Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.685
Filtrar
1.
BMC Ophthalmol ; 24(1): 239, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38849757

RESUMO

BACKGROUND: Functional visual impairments in children are primarily caused by amblyopia or strabismus. This study aimed to determine the prevalence and clinical profile of amblyopia and strabismus among individuals aged 3-16 years in Shanghai, China. METHODS: From February 2023 to February 2024, this hospital-based, cross-sectional study included data of children who visited the Ophthalmology Department of Shanghai General Hospital. Comprehensive ocular examinations included visual acuity measurement after cycloplegic refraction, slit lamp examination, cover test, and dilated fundus examination. Descriptive statistics were performed to estimate the proportion and clinical characteristics of amblyopia and strabismus. RESULTS: A total of 920 children were enrolled in our study. Among them, 223 (24.24%) children were identified as amblyopia. Unilateral amblyopia occupied 57.85%, and bilateral amblyopia occupied 42.15%. Most participants were within the age range of 5-10 years (75.97% for unilateral amblyopia, and 70.21% for bilateral amblyopia). Anisometropia was the primary cause of unilateral amblyopia (68.99%). Most amblyopic children have high hyperopia (38.76% for unilateral amblyopia, and 39.89% for bilateral amblyopia). 30 (3.26%) children were diagnosed with strabismus, and 19 (63.3%) of them were aged 5-10 years. Seven of the children had both strabismus and amblyopia. CONCLUSION: The proportion of patients with amblyopia and strabismus was determined as 24.24% and 3.26% in our study. Anisometropia was the leading cause of unilateral amblyopia, whereas high hyperopia was a crucial refractive error in the amblyopic population. These findings shed light on further longitudinal studies targeting the age-related changes in amblyopia, strabismus and refraction errors. Therefore, efforts should be made to manage uncorrected refractive errors, amblyopia, and strabismus among children in Shanghai.


Assuntos
Ambliopia , Erros de Refração , Estrabismo , Acuidade Visual , Humanos , Ambliopia/epidemiologia , Ambliopia/fisiopatologia , Ambliopia/diagnóstico , China/epidemiologia , Prevalência , Estudos Transversais , Criança , Pré-Escolar , Adolescente , Feminino , Masculino , Estrabismo/epidemiologia , Estrabismo/fisiopatologia , Erros de Refração/epidemiologia , Erros de Refração/fisiopatologia , Acuidade Visual/fisiologia , Distribuição por Idade , Refração Ocular/fisiologia
2.
BMC Ophthalmol ; 24(1): 250, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38867144

RESUMO

BACKGROUND AND AIM: Refractive errors, amblyopia, strabismus, and low vision are more common among children with hearing impairments in comparison with their hearing peers. Neglecting visual disorders can pose educational and social problems for these children. The present study aimed to assess the prevalence of refractive errors, amblyopia, strabismus, and low vision among hearing-impaired and deaf students in Kermanshah. MATERIALS AND METHODS: A total of 79 deaf and hearing impaired students within the age range of 7-20 years (mean age of 15.01 ± 2.72) underwent optometric examinations, including autorefractometry, retinoscopy, ophthalmoscopy, slit lamp, visual acuity measurement, and cover-uncover test. Those who needed further evaluation were referred to the Ophthalmology Clinic of Imam Khomeini Hospital. RESULTS: Regarding the prevalence of refractive errors, 32 (40.5%) subjects had one or a combination of refractive errors, the most common of which was astigmatism (36.7%), followed by amblyopia (15.1%). The most common type of strabismus was latent strabismus (heterophoria) (88.6%), followed by exophoria (81%). Moreover, 3 (3.7%) cases had nystagmus. A significant difference was observed between the prevalence of amblyopia and the degree of hearing loss (P = 0.026), and no significant difference was detected in other cases. CONCLUSION: As evidenced by the obtained results, refractive errors, amblyopia, strabismus, and low vision are more prevalent among deaf and hearing-impaired children compared to normal children because deaf and hearing-impaired children are not able to convey their vision problems and need to compensate for their poor hearing with an enhanced sense of sight, inattention to these disorders can present these children with serious educational and social problems. Therefore, eye screening examinations are of paramount importance in deaf and hearing-impaired children.


Assuntos
Ambliopia , Erros de Refração , Estrabismo , Baixa Visão , Acuidade Visual , Humanos , Estrabismo/epidemiologia , Estrabismo/fisiopatologia , Criança , Adolescente , Masculino , Feminino , Erros de Refração/epidemiologia , Erros de Refração/fisiopatologia , Erros de Refração/complicações , Baixa Visão/epidemiologia , Ambliopia/epidemiologia , Ambliopia/fisiopatologia , Ambliopia/diagnóstico , Prevalência , Adulto Jovem , Acuidade Visual/fisiologia , Irã (Geográfico)/epidemiologia , Estudos Transversais , Pessoas com Deficiência Auditiva , Surdez/epidemiologia , Estudantes
3.
Medicine (Baltimore) ; 103(25): e38488, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38905427

RESUMO

To evaluate the usefulness of the Tokyo Metropolitan Government's Eye Health Screening Program for 3-year-old children, which combines the Single-Picture Optotype Visual Acuity Chart (SPVAC) and Spot™ Vision Screener (SVS) tests. This was a retrospective, observational, matched study. Patients who underwent the eye health screening program and had abnormalities were classified into 3 groups according to the outcomes of the SPVAC (SPVAC-passed, SPVAC-P; SPVAC-failed, SPVAC-F) and SVS (SVS-passed, SVS-P; SVS-failed, SVS-F) tests as follows: SPVAC-P/SVS-F, SPVAC-F/SVS-P, and SPVAC-F/SVS-F. We evaluated the age at examination, SPVAC and SVS test success rates, and SVS refractive power. Additionally, the rates of refractive error, amblyopia, and strabismus were compared among the 3 groups. The SPVAC-P/SVS-F, SPVAC-F/SVS-P, and SPVAC-F/SVS-F groups comprised 158, 28, and 74 eyes, respectively. The mean age was 37.4 months. The success rates of the SPVAC and SVS tests were 69.8% and 96.2%, respectively. The mean SVS hyperopia value in the SPVAC-F/SVS-F group (2.71 ±â€…1.50 D) was significantly higher than that of the SPVAC-P/SVS-F group. The mean SVS astigmatism and myopia values were -2.21 diopter (D) ±â€…1.09 D and -3.40 ±â€…1.82 D, respectively; they did not differ significantly from that of the SPVAC-P/SVS-F group. Significant differences were observed in the refractive error, amblyopia, and strabismus rates among the 3 groups. Regarding disease determination, no significant difference was observed among participants who passed and failed the SPVAC test, regardless of the outcome of the other test. However, a significant difference was observed between those passing and failing the SVS tests. The SPVAC method used to screen 3-year-old children should be modified to commence at 42 months of age or be replaced with a single Landolt C test. The SVS test is useful for screening younger patients. Furthermore, the SVS test showed that the degree of hyperopia was higher in patients who did not pass the SPVAC test.


Assuntos
Estrabismo , Seleção Visual , Acuidade Visual , Humanos , Estudos Retrospectivos , Pré-Escolar , Masculino , Feminino , Seleção Visual/métodos , Seleção Visual/instrumentação , Tóquio , Estrabismo/diagnóstico , Erros de Refração/diagnóstico , Ambliopia/diagnóstico , Testes Visuais/métodos
4.
Vestn Oftalmol ; 140(2): 48-53, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742498

RESUMO

Purpose. The study investigates corneal and higher-order internal aberrations in patients with amblyopia of different etiologies and their relationship with visual acuity, refraction, axial length, and fixation parameters. MATERIAL AND METHODS: Forty-five patients (90 eyes) were examined. All patients were divided into five groups: 1 - with dysbinocular amblyopia; 2 - with refractive amblyopia; 3 - with anisometropic amblyopia; 4 - with relative amblyopia due to congenital myopia; 5 (control) - fellow eyes without amblyopia. Aberrometry was performed using the OPD-Scan III device (Nidek, Japan). Fixation parameters were studied on the MP-3 microperimeter (Nidek, Japan). Correlation analysis was performed using Pearson's linear correlation coefficient (r). RESULTS: In amblyopia associated with congenital myopia, a significant increase in corneal and internal aberrations RMS, Total HOA, astigmatism (V) (0.65±0.26; 1.01±0.31; 4.22±1.17; -2.17±0.72; 0.86±0.3, respectively; control group - 0.44±0.19; 0.58±0.27; 1.0±0.75; -0.94±0.89; 0.47±0.65) and internal spherical aberration (0.06±0.02; control group - 0.04±0.03) was found. In dysbinocular amblyopia, a significant increase in internal aberrations Trefoil (V) and Coma (H) (0.75±0.52 and 0.17±0.35, respectively; control group - 0.05±0.28 and -0.07±0.21) was found, which correlated with a decrease in fixation density in the 2° ring (r= -0.40, r= -0.41). CONCLUSIONS: The increased level of higher-order aberrations in amblyopia associated with congenital myopia is due to the anatomical and optical features of the eyes. The increase in internal aberrations Trefoil (V) and Coma (H) in dysbinocular amblyopia is associated with a mismatch of the optical elements of the eye due to impaired fixation, i.e., it is not the cause, but the consequence of amblyopia.


Assuntos
Ambliopia , Miopia , Acuidade Visual , Humanos , Ambliopia/etiologia , Ambliopia/fisiopatologia , Ambliopia/diagnóstico , Masculino , Criança , Feminino , Miopia/complicações , Miopia/fisiopatologia , Miopia/diagnóstico , Refração Ocular/fisiologia , Aberrometria/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Aberrações de Frente de Onda da Córnea/diagnóstico
5.
Invest Ophthalmol Vis Sci ; 65(5): 31, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38771572

RESUMO

Purpose: Although effective amblyopia treatments are available, treatment outcome is unpredictable, and the condition recurs in up to 25% of the patients. We aimed to evaluate whether a large-scale quantitative contrast sensitivity function (CSF) data source, coupled with machine learning (ML) algorithms, can predict amblyopia treatment response and recurrence in individuals. Methods: Visual function measures from traditional chart vision acuity (VA) and novel CSF assessments were used as the main predictive variables in the models. Information from 58 potential predictors was extracted to predict treatment response and recurrence. Six ML methods were applied to construct models. The SHapley Additive exPlanations was used to explain the predictions. Results: A total of 2559 consecutive records of 643 patients with amblyopia were eligible for modeling. Combining variables from VA and CSF assessments gave the highest accuracy for treatment response prediction, with the area under the receiver operating characteristic curve (AUC) of 0.863 and 0.815 for outcome predictions after 3 and 6 months, respectively. Variables from the VA assessment alone predicted the treatment response, with AUC values of 0.723 and 0.675 after 3 and 6 months, respectively. Variables from the CSF assessment gave rise to an AUC of 0.909 for recurrence prediction compared to 0.539 for VA assessment alone, and adding VA variables did not improve predictive performance. The interocular differences in CSF features are significant contributors to recurrence risk. Conclusions: Our models showed CSF data could enhance treatment response prediction and accurately predict amblyopia recurrence, which has the potential to guide amblyopia management by enabling patient-tailored decision making.


Assuntos
Ambliopia , Sensibilidades de Contraste , Recidiva , Acuidade Visual , Humanos , Ambliopia/terapia , Ambliopia/fisiopatologia , Ambliopia/diagnóstico , Acuidade Visual/fisiologia , Masculino , Feminino , Sensibilidades de Contraste/fisiologia , Criança , Resultado do Tratamento , Pré-Escolar , Curva ROC , Aprendizado de Máquina , Estudos Retrospectivos , Adolescente , Privação Sensorial , Algoritmos
8.
Photodiagnosis Photodyn Ther ; 46: 104073, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38570151

RESUMO

PURPOSE: This research evaluates the effectiveness of the Spot Vision Screener (SVS) before and after cycloplegia to detect amblyogenic refractive errors in children. METHODS: Children ages 3 to 10 years old were screened by the SVS before and after cycloplegia. Sensitivity, specificity, positive and negative predictive value, paired t-test, Bland-Altman plot and receiver operating characteristic area under the curve were evaluated by comparing the results of the SVS (v3.0.05) measurements with the results of the cycloplegic Topcon autorefractometer according to the 2021 guidelines of the American Association for Pediatric Ophthalmology and Strabismus. RESULTS: Both eyes of 211 patients aged 3 to 10 years old were included. Regarding the amblyopia risk factors, the noncycloplegic SVS had 65.7 % sensitivity, 94.9 % specificity, 81.2 % positive predictive value and 89.3 % negative predictive value. The SVS's sensitivity increased from 65.7 % to 81.9 % with cycloplegia compared to noncycloplegic SVS results. The sensitivity detection of hyperopia was improved from 4.2 % to 100 % after cycloplegia. Areas under the receiver operator characteristic curve for noncycloplegic SVS and cycloplegic SVS were 0.506 (95 % CI, 0.395 to 0.646, p = 0737) and 0.905 (95 % CI, 0.915 to 0.971, p < 0.001) for hyperopia, respectively. Using the +1.64 D revised cutoff criteria for hyperopia increased sensitivity from 4.2 % to 78 %. CONCLUSION: Noncycloplegic SVS measurements showed relatively high specificity in detecting amblyopia risk factors. The fact that noncycloplegic measurements have a very low sensitivity for hyperopia is an important weakness of the SVS, especially because hyperopia is the most frequently encountered refractive error in very young children. It should be noted that amblyogenic hyperopia may be overlooked by an SVS without cycloplegia.


Assuntos
Ambliopia , Midriáticos , Sensibilidade e Especificidade , Seleção Visual , Humanos , Ambliopia/diagnóstico , Pré-Escolar , Criança , Masculino , Feminino , Fatores de Risco , Midriáticos/administração & dosagem , Seleção Visual/instrumentação , Seleção Visual/métodos , Curva ROC , Erros de Refração/diagnóstico , Guias de Prática Clínica como Assunto , Valor Preditivo dos Testes
9.
Vestn Oftalmol ; 140(1): 32-35, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450464

RESUMO

PURPOSE: This study assesses the effect of pleoptic treatment on the stability of visual fixation in children and adolescents with amblyopia of various degrees. MATERIAL AND METHODS: The effect of the treatment in 35 children (35 eyes) with amblyopia of various degrees was evaluated using the MP-1 Microperimeter. The stability was determined by two criteria - number of fixation point hits in the 2° zone and the width of the field of fixation. Children underwent a standard course of treatment. RESULTS: There was an improvement in the stability of visual fixation after treatment. The number of fixation point hits in the 2° zone increased from 44.8±4.1% to 52.6±3.8%. At the same time, the width of the field of fixation after treatment decreased from 6.5±0.7° to 5.2±0.5°. Visual acuity with correction in children with amblyopia correlates with the number of fixation point hits in the 2° zone (direct high correlation "+0.7") and width of the field of fixation (inverse high correlation "-0.7") both before and after the treatment. CONCLUSION: Stabilization of visual fixation was observed in patients with amblyopia of varying degrees after the pleoptic treatment.


Assuntos
Ambliopia , Criança , Humanos , Adolescente , Ambliopia/diagnóstico , Ambliopia/etiologia , Ambliopia/terapia , Ortóptica , Fixação Ocular , Olho , Acuidade Visual
11.
J Pediatr Ophthalmol Strabismus ; 61(1): e11-e12, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38306235

RESUMO

A 15-year-old boy whose anisometropic amblyopia was effectively treated with glasses was examined. Despite years of stability, his visual acuity decreased from 20/20 to 20/60 with poor glasses compliance. Although amblyopia recurrence is well recognized, this case emphasizes potential late recurrence after prolonged success. Fortunately, he improved to 20/20 after improved compliance. [J Pediatr Ophthalmol Strabismus. 2024;61(1):e11-e12.].


Assuntos
Ambliopia , Anisometropia , Estrabismo , Masculino , Humanos , Adolescente , Ambliopia/diagnóstico , Ambliopia/terapia , Acuidade Visual , Estrabismo/terapia , Anisometropia/complicações , Anisometropia/diagnóstico , Anisometropia/terapia
12.
BMJ Paediatr Open ; 8(1)2024 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-38325900

RESUMO

OBJECTIVE: The aim of this study was to determine the prevalence, causes of ocular disorders and visual impairment among preterm children previously admitted to neonatal intensive care units in Addis Ababa, Ethiopia. METHODS AND ANALYSIS: A prospective screening survey was conducted from February to June 2019 at the paediatric eye clinic of Menelik II Hospital. Children who were preterm at birth and who attended the eye clinic were included in the study. Data on demographic and neonatal characteristics, neonatal and maternal comorbidities and ocular disorders were collected. OR and univariate analysis were used to identify predictors of ocular diseases and visual impairment. RESULTS: There were 222 children included in the study with a mean age at presentation of 2.62 years (range 2.08-6.38 years), mean gestational age 34.11 weeks (range 30-36) weeks and mean birth weight 1941.72 g (range 953-3500 g). Nearly two-thirds had ocular disorders with refractive error (51.8%), strabismus (11.3%) and a history of retinopathy of prematurity (ROP) (7.2%) being more common. One-fourth of the children had visual impairment, and the prevalence of amblyopia was 40.1%. Uncorrected refractive errors, strabismus and ROP were causes for visual impairment. CONCLUSION: Visual impairment and amblyopia are common in Ethiopia. There is a need to develop a screening protocol for ocular disorders for preterm children to enhance early detection and prevention of childhood visual impairment.


Assuntos
Ambliopia , Erros de Refração , Retinopatia da Prematuridade , Estrabismo , Baixa Visão , Humanos , Recém-Nascido , Criança , Pré-Escolar , Lactente , Ambliopia/diagnóstico , Ambliopia/epidemiologia , Prevalência , Estudos Prospectivos , Etiópia/epidemiologia , Erros de Refração/complicações , Erros de Refração/epidemiologia , Estrabismo/epidemiologia , Retinopatia da Prematuridade/epidemiologia , Retinopatia da Prematuridade/diagnóstico
13.
JAMA Ophthalmol ; 142(3): 188-197, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38300546

RESUMO

Importance: Amblyopia can result in permanent vision loss if not properly treated before age 7 years. In 2017, the US Preventive Services Task Force recommended that vision screening should occur at least once in all children aged 3 to 5 years to detect amblyopia. Objective: To understand trends and factors associated with screening, referral, or diagnosis of amblyopia before and after photoscreening expansion across a relatively large health care system in late 2017. Design, Setting, and Participants: This is a retrospective cohort study of electronic health record data from patients with a well child care visit at approximately age 3 years (ages 2.75-3.25 years) in a relatively large, multispecialty group practice in Northern California and linked census data between 2015 and 2022. Data were extracted and analyzed from October 2022 through August 2023. Exposures: Patient sex, race and ethnicity, immunization records, previous well child care visits, and census-level median household income. Main Outcomes and Measures: Vision screening, pediatric ophthalmology referral, or amblyopia diagnosis, compared using adjusted odds ratios (AORs). Results: The study included 2015-2017 data from 23 246 patients aged 3 years with at least 1 well child care visit (11 206 [48.2%] female) compared with 2018-2022 postexpansion data from 34 281 patients (16 517 [48.2%] female). The screening rate increased from 5.7% (424 of 7505) in 2015 to 72.1% (4578 of 6354) in 2022. The referral rate increased from 17.0% (1279 of 7505) in 2015 to 23.6% (1836 of 7792) in 2018. The diagnosis rate was 2.7% (200 of 7505) in 2015, peaked at 3.4% (263 of 7792) in 2018, and decreased to 1.4% (88 of 6354) in 2022. Compared with White patients, patients who were Asian, Black, or Hispanic were less likely to be screened (Asian: AOR, 0.80; 95% CI, 0.72-0.88; Black: AOR, 0.71; 95% CI, 0.53-0.96; Hispanic: AOR, 0.88; 95% CI, 0.80-0.97). Compared with White patients, patients who were Asian or Hispanic were more likely to be referred (Asian: AOR, 1.49; 95% CI, 1.36-1.62; Hispanic: AOR, 1.32; 95% CI, 1.18-1.48) and were more likely to be diagnosed (Asian: AOR, 1.29; 95% CI, 1.07-1.56; Hispanic: AOR, 1.67; 95% CI, 1.33-2.11). Conclusions and Relevance: In this study, increased availability of photoscreeners was associated with an increase in overall rates of vision screening for children aged 3 years in a relatively large health care system. Given that US rates of visual impairment are predicted to increase, additional targeted interventions would be needed to address remaining disparities in amblyopia care along patient- and clinician-level factors.


Assuntos
Ambliopia , Seleção Visual , Humanos , Feminino , Masculino , Ambliopia/diagnóstico , Ambliopia/epidemiologia , Ambliopia/terapia , Estudos Retrospectivos , Etnicidade , Transtornos da Visão
14.
Int Ophthalmol ; 44(1): 84, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363427

RESUMO

INTRODUCTION: With high increase in myopia prevalence, we aimed to assess whether Plusoptix_A09 can be used in myopic children over spectacles to predict visual acuity (VA) and myopic refraction changes. METHODS: Myopic children underwent a complete ophthalmological examination. Plusoptix_A09 was performed over spectacles. VA changes, refraction changes and time since previous glasses prescription, were determined. Age, current or past history of amblyopia, presence of strabismus and self-perception of VA changes were registered. RESULTS: In total, 199 patients were included. Spherical power (SP) and spherical equivalent (SE) measured by Plusoptix_A09 over spectacles predicted both VA changes (p < 0.001) and refraction changes (p < 0.001). Values of SP < - 0.06D or SE < - 0.22D indicated a VA decrease (AUC > 0.9, p < 0.01) for sensitivity and specificity of 85.1%, 82.1% and 82.6%, 83.3%, respectively. Age and ophthalmological comorbidities did not influence Plusoptix_A09 measurements (p > 0.05). Plusoptix_A09 over spectacles was a stronger predictor of VA changes when compared to children's self-perception, either in 4-9-year-old patients (p < 0.001 versus p = 0.628) and in 10-18-year-old children (OR < = 0.066 versus OR = 0.190). A decrease in SP and SE of - 0.10D in Plusoptix_A09 predicted a myopia progression of - 0.04D and - 0.05D, respectively. CONCLUSION/RELEVANCE: This study unveiled new features for the Plusoptix, a worldwide available photoscreener used in amblyopia screening. When Plusoptix is performed in children with their glasses on, it can rapidly predict myopia progression. For each decrease of - 0.10D in Plusoptix, a myopia progression of -0.05D is expected. Moreover, Plusoptix is more reliable than children's self-perception of visual acuity changes, making it a useful tool either in primary care or ophthalmology practice.


Assuntos
Ambliopia , Miopia , Erros de Refração , Seleção Visual , Criança , Humanos , Pré-Escolar , Adolescente , Ambliopia/diagnóstico , Erros de Refração/diagnóstico , Óculos , Reprodutibilidade dos Testes , Miopia/diagnóstico , Miopia/terapia , Refração Ocular
15.
Int Ophthalmol ; 44(1): 86, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363441

RESUMO

INTRODUCTION: Amblyopia is generally a unilateral disorder, defined by at least a difference of two lines of visual acuity between both eyes with the best-corrected visual acuity, a decrease in contrast sensitivity, and a decrease in stereopsis. Pattern electroretinogram (PERG) is a noninvasive technique that provides a retinal biopotential and is a highly sensitive indicator of changes in the macular area. Our aim was to evaluate if there are differences in the retinal response of an amblyopic eye compared with a normal eye (NE). METHODS: We evaluated twenty-four adult volunteers, twelve amblyopes (mean 43.42 ± 12.72 years old), and twelve subjects with NE (mean 35.58 ± 12.85 years old). None of the subjects in the two groups had comorbidities. A complete optometric examination was performed including parameters such as visual acuity (VA) by far and near with ETDRS chart, eye alignment with cover test, and evaluation of retinal cells response with PERG. RESULTS: The refractive error found in the NE group of subjects had a mean of - 0.95 ± 1.65D, while the amblyopic group showed a mean of - 2.03 ± 4.29D. The VA in amblyopic eyes had a mean of 0.38 ± 0.20 logMAR. Analyzing PERG data, we observed significant differences in the P50-N95 amplitudes of the amblyopic group compared with the NE group (p < 0.0001-amblyopic eye vs. NE; p = 0.039-fellow eye vs. NE). DISCUSSION: These findings suggest that amblyopic patients may also present other impairments beyond the visual cortex. PERGs seem to be an important complementary examination in the diagnosis of other impairments in amblyopia.


Assuntos
Ambliopia , Erros de Refração , Adulto , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Ambliopia/diagnóstico , Eletrorretinografia , Acuidade Visual , Retina/diagnóstico por imagem
16.
Eye (Lond) ; 38(8): 1462-1470, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38212403

RESUMO

INTRODUCTION: Retinopathy of prematurity (ROP) is a vision-threatening disease of premature infants. Practice guidelines recommend that all infants screened for ROP receive follow-up eye examinations to screen for ophthalmic complications.1 The purpose of this study was to identify risk factors for the development of strabismus, amblyopia, high refractive error, and cataracts among ROP-screened, non-treated infants. METHODS: Retrospective single-centre study of ROP-screened, non-treated premature infants with ophthalmic follow-up. Clinical variables were screened for association with ocular findings at follow-up. Multivariable logistic regression was used to determine the risk factors associated with ocular findings. RESULTS: 309 patients were seen for follow-up at 0.97 (0.69) [mean (SD)] years after neonatal intensive care unit (NICU) discharge. Strabismus was predicted by occipitofrontal circumference (OFC) z-score at NICU discharge (OR 0.61; 95% CI [0.42, 0.88]; p = 0.008), intraventricular haemorrhage (IVH) grade III or IV (OR 3.18; 95% CI [1.18, 8.54]; p = 0.02), and exclusive formula feeding at NICU discharge (OR 2.20; 95% CI [1.07, 4.53]; p = 0.03). Significant predictors of amblyopia were OFC z-score at discharge (OR 0.55; 95% CI [0.31, 0.96]; p = 0.03) and necrotising enterocolitis (NEC) (OR 6.94; 95% CI [1.38, 35.00]; p = 0.02). NEC was a significant risk factor for high refractive error (OR 7.27; 95% CI [1.39, 37.94]; p = 0.02). CONCLUSIONS: Among premature infants screened but not treated for ROP, severe IVH, NEC, low OFC z-score, and exclusive formula feeding at NICU discharge were risk factors for ocular morbidity. These findings affirm the value of ophthalmic follow-up for all ROP-screened infants, particularly those with the identified risk factors.


Assuntos
Recém-Nascido Prematuro , Retinopatia da Prematuridade , Estrabismo , Humanos , Retinopatia da Prematuridade/diagnóstico , Retinopatia da Prematuridade/epidemiologia , Fatores de Risco , Recém-Nascido , Estudos Retrospectivos , Feminino , Masculino , Prevalência , Estrabismo/diagnóstico , Estrabismo/epidemiologia , Erros de Refração/diagnóstico , Erros de Refração/fisiopatologia , Erros de Refração/epidemiologia , Ambliopia/epidemiologia , Ambliopia/diagnóstico , Ambliopia/etiologia , Catarata/epidemiologia , Catarata/diagnóstico , Triagem Neonatal/métodos , Seguimentos , Idade Gestacional , Lactente
17.
Indian J Ophthalmol ; 72(2): 232-235, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38273685

RESUMO

PURPOSE: To assess macular sensitivity and fixation pattern obtained by microperimetry and ganglion cell complex (GCC) obtained by optical coherence tomography (OCT) in cases with unilateral amblyopia and to compare with control. METHODS: The study was conducted with 30 patients with amblyopia, aged 5-18 years, and 30 control eyes of healthy children in the same age group. Participants underwent full ophthalmological examination. Macular sensitivity, stabilization, and location of fixation values were measured using microperimetry. The GCC values were obtained by OCT. Measurements were compared between amblyopic eyes, fellow eyes, and controls. Any correlation between GCC, macular sensitivity, and fixation was investigated. P < 0.05 was considered statistically significant. RESULTS: The mean age was 10.13 ± 3.49 years in the amblyopia group and 11.53 ± 2.7 years in the control group. Three groups were formed: amblyopic eyes (Group 1, n = 30), fellow eyes (Group 2, n = 30), and control eyes (Group 3, n = 30). The macular sensitivity values were found highest in the control group (P = 0.007). Bivariate contour ellipse area 1, which is the numerical value of fixation stabilization, was measured to be the lowest in the control group (P < 0.0001). In the analysis among the three groups, no significant difference was observed in terms of the GCC (P = 0.229). In the correlation analyses, a significant correlation was detected between macular sensitivity and GCC values in amblyopic eyes. CONCLUSION: In amblyopic eyes, the macular sensitivity was significantly lower and the GCC thickness was found to be in a positive correlation with macular sensitivity.


Assuntos
Ambliopia , Macula Lutea , Criança , Humanos , Adolescente , Ambliopia/diagnóstico , Células Ganglionares da Retina , Acuidade Visual , Tomografia de Coerência Óptica/métodos
18.
Am J Ophthalmol ; 259: 1-6, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37437833

RESUMO

PURPOSE: Our aim was to evaluate whether patients with age-related macular degeneration (AMD) and cooccurrent amblyopia are more likely to have diseases diagnosed on both the ipsilateral and the contralateral side in a large Austrian database. DESIGN: Retrospective cross-sectional study. METHODS: Setting: Institutional practice. PATIENT POPULATION: Medical records of all patients who visited the Department of Ophthalmology of the Medical University of Graz between December 1996 and June 2021 were searched for the co-occurrence of AMD and amblyopia. MAIN OUTCOME MEASURES: Data from patients with AMD diagnosed on 1 eye side were used for further analysis. Spectral-domain optical coherence tomography images were analyzed to confirm the lateral asymmetry of AMD. RESULTS: A total of 327,443 patients were screened for the co-occurrence of AMD and amblyopia. Of them, 8742 patients had AMD diagnosed on 1 eye side and 5051 patients had unilateral amblyopia. In total, 163 patients were found to have AMD diagnosed on 1 side and unilateral amblyopia in combination. Of these, 126 patients had AMD and amblyopia on contralateral sides and 37 had AMD and amblyopia on the ipsilateral side (P < .001). CONCLUSIONS: Less amblyopic patients had AMD diagnosed on the amblyopic eye compared with the nonamblyopic eye. In cases of lateral asymmetry, the nonamblyopic eye is more likely to have the more advanced form of AMD.


Assuntos
Ambliopia , Degeneração Macular , Humanos , Ambliopia/diagnóstico , Acuidade Visual , Estudos Retrospectivos , Estudos Transversais , Degeneração Macular/complicações , Degeneração Macular/diagnóstico , Tomografia de Coerência Óptica
19.
Eur J Ophthalmol ; 34(2): 399-407, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37464746

RESUMO

OBJECTIVE: To evaluate the macular microvascular changes using optical coherence tomographic angiography (OCT-A) in children with unilateral amblyopia and their reversibility during treatment. METHODS: Patients with unilateral strabismic or anisometropic amblyopia or residual amblyopia from early congenital cataract surgery, examined between October 2019 and March 2021, were included. Vessel density and perfusion density in the superficial capillary plexus and area, perimeter and circularity of the foveal avascular zone (FAZ) were analysed using OCT-A in amblyopic eyes, contralateral eyes and control group healthy eyes. Correlation analyses between the microvascular parameters and the visual acuity were performed. In a pilot study on a few patients from the amblyopic cohort, longitudinal follow-up during treatment was also performed. RESULTS: A total of 128 eyes of 64 patients were included: 32 amblyopic eyes compared with 32 contralateral eyes and 64 control eyes. Vessel density and perfusion density in the superficial capillary plexus were significantly lower in amblyopic eyes compared to control eyes in 6 × 6 mm (p < 0.02) and 3 × 3 mm (p < 0.01) scans. Correlation analyses showed a linear decrease in vessel density and perfusion density with decreasing visual acuity. The microvascular changes observed were reversible with the occlusion treatment of amblyopia (p < 0.001). CONCLUSIONS: The study found a decrease in vessel density and perfusion density in the macula of children with unilateral functional amblyopia. These microvascular changes were correlated with visual acuity and appeared to be reversible with treatment of amblyopia. On the whole, OCT-A appears to be a relevant complementary examination when it comes to diagnosing and monitoring functional amblyopia.


Assuntos
Ambliopia , Macula Lutea , Criança , Humanos , Ambliopia/diagnóstico , Ambliopia/terapia , Fóvea Central/irrigação sanguínea , Vasos Retinianos , Tomografia de Coerência Óptica/métodos , Angiofluoresceinografia/métodos , Seguimentos , Projetos Piloto , Estudos Transversais
20.
Eur J Ophthalmol ; 34(1): 281-286, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37081780

RESUMO

Background: Amblyopia is a case where one or less commonly, both eyes have impaired visual performance, even with the best optical correction and no visible disease of the visual system. Objectives: To assess contrast sensitivity tests (CST) and pattern visual evoked potentials (PVEP) results in amblyopic children who have already started occlusion therapy for durations ranging from 6 to 12 months. Methods: This cross-sectional study was conducted on 200 eyes of 50 patients with monocular amblyopia and 50 age and sex matched controls. Both patients and controls underwent ophthalmological assessment, PVEP, and CST. Results: There was no statistically significant difference in the results of P100 latencies of qualitative PVEP in amblyopic eyes compared to non-amblyopic eyes and control eyes, while the qualitative CST showed a highly statistically significant difference, being affected in 98% of amblyopic eyes compared to unaffected eyes (4%) and control eyes (4%). The maximum contrast level and minimal contrast level of quantitative CST were significantly lower in amblyopic eyes compared to non-amblyopic and control eyes. The cutoff value of maximal contrast level at mean frequencies of 2.5 ± 0.9 Hz, and a range of (1.1-4.1) for amblyopic eyes is ≤21 dB, while the cutoff value of minimal contrast level at mean frequencies of 13.4 ± 2.6 Hz, and a range of (6.7-18) for amblyopic eyes is ≤12 dB. Conclusion: Detection of amblyopia by CST is a noninvasive and easy procedure, which represents a promising tool to support the diagnosis of amblyopia.


Assuntos
Ambliopia , Criança , Humanos , Ambliopia/diagnóstico , Ambliopia/terapia , Potenciais Evocados Visuais , Acuidade Visual , Sensibilidades de Contraste , Estudos Transversais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...