Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 48(1): 78-84, 2008 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-18562149

RESUMO

Photodegradation of seratrodast ([+/-]-7-(3,5,6-trimethyl-1,4-benzoquinone-2-yl)-7-phenyl-heptanoic acid, SD), a p-benzoquinone anti-asthmatic drug, has been investigated in different solutions. HPLC analysis showed that SD was degradated under UV irradiation at 254 nm to afford three major products (SD1, SD2 and SD3) in methanol and in acetonitrile/H2O solutions, while only two of them (SD2 and SD3) could be detected in acetonitrile solution. Furthermore, SD1 was unstable even when the samples were protected from light, so the acetylated SD1 (Ace-SD1) together with SD2 and SD3 were isolated by semi-preparative reversed-phase HPLC. The structures were elucidated as 6-(2,5-diacetoxy-3,4,6-trimethyl-phenyl)-7-phenyl-hept-6-enoic acid (Ace-SD1), 7-phenyl-6-(2,4,5-trimethyl-3,6-dioxo-cyclohexa-1,4-dienyl)-hept-6-enoic acid (SD2) and 5-(5-hydroxy-4,6,7-trimethyl-2-phenyl-benzofuran-3-yl)-pentanoic acid (SD3) based on the spectral data of MS, UV spectrum, IR spectrum and NMR spectrum. Meanwhile, a possible route for the formation of these photoproducts was proposed, which might explain the generation procedure of SD1, SD2 and SD3 during UV irradiation.


Assuntos
Antiasmáticos/química , Antiasmáticos/efeitos da radiação , Benzoquinonas/química , Benzoquinonas/efeitos da radiação , Ácidos Heptanoicos/química , Ácidos Heptanoicos/efeitos da radiação , Fotólise , Acetonitrilas/química , Cromatografia Líquida de Alta Pressão , Espectroscopia de Ressonância Magnética , Espectrometria de Massas , Metanol/química , Estrutura Molecular , Soluções/química , Espectrofotometria Infravermelho , Espectrofotometria Ultravioleta , Raios Ultravioleta , Água/química
2.
J Chromatogr B Biomed Sci Appl ; 713(2): 409-14, 1998 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-9746257

RESUMO

MK-0476 (montelukast sodium) is a potent and selective cysteinyl leukotriene receptor antagonist that is being investigated in the treatment of asthma. A simple and sensitive method for the determination of MK-0476 in human plasma was developed using column-switching high-performance liquid chromatography (HPLC) with fluorescence detection. A plasma sample was injected directly onto the HPLC system consisting of a pre-column (Capcell pak MF) and an analytical column (Capcell pak C18) which were connected with a six-port switching valve. The column eluate was monitored with a fluorescence detector (excitation at 350 nm; emission at 400 nm). The calibration curve was linear in a concentration range of 1-500 ng ml(-1) for MK-0476 in human plasma. The intra-day coefficients of variation of all concentrations within the range was less than 9.2%, and the intra-day accuracy values were between 97.2 and 114.6%. This method was used to measure the plasma concentration of MK-0476 following oral administration of the drug in humans.


Assuntos
Acetatos/sangue , Antiasmáticos/sangue , Antagonistas de Leucotrienos/sangue , Quinolinas/sangue , Acetatos/química , Acetatos/farmacologia , Acetatos/efeitos da radiação , Administração Oral , Antiasmáticos/química , Antiasmáticos/farmacologia , Antiasmáticos/efeitos da radiação , Cromatografia Líquida de Alta Pressão , Ciclopropanos , Humanos , Antagonistas de Leucotrienos/química , Antagonistas de Leucotrienos/farmacologia , Antagonistas de Leucotrienos/efeitos da radiação , Masculino , Quinolinas/química , Quinolinas/farmacologia , Quinolinas/efeitos da radiação , Sensibilidade e Especificidade , Espectrometria de Fluorescência , Estereoisomerismo , Sulfetos , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...