Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.669
Filtrar
1.
Trends Hear ; 28: 23312165241259704, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38835268

RESUMO

The use of in-situ audiometry for hearing aid fitting is appealing due to its reduced resource and equipment requirements compared to standard approaches employing conventional audiometry alongside real-ear measures. However, its validity has been a subject of debate, as previous studies noted differences between hearing thresholds measured using conventional and in-situ audiometry. The differences were particularly notable for open-fit hearing aids, attributed to low-frequency leakage caused by the vent. Here, in-situ audiometry was investigated for six receiver-in-canal hearing aids from different manufacturers through three experiments. In Experiment I, the hearing aid gain was measured to investigate whether corrections were implemented to the prescribed target gain. In Experiment II, the in-situ stimuli were recorded to investigate if corrections were directly incorporated to the delivered in-situ stimulus. Finally, in Experiment III, hearing thresholds using in-situ and conventional audiometry were measured with real patients wearing open-fit hearing aids. Results indicated that (1) the hearing aid gain remained unaffected when measured with in-situ or conventional audiometry for all open-fit measurements, (2) the in-situ stimuli were adjusted for up to 30 dB at frequencies below 1000 Hz for all open-fit hearing aids except one, which also recommends the use of closed domes for all in-situ measurements, and (3) the mean interparticipant threshold difference fell within 5 dB for frequencies between 250 and 6000 Hz. The results clearly indicated that modern measured in-situ thresholds align (within 5 dB) with conventional thresholds measured, indicating the potential of in-situ audiometry for remote hearing care.


Assuntos
Limiar Auditivo , Auxiliares de Audição , Humanos , Estimulação Acústica , Ajuste de Prótese/métodos , Reprodutibilidade dos Testes , Audiometria/métodos , Audiometria de Tons Puros , Perda Auditiva/diagnóstico , Perda Auditiva/reabilitação , Perda Auditiva/fisiopatologia , Audição , Valor Preditivo dos Testes , Pessoas com Deficiência Auditiva/reabilitação , Pessoas com Deficiência Auditiva/psicologia , Desenho de Equipamento , Masculino , Feminino
2.
Medicina (Kaunas) ; 60(5)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38792986

RESUMO

Background and Objectives: Besides classical stapedotomy, reverse stapedotomy has been used for many years in the management of otosclerosis. Our study aims to investigate whether reversing the surgical steps in stapedotomy impacts vestibular function and hearing improvement. Materials and Methods: A cohort of 123 patients underwent either classic or reverse stapedotomy procedures utilizing a fiber-optic argon laser. Audiological assessments, following the guidelines of the Committee on Hearing and Equilibrium, were conducted, including pure tone average, air-bone (AB) gap, overclosure, and AB gap closure. Vestibular evaluation involved pre- and postoperative comparison of rotatory test parameters, including frequency, amplitude, and slow phase velocity of nystagmus. Results: The study demonstrated an overall median overclosure of 3.3 (3.3, 5.0) dB and a mean AB gap closure of 20.3 ± 8.8 dB. Postoperative median AB gap was 7.5 (7.5, 11.3) dB in the reverse stapedotomy group and 10.0 (10.0, 12.5) dB in the classic stapedotomy group. While overclosure and AB gap closure were marginally superior in the reverse stapedotomy group, these differences did not reach statistical significance. No significant disparities were observed in the frequency, slow phase velocity, or amplitude of nystagmus in the rotational test. Conclusions: Although not always possible, reverse stapedotomy proved to be a safe surgical technique regarding postoperative outcomes. Its adoption may mitigate risks associated with floating footplate, sensorineural hearing loss, and incus luxation/subluxation, while facilitating the learning curve for less experienced ear surgeons.


Assuntos
Otosclerose , Cirurgia do Estribo , Humanos , Cirurgia do Estribo/métodos , Cirurgia do Estribo/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Otosclerose/cirurgia , Otosclerose/fisiopatologia , Audiometria/métodos , Estudos de Coortes , Resultado do Tratamento , Audiometria de Tons Puros/métodos , Idoso , Testes de Função Vestibular/métodos
3.
Artigo em Chinês | MEDLINE | ID: mdl-38811175

RESUMO

Objective: This study aimed to compare the audiological characteristics between children with unilateral auditory neuropathy (UAN) and single-sided deafness (SSD) to establish a valid basis for the differential diagnosis of children with UAN. Methods: A retrospective analysis was conducted on audiological and imaging evaluations of children with UAN and SSD who were treated at Beijing Children's Hospital of Capital Medical University between May 2015 and June 2023. There were 17 children with UAN, comprising 10 males and 7 females, with an average age of 4.7 years. Additionally, there were 43 children with SSD, consisting of 27 males and 16 females, with an average age of 6.5 years. Audiological assessments included Auditory brainstem response (ABR), Steady-state auditory evoked potential (ASSR), Behavioural audiometry, Cochlear microphonic potential (CM), Distortino-product otoacoustic emission (DPOAE), and acoustic immittance test. The results of the audiological assessment and imaging phenotypic between the two groups of children were compared and analyzed by applying SPSS 27.0 statistical software. Results: (1) The UAN group (77.8%) had a significantly higher rate of ABR wave IIIL than the SSD group (20.9%) (P<0.01). The PA thresholds at 500 Hz and 1 000 Hz of children with SSD were higher than those of children with UAN, while the ASSR thresholds at 500 Hz, 1000 Hz, 2 000 Hz, and 4 000 Hz of children with SSD were significantly higher than those of children with UAN (P<0.05). (2) The degree of hearing loss in both UAN and SSD children was predominantly complete hearing loss. The percentage of complete hearing loss was significantly higher (χ²=4.353, P=0.037) in the SSD group (93.0%, 40/43) than in the UAN group (63.6%, 7/11). However, the percentage of profound hearing loss was significantly higher in the UAN group (27.3%, 3/11) than in the SSD group (2.3%, 1/43) (Fisher's exact test, P=0.023). In terms of hearing curve configuration, the percentage of flat type was significantly higher in the SSD group (76.7%, 33/43) than in the UAN group (36.4%, 4/11). The proportion of the UAN group (27.3%, 3/11) was significantly higher than that in the SSD group (2.3%, 1/43) in ascending type (P<0.05). There were no statistically significant differences in the hearing curves of the declining type and other types between the two groups (P>0.05). (3) The proportion of imaging assessment without abnormality was significantly more common in the UAN group (81.8%) than in the SSD group (37.1%) (χ²=6.695, P=0.015). Conclusions: Compared to children with SSD, the occurrence of wave IIIL on the ABR test was significantly more common in children with UAN. The percentage of ascending hearing curves was significantly higher in children with UAN than in children with SSD. ASSR thresholds were significantly lower in children with UAN. The normal imaging phenotype was significantly more common in children with UAN than in children with SSD.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva Central , Humanos , Feminino , Masculino , Estudos Retrospectivos , Pré-Escolar , Criança , Perda Auditiva Central/diagnóstico , Perda Auditiva Central/fisiopatologia , Perda Auditiva Unilateral/diagnóstico , Perda Auditiva Unilateral/fisiopatologia , Limiar Auditivo , Audiometria/métodos , Diagnóstico Diferencial
4.
Int J Pediatr Otorhinolaryngol ; 181: 111982, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38776720

RESUMO

OBJECTIVE: To describe the prevalence of routine white noise exposure in children who undergo sound field audiometry. METHODS: A retrospective cohort study was conducted at a pediatric otolaryngology clinic affiliated with an academic tertiary care hospital. The medical records of children who underwent sound field audiometry were reviewed and data was collected regarding demographics and audiogram results. The group was divided into two cohorts based on routine exposure to white noise. Children exposed to white noise were tested with warble tones, while those not exposed were tested with narrow-band noise. RESULTS: 127 patients underwent sound field audiometry testing, of which 96 (75.6%) were reported by their parents to use white noise for sleep. The mean age at time of testing was 1.6 years (95% Confidence Interval [CI] 1.5-1.7). 104 (81.9%) children were able to respond to at least four of the sound field thresholds, and there was no significant difference between the children exposed to white noise and those who were not (P = 0.459). Mean pure tone average (PTA) was 26.2 dB (95% CI 25.2-27.2) and mean speech reception threshold (SRT) was 19.2 dB (95% CI 18.2-20.2). The sound field response rate, PTA, and SRT were similar between these two groups. CONCLUSIONS: The routine use of white noise therapy was extremely common in this pediatric population. The use of warble tones as the audiometric stimuli for children exposed to white noise resulted in similar testing success compared to the use of narrow-band noise in children not exposed to white noise.


Assuntos
Audiometria de Tons Puros , Ruído , Humanos , Masculino , Feminino , Estudos Retrospectivos , Ruído/efeitos adversos , Lactente , Pré-Escolar , Perda Auditiva Provocada por Ruído/diagnóstico , Perda Auditiva Provocada por Ruído/epidemiologia , Perda Auditiva Provocada por Ruído/etiologia , Limiar Auditivo , Estudos de Coortes , Criança , Audiometria/métodos , Prevalência
5.
Am J Otolaryngol ; 45(4): 104345, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38701729

RESUMO

PURPOSE: To assess the audiometric outcomes following surgical repair of spontaneous temporal bone cerebrospinal fluid otorrhea and compare different surgical approaches. MATERIALS AND METHODS: Retrospective review of adults (≥18 years old) who underwent repair of spontaneous CSF leak between 2011 and 2022. Audiometric outcomes were compared across the three surgical groups: transmastoid, middle cranial fossa and combined. RESULTS: Thirty-nine patients (40 ears) met the inclusion criteria (71.8 % females; mean age 59.77 +/- 12.4). Forty-two percent underwent transmastoid, 12.5 % middle cranial fossa and 45 % transmastoid-middle cranial fossa. Four patients (10 %) had recurrence, 3 in the transmastoid group and 1 in the combined approach. The mean change in air-bone gap (ABG) for all patients (postoperative-preoperative) was -7.4 (paired t-test, p-value = 0.0003). The postoperative ABG was closed in 28 (70 %) ears (postoperative ABG ≤ 15). The mean change in pure tone average (PTA) for all patients (postoperative-preoperative) was -4.1 (paired t-test, p-value = 0.13). The mean change in word recognition scores (WRS) for all patients (postoperative-preoperative) was -3 (paired t-test, p-value = 0.35). On multivariable analysis (controlling for site and reconstruction material), there was no significant difference in ABG, PTA and WRS change between surgical groups. CONCLUSIONS: Transmastoid, middle cranial fossa and combined approaches are all effective in treatment of spontaneous CSF leaks and all showed mean decrease in post-operative ABG. Transmastoid approach showed the greatest decrease in ABG and PTA (although middle cranial fossa approach shows the greatest decrease, when excluding profound hearing loss in a patient with superior canal dehiscence). Further studies comparing audiometric outcomes are needed.


Assuntos
Otorreia de Líquido Cefalorraquidiano , Osso Temporal , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Osso Temporal/cirurgia , Otorreia de Líquido Cefalorraquidiano/cirurgia , Otorreia de Líquido Cefalorraquidiano/etiologia , Resultado do Tratamento , Idoso , Fossa Craniana Média/cirurgia , Audiometria de Tons Puros , Adulto , Vazamento de Líquido Cefalorraquidiano/cirurgia , Vazamento de Líquido Cefalorraquidiano/etiologia , Processo Mastoide/cirurgia , Audiometria
6.
Am J Otolaryngol ; 45(4): 104346, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38703613

RESUMO

OBJECTIVES: Recently, patients with certain legacy cochlear implants (CIs) have sought out reimplantation to enjoy the benefits offered by newer processor technology. This decision can be difficult, especially when the individual relies exclusively on the device for communication and scores at the ceiling of performance metrics. To date, most outcome data is derived from reimplantation of a non-functioning CI-a relatively easy decision. The aim of this study is to report hearing outcomes following reimplantation of legacy implants to guide surgeons and patients approaching this high-stakes clinical situation. PATIENTS AND INTERVENTION: Four patients implanted with Advanced Bionics Clarion C1 devices over 20 years ago underwent reimplantation. RESULTS: Three reimplanted patients demonstrated a maintenance or improvement in their audiometric performance with one patient experiencing only a 5 % decrease in AzBioQ score. Each patient expressed satisfaction with the expansion of technological capabilities including improved battery life, and device connectivity. There were no failed reimplantations or other adverse effects. CONCLUSIONS: Reimplantation of a functioning legacy CI result in stability or improvement in auditory performance. All individuals in this series report that they enjoy the new connectivity and programming technologies. As the rate advancement in CI technology continues to increase and newer device architectures emerge, these data will help to inform the decision to reimplant functioning devices.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Resultado do Tratamento , Implante Coclear/métodos , Reimplante/métodos , Reoperação , Adulto , Idoso , Audição , Satisfação do Paciente , Audiometria
7.
Trends Hear ; 28: 23312165241242235, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38738302

RESUMO

The objective of this project was to establish cutoff scores on the tinnitus subscale of the Tinnitus and Hearing Survey (THS) using a large sample of United States service members (SM) with the end goal of guiding clinical referrals for tinnitus evaluation. A total of 4,589 SM undergoing annual audiometric surveillance were prospectively recruited to complete the THS tinnitus subscale (THS-T). A subset of 1,304 participants also completed the Tinnitus Functional Index (TFI). The original 5-point response scale of the THS (THS-T16) was modified to an 11-point scale (THS-T40) for some participants, to align with the response scale of the TFI. Age, sex, hearing loss, and self-reported tinnitus bother were also recorded. The THS-T was relatively insensitive to hearing, but self-reported bothersome tinnitus was significantly associated with the THS-T40 score. Receiver operating characteristic analysis was used to determine cutoff scores on the THS-T that aligned with recommended cutoff values for clinical intervention on the TFI. A cutoff of 9 on the THS-T40 aligns with a TFI cutoff of 25, indicating a patient may need intervention for tinnitus. A cutoff of 15 aligns with a TFI cutoff of 50, indicating that more aggressive intervention for tinnitus is warranted. The THS-T is a viable tool to identify patients with tinnitus complaints warranting clinical evaluation for use by hearing conservation programs and primary care clinics. The THS-T40 cutoff scores of 9 and 15 provide clinical reference points to guide referrals to audiology.


Assuntos
Zumbido , Humanos , Zumbido/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Estudos Prospectivos , Estados Unidos , Audição , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Curva ROC , Inquéritos e Questionários , Autorrelato , Audiometria/métodos
8.
Am Fam Physician ; 109(4): 316-323, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38648830

RESUMO

Hearing loss is a prevalent, chronic condition in the United States; it is often gradual and progressive and is underreported by patients and undertreated by physicians. The impaired ability to effectively hear and communicate may result in negative emotional, cognitive, economic, and social consequences for individuals and may pose a safety risk. Questionnaires and smartphone apps are available to help identify and evaluate self-perceived hearing loss. Physicians should assess for objective hearing impairment when the patient or family member raises a concern or if cognitive or mood symptoms are present that could be influenced by hearing loss. Three types of hearing loss exist: conductive, sensorineural, and mixed. Pure-tone audiometry uses an audiometer and is reported on an audiogram; it is the most accurate method for hearing loss detection. It can be used for screening or comprehensive testing when combined with tympanometry, speech-reception thresholds, and word-recognition testing. Audiograms that show a unilateral or asymmetrical sensorineural hearing loss can be signs of retrocochlear pathology and warrant additional evaluation by an audiologist and otolaryngologist as well as imaging studies. Medicare Parts A and B do not pay for hearing aids, although some Medicare Advantage (Part C) or supplemental plans may provide insurance coverage for hearing aids. Less expensive, over-the-counter hearing aids may help mild to moderate hearing loss. Family physicians should counsel patients on the importance of protecting their hearing.


Assuntos
Perda Auditiva , Humanos , Perda Auditiva/diagnóstico , Adulto , Estados Unidos , Audiometria de Tons Puros/métodos , Audiometria/métodos
9.
Am J Otolaryngol ; 45(4): 104294, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38657534

RESUMO

PURPOSE: The number of cochlear implant (CI) surgeries is growing over time, with the risk of overloading CI centers in the post-surgical management. Telemedicine is a possible solution to address this phenomenon. Remote Check (RC) is an application that is specific for CI recipients monitoring. The aim of this study is to evaluate the feasibility of application, potential economic impact and patients' acceptance of RC. METHODS: The study is retrospective investigation, data on clinical, audiological features (from remote and on-site evaluation), and satisfaction surveys of 66 consecutive patients were collected; costs required for RC and for on-site evaluations were recorded as well. RESULTS: One hundred and ninety RC sessions were completed by the patients (2.88 sessions per patient). RC and on-site audiometry significantly correlated except for the 500 Hz frequency. Estimated costs for the Italian National Health System for RC review and on-site evaluations were 1.32€ and 3.49€ per minute, respectively. High satisfaction for RC was reached in 91 % of patients. CONCLUSION: RC revealed to be a reliable, cost-effective and well accepted tool in CI monitoring. This study preliminarily supports the hypothesis that RC could be a valid instrument to reduce CI management overload in the outpatient clinic.


Assuntos
Implante Coclear , Implantes Cocleares , Estudos de Viabilidade , Satisfação do Paciente , Telemedicina , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Implantes Cocleares/economia , Implante Coclear/métodos , Implante Coclear/economia , Idoso , Adolescente , Adulto Jovem , Análise Custo-Benefício , Itália , Audiometria , Criança , Idoso de 80 Anos ou mais
10.
Am J Otolaryngol ; 45(4): 104337, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38677145

RESUMO

OBJECTIVE: To describe an AI model to facilitate adult cochlear implant candidacy prediction based on basic demographical data and standard behavioral audiometry. METHODS: A machine-learning approach using retrospective demographic and audiometric data to predict candidacy CNC word scores and AzBio sentence in quiet scores was performed at a tertiary academic center. Data for the model were derived from adults completing cochlear implant candidacy testing between January 2011 and March 2023. Comparison of the prediction model to other published prediction tools and benchmarks was performed. RESULTS: The final dataset included 770 adults, encompassing 1045 AzBio entries, and 1373 CNC entries. Isophoneme scores and word recognition scores exhibited strongest importance to both the CNC and AzBio prediction models, followed by standard pure tone average and low-frequency pure tone average. The mean absolute difference between the predicted and actual score was 15 percentage points for AzBio sentences in quiet and 13 percentage points for CNC word scores, approximating anticipated test-retest constraints inherent to the variables incorporated into the model. Our final combined model achieved an accuracy of 87 % (sensitivity: 90 %; precision: 80 %). CONCLUSION: We present an adaptive AI model that predicts adult cochlear implant candidacy based on routine behavioral audiometric and basic demographical data. Implementation efforts include a public-facing online prediction tool and accompanying smartphone program, an embedded notification flag in the electronic medical record to alert providers of potential candidates, and a program to retrospectively engage past patients who may be eligible for cochlear implantation based on audiogram results.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Estudos Retrospectivos , Implante Coclear/métodos , Idoso , Audiometria/métodos , Aprendizado de Máquina , Seleção de Pacientes , Adulto Jovem , Idoso de 80 Anos ou mais
11.
Am J Audiol ; 33(2): 476-491, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38668699

RESUMO

PURPOSE: This project addressed the uses of a loudspeaker array for audiometric measurements. It sought to evaluate a prototype compact array in terms of the reliability of test results across sound booths. METHOD: A seven-loudspeaker array was developed to deliver sounds from -60° to +60° on an arc with a radius of 0.5 m. The system was equipped with a head position sensing system to maintain the listener's head near the optimal test position. Three array systems were distributed to each of the two test sites for within-subject assessments of booth equivalence on tests of sound localization, speech reception in noise, and threshold detection. A total of 36 subjects participated, 18 at each test site. RESULTS: Results showed excellent interbooth consistency on tests of sound localization using speech and noise signals, including conditions in which one or both ears were covered with a muff. Booth consistency was also excellent on sound field threshold measurements for detecting quasi-diffuse noise bands. Nonequivalence was observed in some cases of speech-in-noise tests, particularly with a small one-person booth. Acoustic analyses of in situ loudspeaker responses indicated that some of the nonequivalent comparisons on speech-in-noise tests could be traced to the effects of reflections. CONCLUSIONS: Overall, the results demonstrate the utility and reliability of a compact array for the assessment of localization ability, speech reception in noise, and sound field thresholds. However, the results indicate that researchers and clinicians should be aware of the reflection effects that can influence the results of sound field tests in which signal and noise levels from separate loudspeakers are critical.


Assuntos
Localização de Som , Humanos , Masculino , Adulto , Feminino , Reprodutibilidade dos Testes , Desenho de Equipamento , Adulto Jovem , Ruído , Audiometria/métodos , Audiometria/instrumentação , Limiar Auditivo , Amplificadores Eletrônicos , Percepção da Fala , Pessoa de Meia-Idade
12.
Otol Neurotol ; 45(4): 430-433, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38437820

RESUMO

OBJECTIVE: To describe the experience and results from coordinated and closely scheduled radiosurgery and cochlear implantation (CI) in a vestibular schwannoma (VS) cohort. PATIENTS: Patients with VS who underwent radiosurgery followed by CI on the same or next day. INTERVENTIONS: Interventions included sequential radiosurgery and CI. MAIN OUTCOME MEASURES: Tumor control defined by tumor growth on posttreatment surveillance and audiometric outcomes including consonant-nucleus-consonant words and AzBio sentences in quiet. RESULTS: In total, six patients were identified that met the inclusion criteria, with an age range of 38 to 69 years and tumor sizes ranging from 2.0 to 16.3 mm. All patients successfully underwent radiosurgery and CI on the same or immediately successive day. Postoperatively, all patients obtained open-set speech recognition. Consonant-nucleus-consonant word scores ranged from 40 to 88% correct, and AzBio scores ranged from 44 to 94% correct. During posttreatment magnetic resonance imaging surveillance, which ranged from 12 to 68 months, all tumors were noted to be adequately visualized, and no tumor progression was noted. CONCLUSION: Coordinated radiosurgery and CI can be safely performed in patients with VS on the same or next day, serving to decrease burden on patients and increase access to this vital rehabilitative strategy.


Assuntos
Implante Coclear , Implantes Cocleares , Neuroma Acústico , Radiocirurgia , Percepção da Fala , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Implante Coclear/métodos , Neuroma Acústico/cirurgia , Radiocirurgia/métodos , Estudos Retrospectivos , Audiometria , Resultado do Tratamento
13.
Clin Exp Rheumatol ; 42(4): 872-878, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38489315

RESUMO

OBJECTIVES: Neurosensory hearing loss is well-documented in chronic autoimmune conditions such as systemic lupus erythematosus (SLE). However, the literature lacks data on the prevalence and characteristics of hearing impairment in Takayasu's arteritis (TAK). In this cross-sectional study, our principal objective was to systematically assess the auditory function of individuals diagnosed with TAK, against SLE patients and healthy controls (HC). METHODS: Age and gender matched TAK and SLE patients followed up in a tertiary centre along with healthy controls were included in a two-phase study. In the first phase, a questionnaire on ENT symptoms was administered to the patient (TAK: n=104 and SLE: n= 151) and HC (n=174) groups. In the second phase, patients (TAK: n=53 and SLE: n=33) and HC (n=45) underwent audiometric tests. RESULTS: The questionnaire survey revealed that both TAK and SLE patients reported hearing loss (27.9%, 25.8%, 7.4%, p<0.001), tinnitus (49%, 35.8%, 13.8%, p<0.001) and vertigo (46.2%, 33.8%, 16.7%, p<0.001) at significantly higher rates than HC. Audiometry results indicated that both TAK (30.2%) and SLE patients (18.2%) had increased hearing loss compared to HC (8.9%), however, only TAK patients were found to have significantly increased risk in age adjusted logistic regression analysis (OR= 3.915, 95%CI: 1.179-12.998, p=0.026). Hearing loss was mainly neurosensory in all groups. TAK patients were affected at both low (<6000 Hz) and high (>6000 Hz) frequencies, whereas SLE patients were affected only at high frequencies. Hearing loss was significantly associated only with older age. No association was observed with the anatomical location of vascular involvement or history of stroke. CONCLUSIONS: Our study reveals an increased prevalence of hearing loss in TAK. Further research is crucial to uncover the underlying causes.


Assuntos
Lúpus Eritematoso Sistêmico , Arterite de Takayasu , Zumbido , Vertigem , Humanos , Arterite de Takayasu/epidemiologia , Arterite de Takayasu/complicações , Arterite de Takayasu/diagnóstico , Feminino , Masculino , Adulto , Estudos Transversais , Lúpus Eritematoso Sistêmico/complicações , Lúpus Eritematoso Sistêmico/epidemiologia , Lúpus Eritematoso Sistêmico/diagnóstico , Prevalência , Pessoa de Meia-Idade , Zumbido/etiologia , Zumbido/epidemiologia , Zumbido/diagnóstico , Inquéritos e Questionários , Estudos de Casos e Controles , Vertigem/etiologia , Vertigem/epidemiologia , Vertigem/fisiopatologia , Fatores de Risco , Perda Auditiva/epidemiologia , Perda Auditiva/etiologia , Perda Auditiva/diagnóstico , Adulto Jovem , Modelos Logísticos , Centros de Atenção Terciária , Audição , Audiometria , Razão de Chances
14.
J Neurosurg Pediatr ; 33(5): 496-504, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38427998

RESUMO

OBJECTIVE: Pediatric data regarding treatment via an auditory brainstem implant (ABI) remains sparse. The authors aimed to describe their experience at their institution and to delineate associated demographic data, audiometric outcomes, and surgical parameters. METHODS: An IRB-approved, retrospective chart review was conducted among the authors' pediatric patients who had undergone auditory brainstem implantation between 2012 and 2021. Demographic information including sex, age, race, coexisting syndrome(s), history of cochlear implant placement, average duration of implant use, and follow-up outcomes were collected. Surgical parameters collected included approach, intraoperative findings, number of electrodes activated, and complications. RESULTS: A total of 19 pediatric patients had an ABI placed at the authors' institution, with a mean age at surgery of 4.7 years (range 1.5-17.8 years). A total of 17 patients (89.5%) had bilateral cochlear nerve aplasia/dysplasia, 1 (5.3%) had unilateral cochlear nerve aplasia/dysplasia, and 1 (5.3%) had a hypoplastic cochlea with ossification. A total of 11 patients (57.9%) had a history of cochlear implants that were ineffective and required removal. The mean length of implant use was 5.31 years (0.25-10 years). Two patients (10.5%) experienced CSF-related complications requiring further surgical intervention. The most recent audiometric outcomes demonstrated that 15 patients (78.9%) showed improvement in their hearing ability: 5 with sound/speech awareness, 5 able to discriminate among speech and environmental sounds, and 5 able to understand common phrases/conversation without lip reading. Nine patients (47.4%) are in a school for the deaf and 7 (36.8%) are in a mainstream school with support. CONCLUSIONS: The authors' surgical experience with a multidisciplinary team demonstrates that the retrosigmoid approach for ABI placement in children with inner ear pathologies and severe sensorineural hearing loss is a safe and effective treatment modality. Audiometric outcome data showed that nearly 79% of these patients had an improvement in their environmental and speech awareness. Further multicenter collaborations are necessary to improve these outcomes and potentially standardize/enhance electrode placement.


Assuntos
Audiometria , Implante Auditivo de Tronco Encefálico , Humanos , Criança , Masculino , Feminino , Pré-Escolar , Adolescente , Estudos Retrospectivos , Lactente , Implante Auditivo de Tronco Encefálico/métodos , Resultado do Tratamento , Implantes Auditivos de Tronco Encefálico , Nervo Coclear/cirurgia , Nervo Coclear/anormalidades , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia
15.
Trends Hear ; 28: 23312165241240353, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38545653

RESUMO

Exposure to intense low-frequency sounds, for example inside tanks and armoured vehicles, can lead to noise-induced hearing loss (NIHL) with a variable audiometric pattern, including low- and mid-frequency hearing loss. It is not known how well existing methods for diagnosing NIHL apply in such cases. Here, the audiograms of 68 military personnel (mostly veterans) who had been exposed to intense low-frequency noise (together with other types of noise) and who had low-frequency hearing loss (defined as a pure-tone average loss at 0.25, 0.5 and 1 kHz ≥20 dB) were used to assess the sensitivity of three diagnostic methods: the method of Coles, Lutman and Buffin, denoted CLB, which depends on the identification of a notch or bulge in the audiogram near 4 kHz, and two methods specifically intended for diagnosing NIHL sustained during military service, the rM-NIHL method, which depends on the identification of a notch or bulge in the audiogram near 4 kHz and/or a hearing loss at high frequencies greater than expected from age alone, and the MLP(18) method based on a multi-layer perceptron. The proportion of individuals receiving a positive diagnosis for either or both ears, which provides an approximate measure of sensitivity, was 0.40 for the CLB method, 0.79 for the rM-NIHL method and 1.0 for the MLP(18) method. It is concluded that the MLP(18) method is suitable for diagnosing NIHL sustained during military service whether or not the exposure includes intense low-frequency sounds.


Assuntos
Surdez , Perda Auditiva Provocada por Ruído , Ruído Ocupacional , Humanos , Perda Auditiva Provocada por Ruído/diagnóstico , Perda Auditiva Provocada por Ruído/epidemiologia , Perda Auditiva Provocada por Ruído/etiologia , Audiometria/métodos , Testes Auditivos
16.
Int J Pediatr Otorhinolaryngol ; 179: 111925, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38552429

RESUMO

OBJECTIVE: The Baha SoundArc coupling system has been developed as a non-surgical coupling of a Baha sound processor to the skull allowing the transfer of vibrational energy to the cochlear partition via bone conduction pathways. Today, there are several alternatives to this non-surgical approach as the Baha headband/test band, or the Baha Softband, or adhesive patches. Each of these current options have benefits and liabilities. The aim of the study was to evaluate pediatric experience and performance when using two non-surgical options, the Baha SoundArc compared to the Baha Softband. METHODS: Twenty-five children with unilateral mixed or conductive hearing loss aged 5-12 years of age evaluated the use of the Baha SoundArc compared to their existing Baha Softband in a one month take home trial. Participants had a minimum of 3 months experience using the control, Baha Softband. Participants were assessed at baseline and one month following fit of the Baha SoundArc. Measures included an experience and use patient reported outcome, speech perception testing in quiet using Phonetically Balanced Kindergarten (PBK) words, and sound field audiometry. RESULTS: Mean aided soundfield thresholds across the frequency range were 27.6 dB HL for Softband and 26.0 dB HL for SoundArc, which were not significantly different (P = >.05). Mean word recognition score was 80.8% when aided with the Softband device and 85.1% with the SoundArc, which was also not significantly different (P = >.05). Most children favored the aesthetics and usability of the SoundArc over Softband, but comfort ratings were largely similar for both devices. CONCLUSIONS: Bone conduction sound processors mounted on a SoundArc or a Softband resulted in comparable improvements in aided thresholds and speech understanding in children suffering from conductive or mixed hearing loss. Both wearing modalities can be considered equivalent in terms of audiological outcomes, although both patients and clinicians preferred the usability and aesthetics of the SoundArc. The SoundArc provides an alternative wearing option for patients that may otherwise be discouraged by the aesthetics and usability of the Softband device. GOV IDENTIFIER: NCT03333577.


Assuntos
Auxiliares de Audição , Perda Auditiva , Percepção da Fala , Humanos , Criança , Pré-Escolar , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/terapia , Audiometria , Condução Óssea
17.
World Neurosurg ; 185: e549-e554, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38382763

RESUMO

OBJECTIVE: This study aims to determine the prevalence of vestibular schwannoma (VS) among patients presenting with sudden hearing loss (SHL) and to characterize the clinical features of individuals diagnosed with both VS and SHL. METHODS: We conducted an observational retrospective review at a tertiary referral center, spanning a 30-year period, focusing on patients diagnosed with SHL where VS was confirmed as the underlying cause. We included patients meeting these criteria while excluding those lacking imaging or with a pre-existing diagnosis of VS. We evaluated the audiological characteristics at the time of diagnosis and assessed clinical outcomes following treatment. RESULTS: Among the 403 patients presenting with SHL during the study period, 9 (2.2%) were diagnosed with VS, aged between 25 and 72 years. Although audiometric profiles varied, high-frequency hearing loss predominated, mostly categorized as mild to moderate. Six patients (66%) had Koos grade I-II schwannomas. Only 2 patients achieved complete hearing recovery post-treatment, while 4 showed no improvement. CONCLUSIONS: VS is a rare etiology of SHL, accounting for slightly over 2% of cases. Its symptomatology, severity, and audiometric patterns do not significantly differ from SHL caused by other factors. Tumor size does not correlate with hearing characteristics. Treatment modalities resemble those for other SHL cases, and hearing improvement does not obviate the necessity for follow-up magnetic resonance imaging (MRI) scans.


Assuntos
Perda Auditiva Súbita , Neuroma Acústico , Humanos , Neuroma Acústico/complicações , Neuroma Acústico/diagnóstico por imagem , Pessoa de Meia-Idade , Feminino , Masculino , Adulto , Perda Auditiva Súbita/etiologia , Idoso , Estudos Retrospectivos , Audiometria
18.
Am J Otolaryngol ; 45(3): 104199, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38183921

RESUMO

PURPOSE: The relationship between specific external ear anomalies (EEA) and hearing loss has been previously described. However, there is no literature regarding the appropriate evaluation of patients with EEA by audiology or otolaryngology. The objective of this study was to determine the incidence of audiologic or otolaryngologic evaluation of patients with EEA. MATERIALS AND METHODS: A retrospective review of charts was conducted following approval from the institutional review board at Boston Medical Center. Charts of patients younger than 18 years old with EEA, identified using International Classification of Diseases (ICD)-9 codes 380-380.99, 744, and 744.4 and ICD-10 codes H61.90-92, Q16.0-16.9, Q17.0-17.9, Q18.0-18.2, from January 2012 to January 2019 were reviewed. Primary variables included incidence of audiologic and otolaryngologic evaluation, newborn hearing screen and audiometry results, and completion of surgical intervention. Binary logistic regressions were conducted for each group for diagnostic, procedural, and demographic characteristics. RESULTS: A total of 723 patients were diagnosed with EEA from January 2012 to January 2019. Of these patients, 327 (45.2 %) were evaluated by audiology and 327 (45.2 %) were evaluated by otolaryngology. Of the 364 patients who obtained audiograms, 63 (17.3 %) demonstrated hearing loss. Surgical procedures were performed on 119 (16.5 %) patients, with the most common procedure being excision of the EEA (n = 79, 66.4 %). A total of 468 patients had a documented newborn hearing screen. Failure of newborn hearing screen and presence of microtia were associated with increased otolaryngologic and audiologic evaluation. CONCLUSIONS: A majority of patients with EEAs do not obtain audiologic or otolaryngologic evaluation.


Assuntos
Orelha Externa , Humanos , Estudos Retrospectivos , Masculino , Feminino , Incidência , Criança , Adolescente , Pré-Escolar , Orelha Externa/anormalidades , Lactente , Recém-Nascido , Perda Auditiva/epidemiologia , Perda Auditiva/diagnóstico , Audiometria/métodos , Audiologia , Triagem Neonatal/métodos
19.
Eur Arch Otorhinolaryngol ; 281(7): 3443-3452, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38219247

RESUMO

PURPOSE: To compare the hearing results and clinical safety of patients undergoing stapes surgery with conventional technique and diode laser. METHODS: Retrospective observational study, which included patients treated with primary stapes surgery performed between January 2009 and January 2020. Three audiometric measurements (PTA, GAP and SDS) were evaluated as main results, evaluated by analysis of covariance (controlling the preoperative value). Intraoperative and postoperative complications were also analyzed. Outcomes were measured 6 months (± 1 month) after surgery. RESULTS: 153 cases were included, 97 operated with conventional technique and 56 with laser technique. Postoperative GAP ≤ 10 dB was obtained in 85.6% of the total sample, 82.5% in the conventional technique and 91.1% in the laser technique. Analysis of covariance showed no significant differences in the three surgery outcomes between the two groups (PTA, p = 0.277; GAP, p = 0.509 and SDS, p = 0.530). Regarding surgical complications, sensorineural damage was higher in the conventional technique group (p = 0.05). On the other hand, there were four cases of facial paresis, all in the laser group, three of them with the 980 nm laser. CONCLUSIONS: Stapedotomy offered a high percentage of hearing success in the two groups studied. There were no significant differences in audiometric result, but there was a differential presentation of complications, being more frequent sensorineural hearing loss in the conventional technique group and facial paresis in the laser group.


Assuntos
Lasers Semicondutores , Otosclerose , Complicações Pós-Operatórias , Cirurgia do Estribo , Humanos , Cirurgia do Estribo/métodos , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Lasers Semicondutores/uso terapêutico , Adulto , Otosclerose/cirurgia , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Idoso , Terapia a Laser/métodos , Audiometria
20.
Ear Hear ; 45(2): 486-498, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38178308

RESUMO

OBJECTIVES: Audiometric testing typically does not include frequencies above 8 kHz. However, recent research suggests that extended high-frequency (EHF) sensitivity could affect hearing in natural communication environments. Clinical assessment of hearing often employs pure tones and frequency-modulated (FM) tones interchangeably regardless of frequency. The present study was designed to evaluate how the stimulus chosen to measure EHF thresholds affects estimates of hearing sensitivity. DESIGN: The first experiment used standard audiometric procedures to measure 8- and 16-kHz thresholds for 5- to 28-year olds with normal hearing in the standard audiometric range (250 to 8000 Hz). Stimuli were steady tones, pulsed tones, and FM tones. The second experiment tested 18- to 28-year olds with normal hearing in the standard audiometric range using psychophysical procedures to evaluate how changes in sensitivity as a function of frequency affect detection of stimuli that differ with respect to bandwidth, including bands of noise. Thresholds were measured using steady tones, pulsed tones, FM tones, narrow bands of noise, and one-third-octave bands of noise at a range of center frequencies in one ear. RESULTS: In experiment 1, thresholds improved with increasing age at 8 kHz and worsened with increasing age at 16 kHz. Thresholds for individual participants were relatively similar for steady, pulsed, and FM tones at 8 kHz. At 16 kHz, mean thresholds were approximately 5 dB lower for FM tones than for steady or pulsed tones. This stimulus effect did not differ as a function of age. Experiment 2 replicated this greater stimulus effect at 16 kHz than at 8 kHz and showed that the slope of the audibility curve accounted for these effects. CONCLUSIONS: Contrary to prior expectations, there was no evidence that the choice of stimulus type affected school-age children more than adults. For individual participants, audiometric thresholds at 16 kHz were as much as 20 dB lower for FM tones than for steady tones. Threshold differences across stimuli at 16 kHz were predicted by differences in audibility across frequency, which can vary markedly between listeners. These results highlight the importance of considering spectral width of the stimulus used to evaluate EHF thresholds.


Assuntos
Audiometria , Audição , Adulto , Criança , Humanos , Adolescente , Limiar Auditivo , Audiometria/métodos , Ruído , Testes Auditivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...