Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.030
Filtrar
1.
BMC Pulm Med ; 24(1): 265, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38825688

RESUMO

BACKGROUND: Chronic thromboembolic pulmonary hypertension (CTEPH) is a progressive pulmonary vascular disorder with substantial morbidity and mortality, also a disease underdiagnosed and undertreated. It is potentially curable by pulmonary endarterectomy (PEA) in patients with surgically accessible thrombi. Balloon pulmonary angioplasty (BPA) and targeted medical therapy are options for patients with distal lesions or persistent/recurrent pulmonary hypertension after PEA. There is an urgent need to increase the awareness of CTEPH. Qualified CTEPH centers are still quite limited. Baseline characteristics, management pattern and clinical outcome of CTEPH in China needs to be reported. METHODS AND DESIGN: The CHinese reAl-world study to iNvestigate the manaGEment pattern and outcomes of chronic thromboembolic pulmonary hypertension (CHANGE) study is designed to provide the multimodality treatment pattern and clinical outcomes of CTEPH in China. Consecutive patients who are ≥ 14 year-old and diagnosed with CTEPH are enrolled. The diagnosis of CTEPH is confirmed in right heart catheterization and imaging examinations. The multimodality therapeutic strategy, which consists of PEA, BPA and targeted medical therapy, is made by a multidisciplinary team. The blood sample and tissue from PEA are stored in the central biobank for further research. The patients receive regular follow-up every 3 or 6 months for at least 3 years. The primary outcomes include all-cause mortality and changes in functional and hemodynamic parameters from baseline. The secondary outcomes include the proportion of patients experiencing lung transplantation, the proportion of patients experiencing heart and lung transplantation, and changes in health-related quality of life. Up to 31 December 2023, the study has enrolled 1500 eligible patients from 18 expert centers. CONCLUSIONS: As a real-world study, the CHANGE study is expected to increase our understanding of CTEPH, and to fill the gap between guidelines and the clinical practice in the diagnosis, assessment and treatment of patients with CTEPH. REGISTRATION NUMBER IN CLINICALTRIALS.GOV: NCT05311072.


Assuntos
Angioplastia com Balão , Endarterectomia , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/terapia , China , Embolia Pulmonar/complicações , Embolia Pulmonar/terapia , Doença Crônica , Qualidade de Vida , Resultado do Tratamento , Feminino , Terapia Combinada , Masculino , População do Leste Asiático
2.
Trials ; 25(1): 370, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38851710

RESUMO

BACKGROUND: Endovascular therapy has become established as a first-line therapy in most arterial regions. However, open vascular surgery (endarterectomy) remains the treatment of choice for common femoral artery (CFA) lesions. The aim of this study is to investigate the acute and mid-term results of directional atherectomy plus drug-coated balloon (DCB) in comparison to endarterectomy in treatment of de novo arteriosclerotic CFA lesions. METHODS: This prospective, randomized, multicenter non-inferiority study will enroll 306 participants with symptomatic (Rutherford category 1 to 5) de novo stenosis of the CFA including the bifurcation. Patients eligible for both treatment groups could be included in this 1:1 randomized trial. Primary efficacy endpoint is patency of the target lesion at 12 months defined as restenosis < 50% without the need of clinically driven target lesion revascularization (cdTLR). Primary safety endpoint is a combined endpoint including death, myocardial infarction, major or minor amputation of the target limb, and peri-procedural complications at 30 days. Secondary endpoints include primary patency of the target lesion at 6 and 24 months, secondary patency, cdTLR 6, 12, and 24 months, change in ankle-brachial index, and Rutherford-Becker class at 6, 12, and 24 months. Limb salvage, change in quality of life measured by Walking Impairment Questionnaire, and major adverse events including death, myocardial infarction, and minor or major amputation of the target limb will be determined at 6, 12, 24, and 36 months. DISCUSSION: Endovascular treatment of CFA lesions is still a matter of debate. Few studies compared modern endovascular therapy methods against the so-called gold standard surgical endarterectomy so far. Based on recent positive results, this study aims to confirm non-inferiority of a "leaving nothing behind" endovascular approach combining directional atherectomy and DCB compared to surgical therapy. TRIAL REGISTRATION: ClinicalTrials.gov NCT02517827.


Assuntos
Endarterectomia , Artéria Femoral , Doença Arterial Periférica , Grau de Desobstrução Vascular , Humanos , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Angioplastia com Balão/instrumentação , Aterectomia/efeitos adversos , Aterectomia/métodos , Materiais Revestidos Biocompatíveis , Endarterectomia/efeitos adversos , Endarterectomia/métodos , Estudos de Equivalência como Asunto , Artéria Femoral/cirurgia , Salvamento de Membro , Estudos Multicêntricos como Assunto , Doença Arterial Periférica/terapia , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo , Resultado do Tratamento , Dispositivos de Acesso Vascular
3.
Front Immunol ; 15: 1402250, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38855107

RESUMO

Background: This study aimed to employ plasma proteomics to investigate the molecular changes, pathway alterations, and potential novel biochemical markers associated with balloon pulmonary angioplasty (BPA) in patients with chronic thromboembolic pulmonary hypertension (CTEPH). Methods: Pre- and post-BPA plasma samples from five CTEPH patients in the PRACTICE study were analyzed to identify differentially expressed proteins. Proteomic and bioinformatics analyses were conducted, and the identified proteins were further validated using ELISA assays in a separate cohort of the same study. Correlation and multivariate regression analyses were performed to investigate the associations between these differentially expressed proteins and clinical parameters. Results: Significantly higher serum levels of asialoglycoprotein receptor 2 (ASGR2) were detected in 5 CTEPH patients compared to those in healthy individuals but decreased significantly after successful BPA procedures. The decrease in serum levels of ASGR2 after the completion of BPA procedures was further validated in a separate cohort of 48 patients with CTEPH [0.70 (0.51, 1.11) ng/mL vs. 0.38 (0.27, 0.59) ng/mL, P < 0.001]. Significant associations were found between the pre-BPA ASGR2 level and clinical parameters, including neutrophil percentage (R = 0.285, P < 0.05), platelet (PLT) count (R = 0.386, P < 0.05), and high-density lipoprotein cholesterol (HDL-C) before BPA (R = -0.285, P < 0.05). Significant associations were detected between post-BPA serum ASGR2 levels and lymphocyte percentage (LYM%) (R = 0.306, P < 0.05), neutrophil-to-lymphocyte ratio (R = -0.294, P < 0.05), and pulmonary vascular resistance after BPA (R = -0.35, P < 0.05). Multivariate stepwise regression analysis revealed that pre-BPA ASGR2 levels were associated with HDL-C and PLT count (both P < 0.001), while post-BPA ASGR2 levels were associated with LYM% (P < 0.05). Conclusion: Serum levels of ASGR2 may be a biomarker for the effectiveness of BPA treatment in CTEPH patients. The pre-BPA serum level of ASGR2 in CTEPH patients was associated with HDL-C and the PLT count. The post-BPA serum level of ASGR2 was correlated with the LYM%, which may reflect aspects of immune and inflammatory status.


Assuntos
Angioplastia com Balão , Biomarcadores , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Masculino , Hipertensão Pulmonar/sangue , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Feminino , Biomarcadores/sangue , Pessoa de Meia-Idade , Embolia Pulmonar/sangue , Embolia Pulmonar/terapia , Idoso , Proteômica/métodos , Doença Crônica
4.
Zhonghua Jie He He Hu Xi Za Zhi ; 47(5): 404-418, 2024 May 12.
Artigo em Chinês | MEDLINE | ID: mdl-38706062

RESUMO

Chronic thromboembolic pulmonary hypertension (CTEPH) is classified as group IV pulmonary hypertension, characterized by thrombotic occlusion of the pulmonary arteries leading to vascular stenosis or obstruction, progressive increase in pulmonary vascular resistance and pulmonary arterial pressure, and eventual right heart failure. Unlike other types of pulmonary hypertension, the prognosis of CTEPH can be significantly improved by surgery, vascular intervention, and/or targeted drug therapy. Pulmonary endarterectomy (PEA) is the preferred treatment of choice for CTEPH. However, PEA is an invasive procedure with high operative risks, and is currently only performed in a few centers in China. Balloon pulmonary angioplasty (BPA) is an emerging interventional technique for CTEPH, serving as an alternative for patients who are ineligible for PEA or with residual pulmonary hypertension after PEA. BPA is gaining traction in China, but its widespread adoption is limited due to its complexity, operator skills, and equipment requirements, a lack of standard operating procedures and technical guidance, which limit the further improvement and development of BPA in China. To address this, a multidisciplinary panel of experts was convened to develop the Consensus on the Procedure of Balloon Pulmonary Angioplasty for the Chronic Thromboembolic Pulmonary Hypertension, which fomulates guidelines on BPA procedural qualification, perioperative management, procedural planning, technical approach, and complication prevention, with the aim of providing recommendations and clinical guidance for BPA treatment in CTEPH and standardizing its clinical application in this setting. Summary of recommendations: Recommendation 1: It is recommended that physicians who specialize in pulmonary vascular diseases take the lead in formulating the diagnostic and treatment plans for CTEPH, using a multidisciplinary approach.Recommendation 2: Training in BPA technique is critical; novice operators should undergo standardized operative training with at least 50 procedures under the guidance of experienced physicians before embarking on independent BPA procedures.Recommendation 3: BPA requires catheterization labs, angiography systems, standard vascular interventional devices and consumables, drugs, and emergency equipment.Recommendation 4: Patient selection for BPA should consider cardiac and pulmonary function, coagulation status, and comorbid conditions to determine indications and contraindications, thereby optimizing the timing of the procedure and improving safety.Recommendation 5: In experienced centers, patients deemed likely to benefit from early BPA, based on clinical and imaging features of CTEPH and without elevated D-dimer levels, could bypass standard 3-month anticoagulation therapy.Recommendation 6: BPA is a complex interventional treatment that requires thorough pre-operative assessment and preparation.Recommendation 7: The use of perioperative anticoagulants in BPA requires a comprehensive risk assessment of intraoperative bleeding by the operator for individualized decision making.Recommendation 8: A variety of venous access routes are available for BPA; unless contraindicated, the right femoral vein is usually preferred because of its procedural convenience and reduced radiation exposure.Recommendation 9: For the different types of vascular lesion in CTEPH, treatment of ring-like stenoses, web-like lesions, and subtotal occlusions should be prioritized before addressing complete occlusions and tortuous lesions, in order to reduce complications and improve procedural safety.Recommendation 10: A targeted, incremental balloon dilatation strategy based on vascular lesions is recommended for BPA.Recommendation 11: Intravascular pulmonary artery imaging technologies, such as OCT and IVUS can assist in accurate vessel sizing and confirmation of wire placement in the true vascular lumen. Pressure wires can be used to objectively assess the efficacy of dilatation during BPA.Recommendation 12: Endpoints for BPA treatment should be individually assessed, taking into account improvements in clinical symptoms, hemodynamics, exercise tolerance, and quality of life.Recommendation 13: Post-BPA routine monitoring of vital signs is essential; anticoagulation therapy should be initiated promptly post-procedure in the absence of complications. In cases of intraoperative hemoptysis, postoperative anticoagulation regimen adjustments should be adjusted according to the bleeding severity.Recommendation 14: If reperfusion pulmonary edema occurs during or after BPA, ensure adequate oxygenation, diuresis, and consider non-invasive positive-pressure ventilation if necessary, while severe cases may require early mechanical ventilation assistance or ECMO.Recommendation 15: In cases of intraoperative hemoptysis, temporary balloon occlusion to stop bleeding is recommended, along with protamine to neutralize heparin. Persistent bleeding may warrant the use of gelatin sponges, coil embolization, or covered stent implantation.Recommendation 16: For contrast imaging during BPA, non-ionic, low or iso-osmolar contrast agents are recommended, with hydration status determined by the patient's clinical condition, cardiac and renal function, and intraoperative contrast volume used.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Angioplastia com Balão/métodos , Hipertensão Pulmonar/terapia , Hipertensão Pulmonar/etiologia , Embolia Pulmonar/terapia , Doença Crônica , Artéria Pulmonar/cirurgia , Endarterectomia/métodos , Consenso , China
5.
Methodist Debakey Cardiovasc J ; 20(3): 57-64, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38765209

RESUMO

Chronic thromboembolic pulmonary hypertension is a rare form of pulmonary hypertension in patients who have evidence of chronic thromboembolic occlusion of the pulmonary vasculature. Historically, surgical pulmonary thromboendarterectomy has been the treatment of choice. However, with up to 40% of patients deemed inoperable, balloon pulmonary angioplasty has emerged as an additional treatment strategy. Balloon pulmonary angioplasty is a complementary strategy alongside surgical pulmonary thromboendarterectomy and offers the opportunity for pulmonary revascularization in patients who have more distal disease, higher comorbidities, or residual obstruction following operative intervention. This review examines the history of balloon pulmonary angioplasty, highlights its effectiveness, discusses important complications and risk reduction strategies, and emphasizes the importance of centers forming a multidisciplinary team of providers to manage the complexity of patients with chronic thromboembolic pulmonary hypertension.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Artéria Pulmonar , Embolia Pulmonar , Humanos , Embolia Pulmonar/fisiopatologia , Embolia Pulmonar/terapia , Embolia Pulmonar/cirurgia , Embolia Pulmonar/complicações , Doença Crônica , Resultado do Tratamento , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/terapia , Hipertensão Pulmonar/diagnóstico , Artéria Pulmonar/fisiopatologia , Artéria Pulmonar/cirurgia , Fatores de Risco , Pressão Arterial , Endarterectomia/efeitos adversos
7.
Korean J Radiol ; 25(6): 565-574, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38807338

RESUMO

OBJECTIVE: To evaluate the safety and clinical outcomes of the Passeo-18 Lux drug-coated balloon (DCB) in endovascular revascularization procedures under real-world conditions in a Korean population with atherosclerotic disease of the infrainguinal arteries, including below-the-knee (BTK) arteries. MATERIALS AND METHODS: Eight institutions in the Republic of Korea participated in this prospective, multicenter, single-arm, post-market surveillance study. Two hundred patients with Rutherford class 2-5 peripheral arterial disease and infrainguinal lesions suitable for endovascular treatment were competitively enrolled. Data were collected at baseline, the time of intervention, discharge, and 1-, 6-, 12-, and 24-month follow-up visits. The primary safety endpoint was freedom from major adverse events (MAE) within 6 months (except when limiting the time frame for procedure- or device-related mortality to within 30 days), and the primary effectiveness endpoint was freedom from clinically driven target lesion revascularization (CD-TLR) within 12 months after the procedure. RESULTS: A total of 197 patients with 332 target lesions were analyzed. Two-thirds of the patients had diabetes mellitus, and 41.6% had chronic limb-threatening ischemia. The median target lesion length was 100 mm (interquartile range: 56-133 mm). Of the target lesions, 35.2% were occlusions, and 14.8% were located in the BTK arteries. Rate of freedom from MAE was 97.9% at 6 months, and the rate of freedom from CD-TLR was 95.0% and 92.2% at 12 and 24 months, respectively. Subgroup analysis of 43 patients and 49 target lesions involving the BTK arteries showed rate of freedom from MAE of 92.8% at 6 months and rates of freedom from CD-TLR of 88.8% and 84.4% at 12 and 24 months, respectively. CONCLUSION: The results of the present study, including the BTK subgroup analysis, showed outcomes comparable to those of other DCB studies, confirming the safety and effectiveness of Passeo-18 Lux DCB in the Korean population.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Vigilância de Produtos Comercializados , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/terapia , República da Coreia , Angioplastia com Balão/métodos , Pessoa de Meia-Idade , Resultado do Tratamento , Materiais Revestidos Biocompatíveis , Procedimentos Endovasculares/métodos , Idoso de 80 Anos ou mais
8.
Open Heart ; 11(1)2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38719497

RESUMO

BACKGROUND: The treatment of pulmonary hypertension (PH) has improved rapidly in recent decades. There is increasing evidence to support the role of early intervention and treatment in affecting clinical outcomes in PH. OBJECTIVES: To assess treatment effects before and after the escalation of specific PH treatments using continuous heart monitoring with a Reveal LINQ loop recorder. METHODS: Patients were compared before and after treatment escalation. Treatment escalation was defined as an additional pulmonary arterial hypertension (PAH) drug, pulmonary endarterectomy, percutaneous balloon angioplasty or bilateral lung transplantation. Specifically, changes in heart rate variability (HRV), heart rate (HR) and physical activity were assessed. RESULTS: In this prospective study, 41 patients (27 with PAH and 14 with chronic thromboembolic pulmonary hypertension (CTEPH)) were enrolled. Among them, 15 (36.6%) patients underwent PH treatment escalation. Prior to escalation, patients were monitored for a median of 100 (range: 68-100) days and after therapy escalation for a median duration of 165 (range: 89-308) days. In the escalation group, there was a significant increase in HRV, physical activity indexed by daytime HR and a significant decrease in nighttime HR assessed at baseline and after treatment escalation in both the PAH and CTEPH groups. This was paralleled by significant improvements in WHO functional class, 6-min walking distance and N-terminal pro-b-type natriuretic peptide. CONCLUSIONS: This is the first study to demonstrate an association between specific PH therapies and changes in HRV, HR nighttime and physical activity. This indicates the potential of continuous monitoring in the evaluation of treatment effects in PH.


Assuntos
Frequência Cardíaca , Hipertensão Pulmonar , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Frequência Cardíaca/fisiologia , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/terapia , Resultado do Tratamento , Endarterectomia/métodos , Idoso , Anti-Hipertensivos/uso terapêutico , Fatores de Tempo , Angioplastia com Balão/métodos , Adulto , Transplante de Pulmão , Eletrocardiografia Ambulatorial/métodos , Artéria Pulmonar/fisiopatologia
9.
JACC Cardiovasc Interv ; 17(9): 1134-1144, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38749594

RESUMO

BACKGROUND: Limited comparative data exist on different interventional strategies for endovascular revascularization of complex femoropopliteal interventions. OBJECTIVES: In this study, the authors aimed to compare a stent-avoiding (SA) vs a stent-preferred (SP) strategy, promoting optimal lesion preparation and the use of drug-eluting technologies in both arms. METHODS: Within a prospective, multicenter, pilot study, 120 patients with symptomatic complex femoropopliteal lesions (Rutherford classification 2-4, mean lesion length 187.7 ± 78.3 mm, 79.2% total occlusions) were randomly assigned in a 1:1 fashion to endovascular treatment with either paclitaxel-coated balloons or polymer-coated, paclitaxel-eluting stents. Lesion preparation including the use of devices for plaque modification and/or removal was at the operators' discretion in both treatment arms. RESULTS: In the SA group, lesion preparation was more frequently performed (71.7% SA [43/60] vs 51.7% [31/60] SP; P = 0.038) with a high provisional stenting rate (48.3% [29/60]). At the 12-month follow-up, primary patency was 78.2% (43/55) in the SA group and 78.6% (44/56) in the SP group (P = 1.0; relative risk: 0.995; 95% CI: 0.818-1.210). Freedom from major adverse events was determined in 93.1% (54/58) in the SA group and in 94.9% (56/59) in the SP group (P = 0.717; relative risk: 0.981; 95% CI: 0.895-1.075), with all adverse events attributable to clinically driven target lesion revascularization. CONCLUSIONS: Both endovascular strategies promoting lesion preparation before the use of drug-eluting devices suggest promising efficacy and safety results in complex femoropopliteal procedures with a high proportion of total occlusions through 12 months. Ongoing follow-up will show whether different results emerge over time. (Best Endovascular Strategy for Complex Lesions of the Superficial Femoral Artery [BEST-SFA]; NCT03776799).


Assuntos
Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Stents Farmacológicos , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Projetos Piloto , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Dispositivos de Acesso Vascular , Grau de Desobstrução Vascular
10.
Cardiovasc Intervent Radiol ; 47(6): 730-740, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38816504

RESUMO

PURPOSE: In the present trial, the 24-month safety and effectiveness of the TCD-17187 drug-coated balloon (DCB) for the treatment of atherosclerotic lesions in the superficial femoral artery (SFA) and proximal popliteal artery (PA) were evaluated in Japanese patients. METHODS: This was a prospective, multicenter, core laboratory-adjudicated, single-arm trial. From 2019 to 2020, 121 patients with symptomatic peripheral artery disease were enrolled. The primary effectiveness outcome measure was primary patency. The safety outcome measure was the major adverse event (MAE) rate. RESULTS: Age was 74.5 ± 7.3 years, and diabetes mellitus was present in 67.5%. Lesion length and reference vessel diameter (RVD) were 106.0 ± 52.6 mm and 5.2 ± 0.8 mm, respectively. Chronic total occlusion (CTO) and bilateral calcification rate (Grade 3 and 4 by peripheral arterial calcium scoring system (PACSS)) were 17.5% and 50.8%, respectively. The 24-month primary patency rate by duplex ultrasound was 71.3%, while freedom from clinically driven target lesion revascularization (CD-TLR) was 87.0%. The MAE rate was 13.2% and all events consisted of CD-TLR. There were no instances of device- or procedure-related deaths major amputations throughout the 24 months. Multivariate Cox proportional hazards regression analysis revealed significant differences associated with loss of primary patency in the following characteristics: CTO, restenotic lesion and RVD. CONCLUSION: This trial confirmed the safety and effectiveness of TCD-17187 DCB for atherosclerotic lesions of the SFA and/or proximal PA for up to 24 months. LEVEL OF EVIDENCE: Level 3, Cohort study. CLINICAL TRIAL REGISTRATION: URL: https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr.cgi?function=brows&action=brows&recptno=R000038612&type=summary&language=J:Registration ID: UMIN000034122. Registration Date: September 13, 2018.


Assuntos
Angioplastia com Balão , Materiais Revestidos Biocompatíveis , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Grau de Desobstrução Vascular , Humanos , Masculino , Artéria Poplítea/diagnóstico por imagem , Feminino , Idoso , Artéria Femoral/diagnóstico por imagem , Estudos Prospectivos , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Angioplastia com Balão/métodos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Japão
11.
Medicina (Kaunas) ; 60(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38674214

RESUMO

Background: Treatment options for inoperable chronic thromboembolic pulmonary hypertension (CTEPH) or persistent pulmonary hypertension after pulmonary endarterectomy (PEA) include targeted medical therapy and balloon pulmonary angioplasty (BPA). BPA is an emerging treatment modality that has been reported to improve functional capacity, pulmonary hemodynamics, and right ventricular function. Reports from expert centers are promising, but more data are needed to make the results more generalizable. Materials and Methods: We conducted a prospective analysis of nine consecutive CTEPH patients who underwent balloon pulmonary angioplasty (BPA) sessions at Pauls Stradins Clinical University Hospital in Riga, Latvia between 1 April 2022 and 1 July 2023. We assessed World Health Organization (WHO) functional class, 6 min walk distance (6MWD), blood oxygen saturation (SpO2), brain natriuretic peptide (BNP) level at baseline and 3 months after the first BPA session. For two patients on whom repeated BPA sessions were performed, we additionally assessed cardiac output (CO), pulmonary vascular resistance (PVR), and mean pulmonary artery pressure (mPAP). Results: A total of 12 BPA procedures for nine patients were performed; repeated BPA sessions were performed for two patients. Our results show a reduction in BNP levels and improvement in WHO functional class, 6MWD, and SpO2 after the first BPA session. Improvement in 6MWD was statistically significant. Additionally, an improvement in pulmonary hemodynamic parameters was observed. Conclusions: Our data show that BPA is an effective interventional treatment modality, improving both the pulmonary hemodynamics and functional status. Moreover, BPA is safe and excellently tolerated.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Angioplastia com Balão/métodos , Letônia , Masculino , Hipertensão Pulmonar/terapia , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/cirurgia , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Embolia Pulmonar/complicações , Embolia Pulmonar/terapia , Embolia Pulmonar/fisiopatologia , Doença Crônica , Resultado do Tratamento , Adulto , Resistência Vascular
12.
Arch Dis Child ; 109(6): 497-502, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38627026

RESUMO

BACKGROUND: 3D printing has been used in different medical contexts, although it is underutilised in paediatrics. We present the first use of 3D printing in the management of three paediatric patients with complex renovascular disease. METHODS: Patient-specific 3D models were produced from conventional 2D imaging and manufactured using 3D polyjet printing technology. All three patients had different underlying pathologies, but all underwent multiple endovascular interventions (renal artery balloon angioplasty) prior to 3D printing and subsequent vascular surgery. The models were verified by an expert radiologist and then presented to the multidisciplinary team to aid with surgical planning. RESULTS: Following evaluation of the 3D-printed models, all patients underwent successful uni/bilateral renal auto-transplants and aortic bypass surgery. The 3D models allowed more detailed preoperative discussions and more focused planning of surgical approach, therefore enhancing safer surgical planning. It influenced clinical decision-making and shortened general anaesthetic time. The families and the patients reported that they had a significantly improved understanding of the patient's condition and had more confidence in understanding proposed surgical intervention, thereby contributing to obtaining good-quality informed consent. CONCLUSION: 3D printing has a great potential to improve both surgical safety and decision-making as well as patient understanding in the field of paediatrics and may be considered in wider surgical areas.


Assuntos
Impressão Tridimensional , Humanos , Criança , Masculino , Feminino , Obstrução da Artéria Renal/cirurgia , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/terapia , Modelos Anatômicos , Pré-Escolar , Angioplastia com Balão/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Procedimentos Cirúrgicos Vasculares/instrumentação
13.
Cardiovasc Interv Ther ; 39(3): 293-301, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38632168

RESUMO

This multicenter retrospective study assessed the clinical outcomes of endovascular therapy (EVT) using a drug-coated balloon (DCB) that was larger than the predilatation balloons for femoropopliteal artery lesions. We analyzed 1140 cases with symptomatic peripheral artery disease that underwent EVT with DCB for femoropopliteal lesions between 2017 and 2021. The primary endpoint was procedural failure, defined as a composite of deteriorated dissection and bailout stenting. The secondary endpoints included deteriorated dissection, bailout stenting, restenosis, and target lesion revascularization. We performed propensity score matching to compare the clinical outcomes between EVT with a DCB which was larger than the predilatation balloon (larger DCB) and EVT with a DCB which was not (nonlarger DCB). We assigned 276 cases to the larger DCB group and 864 cases to the nonlarger DCB group. Procedural failure was observed in 75 cases, whereas restenosis occurred in 282 cases during a mean follow-up period of 12.7 ± 9.7 months. Propensity score matching extracted 273 pairs with no intergroup difference in baseline characteristics, except the predilatation balloon size. Procedural failure (9.2% versus 6.1%, P = 0.11), deteriorated dissection and bailout stenting proportion (both P > 0.05), and 1-year rates of freedom from restenosis (82.4% versus 84.1%, P = 0.59) and target lesion revascularization (89.7% versus 90.4%, P = 0.83) showed no significant difference between the larger and nonlarger DCB groups. Irrespective of whether the DCB size was larger than the predilatation balloon, no difference was observed in either procedural or clinical outcomes.


Assuntos
Angioplastia com Balão , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Estudos Retrospectivos , Masculino , Feminino , Humanos , Idoso , Doença Arterial Periférica/terapia , Doença Arterial Periférica/cirurgia , Artéria Poplítea/cirurgia , Angioplastia com Balão/métodos , Materiais Revestidos Biocompatíveis , Resultado do Tratamento , Procedimentos Endovasculares/métodos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Dispositivos de Acesso Vascular
14.
Cardiovasc Interv Ther ; 39(3): 273-283, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38635112

RESUMO

One of the major problems associated with bare nitinol stent implantation is stent fracture, particularly in the popliteal artery. The purpose of this study was to determine whether drug coated balloons (DCB), interwoven stents (IWS), or plain old balloon angioplasty (POBA) would be suitable for use in distal femoropopliteal (FP) long lesions when an Eluvia stent was implanted proximal to a lesion. This was a multi-center retrospective study enrolling patients undergoing concomitant use of Eluvia with DCB, IWS or POBA for symptomatic atherosclerotic femoropopliteal disease (lesion length > 15 cm) [Rutherford category 2-6] between January 2018 and September 2021. 79 patients with 89 femoropopliteal lesions were enrolled in this study. The mean lesion length and the percentage of the popliteal artery involvement was 24.3 ± 6.4 cm vs 24.0 ± 9.0 cm vs 26.6 ± 6.2 cm and 65.8% vs 89.4% vs 67.8% for the Eluvia + DCB, Eluvia + IWS, and Eluvia + POBA groups, respectively. The 1-year Kaplan-Meier estimates of primary patency and freedom from major adverse limb events (MALEs) were 53.3% vs 44.1% vs 24.2% and 62.4% vs 51.0% vs 28.1%, respectively. Eluvia + POBA was associated with a lower rate for 1-year primary patency (HR 2.49; 95% confidence interval (CI): 1.28-4.87; p = 0.007 and HR 2.38; 95% CI: 1.13-5.77; p = 0.04). In SFA long lesions with proximal Eluvia implantation, distal implantations of either a DCB or IWS were comparable, as opposed to POBA alone which generated worse results.


Assuntos
Angioplastia com Balão , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Grau de Desobstrução Vascular , Humanos , Masculino , Estudos Retrospectivos , Artéria Poplítea/cirurgia , Feminino , Doença Arterial Periférica/terapia , Doença Arterial Periférica/cirurgia , Idoso , Angioplastia com Balão/métodos , Stents , Ligas , Pessoa de Meia-Idade , Resultado do Tratamento , Desenho de Prótese , Idoso de 80 Anos ou mais , Materiais Revestidos Biocompatíveis
15.
ACS Appl Bio Mater ; 7(5): 3041-3049, 2024 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-38661721

RESUMO

Drug-coated balloon (DCB) therapy is a promising endovascular treatment for obstructive arterial disease. The goal of DCB therapy is restoration of lumen patency in a stenotic vessel, whereby balloon deployment both mechanically compresses the offending lesion and locally delivers an antiproliferative drug, most commonly paclitaxel (PTX) or derivative compounds, to the arterial wall. Favorable long-term outcomes of DCB therapy thus require predictable and adequate PTX delivery, a process facilitated by coating excipients that promotes rapid drug transfer during the inflation period. While a variety of excipients have been considered in DCB design, there is a lack of understanding about the coating-specific biophysical determinants of essential device function, namely, acute drug transfer. We consider two hydrophilic excipients for PTX delivery, urea (UR) and poly(ethylene glycol) (PEG), and examine how compositional and preparational variables in the balloon surface spray-coating process impact resultant coating microstructure and in turn acute PTX transfer to the arterial wall. Specifically, we use scanning electron image analyses to quantify how coating microstructure is altered by excipient solid content and balloon-to-nozzle spray distance during the coating procedure and correlate obtained microstructural descriptors of coating aggregation to the efficiency of acute PTX transfer in a one-dimensional ex vivo model of DCB deployment. Experimental results suggest that despite the qualitatively different coating surface microstructures and apparent PTX transfer mechanisms exhibited with these excipients, the drug delivery efficiency is generally enhanced by coating aggregation on the balloon surface. We illustrate this microstructure-function relation with a finite element-based computational model of DCB deployment, which along with our experimental findings suggests a general design principle to increase drug delivery efficiency across a broad range of DCB designs.


Assuntos
Materiais Revestidos Biocompatíveis , Interações Hidrofóbicas e Hidrofílicas , Paclitaxel , Paclitaxel/química , Paclitaxel/farmacologia , Paclitaxel/administração & dosagem , Materiais Revestidos Biocompatíveis/química , Teste de Materiais , Polietilenoglicóis/química , Tamanho da Partícula , Humanos , Ureia/química , Angioplastia com Balão , Sistemas de Liberação de Medicamentos , Propriedades de Superfície
16.
Respir Res ; 25(1): 164, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622598

RESUMO

BACKGROUND: Balloon pulmonary angioplasty (BPA) improves the prognosis of chronic thromboembolic pulmonary hypertension (CTEPH). Right ventricle (RV) is an important predictor of prognosis in CTEPH patients. 2D-speckle tracking echocardiography (2D-STE) can evaluate RV function. This study aimed to evaluate the effectiveness of BPA in CTEPH patients and to assess the value of 2D-STE in predicting outcomes of BPA. METHODS: A total of 76 patients with CTEPH underwent 354 BPA sessions from January 2017 to October 2022. Responders were defined as those with mean pulmonary artery pressure (mPAP) ≤ 30 mmHg or those showing ≥ 30% decrease in pulmonary vascular resistance (PVR) after the last BPA session, compared to baseline. Logistic regression analysis was performed to identify predictors of BPA efficacy. RESULTS: BPA resulted in a significant decrease in mPAP (from 50.8 ± 10.4 mmHg to 35.5 ± 11.9 mmHg, p < 0.001), PVR (from 888.7 ± 363.5 dyn·s·cm-5 to 545.5 ± 383.8 dyn·s·cm-5, p < 0.001), and eccentricity index (from 1.3 to 1.1, p < 0.001), and a significant increase in RV free wall longitudinal strain (RVFWLS: from 15.7% to 21.0%, p < 0.001). Significant improvement was also observed in the 6-min walking distance (from 385.5 m to 454.5 m, p < 0.001). After adjusting for confounders, multivariate analysis showed that RVFWLS was the only independent predictor of BPA efficacy. The optimal RVFWLS cutoff value for predicting BPA responders was 12%. CONCLUSIONS: BPA was found to reduce pulmonary artery pressure, reverse RV remodeling, and improve exercise capacity. RVFWLS obtained by 2D-STE was an independent predictor of BPA outcomes. Our study may provide a meaningful reference for interventional therapy of CTEPH.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/terapia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Remodelação Ventricular , Ecocardiografia , Doença Crônica , Artéria Pulmonar/diagnóstico por imagem
17.
Catheter Cardiovasc Interv ; 103(6): 972-981, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38606477

RESUMO

BACKGROUND: Ethylene diamine tetra-acetic acid (EDTA) is a chelating agent used to dissolve calcium deposits but evidence in decalcifying atherosclerotic lesions is limited. AIMS: We assessed the feasibility and efficacy of EDTA delivered via porous balloon to target calcified lesions in cadaveric below-the-knee (BTK) arteries. METHODS: Using porcine carotid arteries, EDTA concentration was measured in the arterial wall and outside the artery at the 0-, 0.5-, 4-, and 24-h circulation after the injection through a porous balloon. In cadaver BTK samples, the proximal and distal anterior tibial artery (ATA) and distal posterior tibial artery (PTA) were studied. EDTA-2Na/H2O or EDTA-3Na/H2O were administrated using a porous balloon, then circulated for 6 h for EDTA-3Na/H2O and 24 h for EDTA-2Na/H2O and EDTA-3Na/H2O. Micro-CT imaging of the artery segments before and after the circulation and cross-sectional analyses were performed to evaluate calcium burden. RESULTS: In the porcine carotid study, EDTA was delivered through a porous balloon present in the arterial wall and was retained there for 24 h. In BTK arteries, cross-sectional analyses of micro-CT revealed a significant decrease in the calcium area in the distal ATA segment under 24-h circulation with EDTA-2Na/H2O and in the distal ATA segment under 24-h circulation with EDTA-3Na/H2O. The proximal ATA segment under 6-h circulation with EDTA-3Na/H2O showed no significant change in any parameters of calcium CONCLUSION: EDTA-3Na/H2O or EDTA-2Na/H2O with longer circulation times resulted in greater calcium reduction in atherosclerotic lesion. EDTA may have a potential therapeutic option for the treatment of atherosclerotic calcified lesions.


Assuntos
Angioplastia com Balão , Ácido Edético , Estudos de Viabilidade , Calcificação Vascular , Animais , Ácido Edético/farmacologia , Angioplastia com Balão/instrumentação , Porosidade , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Cadáver , Artérias da Tíbia/diagnóstico por imagem , Quelantes de Cálcio/farmacologia , Fatores de Tempo , Microtomografia por Raio-X , Humanos , Dispositivos de Acesso Vascular , Desenho de Equipamento , Sus scrofa , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/metabolismo , Placa Aterosclerótica , Suínos
18.
J Biomech ; 166: 112058, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38537368

RESUMO

This work presents the application of a chemo-mechano-biological constitutive model of soft tissues for describing tissue inflammatory response to damage in collagen constituents. The material model is implemented into a nonlinear finite element formulation to follow up a coronary standard balloon angioplasty for one year. Numerical results, compared with available in vivo clinical data, show that the model reproduces the temporal dynamics of vessel remodeling associated with subintimal damage. Such dynamics are bimodular, being characterized by an early tissue resorption and lumen enlargement, followed by late tissue growth and vessel constriction. Applicability of the modeling framework in retrospective studies is demonstrated, and future extension towards prospective applications is discussed.


Assuntos
Angioplastia Coronária com Balão , Angioplastia com Balão , Vasos Coronários , Estudos Retrospectivos , Colágeno , Simulação por Computador
19.
Int Heart J ; 65(2): 230-236, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38479851

RESUMO

This study aimed to compare lower limb events associated with preplanned and finally selected treatment strategies-the validity and usefulness of the physician-chosen strategy were verified.We examined the data of 1003 patients in the registry of multicenter endovascular treatment for superficial femoral and popliteal artery disease study and prospectively enrolled patients who underwent endovascular treatment (EVT) of the femoropopliteal (FP) artery between February 2017 and June 2018 from 67 Japanese institutes. The outcome measures were major adverse limb events (MALE) and target vessel revascularization.The EVT strategies were classified into balloon angioplasty-alone (37.3%), primary stenting (26.7%), and provisional stenting (36.0%) groups. In the initial strategy analysis for the balloon angioplasty-alone, primary stenting, and provisional stenting groups, two-year rates of freedom from MALE (95% confidence interval) were 0.680 (0.620-0.732), 0.754 (0.688-0.808), and 0.798 (0.746-0.840), respectively. Additionally, the rate of MALE was significantly higher among patients in the balloon angioplasty-alone group than among those in the primary or provisional stenting groups in the initial strategy analysis (P = 0.007). Changes in treatment strategy were more frequent in the primary stenting group than in the other groups. Furthermore, the rate of MALE did not significantly differ among the three groups in the final strategy analysis (P = 0.56).Limb outcomes for the final applied strategy did not differ among the three strategies. Additionally, the physician's selection bias was mostly appropriate in the EVT of the FP artery.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Humanos , Artéria Femoral/cirurgia , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/etiologia , Artéria Poplítea/cirurgia , Artéria Poplítea/patologia , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular , Estudos Multicêntricos como Assunto
20.
Hemodial Int ; 28(2): 162-169, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38481062

RESUMO

PURPOSE: To evaluate the efficacy and outcome of the transjugular approach in endovascular recanalization of a thrombosed straight arteriovenous graft (AVG) compared to those of the direct hemodialysis access approach (conventional approach). MATERIALS AND METHODS: We retrospectively assessed patients who underwent aspiration thrombectomy and percutaneous transluminal angioplasty for thrombosed straight AVG performed at a single institution between October 2006 and October 2021. A total of 138 thrombosed AVGs in 83 patients (39 male and 44 females) were divided into the transjugular approach group (Group A) and the conventional approach group (Group B). Technical and clinical success, postintervention primary patency, cumulative patency, and periprocedural complications were compared. RESULTS: There was no statistical difference in demographic data between groups A and B. The technical success rate of group A and B was 96.4% (80/83) and 98.2% 54/55, respectively (p > 0.05). The mean procedure time was 61.4 min (Group A) and 70.5 min (Group B) (p > 0.05). There was no statistically significant difference between the two groups in postintervention primary patency. The cumulative patency of Groups A and B was 911.9 days (range 122-6277) and 1062.3 days (range 72-2302 days), respectively (p > 0.05). One patient in Group B experienced a major graft rupture. Pseudoaneurysm formation at the sheath insertion site occurred in two patients in Group B. No cases of stenosis or thrombosis of the IJV or hematoma at the puncture site were observed in Group A. CONCLUSION: The transjugular approach is as safe and effective as the conventional approach for aspiration thrombectomy and percutaneous transluminal angioplasty of thrombosed straight AVGs.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica , Trombose , Feminino , Humanos , Masculino , Estudos Retrospectivos , Grau de Desobstrução Vascular , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Diálise Renal/métodos , Trombose/etiologia , Trombose/cirurgia , Trombectomia/métodos , Angioplastia/efeitos adversos , Resultado do Tratamento , Oclusão de Enxerto Vascular/cirurgia , Oclusão de Enxerto Vascular/complicações , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...