Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Drug Res (Stuttg) ; 70(1): 12-22, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31539916

RESUMO

Bepotastine besilate (here after referred to as BTST), chemically known as ({d(S)4[4[(4chlorophenyl) (2pyridyl) methoxy] piperidino} butyric acid monobenzene sulphonate), is a second-generation antihistamine drug. To the best of our knowledge, no studies concerning the isolation or identification of process-related impurities have been reported so far. The current study reports the development and validation of a stability-indicating RP-HPLC method for the separation and identification of 5 potential impurities in bepotastine besilate. In this experiment, the structures of 3 process-related impurities were found to be new compounds. They were characterized and confirmed by NMR and MS spectroscopy analyses. These 3 new compounds were proposed to be (S)-4-[(phenyl)-2-pyridinylmethoxy]-1-piperidinebutanoic acid,(Imp-A); 4-[(S)-(4-chlorophenyl)-2-pyridinylmethoxy]-1- piperidinebutyric acid, N-oxide (Imp-B) and (S)-4-[(4- chlorophenyl)-2-pyridinylmethoxy]-1-piperidylethane (Imp-C). In addition, an efficient optimized chromatographic method was performed on a Shimadzu Inertsil C8-3 column (150 mm×4.6 mm, 3 µm) to separate and quantify these 5 impurities. It was using 15 mmol ammonium formate buffer in water (pH adjusted to 3.8 with formic acid) and acetonitrile as the mobile phase in gradient mode. The method was developed to separate and quantify these 5 impurities obtained in the range of 0.05-0.75 µg/mL. It was validated and proven to be selective, accurate and precise and suitable. It is the first publication of identification and characterization data of the 3 new compounds. It is also the first effective HPLC method for separation and quantification of all of process-related impurities in bepotastine besilate.


Assuntos
Antialérgicos/análise , Composição de Medicamentos/normas , Contaminação de Medicamentos/prevenção & controle , Piperidinas/análise , Piridinas/análise , Antialérgicos/normas , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Limite de Detecção , Espectroscopia de Ressonância Magnética , Piperidinas/normas , Piridinas/normas , Espectrometria de Massas em Tandem
2.
J Investig Allergol Clin Immunol ; 25(2): 94-106, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25997302

RESUMO

Allergic conjunctivitis (AC) is an inflammatory disease of the conjunctiva caused mainly by an IgE-mediated mechanism. It is the most common type of ocular allergy. Despite being the most benign form of conjunctivitis, AC has a considerable effect on patient quality of life, reduces work productivity, and increases health care costs. No consensus has been reached on its classification, diagnosis, or treatment. Consequently, the literature provides little information on its natural history, epidemiological data are scarce, and it is often difficult to ascertain its true morbidity. The main objective of the Consensus Document on Allergic Conjunctivitis (Documento dE Consenso sobre Conjuntivitis Alérgica [DECA]), which was drafted by an expert panel from the Spanish Society of Allergology and Spanish Society of Ophthalmology, was to reach agreement on basic criteria that could prove useful for both specialists and primary care physicians and facilitate the diagnosis, classification, and treatment of AC. This document is the first of its kind to describe and analyze aspects of AC that could make it possible to control symptoms.


Assuntos
Alergia e Imunologia/normas , Antialérgicos/uso terapêutico , Conjuntivite Alérgica/terapia , Imunoterapia/métodos , Antialérgicos/normas , Conjuntivite Alérgica/classificação , Conjuntivite Alérgica/diagnóstico , Conjuntivite Alérgica/imunologia , Consenso , Diagnóstico Diferencial , Humanos , Imunoterapia/normas , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Resultado do Tratamento
3.
Arch Pharm Res ; 30(10): 1350-7, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18038915

RESUMO

An immunoglobulin (IgG) preparation with micro-amount of histamine fixed on the active protein fraction has been used to increase the resistance to allergic reactions. However, excessive histamine may cause hypo- or hypertension, headache, or anaphylactic shock and so the histamine content of the drug is strictly controlled by a regulation: 0.15 microg of histamine dihydrochloride is allowed for 12 mg of immunoglobulin. In this study, a liquid chromatographic method to determine micro-amount of histamine in the pharmaceutical was developed and validated. This method include a sample cleanup by a solid phase extraction (SPE) using a polystyrene-divinyl benzene (PS-DVB) polymeric sorbent and high-performance liquid chromatography after precolumn fluorescent labeling of the histamine with o-phthaldialdehyde. The drug sample was loaded to the SPE cartridge after adjusting to pH 9.5. After successive washings of the cartridge with water and 30% aqueous methanol, histamine was then eluted with 100 mM sodium acetate (pH 9.5)-methanol (20:80, v/v). An aliquot from the eluate was labeled with o-phthaldialdehyde-mercaptoethanol (OPA-ME) for fluorescence detection at the excitation maximum of 340 nm and emission maximum of 450 nm. HPLC analysis was performed on a phenyl-hexyl column with an acetonitrile-phosphate buffer (pH 6.8; 50 microM) (35:65, v/v) as the mobile phase. The retention times of histamine and 3-methylhistamine (IS) were approximately 7.2 and 9.5 min, respectively. The quantitation range was between 0.01-0.2 mg/mL of histamine showing good linearity (r=0.9996). This analytical method would provide a potential mean for the strict control of histamine content in the pharmaceutical product.


Assuntos
Antialérgicos/química , Cromatografia Líquida de Alta Pressão/métodos , Histamina/análise , Imunoglobulina G/química , Extração em Fase Sólida , Acetonitrilas/química , Antialérgicos/normas , Soluções Tampão , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Concentração de Íons de Hidrogênio , Indicadores e Reagentes/química , Resinas de Troca Iônica/química , Mercaptoetanol/química , Metanol/química , Metilistaminas/análise , Poliestirenos/química , Controle de Qualidade , Reprodutibilidade dos Testes , Acetato de Sódio/química , Solventes/química , Espectrometria de Fluorescência , o-Ftalaldeído/química
4.
Expert Opin Investig Drugs ; 16(9): 1327-44, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17714020

RESUMO

This perspective is the second in a series discussing drugs dropped from development in 2006, with a focus on pulmonary-allergy, dermatological, gastrointestinal and arthritis drugs. A survey of discontinued drugs from 2006 is provided, based on data from the Pharmaprojects database, along with an analysis of biology, mechanisms of action and economic considerations in developing new drugs.


Assuntos
Antialérgicos/normas , Antirreumáticos/normas , Fármacos Dermatológicos/normas , Fármacos Gastrointestinais/normas , Medicamentos para o Sistema Respiratório/normas , Animais , Antialérgicos/efeitos adversos , Antirreumáticos/efeitos adversos , Fármacos Dermatológicos/efeitos adversos , Aprovação de Drogas/métodos , Indústria Farmacêutica/métodos , Indústria Farmacêutica/normas , Drogas em Investigação/efeitos adversos , Drogas em Investigação/normas , Fármacos Gastrointestinais/efeitos adversos , Humanos , Medicamentos para o Sistema Respiratório/efeitos adversos
5.
Dev Biol (Basel) ; 122: 145-52, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16375259

RESUMO

Allergen vaccines are complex extracts of natural products, and are used for the diagnosis and treatment of allergic diseases. In the U.S., 19 allergen extracts have been standardized. For these vaccines, the potency is estimated by the skin test responses of highly allergic individuals, and surrogate in vitro tests are established for lot release and quality control. The surrogate tests differ for different extracts. National reference standards to which manufactured lots are compared are maintained at FDA/CBER. Allergen standardization has facilitated the establishment of data-driven release limits.


Assuntos
Alérgenos/análise , Antialérgicos/normas , Bioensaio/normas , Misturas Complexas/normas , Vacinas/normas , Antialérgicos/análise , Misturas Complexas/análise , Hipersensibilidade/diagnóstico , Hipersensibilidade/terapia , Padrões de Referência , Vacinas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...