RESUMO
OBJECTIVE: The aim of our study was to compare the traditional radial artery, distal radial artery, and transfemoral artery, which are vascular access sites for coronary angiography, in terms of pain level using the visual analog scale. METHODS: Between April 2021 and May 2022, consecutive patients from three centers were included in our study. A total of 540 patients, 180 from each of the traditional radial artery, distal radial artery , and transfemoral artery groups, were included. The visual analog scale was applied to the patients as soon as they were taken to bed. RESULTS: When the visual analog scale was compared between the groups, it was found to be significantly different (transfemoral artery: 2.7±1.6, traditional radial artery: 3.9±1.9, and distal radial artery: 4.9±2.1, respectively, p<0.001). When the patients were classified as mild, moderate, and severe based on the visual analog scale score, a significant difference was found between the groups in terms of body mass index, process time, access time, and number of punctures (p<0.001). Based on the receiver operating characteristic analysis, body mass index>29.8 kg/m2 predicted severe pain with 72.5% sensitivity and 73.2% specificity [(area under the curve: 0.770, 95%CI: 0.724-0.815, p<0.0001)]. CONCLUSION: In our study, we found that the femoral approach caused less access site pain and a high body mass index predicts severe pain.
Assuntos
Cateterismo Cardíaco , Artéria Radial , Humanos , Angiografia Coronária , Artéria Radial/diagnóstico por imagem , Fatores de Tempo , Dor/etiologia , Resultado do TratamentoRESUMO
Transradial access is widely used in cardiological adult interventions and less in pediatrics. In recent years, this access has become more popular in the neuroradiological community in adult patients since it has fewer complications and is more comfortable for the patient after the procedure. We present a single-center case series of 52 transradial access neurointerventions (43 angiographies and 9 therapeutic procedures) in pediatric patients, with a failure of 4 cases (7.7%) in which we could not puncture the artery, crossing over to transfemoral access. Since in five cases we did angiography followed by therapeutic intervention, thus doing only one puncture access for both procedures, then our access failure rate was 10.6%. The 34 successful transradial access solely angiographies had a median radiation exposure of 887â mGy (interquartile range 628-1352), median fluoroscopy time of 9.5â min (interquartile range 7.5-15.3), and median procedure time of 28â min (interquartile range 24-33â min) Therapeutic procedure diagnosis were: one ruptured saccular aneurysm, two juvenile nasopharyngeal angiofibromas, and five arteriovenous malformations. The transradial access neurointerventions for pediatric population older than 11 years is safe and feasible, having previous experience in adults. Younger population should be considered on a case-to-case basis, depending on ultrasound measurement of the arterial diameter and the materials available.
Assuntos
Procedimentos Neurocirúrgicos , Artéria Radial , Adolescente , Angiografia/efeitos adversos , Angiografia/métodos , Estudos de Viabilidade , Humanos , Procedimentos Neurocirúrgicos/efeitos adversos , Procedimentos Neurocirúrgicos/métodos , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Resultado do TratamentoRESUMO
CASE DESCRIPTION: A young male patient with a complete section of the ulnar and radial arteries preserved the perfusion of the hand through an anatomical variant, the median artery, identified by angiotomography. CLINICAL FINDINGS: A wound in the distal third of the left forearm with present pulses and adequate hand coloration. An angiotomography of the upper left limb showed a median artery originating as a continuation of the anterior interosseous artery and ending in the palm of the hand with an incomplete superficial palmar arch. TREATMENT AND OUTCOMES: Ligation of both radial and ulnar arteries was performed. It was not possible to follow up the patient. CLINICAL RELEVANCE: Forming the superficial and deep palmar arches, the irrigation of hand comes from the ulnar and radial arteries, which can compromise the viability of the limb when injured. The median artery is present in 0.6-21.1% of the population, originates from the anterior interosseous artery (branch of the ulnar), accompanies the median nerve in its path and ends in the palm joining the superficial palmar arch. Diagnostic imaging is a key tool for assessing arterial circulation and characterizing upper limb vascular lesions. Knowledge of the anatomical variations of the arterial supply of the hand, including variability of the superficial palmar arch, is crucial for the safety and success of hand surgeries.
DESCRIPCIÓN DEL CASO: Un paciente joven de sexo masculino con sección completa de las arterias cubital y radial conservó la perfusión de la mano a través de una variante anatómica, la arteria mediana, identificada por angiotomografía. HALLAZGOS CLÍNICOS: Herida en el tercio distal del antebrazo izquierdo con pulsos presentes y coloración adecuada de la mano. Una angiotomografía del miembro superior izquierdo mostró una arteria mediana que se originaba como continuación de la arteria interósea anterior y terminaba en la palma de la mano con un arco palmar superficial incompleto. TRATAMIENTO Y RESULTADOS: Se realizó la ligadura de las arterias radial y cubital. No fue posible realizar un seguimiento del paciente. RELEVANCIA CLÍNICA: La irrigación de la mano proviene de las arterias cubital y radial, que forman los arcos palmar superficial y profundo, comprometiendo la viabilidad de la extremidad cuando se lesionan. La arteria mediana está presente en el 0.6-21.1% de la población, se origina en la arteria interósea anterior (rama del cubital), acompaña al nervio mediano en su recorrido y termina en la palma uniéndose al arco palmar superficial. El diagnóstico por imagen es una herramienta clave para evaluar la circulación arterial y caracterizar las lesiones vasculares del miembro superior. El conocimiento de las variaciones anatómicas de la irrigación arterial de la mano, incluida la variabilidad del arco palmar superficial, es de importancia crucial para la seguridad y el éxito de las cirugías de la mano.
Assuntos
Mãos/irrigação sanguínea , Artéria Radial/lesões , Artéria Ulnar/lesões , Adulto , Artérias/diagnóstico por imagem , Traumatismos do Antebraço/diagnóstico , Humanos , Masculino , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Artéria Ulnar/diagnóstico por imagem , Artéria Ulnar/cirurgiaRESUMO
BACKGROUND: The upper limb approach utilizing transradial access for combined left and right heart catheterization (CLRHC) and ultrasound-guided antecubital venous access for isolated right heart catheterization (IRHC) are strategies that may reduce risks, especially in anticoagulated patients. combined left and right heart catheterization. OBJECTIVES: To assess safety and feasibility of upper limb approach for IRHC or CLRHC in anticoagulated versus non-anticoagulated patients. METHODS: Ninety-three patients who underwent IRHC or CLRHC with ultrasound-guided antecubital venous access and transradial arterial access were prospectively enrolled. The primary outcome was a composite of procedure failure and incidence of immediate vascular complications. RESULTS: Of the 93 patients, 44 (47%) were on anticoagulation and 49 (53%) were not. Mean age was 54 ± 17 and 53 ± 15 years, respectively. Atrial fibrillation (39% vs 15%) and chronic kidney disease (21% vs 6%) were more common in anticoagulated patients. The main indication for anticoagulation was deep vein thrombosis/pulmonary thromboembolism in 22 patients (50%). The primary outcome occurred in 4 (8%) patients in the non-anticoagulated group as compared with 0 in the anticoagulated group (p = 0.12). Procedure failure occurred in two patients (4%) and immediate vascular complications in two patients (4%) in the non-anticoagulated group (p = 0.3 for all). There was no difference between groups regarding duration of the procedure, radiation dose, fluoroscopy time, post-procedure recovery room time and median time to venous or arterial hemostasis. CONCLUSIONS: The upper limb approach for heart catheterization had similar rates of procedure failure and immediate vascular complications in anticoagulated patients when compared to non-anticoagulated patients.
Assuntos
Cateterismo Cardíaco , Artéria Radial , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Estudos de Viabilidade , Humanos , Pessoa de Meia-Idade , Artéria Radial/diagnóstico por imagem , Extremidade Superior , VeiasRESUMO
PURPOSE: We aimed to evaluate ultrasound-guided distal radial artery (DRA) access to perform abdominopelvic endovascular procedures. METHODS: A prospective, observational study was carried out in a single center between December 2017 and February 2019. Forty-two abdominopelvic endovascular procedures were performed by the same operator in 37 patients with DRA access using a 5 F sheath. Most patients were male (67.6%) with a mean age of 62.0±11.4 years (age range, 27.6-82.8 years). Patient characteristics, including Barbeau's test classification, radial and ulnar sizes and technical success, were evaluated. Patients with a DRA smaller than 1.7 mm could not be safely punctured and were not included. RESULTS: Procedures included chemoembolization of hepatocellular carcinoma in 35 cases (83.3%), embolization of hepatic metastasis in neuroendocrine tumors in 4 cases (9.5%) and other embolization procedures in 3 cases (7.1%). The mean diameters of the DRA, proximal radial artery and proximal ulnar artery were 2.31, 2.63, and 2.09 mm, respectively. Out of 42 DRA puncture attempts, 97.6% (41/42) were successfully performed. There were no postoperative complications related to the access site, such as pain, palsy, paresthesia, occlusion, finger ischemia, bleeding, hematoma, and pseudoaneurysm. Transient forearm discomfort was reported in 7.1% of patients (3/42); one occurrence was associated with kinking rectification, and two occurrences were attributed to small arteries and/or vasospasm. CONCLUSION: Ultrasound-guided DRA access seems to be feasible and safe to perform in abdominopelvic endovascular procedures in patients with a DRA considered amenable to be safely punctured, with high technical success rates.
Assuntos
Procedimentos Endovasculares , Artéria Radial , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Resultado do Tratamento , Ultrassonografia , Ultrassonografia de IntervençãoRESUMO
Arterial catheterization is a common procedure performed for invasive blood pressure as well as cardiac output monitoring and blood sampling for analysis. The fracture or embolization of arterial catheters are rare but serious complications, and may cause vascular thrombosis or occlusion. Ultrasound can be used to identify the intravascular fragment, however their removal may be complex. The authors report a case of intra-arterial catheter fracture in the radial artery, confirmed by ultrasound and surgically removed. This case may alert to be aware of this complication when using this invasive method, helping to prevent future complications for patients.
La introducción de un catéter arterial es un procedimiento realizado regularmente para evaluar la presión arterial invasiva, el gasto cardíaco y tomar muestras de sangre para su análisis. La fractura y la embolización de los catéteres arteriales son complicaciones poco frecuentes pero graves y pueden causar trombosis u oclusión de la arteria. La ecografía puede usarse para identificar el fragmento intravascular, pero la extracción puede ser compleja. Presentamos un caso de fractura intravascular del catéter de la arteria radial confirmada por ecografía y extirpada quirúrgicamente. Este caso señala la necesidad de prestar atención a esta complicación cuando se usa el monitoreo invasivo, para evitar complicaciones futuras para los enfermos.
Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Vasculares , Cateterismo Periférico/efeitos adversos , Remoção de Dispositivo , Corpos Estranhos/cirurgia , Corpos Estranhos/diagnóstico por imagem , Ruptura , Artéria Radial/diagnóstico por imagem , Ultrassonografia Doppler , Falha de Equipamento , Anestésicos/administração & dosagemRESUMO
BACKGROUND: Coronary angiography with two catheters is the traditional strategy for diagnostic coronary procedures. TIG I catheter permits to cannulate both coronary arteries, avoiding exchanging catheters during coronary angiography by transradial access. OBJECTIVE: The aim of this study is to evaluate the impact of one-catheter strategy, by avoiding catheter exchange, on coronary catheterization performance and economic costs. METHODS: Transradial coronary diagnostic procedures conducted from January 2013 to June 2017 were collected. One-catheter strategy (TIG I catheter) and two-catheter strategy (left and right Judkins catheters) were compared. The volume of iodinated contrast administered was the primary endpoint. Secondary endpoints included radial spasm, procedural duration (fluoroscopy time) and exposure to ionizing radiation (dose-area product and air kerma). Direct economic costs were also evaluated. For statistical analyses, two-tailed p-values < 0.05 were considered statistically significant. RESULTS: From a total of 1,953 procedures in 1,829 patients, 252 procedures were assigned to one-catheter strategy and 1,701 procedures to two-catheter strategy. There were no differences in baseline characteristics between the groups. One-catheter strategy required less iodinated contrast [primary endpoint; (60-105)-mL vs. 92 (64-120)-mL; p < 0.001] than the two-catheter strategy. Also, the one-catheter group presented less radial spasm (5.2% vs. 9.3%, p = 0.022) and shorter fluoroscopy time [3.9 (2.2-8.0)-min vs. 4.8 (2.9-8.3)-min, p = 0.001] and saved costs [149 (140-160)-/procedure vs. 171 (160-183)-/procedure; p < 0.001]. No differences in dose-area product and air kerma were detected between the groups. CONCLUSIONS: One-catheter strategy, with TIG I catheter, improves coronary catheterization performance and reduces economic costs compared to traditional two-catheter strategy in patients referred for coronary angiography.
Assuntos
Cateteres Cardíacos/economia , Angiografia Coronária/métodos , Idoso , Cateterismo Cardíaco/economia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Meios de Contraste , Angiografia Coronária/economia , Angiografia Coronária/instrumentação , Redução de Custos/economia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Artéria Radial/diagnóstico por imagem , Doses de Radiação , Radiação Ionizante , Estudos Retrospectivos , Espasmo , Fatores de TempoRESUMO
BACKGROUND: The radial approach has been increasingly used worldwide for diagnostic and therapeutic cardiac catheterization. The radial artery caliber is one of the limitations of its use. The objective of this study was to describe the anatomy of the radial and ulnar arteries, as well as to develop a radial artery diameter prediction score using clinical and anthropometric criteria. METHODS: Using vascular ultrasound with bilateral radial and ulnar artery measurements, 1,180 patients who underwent cardiac catheterization or angioplasty procedures were prospectively evaluated. Using the patients' variables, a radial artery diameter prediction score was developed in a cross-sectional fashion, using half of the sample. The score was validated with the half not used for deriving the model. RESULTS: A total of 1,180 patients were evaluated. The mean internal diameter of the right and left radial arteries was 2.69±0.69mm and 2.53±0.64mm (p<0.01), and the mean internal diameter of the right and left ulnar arteries was 2.09±0.59mm and 2.10±0.60mm (p=0.76), respectively. The factors that positively correlated with arterial size were male sex, previous catheterization, height, weight, and body surface area. The risk score developed using clinical and anthropometric variables had unsatisfactory discriminatory capacity (c-statistics 0.64). CONCLUSION: The right radial artery is the largest forearm artery in most cases. Men and patients who had previously undergone catheterization have a larger mean radial artery diameter. The artery diameter prediction score has modest accuracy for clinical use. (AU)
Assuntos
Cateterismo Cardíaco , Artéria Radial/diagnóstico por imagem , Ultrassonografia Doppler , AnatomiaRESUMO
Abstract Background: Coronary angiography with two catheters is the traditional strategy for diagnostic coronary procedures. TIG I catheter permits to cannulate both coronary arteries, avoiding exchanging catheters during coronary angiography by transradial access. Objective: The aim of this study is to evaluate the impact of one-catheter strategy, by avoiding catheter exchange, on coronary catheterization performance and economic costs. Methods: Transradial coronary diagnostic procedures conducted from January 2013 to June 2017 were collected. One-catheter strategy (TIG I catheter) and two-catheter strategy (left and right Judkins catheters) were compared. The volume of iodinated contrast administered was the primary endpoint. Secondary endpoints included radial spasm, procedural duration (fluoroscopy time) and exposure to ionizing radiation (dose-area product and air kerma). Direct economic costs were also evaluated. For statistical analyses, two-tailed p-values < 0.05 were considered statistically significant. Results: From a total of 1,953 procedures in 1,829 patients, 252 procedures were assigned to one-catheter strategy and 1,701 procedures to two-catheter strategy. There were no differences in baseline characteristics between the groups. One-catheter strategy required less iodinated contrast [primary endpoint; (60-105)-mL vs. 92 (64-120)-mL; p < 0.001] than the two-catheter strategy. Also, the one-catheter group presented less radial spasm (5.2% vs. 9.3%, p = 0.022) and shorter fluoroscopy time [3.9 (2.2-8.0)-min vs. 4.8 (2.9-8.3)-min, p = 0.001] and saved costs [149 (140-160)-€/procedure vs. 171 (160-183)-€/procedure; p < 0.001]. No differences in dose-area product and air kerma were detected between the groups. Conclusions: One-catheter strategy, with TIG I catheter, improves coronary catheterization performance and reduces economic costs compared to traditional two-catheter strategy in patients referred for coronary angiography.
Resumo Fundamento: A cineangiocoronariografia com dois cateteres é a estratégia tradicional para procedimentos coronarianos de diagnóstico. O cateter TIG I permite canular ambas as artérias coronárias, evitando a troca de cateteres durante a cineangiocoronariografia por acesso transradial. Objetivo: O objetivo deste estudo é avaliar o impacto da estratégia de um cateter, evitando a troca de cateter, no desempenho da coronariografia por cateterismo e nos seus custos econômicos. Métodos: Foram coletados os procedimentos diagnósticos coronarianos transradiais realizados entre janeiro de 2013 e junho de 2017. A estratégia de um cateter (cateter TIG I) e a estratégia de dois cateteres (cateteres coronários direito e esquerdo de Judkins) foram comparadas. O volume de contraste iodado administrado foi o endpoint primário. Os endpoints secundários eram espasmo radial, duração do procedimento (tempo de fluoroscopia) e exposição a radiações ionizantes (produto dose-área e kerma no ar). Os custos econômicos diretos também foram avaliados. Para as análises estatísticas, valores de p < 0,05 bicaudais foram considerados estatisticamente significativos. Resultados: De um total de 1.953 procedimentos em 1.829 pacientes, 252 procedimentos foram atribuídos à estratégia de um cateter e 1.701 procedimentos à estratégia de dois cateteres. Não houve diferenças nas características basais entre os grupos. A estratégia de um cateter exigiu menos contraste iodado [endpoint primário; (60-105) -mL vs. 92 (64-120) -mL; p < 0,001] em comparação com a estratégia de dois cateteres. Além disso, o grupo da estratégia de um cateter apresentou menos espasmo radial (5,2% vs. 9,3%, p = 0,022) e menor tempo de fluoroscopia [3,9 (2,2-8,0) -min vs. 4,8 (2,9-8,3) -min, p = 0,001] e economia de custos [149 (140-160)-€/procedimento vs. 171 (160-183) -€/procedimento; p < 0,001]. Não foram detectadas diferenças no produto dose-área e kerma no ar entre os grupos. Conclusões: A estratégia de um cateter, com cateter TIG I, melhora o desempenho da coronariografia por cateterismo e reduz os custos econômicos em comparação com a estratégia tradicional de dois cateteres em pacientes encaminhados para cineangiocoronariografia.
Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Angiografia Coronária/métodos , Cateteres Cardíacos/economia , Doses de Radiação , Radiação Ionizante , Espasmo , Fatores de Tempo , Fluoroscopia , Cateterismo Cardíaco/economia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Estudos Retrospectivos , Redução de Custos/economia , Angiografia Coronária/economia , Angiografia Coronária/instrumentação , Artéria Radial/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Meios de ContrasteRESUMO
OBJECTIVE: Over the past 10 years, the rate of patients who have undergone coronary artery bypass graft (CABG) surgery has increased twofold in cases of coronary angiography. Today, transradial access is the first choice for coronary angiography. We aimed to compare the efficacy and reliability of radial versus femoral access for coronary angiography in post-CABG surgery in this study. METHODS: Data from 442 patients who underwent post-CABG surgery between 2012-2017 were retrospectively compared. The right radial route was used in 120 cases, the left radial route in 148, and femoral route in 174. These three pathways were compared in terms of procedure time and fluoroscopy time, efficacy, and complication development. Comparisons among the three groups were performed with Bonferroni test for continuous variables and chi-square or Fisher's exact test for nominal variables as a binary. RESULTS: Comparison results indicate that femoral access was better than left radial access and the left radial access was better than right radial access in terms of fluoroscopy time (10.71±1.65, 10.94±1.25, 16.12±5.28 min, P<0.001) and total procedure time (17.28±1.68, 17.68±2.34, 23.04±5.84 min, P<0.001). The left radial pathway was the most effective way of viewing left internal mammary artery (LIMA). No statistically significant differences were found among the three groups in other graft visualizations, all minor complications, total procedure and fluoroscopy time "Except LIMA imaging". Mortality due to processing was not observed in all three groups. CONCLUSION: The left radial route is preferred over right radial access for post-CABG angiography because the left radial pathway is close to the LIMA and is similar to the femoral pathway. In LIMA graft imaging, right radial access is a reliable route, even though it is not as effective as other pathways. We hope that the right radial pathway will improve with physician experience and innovations.
Assuntos
Angiografia Coronária/métodos , Ponte de Artéria Coronária/métodos , Artéria Femoral/cirurgia , Artéria Torácica Interna/cirurgia , Artéria Radial/cirurgia , Idoso , Análise de Variância , Aorta/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Feminino , Artéria Femoral/diagnóstico por imagem , Fluoroscopia/métodos , Humanos , Masculino , Artéria Torácica Interna/diagnóstico por imagem , Pessoa de Meia-Idade , Duração da Cirurgia , Artéria Radial/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do TratamentoRESUMO
Abstract Objective: Over the past 10 years, the rate of patients who have undergone coronary artery bypass graft (CABG) surgery has increased twofold in cases of coronary angiography. Today, transradial access is the first choice for coronary angiography. We aimed to compare the efficacy and reliability of radial versus femoral access for coronary angiography in post-CABG surgery in this study. Methods: Data from 442 patients who underwent post-CABG surgery between 2012-2017 were retrospectively compared. The right radial route was used in 120 cases, the left radial route in 148, and femoral route in 174. These three pathways were compared in terms of procedure time and fluoroscopy time, efficacy, and complication development. Comparisons among the three groups were performed with Bonferroni test for continuous variables and chi-square or Fisher's exact test for nominal variables as a binary. Results: Comparison results indicate that femoral access was better than left radial access and the left radial access was better than right radial access in terms of fluoroscopy time (10.71±1.65, 10.94±1.25, 16.12±5.28 min, P<0.001) and total procedure time (17.28±1.68, 17.68±2.34, 23.04±5.84 min, P<0.001). The left radial pathway was the most effective way of viewing left internal mammary artery (LIMA). No statistically significant differences were found among the three groups in other graft visualizations, all minor complications, total procedure and fluoroscopy time "Except LIMA imaging". Mortality due to processing was not observed in all three groups. Conclusion: The left radial route is preferred over right radial access for post-CABG angiography because the left radial pathway is close to the LIMA and is similar to the femoral pathway. In LIMA graft imaging, right radial access is a reliable route, even though it is not as effective as other pathways. We hope that the right radial pathway will improve with physician experience and innovations.
Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Ponte de Artéria Coronária/métodos , Angiografia Coronária/métodos , Artéria Radial/cirurgia , Artéria Femoral/cirurgia , Artéria Torácica Interna/cirurgia , Aorta/diagnóstico por imagem , Fatores de Tempo , Fluoroscopia/métodos , Cateterismo Cardíaco/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Análise de Variância , Resultado do Tratamento , Artéria Radial/diagnóstico por imagem , Artéria Femoral/diagnóstico por imagem , Duração da Cirurgia , Artéria Torácica Interna/diagnóstico por imagemRESUMO
INTRODUCTION:: Blood flow restriction training can be used as an alternative to conventional exercise in chronic kidney disease patients with indication of arteriovenous fistula. OBJECTIVE:: Evaluating the efficacy of blood flow restriction training in the diameter and distensibility change of the cephalic vein and the diameter and flow of the radial artery, muscle strength and forearm circumference in chronic kidney disease patients with arteriovenous fistula pre-creation. METHODS:: A blind randomized clinical trial consisting of 26 chronic kidney disease patients allocated into a blood flow restriction training group (blood flow restriction; n = 12) and a group without blood flow restriction training (control group; n = 14). Blood flow restriction was performed at 50% of systolic blood pressure and using 40% of handgrip strength as load for the isometric exercises in both groups. RESULTS:: An increase in the diameter of the cephalic vein in the 2 cm (p = 0.008) and 10 cm segments (p = 0.001) was observed in the control group. The diameter of the radial artery increased in all segments in the blood flow restriction group (2, 10 and 20 cm; p = 0.005, p = 0.021 and p = 0.018, respectively) and in the 10 and 20 cm segments (p = 0.017 and p = 0.026) in the control group. Handgrip strength only increased in the control group (p = 0.003). CONCLUSION:: Physical training associated with blood flow restriction increased cephalic vein diameters in both groups and was effective in increasing the diameter of the radial artery; however, it did not demonstrate superiority over the exercise group protocol without blood flow restriction.
Assuntos
Derivação Arteriovenosa Cirúrgica , Terapia por Exercício/métodos , Antebraço/irrigação sanguínea , Artéria Radial/cirurgia , Diálise Renal , Insuficiência Renal Crônica/terapia , Veias/cirurgia , Idoso , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Velocidade do Fluxo Sanguíneo , Brasil , Método Duplo-Cego , Terapia por Exercício/efeitos adversos , Feminino , Força da Mão , Humanos , Contração Isométrica , Masculino , Pessoa de Meia-Idade , Artéria Radial/diagnóstico por imagem , Artéria Radial/fisiopatologia , Fluxo Sanguíneo Regional , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/fisiopatologia , Resultado do Tratamento , Veias/diagnóstico por imagem , Veias/fisiopatologiaRESUMO
The radial approach is widely used in the treatment of patients with coronary artery disease. We conducted a meta-analysis of published results on the efficacy and safety of the left and right radial approaches in patients undergoing percutaneous coronary procedures. A systematic search of reference databases was conducted, and data from 14 randomized controlled trials involving 6870 participants were analyzed. The left radial approach was associated with significant reductions in fluoroscopy time [standardized mean difference (SMD)=-0.14, 95% confidence interval (CI)=-0.19 to -0.09; P<0.00001] and contrast volume (SMD=-0.07, 95%CI=-0.12 to -0.02; P=0.009). There were no significant differences in rate of procedural failure of the left and the right radial approaches [risk ratios (RR)=0.98; 95%CI=0.77-1.25; P=0.88] or procedural time (SMD=-0.05, 95%CI=0.17-0.06; P=0.38). Tortuosity of the subclavian artery (RR=0.27, 95%CI=0.14-0.50; P<0.0001) was reported more frequently with the right radial approach. A greater number of catheters were used with the left than with the right radial approach (SMD=0.25, 95%CI=0.04-0.46; P=0.02). We conclude that the left radial approach is as safe as the right radial approach, and that the left radial approach should be recommended for use in percutaneous coronary procedures, especially in percutaneous coronary angiograms.
Assuntos
Humanos , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Artéria Radial/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Fluoroscopia/métodos , Intervenção Coronária Percutânea/efeitos adversos , Artéria Radial/diagnóstico por imagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Artéria Subclávia/anatomia & histologia , Fatores de TempoRESUMO
The radial approach is widely used in the treatment of patients with coronary artery disease. We conducted a meta-analysis of published results on the efficacy and safety of the left and right radial approaches in patients undergoing percutaneous coronary procedures. A systematic search of reference databases was conducted, and data from 14 randomized controlled trials involving 6870 participants were analyzed. The left radial approach was associated with significant reductions in fluoroscopy time [standardized mean difference (SMD)=-0.14, 95% confidence interval (CI)=-0.19 to -0.09; P<0.00001] and contrast volume (SMD=-0.07, 95%CI=-0.12 to -0.02; P=0.009). There were no significant differences in rate of procedural failure of the left and the right radial approaches [risk ratios (RR)=0.98; 95%CI=0.77-1.25; P=0.88] or procedural time (SMD=-0.05, 95%CI=0.17-0.06; P=0.38). Tortuosity of the subclavian artery (RR=0.27, 95%CI=0.14-0.50; P<0.0001) was reported more frequently with the right radial approach. A greater number of catheters were used with the left than with the right radial approach (SMD=0.25, 95%CI=0.04-0.46; P=0.02). We conclude that the left radial approach is as safe as the right radial approach, and that the left radial approach should be recommended for use in percutaneous coronary procedures, especially in percutaneous coronary angiograms.
Assuntos
Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Artéria Radial/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Fluoroscopia/métodos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Artéria Radial/diagnóstico por imagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Artéria Subclávia/anatomia & histologia , Fatores de TempoRESUMO
We report our experience using transradial access (TRA) for carotid artery stenting (CAS). Eighty-eight patients underwent CAS using a nonfemoral approach, 79 of them by TRA. Carotid artery stenting was performed using standard techniques with a long hydrophilic sheath. Mean age was 69.5 years. A total of 46 patients were symptomatic and 34 were asymptomatic. Transradial access and procedural success were achieved in 98.8% and 96.6% of the cases, respectively. There were no deaths, myocardial infarction, or radial access site complications. In all, 2 patients sustained a stroke, 1 hemorrhage, and 1 ischemia. Carotid artery stenting using TRA was safe and technically feasible.
Assuntos
Angioplastia/métodos , Estenose das Carótidas/terapia , Artéria Radial , Idoso , Idoso de 80 Anos ou mais , Angioplastia/efeitos adversos , Angioplastia/instrumentação , Argentina , Doenças Assintomáticas , Estenose das Carótidas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Artéria Radial/diagnóstico por imagem , Radiografia , Estudos Retrospectivos , Índice de Gravidade de Doença , Stents , Fatores de Tempo , Resultado do TratamentoRESUMO
Woman, 67 years old, with unstable angina and history of myocardial revascularization: left internal thoracic artery to anterior descending artery and graft with radial artery (RA) to right coronary artery branches. Coronariography showed stenosis of 90% in the RA graft, treated with conventional stent. After two months, the patient developed unstable angina related to in-stent restenosis, treated with sirolimus-eluting stent. In the follow-up, six months after implantation, the patient was asymptomatic and maintening the outcome of the implant. This case report demonstrates the technical difficulties of percutaneous intervention in RA grafts and treatment outcome of in-stent restenosis with sirolimus stent.
Assuntos
Reestenose Coronária/tratamento farmacológico , Stents Farmacológicos , Oclusão de Enxerto Vascular/terapia , Revascularização Miocárdica/métodos , Artéria Radial/transplante , Sirolimo/uso terapêutico , Idoso , Angiografia Coronária , Feminino , Humanos , Artéria Radial/diagnóstico por imagem , Resultado do TratamentoRESUMO
OBJECTIVE: To compare the radial artery and saphenous vein's patency in patients with recurrence of symptoms in a coronary artery bypass grafting (CABG). METHODS: Retrospective study. From January 1998 to December 2005, 469 CABGs were performed using the radial artery as a graft, in Vera Cruz Hospital in Belo Horizonte/ MG. Among the patients who underwent those surgeries, 94 presented ischemic changes in early or late postoperative period, which led them to be re-evaluated by coronary angiography. The grafts were divided in three groups: internal thoracic artery (ITA), radial artery (RA) and saphenous vein (SV), and they were stratified according to the severity of injury: uninjured or patent (< 70%), severe obstruction (70 to 99%) and occlusion. RESULTS: For the 94 patients in the study, 86 grafts of ITA, 94 of RA and 111 of SV were used. For the 86 ITA grafts, 73 (84.88%) were found patent. For the 94 RA grafts, 55 (58.51%) were found patent, and for the 111 SV grafts, 73 (65.76%) were uninjured. A statistically significant difference (P= 0.001) was found between RA and SV grafts, with a higher patency found for VS graft. For the RA grafts, women presented a worse result concerning the RA patency (65.7% and 40.7%), with P = 0.006. Concerning coronary revascularization, a statistically significant difference was found only for the grafts used for the right coronary, with a better result for the SV (P = 0.036). CONCLUSION: Radial artery (RA) presented worse results when compared to Saphenous vein (SV) as a second graft in a CABG, especially in women who were anastomosed in the right coronary artery.
Assuntos
Ponte de Artéria Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Oclusão de Enxerto Vascular/diagnóstico por imagem , Artéria Radial/diagnóstico por imagem , Veia Safena/diagnóstico por imagem , Adulto , Idoso , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial/transplante , Radiografia , Veia Safena/transplante , Resultado do Tratamento , Grau de Desobstrução Vascular/fisiologiaRESUMO
OBJECTIVE: Left internal thoracic artery (LITA) grafting has become the gold standard in coronary artery bypass graft procedure (CABG). In order to optimize the use of LITA or other grats, sequential anastomosis has been used. There is no consensus on equivalence of results between isolated and sequential grafts. The aim of this study is to compare the patency of isolated versus sequential grafts. METHODS: From January 2000 to August 2007, a retrospective patency analysis of the grafts used in 88 symptomatic patients who underwent CABG procedure in our Service was performed through cinecoronariography. Statistical analysis was performed through Student's t test. Each distal anastomosis was considered an independent graft. RESULTS: The mean postoperative period was of 53 +/- 138 months and mean age was 64 +/- 11 years. LITA isolated grafts presented patency rate significantly higher than the sequential grafts, respectively 92% (46/50) and 77% (30/39) P = 0.02. However, in injured coronary arteries of >or= 70%, isolated LITA patency rate was similar to sequential grafts, (95%; 37/39) and (93%; 26/28) respectively; P = 0.37. Mean radial artery patency rate was similar to isolated 71% (5/7) and sequential 90% (19/21) grafts; P = 0.10. Saphenous vein patency rates were similar for isolated 72% (31/43) and sequential 81% (73/90) grafts; P = 0.12. There was no difference between radial artery and saphenous vein patency rates. CONCLUSION: In symptomatic patients, isolated LITA patency is superior than sequential LITA. However, in coronary injuries of >or= 70%, the isolated and sequential patency rates are similar. Sequential grafts from radial artery and saphenous vein are similar to their respective isolated grafts.