Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.816
Filtrar
1.
Trials ; 25(1): 370, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38851710

RESUMO

BACKGROUND: Endovascular therapy has become established as a first-line therapy in most arterial regions. However, open vascular surgery (endarterectomy) remains the treatment of choice for common femoral artery (CFA) lesions. The aim of this study is to investigate the acute and mid-term results of directional atherectomy plus drug-coated balloon (DCB) in comparison to endarterectomy in treatment of de novo arteriosclerotic CFA lesions. METHODS: This prospective, randomized, multicenter non-inferiority study will enroll 306 participants with symptomatic (Rutherford category 1 to 5) de novo stenosis of the CFA including the bifurcation. Patients eligible for both treatment groups could be included in this 1:1 randomized trial. Primary efficacy endpoint is patency of the target lesion at 12 months defined as restenosis < 50% without the need of clinically driven target lesion revascularization (cdTLR). Primary safety endpoint is a combined endpoint including death, myocardial infarction, major or minor amputation of the target limb, and peri-procedural complications at 30 days. Secondary endpoints include primary patency of the target lesion at 6 and 24 months, secondary patency, cdTLR 6, 12, and 24 months, change in ankle-brachial index, and Rutherford-Becker class at 6, 12, and 24 months. Limb salvage, change in quality of life measured by Walking Impairment Questionnaire, and major adverse events including death, myocardial infarction, and minor or major amputation of the target limb will be determined at 6, 12, 24, and 36 months. DISCUSSION: Endovascular treatment of CFA lesions is still a matter of debate. Few studies compared modern endovascular therapy methods against the so-called gold standard surgical endarterectomy so far. Based on recent positive results, this study aims to confirm non-inferiority of a "leaving nothing behind" endovascular approach combining directional atherectomy and DCB compared to surgical therapy. TRIAL REGISTRATION: ClinicalTrials.gov NCT02517827.


Assuntos
Endarterectomia , Artéria Femoral , Doença Arterial Periférica , Grau de Desobstrução Vascular , Humanos , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Angioplastia com Balão/instrumentação , Aterectomia/efeitos adversos , Aterectomia/métodos , Materiais Revestidos Biocompatíveis , Endarterectomia/efeitos adversos , Endarterectomia/métodos , Estudos de Equivalência como Asunto , Artéria Femoral/cirurgia , Salvamento de Membro , Estudos Multicêntricos como Assunto , Doença Arterial Periférica/terapia , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo , Resultado do Tratamento , Dispositivos de Acesso Vascular
2.
JACC Cardiovasc Interv ; 17(9): 1134-1144, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38749594

RESUMO

BACKGROUND: Limited comparative data exist on different interventional strategies for endovascular revascularization of complex femoropopliteal interventions. OBJECTIVES: In this study, the authors aimed to compare a stent-avoiding (SA) vs a stent-preferred (SP) strategy, promoting optimal lesion preparation and the use of drug-eluting technologies in both arms. METHODS: Within a prospective, multicenter, pilot study, 120 patients with symptomatic complex femoropopliteal lesions (Rutherford classification 2-4, mean lesion length 187.7 ± 78.3 mm, 79.2% total occlusions) were randomly assigned in a 1:1 fashion to endovascular treatment with either paclitaxel-coated balloons or polymer-coated, paclitaxel-eluting stents. Lesion preparation including the use of devices for plaque modification and/or removal was at the operators' discretion in both treatment arms. RESULTS: In the SA group, lesion preparation was more frequently performed (71.7% SA [43/60] vs 51.7% [31/60] SP; P = 0.038) with a high provisional stenting rate (48.3% [29/60]). At the 12-month follow-up, primary patency was 78.2% (43/55) in the SA group and 78.6% (44/56) in the SP group (P = 1.0; relative risk: 0.995; 95% CI: 0.818-1.210). Freedom from major adverse events was determined in 93.1% (54/58) in the SA group and in 94.9% (56/59) in the SP group (P = 0.717; relative risk: 0.981; 95% CI: 0.895-1.075), with all adverse events attributable to clinically driven target lesion revascularization. CONCLUSIONS: Both endovascular strategies promoting lesion preparation before the use of drug-eluting devices suggest promising efficacy and safety results in complex femoropopliteal procedures with a high proportion of total occlusions through 12 months. Ongoing follow-up will show whether different results emerge over time. (Best Endovascular Strategy for Complex Lesions of the Superficial Femoral Artery [BEST-SFA]; NCT03776799).


Assuntos
Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Stents Farmacológicos , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Projetos Piloto , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Dispositivos de Acesso Vascular , Grau de Desobstrução Vascular
3.
Ann Vasc Surg ; 104: 205-216, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38492725

RESUMO

BACKGROUND: This Bayesian network meta-analysis (NMA) sought to evaluate the efficacy of different endovascular treatments for femoropopliteal artery in-stent restenosis (FP-ISR). METHODS: PubMed, Embase, Cochrane Central Register of Controlled Trials, and Web of science for clinical trials from database inception to March 31, 2023, with no language restrictions to retrieve randomized controlled trials or cohort studies evaluating the impact of any kind of endovascular treatments for FP-ISR. Pair-wise meta-analysis and Bayesian NMA were performed to pool the outcome estimates different endovascular treatments. The primary end points under consideration were primary patency rates at both 6-month and 12-month follow-up. RESULTS: A total of 15 studies with 1,424 patients were ultimately enrolled to be analyzed, 7 types of endovascular treatment were identified for comparison. In terms of primary patency and freedom from target lesion revascularization (TLR) at 6-month and12-month follow-up, the direct meta-analysis findings showed that drug-coated balloons (DCB) and covered stent (CS) are considerably superior to plain old balloon angioplasty (POBA), Excimer laser atherectomy (ELA) + DCB is significantly better than DCB. According to the meta-analysis based on Bayesian theory, during the 6-month and 12-months follow-up, we could not find significant difference between the different treatments in terms of the primary patency and the freedom from TLR, based on the surface values under the cumulative ranking curve (SUCRA), CS was considered the best treatment in terms of primary patency (6 months SUCRA = 85.2; 12 months SUCRA = 78.9) and freedom from TLR (6 months SUCRA = 84.9; 12 months SUCRA = 70.9); directional atherectomy + POBA may lead to higher survival rate at 12 months (SUCRA = 89.1) than others treatments; in addition, both ELA + POBA and ELA + DCB have higher limb salvage than POBA. CONCLUSIONS: The findings of this NMA suggest that CS showed positive encouraging results in primary patency and TLR in FP-ISR at 6 and 12 months. However, due to the potential influence of certain confounding factors, the long-term results necessitate validation through numerous randomized controlled trials.


Assuntos
Procedimentos Endovasculares , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Stents , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Teorema de Bayes , Materiais Revestidos Biocompatíveis , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Artéria Femoral/fisiopatologia , Artéria Femoral/diagnóstico por imagem , Metanálise em Rede , Doença Arterial Periférica/terapia , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
4.
Ann Vasc Surg ; 104: 196-204, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38492729

RESUMO

BACKGROUND: The treatment of atherosclerotic lesions in the popliteal artery is challenging. This study aims to investigate the efficacy and safety of excimer laser ablation (ELA) combined with drug-coated balloon (DCB) for these lesions. METHODS: From June 2019 to December 2021, data of patients who underwent ELA combined with DCB in the popliteal artery were retrospectively reviewed. Demographics, lesion characteristics, periprocedural complications, and follow-up information were analyzed. The primary endpoint was primary patency. Secondary endpoints included major amputation-free survival rate, technical success, bailout stenting, clinically-driven target lesion reintervention, improvement of ankle-brachial index (ABI), and Rutherford class. RESULTS: A total of 61 patients were enrolled. The mean age was 73.4 ± 11.7 years. 20 (32.8%) patients had stenotic lesions, while 41 (67.2%) patients had chronic total occlusions. The mean length of these lesions was 7.3 ± 2.8 cm. Procedure technical success rate was 95.1%. Bailout stent was performed in 3 (4.9%) patients. Intraprocedural distal embolization occurred in 3 (4.9%) patients, while flow limiting dissections occurred in 3 (4.9%) patients. The mean ABI was significantly improved from 0.45 ± 0.13 at baseline to 0.90 ± 0.12 after ELA, 0.88 ± 0.11 at 6 months and 0.85 ± 0.12 at 12 months during the follow-up period. The median follow-up time was 28.2 ± 6.1 months. Reintervention was performed in 5 (8.2%) patients. The 2-year primary patency was 83.5%. CONCLUSIONS: ELA combined with DCB is a safe and effective strategy in the treatment of popliteal artery atherosclerotic lesions with low rates of bail-out stenting and high primary patency.


Assuntos
Angioplastia com Balão , Materiais Revestidos Biocompatíveis , Lasers de Excimer , Doença Arterial Periférica , Artéria Poplítea , Grau de Desobstrução Vascular , Humanos , Masculino , Feminino , Idoso , Artéria Poplítea/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Estudos Retrospectivos , Lasers de Excimer/uso terapêutico , Pessoa de Meia-Idade , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Idoso de 80 Anos ou mais , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Fatores de Tempo , Dispositivos de Acesso Vascular , Resultado do Tratamento , Salvamento de Membro , Fatores de Risco , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Intervalo Livre de Progressão , Amputação Cirúrgica
6.
PLoS One ; 19(3): e0297975, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38551934

RESUMO

BACKGROUND: This study evaluated the long-term effects of percutaneous intervention in children and adolescents with transplant renal artery stenosis (TRAS). METHODS: Twenty patients had significant stenosis (>50%) and underwent percutaneous transluminal angioplasty (PTA/stenting) (TRAS group-intervention); 14 TNS (non-significant group -control) patients did not have significant stenosis (≤50%) and were treated clinically. The combined primary endpoints were death from all causes and late graft failure. The secondary endpoints were serum creatinine (SCr), systolic blood pressure (SBP), and diastolic blood pressure (DBP). RESULTS: No statistically significant difference was found between TRAS-Intervention(N = 20) and TNS groups-Control (N = 14) for these clinical parameters: deaths, 1 (5.0%) vs. 0 (0.0%) (p = 1.000) and graft loss, 4 (20.0%) vs. 2 (14.3%) (p = 1.000). For the secondary endpoints, after 1 month and 1 year the values of SCr, SBP, and DBP were similar between the two groups but not statistically significant. DISCUSSION: In the TRAS group (intervention), the stent implantation was beneficial for treating refractory hypertension and reducing blood pressure (BP) in children and adolescents. Despite the outcomes being similar in the two groups, it can be inferred that the patients in the TRAS group (intervention) would have had a worse outcome without the percutaneous intervention. CONCLUSION: TRAS treatment with stenting can be considered for children and adolescents. Because the sample in the present study comprised of only a specific population, further studies are needed for generalization. TRIAL REGISTRATION: The trial was registered at clinictrials.gov with trial registration number NCT04225338.


Assuntos
Angioplastia com Balão , Transplante de Rim , Obstrução da Artéria Renal , Adolescente , Criança , Humanos , Angioplastia com Balão/efeitos adversos , Constrição Patológica/complicações , Hospitais Públicos , Rim , Transplante de Rim/efeitos adversos , Artéria Renal , Obstrução da Artéria Renal/cirurgia , Obstrução da Artéria Renal/etiologia , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
7.
Hemodial Int ; 28(2): 162-169, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38481062

RESUMO

PURPOSE: To evaluate the efficacy and outcome of the transjugular approach in endovascular recanalization of a thrombosed straight arteriovenous graft (AVG) compared to those of the direct hemodialysis access approach (conventional approach). MATERIALS AND METHODS: We retrospectively assessed patients who underwent aspiration thrombectomy and percutaneous transluminal angioplasty for thrombosed straight AVG performed at a single institution between October 2006 and October 2021. A total of 138 thrombosed AVGs in 83 patients (39 male and 44 females) were divided into the transjugular approach group (Group A) and the conventional approach group (Group B). Technical and clinical success, postintervention primary patency, cumulative patency, and periprocedural complications were compared. RESULTS: There was no statistical difference in demographic data between groups A and B. The technical success rate of group A and B was 96.4% (80/83) and 98.2% 54/55, respectively (p > 0.05). The mean procedure time was 61.4 min (Group A) and 70.5 min (Group B) (p > 0.05). There was no statistically significant difference between the two groups in postintervention primary patency. The cumulative patency of Groups A and B was 911.9 days (range 122-6277) and 1062.3 days (range 72-2302 days), respectively (p > 0.05). One patient in Group B experienced a major graft rupture. Pseudoaneurysm formation at the sheath insertion site occurred in two patients in Group B. No cases of stenosis or thrombosis of the IJV or hematoma at the puncture site were observed in Group A. CONCLUSION: The transjugular approach is as safe and effective as the conventional approach for aspiration thrombectomy and percutaneous transluminal angioplasty of thrombosed straight AVGs.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica , Trombose , Feminino , Humanos , Masculino , Estudos Retrospectivos , Grau de Desobstrução Vascular , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Diálise Renal/métodos , Trombose/etiologia , Trombose/cirurgia , Trombectomia/métodos , Angioplastia/efeitos adversos , Resultado do Tratamento , Oclusão de Enxerto Vascular/cirurgia , Oclusão de Enxerto Vascular/complicações , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos
8.
JACC Cardiovasc Interv ; 17(5): 608-618, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479962

RESUMO

BACKGROUND: Whether intraluminal drug-coated balloon (DCB) angioplasty is superior to subintimal DCB angioplasty regarding femoropopliteal (FP) chronic total occlusion (CTO) outcomes has not been systematically determined. OBJECTIVES: The aim of this study was to compare the 1-year clinical outcomes of intraluminal and subintimal DCB angioplasty for the treatment of patients with symptomatic FP CTO. METHODS: This subanalysis of POPCORN (Prospective Multi-Center Registry of Drug-Coated Balloon for Femoropopliteal Disease) evaluated 469 lesions in 469 symptomatic patients with lower extremity artery disease who presented with FP CTO and underwent DCB treatment. Wire passage (intraluminal vs subintimal) was evaluated using intravascular ultrasound. The outcome measure, 1-year freedom from restenosis, was compared between subintimal and intraluminal DCB angioplasty groups after propensity score matching analysis. The Institutional Review Boards of participating centers approved this study. Informed consent was obtained from the participants or their families. RESULTS: During the median follow-up period of 14.2 months, restenosis occurred in 140 patients. After propensity score matching, the subintimal group had a significantly lower 1-year rate of freedom from restenosis than the intraluminal group (77.0% vs 84.2%, respectively; P = 0.024). Interaction analysis revealed a more marked increased risk for restenosis in the subintimal DCB angioplasty group in patients with severe calcification, low-dose DCB use, or smoking. CONCLUSIONS: The present study revealed that intraluminal DCB angioplasty was superior to subintimal DCB angioplasty for FP CTO treatment, with a significantly better 1-year rate of freedom from restenosis.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Humanos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Doença Arterial Periférica/etiologia , Angioplastia com Balão/efeitos adversos , Materiais Revestidos Biocompatíveis , Grau de Desobstrução Vascular
9.
Vasc Health Risk Manag ; 20: 125-140, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38501043

RESUMO

Background: The prevalence of occlusive lower extremity artery disease (LEAD) is rising worldwide while European epidemiology data are scarce. We report incidence and mortality of LEAD repair in Denmark from 1996 through 2018, stratified on open aorto-iliac, open peripheral, and endovascular repair. Methods: A nationwide cohort study of prospective data from population-based Danish registers covering 1996 to 2018. Comorbidity was assessed by Charlson's Comorbidity Index (CCI). Incidence rate (IR) ratios and mortality rate ratios (MRR) were estimated by multivariable Poisson and Cox regression, respectively. Results: We identified 41,438 unique patients undergoing 46,236 incident first-time LEAD repairs by either aorto-iliac- (n=5213), peripheral surgery (n=18,665) or percutaneous transluminal angioplasty (PTA, n=22,358). From 1996 to 2018, the age- and sex-standardized IR for primary revascularization declined from 71.8 to 50.2 per 100,000 person-years (IRR, 0.70; 95% CI, 0.66-0.75). Following a 2.5-fold IR increase of PTA from 1996 to 2010, all three repair techniques showed a declining trend after 2010. The declining IR was driven by decreasing LEAD repair due to claudication, and by persons aged below 80 years, while the IR increased in persons aged above 80 years (p interaction<0.001). LEAD repair was more frequent in men (IRRfemale vs male, 0.78; 95% CI, 0.77-0.80), which was consistent over calendar time (p interaction=0.41). Crude mortality decreased following open/surgical repair, and increased following PTA, but all three techniques trended towards lower adjusted mortality comparing the start and the end of the study period (MRRaorto-iliac, 0.71; 95% CI, 0.54-0.93 vs MRRperipheral, 0.76; 95% CI, 0.69-0.83 vs MRRPTA, 0.96; 95% CI, 0.86-1.07). Increasing age and CCI, male sex, smoking, and care dependency associated with increased mortality. Conclusion: The incidence rate of LEAD repair decreased in Denmark from 1996 to 2018, especially in persons younger than 80 years, and primarily due to reduced revascularization for claudication. Adjusted mortality rates decreased following open surgery, but seemed unaltered following PTA.


Assuntos
Angioplastia com Balão , Humanos , Masculino , Feminino , Idoso , Estudos de Coortes , Estudos Prospectivos , Incidência , Resultado do Tratamento , Angioplastia com Balão/efeitos adversos , Isquemia , Extremidade Inferior/irrigação sanguínea , Claudicação Intermitente/diagnóstico , Claudicação Intermitente/epidemiologia , Claudicação Intermitente/cirurgia , Comorbidade , Artérias , Dinamarca/epidemiologia , Fatores de Risco
10.
J Vasc Surg ; 79(6): 1315-1325, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38382641

RESUMO

OBJECTIVE: The aim of this study was to investigate the mid-term results of stented-assisted balloon-induced intimal disruption and relamination (STABILISE) in patients with aortic dissection with the implementation of volumetric analysis. METHODS: This was a single-center retrospective analysis of prospectively collected data. From May 2017 to September 2022, 42 patients underwent STABILISE for acute complicated or subacute high-risk aortic dissection. STABILISE was completed with distal extended endovascular aortic repair in 24 patients. A computed tomography scan was performed at baseline, before hospital discharge, and at 1, 3, and 5 years. Perfused total aortic, true lumen, and false lumen volumes were assessed for thoracic, visceral, and aorto-iliac segment. The ratio between false lumen and total volume was named perfusion dissection index (PDI). Complete remodeling was defined as PDI = 0, and positive remodeling as PDI ≤0.1. RESULTS: Technical success was 97.6%. No 30-day deaths, spinal cord injuries, or retrograde dissections were observed. Mean follow-up was 44 ± 19.4 months. Thoracic diameter was lower at last available computed tomography scan (36.7 vs 33.0 mm; P = .01). Aortic growth >5 mm was observed in 9.5% of the patients. Thoracic and visceral aortic complete remodeling were 92.8% and 83.3%, respectively, with no difference between acute and subacute group. Distal extended endovascular aortic repair significantly increased complete remodeling in the aorto-iliac segment, compared with STABILISE alone (69.6% vs 21.4%; P < .001). Freedom from vascular reinterventions at 3 years was 83.1% (95% confidence interval, 71.5%-96.6%). Total PDI ≤0.1 at first postoperative control was a predictor of vascular reinterventions (P < .0001). CONCLUSIONS: STABILISE is a safe and feasible technique associated with high mid-term rates of complete remodeling in the thoracic and visceral aorta. Volumetric analysis allows the quantification of aortic remodeling and represents a predictor of aortic reinterventions.


Assuntos
Dissecção Aórtica , Stents , Humanos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Fatores de Tempo , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Remodelação Vascular , Angiografia por Tomografia Computadorizada , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Valor Preditivo dos Testes , Reoperação , Aortografia , Fatores de Risco
11.
Circ Cardiovasc Interv ; 17(2): e013084, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38348677

RESUMO

BACKGROUND: The treatment of complex infra-inguinal disease with drug-coated balloons (DCBs) is associated with a significant number of patients undergoing provisional stenting to treat a suboptimal result. To determine the potential long-term impact of DCB treatment with provisional bare metal stenting in complex lesions in real-world patients, a post hoc analysis was performed on data from the IN.PACT Global Study (The IN.PACT Global Clinical Study for the Treatment of Comprehensive Superficial Femoral and/or Popliteal Artery Lesions Using the IN.PACT Admiral Drug-Eluting Balloon). Five-year outcomes were compared between participants who were stented after DCB treatment versus those treated with DCB alone. METHODS: The IN.PACT Global Study enrolled 1535 participants with intermittent claudication and/or ischemic rest pain caused by femoropopliteal lesions; 1397 patients were included in this subgroup analysis (353 stented and 1044 nonstented). Effectiveness was assessed as freedom from clinically driven target lesion revascularization through 60 months. The primary safety composite end point was defined as freedom from device- and procedure-related death through 30 days, and freedom from major target limb amputation and clinically driven target vessel revascularization through 60 months. RESULTS: Lesions in the stented group were longer (15.37 versus 10.98 cm; P<0.001) and had more total occlusions (54.7% versus 28.6%; P<0.001) compared with the nonstented group. The 5-year Kaplan-Meier estimated freedom from clinically driven target lesion revascularization was similar between groups (66.8% stented versus 70.0% nonstented group, log-rank P=0.22). The safety composite end point was achieved in 64.5% stented versus 68.2% nonstented participants (log-rank P=0.19) as estimated by the Kaplan-Meier method. No significant difference was observed in the cumulative incidence of major adverse events (49.1% stented versus 45.0% nonstented; log-rank P=0.17), including all-cause death (19.6% stented versus 19.3% nonstented, log-rank P=0.99). CONCLUSIONS: In this real-world study, revascularization of complex femoropopliteal artery lesions with DCB angioplasty alone or DCB followed by provisional bare metal stenting in certain lesions achieved comparable long-term safety and clinical effectiveness. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01609296.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Dispositivos de Acesso Vascular , Humanos , Angioplastia com Balão/efeitos adversos , Materiais Revestidos Biocompatíveis , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/patologia , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Doença Arterial Periférica/etiologia , Artéria Poplítea/diagnóstico por imagem , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Estudos Clínicos como Assunto
12.
Curr Probl Cardiol ; 49(5): 102481, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38401824

RESUMO

Pulmonary endarterectomy (PEA) is the first-line treatment for patients with chronic thromboembolic pulmonary hypertension (CTEPH). However, some patients with CTEPH are considered inoperable, and in the last decade, balloon pulmonary angioplasty (BPA) has emerged as a viable therapeutic option for these patients with prohibitive surgical risk or recurrent pulmonary hypertension following PEA. Numerous international centers have increased their procedural volume of BPA and have reported improvements in pulmonary hemodynamics, patient functional class and right ventricular function. Randomized controlled trials have also demonstrated similar findings. Recent refinements in procedural technique, increased operator experience and advancements in procedural technology have facilitated marked reduction in the risk of complications following BPA. Current guidelines recommend BPA for patients with inoperable CTEPH and persistent pulmonary hypertension following PEA. The pulmonary arterial endothelium plays a vital role in the pathophysiologic development and progression of CTEPH.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Humanos , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Doença Crônica , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Artéria Pulmonar/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto
13.
Ther Adv Respir Dis ; 18: 17534666241232521, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38409856

RESUMO

BACKGROUND: Balloon pulmonary angioplasty (BPA) is typically performed in a sequential manner. OBJECTIVES: This study aimed to determine the lowest frequency of BPA for patients who could not reach treatment goals in a short period. DESIGN: Retrospective cohort. METHODS: We retrospectively enrolled 186 BPA-treated patients diagnosed with chronic thromboembolic pulmonary hypertension. According to the accumulative number of performed BPA sessions or treated pulmonary vessels or the ratio of the number of treated pulmonary vessels/the number of baseline lesions (T/P) prior to the initial occurrence of clinical outcome or censored date, we divided patients into different groups. The principal outcome was clinical worsening. RESULTS: After stratifying patients by the number of performed BPA sessions, most baseline parameters were comparable among groups. During follow-up, 31 (16.7%) of 186 patients experienced clinical worsening. The 6-month cumulative clinical worsening-free survival rates of ⩾2 performed sessions group were significantly higher than that of 1 performed session group. The 12-month cumulative rates of clinical worsening-free survival exhibited a declining pattern in the subsequent sequence: ⩾3, 2, and 1 performed BPA sessions, and this trend persisted when follow-up time exceeded 12 months. The 6-, 12-, and 24-month cumulative clinical worsening-free survival rates were comparable between patients with 3 and ⩾4 performed BPA sessions. Similar results were also observed when stratifying patients by the accumulative number of treated pulmonary vessels (⩽8, 9-16, ⩾17) and T/P (⩽0.789, 0.790-1.263, ⩾1.264). CONCLUSION: To achieve optimal short-term outcomes, patients might need to undergo ⩾2 BPA sessions or have ⩾9 pulmonary vessels treated or have T/P ⩾0.790 within 6 months, and undergo ⩾3 BPA sessions or have ⩾17 pulmonary vessels treated or have T/P ⩾1.264 within 12 months.


The least number of BPA session to reach a favorable outcomeWhy was the study done? Balloon pulmonary angioplasty (BPA) has been recommended for patients with chronic thromboembolic pulmonary hypertension, which can significantly improve patients' hemodynamics. However, BPA is typically performed in a stepwise manner, and the duration from the initial session to the final session could extend over a year. If patients could not quickly undergo adequate number of BPA sessions and reach hemodynamic target due to various reasons, what is the best frequency of BPA for them? What did the researchers do? We retrospectively enrolled 186 BPA-treated patients diagnosed with chronic thromboembolic pulmonary hypertension. According to the accumulative number of BPA sessions, we divided patients into different groups to identify the best frequency of BPA to improve prognosis. What did the researchers find? Patients who received at least two BPA sessions within six months had significantly better prognosis than those with one BPA session. Patients who received at least three BPA sessions within a year had significantly better prognosis than those with two BPA sessions. What do the findings mean? To achieve optimal short-term outcome, patients might need to undergo at least two BPA sessions within six months, and undergo at least three BPA sessions within a year.


Assuntos
Angioplastia com Balão , Embolia Pulmonar , Humanos , Artéria Pulmonar , Estudos Retrospectivos , Doença Crônica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Resultado do Tratamento
14.
Exp Clin Transplant ; 22(Suppl 1): 83-87, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38385380

RESUMO

OBJECTIVES: Portal vein stenosis is a relatively rare complication after liver transplant but has severe consequences. We evaluated the efficacy and longterm results of the endovascular treatment methods for portal vein stenosis. MATERIALS AND METHODS: From October 2011 to October 2022, we treated 22 patients (5 female, 17 male) with portal vein stenosis using endovascular methods. Doppler ultrasonography was used for initial diagnosis, with consideration of flow rate increase over stenosis, absence of flow, or reduced anastomotic segment size (>50%). Angiography served as the gold standard, with a pressure gradient above 5 mm Hg indicating the need for treatment. Technical success criteria were defined as <50% stenosis remaining and/or a pressure gradient <5mm Hg. The transhepatic approach was used for all patients. Balloon angioplasty was initially performed, and stents were reserved for patients in the early postoperative period or those unresponsive to balloon angioplasty. RESULTS: The technical success rate was 100%. Mean age was 27.1 years (SD 22.4; range, 4 months to 63 years). Mean time from transplant to intervention was 317 days (range, 0-3135 days). Angioplasty was successful for 7 patients (13.8%). Of 15 patients who underwent stent placement, 9 (40.9%) were in the early postoperative period; in the other 6 patients (27%), results of angioplasty were not satisfactory, and stents were placed. Within 3 months of transplant, 3 patients died because of other complications. Among patients with stents, 2 required reintervention, resulting in reestablishment of good portal venous flow. During the mean follow-up of 24 months (range, 15 days to 9 years), 19 patients (86%) had portal flows within reference limits. CONCLUSIONS: The endovascular approach is a safe and effective treatment option for management of portal vein stenosis in both adult and pediatric liver transplant recipients in the early or late period.


Assuntos
Angioplastia com Balão , Transplante de Fígado , Adulto , Humanos , Criança , Masculino , Feminino , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Veia Porta/diagnóstico por imagem , Constrição Patológica/etiologia , Resultado do Tratamento , Angioplastia com Balão/efeitos adversos , Stents , Estudos Retrospectivos
15.
J Stroke Cerebrovasc Dis ; 33(5): 107631, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38331010

RESUMO

BACKGROUND: Intracranial artery atherosclerotic stenosis (ICAS) is a major cause of stroke, especially in Asian countries. Current treatment options, including balloon-mounted stent (BMS) and balloon angioplasty (BA), lack sufficient evidence to determine a preferred approach. This systematic review and meta-analysis aimed to compare the efficacy and safety of BMS and BA in treating ICAS. METHODS: Following PRISMA 2020 guidelines, we conducted a comprehensive search in PubMed, Web of Science, and Scopus up to December 1, 2023. Eligible studies compared BMS with BA in patients diagnosed with ICAS. Primary outcomes included the success rate and occurrence of stroke (ischemic or hemorrhagic). Secondary outcomes were perforator occlusion, in-stent thrombosis, death, and restenosis. Statistical analysis was conducted using R software version 4.3.1, employing a random-effects model. RESULTS: Five high-quality studies involving 707 patients (515 males, 192 females) were included. BMS had a significantly higher success rate compared to BA (Risk Ratio [RR]: 1.13; CI: 1.03 to 1.24, p < 0.01; I2 = 14 %). The overall risk for stroke (ischemic and hemorrhagic) was significantly higher in BMS (RR: 2.97; CI: 1.32 to 6.67, p < 0.01; I2 = 0 %). However, no significant difference was found between BMS and BA regarding ischemic stroke (RR: 2.33; CI: 0.80 to 6.74, p = 0.12; I2 = 0 %). Additionally, no significant differences were observed in terms of perforator occlusion, in-stent thrombosis, dissection, minor and major strokes, and mortality rates. BMS was associated with a lower risk of restenosis (RR: 0.31; 95 % CI: 0.12 to 0.83, p = 0.02; I2 = 0 %). CONCLUSION: Our results indicate that BMS might be associated with higher success and lower restenosis rates than BA in the treatment of ICAS but with an increased overall risk of stroke. No significant differences were observed in ischemic stroke, perforator occlusion, in-stent thrombosis, dissection, minor and major strokes, and mortality rates. The choice of treatment should consider these findings, alongside the technical challenges and desired angiographic outcomes. Future randomized controlled trials are necessary to further elucidate these results.


Assuntos
Angioplastia com Balão , AVC Isquêmico , Acidente Vascular Cerebral , Trombose , Masculino , Feminino , Humanos , Constrição Patológica/complicações , Angioplastia com Balão/efeitos adversos , Stents , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/terapia , Acidente Vascular Cerebral/epidemiologia , AVC Isquêmico/diagnóstico , AVC Isquêmico/terapia , AVC Isquêmico/complicações , Trombose/complicações , Resultado do Tratamento , Angioplastia/efeitos adversos
16.
Eur Rev Med Pharmacol Sci ; 28(3): 1015-1026, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38375706

RESUMO

OBJECTIVE: To evaluate the triglyceride-glucose index (TyG index) for predicting in-stent restenosis in patients with iliac artery stenosis after percutaneous intervention with stents. PATIENTS AND METHODS: Subjects with iliac artery stenosis, who underwent an iliac stent intervention and were followed up for at least 2 years were included in the study. Subjects were grouped according to TyG index (Group A, TyG index ≤8.848; Group B 8.849 ≤TyG index ≤9.382 and Group C TyG index ≥9.383). The subject's baseline characteristics, blood parameters, claudication distance, Transatlantic Intersociety Consensus classification, target lesion localization, stent direction, number of stents that were applied, and stent type were noted. Pre- and 1st and 2nd-year post-procedure Rutherford statuses, ankle-brachial index, and stenosis degree were recorded. To calculate the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), Group B and Group C were combined and compared with Group A. RESULTS: In total, 255 subjects were evaluated (female, n=77-30.2%, male, n=178-69.8%). The mean age of the subjects was 66.00±10.00 years (range from 39 to 90 years). The pre-procedure Rutherford measurements were significantly different among the groups (p=0.001). The rates of mild claudication and resting pain in Group A were higher than those in Groups B and C. The rate of moderate claudication in Group C was higher than that in Groups A and B. The rate of severe claudication in Group B was higher than that in Groups A and C. One year after the procedure, there were more asymptomatic cases in Group A than in Groups B and C (p=0.001). The rate of mild claudication in Group C was lower than that in Groups A and B. The rate of moderate claudication in Group C was higher than that in Group A. The rate of severe claudication in Group C was higher than that in Groups A and B. Two years after the procedure, the Rutherford measurements and the rates of mild claudication in Groups A and B were higher than those in Group C. The rate of severe claudication in Group C was higher than that in Groups A and B (p=0.001). One year after the procedure, the computed tomography angiography (CTA) measurements and the rate of full patency in Group A were higher than that in Groups B and C. The rate of 0-50% stenosis in Group B was higher than that in Groups A and C. The rate of 50-70% stenosis in Group C was higher than that in Group A. Two years after the procedure, the CTA measurements and the rates of 70-99% stenosis and 100% occlusion in Group C were higher than those in Groups A and B. The TyG index has high specificity and NPV. However, specificity and PPV levels were found to be quite low. CONCLUSIONS: The TyG index was found to be an easy-to-use marker for predicting in-stent restenosis in patients with iliac artery stenosis after percutaneous intervention with stents.


Assuntos
Angioplastia com Balão , Reestenose Coronária , Doença Arterial Periférica , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Constrição Patológica/etiologia , Glucose , Artéria Ilíaca/diagnóstico por imagem , Reestenose Coronária/etiologia , Angioplastia com Balão/efeitos adversos , Resultado do Tratamento , Grau de Desobstrução Vascular , Claudicação Intermitente/diagnóstico , Claudicação Intermitente/terapia , Claudicação Intermitente/etiologia , Stents/efeitos adversos
17.
Cardiovasc Revasc Med ; 63: 54-58, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38245433

RESUMO

OBJECTIVE: To evaluate the safety and effectiveness of drug-coated balloon angioplasty (DCB) in isolated popliteal lesions. BACKGROUND: The benefit of using DCB in femoropopliteal arteries including the proximal popliteal artery has been demonstrated, but has not yet been evaluated for isolated popliteal lesions. METHODS: This retrospective, single-center study includes patients requiring treatment with DCB of isolated popliteal lesions. Two cohorts matched (Plain old balloon angioplasty (POBA) versus DCB) by their baseline and lesion characteristics were compared. Lesions receiving bail-out stents were excluded. Primary endpoint was the 1-year target lesion revascularization (TLR) rate. Secondary endpoints included the procedural success and complication rate, primary patency, changes in Rutherford-Becker class (RBC) and ankle-brachial index (ABI). RESULTS: One hundred and seven patients were included in this study. More than one third of the patients had critical limb threatening ischaemia (CLTI) (35 % (POBA) versus 40.4 % (DCB), p = 0.354. The technical success rate of the procedure was 85.1 % (n = 40/47) in the DCB group and 83.3 % (n = 60) in the POBA group (p = 0.510). There were three complications in the POBA group (5.0 %) but none in the DCB group (p = 0.172). After 12 months, in the entire cohort 14 patients (13.1 %) had to undergo a TLR. The TLR-free survival was 81.7 % in the POBA and 93.6 % in the DCB group (p = 0.060). Primary patency rates after POBA and DCB were 65.1 % and 87.5 % at 6 months (p = 0.024), respectively. At 12 months, the patency rates were 71.7 % and 85.1 % (p = 0.076), respectively. For both treatment arms, there was a significant improvement in ABI and RBC compared to baseline. Four patients from the DCB group and two from the POBA group received a minor amputation (p = 0.232). One patient in the DCB group died within 12 months. CONCLUSION: After one year the use of DCB is by trend more effective for the treatment of isolated popliteal stenosis compared to POBA. A larger scale prospective study is mandatory.


Assuntos
Angioplastia com Balão , Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Paclitaxel , Doença Arterial Periférica , Artéria Poplítea , Grau de Desobstrução Vascular , Humanos , Artéria Poplítea/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Masculino , Estudos Retrospectivos , Paclitaxel/administração & dosagem , Paclitaxel/efeitos adversos , Feminino , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Idoso , Doença Arterial Periférica/terapia , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Fatores de Tempo , Pessoa de Meia-Idade , Fatores de Risco , Idoso de 80 Anos ou mais , Resultado do Tratamento , Salvamento de Membro , Dispositivos de Acesso Vascular , Amputação Cirúrgica
18.
Cardiovasc Revasc Med ; 63: 43-51, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38267286

RESUMO

OBJECTIVES: The highest rate of embolization during carotid artery stenting occurs during post-dilation. We evaluated the ability of the Paladin system (Contego Medical, Raleigh, NC), a novel PTA balloon with an integrated 40-É¥m pore filter, to collect microemboli that may pass into the cerebral circulation when used during post-dilation. METHODS: 25 symptomatic patients underwent transradial CAS using the Paladin system in conjunction with the Roadsaver (Terumo Corporation, Tokyo, Japan) micromesh stent. No additional embolic protection was used. The Paladin filters were collected following the procedure and preserved in formalin for histological analysis. The contents were evaluated for particle count and size. Subjects were followed for 30 days and evaluated for major cardiac adverse events (death, stroke and MI). Secondary endpoints included procedure success, device success, access site complications according to EASY score classification, major vascular or ischemic complications at follow up and in-stent restenosis rate evaluated with duplex ultrasound. RESULTS: Mean age of patients was 68,5 years. Type 2 aortic arch was present in 77 % of patients and type 1 and type 3 in 12 % and 11 % of patients respectively. Procedural and device success was obtained in all cases without complications. The 30-day MAE rate was 0 %. Twenty-three filters underwent histological analysis. Microscopic debris was present in 100 % of filters, and 75 % of particles were less than 100É¥m in size. The mean number of particles per filter was 3352 ± 1567 (IQR 4300-2343), and the mean number of particles between 40-100É¥m per filter was 2499 ± 1240 (IQR 3227-1575). CONCLUSION: CAS through radial approach can be safely and effectively performed using the IEP technology Paladin device and double-layer micromesh Roadsaver stent. This strategy can simplify the procedure and decrease peri-procedural complications and procedural time.


Assuntos
Angioplastia com Balão , Estenose das Carótidas , Dispositivos de Proteção Embólica , Desenho de Prótese , Artéria Radial , Stents , Humanos , Idoso , Masculino , Feminino , Resultado do Tratamento , Pessoa de Meia-Idade , Fatores de Tempo , Artéria Radial/diagnóstico por imagem , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Estenose das Carótidas/terapia , Estenose das Carótidas/diagnóstico por imagem , Fatores de Risco , Porosidade , Embolia Intracraniana/prevenção & controle , Embolia Intracraniana/etiologia , Idoso de 80 Anos ou mais
19.
J Chin Med Assoc ; 87(3): 273-279, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38252515

RESUMO

BACKGROUND: The long-term outcome on patients with chronic thromboembolic pulmonary hypertension (CTEPH) has not been ideal after standard medical treatment. However, good outcome for patients with CTEPH after interventions such as pulmonary endarterectomy (PEA) and balloon pulmonary angioplasty (BPA) has been reported recently. The aim of this study was to evaluate the impact of PEA or BPA on long-term outcomes for CTEPH patients in Han-Chinese population. METHODS: This was a multicenter, prospective case-control study. Patients with CTEPH were enrolled between January, 2018 and March, 2020. They were divided into two groups, including intervention (PEA or BPA) and conservative groups. The followed-up period was 26 months after treatment. The endpoints were all-cause mortality and CTEPH mortality. RESULTS: A total of 129 patients were enrolled and assigned to receive PEA/BPA (N = 73), or conservative therapy (N = 56). Overall, the 26-month survival rate of all-cause mortality was significantly higher in intervention group compared to that in conservative group (95.89% vs 80.36%; log-rank p = 0.0164). The similar trend was observed in the 26-month survival rate of CTEPH mortality (97.26% vs 85.71%; log-rank p = 0.0355). Regarding Cox proportional-hazard regression analysis, the hazard ratios (HRs) on patients with CTEPH receiving intervention in the outcome of all-cause mortality and CTEPH mortality were statistically significant (HR = 0.07 and p = 0.0141 in all-cause mortality; HR = 0.11 and p = 0.0461 in CTEPH mortality). CONCLUSION: This multicenter prospective case-control study demonstrated that intervention such as PEA and BPA increased the long-term survival rate for patient with CTEPH significantly. Intervention was an independent factor in long-term outcome for patients with CTEPH, including all-cause mortality and CTEPH mortality.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/cirurgia , Embolia Pulmonar/complicações , Embolia Pulmonar/cirurgia , Estudos de Casos e Controles , Doença Crônica , Angioplastia com Balão/efeitos adversos , Endarterectomia/efeitos adversos , Artéria Pulmonar/cirurgia
20.
Clin J Am Soc Nephrol ; 19(3): 336-344, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38191561

RESUMO

BACKGROUND: The aim of this study was to evaluate the efficacy and safety of paclitaxel-coated balloons (AcoArt Orchid) in treating dysfunctional arteriovenous fistulae. METHODS: The drug-eluting balloon for arteriovenous (AV) fistula in China trial was a prospective, multicenter, randomized controlled study. Patients who had ≥50% venous stenosis of the AV fistula and symptoms indicating significant hemodynamic changes were included. After successful predilation with a high-pressure balloon (residual stenosis ≤30%), patients were randomized 1:1 to either a paclitaxel-coated balloon or an uncoated control balloon. The primary efficacy outcome was assessed at 6 months, and safety assessment was conducted within 30 days of the procedure. The 12-month results were also analyzed. RESULTS: The study included 244 patients, equally distributed between the two groups. The primary target lesion patency was 91% (106/116) for the drug-coated balloon (DCB) group and 67% (79/118) for the plain balloon catheter group, representing a difference of 24.63% (95% confidence interval, 14.68 to 34.58; P < 0.001). The secondary efficacy end point was primary target lesion patency at 12 months, which was 66% (74/112) for the DCB group and 46% (52/112) for the plain balloon catheter group (95% confidence interval, 6.57 to 32.08; P = 0.004). The mean number of reinterventions per patient to maintain target lesion patency during the 12 months after the index procedure was 0.39 (48/122) in the DCB group and 0.77 (94/122) in the plain balloon catheter group ( P = 0.001). The primary safety end point did not differ between groups ( P = 0.25). CONCLUSIONS: AcoArt Orchid DCB showed better primary patency rates compared with plain balloon angioplasty for treating stenotic lesions in dysfunctional hemodialysis AV fistulae at 6 and 12 months. It required fewer repeated interventions and had comparable safety in 1 year. CLINICAL TRIAL REGISTRY NAME AND REGISTRATION NUMBER: AcoArt III/Arterio-venous Fistula in China, NCT03366727 .


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica , Fístula , Humanos , Grau de Desobstrução Vascular , Constrição Patológica/terapia , Estudos Prospectivos , Resultado do Tratamento , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Materiais Revestidos Biocompatíveis , Fatores de Tempo , Angioplastia com Balão/efeitos adversos , Diálise Renal , Paclitaxel
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...