Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.469
Filtrar
2.
J Refract Surg ; 40(6): e354-e361, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848053

RESUMO

PURPOSE: To assess the predictive accuracy of new-generation online intraocular lens (IOL) power formulas in eyes with previous myopic laser refractive surgery (LRS) and to evaluate the influence of corneal asphericity on the predictive accuracy. METHODS: The authors retrospectively evaluated 52 patients (78 eyes) with a history of laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) who subsequently underwent cataract surgery. Refractive prediction errors were calculated for 12 no-history new online formulas: 8 formulas with post-LRS versions (Barrett True-K, EVO 2.0, Hoffer QST, and Pearl DGS) using keratometry and posterior/total keratometry measured by IOLMaster 700 and 4 formulas without post-LRS versions (Cooke K6 and Kane) using keratometry and total keratometry. The refractive prediction error, mean absolute error (MAE), and percentages of eyes with prediction errors of ±0.25, ±0.50, ±0.75, ±1.00, and ±1.50 diopters (D) were compared. RESULTS: The MAEs of the 12 formulas were significantly different (F = 83.66, P < .001). The MAEs ranged from 0.62 to 0.94 D and from 1.07 to 1.84 D in the formulas with and without post-LRS versions, respectively. The EVO formula produced the lowest MAE (0.60) and MedAE (0.47), followed by the Barrett True-K (0.69 and 0.50, respectively). Each percentage of eyes with refractive prediction error was also significantly different among the 12 formulas (P < .001). CONCLUSIONS: The EVO and Barrett True-K formulas demonstrate comparable performance to the other existing formulas in eyes with a history of myopic LASIK/PRK. Surgeons should use these formulas with post-LRS versions and input keratometric values whenever possible. [J Refract Surg. 2024;40(6):e354-e361.].


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Implante de Lente Intraocular , Lentes Intraoculares , Miopia , Óptica e Fotônica , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Feminino , Masculino , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Ceratectomia Fotorrefrativa/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Adulto , Acuidade Visual/fisiologia , Lasers de Excimer/uso terapêutico , Córnea/cirurgia , Córnea/fisiopatologia , Reprodutibilidade dos Testes , Biometria/métodos , Facoemulsificação , Idoso
4.
J Refract Surg ; 40(6): e420-e434, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848055

RESUMO

PURPOSE: To discuss factors influencing corneal aberrations that might influence the optical quality after intraocular lens (IOL) implantation. METHODS: PubMed and Scopus were the main resources used to search the medical literature. An extensive search was performed to identify relevant articles concerning factors influencing the level of corneal aberrations as of August 27, 2023. The following keywords were used in various combinations: corneal, aberrations, defocus, astigmatism, spherical aberration, coma, trefoil, quadrafoil, intraocular lens, and IOL. RESULTS: Conclusive evidence is lacking regarding the correlation between age and changes in corneal aberrations. Patients with astigmatism have greater corneal higher-order aberrations than those with minimal astigmatism, particularly concerning trefoil and coma. Increased levels of corneal higher-order aberrations are noted following contact lens wear, in patients with dry eye disease, and with pterygium. Increased higher-order aberrations have been reported following corneal refractive surgery and for 3 months following trabeculectomy; regarding intraocular lens surgery, the results remain controversial. CONCLUSIONS: Several factors influence the level of corneal higher-order aberrations. Multifocal and extended depth-of-focus IOLs can share similarities in their optical properties, and the main difference arises in their design and performance with respect to spherical aberration. Preoperative evaluation is critical for proper IOL choice, particularly in corneas with risk of high levels of aberrations. [J Refract Surg. 2024;40(6):e420-e434.].


Assuntos
Aberrações de Frente de Onda da Córnea , Implante de Lente Intraocular , Refração Ocular , Acuidade Visual , Humanos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Fatores de Risco , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Lentes Intraoculares Multifocais , Percepção de Profundidade/fisiologia , Topografia da Córnea , Córnea/fisiopatologia
5.
Invest Ophthalmol Vis Sci ; 65(6): 15, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38848076

RESUMO

Purpose: The purpose of this study was to investigate the associations between visual function and severity grading, corneal scatter, or higher-order aberrations (HOAs) in patients with Fuchs endothelial corneal dystrophy (FECD). Methods: This observational case series study included 49 eyes of 27 patients with FECD and 10 eyes of 10 healthy individuals. We evaluated corrected distance visual acuity (CDVA) using Landolt-C and Early Treatment Diabetic Retinopathy Study charts and contrast sensitivity using the CSV-1000E chart and CSV-1000RN letter chart. We analyzed the associations between visual function and explanatory variables, including age, modified Krachmer grade, central corneal thickness (CCT), anterior segment optical coherence tomography (AS-OCT)-based grade, HOAs, intraocular straylight, and corneal densitometry. We additionally conducted receiver operating characteristic (ROC) analysis to identify the corneal densitometry thresholds for decreased visual function. Results: There were significant associations between visual function and the modified Krachmer grade, CCT, AS-OCT-based grade, HOAs, intraocular straylight, and corneal densitometry. A modified Krachmer grade ≥ 3 was identified as a threshold for decreased visual function. Multivariate analysis showed that corneal densitometry was significantly associated with all visual function parameters, and HOAs were significantly associated with CDVA but not with contrast sensitivity. ROC analysis revealed that corneal densitometry of the posterior layer at 0 to 2 mm ≥ 10 grayscale units (GSU), was identified as a threshold for decreased visual function. Conclusions: HOAs, forward and backward light scatter affected visual function, with backward light scatter being the most influential. In patients with FECD, modified Krachmer grade ≥ 3 and corneal densitometry ≥ 10 GSU were thresholds for visual disturbance.


Assuntos
Sensibilidades de Contraste , Aberrações de Frente de Onda da Córnea , Distrofia Endotelial de Fuchs , Espalhamento de Radiação , Acuidade Visual , Humanos , Distrofia Endotelial de Fuchs/fisiopatologia , Distrofia Endotelial de Fuchs/diagnóstico , Feminino , Masculino , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Idoso , Sensibilidades de Contraste/fisiologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Tomografia de Coerência Óptica/métodos , Córnea/fisiopatologia , Córnea/diagnóstico por imagem , Índice de Gravidade de Doença , Curva ROC , Idoso de 80 Anos ou mais , Adulto
6.
Vestn Oftalmol ; 140(2. Vyp. 2): 51-59, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739131

RESUMO

PURPOSE: The study investigates the influence of changes in keratometric parameters after refractive surgery on the results of Maklakov tonometry. MATERIAL AND METHODS: The study examined a total of 61 people (121 eyes). The patients were divided into a control group with no history of surgery (16 people, 31 eyes), a LASIK group (13 people, 26 eyes), a femtosecond-assisted LASIK (FS-LASIK) group (16 people, 32 eyes), and a photorefractive keratectomy (PRK) group (16 people, 32 eyes). The patients underwent standard examination, keratometry (Km), Maklakov tonometry with a 10 g weight, and elastotonometry with 5, 7.5, and 15 g weights. RESULTS: In the LASIK group, the indentation diameter with 5 and 7.5 g weights correlated with Km in the central and near-paracentral zone (r=0.3-0.5). Tonometry with a 10 g weight did not correlate with anything. Tonometry with a 15 g weight inversely correlated with Km in the paracentral points (4 mm) of the strong meridian (r= -0.5 ... -0.7). In the FS-LASIK group, a significant inverse correlation with Km was observed only for the indentation diameter with a 10 g weight in the paracentral (3-4 mm) zone (r= -0.4 ... -0.5). In the PRK group, weak (r<0.4) correlations were found between Km and the indentation diameter of the 7.5 and 10 g weights for the central zone (1-2 mm). No significant correlations were found for 5 and 15 g weights.In the control group, there were practically no correlations for 5 and 7.5 g weights. The indentation diameter of the 10 g weight evenly correlated with Km at all points (r= -0.38 ... -0.60), the indentation of the 15 g weight correlated mainly with the curvature of the horizontal meridian (r= -0.37 ... -0.49). CONCLUSION: Tonometry readings with the 10 g weight are the most dependent on Km in different groups, and the readings with the 5 g weight are the least dependent. LASIK is characterized by the largest scatter of dependencies for weights of different masses, FS-LASIK - by the smallest. Tonometry readings with the 5 g weight correlated with Km only in the LASIK group, and this was the only direct correlation. Considering the inverse nature of most correlations, higher Km may be associated with an overestimation of tonometry results, and lower Km - with its underestimation.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Ceratectomia Fotorrefrativa , Tonometria Ocular , Humanos , Adulto , Masculino , Feminino , Tonometria Ocular/métodos , Ceratectomia Fotorrefrativa/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Córnea/cirurgia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia , Miopia/cirurgia , Miopia/fisiopatologia , Miopia/diagnóstico , Pressão Intraocular/fisiologia
7.
J Biomech ; 169: 112145, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38761745

RESUMO

To investigate the optimal cutting depth (Cap) in small incision lenticule extraction from the perspective of corneal biomechanics, a three-dimensional finite element model of the cornea was established using a stromal sub-regional material model to simulate small incision lenticule extraction. The displacement difference PΔ at the central point of the posterior corneal surface before and after lenticule extraction, as well as the von Mises stress at four points of different thicknesses in the center of the cornea, were analyzed using the finite element model considering the hyperelastic property and the difference in stiffness between the anterior and posterior of the cornea. The numerical curves of PΔ-Cap and von Mises Stress-Cap relations at different diopters show that the displacement difference PΔ has a smallest value at the same diopter. In this case, the von Mises stress at four points with different thicknesses in the center of the cornea was also minimal. Which means that the optimal cutting depth exsisting in the cornea. Moreover, PΔ-Cap curves for different depth of stromal stiffness boundaries show that the optimal cap thickness would change with the depth of the stromal stiffness boundary. These results are of guiding significance for accurately formulating small incision lenticule extraction surgery plans and contribute to the advancement of research on the biomechanical properties of the cornea.


Assuntos
Córnea , Análise de Elementos Finitos , Modelos Biológicos , Humanos , Córnea/cirurgia , Córnea/fisiologia , Córnea/fisiopatologia , Fenômenos Biomecânicos , Substância Própria/cirurgia , Estresse Mecânico , Cirurgia da Córnea a Laser/métodos , Simulação por Computador
8.
J Refract Surg ; 40(5): e336-e343, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717081

RESUMO

PURPOSE: To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS: Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS: The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS: The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].


Assuntos
Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Cirurgia Assistida por Computador , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Acuidade Visual/fisiologia , Estudos Prospectivos , Refração Ocular/fisiologia , Adulto , Masculino , Feminino , Lasers de Excimer/uso terapêutico , Método Duplo-Cego , Miopia/cirurgia , Miopia/fisiopatologia , Adulto Jovem , Cirurgia Assistida por Computador/métodos , Pessoa de Meia-Idade , Córnea/cirurgia , Córnea/fisiopatologia , Seguimentos
9.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717083

RESUMO

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Assuntos
Aberrometria , Astigmatismo , Córnea , Substância Própria , Aberrações de Frente de Onda da Córnea , Densitometria , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Estudos Prospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Adulto , Feminino , Masculino , Lasers de Excimer/uso terapêutico , Acuidade Visual/fisiologia , Substância Própria/cirurgia , Córnea/cirurgia , Córnea/fisiopatologia , Adulto Jovem , Refração Ocular/fisiologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
10.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717086

RESUMO

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Assuntos
Córnea , Elasticidade , Pressão Intraocular , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Humanos , Córnea/fisiopatologia , Córnea/cirurgia , Adulto , Feminino , Masculino , Fenômenos Biomecânicos , Lasers de Excimer/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Adulto Jovem , Elasticidade/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Pressão Intraocular/fisiologia , Ceratectomia Fotorrefrativa/métodos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Estudos Prospectivos , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
11.
Cont Lens Anterior Eye ; 47(3): 102164, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38594154

RESUMO

PURPOSE: To determine the changes in keratometry measurements and refraction in patients having the thermo-mechanical periorbital skin treatment, Tixel®, to treat dry eye disease (DED). METHODS: A multi-centre, prospective, non-masked study was conducted. DED patients were recruited in 3 international centres and were evaluated in 5 visits separated by an interval of 2 weeks except for the last visit which took place after 18 weeks from visit 1. The same clinical examination was performed at all visits: OSDI questionnaire, tear stability, keratometry, best corrected visual acuity and refraction. Tixel® treatment was applied at the first 3 visits. RESULTS: 89 participants (24 males/65 females; mean age: 55.0 ± 14.2 years) were included: 20 presented moderate DED symptoms and 69 severe DED symptoms. Significant differences were found for the spherocylindrical refraction (vector analysis) between visit 1 and visits 2 and 3. Following cumulative analysis, 11.86 % and 16.94 % of participants had more than 0.5 dioptre (D) change in mean keratometry and keratometric astigmatism, respectively, at 3 months post-treatment. A total of 5.40 % had a sphere and cylinder change greater than 0.50D and 16.21 % had the axis changed more than 10 degrees (vector analysis). These changes were particularly significant in patients with severe DED symptoms. CONCLUSIONS: Keratometry readings and refraction can change following thermo-mechanical skin treatment for DED, especially in those patients with severe DED symptoms. This should be considered as potential errors in intraocular lens calculations may be induced.


Assuntos
Extração de Catarata , Síndromes do Olho Seco , Refração Ocular , Acuidade Visual , Humanos , Síndromes do Olho Seco/fisiopatologia , Síndromes do Olho Seco/terapia , Síndromes do Olho Seco/diagnóstico , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Prospectivos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Idoso , Adulto , Córnea/fisiopatologia
12.
Ophthalmic Physiol Opt ; 44(5): 977-986, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38563586

RESUMO

INTRODUCTION: Research assuming linearity has concluded that corneal biomechanics are compromised in high myopia. We investigated whether this assumption was appropriate and re-examined these associations across different levels of myopia. METHODS: Myopic (spherical equivalent refraction, SER ≤ -0.50 D) eyes of 10,488 adults aged 40-69 years without any history of systemic and ocular conditions were identified in the UK Biobank. Ordinary least squares (OLS) regression was employed to test the linear association between corneal hysteresis (CH) or corneal resistance factor (CRF), separately, and SER while controlling for age, sex, corneal radius and intraocular pressure. Quantile regression (QR) was used to test the same set of associations across 49 equally spaced conditional quantiles of SER. RESULTS: In OLS regression, each standard deviation (SD) decrease in CH and CRF was associated with 0.08 D (95% CI: 0.04-0.12; p < 0.001) and 0.10 D (95% CI: 0.04-0.15; p < 0.001) higher myopia, respectively. However, residual analysis indicated that the linearity assumption was violated. QR revealed no evidence of a significant association between CH/CRF and SER in low myopia, but a significant (p < 0.05) positive association became evident from -2.78 D (0.06 and 0.08 D higher myopia per SD decrease in CH and CRF). The magnitude of association increased exponentially with increasing myopia: in the -5.03 D quantile, every SD decrease in CH and CRF was associated with 0.17 D (95% CI: 0.08-0.25; p < 0.001) and 0.21 D (95% CI: 0.10-0.31; p < 0.001) higher myopia. In the -8.63 D quantile, this further increased to 0.54 D (95% CI: 0.33-0.76; p < 0.001) and 0.67 D (95% CI: 0.41-0.93; p < 0.001) higher myopia per SD decrease in CH and CRF. CONCLUSIONS: Corneal biomechanics appeared compromised from around -3.00 D. These changes were observed to be exponential with increasing myopia.


Assuntos
Córnea , Pressão Intraocular , Refração Ocular , Humanos , Pessoa de Meia-Idade , Córnea/fisiopatologia , Feminino , Masculino , Adulto , Idoso , Fenômenos Biomecânicos , Refração Ocular/fisiologia , Pressão Intraocular/fisiologia , Miopia/fisiopatologia , Miopia/epidemiologia , Elasticidade , Miopia Degenerativa/fisiopatologia
13.
Eye Contact Lens ; 50(6): 255-258, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38652487

RESUMO

OBJECTIVE: To evaluate the effects of rigid corneal lenses (RCL) in patients with keratoconus, based on eccentricity. METHODS: Eighty-four eyes from 84 patients were included in this retrospective comparative study. Based on the median value of eccentricity difference between the cornea and back surface of the RCL, the patients were divided into groups 1 (<0.08) and 2 (≥0.08). Visual acuity, refractive index, and corneal topography indices were compared before and three months after lens use. RESULTS: Visual acuity, astigmatism, refractive error, corneal curvature, and corneal thickness improved significantly in both groups. Apical power and anterior elevation improved significantly in group 1, with small differences in eccentricity, but not in group 2. Changes in apical power before and after lens use were significantly different between the two groups. CONCLUSION: The RCL was effective for the cornea of keratoconus, especially when the prescription was made with a small difference in eccentricity.


Assuntos
Lentes de Contato , Córnea , Topografia da Córnea , Ceratocone , Refração Ocular , Acuidade Visual , Humanos , Ceratocone/fisiopatologia , Ceratocone/terapia , Estudos Retrospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Adulto , Refração Ocular/fisiologia , Adulto Jovem , Córnea/patologia , Córnea/fisiopatologia , Adolescente , Astigmatismo/fisiopatologia , Astigmatismo/terapia , Pessoa de Meia-Idade
14.
Indian J Ophthalmol ; 72(5): 712-717, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38648433

RESUMO

PURPOSE: To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively. METHODS: This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups. RESULTS: In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1. CONCLUSION: Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.


Assuntos
Colágeno , Córnea , Topografia da Córnea , Reagentes de Ligações Cruzadas , Ceratocone , Fármacos Fotossensibilizantes , Riboflavina , Raios Ultravioleta , Acuidade Visual , Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Fenômenos Biomecânicos , Colágeno/metabolismo , Córnea/diagnóstico por imagem , Córnea/fisiopatologia , Córnea/efeitos dos fármacos , Substância Própria/metabolismo , Substância Própria/efeitos dos fármacos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Reagentes de Ligações Cruzadas/uso terapêutico , Seguimentos , Ceratocone/tratamento farmacológico , Ceratocone/fisiopatologia , Ceratocone/diagnóstico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Refração Ocular/fisiologia , Riboflavina/uso terapêutico , Acuidade Visual/fisiologia , Criança
15.
Cont Lens Anterior Eye ; 47(3): 102136, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38503665

RESUMO

PURPOSE: To investigate the effects of modifications in back optical zone diameter (BOZD), reverse curve width (RCW), and compression factor (CF) on refractive error changes and axial elongation in myopic children undergoing orthokeratology (ortho-k) over a 12-month period. METHOD: In this retrospective study, data from 126 myopic children undergoing ortho-k fitting were analyzed. Subjects were categorized into four distinct groups based on lens design parameters: Group A (BOZD 6.0 mm, RCW 0.6 mm, CF 0.75 D); Group B (BOZD 6.0 mm, RCW 0.6 mm, CF 1.25 D); Group C (BOZD 5.4 mm, RCW 0.9 mm, CF 1.25 D); and Group D (BOZD 5.0 mm, RCW 1.1 mm, CF 1.25 D). The study evaluated uncorrected visual acuity (UCVA), corneal topography, and axial length (AL) at intervals, using Linear Mixed Models (LMMs) for time-based changes, and ANOVA or Kruskal-Wallis tests for group differences in AL elongation. A multivariable regression analysis identified factors independently associated with AL elongation. RESULTS: Within the first day and week, all four groups displayed significant improvements in UCVA and alterations in corneal curvature, which subsequently stabilized. Although UCVA variations between groups were subtle, Group D had less corneal curvature change than Groups A and B initially and exhibited significantly less AL elongation after one year. No significant difference in corneal curvature change or AL elongation was observed between Group C and the other groups. Multiple regression analysis indicated that older baseline age, greater baseline spherical equivalent refractive error, and smaller BOZD were associated with less AL elongation. CONCLUSION: The study reveals a positive correlation between BOZD and axial length growth over the 12-month period. A pure 0.5 D CF increment demonstrates a nonsignificant impact. This study provides new ideas into optimizing the parameters of ortho-k lenses.


Assuntos
Comprimento Axial do Olho , Lentes de Contato , Topografia da Córnea , Miopia , Procedimentos Ortoceratológicos , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Miopia/fisiopatologia , Miopia/terapia , Feminino , Masculino , Criança , Acuidade Visual/fisiologia , Comprimento Axial do Olho/fisiopatologia , Refração Ocular/fisiologia , Adolescente , Ajuste de Prótese , Córnea/fisiopatologia
16.
Semin Ophthalmol ; 39(5): 376-380, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38466208

RESUMO

PURPOSE: To investigate and compare the association of corneal hysteresis (CH) in patients with secondary glaucoma to control patients and patients with primary open-angle glaucoma (POAG). Additionally, to determine the consistency of CH measurements in patients with secondary glaucoma. METHODS: A total of 84 patients (121 eyes) were prospectively included in this study. Twenty-three patients (46 eyes) were healthy controls, 24 patients (40 eyes) were diagnosed with POAG, and 27 patients (35 eyes) were diagnosed with a form of secondary glaucoma. CH and intraocular pressure (IOP) were measured using the Ocular Response Analyzer. Three measurements per eye were performed and used for the analysis and to determine fluctuations in CH data. One-way ANOVA with post-hoc Bonferroni analysis and Chi-Squared testing was done to determine differences between groups. RESULTS: All patients were matched for age. Patients in both POAG and secondary glaucoma groups were matched for age and IOP. All groups had similar sex and racial compositions as well as similar proportions of diabetes, hypertension, and hyperlipidemia. CH was lower (p < .05) in patients with POAG (9.32 ± 1.64) and secondary glaucoma (7.89 ± 3.18) when compared to healthy controls (11.16 ± 1.60). Fluctuations in CH measurements were minimal in all groups. Further analysis of the secondary glaucoma group revealed no differences in CH between different types of secondary glaucoma (p > .05). CONCLUSION: Patients with secondary glaucoma have lower CH when compared to POAG or control groups. The ORA exhibits precision of CH measurements for control, POAG, and secondary glaucoma groups, making it a reliable tool in management of secondary forms of glaucoma.


Assuntos
Córnea , Glaucoma de Ângulo Aberto , Pressão Intraocular , Tonometria Ocular , Humanos , Feminino , Pressão Intraocular/fisiologia , Masculino , Córnea/fisiopatologia , Estudos Prospectivos , Pessoa de Meia-Idade , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/diagnóstico , Idoso , Elasticidade/fisiologia , Adulto
17.
J Glaucoma ; 33(6): 417-421, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38506830

RESUMO

PRCIS: Elevated corneal hysteresis (CH) and resistance factor (CRF) in obese and overweight children imply weight's effect on corneal biomechanics. Increased Goldmann-correlated intraocular pressure (IOPg) in obese children indicates glaucoma risk, emphasizing screening for IOP and retinal changes. PURPOSE: To evaluate the effect of obesity on corneal biomechanics, retinal nerve fiber layer (RNFL), and central macular thickness (CMT) in children. PATIENTS AND METHODS: In this prospective, cross-sectional, comparative study, 146 eyes of normal-weight, over-weight, and obese children aged between 6 to 17 years were evaluated. The IOPg, corneal compensated IOP (IOPcc), CH, CRF, and the average retinal nerve fiber layer (RNFL), average cup-to-disk ratio (c/d), and central macular thickness (CMT) were measured by Ocular Response Analyser and Spectral-Domain Optical Coherence Tomography (SD-OCT), respectively. RESULTS: There was no statistically significant difference regarding age, gender, IOPcc, average RNFL thickness, c/d ratio, and CMT among the groups ( P ≥0.05). The IOPg was significantly higher in obese children compared with normal-weight children, while CH and CRF values were significantly higher in both obese and over-weight children compared with healthy ones ( P <0.05). There was a positive correlation between BMI percentile and IOPg, CH, and CRF values. CONCLUSION: In our study, higher IOPg, corneal hysteresis, and corneal resistance factor values suggest that obese children could be potential candidates for glaucoma. Therefore, it would be appropriate to screen them for IOP and retinal alterations. Further investigations with larger sample size and longer follow-up are needed to understand the risk of glaucoma in obese children.


Assuntos
Córnea , Pressão Intraocular , Macula Lutea , Fibras Nervosas , Obesidade Infantil , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Tonometria Ocular , Humanos , Criança , Pressão Intraocular/fisiologia , Estudos Transversais , Feminino , Córnea/fisiopatologia , Córnea/diagnóstico por imagem , Córnea/patologia , Masculino , Estudos Prospectivos , Adolescente , Obesidade Infantil/fisiopatologia , Obesidade Infantil/complicações , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Macula Lutea/fisiopatologia , Fenômenos Biomecânicos , Índice de Massa Corporal , Glaucoma/fisiopatologia
18.
Ophthalmic Physiol Opt ; 44(4): 746-756, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38389207

RESUMO

PURPOSE: The goal was to use SyntEyes modelling to estimate the allowable alignment error of wavefront-guided rigid contact lens corrections for a range of normal and keratoconic eye aberration structures to keep objectively measured visual image quality at or above average levels of well-corrected normal eyes. Secondary purposes included determining the required radial order of correction, whether increased radial order of the corrections further constrained the allowable alignment error and how alignment constraints vary with keratoconus severity. METHODS: Building on previous work, 20 normal SyntEyes and 20 keratoconic SyntEyes were fitted with optimised wavefront-guided rigid contact lens corrections targeting between three and eight radial orders that drove visual image quality, as measured objectively by the visual Strehl ratio, to near 1 (best possible) over a 5-mm pupil for the aligned position. The resulting wavefront-guided contact lens was then allowed to translate up to ±1 mm in the x- and y-directions and rotate up ±15°. RESULTS: Allowable alignment error changed as a function of the magnitude of aberration structure to be corrected, which depends on keratoconus severity. This alignment error varied only slightly with the radial order of correction above the fourth radial order. To return the keratoconic SyntEyes to average levels of visual image quality depended on maximum anterior corneal curvature (Kmax). Acceptable tolerances for misalignment that returned keratoconic visual image quality to average normal levels varied between 0.29 and 0.63 mm for translation and approximately ±6.5° for rotation, depending on the magnitude of the aberration structure being corrected. CONCLUSIONS: Allowable alignment errors vary as a function of the aberration structure being corrected, the desired goal for visual image quality and as a function of keratoconus severity.


Assuntos
Lentes de Contato , Topografia da Córnea , Ceratocone , Acuidade Visual , Humanos , Ceratocone/fisiopatologia , Ceratocone/diagnóstico , Topografia da Córnea/métodos , Adulto , Feminino , Masculino , Acuidade Visual/fisiologia , Adulto Jovem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Refração Ocular/fisiologia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia
19.
J Cataract Refract Surg ; 50(6): 550-557, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38305328

RESUMO

PURPOSE: To compare corrected distance visual acuity (CDVA) outcomes of hyperopic laser in situ keratomileusis (LASIK) with a postoperative corneal steepness above vs below 49 diopters (D). SETTING: Care-Vision Laser Centers, Tel-Aviv, Israel. DESIGN: Retrospective study. METHODS: This study included consecutive patients who underwent hyperopic LASIK between January 2013 and December 2019. Hyperopic patients were divided into 2 groups based on postoperative corneal steepness with steep corneas defined >49.0 D and the control group ≤49.0 D. Adjustments were performed to account for differences in baseline and intraoperative parameters. RESULTS: Overall, 1703 eyes of 1703 patients were included. Mean age was 48.3 ± 10.0 years, and 45.3% were male. Preoperatively, the steep group (2.4%, n = 41/1703) had steeper mean (44.6 D vs 43.1 D, P < .001) and steep (45.1 D vs 43.5 D, P < .001) keratometry, worse logMAR CDVA (0.07 vs 0.04, P = .02), and higher sphere (4.9 D vs 2.9 D, P < .001). Intraoperatively, they had a higher spherical treatment (4.6 D vs 2.8 D, P < .001). After hyperopic LASIK, the steep group had worse logMAR CDVA (0.10 vs 0.06, P = .01). However, after accounting for differences in baseline and spherical treatment, no significant differences were found in postoperative logMAR CDVA (0.06 vs 0.06, P = .99). The factors that remained associated with worse postoperative CDVA were higher spherical treatment (0.01 logMAR per 1 D, P < .001) and preoperative CDVA (0.60 logMAR per 1.00 logMAR, P < .001). CONCLUSIONS: Postoperative corneal steepness greater than 49 D is not associated with worse visual outcomes after hyperopic LASIK. However, lower preoperative visual potential and higher spherical treatment applied are associated with worse outcomes. The 49 D cutoff should be revisited.


Assuntos
Córnea , Hiperopia , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Hiperopia/cirurgia , Hiperopia/fisiopatologia , Acuidade Visual/fisiologia , Estudos Retrospectivos , Pessoa de Meia-Idade , Masculino , Feminino , Córnea/fisiopatologia , Lasers de Excimer/uso terapêutico , Refração Ocular/fisiologia , Adulto , Período Pós-Operatório , Topografia da Córnea
20.
Eye (Lond) ; 38(9): 1654-1659, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38402288

RESUMO

BACKGROUND/OBJECTIVES: To determine the relationship between corneal stress-strain index (SSI) and retinal nerve fibre layer (RNFL) thickness. SUBJECTS/METHODS: 1645 healthy university students from a university-based study contributed to the analysis. The RNFL thickness was measured by high-definition optical coherence tomography (HD-OCT), axial length (AL) was measured by IOL Master, and corneal biomechanics including SSI, biomechanical corrected intraocular pressure (bIOP), and central corneal thickness (CCT) were measured by Corvis ST. Multivariate linear regression was performed to evaluate the relationship between the SSI and RNFL thickness after adjusting for potential covariates. RESULTS: The mean age of the participants was 19.0 ± 0.9 years, and 1132 (68.8%) were women. Lower SSI was significantly associated with thinner RNFL thickness ( ß =8.601, 95% confidence interval [CI] 2.999-14.203, P = 0.003) after adjusting for age, CCT, bIOP, and AL. No significant association between SSI and RNFL was found in men, while the association was significant in women in the fully adjusted model. The association was significant in the nonhigh myopic group ( P for trend = 0.021) but not in the highly myopic group. Eyes with greater bIOP and lower SSI had significantly thinner RNFL thickness. CONCLUSIONS: Eyes with lower SSI had thinner RNFL thickness after adjusting for potential covariates, especially those with higher bIOP. Our findings add novel evidence of the relationship between corneal biomechanics and retinal ganglion cell damage.


Assuntos
Córnea , Pressão Intraocular , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Humanos , Feminino , Masculino , Córnea/fisiopatologia , Córnea/patologia , Córnea/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Fibras Nervosas/patologia , Fibras Nervosas/fisiologia , Adulto Jovem , Células Ganglionares da Retina/patologia , Células Ganglionares da Retina/fisiologia , Pressão Intraocular/fisiologia , Voluntários Saudáveis , Estudos Transversais , Fenômenos Biomecânicos , Comprimento Axial do Olho/patologia , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...