1.
Pro Fono ; 20(1): 19-24, 2008.
Artigo em Português | MEDLINE | ID: mdl-18408859

RESUMO

BACKGROUND: temporal auditory processing is defined as the perception of sound or of sound alteration within a restricted time interval and is considered a fundamental ability for the auditory perception of verbal and non verbal sounds, for the perception of music, rhythm, periodicity and in the discrimination of pitch, duration and of phonemes. AIM: to compare the performance of normal Brazilian adults in two temporal resolution tests: the Gaps-in-Noise Test (GIN) and the Random Gap Detection Test (RGDT), and to analyze potential differences of performance in these two tests. METHOD: twenty-five college students with normal hearing (11 males and 14 females) and no history of educational, neurological and/or language problems, underwent the GIN and RGDT at 40dB SL. RESULTS: statistically significant gender effects for both tests were found, with female participants showing poorer performance on both temporal processing tests. In addition, a comparative analysis of the results obtained in the GIN and RGDT revealed significant differences in the threshold measures derived for these two tests. In general, significantly better gap detection thresholds were observed for both male and female participants on the GIN test when compared to the results obtained for the RGDT. CONCLUSION: male participants presented better performances on both RGDT and GIN, when compared to the females. There were no differences in performance between right and left ears on the GIN test. Participants of the present investigation, males and females, performed better on the GIN when compared to the RGDT. The GIN presented advantages over the RGDT, not only in terms of clinical validity and sensibility, but also in terms of application and scoring.


Assuntos
Audiometria/métodos , Doenças Auditivas Centrais/diagnóstico , Percepção Auditiva/fisiologia , Limiar Auditivo/fisiologia , Estimulação Acústica , Adolescente , Adulto , Audiometria/normas , Audiometria de Tons Puros/normas , Brasil , Feminino , Humanos , Percepção Sonora/fisiologia , Masculino , Ruído , Tempo de Reação , Sensibilidade e Especificidade , Fatores Sexuais , Percepção da Fala/fisiologia , Adulto Jovem
2.
Pró-fono ; Pró-fono;20(1): 19-24, jan.-mar. 2008. tab
Artigo em Português | LILACS | ID: lil-480036

RESUMO

TEMA: o processamento auditivo temporal se refere a percepção de um evento sonoro ou de uma alteração no mesmo, dentro de um intervalo definido de tempo e é considerado uma habilidade fundamental na percepção auditiva de sons verbais e não verbais, na percepção de música, ritmo e pontuação e na discriminação de pitch, de duração e de fonemas. OBJETIVO: realizar um estudo comparativo do desempenho de adultos jovens normais nos testes de resolução temporal, Random Gap Detection Test (RGDT) e Gaps-in-Noise (GIN) e analisar diferenças entre esses dois métodos de avaliação. MÉTODO: 25 universitários, 11 homens e 14 mulheres, com audição normal e sem histórico de alterações educacionais, neurológicas e/ou linguagem, foram submetidos ao RGDT e ao GIN, a 40dB NS. RESULTADO: observou-se diferença estatisticamente significante entre os sexos sendo que as mulheres apresentaram pior desempenho nos dois testes. No estudo comparativo dos resultados do RGDT e GIN, observaram-se diferenças significativas no desempenho da amostra. De maneira geral, os limiares de detecção de gap no teste GIN foram melhores do que os limiares obtidos no RGDT. CONCLUSÃO: o sexo masculino teve melhor desempenho tanto no teste RGDT quanto no GIN, quando comparado ao feminino. Além disso, não houve diferença significante nas repostas do GIN nas orelhas direita e esquerda. Os sujeitos deste estudo tiveram melhor desempenho no teste GIN, quando comparado ao RGDT, tanto no sexo masculino quanto no feminino. Portanto, o teste GIN apresentou vantagens sobre o RGDT não apenas quanto à sua validade e sensibilidade, mas também com relação a sua aplicação e correção dos resultados.


BACKGROUND: temporal auditory processing is defined as the perception of sound or of sound alteration within a restricted time interval and is considered a fundamental ability for the auditory perception of verbal and non verbal sounds, for the perception of music, rhythm, periodicity and in the discrimination of pitch, duration and of phonemes. AIM: to compare the performance of normal Brazilian adults in two temporal resolution tests: the Gaps-in-Noise Test (GIN) and the Random Gap Detection Test (RGDT), and to analyze potential differences of performance in these two tests. METHOD: twenty-five college students with normal hearing (11 males and 14 females) and no history of educational, neurological and/or language problems, underwent the GIN and RGDT at 40dB SL. RESULTS: statistically significant gender effects for both tests were found, with female participants showing poorer performance on both temporal processing tests. In addition, a comparative analysis of the results obtained in the GIN and RGDT revealed significant differences in the threshold measures derived for these two tests. In general, significantly better gap detection thresholds were observed for both male and female participants on the GIN test when compared to the results obtained for the RGDT. CONCLUSION: male participants presented better performances on both RGDT and GIN, when compared to the females. There were no differences in performance between right and left ears on the GIN test. Participants of the present investigation, males and females, performed better on the GIN when compared to the RGDT. The GIN presented advantages over the RGDT, not only in terms of clinical validity and sensibility, but also in terms of application and scoring.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Audiometria/métodos , Doenças Auditivas Centrais/diagnóstico , Percepção Auditiva/fisiologia , Limiar Auditivo/fisiologia , Estimulação Acústica , Audiometria de Tons Puros/normas , Audiometria/normas , Brasil , Percepção Sonora/fisiologia , Ruído , Tempo de Reação , Sensibilidade e Especificidade , Fatores Sexuais , Percepção da Fala/fisiologia , Adulto Jovem
3.
Pro Fono ; 18(1): 49-56, 2006.
Artigo em Português | MEDLINE | ID: mdl-16625871

RESUMO

BACKGROUND: It has been suggested that the function of the medial olivocochlear system (MOCS) can be evaluated by the suppression effect of the transient evoked otoacoustic emission (TEOAE). The competitive noise has an inhibitory effect on the functioning of the outer hair-cell, reducing the level of otoacoustic emissions. Despite the fact that there is no postnatal growth of the cochlea, middle ear growth and auditory processing development continue after birth. AIM: To analyze age-related changes of MOCS using the TEOAE suppression in healthy infants. METHOD: 25 full-term infants with no risk factors for hearing loss were evaluated in two moments: at birth and at the age of six months. At both ages TEOAE were recorded in the "Quickscreen" mode, nonlinear stimulation at 78dB peSPL, for both ears, with and without contralateral noise presented at 60dB SPL. RESULTS: The data analyses, using ANOVA, revealed significant contralateral suppression of otoacoustic emissions in both groups, but the TEOAE levels and the amount of TEOAE contralateral suppression were smaller at six-month of age when compared to the neonatal period (p < 0.01). The TEOAE suppression effect for neonatals was 2.81dB (+/- 0.19dB) and at the age of six months was 1.41dB (+/- 0.29dB). CONCLUSION: The amount of TEOAE suppression decreased from birth to six months of age. The association between contralateral acoustic stimulation and a commercially available rapid TEOAE measurement system enables a non-invasive monitoring of the auditory efferent mechanism and seems to be clinically feasible to evaluate cochlear status and auditory efferent function development in infants at risk.


Assuntos
Audiometria/métodos , Cóclea/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Núcleo Olivar/fisiologia , Emissões Otoacústicas Espontâneas , Estimulação Acústica/métodos , Estimulação Acústica/normas , Distribuição por Idade , Análise de Variância , Audiometria/normas , Feminino , Perda Auditiva Provocada por Ruído/diagnóstico , Humanos , Lactente , Recém-Nascido , Masculino , Distribuição por Sexo
4.
Pró-fono ; Pró-fono;18(1): 49-56, jan.-abr. 2006. tab, graf
Artigo em Português | LILACS | ID: lil-427252

RESUMO

TEMA: tem sido sugerido que a função do sistema olivo coclear medial (SOCM) pode ser avaliada pelo efeito de supressão das emissões otoacústicas por transientes (EOAT). O ruído competitivo tem um efeito inibitório no funcionamento das células ciliadas externas reduzindo o nível das emissões otoacústicas. Apesar de não haver crescimento pós natal da cóclea, o crescimento da orelha média e o desenvolvimento do processamento auditivo continuam após o nascimento. OBJETIVO: analisar as mudanças no SOCM relacionadas à idade por meio da supressão das EOAT em lactentes saudáveis. MÉTODO: 25 lactentes a termo sem indicadores de risco auditivo foram avaliados em dois momentos: ao nascimento e no sexto mês de vida. Nas duas idades as EOAT foram captadas no modo "Quickscreen", estímulo clique não linear a 78dB peNPS, nas duas orelhas, com e sem ruído contralateral apresentado a 60dB NPS. RESULTADOS: a análise dos dados por meio da ANOVA revelou significante supressão contralateral das EOAT em ambos grupos, porém tanto os níveis das EOAT quanto a magnitude da supressão contralateral das EOAT foram menores no sexto mês de vida quando comparados com a fase neonatal (p<0,01). O efeito de supressão das EOAT no período neonatal foi 2,81dB (± 0,19dB) e no sexto mês de vida foi 1,41dB (± 0,29dB). CONCLUSAO: a magnitude da supressão das EOAT diminuiu do nascimento ao sexto mês de idade. A associação entre a estimulação acústica contralateral e um sistema, disponível comercialmente, rápido na medida das EOAT possibilita o monitoramento não invasivo dos mecanismos eferentes auditivos e parece ser clinicamente promissor na avaliação do estado coclear e do desenvolvimento da função eferente auditiva de lactentes de risco.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Audiometria/métodos , Cóclea/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Perda Auditiva Provocada por Ruído/diagnóstico , Emissões Otoacústicas Espontâneas , Núcleo Olivar/fisiologia , Distribuição por Idade , Análise de Variância , Estimulação Acústica/métodos , Estimulação Acústica/normas , Audiometria/normas , Distribuição por Sexo
5.
An. otorrinolaringol. Perú ; 8(3): 257-261, dic. 2001. tab
Artigo em Espanhol | LIPECS | ID: biblio-1106034

RESUMO

El objetivo de este trabajo fue determinar los valores de los umbrales tonales de altas frecuencias por sexo y edad, establecer el desvío estándar de los mismos y conseguir así un patrón de normalidad. Para llevar a cabo la investigación, se evaluaron 70 pacientes (140 oídos) de ambos sexos, en edades comprendidas entre 20 y 60 años, obteniendo como resultado umbrales reproducibles para un mis sujeto. Se observa un deterioro con la edad, más notable a partir de los 30-40 años, con predominio del sexo masculino. Las curvas de referencia obtenidas para cada década son de gran utilidad para predecir con mayor anticipación el año coclear, y es por ello que consideramos a la audiometría de altas frecuencias como una válida extensión de la audiometría convencional.


The object of this research was to determine high frequency tone threshold values, by sex and age, in order to establish the standard deviation, and then, obtain a normality pattern. To carry out this investigation 70 patients were measured (140 ears) from both sexes, between 20 and 60 years of age, obtaining as a result reproducible thresholds for the same subject. It was observed a decline with age, more remarkable from 30-40ears, mainly in male sex. The reference curves of each decade have been of great utility to predict with higher anticipation the cochlear damage, therefore we consider high frequency audiometry as a valid extension of the conventional one.


Assuntos
Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Audiometria/métodos , Audiometria/normas
6.
Rev. bras. saúde ocup ; 17(65): 43-54, jan.-mar. 1989. tab, ilus
Artigo em Português | LILACS | ID: lil-71613

RESUMO

A surdez profissional é um dos maiores problemas de saúde ocupacional entre os trabalhadores, notadamente os metalúrgicos. O presente trabalho aborda a questäo em seus aspectos médico-jurídicos, afirmando que os critérios legais vigentes para a interpretaçäo dos exames audiométricos dificultam a caracterizaçäo dos estágios evolutivos da surdez profissional, bem como a conduta do médico do trabalho, da empresa, do sindicato e da fiscalizaçäo


Assuntos
Humanos , Audiometria/normas , Perda Auditiva Provocada por Ruído/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA