ± 0.023 vs. 0.107 ± 0.020, t(28) = -2.390, P = 0.024) and correlated with the contrast sensitivity function (r = 0.739, P = 0.002) in the amblyopic eyes. In experiments 2 and 3, with equally visible stimuli, there were still differences in the kernel between the two groups (all Ps < 0.05). Conclusions: When stimulus visibility was compensated, amblyopic participants still showed significantly poorer tracking performance.


Assuntos
Ambliopia , Acuidade Visual , Humanos , Ambliopia/fisiopatologia , Masculino , Feminino , Adulto , Adulto Jovem , Acuidade Visual/fisiologia , Psicofísica/métodos , Percepção de Movimento/fisiologia , Sensibilidades de Contraste/fisiologia , Movimentos Oculares/fisiologia
5.
Vestn Oftalmol ; 140(2): 48-53, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742498

RESUMO

Purpose. The study investigates corneal and higher-order internal aberrations in patients with amblyopia of different etiologies and their relationship with visual acuity, refraction, axial length, and fixation parameters. MATERIAL AND METHODS: Forty-five patients (90 eyes) were examined. All patients were divided into five groups: 1 - with dysbinocular amblyopia; 2 - with refractive amblyopia; 3 - with anisometropic amblyopia; 4 - with relative amblyopia due to congenital myopia; 5 (control) - fellow eyes without amblyopia. Aberrometry was performed using the OPD-Scan III device (Nidek, Japan). Fixation parameters were studied on the MP-3 microperimeter (Nidek, Japan). Correlation analysis was performed using Pearson's linear correlation coefficient (r). RESULTS: In amblyopia associated with congenital myopia, a significant increase in corneal and internal aberrations RMS, Total HOA, astigmatism (V) (0.65±0.26; 1.01±0.31; 4.22±1.17; -2.17±0.72; 0.86±0.3, respectively; control group - 0.44±0.19; 0.58±0.27; 1.0±0.75; -0.94±0.89; 0.47±0.65) and internal spherical aberration (0.06±0.02; control group - 0.04±0.03) was found. In dysbinocular amblyopia, a significant increase in internal aberrations Trefoil (V) and Coma (H) (0.75±0.52 and 0.17±0.35, respectively; control group - 0.05±0.28 and -0.07±0.21) was found, which correlated with a decrease in fixation density in the 2° ring (r= -0.40, r= -0.41). CONCLUSIONS: The increased level of higher-order aberrations in amblyopia associated with congenital myopia is due to the anatomical and optical features of the eyes. The increase in internal aberrations Trefoil (V) and Coma (H) in dysbinocular amblyopia is associated with a mismatch of the optical elements of the eye due to impaired fixation, i.e., it is not the cause, but the consequence of amblyopia.


Assuntos
Ambliopia , Miopia , Acuidade Visual , Humanos , Ambliopia/etiologia , Ambliopia/fisiopatologia , Ambliopia/diagnóstico , Masculino , Criança , Feminino , Miopia/complicações , Miopia/fisiopatologia , Miopia/diagnóstico , Refração Ocular/fisiologia , Aberrometria/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Aberrações de Frente de Onda da Córnea/diagnóstico
6.
Zhonghua Yan Ke Za Zhi ; 60(5): 440-446, 2024 May 11.
Artigo em Chinês | MEDLINE | ID: mdl-38706082

RESUMO

Objective: To explore the differences in clinical characteristics and interocular interactions between patients with anisometropic amblyopia and ametropic amblyopia. Methods: Cross-sectional study. The newly diagnosed anisometropic (the binocular difference in spherical equivalent≥1.00 D) amblyopia patients and ametropic amblyopia patients (aged 4 to 6 years) in Beijing Tongren Hospital from January 2020 to December 2022 were involved. Patients were further categorized by the refractive status after cycloplegia, including hyperopia, myopia, astigmatism, hyperopia with astigmatism, myopia with astigmatism, mild anisometropia and severe anisometropia. Quantitative measurements of best-corrected visual acuity (logMAR), stereoacuity (transformed to log units), perceptual eye position and interocular suppression were performed, and the differences between groups were analyzed. The rank sum test was used for statistical evaluation. Results: The average age of 45 ametropic amblyopia patients (21 males and 24 females) and 84 anisometropic amblyopia patients (48 males and 36 females) was 5.0 (4.0, 5.0) years and 5.0 (4.0, 6.0) years, respectively. The interocular differences in spherical equivalent [2.56 (1.50, 4.19) D vs. 0.25 (0.13, 0.56) D] and best-corrected visual acuity [0.40 (0.18, 0.70) logMAR vs. 0.07 (0.00, 0.12) logMAR] were larger in patients with anisometropic amblyopia than those with ametropic amblyopia. The anisometropic amblyopia patients had worse stereoacuity [2.60 (2.00, 2.90) log arcsec vs. 2.00 (2.00, 2.30) log arcsec] and deeper suppression [20.0% (13.3%, 40.0%) vs. 10.0% (0, 23.3%)], compared with the ametropic amblyopia patients. The differences were all statistically significant (P<0.05). The suppression and stereoacuity between patients with hyperopic anisometropic amblyopia [suppression, 30.0% (17.5%, 50.0%); stereoacuity, 2.90 (2.30, 2.90) log arcsec] and astigmatic anisometropic amblyopia [suppression, 10.0% (0, 20.0%); stereoacuity, 2.00 (2.00, 2.30) log arcsec] were significantly different (P<0.05). The differences of suppression and stereoacuity between patients with severe (binocular difference in spherical equivalent>2.50 D) [suppression, 30.0% (20.0%, 53.3%); stereoacuity, 2.90 (2.57, 2.90) log arcsec] and mild anisometropia [suppression, 20.0% (0, 30.0%); stereoacuity, 2.00 (2.00, 2.90) log arcsec] were also statistically significant (P<0.05). Conclusions: Patients with anisometropic amblyopia have deeper binocular suppression, worse stereoacuity and more severe binocular interaction abnormality than those with ametropic amblyopia. The severity of anisometropia affects the degree of the interaction abnormality.


Assuntos
Ambliopia , Miopia , Visão Binocular , Humanos , Ambliopia/fisiopatologia , Masculino , Feminino , Estudos Transversais , Pré-Escolar , Miopia/complicações , Acuidade Visual , Criança , Astigmatismo , Anisometropia/complicações , Hiperopia/fisiopatologia
9.
Lancet ; 403(10438): 1766-1778, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38704172

RESUMO

BACKGROUND: Amblyopia, the most common visual impairment of childhood, is a public health concern. An extended period of optical treatment before patching is recommended by the clinical guidelines of several countries. The aim of this study was to compare an intensive patching regimen, with and without extended optical treatment (EOT), in a randomised controlled trial. METHODS: EuPatch was a randomised controlled trial conducted in 30 hospitals in the UK, Greece, Austria, Germany, and Switzerland. Children aged 3-8 years with newly detected, untreated amblyopia (defined as an interocular difference ≥0·30 logarithm of the minimum angle of resolution [logMAR] best corrected visual acuity [BCVA]) due to anisometropia, strabismus, or both were eligible. Participants were randomly assigned (1:1) via a computer-generated sequence to either the EOT group (18 weeks of glasses use before patching) or to the early patching group (3 weeks of glasses use before patching), stratified for type and severity of amblyopia. All participants were initially prescribed an intensive patching regimen (10 h/day, 6 days per week), supplemented with motivational materials. The patching period was up to 24 weeks. Participants, parents or guardians, assessors, and the trial statistician were not masked to treatment allocation. The primary outcome was successful treatment (ie, ≤0·20 logMAR interocular difference in BCVA) after 12 weeks of patching. Two primary analyses were conducted: the main analysis included all participants, including those who dropped out, but excluded those who did not provide outcome data at week 12 and remained on the study; the other analysis imputed this missing data. All eligible and randomly assigned participants were assessed for adverse events. This study is registered with the International Standard Randomised Controlled Trial Number registry (ISRCTN51712593) and is no longer recruiting. FINDINGS: Between June 20, 2013, and March 12, 2020, after exclusion of eight participants found ineligible after detailed screening, we randomly assigned 334 participants (170 to the EOT group and 164 to the early patching group), including 188 (56%) boys, 146 (44%) girls, and two (1%) participants whose sex was not recorded. 317 participants (158 in the EOT group and 159 in the early patching group) were analysed for the primary outcome without imputation of missing data (median follow-up time 42 weeks [IQR 42] in the EOT group vs 27 weeks [27] in the early patching group). 24 (14%) of 170 participants in the EOT group and ten (6%) of 164 in the early patching group were excluded or dropped out of the study, mostly due to loss to follow-up and withdrawal of consent; ten (6%) in the EOT group and three (2%) in the early patching group missed the 12 week visit but remained on the study. A higher proportion of participants in the early patching group had successful treatment (107 [67%] of 159) than those in the EOT group (86 [54%] of 158; 13% difference; p=0·019) after 12 weeks of patching. No serious adverse events related to the interventions occurred. INTERPRETATION: The results from this trial indicate that early patching is more effective than EOT for the treatment of most children with amblyopia. Our findings also provide data for the personalisation of amblyopia treatments. FUNDING: Action Medical Research, NIHR Clinical Research Network, and Ulverscroft Foundation.


Assuntos
Ambliopia , Óculos , Privação Sensorial , Acuidade Visual , Humanos , Ambliopia/terapia , Pré-Escolar , Feminino , Masculino , Criança , Resultado do Tratamento , Europa (Continente)
10.
Curr Opin Ophthalmol ; 35(4): 292-297, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38704713

RESUMO

PURPOSE OF REVIEW: Pediatric refractive surgery has been growing at a steady pace since its introduction in the early 1980 s. This article will review common laser refractive surgeries performed on pediatric patients along with controversies regarding the practice. RECENT FINDINGS: Pediatric refractive surgery is reserved for a small population of children who fail amblyopic treatment due to high anisometropic refractive errors. Publications over the years have treated these children with various types of laser refractive surgery. SUMMARY: Laser pediatric refractive surgery appears to be well tolerated and effective for the population of children that need it. It provides an alternative for anisometropic amblyopia treatment for children who would have otherwise not been able to improve their vision.


Assuntos
Ambliopia , Procedimentos Cirúrgicos Refrativos , Humanos , Criança , Ambliopia/cirurgia , Procedimentos Cirúrgicos Refrativos/métodos , Oftalmologia/tendências , Pré-Escolar , Erros de Refração , Anisometropia/cirurgia
11.
Invest Ophthalmol Vis Sci ; 65(5): 31, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38771572

RESUMO

Purpose: Although effective amblyopia treatments are available, treatment outcome is unpredictable, and the condition recurs in up to 25% of the patients. We aimed to evaluate whether a large-scale quantitative contrast sensitivity function (CSF) data source, coupled with machine learning (ML) algorithms, can predict amblyopia treatment response and recurrence in individuals. Methods: Visual function measures from traditional chart vision acuity (VA) and novel CSF assessments were used as the main predictive variables in the models. Information from 58 potential predictors was extracted to predict treatment response and recurrence. Six ML methods were applied to construct models. The SHapley Additive exPlanations was used to explain the predictions. Results: A total of 2559 consecutive records of 643 patients with amblyopia were eligible for modeling. Combining variables from VA and CSF assessments gave the highest accuracy for treatment response prediction, with the area under the receiver operating characteristic curve (AUC) of 0.863 and 0.815 for outcome predictions after 3 and 6 months, respectively. Variables from the VA assessment alone predicted the treatment response, with AUC values of 0.723 and 0.675 after 3 and 6 months, respectively. Variables from the CSF assessment gave rise to an AUC of 0.909 for recurrence prediction compared to 0.539 for VA assessment alone, and adding VA variables did not improve predictive performance. The interocular differences in CSF features are significant contributors to recurrence risk. Conclusions: Our models showed CSF data could enhance treatment response prediction and accurately predict amblyopia recurrence, which has the potential to guide amblyopia management by enabling patient-tailored decision making.


Assuntos
Ambliopia , Sensibilidades de Contraste , Recidiva , Acuidade Visual , Humanos , Ambliopia/terapia , Ambliopia/fisiopatologia , Ambliopia/diagnóstico , Acuidade Visual/fisiologia , Masculino , Feminino , Sensibilidades de Contraste/fisiologia , Criança , Resultado do Tratamento , Pré-Escolar , Curva ROC , Aprendizado de Máquina , Estudos Retrospectivos , Adolescente , Privação Sensorial , Algoritmos
12.
Medicine (Baltimore) ; 103(20): e38143, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758890

RESUMO

This study was aimed to analyze ocular biometric changes following cycloplegia in pediatric patients with strabismus and amblyopia. Cycloplegia is routinely used to measure refractive error accurately by paralyzing accommodation. However, effects on axial length (AL), anterior chamber depth (ACD), keratometry (Km), and white-to-white distance (WTW) are not well studied in this population. This retrospective study examined 797 patients (1566 eyes) undergoing cycloplegic refraction at a Samsung Kangbuk hospital pediatric ophthalmology clinic from 2010 to 2023. Ocular biometry was measured before and after instilling 1% cyclopentolate and 0.5% phenylephrine/0.5% tropicamide. Patients were categorized by strabismus diagnosis, age, refractive error and amblyopia status. Differences in AL, ACD, Km, WTW, and refractive error pre- and post-cycloplegia were analyzed using paired t tests. ACD (3.44 ±â€…0.33 vs 3.58 ±â€…0.29 mm, P < .05) and WTW (12.09 ±â€…0.42 vs 12.30 ±â€…0.60 mm, P < .05) increased significantly after cycloplegia in all groups except other strabismus subgroup (Cs) in both parameters and youngest subgroup (G1) in ACD. Refractive error demonstrated a hyperopic shift from -0.48 ±â€…3.00 D to -0.06 ±â€…3.32 D (P < .05) in overall and a myopic shift from -6.97 ±â€…4.27 to -8.10 ±â€…2.26 in high myopia (HM). Also, AL and Km did not change significantly. In conclusion, cycloplegia impacts ocular biometrics in children with strabismus and amblyopia, significantly increasing ACD and WTW. Refractive error shifts hyperopically in esotropia subgroup (ET) and myopically in high myopia subgroup (HM), eldest subgroup (G3) relating more to anterior segment changes than AL/Km. Understanding cycloplegic effects on biometry is important for optimizing refractive correction in these patients.


Assuntos
Ambliopia , Biometria , Ciclopentolato , Midriáticos , Refração Ocular , Estrabismo , Humanos , Ambliopia/fisiopatologia , Estrabismo/fisiopatologia , Estudos Retrospectivos , Masculino , Feminino , Criança , Biometria/métodos , Midriáticos/administração & dosagem , Midriáticos/farmacologia , Pré-Escolar , Refração Ocular/efeitos dos fármacos , Refração Ocular/fisiologia , Ciclopentolato/administração & dosagem , Erros de Refração/fisiopatologia , Adolescente , Câmara Anterior/efeitos dos fármacos , Câmara Anterior/patologia , Comprimento Axial do Olho
13.
Ophthalmic Physiol Opt ; 44(5): 945-953, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38757545

RESUMO

PURPOSE: The improvement in visual acuity (VA) was determined during optical treatment in children with amblyopia before their participation in a randomised clinical trial comparing the effect of dichoptic video gaming using virtual reality goggles with occlusion therapy. METHODS: Children aged 4-12 years with an interocular VA difference ≥0.20 logMAR and an amblyogenic factor: strabismus <30Δ, ≥1.00 D anisometropia, astigmatism ≥1.50 D and/or hypermetropia ≥1.50 D were eligible for 16 weeks of optical treatment. Children with previous amblyopia treatment were excluded. Compliance with spectacle wear was measured electronically over 1 week using the occlusion dose monitor (ODM). The reliability of these measurements was verified. The main outcome was an increase in amblyopic eye VA from baseline to 16 weeks. RESULTS: Sixty-five children entered the optical treatment period. Mean age was 6.0 ± 2.2 years (range: 4-12 years; IQR 4.5-6.7 years). Amblyopia was caused by anisometropia in 53 (82%) children, strabismus in 6 (9%) and combined mechanism in 6 (9%). After optical treatment, mean VA improved by 0.20 logMAR (SD 0.28; p < 0.001) and 0.07 in the amblyopic and fellow eye, respectively (SD 0.20; p = 0.03). This resulted in 24 children (37%) with an interocular VA difference <0.20 logMAR and in 17% of children with VA at the start of 0.30 logMAR or worse. Poor VA in the amblyopic eye at baseline (p = 0.001) and high anisometropia (p = 0.001) were associated with VA improvement. On average, spectacles were worn 9.7 ± 2.4 h/day (range: 2.3-13.6 h); mean compliance was 73% ± 18% of estimated wake time. Only ambient temperature ≥ 31°C or when spectacles were worn on top of the head prevented a reliable ODM measurement. CONCLUSIONS: VA improved by two lines resulting in more than a third of the children being treated sufficiently with spectacles alone and no longer being classified as amblyopic. The ODM proved to be a reliable method of measuring compliance with spectacle wear.


Assuntos
Ambliopia , Óculos , Cooperação do Paciente , Acuidade Visual , Humanos , Ambliopia/terapia , Ambliopia/fisiopatologia , Pré-Escolar , Criança , Acuidade Visual/fisiologia , Feminino , Masculino , Cooperação do Paciente/estatística & dados numéricos , Reprodutibilidade dos Testes , Privação Sensorial , Resultado do Tratamento , Visão Binocular/fisiologia , Jogos de Vídeo
14.
Transl Vis Sci Technol ; 13(5): 21, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38780954

RESUMO

Purpose: This study aimed to investigate the possible relationship between retinal vascular abnormalities and amblyopia by analyzing vascular structures of fundus images. Methods: In this observational study, retinal fundus images were collected from 36 patients with unilateral amblyopia, 33 patients with bilateral amblyopia, and 36 healthy control volunteers. We developed a customized training algorithm based on U-Net to digitalize the vasculature in the fundus images to quantify vascular density (area and fractal dimension), skeleton length, and number of bifurcation points. For statistical comparisons, this study divided participants into two groups. The amblyopic eyes and the fellow eyes of patients with unilateral amblyopia formed the paired group, while bilateral amblyopic patients and healthy controls formed the independent group. Results: In the paired group, the vascular area (P = 0.007), vascular fractal dimension (P = 0.007), and vascular skeleton length (P = 0.002) of the amblyopic eyes were significantly smaller than those of the fellow eyes. In the independent group, significant decreases in the vascular fractal dimension (P = 0.006) and skeleton length (P = 0.048) were observed in bilateral amblyopia compared to control. The vascular area was also significantly correlated with best-corrected visual acuity in amblyopic eyes. Conclusions: This study demonstrated that retinal vascular density and skeleton length in amblyopic eyes were significantly smaller compared to control, indicating an association between the changes in retinal vascular features and the state of amblyopia. Translational Relevance: Our algorithm presents amblyopic retinal vascular changes that are more biologically interpretable for both clinicians and researchers.


Assuntos
Algoritmos , Ambliopia , Vasos Retinianos , Acuidade Visual , Humanos , Ambliopia/fisiopatologia , Ambliopia/patologia , Feminino , Masculino , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Acuidade Visual/fisiologia , Adulto , Adulto Jovem , Adolescente , Criança , Fractais , Densidade Microvascular
15.
Arch. Soc. Esp. Oftalmol ; 99(5): 205-208, May. 2024. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-VR-71

RESUMO

El síndrome de Bardet-Biedl (SBB) es una ciliopatía que se asocia principalmente a distrofia retiniana, disfunción renal, polidactilia posaxial, obesidad, déficit cognitivo e hipogonadismo. Los síntomas vinculados a la distrofia retiniana no suelen aparecer hasta la primera década de vida, por lo que la detección tiende a retrasarse. La afectación ocular puede ser la forma inicial de manifestación de este síndrome, incluso puede ser la única, por lo que se debería tener en cuenta en el diagnóstico diferencial de una ambliopía en un niño que no mejora a pesar del correcto cumplimiento del tratamiento. Se presenta un caso de baja agudeza visual (AV) en una paciente pediátrica como manifestación inicial que lleva al diagnóstico del SBB y que es, además, el único síntoma que exhibe hasta la fecha, a pesar de tratarse de una enfermedad multisistémica.(AU)


Bardet–Biedl syndrome is a ciliopathy mainly associated with retinal dystrophy, renal dysfunction, post-axial polydactyly, obesity, cognitive deficit and hypogonadism. The symptoms associated with retinal dystrophy do not usually appear until the first decade of life, so the diagnosis is usually delayed. Ocular involvement may be the initial form of manifestation of this syndrome, it may even be the only one, so it should be taken into account in the differential diagnosis of amblyopia in a child who does not improve despite correct compliance with treatment. A case of low visual acuity in a pediatric patient is presented as an initial manifestation that leads to the diagnosis of Bardet–Biedl syndrome, and which is also the only symptom that the patient presents to date, despite being a multisystem disease.(AU)


Assuntos
Humanos , Feminino , Síndrome de Bardet-Biedl , Oftalmopatias , Visão Ocular , Degeneração Macular , Ambliopia , Distrofias Retinianas , Pacientes Internados , Exame Físico , Oftalmologia
16.
Turk J Ophthalmol ; 54(2): 90-102, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38645732

RESUMO

Congenital cataract is among the main causes of treatable vision loss in childhood. The first weeks and months of life are a critical time for the development of vision. Therefore, early cataract surgery and effective multifaceted treatment of the resulting aphakia in the early stages of life are of great value for the management of vision development. Among the treatment models, contact lenses (CL) have an important place in infancy and early childhood up to the age of 2 years. Although good visual gains were not considered very likely, especially in unilateral aphakia, important steps have been taken in the treatment of pediatric aphakia thanks to the surgical techniques developed over time and the increasing experience with optical correction systems, especially CLs. This review examines current developments in the types of CL used in pediatric aphakia, their application features, comparison with other optical systems, the features of amblyopia treatment in the presence of CL, and the results obtained with family compliance to CL wear and occlusion therapy in the light of existing studies.


Assuntos
Afacia Pós-Catarata , Lentes de Contato , Acuidade Visual , Humanos , Afacia Pós-Catarata/terapia , Afacia Pós-Catarata/fisiopatologia , Acuidade Visual/fisiologia , Lactente , Pré-Escolar , Catarata/congênito , Extração de Catarata/métodos , Ambliopia/terapia , Ambliopia/fisiopatologia , Afacia , Criança , Recém-Nascido
17.
Invest Ophthalmol Vis Sci ; 65(4): 15, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38587443

RESUMO

Purpose: The purpose of this study was to understand how monocular luminance reduction affects binocular balance and examine whether it differentially influences fusion and mixed perception in amblyopia. Methods: Twenty-three normally sighted observers and 12 adults with amblyopia participated in this study. A novel binocular rivalry task was used to measure the phase duration of four perceptual responses (right- and left-tilts, fusion, and mixed perception) before and after a neutral density (ND) filter was applied at various levels to the dominant eye (DE) of controls and the fellow eye (FE) of patients with amblyopia. Phase durations were analyzed to assess whether the duration of fusion or mixed perception shifted after monocular luminance reduction. Moreover, we quantified ocular dominance and adjusted monocular contrast and luminance separately to investigate the relationship between changes in ocular dominance induced by the two manipulations. Results: In line with previous studies, binocular balance shifted in favor of the brighter eye in both normal adults and patients with amblyopia. As a function of the ND filter's density, the duration of fusion and mixed perception decreased in normal controls, whereas that of fusion but not mixed perception increased significantly in patients with amblyopia. In addition, changes in binocular balance from luminance reduction were more significant in more balanced amblyopes or normal observers. Furthermore, shifts in binocular balance after contrast and luminance modulation were correlated in both normal and amblyopic observers. Conclusions: The duration of fusion but not mixed perception increased in amblyopia after monocular luminance reduction in the FE. Moreover, our findings demonstrate that changes in ocular dominance from contrast-modulation and luminance-modulation are correlated in both normal and amblyopic observers.


Assuntos
Ambliopia , Adulto , Humanos , Dominância Ocular , Percepção
18.
Invest Ophthalmol Vis Sci ; 65(4): 13, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38573617

RESUMO

Purpose: The purpose of this study was to assess motion-defined form perception, including the association with clinical and sensory factors that may drive performance, in each eye of children with deprivation amblyopia due to unilateral cataract. Methods: Coherence thresholds for orientation discrimination of motion-defined form were measured using a staircase procedure in 30 children with deprivation amblyopia and 59 age-matched controls. Visual acuity, stereoacuity, fusion, and interocular suppression were also measured. Fixation stability and fellow-eye global motion thresholds were measured in a subset of children. Results: Motion-defined form coherence thresholds were elevated in 90% of children with deprivation amblyopia when viewing with the amblyopic eye and in 40% when viewing with the fellow eye. The deficit was similar in children with a cataract that had been visually significant at birth (congenital) and in children for whom the cataract appeared later in infancy or childhood (developmental). Poorer motion-defined form perception in amblyopic eyes was associated with poorer visual acuity, poorer binocular function, greater interocular suppression, and the presence of nystagmus. Fellow-eye deficits were not associated with any of these factors, but a temporo-nasal asymmetry for global motion perception in favor of nasalward motion suggested a general disruption in motion perception. Conclusions: Deficits in motion-defined form perception are common in children with deprivation amblyopia and may reflect a problem in motion processing that relies on binocular mechanisms.


Assuntos
Ambliopia , Catarata , Percepção de Forma , Percepção de Movimento , Recém-Nascido , Criança , Humanos , Olho
19.
Optom Vis Sci ; 101(4): 187-194, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38684061

RESUMO

SIGNIFICANCE: Results of this study provide preliminary data on parent strategies for improving compliance with eyeglass treatment in young children, an age group for which previous data are limited. Parent responses provide important insights to support parents of young children who wear eyeglasses and provide preliminary data to guide additional research. PURPOSE: The goal of this exploratory study was to learn more about parents' strategies to improve compliance with eyeglass treatment of young children. METHODS: An online survey of parents of 1-year-old to less than 5-year-old children who wear eyeglasses was conducted. Parents indicated whether they used various strategies to encourage wear and were asked to provide advice for parents of young children recently prescribed eyeglasses. Use of various strategies by age was determined. Open-ended responses regarding advice for other parents were analyzed using qualitative content analysis. RESULTS: The final sample included 104 parents who were predominantly White (81%), non-Hispanic (76%), and college graduates (68%). During the 2 weeks prior to survey completion, 74% of parents reported their child wore their eyeglasses ≥8 hours/day. Use of strategies for improving eyeglass wear varied by child age. The most frequent recommendations that parents provided for other parents were to be consistent in encouraging wear, use social modeling, provide positive reinforcement when the eyeglasses are worn, and ensure that the eyeglasses fit well and were comfortable. CONCLUSIONS: Parents provided many useful insights into their experiences. However, results may not be broadly generalizable, because of the limited diversity and high rate of compliance in the study sample. Further research with more diverse populations and research on effectiveness of various strategies to increase compliance in this age group are recommended to support eyeglass treatment compliance in young children.


Assuntos
Óculos , Pais , Cooperação do Paciente , Humanos , Pré-Escolar , Feminino , Masculino , Lactente , Inquéritos e Questionários , Ambliopia/terapia , Ambliopia/fisiopatologia , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...