Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Pharm Res ; 37(10): 209, 2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-32995953

RESUMO

PURPOSE: A combined in vitro - in silico methodology was designed to estimate pharmacokinetics of budesonide delivered via dry powder inhaler. METHODS: Particle size distributions from three budesonide DPIs, measured with a Next Generation Impactor and Alberta Idealized Throat, were input into a lung deposition model to predict regional deposition. Subsequent systemic exposure was estimated using a pharmacokinetic model that incorporated Nernst-Brunner dissolution in the conducting airways to predict the net influence of dissolution, mucociliary clearance, and absorption. RESULTS: DPIs demonstrated significant in vitro differences in deposition, resulting in large differences in simulated regional deposition in the central conducting airways and the alveolar region. Similar but low deposition in the small conducting airways was observed with each DPI. Pharmacokinetic predictions showed good agreement with in vivo data from the literature. Peak systemic concentration was tied primarily to the alveolar dose, while the area under the curve was more dependent on the total lung dose. Tracheobronchial deposition was poorly correlated with pharmacokinetic data. CONCLUSIONS: Combination of realistic in vitro experiments, lung deposition modeling, and pharmacokinetic modeling was shown to provide reasonable estimation of in vivo systemic exposure from DPIs. Such combined approaches are useful in the development of orally inhaled drug products.


Assuntos
Broncodilatadores/administração & dosagem , Broncodilatadores/farmacocinética , Budesonida/administração & dosagem , Budesonida/farmacocinética , Inaladores de Pó Seco/instrumentação , Administração por Inalação , Broncodilatadores/sangue , Budesonida/sangue , Simulação por Computador , Desenho de Equipamento , Humanos , Técnicas In Vitro , Pulmão/fisiologia , Modelos Biológicos , Tamanho da Partícula , Faringe , Equivalência Terapêutica
2.
Pediatr Res ; 88(4): 629-636, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32006953

RESUMO

BACKGROUND: Initial trials of lung-targeted budesonide (0.25 mg/kg) in surfactant to prevent bronchopulmonary dysplasia (BPD) in premature infants have shown benefit; however, the optimal safe dose is unknown. METHODS: Dose-escalation study of budesonide (0.025, 0.05, 0.10 mg/kg) in calfactatant in extremely low gestational age neonates (ELGANs) requiring intubation at 3-14 days. Tracheal aspirate (TA) cytokines, blood budesonide concentrations, and untargeted blood metabolomics were measured. Outcomes were compared with matched infants receiving surfactant in the Trial Of Late SURFactant (TOLSURF). RESULTS: Twenty-four infants with mean gestational age 25.0 weeks and 743 g birth weight requiring mechanical ventilation were enrolled at mean age 6 days. Budesonide was detected in the blood of all infants with a half-life of 3.4 h. Of 11 infants with elevated TA cytokine levels at baseline, treatment was associated with sustained decrease (mean 65%) at all three dosing levels. There were time- and dose-dependent decreases in blood cortisol concentrations and changes in total blood metabolites. Respiratory outcomes did not differ from the historic controls. CONCLUSIONS: Budesonide/surfactant had no clinical respiratory benefit at any dosing levels for intubated ELGANs. One-tenth the dose used in previous trials had minimal systemic metabolic effects and appeared effective for lung-targeted anti-inflammatory action.


Assuntos
Displasia Broncopulmonar/tratamento farmacológico , Budesonida/administração & dosagem , Tensoativos/administração & dosagem , Anti-Inflamatórios/farmacologia , Peso ao Nascer , Budesonida/sangue , Citocinas/metabolismo , Relação Dose-Resposta a Droga , Feminino , Humanos , Hidrocortisona/sangue , Lactente Extremamente Prematuro , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Risco , Resultado do Tratamento
3.
Pulm Pharmacol Ther ; 60: 101873, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31841699

RESUMO

BACKGROUND: Budesonide/glycopyrrolate/formoterol fumarate metered dose inhaler (BGF MDI), formulated using co-suspension delivery technology, is a triple fixed-dose combination in late-stage clinical development for chronic obstructive pulmonary disease (COPD). METHODS: We conducted two studies to characterize the pharmacokinetic (PK) profile of BGF MDI in patients with COPD: (i) a phase I, open-label, single and chronic (7-day) dosing study (NCT03250182) with one treatment arm (BGF MDI 320/18/9.6 µg); and (ii) a PK sub-study of KRONOS (NCT02497001), a phase III, randomized, double-blind study in which patients received 24 weeks' treatment with BGF MDI 320/18/9.6 µg, glycopyrrolate/formoterol fumarate (GFF) MDI 18/9.6 µg, budesonide/formoterol fumarate (BFF) MDI 320/9.6 µg, or budesonide/formoterol fumarate dry powder inhaler (BUD/FORM DPI) 320/9 µg. PK parameters in both studies included maximum observed plasma concentration (Cmax) and area under the plasma concentration-time curve from 0 to 12h (AUC0-12). RESULTS: In the phase I PK study (30 patients), budesonide and glycopyrronium Cmax were comparable after single and chronic dosing of BGF MDI (accumulation ratio [RAC] 95% and 107%, respectively) whereas Cmax for formoterol was slightly higher after chronic dosing (RAC 116%). AUC0-12 for budesonide, glycopyrronium, and formoterol were higher following chronic versus single dosing, with an RAC of 126%, 179%, and 143%, respectively. After 7 days' dosing, AUC0-12 and Cmax for all three components of BGF MDI were similar to those in the KRONOS PK sub-study (202 patients) at Week 24. In the latter sub-study, Cmax and AUC0-12 at Week 24 were generally comparable across treatments for budesonide (geometric mean ratios [GMR] of 96%-109% for BGF MDI vs BFF MDI or BUD/FORM DPI), glycopyrronium (GMR of 88%-100% for BGF MDI vs GFF MDI), and formoterol (GMR of 80%-113% for BGF MDI vs GFF MDI or BFF MDI). CONCLUSIONS: Steady-state PK parameters of budesonide, glycopyrronium, and formoterol were similar after 7 days' dosing in the phase I PK study and after 24 weeks in the KRONOS PK sub-study. Systemic exposure to budesonide, glycopyrronium, and formoterol was generally comparable across treatments in the KRONOS PK sub-study, suggesting no meaningful drug-drug or within-formulation PK interactions.


Assuntos
Broncodilatadores/administração & dosagem , Budesonida/farmacocinética , Sistemas de Liberação de Medicamentos/métodos , Fumarato de Formoterol/farmacocinética , Glicopirrolato/farmacocinética , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Administração por Inalação , Adulto , Idoso , Idoso de 80 Anos ou mais , Broncodilatadores/sangue , Broncodilatadores/farmacocinética , Budesonida/administração & dosagem , Budesonida/sangue , Método Duplo-Cego , Combinação de Medicamentos , Feminino , Fumarato de Formoterol/administração & dosagem , Fumarato de Formoterol/sangue , Glicopirrolato/administração & dosagem , Glicopirrolato/sangue , Humanos , Masculino , Inaladores Dosimetrados , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/metabolismo , Distribuição Aleatória
4.
J Pharm Biomed Anal ; 179: 112980, 2020 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-31744668

RESUMO

In this study, a simple, rapid and sensitive LC-MS/MS analytical method for simultaneous determination of six glucocorticoids including 21-hydroxy deflazacort (21-OH DFZ), prednisolone (PNL), betamethasone (BET), beclomethasone (BEC), triamcinolone acetonide (TCA), budesonide (BUD) in nude mice plasma was developed and validated. Using testosterone as internal standard, the plasma samples were prepared by precipitation with acetonitrile and separated using an ACQUITY UPLC BEH C18 column (100 mm × 2.1 mm, 1.7 µm) with a mobile phase composed of acetonitrile and 0.1 % (v/v) formic acid aqueous solution by gradient elution at a flow rate of 0.3 mL/min. Quantitation was performed on a triple quadruple tandem mass spectrometer by multiple reaction monitoring in positive electrospray ionization mode. Calibration curves were developed over the range of 1-400 ng/mL for TCA, 5-2000 ng/mL for 21-OH DFZ, BET, BEC as well as BUD, and 10-2000 ng/mL for PNL. The accuracy, precision, matrix effect, recovery and stability were validated to be within acceptable criteria. The method was successfully applied to a preclinical pharmacokinetic (PK) study of the six GCs on female nude mice after a single oral dose of 1 mg/kg. The PK profiles of all the six GCs were described by two-compartment model with first-order absorption rate.


Assuntos
Cromatografia Líquida/métodos , Glucocorticoides/farmacocinética , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Beclometasona/sangue , Beclometasona/farmacocinética , Betametasona , Budesonida/sangue , Budesonida/farmacocinética , Calibragem , Feminino , Glucocorticoides/sangue , Camundongos , Camundongos Nus , Modelos Biológicos , Prednisolona , Pregnenodionas/sangue , Pregnenodionas/farmacocinética , Reprodutibilidade dos Testes , Triancinolona Acetonida/sangue , Triancinolona Acetonida/farmacocinética
5.
AAPS J ; 21(4): 53, 2019 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-30993489

RESUMO

The study goal was to evaluate the transplacental transfer of two corticosteroids, budesonide (BUD) and fluticasone propionate (FP), in pregnant mice and investigate whether P-glycoprotein (P-gp) might be involved in reducing BUD transplacental transfer. Pregnant mice (N = 18) received intravenously either low (104.9 µg/kg) or high (1049 µg/kg) dose of [3H]-BUD or a high dose of [3H]-FP (1590 µg/kg). In a separate experiment, pregnant mice (N = 12) received subcutaneously either the P-gp inhibitor zosuquidar (20 mg/kg) or vehicle, followed by an intravenous infusion of [3H]-BUD (104.9 µg/kg). Total and free (protein unbound) corticosteroid concentrations were determined in plasma, brain, fetus, placenta, kidney, and liver. The ratios of free BUD concentrations in fetus versus plasma K(fetus, plasma, u, u) 0.42 ± 0.17 (mean ± SD) for low-dose and 0.38 ± 0.18 for high-dose BUD were significantly different from K = 1 (P < 0.05), contrary to 0.87 ± 0.25 for FP, which was moreover significantly higher than that for matching high-dose BUD (P < 0.01). The BUD brain/plasma ratio was also significantly smaller than K = 1, while these ratios for other tissues were close to 1. In the presence of the P-gp inhibitor, K(fetus, plasma, u, u) for BUD (0.59 ± 0.16) was significantly increased over vehicle treatment (0.31 ± 0.10; P < 0.01). This is the first in vivo study demonstrating that transplacental transfer of BUD is significantly lower than FP's transfer and that placental P-gp may be involved in reducing the fetal exposure to BUD. The study provides a mechanistic rationale for BUD's use in pregnancy.


Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Budesonida/farmacocinética , Feto/metabolismo , Fluticasona/farmacocinética , Placenta/metabolismo , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/antagonistas & inibidores , Animais , Budesonida/administração & dosagem , Budesonida/sangue , Relação Dose-Resposta a Droga , Feminino , Fluticasona/administração & dosagem , Fluticasona/sangue , Injeções Intravenosas , Exposição Materna , Camundongos Endogâmicos C57BL , Especificidade de Órgãos , Gravidez , Especificidade por Substrato
6.
J Pharm Biomed Anal ; 167: 7-14, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30738243

RESUMO

Budesonide is a potential therapeutic option for the prevention of bronchopulmonary dysplasia in mechanically ventilated premature neonates. The dose and concentrations of budesonide that drive effective prophylaxis are unknown, due in part to the difficulty in obtaining serial blood samples from this fragile population. Of primary concern is the limited total blood volume available for collection for the purposes of a pharmacokinetic study. Dried blood spots (DBS), which require the collection of <200 µL whole blood to fill an entire card, are an attractive low-blood volume alternative to traditional venipuncture sampling. We describe a simple and sensitive method for determining budesonide concentrations in DBS using an ultra-high-performance liquid chromatography - tandem mass spectrometry assay. Budesonide was liberated from a single 6 mm punch using a basified methyl tert-butyl ether extraction procedure. The assay was determined to be accurate and precise in the dynamic range of 1 to 50 ng/mL. The validated assay was then successfully applied to DBS collected as part of a multi-center, dose-escalation study of budesonide administered in surfactant via intra-tracheal instillation to premature neonates between 23 and 28 weeks gestational age. These findings show that DBS are a useful technique for collecting pharmacokinetic samples in premature neonates and other pediatric populations.


Assuntos
Budesonida/sangue , Teste em Amostras de Sangue Seco/métodos , Monitoramento de Medicamentos/métodos , Lactente Extremamente Prematuro/sangue , Bioensaio , Displasia Broncopulmonar/sangue , Displasia Broncopulmonar/prevenção & controle , Calibragem , Cromatografia Líquida de Alta Pressão , Teste em Amostras de Sangue Seco/instrumentação , Monitoramento de Medicamentos/instrumentação , Idade Gestacional , Humanos , Recém-Nascido , Limite de Detecção , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
7.
Anal Chim Acta ; 1048: 132-142, 2019 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-30598143

RESUMO

Microwave reactors with on-line controlled reaction conditions have been recently innovated to improve reaction kinetics and reproducibility. Herein, a modern microwave reactor was dedicated to develop a new, sensitive and reproducible approach for trace analysis of budesonide (BUD) in human plasma. The method was based on fast microwave reaction of BUD with dansyl hydrazine (DNS-HZ) reagent under controlled conditions coupled with high-performance liquid chromatography (HPLC)-fluorescence detection. The microwave irradiation and dansylation conditions were optimized for the best sensitivity and selectivity. The controlled microwave derivatization reaction (CMDR) decreased the reaction time, amplified the reaction yield and enhanced product purities by reducing the unwanted side reactions. The chromatographic separation was attained by isocratic elution on reversed phase column via a mobile phase consisted of methanol and phosphate buffer (10 mM, pH 7.0) at ratio 80:20 (v/v). The fluorescence detector was set at 500 nm after excitation at 330 nm. Betamethasone dipropionate (BDP) was used as an internal standard. CMDR-HPLC method validation was performed in agreement with bioanalytical method validation guidelines by the US food and drug administration (US-FDA). The obtained linearity range was 0.2-100 ng mL-1 with correlation coefficient 0.9991 and the lower limit of quantitation (LLOQ) in human plasma was 0.21 ng mL-1. The developed CMDR -HPLC method was applied successfully for assessment of plasma levels of BUD in allergic rhinitis patients after intranasal administration of the micronized BUD.


Assuntos
Budesonida/sangue , Budesonida/química , Cromatografia Líquida de Alta Pressão/métodos , Compostos de Dansil/química , Corantes Fluorescentes/química , Hidrazinas/química , Administração Intranasal , Adulto , Budesonida/administração & dosagem , Budesonida/efeitos da radiação , Compostos de Dansil/efeitos da radiação , Fluorescência , Corantes Fluorescentes/efeitos da radiação , Humanos , Hidrazinas/efeitos da radiação , Limite de Detecção , Masculino , Micro-Ondas , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
8.
Pulm Pharmacol Ther ; 52: 7-17, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30077809

RESUMO

INTRODUCTION: Many patients with chronic obstructive pulmonary disease or asthma experience difficulties in coordinating inhalation with pressurized metered-dose inhaler (pMDI) actuation. The use of a spacer device can improve drug delivery in these patients. The aim of this study was to establish the relative bioavailability of single doses of Symbicort® (budesonide/formoterol) pMDI 160/4.5 µg/actuation (2 actuations) used with and without a spacer device. In addition, an in vitro study was conducted to characterize performance of the inhaler when used in conjunction with a spacer device. METHODS: A Phase I, randomized, open-label, single-dose, single-center, crossover study in 50 healthy volunteers (NCT02934607) assessed the relative bioavailability of single-dose Symbicort® pMDI 160/4.5 µg/actuation (2 actuations) with and without a spacer (AeroChamber Plus® Flow-Vu®). Inhaled doses were administered without or with activated charcoal (taken orally) to estimate total systemic exposure and exposure through the lung, respectively. The in vitro study characterized the effect of the spacer with respect to delivered dose, fine particle dose, and dose during simulated breathing of budesonide and formoterol. RESULTS: In terms of total systemic exposure, use of the spacer increased the relative bioavailability determined by AUC(0-last) and Cmax by 68% (spacer:no spacer treatment ratio, 167.9%; 90% CI, 144.1 to 195.6) and 99% (ratio, 198.7%; 90% CI, 164.4 to 240.2) for budesonide, and 77% (ratio, 176.6%; 90% CI, 145.1 to 215.0) and 124% (ratio, 223.6%; 90% CI, 189.9 to 263.3) for formoterol, respectively, compared with pMDI alone. Similarly, the lung exposure of budesonide and formoterol increased (AUC(0-last) and Cmax by 146% [ratio, 246.0%; 90% CI, 200.7 to 301.6] and 127% [ratio, 226.5%; 90% CI, 186.4 to 275.4] for budesonide, and 173% [ratio, 272.8%; 90% CI, 202.5 to 367.4] and 136% [ratio, 236.2%; 90% CI, 192.6 to 289.6] for formoterol, respectively) when the pMDI was administered through the spacer. When assessed by AUC(0-last) quartile without spacer, subjects in the lowest exposure quartile (indicating poor inhalation technique) with Symbicort® pMDI 160/4.5 µg/actuation (2 actuations) had markedly increased total systemic and lung exposure when the same dose was administered with the spacer. In contrast, for subjects in the highest exposure quartile with pMDI alone, total systemic and lung exposure of formoterol and budesonide was similar with and without the spacer. In the in vitro study, the fine particle dose (<5 µm) of both budesonide and formoterol from the spacer at delay time (i.e. pause period after actuation) = 0 s (instantaneous) after actuation was similar to the fine particle dose when not using the spacer. The delivered doses of budesonide and formoterol from the spacer were both lower compared with the doses administered without the spacer. There was also a decrease in delivered dose with increasing delay time. CONCLUSIONS: The clinical study demonstrated that in subjects with poor inhalation technique the use of the AeroChamber Plus® Flow-Vu® spacer increased the bioavailability of Symbicort® pMDI to a level observed in subjects with good inhalation technique without a spacer. The findings from the in vitro study support the fine particle dose characteristics of Symbicort® pMDI with the AeroChamber Plus® Flow-Vu® spacer.


Assuntos
Combinação Budesonida e Fumarato de Formoterol/administração & dosagem , Combinação Budesonida e Fumarato de Formoterol/farmacocinética , Espaçadores de Inalação , Pulmão/metabolismo , Administração por Inalação , Adulto , Disponibilidade Biológica , Broncodilatadores/administração & dosagem , Budesonida/sangue , Budesonida/farmacocinética , Estudos Cross-Over , Feminino , Fumarato de Formoterol/sangue , Fumarato de Formoterol/farmacocinética , Humanos , Masculino , Inaladores Dosimetrados , Pessoa de Meia-Idade
9.
Lancet Respir Med ; 6(2): 117-126, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29331313

RESUMO

BACKGROUND: The peripheral blood eosinophil count might help identify those patients with chronic obstructive pulmonary disease (COPD) who will experience fewer exacerbations when taking inhaled corticosteroids (ICS). Previous post-hoc analyses have proposed eosinophil cutoffs that are both arbitrary and limited in evaluating complex interactions of treatment response. We modelled eosinophil count as a continuous variable to determine the characteristics that determine both exacerbation risk and clinical response to ICS in patients with COPD. METHODS: We analysed data from three AstraZeneca randomised controlled trials of budesonide-formoterol in patients with COPD with a history of exacerbations and available blood eosinophil counts. Patients with any history of asthma were excluded. Negative binomial regression analysis was done using splines for modelling of continuous variables to study the primary outcome of annual exacerbation rate adjusted for exposure time and study design. The trials are registered with ClinicalTrials.gov, NCT00206167, NCT00206154, and NCT00419744. FINDINGS: 4528 patients were studied. A non-linear increase in exacerbations occurred with increasing eosinophil count in patients who received formoterol alone. At eosinophil counts of 0·10 × 109 cells per L or more, a significant treatment effect was recorded for exacerbation reduction with budesonide-formoterol compared with formoterol alone (rate ratio 0·75, 95% CI 0·57-0·99; pinteraction=0·015). Interactions were observed between eosinophil count and the treatment effects of budesonide-formoterol over formoterol on St George's Respiratory Questionnaire (pinteraction=0·0043) and pre-bronchodilator FEV1 (linear effect p<0·0001, pinteraction=0·067). Only eosinophil count and smoking history were independent predictors of response to budesonide-formoterol in reducing exacerbations (eosinophil count, pinteraction=0·013; smoking history, pinteraction=0·015). INTERPRETATION: In patients with COPD treated with formoterol, blood eosinophil count predicts exacerbation risk and the clinical response to ICS. FUNDING: AstraZeneca.


Assuntos
Broncodilatadores/uso terapêutico , Budesonida/uso terapêutico , Eosinófilos , Doença Pulmonar Obstrutiva Crônica/sangue , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Broncodilatadores/efeitos adversos , Broncodilatadores/sangue , Budesonida/efeitos adversos , Budesonida/sangue , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Risco , Terapêutica
10.
Int J Pharm ; 532(1): 337-344, 2017 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-28890175

RESUMO

The growing interest in the inhalable pharmaceutical products requires advanced approaches to safe and fast product development, such as in silico tools that can be used for estimating the bioavailability and toxicity of developed formulation. GastroPlus™ is one of the few available software packages for in silico simulation of PBPK profile of inhalable products. It contains a complementary module for calculating the lung deposition, the permeability and the systemic absorption of inhalable products. Experimental values of lung deposition and permeability can also be used. This study aims to assess the efficiency of simulation by applying experimental permeability and deposition values, using budesonide as a model substance. The lung deposition values were obtained from the literature, the lung permeability data were experimentally determined by culturing Calu-3 cells under air-liquid interface and submersed conditions to morphologically resemble bronchial and alveolar epithelial cells, respectively. A two-compartment PK model was created for i.v. administration and used as a background for the in silico simulation of the plasma profile of budesonide after inhalation. The predicted plasma profile was compared with the in vivo data from the literature and the effects of experimental lung deposition and permeability on prediction were assessed. The developed model was significantly improved by using realistic lung deposition data combined with experimental data for peripheral permeability.


Assuntos
Broncodilatadores/farmacocinética , Budesonida/farmacocinética , Pulmão/metabolismo , Modelos Biológicos , Administração por Inalação , Administração Intravenosa , Broncodilatadores/administração & dosagem , Broncodilatadores/sangue , Budesonida/administração & dosagem , Budesonida/sangue , Linhagem Celular Tumoral , Simulação por Computador , Humanos , Permeabilidade , Software
11.
Scand J Med Sci Sports ; 27(7): 684-691, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27060857

RESUMO

While chronic systemic administration of glucocorticoids increases muscle Na+ ,K+ ATPase content, such effect is unexplored after therapeutic inhalation. We investigated the effect of therapeutic inhalation of the glucocorticoid budesonide on Na+ ,K+ ATPase content of skeletal muscle in men. Ten healthy trained subjects, aged 23 ± 4 years (mean ± 95% CI), participated in the study. Before and after 2 weeks of daily inhalation of budesonide (1.6 mg/day), a biopsy was taken from the vastus lateralis muscle for measurement of Na+ ,K+ ATPase content and blood samples were drawn for determination of plasma budesonide, cortisol, and K+ . Subjects' performance during cycling to fatigue at 90% of incremental peak power output (iPPO) was measured in response to 4 mg inhaled terbutaline to maximally stimulate Na+ ,K+ ATPase activity. Plasma concentrations of budesonide rose to 5.0 ± 1.6 nM with the intervention, whereas no changes were observed in plasma cortisol. Muscle Na+ ,K+ ATPase content increased (P ≤ 0.01) by 46 ± 34 pmol/(g wet wt) (17% increase) with the intervention. Cycling performance at 90% of iPPO did not change (P = 0.21) with the intervention (203 vs 214 s) in response to terbutaline. The present observations show that therapeutic inhalation of glucocorticoids increases muscle Na+ ,K+ ATPase content, but does not enhance high-intensity cycling endurance in response to terbutaline.


Assuntos
Budesonida/farmacologia , Exercício Físico/fisiologia , Resistência Física/efeitos dos fármacos , Músculo Quadríceps/efeitos dos fármacos , ATPase Trocadora de Sódio-Potássio/metabolismo , Terbutalina/farmacologia , Administração por Inalação , Adulto , Biópsia , Budesonida/administração & dosagem , Budesonida/sangue , Humanos , Hidrocortisona/sangue , Estudos Longitudinais , Masculino , Potássio/sangue , Músculo Quadríceps/enzimologia , Terbutalina/administração & dosagem , Adulto Jovem
12.
Toxicol Appl Pharmacol ; 298: 9-18, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-26952014

RESUMO

Chlorine is a commonly used, reactive compound to which humans can be exposed via accidental or intentional release resulting in acute lung injury. Formulations of rolipram (a phosphodiesterase inhibitor), triptolide (a natural plant product with anti-inflammatory properties), and budesonide (a corticosteroid), either neat or in conjunction with poly(lactic:glycolic acid) (PLGA), were developed for treatment of chlorine-induced acute lung injury by intramuscular injection. Formulations were produced by spray-drying, which generated generally spherical microparticles that were suitable for intramuscular injection. Multiple parameters were varied to produce formulations with a wide range of in vitro release kinetics. Testing of selected formulations in chlorine-exposed mice demonstrated efficacy against key aspects of acute lung injury. The results show the feasibility of developing microencapsulated formulations that could be used to treat chlorine-induced acute lung injury by intramuscular injection, which represents a preferred route of administration in a mass casualty situation.


Assuntos
Lesão Pulmonar Aguda/prevenção & controle , Budesonida/uso terapêutico , Cloro/toxicidade , Diterpenos/uso terapêutico , Descoberta de Drogas/métodos , Exposição por Inalação/efeitos adversos , Fenantrenos/uso terapêutico , Rolipram/uso terapêutico , Lesão Pulmonar Aguda/induzido quimicamente , Animais , Budesonida/administração & dosagem , Budesonida/sangue , Química Farmacêutica , Diterpenos/administração & dosagem , Diterpenos/sangue , Portadores de Fármacos/química , Liberação Controlada de Fármacos , Compostos de Epóxi/administração & dosagem , Compostos de Epóxi/sangue , Compostos de Epóxi/uso terapêutico , Injeções Intramusculares , Masculino , Camundongos Endogâmicos , Microscopia Eletrônica de Varredura , Fenantrenos/administração & dosagem , Fenantrenos/sangue , Rolipram/administração & dosagem , Rolipram/sangue , Propriedades de Superfície
13.
Dig Dis Sci ; 61(6): 1582-90, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26921083

RESUMO

BACKGROUND: Topical steroids prepared as oral viscous slurries have become common in the treatment of eosinophilic esophagitis. Esophageal mucosal contact time correlates with clinical and histologic improvement. AIM: To compare the mucosal contact time of alternative oral viscous budesonide (OVB) slurries with the conventional sucralose OVB. METHODS: A blinded randomized crossover trial investigating esophageal clearance of three OVB slurry preparations was done on healthy adults. Honey and xanthan gum OVB slurries were compared with standard sucralose OVB in 24 randomly assigned subjects. Each subject ingested the sucralose OVB and either the honey or xanthan gum OVB slurries. The esophageal clearance of each slurry was evaluated as an area under the curve (AUC) using 1 millicurie of technetium-99m-sulfur colloid (Tc99) co-administered in each OVB preparation using nuclear scintigraphy. A standardized taste survey was also administered. RESULTS: Xanthan gum had greater mucosal contact time compared to sucralose as measured by a higher AUC at 3 min (P = 0.002), while honey showed no significant difference in esophageal clearance relative to sucralose. Taste scores were significantly higher in the honey group, while scores for xanthan gum were no different from standard sucralose. CONCLUSION: OVB slurries utilizing xanthan gum may be a superior alternative to a sucralose-based slurry due to its increased mucosal contact time and similar taste tolerance. Honey may be a suitable alternative as well, due to its similar contact time and favorable taste.


Assuntos
Budesonida/administração & dosagem , Budesonida/farmacocinética , Administração Oral , Adulto , Área Sob a Curva , Budesonida/sangue , Estudos Cross-Over , Feminino , Mel/análise , Humanos , Masculino , Pessoa de Meia-Idade , Polissacarídeos Bacterianos/química , Sacarose/análogos & derivados , Adulto Jovem
14.
Int J Clin Pharmacol Ther ; 53(7): 593-602, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26042485

RESUMO

OBJECTIVE: Budesonide formoterol (BF) Spiromax® is a breath-actuated dry-powder inhaler designed to deliver similar combinations of budesonide and formoterol as Symbicort® Turbohaler®. We performed two studies to demonstrate pharmacokinetic (PK) equivalence of BF Spiromax with BF Turbohaler. MATERIALS AND METHODS: Two single-center, open-label, randomized, 5-period crossover studies were performed. The first study compared BF Spiromax 160/4.5 µg with BF Turbohaler 200/6 µg, while the second study compared BF Spiromax 320/9 µg with BF Turbohaler 400/12 µg. All treatments were administered with and without charcoal. PK parameters were calculated by measuring plasma drug concentrations from blood samples taken pre-dose and up to 24 hours post-dose. RESULTS: In each study, 90 healthy volunteers were randomized. Bioequivalence of BF Spiromax with BF Turbohaler was demonstrated for budesonide and formoterol (AUC0-t and Cmax (90% confidence intervals of the geometric mean between-device ratios for both parameters were within the predefined range of 0.80-1.25 in both studies)). Equivalence was observed without use of charcoal (overall absorption post-inhalation) and with charcoal (pulmonary absorption). There were no major differences between treatments in tmax for either budesonide or formoterol. All study treatments were well tolerated (one treatment-emergent adverse event (TEAE) in the medium-dose study and four TEAEs in the high-dose study). CONCLUSIONS: These studies indicate that BF Spiromax (±charcoal block) is bioequivalent to BF Turbohaler with respect to the PK parameters assessed. Single doses of BF Spiromax were well tolerated; the overall safety profile of BF Spiromax and BF Turbohaler was similar.


Assuntos
Agonistas de Receptores Adrenérgicos beta 2/administração & dosagem , Agonistas de Receptores Adrenérgicos beta 2/farmacocinética , Broncodilatadores/administração & dosagem , Broncodilatadores/farmacocinética , Budesonida/administração & dosagem , Budesonida/farmacocinética , Carvão Vegetal , Inaladores de Pó Seco , Etanolaminas/administração & dosagem , Etanolaminas/farmacocinética , Glucocorticoides/administração & dosagem , Glucocorticoides/farmacocinética , Administração por Inalação , Agonistas de Receptores Adrenérgicos beta 2/efeitos adversos , Agonistas de Receptores Adrenérgicos beta 2/sangue , Adulto , Broncodilatadores/efeitos adversos , Broncodilatadores/sangue , Budesonida/efeitos adversos , Budesonida/sangue , Estudos Cross-Over , Combinação de Medicamentos , Desenho de Equipamento , Etanolaminas/efeitos adversos , Etanolaminas/sangue , Feminino , Fumarato de Formoterol , Glucocorticoides/efeitos adversos , Glucocorticoides/sangue , Voluntários Saudáveis , Humanos , Masculino , Equivalência Terapêutica , Adulto Jovem
15.
Artigo em Inglês | MEDLINE | ID: mdl-25228411

RESUMO

A semi-automated method for quantification of budesonide in human plasma was developed, validated, and applied for high-volume analysis of samples in connection with a pharmacokinetic study. Protein and phospholipid removal was performed using an Ostro 96-well filter plate and subsequently combined with C18 solid-phase extraction on a Hamilton Microlab STARlet automation robot. The final extracts were evaporated to dryness and redissolved in 20% acetonitrile/water. The procedure used budesonide-d8 as internal standard and gave a 3.5-fold concentration of plasma to extract. The final extracts (5 µL injected) were analyzed with selected reaction monitoring liquid chromatography-tandem mass spectrometry (LC-MS/MS) using electrospray ionization in positive mode. The chromatography system used a 100 mm ACQUITY BEH UPLC column and a gradient system consisting of aqueous 0.1% formic acid and acetonitrile as organic modifier. Phospholipid removal was found to be needed during method development in order to reduce ion suppression effects from matrix and to increase method sensitivity. The measuring range was 50-5000 pg/mL with and LOD 24 pg/mL. Calibration response showed good linearity (correlation coefficients<0.99) over the measuring range. The absolute recovery over the sample preparation procedure was estimated to 67%. Total imprecision was <9% at three levels and accuracy was between 98.9 and 103%. The method was successfully applied for analysis of 864 study samples in a short time. The quality control samples at concentration levels 200 and 2000 pg/mL gave a total imprecision of 7.4% and 4.2%, respectively, (n=95).


Assuntos
Budesonida/sangue , Cromatografia Líquida/métodos , Fosfolipídeos/isolamento & purificação , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Automação , Humanos , Limite de Detecção , Modelos Lineares , Fosfolipídeos/química , Reprodutibilidade dos Testes
16.
J Pharm Pharmacol ; 66(12): 1677-85, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25109416

RESUMO

OBJECTIVES: The aim of this study was to compare lung deposition and assess the bioequivalence of two formulations containing budesonide and formoterol and being delivered via Elpenhaler and Turbuhaler, respectively. A pharmacokinetic (PK) study was conducted. METHODS: An open, randomized, two-sequence, two-period, crossover, single-dose study in 100 asthmatic patients under fasting conditions was performed. Wash out period was 6 days. Equivalence in lung deposition was assessed after a single inhalation of each treatment with concomitant oral administration of activated charcoal (40 g) to prevent gastrointestinal absorption of the drugs. Several PK parameters were estimated, the area under the drug concentration in plasma versus time curve (AUC0-t ) and the maximum drug concentration in plasma (Cmax ) being the primary response variables. Equivalent lung deposition was concluded if the 90% confidence interval (CI) for the Elpenhaler/Turbuhaler geometric mean ratio of AUC0-t and Cmax , for both drug substances fell within the regulatory limits (0.80-1.25). KEY FINDINGS: Acceptance criteria were met. Equivalent lung deposition can be concluded. No statistically significant differences between treatments in the incidence of adverse events were found. CONCLUSIONS: The formulations are bioequivalent regarding both rate and extent of absorption. The treatments were also well tolerated by the participating subjects.


Assuntos
Asma/tratamento farmacológico , Broncodilatadores/farmacocinética , Budesonida/farmacocinética , Etanolaminas/farmacocinética , Administração por Inalação , Adolescente , Adulto , Idoso , Área Sob a Curva , Asma/sangue , Broncodilatadores/administração & dosagem , Broncodilatadores/sangue , Broncodilatadores/uso terapêutico , Budesonida/administração & dosagem , Budesonida/sangue , Budesonida/uso terapêutico , Estudos Cross-Over , Combinação de Medicamentos , Inaladores de Pó Seco , Etanolaminas/administração & dosagem , Etanolaminas/sangue , Etanolaminas/uso terapêutico , Feminino , Fumarato de Formoterol , Humanos , Pulmão/metabolismo , Masculino , Pessoa de Meia-Idade , Equivalência Terapêutica , Distribuição Tecidual , Adulto Jovem
17.
J Pharm Biomed Anal ; 90: 198-206, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24389462

RESUMO

An ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC/MS/MS) method was developed and validated for the quantification of cortisol and budesonide in human plasma. Charcoal stripped human plasma was used as the blank matrix during validation. Cortisol, budesonide, and dexamethasone (internal standard) were extracted from human plasma with methyl-tert-butyl ether, and the chromatographic separation of the peaks was achieved using a Waters Acquity UPLC BEH C18, 1.7 µm, 2.1 mm × 50 mm column with a run time of 4.0 min. Cortisol, budesonide, and dexamethasone were monitored at the total ion current of their respective multiple reaction monitoring transition signals. The UHPLC/MS/MS system consisted of an Agilent 1290 Infinity ultra high performance liquid chromatograph coupled with an AB Sciex Qtrap(®) 5500 hybrid linear ion-trap triple quadrupole mass spectrometer. The method was validated for accuracy, precision, linearity, range, selectivity, lower limit of quantification (LLOQ), recovery, matrix effect, dilution integrity, and evaluation of carry-over. All validation parameters met the acceptance criteria according to regulatory guidelines. The LLOQ was 1.0 ng/mL for both compounds requiring 100 µL of sample. To our knowledge, this is the first validated LC/MS/MS method for the simultaneous quantitative analysis of cortisol and budesonide in human plasma. The method was applied successfully in a clinical investigation of the impact of nasally administered Pulmicort (budesonide) on the hypothalamic-pituitary-adrenal axis of patients with chronic rhinosinusitis.


Assuntos
Budesonida/sangue , Cromatografia Líquida de Alta Pressão/métodos , Hidrocortisona/sangue , Espectrometria de Massas em Tandem/métodos , Budesonida/farmacologia , Glucocorticoides/sangue , Glucocorticoides/farmacologia , Humanos , Sistema Hipotálamo-Hipofisário/efeitos dos fármacos , Sistema Hipotálamo-Hipofisário/metabolismo , Limite de Detecção , Sistema Hipófise-Suprarrenal/efeitos dos fármacos , Sistema Hipófise-Suprarrenal/metabolismo , Reprodutibilidade dos Testes
18.
J Int Med Res ; 41(2): 386-94, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23569029

RESUMO

OBJECTIVE: To compare the pharmacokinetics of the extended-release MMX® formulation of budesonide (Uceris®) with that of Entocort® EC, an extended (controlled ileal) release formulation of budesonide. METHODS: Using an open-label, randomized, three-period crossover, Latin square design, healthy male or female volunteers received single doses of 6 mg Uceris®, 9 mg Uceris® or 9 mg Entocort® EC. Standard pharmacokinetic parameters were assessed. RESULTS: The study included 12 subjects. The 9 mg Uceris® and 9 mg Entocort® EC formulations had comparable area under the concentration-time curve (AUC) data, but 9 mg Uceris® had a notably longer time to first appearance in plasma (median Tlag, 6 h versus 1 h, respectively), and a delayed time to maximum concentration (median Tmax, 15 h versus 5 h, respectively) compared with 9 mg Entocort® EC. The ratio of log-transformed AUC0-last (Uceris®/Entocort® EC) was 91% (90% confidence interval [CI] 77%, 108%) and the corresponding maximum concentration ratio was 79% (90% CI 63%, 100%). CONCLUSION: Uceris was associated with a similar extent (AUC) of systemic exposure to budesonide compared with that following Entocort. However, for Uceris, the pharmacokinetic profile was delayed, a pattern consistent with greater colonic delivery of the active substance.


Assuntos
Budesonida/farmacocinética , Voluntários Saudáveis , Administração Oral , Adolescente , Adulto , Disponibilidade Biológica , Budesonida/administração & dosagem , Budesonida/sangue , Cápsulas , Preparações de Ação Retardada , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Comprimidos , Adulto Jovem
19.
Artigo em Inglês | MEDLINE | ID: mdl-23416292

RESUMO

Budesonide (BUD) is used as a mixture of 22R and 22S epimers for the topical treatment of asthma, rhinitis, and inflammatory bowel disease. To study stereoselectivity in the pharmacokinetics of each epimer, we developed a stereoselective and sensitive ultra-high-performance liquid chromatography-tandem mass spectrometry method for the quantitative determination of 22R and 22S epimers of BUD in human plasma. The epimers of BUD were extracted from plasma using n-hexane/dichloromethane/isopropanol (2:1:0.1, v/v/v) under alkaline conditions. Baseline separation was obtained within 7min on an Acquity UPLC BEH C18 (50mm×2.1mm, 1.7µm) column using an isocratic mobile phase consisting of acetonitrile/5mM ammonium acetate/acetic acid (29:71:0.142, v/v/v) at a flow rate of 0.7mL/min. Mass spectrometric detection was performed in a multiple reaction monitoring mode using the m/z 489→357 transition for BUD epimers and the m/z 497→357 transition for the internal standard d8-BUD epimers. Calibration curves were linear over the concentration ranges of 5.0-500 and 5.0-3000pg/mL for 22R-BUD and 22S-BUD, respectively. The lower limit of quantification was 5.0pg/mL for both epimers. The method was successfully applied in a pharmacokinetic study of BUD controlled-release capsules in humans. Consistent differences in the pharmacokinetics of the 22R and 22S epimers were observed, the AUC(0-∞) of 22S-BUD was approximately six times higher than that of 22R-BUD, and the 22S-/22R-BUD ratio of total body clearance was 0.17.


Assuntos
Anti-Inflamatórios/sangue , Budesonida/sangue , Glucocorticoides/sangue , Espectrometria de Massas em Tandem/métodos , Adulto , Anti-Inflamatórios/química , Budesonida/química , Cromatografia Líquida de Alta Pressão/métodos , Feminino , Glucocorticoides/química , Humanos , Masculino , Sensibilidade e Especificidade , Estereoisomerismo
20.
Am J Vet Res ; 74(1): 78-83, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23270349

RESUMO

OBJECTIVE: To evaluate the pharmacokinetics and clinical efficacy of budesonide in dogs with inflammatory bowel disease (IBD). ANIMALS: 11 dogs (mean ± SD age, 5.7 ± 3.9 years; various breeds and body weights) with moderate or severe IBD. PROCEDURES: Each dog received a controlled-release formulation of budesonide (3 mg/m(2), PO, q 24 h) for 30 days (first day of administration was day 1). The concentration of budesonide and its metabolite (16-α-hydroxyprednisolone) was measured via liquid chromatography-tandem mass spectrometry in plasma and urine samples obtained on days 1 and 8 of treatment. On those days, plasma samples were obtained before the daily budesonide administration and 0.5, 1, 2, 4, and 7 hours after drug administration, whereas urine samples were obtained after collection of the last blood sample. A clinical evaluation was performed on the dogs before onset of drug administration and on days 20 and 30 after start of drug administration. RESULTS: The highest plasma concentration of budesonide and 16-α-hydroxyprednisolone on day 1 was detected at 1 hour and at 2 hours after drug administration, respectively. After standardization on the basis of specific gravity, the ratio between urinary concentrations of budesonide and 16-α-hydroxyprednisolone was 0.006 and 0.012 on days 1 and 8, respectively. The clinical response was adequate in 8 of 11 dogs. CONCLUSIONS AND CLINICAL RELEVANCE: Budesonide was rapidly absorbed and metabolized in dogs with IBD. The drug gradually accumulated, and there was an adequate therapeutic response and no adverse effects.


Assuntos
Budesonida/farmacocinética , Budesonida/uso terapêutico , Doenças do Cão/tratamento farmacológico , Glucocorticoides/farmacocinética , Glucocorticoides/uso terapêutico , Doenças Inflamatórias Intestinais/veterinária , Administração Oral , Animais , Anti-Inflamatórios/sangue , Anti-Inflamatórios/farmacocinética , Anti-Inflamatórios/uso terapêutico , Budesonida/sangue , Cromatografia Líquida/veterinária , Doenças do Cão/metabolismo , Cães , Feminino , Glucocorticoides/sangue , Doenças Inflamatórias Intestinais/tratamento farmacológico , Doenças Inflamatórias Intestinais/metabolismo , Masculino , Prednisolona/análogos & derivados , Prednisolona/sangue , Prednisolona/farmacocinética , Prednisolona/uso terapêutico , Espectrometria de Massas em Tandem/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...