Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1605: 360358, 2019 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-31337499

RESUMO

The chiral separation of baclofen (Bac) was obtained by nano-liquid chromatography tandem mass spectrometry (nano-LC-MS/MS) using a 100 µm I.D. fused silica capillary column packed with silica particles chemically modified with vancomycin. Various experimental parameters, such as composition (buffer concentration, water content, organic modifier) and pH of the mobile phase and sample solvent were investigated for method optimization. In order to increase the sensitivity an on-column focusing procedure was applied. Acceptable separation of Bac enantiomers was obtained in less than 11 min eluting in isocratic mode, with 90:10 MeOH/water (v/v) containing 10 mM ammonium acetate at pH 4.5. These optimized experimental conditions were applied to the analysis of human plasma samples spiked with racemic mixture of Bac. The use of a Buckypaper disc as sorbent membrane allows one to recover both enantiomers with yields ≥ 65%. The method was fully validated, following the identification criteria of the European Commission Decision 2002/657/EC.


Assuntos
Baclofeno/isolamento & purificação , Cromatografia Líquida/métodos , Nanopartículas/química , Dióxido de Silício/química , Vancomicina/química , Baclofeno/sangue , Baclofeno/química , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Extração em Fase Sólida , Estereoisomerismo , Espectrometria de Massas em Tandem
2.
Biomed Chromatogr ; 31(1)2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27591736

RESUMO

Baclofen is a commonly used racemic drug and has a simple chemical structure in terms of the presence of only one stereogenic center. Since the desirable pharmacological effect is in only one enantiomer, several possibilities exist for the other enantiomer for evaluation of the disposition of the racemic mixture of the drug. This calls for the development of enantioselective analytical methodology. This review summarizes and evaluates different methods of enantioseparation of (RS)-baclofen using both direct and indirect approaches, application of certain chiral reagents and chiral stationary phases (though very expensive). Methods of separation of diastereomers of (RS)-baclofen prepared with different chiral derivatizing reagents (under microwave irradiation at ease and in less time) on reversed-phase achiral columns or via a ligand exchange approach providing high-sensitivity detection by the relatively less expensive methods of TLC and HPLC are discussed. The methods may be helpful for determination of enantiomers in biological samples and in pharmaceutical formulations for control of enantiomeric purity and can be practiced both in analytical laboratories and industry for routine analysis and R&D activities.


Assuntos
Baclofeno/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Agonistas dos Receptores de GABA-B/isolamento & purificação , Relaxantes Musculares Centrais/isolamento & purificação , Baclofeno/química , Agonistas dos Receptores de GABA-B/química , Indicadores e Reagentes , Relaxantes Musculares Centrais/química , Estereoisomerismo
3.
Biomed Chromatogr ; 30(11): 1728-1732, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27105592

RESUMO

Separation of racemic mixture of (RS)-bupropion, (RS)-baclofen and (RS)-etodolac, commonly marketed racemic drugs, has been achieved by modifying the conventional ligand exchange approach. The Cu(II) complexes were first prepared with a few l-amino acids, namely, l-proline, l-histidine, l-phenylalanine and l-tryptophan, and to these was introduced a mixture of the enantiomer pair of (RS)-bupropion, or (RS)-baclofen or (RS)-etodolac. As a result, formation of a pair of diastereomeric complexes occurred by 'chiral ligand exchange' via the competition between the chelating l-amino acid and each of the two enantiomers from a given pair. The diastereomeric mixture formed in the pre-column process was loaded onto HPLC column. Thus, both the phases during chromatographic separation process were achiral (i.e. neither the stationary phase had any chiral structural feature of its own nor did the mobile phase have any chiral additive). Separation of diastereomers was successful using a C18 column and a binary mixture of MeCN and TEAP buffer of pH 4.0 (60:40, v/v) as mobile phase at a flow rate of 1 mL/min and UV detection at 230 nm for (RS)-Bup, 220 nm for (RS)-Bac and 223 nm for (RS)-Etd. Baseline separation of the two enantiomers was obtained with a resolution of 6.63 in <15 min. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Antidepressivos de Segunda Geração/isolamento & purificação , Baclofeno/isolamento & purificação , Bupropiona/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Inibidores de Ciclo-Oxigenase 2/isolamento & purificação , Etodolac/isolamento & purificação , Relaxantes Musculares Centrais/isolamento & purificação , Aminoácidos/química , Antidepressivos de Segunda Geração/química , Baclofeno/química , Bupropiona/química , Complexos de Coordenação/química , Cobre/química , Inibidores de Ciclo-Oxigenase 2/química , Etodolac/química , Ligantes , Relaxantes Musculares Centrais/química , Estereoisomerismo
4.
Biomed Chromatogr ; 26(6): 743-8, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21989982

RESUMO

Enantioresolution of (R,S)-baclofen was accomplished using a newly synthesized set of three chiral derivatizing reagents (CDRs) having amines [(S)-(-)-α,4-dimethylbenzylamine, (-)-cis-myrtanylamine and (R)-(-)-1-cyclohexylethylamine] as chiral auxiliaries in cyanuric chloride and another set of five CDRs having amino acids (L-Leu, D-Phg, L-Val, L-Met and L-Ala) as chiral auxiliaries. These eight CDRs were used for synthesis of diastereomers of (R,S)-baclofen under microwave irradiation. The diastereomers were separated on a reversed-phase C(18) column using mixtures of methanol with aqueous trifluoroacetic acid with UV detection at 230 nm. Chromatographic data obtained for the two sets of diastereomers were compared among themselves and among the two groups. The method was validated for limit of detection, linearity, accuracy and precision.


Assuntos
Aminas/química , Aminoácidos/química , Baclofeno/química , Cromatografia Líquida de Alta Pressão/métodos , Triazinas/química , Baclofeno/análise , Baclofeno/isolamento & purificação , Limite de Detecção , Análise de Regressão , Reprodutibilidade dos Testes , Estereoisomerismo
5.
Artigo em Inglês | MEDLINE | ID: mdl-18656427

RESUMO

Capillary electrophoresis (CE) coupled to tandem mass spectrometry was applied to the chiral separation of baclofen using sulfobutylether-beta-cyclodextrin chiral selector in partial filling counter current mode. On-line UV detection was simultaneously used. Method optimization was performed by studying the effect of cyclodextrin and BGE concentration as well as sheath liquid composition on analyte migration time and enantiomeric resolution. The cyclodextrin showed stereoselective complexation towards baclofen enantiomers, allowing chiral resolution at low concentration. The CE capillary protrusion from the ESI needle relevantly affected the chiral resolution and the analyte migration time. Complete enantiomeric separation was obtained by using 0.25 M formic acid BGE containing 1.75 mM of chiral selector and water/methanol (30:70, v/v) 3% formic acid as sheath liquid. The method exhibited a LOD of 0.1 microg/mL (racemic concentration) in MS3 product ion scan mode of detection and was applied to the analysis of racemic baclofen in pharmaceutical formulations.


Assuntos
Baclofeno/isolamento & purificação , Eletroforese Capilar/métodos , Espectrometria de Massas em Tandem/métodos , Eletroforese Capilar/instrumentação , Formiatos/química , Preparações Farmacêuticas/química , Sensibilidade e Especificidade , Estereoisomerismo , beta-Ciclodextrinas
6.
Biomed Chromatogr ; 22(8): 906-11, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18512855

RESUMO

A high-performance liquid chromatographic (HPLC) method was developed for chiral assay of baclofen enantiomers in pharmaceutical formulations using an indirect approach. Baclofen enantiomers were derivatized with Marfey's reagent (FDNP-L-Ala-NH2) and its structural variants FDNP-L-Phe-NH2, FDNP-L-Val-NH2, FDNP-L-Leu-NH2 and FDNP-L-Pro-NH2. The resultant diastereomers were separated on RP-TLC [triethylammonium phosphate buffer (pH 4.0, 50 mm)-acetonitrile, 50:50] and on a C18 column using a linear gradient (45 min) of acetonitrile and 0.01% aqueous trifluoroacetic acid (TFA) with UV detection at 340 nm. The differences in the retention times (Delta t R) of diastereomers due to the five chiral reagents were compared. The maximum and minimum difference in retention times between separated diastereomers was for FDNP-L-Leu-NH2 and FDNP-L-Pro-NH2, respectively. The effect of flow rate, acetonitrile content and TFA concentration on resolution was studied. The method was validated for linearity, repeatability, limit of detection and limit of quantification.


Assuntos
Alanina/análogos & derivados , Baclofeno/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Dinitrobenzenos/química , Formas de Dosagem , Agonistas GABAérgicos/isolamento & purificação , Alanina/química , Baclofeno/química , Cromatografia em Camada Fina , Agonistas GABAérgicos/química , Padrões de Referência , Reprodutibilidade dos Testes , Estereoisomerismo
7.
J Sep Sci ; 28(16): 2187-92, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16318216

RESUMO

The enantioseparation of baclofen (4-amino-3-p-chlorophenylbutyric acid) was achieved by CE-LIF with highly sulfated beta-CD (HS-beta-CD) as chiral selector. Naphthalene-2,3-dicarboxaldehyde was used for the derivatization of nonfluorescent baclofen. HS-beta-CD (2%) containing 50 mM borate buffer at pH 9.5 was chosen as the optimal running electrolyte and applied to the analysis of baclofen enantiomers in human plasma. The linearity of calibration curves (R2 > or = 0.998) for R-(-) and S-(+)-baclofen was in the 0.1-2.0 microM concentration range. After a simple ACN-protein precipitation, the LOD of baclofen in plasma sample was found as low as 50 nM.


Assuntos
Baclofeno/isolamento & purificação , Eletroforese Capilar , Fluorometria , beta-Ciclodextrinas , Estranos , Etanol , Humanos , Isomerismo , Lasers , Metanol , Nitrilas , Plasma/química
8.
Electrophoresis ; 26(24): 4774-9, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16278920

RESUMO

Chiral separations of FITC-labeled basic drugs on multichannel microfluidic chips with LIF detector were investigated. A preliminary screening procedure for seven neutral CDs was performed under optimized conditions for chiral separations of three FITC-labeled drugs (baclofen, norfenefrine, and tocainide) on a mono-channel microfluidic chip. According to the results of screening, FITC-baclofen and FITC-norfenefrine as well as two chiral selectors including gamma-CD and dimethyl-beta-CD (DM-beta-CD) were selected as models to perform chiral separations on a two-channel chip. FITC-baclofen enantiomers were separated completely by gamma-CD in one channel, while resolution of FITC-norfenefrine enantiomers was achieved by DM-beta-CD in the other channel in the same run. Furthermore, the feasibility of using one chiral selector to separate multiple chiral samples was studied on a four-channel chip. These results show that multichannel chip has a potential for chiral high-throughput screening.


Assuntos
Eletroforese em Microchip/métodos , Baclofeno/análogos & derivados , Baclofeno/isolamento & purificação , Eletroforese em Microchip/instrumentação , Fluoresceína-5-Isotiocianato/química , Corantes Fluorescentes/química , Octopamina/análogos & derivados , Octopamina/isolamento & purificação , Estereoisomerismo , Tocainide/análogos & derivados , Tocainide/isolamento & purificação , beta-Ciclodextrinas , gama-Ciclodextrinas
9.
Electrophoresis ; 25(7-8): 1111-9, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15095454

RESUMO

Using cyclodextrin-capillary zone electrophoresis (CD-CZE), baseline separation of baclofen, a potent GABA(B) agonist; was achieved. A method for the enantioresolution of this gamma-aminobutyric acid (GABA) and determination of enantiomeric purity was developed using CDs (highly sulfated-CD or highly S-CD) as chiral selectors and capillaries dynamically coated with polyethylene oxide (PEO). Operational parameters, such as the nature and concentration of the chiral selectors, buffer concentration, organic modifiers, and applied voltage, were investigated. The use of charged CDs provides a driving force in the opposite direction of the positively charged baclofen in the running buffer and enantiomeric resolution by inclusion of compounds in the CD cavity. Highly S-beta-CD was found to be the most effective complexing agent, allowing good enantiomeric resolution. The complete resolution was obtained using 25 mM phosphate buffer, pH 2.5, containing 3% w/v highly S-beta-CD at 25 degrees C with aN applied field of 0.40 kV/cm. The apparent association constants of the inclusion complexes were calculated. This optimized method was validated in terms of repeatability and limits of detection (0.13 microg x mL(-1)) and quantification. The migration order was determined.


Assuntos
Baclofeno/isolamento & purificação , Ciclodextrinas/química , Eletroforese Capilar/métodos , Agonistas GABAérgicos/isolamento & purificação , Ácidos Sulfúricos/química , Ácido gama-Aminobutírico/metabolismo , Soluções Tampão , Agonistas GABAérgicos/metabolismo , Ligantes , Sensibilidade e Especificidade
10.
Artigo em Inglês | MEDLINE | ID: mdl-12554140

RESUMO

The method presented here is a high-performance liquid chromatography (HPLC)-UV detection method for the determination of baclofen R-(-)- and S-(+)-enantiomers in human plasma using a chiral separation technique. Baclofen enantiomers were extracted from human plasma with a reversed-phase solid-phase extraction (SPE) cartridge. The extract was then injected onto a HPLC system with a UV detection system set at 220 nm. The separation was achieved by using a 150x4.6 mm, 5 microm Phenomenex chirex 3216 chiral column with a mobile phase consisting of 0.4 mM CuSO(4) in acetonitrile-20 mM sodium acetate (17:83). The calibration curves were linear for both R-(-)- and S-(+)-enantiomers of baclofen in the concentration range of 20-5000 ng/ml. The average regressions were 0.9980 and 0.9991 for R-(-)- and S-(+)-baclofen, respectively. Inter-day precision was 3.3-5.2% for R-(-)-baclofen and 3.5-3.9% for S-(+)-baclofen at a concentration range of 60-4000 ng/ml. Intra-day precisions were 0.6-4.4 and 0.5-3.5% for R-(-)-baclofen and S-(+)-baclofen, respectively. The average extraction recovery was 81.6% for R-(-)-baclofen, 83.0% for S-(+)-baclofen and 94.0% for the internal standard (p-aminobenzoic acid). The limit of quantitation for both R-(-)- and S-(+)-baclofen in human plasma was 20 ng/ml. The method is simple and easy to operate with accuracy and reproducibility and it is suitable for pharmacokinetic studies.


Assuntos
Baclofeno/sangue , Agonistas GABAérgicos/sangue , Baclofeno/isolamento & purificação , Calibragem , Cromatografia Líquida de Alta Pressão , Agonistas GABAérgicos/isolamento & purificação , Humanos , Indicadores e Reagentes , Padrões de Referência , Manejo de Espécimes , Espectrofotometria Ultravioleta , Estereoisomerismo
11.
Artigo em Inglês | MEDLINE | ID: mdl-15954592

RESUMO

Baclofen is chemically (RS)-beta-(aminomethyl)-4-chlorobenzene propanoic acid. It is used in therapy of pain and as a muscle relaxant. Baclofen produces analgesia by increasing the concentration of gamma amino butyric acid (GABA), the major rapid inhibitory transmitter. Both the isomers of baclofen have different therapeutic activity with respect to their interaction to the receptors at the site of action. Lipase from Candida cylindracea has been used as a catalyst for resolving racemic mixtures of numerous drug molecules. The present investigation deals with the racemic resolution of RS-baclofen using lipase from Candida cylindracea and a study of the factors affecting resolution.


Assuntos
Baclofeno/química , Lipase/metabolismo , Baclofeno/isolamento & purificação , Baclofeno/metabolismo , Candida/metabolismo , Catálise , Estereoisomerismo , Especificidade por Substrato , Ácido gama-Aminobutírico
12.
Chirality ; 6(7): 583-9, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7986672

RESUMO

Phaclofen, which is the phosphonic acid analogue of the GABAB agonist (RS)-3-(4-chlorophenyl)-4-aminobutyric acid (baclofen), is a GABAB antagonist. As part of our studies on the structural requirements for activation and blockade of GABAB receptors, we have resolved phaclofen using chiral chromatographic techniques. The absolute stereochemistry of (-)-(R)-phaclofen was established by X-ray crystallographic analysis. (-)-(R)-Phaclofen was shown to inhibit the binding of [3H]-(R)-baclofen to GABAB receptor sites on rat cerebellar membranes (IC50 = 76 +/- 13 microM), whereas (+)-(S)-phaclofen was inactive in this binding assay (IC50 > 1000 microM). (-)-(R)-Phaclofen (200 microM) was equipotent with (RS)-phaclofen (400 microM) in antagonizing the action of baclofen in rat cerebral cortical slices, while (+)-(S)-phaclofen (200 microM) was inactive. The structural similarity of the agonist (R)-baclofen and the antagonist (-)-(R)-phaclofen suggests that these ligands interact with the GABAB receptor sites in a similar manner. Thus, it may be concluded that the different pharmacological effects of these compounds essentially result from the different spatial and proteolytic properties of their acid groups.


Assuntos
Baclofeno/análogos & derivados , Córtex Cerebral/metabolismo , Antagonistas GABAérgicos/química , Antagonistas de Receptores de GABA-B , Animais , Baclofeno/química , Baclofeno/isolamento & purificação , Baclofeno/metabolismo , Baclofeno/farmacologia , Cromatografia Líquida de Alta Pressão , Cristalografia por Raios X/métodos , Antagonistas GABAérgicos/isolamento & purificação , Antagonistas GABAérgicos/farmacologia , Técnicas In Vitro , Modelos Moleculares , Conformação Molecular , Estrutura Molecular , Ratos , Estereoisomerismo , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...