J Perinat Med ; 49(5): 566-571, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-33567181

RESUMO

OBJECTIVES: The impedance cardiography (ICG) technique measures the variation of impedance in the thorax due to the physical contractile activity of the heart. Twin pregnancy is characterized by greater maternal hemodynamic changes than a singleton pregnancy. METHODS: In a study on 121 pregnant women in the last trimester we performed ICG, evaluating the following hemodynamic parameters: stroke volume, heart rate, cardiac output, ventricular ejection time, left ventricular ejection time, thoracic impedance, and systemic vascular resistance. RESULTS: The study included singleton and twin pregnancies. Heart rate values in women with single fetus was lower than in those carrying twins (85 vs. 100 beats/min, p=0.021) as were the stroke volume values (64 vs. 83 mL, p=0.010) and the cardiac output (p<0.0001). Systemic vascular resistance decreased in twin pregnancies compared to singleton pregnancy (p=0.023). CONCLUSIONS: ICG studies are rare, and the validation of their results is an ongoing process. However, the ICG technique is applicable in the third trimester of pregnancy and can yield important information regarding the hemodynamic profile of singleton and twin pregnancies, revealing maternal heart changes specific to twin pregnancies.


Assuntos
Cardiografia de Impedância , Hemodinâmica/fisiologia , Terceiro Trimestre da Gravidez/fisiologia , Gravidez de Gêmeos/fisiologia , Gravidez/fisiologia , Adulto , Cardiografia de Impedância/métodos , Cardiografia de Impedância/estatística & dados numéricos , Correlação de Dados , Feminino , Frequência Cardíaca , Humanos , Reprodutibilidade dos Testes , Volume Sistólico , Resistência Vascular
2.
J Clin Monit Comput ; 34(2): 271-276, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31004273

RESUMO

Major hemodynamic changes are frequently noted during liver transplantation (LT). We evaluated the performance of electrical velocimetry (EV) as compared to that of TEE in SV optimization during liver transplantation. This was an observational study in 32 patients undergoing LT. We compared SV values measured simultaneously by EV (SVEV) and TEE (SVTEE) at baseline 30 min after induction, at the end of dissection phase, 30 min after anhepatic phase, 30 min after reperfusion. We also evaluated the reliability of EV to track changes In SV before and after 49 fluid challenges. Finally, the SV variation (SVV) and pulse pressure variation (PPV) were tested as predictors for volume responsiveness, defined as an increase in SV ≥ 10% after 250 ml of colloid. For 112 paired SV data, the overall correlation was 0.76 and bias (limits of agreement) 0.3 (- 29 to 29) ml percentage error 62%. The EV was able to track changes in SV with a concordance rate of 97%, and a sensitivity and specificity of 93% to detect a positive fluid challenge. The AUC values (with 95% confidence intervals) for SVV and PPV were 0.68 (0.52-0.83) and 0.72 (0.57-0.86), respectively, indicating low predictive capacity in these setting. The absolute values of SV derived from EV did not agree with SV derived from TEE. However, EV was able to track the direction of changes in SV during hemodynamic management of patients undergoing liver transplantation.Clinical trial registration: Clinicaltrials.gov Identifier: NCT03228329 prospectively Registered on 13-July-2017.


Assuntos
Monitorização Hemodinâmica/métodos , Transplante de Fígado , Monitorização Intraoperatória/métodos , Ressuscitação , Reologia/métodos , Adulto , Cardiografia de Impedância/métodos , Cardiografia de Impedância/estatística & dados numéricos , Ecocardiografia Transesofagiana , Feminino , Hidratação , Monitorização Hemodinâmica/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/estatística & dados numéricos , Estudos Prospectivos , Reologia/estatística & dados numéricos , Volume Sistólico
3.
Ann Noninvasive Electrocardiol ; 25(3): e12714, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31674726

RESUMO

PURPOSE: The aim is to measure and analyze the wave amplitudes and time intervals of differential graphs of reconstructed impedance cardiography (RICG). METHODS: 180 adults with normal cardiac function between the ages of 18-78 were included in the study. Six mingled impedance changes on chest surface were simultaneously detected for each subject. The differential graphs of five impedance change components of RICG were obtained through waveform separation and software differentiation. The amplitudes of C, X, O, b waves and time intervals of Q-b and Q-C were measured and statistically analyzed. RESULTS: The amplitudes of C and X waves in PL, PR, AO, and that of C, O, b waves in LV and RV, all decrease as age increases. Wave amplitudes of the female group were bigger than those of the male group (p < .01), while the Q-C intervals of the female group were shorter than that of the male group (p < .01). Among five impedance change components, the wave amplitude of AO was larger than those of PL and PR (p < .01), and wave amplitudes of PL and PR were bigger than those of LV and RV (p < .01). Q-C intervals of LV and RV were longer than those of AO, PL and PR (p < .01), while the Q-b intervals of LV and RV were shorter than the Q-C intervals of AO, PL, and PR. CONCLUSIONS: The differential graphs of RICG could reflect indirectly the physiological activities and pathological changes of the heart and of the large blood vessels in thorax.


Assuntos
Cardiografia de Impedância/métodos , Cardiografia de Impedância/estatística & dados numéricos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
4.
J Clin Monit Comput ; 29(6): 789-800, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25682204

RESUMO

The goal of this study is to validate a new, continuous, noninvasive stroke volume (SV) method, known as transbrachial electrical bioimpedance velocimetry (TBEV). TBEV SV was compared to SV obtained by cardiac magnetic resonance imaging (cMRI) in normal humans devoid of clinically apparent heart disease. Thirty-two (32) volunteers were enrolled in the study. Each subject was evaluated by echocardiography to assure that no aortic or mitral valve disease was present. Subsequently, each subject underwent electrical interrogation of the brachial artery by means of a high frequency, low amplitude alternating current. A first TBEV SV estimate was obtained. Immediately after the initial TBEV study, subjects underwent cMRI, using steady-state precession imaging to obtain a volumetric estimate of SV. Following cMRI, the TBEV SV study was repeated. Comparing the cMRI-derived SV to that of TBEV, the two TBEV estimates were averaged and compared to the cMRI standard. CO was computed as the product of SV and heart rate. Statistical methods consisted of Bland-Altman and linear regression analysis. TBEV SV and CO estimates were obtained in 30 of the 32 subjects enrolled. Bland-Altman analysis of pre- and post-cMRI TBEV SV showed a mean bias of 2.87 % (2.05 mL), precision of 13.59% (11.99 mL) and 95% limits of agreement (LOA) of +29.51% (25.55 mL) and -23.77% (-21.45 mL). Regression analysis for pre- and post-cMRI TBEV SV values yielded y = 0.76x + 25.1 and r(2) = 0.71 (r = 0.84). Bland-Altman analysis comparing cMRI SV with averaged TBEV SV showed a mean bias of -1.56% (-1.53 mL), precision of 13.47% (12.84 mL), 95% LOA of +24.85% (+23.64 mL) and -27.97% (-26.7 mL) and percent error = 26.2 %. For correlation analysis, the regression equation was y = 0.82x + 19.1 and correlation coefficient r(2) = 0.61 (r = 0.78). Bland-Altman analysis of averaged pre- and post-cMRI TBEV CO versus cMRI CO yielded a mean bias of 5.01% (0.32 L min(-1)), precision of 12.85% (0.77 L min(-1)), 95% LOA of +30.20 % (+0.1.83 L min(-1)) and -20.7% (-1.19 L min(-1)) and percent error = 24.8%. Regression analysis yielded y = 0.92x + 0.78, correlation coefficient r(2) = 0.74 (r = 0.86). TBEV is a novel, noninvasive method, which provides satisfactory estimates of SV and CO in normal humans.


Assuntos
Artéria Braquial/fisiologia , Débito Cardíaco/fisiologia , Cardiografia de Impedância/métodos , Volume Sistólico/fisiologia , Adulto , Cardiografia de Impedância/instrumentação , Cardiografia de Impedância/estatística & dados numéricos , Desenho de Equipamento , Feminino , Humanos , Modelos Lineares , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reologia/instrumentação , Reologia/métodos , Reologia/estatística & dados numéricos
5.
Pacing Clin Electrophysiol ; 37(5): 554-61, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24341570

RESUMO

BACKGROUND: The complex relationship between heart failure and atrial tachyarrhythmias (AT/atrial fibrillation [AF]) is not well understood. We examined the temporal association between changes in intrathoracic impedance, suggesting thoracic fluid accumulation, and AT/AF occurrence in cardiac resynchronization therapy-defibrillator and implantable cardioverter defibrillator (ICD) patients. METHODS: A retrospective analysis was conducted on stored implantable device data to identify patients with automatic monitoring of daily AT/AF burden and intrathoracic impedance. Daily population trends in AT/AF burden before and after a fluid index threshold crossing (FIC) were determined. RESULTS: A total of 73,018 patients (68 ± 12 years, 51% ICD, 75% male) were evaluated over 18.6 ± 11.5 months. Kaplan-Meier analysis indicated a significantly higher probability of FIC events in the first month following the onset of persistent AT/AF when compared to a matched group without persistent AT/AF (hazard ratio [HR] 1.65, 95% confidence interval [CI] [1.58, 1.72], P < 0.001). Conversely, patients were significantly more likely to experience an episode of persistent AF in the first month after the FIC event (HR 1.32, 95% CI [1.08, 1.63], P = 0.008). The probability of a fluid index crossing within 30 days of the onset of persistent AT/AF was significantly lower in a subgroup of patients with adequate rate control (35.8% [34.3-37.4%] vs 42.0% [39.6-44.6%]; HR 1.24 [1.13-1.36]). CONCLUSION: Thoracic fluid accumulation, as indicated by decreasing intrathoracic impedance, was more likely to occur immediately after the onset of persistent AT/AF, especially in the presence of inadequate rate control. Likewise, the onset of persistent AT/AF was more likely following a decrease in intrathoracic impedance.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Dispositivos de Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Desfibriladores Implantáveis/estatística & dados numéricos , Derrame Pleural/diagnóstico , Derrame Pleural/epidemiologia , Idoso , Cardiografia de Impedância/estatística & dados numéricos , Causalidade , Comorbidade , Feminino , Insuficiência Cardíaca , Humanos , Incidência , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Estados Unidos/epidemiologia
6.
Pacing Clin Electrophysiol ; 36(8): 994-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23594286

RESUMO

BACKGROUND: The utility of cardiac device-based intrathoracic monitoring (OptiVol, Medtronic Inc., Minneapolis, MN, USA) for congestive heart failure (CHF) exacerbation has not been evaluated in pediatric or congenital heart disease patients. METHODS: This was a retrospective study of all patients at a single center with an endocardial OptiVol capable device. OptiVol index values were collected in 2-week bins from January 2007 to December 2010. The clinical outcomes were CHF exacerbation defined as hospitalization or medication change for CHF and device-treated ventricular arrhythmia based on remote or in-office device interrogation. Clinical and OptiVol data were collected by separate investigators blinded to the other parameter. OptiVol data were correlated to the clinical outcomes to determine sensitivity and predictability for multiple threshold values in the entire cohort and pediatric and congenital subgroups. RESULTS: Forty-seven patients were included. A total of 1,106 months of OptiVol data were collected. Median age of the cohort was 18 years (range 6-58 years). There were 23 pediatric, median age 13 years (range 6-16), at device implant, and 18 patients, median age 31 years (range 13-58), considered at risk for heart failure at implant. There were three heart failure exacerbations and 17 treated ventricular arrhythmias. The study population-specific positive predictive value (PPV) of OptiVol was low (sensitivity 33% and PPV ≤4.4%) for both CHF exacerbation and arrhythmias in all analyzed groups. CONCLUSIONS: The sensitivity and positive predictive value of intrathoracic impedance monitoring was low in this population of adult congenital and pediatric patients. Recent improvements to the OptiVol algorithm may decrease these deficiencies.


Assuntos
Cardiografia de Impedância/estatística & dados numéricos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Adolescente , Adulto , Criança , Feminino , Cardiopatias Congênitas/epidemiologia , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Michigan/epidemiologia , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
7.
J Pain Symptom Manage ; 46(3): 433-446.e6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23200189

RESUMO

CONTEXT: Decisions surrounding the administration of clinically assisted hydration to patients dying of cancer can be challenging because of the limited understanding of hydration in advanced cancer and a lack of evidence to guide health care professionals. Bioelectrical impedance analysis (BIA) has been used to assess hydration in various patient groupings, but evidence for its use in advanced cancer is limited. OBJECTIVES: To critically appraise existing methods of hydration status assessment in advanced cancer and review the potential for BIA to assess hydration in advanced cancer. METHODS: Searches were carried out in four electronic databases. A hand search of selected peer-reviewed journals and conference abstracts also was conducted. Studies reporting (de)hydration assessment (physical examination, biochemical measures, symptom assessment, and BIA) in patients with advanced cancer were included. RESULTS: The results highlight how clinical examination and biochemical tests are standard methods of assessing hydration, but limitations exist with these methods in advanced cancer. Furthermore, there is disagreement over the evidence for some commonly associated symptoms with dehydration in cancer. Although there are limitations with using BIA alone to assess hydration in advanced cancer, analysis of BIA raw measurements through the method of bioelectrical impedance vector analysis may have a role in this population. CONCLUSION: The benefits and burdens of providing clinically assisted hydration to patients dying of cancer are unclear. Bioelectrical impedance vector analysis shows promise as a hydration assessment tool but requires further study in advanced cancer. Innovative methodologies for research are required to add to the evidence base and ultimately improve the care for the dying.


Assuntos
Cardiografia de Impedância/métodos , Desidratação/epidemiologia , Desidratação/enfermagem , Hidratação/estatística & dados numéricos , Neoplasias/diagnóstico , Neoplasias/enfermagem , Avaliação de Resultados em Cuidados de Saúde/métodos , Cardiografia de Impedância/estatística & dados numéricos , Causalidade , Comorbidade , Medicina Baseada em Evidências , Humanos , Neoplasias/epidemiologia , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
8.
Am J Physiol Heart Circ Physiol ; 301(4): H1389-95, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21803948

RESUMO

We investigated the system identification approach for potentially improved estimation of pulse transit time (PTT), a popular arterial stiffness marker. In this approach, proximal and distal arterial waveforms are measured and respectively regarded as the input and output of a system. Next, the system impulse response is identified from all samples of the measured input and output. Finally, the time delay of the impulse response is detected as the PTT estimate. Unlike conventional foot-to-foot detection techniques, this approach is designed to provide an artifact robust estimate of the true PTT in the absence of wave reflection. The approach is also applicable to arbitrary types of arterial waveforms. We specifically applied a parametric system identification technique to noninvasive impedance cardiography (ICG) and peripheral arterial blood pressure waveforms from 15 humans subjected to lower-body negative pressure. We assessed the technique through the correlation coefficient (r) between its 1/PTT estimates and measured diastolic pressure (DP) per subject and the root mean squared error (RMSE) of the DP predicted from these estimates and measured DP. The technique achieved average r and RMSE values of 0.81 ± 0.16 and 4.3 ± 1.3 mmHg. For comparison, the corresponding values were 0.59 ± 0.37 (P < 0.05) and 5.9 ± 2.5 (P < 0.01) mmHg for the conventional technique applied to the same waveforms and 0.28 ± 0.40 (P < 0.001) and 7.2 ± 1.8 (P < 0.001) mmHg for the conventional technique with the ECG waveform substituted for the ICG waveform. These results demonstrate, perhaps for the first time, that the system identification approach can indeed improve PTT estimation.


Assuntos
Artérias/fisiologia , Pressão Sanguínea/fisiologia , Cardiografia de Impedância/métodos , Algoritmos , Cardiografia de Impedância/estatística & dados numéricos , Eletrocardiografia , Feminino , Pé/irrigação sanguínea , Humanos , Pressão Negativa da Região Corporal Inferior , Masculino , Fluxo Pulsátil/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Reprodutibilidade dos Testes , Resistência Vascular/fisiologia , Adulto Jovem
9.
Heart Fail Rev ; 16(5): 491-502, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21424278

RESUMO

Acute heart failure syndromes (AHFS) represent the most common discharge diagnoses in adults over age 65 and translate into dramatically increased heart failure-associated morbidity and mortality. Conventional approaches to the early detection of pulmonary and systemic congestion have been shown to be of limited sensitivity. Despite their proven efficacy, disease management and structured telephone support programs have failed to achieve widespread use in part due to their resource intensiveness and reliance upon motivated patients. While once thought to hold great promise, results from recent prospective studies on telemonitoring strategies have proven disappointing. Implantable devices with their capacity to monitor electrophysiologic and hemodynamic parameters over long periods of time and with minimal reliance on patient participation may provide solutions to some of these problems. Conventional electrophysiologic parameters and intrathoracic impedance data are currently available in the growing population of heart failure patients with equipped devices. A variety of implantable hemodynamic monitors are currently under investigation. How best to integrate these devices into a systematic approach to the management of patients before, during, and after AHFS is yet to be established.


Assuntos
Cateterismo Cardíaco , Cardiografia de Impedância , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Edema Pulmonar/prevenção & controle , Tecnologia de Sensoriamento Remoto , Doença Aguda , Idoso , Volume Sanguíneo , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/estatística & dados numéricos , Cardiografia de Impedância/instrumentação , Cardiografia de Impedância/métodos , Cardiografia de Impedância/estatística & dados numéricos , Gerenciamento Clínico , Diagnóstico Precoce , Eficiência Organizacional , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Desenho de Equipamento , Estudos de Avaliação como Assunto , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Hemodinâmica , Humanos , Participação do Paciente , Serviços Preventivos de Saúde/organização & administração , Edema Pulmonar/diagnóstico , Edema Pulmonar/etiologia , Edema Pulmonar/fisiopatologia , Tecnologia de Sensoriamento Remoto/classificação , Tecnologia de Sensoriamento Remoto/instrumentação , Tecnologia de Sensoriamento Remoto/métodos , Risco Ajustado , Revisão da Utilização de Recursos de Saúde
10.
Psychophysiology ; 47(6): 1087-93, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20409019

RESUMO

Impedance cardiography is a technique commonly used in psychophysiological studies. However, concerns about the utility of full circumferential band electrodes (FB) have been raised. The current study was designed to compare FB with a three-quarter circumferential band configuration (PB). A total of 47 participants (66% female, mean [SD] age=20.4 [3.0] years) underwent 2 testing sessions, once using FB and once using PB. Session order was randomized and balanced. Each session consisted of 5 min of rest, math task, recovery, and cold pressor test. Average baseline and task pre-ejection period (PEP), stroke volume (SV), cardiac output (CO), heart rate (HR), blood pressure (BP), and total peripheral resistance (TPR) was calculated from impedance cardiography and blood pressure monitoring. Participants were are asked to rate measures of comfort after each session. There were no significant difference between the mean levels of PEP, SV, CO, HR, and TPR for the PB versus the FB configurations. However, both systolic BP and diastolic BP were higher during the FB session. Intraclass correlations were high (r(icc) =.63-.93) between PB and FB. Bland-Altman analyses revealed a low level of bias (≤5%) between the configurations. Based on limits of agreement between ±30%, there was equivalence in PEP between the 2 configurations, and SV, CO, and TPR were close to reaching equivalence. Participants clearly indicated greater comfort with the PB configuration compared to the FB. The current study provides incremental evidence that suggests a three-quarter PB configuration may be utilized for standard psychophysiological testing instead of the standard FB configuration. However, further studies are needed to validate the PB configuration against other techniques.


Assuntos
Cardiografia de Impedância/métodos , Análise de Variância , Cardiografia de Impedância/estatística & dados numéricos , Temperatura Baixa , Interpretação Estatística de Dados , Eletrodos , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Medição da Dor , Pressão , Processamento de Sinais Assistido por Computador , Estresse Psicológico/fisiopatologia , Adulto Jovem
12.
Artigo em Inglês | MEDLINE | ID: mdl-19964459

RESUMO

The Cardiac Output (CO) can be calculated from the thoracic cardio-impedance signal from several methods, and all of them are linked to the frequency information, information that is limited by the type of filtering used before. A methodology is proposed to evaluate the effect of the commonly used methods of filtering, and an improvement of the SFLC LMS-based algorithm by the use of RLS algorithm is also tested. Performances of algorithms are then evaluated considering different types of noise such as white noise or combination of sinusoidal noises to simulate the effect of respiration and body movements.


Assuntos
Cardiografia de Impedância/estatística & dados numéricos , Algoritmos , Engenharia Biomédica , Débito Cardíaco , Análise de Fourier , Humanos
13.
Am J Perinatol ; 26(10): 717-21, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19452431

RESUMO

We assessed the effect of antihypertensive therapy guided by impedance cardiography on maternal and fetal outcomes in pregnancies at risk for hypertensive complications. We performed a retrospective review of the outcomes of 318 singleton pregnancies with chronic hypertension or prior preterm delivery due to preeclampsia whose antihypertensive therapy was guided by impedance cardiography. Hemodynamic subsets were compared using analysis of variance. Impedance cardiography was used to evaluate cardiac output and total peripheral resistance starting at less than 24 weeks. All patients received atenolol; 24% required additional therapy with a vasodilator. The mean gestational age at delivery was 37 +/- 2 weeks. Preeclampsia developed in 14%. The incidence of birth weight less than the 10th percentile was 10%. There were no perinatal deaths, and 75% of the infants spent <3 days in the hospital. Hyperdynamic patients had less preeclampsia, less severe preeclampsia, fewer deliveries <34 weeks, and fewer neonatal intensive care unit days compared with those requiring a vasodilator. Antihypertensive therapy guided by hemodynamic information results in pregnancies delivering at or near term, little preeclampsia, and no increase in growth restriction. Hyperdynamic patients have better outcomes than patients with increased total peripheral resistance.


Assuntos
Anti-Hipertensivos/uso terapêutico , Pré-Eclâmpsia/diagnóstico , Pré-Eclâmpsia/tratamento farmacológico , Complicações Cardiovasculares na Gravidez/diagnóstico , Complicações Cardiovasculares na Gravidez/tratamento farmacológico , Resultado da Gravidez/epidemiologia , Adulto , Atenolol/uso terapêutico , Cardiografia de Impedância/estatística & dados numéricos , Feminino , Hemodinâmica , Humanos , Recém-Nascido , Pré-Eclâmpsia/epidemiologia , Gravidez , Complicações Cardiovasculares na Gravidez/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Vasodilatadores/uso terapêutico , Adulto Jovem
14.
Pacing Clin Electrophysiol ; 32(3): 363-70, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19272067

RESUMO

PURPOSE: Some implantable cardioverter-defibrillators (ICDs) are now able to monitor intrathoracic impedance. The aim of the study was to describe the use of such monitoring in clinical practice and to evaluate the clinical impact of the fluid accumulation alert feature of these ICDs. METHODS AND RESULTS: Five hundred thirty-two heart failure (HF) patients implanted with these ICDs were followed up for 11 +/- 7 months. A clinical event (CE) was deemed to have occurred if it resulted in hospitalization or milder manifestations of HF deterioration. Three hundred sixty-two acute decreases in intrathoracic impedance (Z events) occurred in 230 patients. Of these episodes, 171 (47%) were associated with a CE within 2 weeks of the Z event. In another 71 (20%) Z events, drug therapy was adjusted despite the absence of overt signs of clinical deterioration. The rate of unexplained Z events was 0.25 per patient-year and 25 hospitalizations were not associated with Z events. The audible alert was disabled in a group of 102 patients (OFF group). HF hospitalizations occurred in 29 (7%) patients in the ON group and 20 (20%, P < 0.001) patients in the OFF group. The rate of combined cardiac death and HF hospitalization was lower in patients with Alert ON (log-rank test, P = 0.007). CONCLUSIONS: The ICD reliably detected CE and yielded low rates of unexplained and undetected events. The alert capability seemed to reduce the number of HF hospitalizations by allowing timely detection and therapeutic intervention.


Assuntos
Cardiografia de Impedância/estatística & dados numéricos , Desfibriladores Implantáveis/estatística & dados numéricos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Hospitalização/estatística & dados numéricos , Medição de Risco/métodos , Idoso , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Itália/epidemiologia , Masculino , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Resultado do Tratamento
15.
J Clin Monit Comput ; 22(2): 113-9, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18340540

RESUMO

OBJECTIVES: Bioreactance, the analysis of intrabeat variations in phase of a transthoracic voltage in response to an applied high frequency transthoracic current, was recently introduced for noninvasive cardiac output measurement (NICOM). We evaluated NICOM compared to thermo- dilution (TD) in several clinical settings. METHODS: 111 patients with a clinical indication for TD cardiac output (CO) measurement were recruited at five centers, including patients in cardiac catheterization laboratories, cardiac care units and intensive care units. CO measurements were made simulta- neously with TD and the bioreactance method and compared by regression analysis. RESULTS: For studies in the intensive care units, TD-based CO and NICOM were highly correlated (r = 0.78, P < 0.0001) and did not differ significantly from each other (P = 0.55). Results in the cardiac catheterization laboratory were similar (r = 0.71, P < 0.001; P = 0.28 NICOM versus TD). In subsets of patients, NICOM was shown to be better corre- lated with TD-CO than CO obtained with the Fick method or with standard bioimpedance-based measurements of CO. CONCLUSIONS: On average, compared to TD, bioreactance- based NICOM has acceptable accuracy in challenging clinical environments. Availability of such a tool may allow clinicians to have information about CO in patients where this information is not currently available to help diagnosis and guide therapy.


Assuntos
Débito Cardíaco , Cardiografia de Impedância , Termodiluição , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardiografia de Impedância/estatística & dados numéricos , Impedância Elétrica , Fenômenos Eletromagnéticos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Contração Miocárdica/fisiologia , Pulso Arterial , Análise de Regressão , Reprodutibilidade dos Testes , Termodiluição/estatística & dados numéricos
17.
J Biopharm Stat ; 17(4): 571-82, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17613642

RESUMO

Limits of agreement provide a straightforward and intuitive approach to agreement between different methods for measuring the same quantity. When pairs of observations using the two methods are independent, i.e., on different subjects, the calculations are very simple and straightforward. Some authors collect repeated data, either as repeated pairs of measurements on the same subject, whose true value of the measured quantity may be changing, or more than one measurement by one or both methods of an unchanging underlying quantity. In this paper we describe methods for analysing such clustered observations, both when the underlying quantity is assumed to be changing and when it is not.


Assuntos
Biometria/métodos , Técnicas de Laboratório Clínico/estatística & dados numéricos , Técnicas e Procedimentos Diagnósticos/estatística & dados numéricos , Algoritmos , Análise de Variância , Cardiografia de Impedância/estatística & dados numéricos , Humanos , Ventriculografia com Radionuclídeos/estatística & dados numéricos , Reprodutibilidade dos Testes , Volume Sistólico/fisiologia
18.
Psychophysiology ; 44(1): 113-9, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17241147

RESUMO

The B point on the impedance cardiograph waveform corresponds to the opening of the aortic valve and is an important parameter for calculating systolic time intervals, stroke volume, and cardiac output. Identifying the location of the B point is sometimes problematic because the characteristic upstroke that serves as a marker of this point is not always apparent. Here is presented a reliable method for B point identification, based on the consistent relationship between the R to B interval (RB) and the interval between the R-wave and the peak of the dZ/dt function (RZ). The polynomial function relating RB to RZ (RB = 1.233RZ - 0.0032RZ(2) - 31.59) accounts for 90%-95% of the variance in the B point location across ages and gender and across baseline and stress conditions. This relation affords a rapid approximation to B point measurement that, in noisy or degraded signals, is superior to visual B point identification and to a derivative-based estimate.


Assuntos
Cardiografia de Impedância/estatística & dados numéricos , Frequência Cardíaca/fisiologia , Adolescente , Adulto , Envelhecimento/fisiologia , Débito Cardíaco/fisiologia , Interpretação Estatística de Dados , Eletrocardiografia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia
19.
Circ J ; 70(11): 1462-5, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17062972

RESUMO

BACKGROUND: Clinical data suggest that changes in intrathoracic impedance and fluid accumulation in the lung are inversely related. METHODS AND RESULTS: Daily shock impedance (S-IMP) was evaluated in 29 patients in whom a Ventak Prizm 2 was implanted (61+/-14 years old). The mean follow-up period was 45+/-18 weeks, during which 6 patients had episodes of decompensated heart failure (DHF group) and the others did not (NHF group). There was no significant difference between the DHF group and NHF group in the mean value of the S-IMP (46.4 +/-3.3 vs 45.4+/-5.4 Omega). The range of S-IMP in individual patients in the DHF group was significantly greater than that in the NHF group (13.8+/-0.38 vs 7.0+/-3.1 Omega, p<0.0001). Mean weekly change of S-IMP in individual patients in the DHF group was significantly greater than that in the NHF group (1.583+/-0.630 vs 1.092+/-0.361 Omega, p<0.0176). When the cut-off value was set at >1.242 Omega, sensitivity was 100% and specificity was 69.6% for a diagnosis of DHF. There was a significant negative correlation between the percent increases in brain natriuretic peptide (BNP) and S-IMP (correlation coefficient: -0.775 p<0.0001) in the DHF group. There was an inverse relation between BNP and S-IMP. CONCLUSIONS: Measurement of shock impedance may be useful in the management of congestive heart failure.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Cardiografia de Impedância/métodos , Cardiografia de Impedância/estatística & dados numéricos , Desfibriladores Implantáveis/estatística & dados numéricos , Feminino , Insuficiência Cardíaca/sangue , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Edema Pulmonar/fisiopatologia , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
Int J Artif Organs ; 29(6): 564-72, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16841284

RESUMO

BACKGROUND: Hemodialysis patients experience a variety of hemodynamic abnormalities that contribute to cardiovascular disease mortality which is the leading cause of death in these patients. Impedance cardiography has been utilized in order to monitor cardiac hemodynamics with lower cost and inconvenience, but it has not been appropriately validated in the hemodialysis population. AIM: We repeatedly used impedance cardiography to assess short- (48 hours) and long-term (15 days) reproducibility of cardiac output measurements and we compared baseline impedance cardiography measurements with echocardiographic measurements. PATIENTS AND METHODS: We studied 109 stable hemodialysis patients, aged 59.70 +/- 11.97 years being on hemodialysis for 67.59 +/- 40.15 months, on a non-dialysis day. Cardiac output was obtained with the BioZ impedance cardiography system (Cardiodynamics, San Diego, Ca, USA). Baseline echocardiography was performed using a Hewlett-Packard Sonos 2500 (Andover, Mass., USA). RESULTS: The values of impedance cardiography derived cardiac output were 5.28 +/- 0.79, 5.27 +/- 0.75 and 5.25 +/- 0.74 l/min at baseline (107 patients), 48 hours (107 patients) and 15 days (98 patients) respectively, showing high reproducibility. Bland and Altman analysis estimated that bias at 48 hours and at 15 days were: -0.013 (95% confidence intervals = -0.045 to 0.019) and 0.028, (95% confidence intervals = -0.044 to 0.101), respectively. In addition baseline impedance cardiography derived cardiac output was significantly correlated with the echocardiographic derived cardiac output (r = 0.9, p < 0.0001). CONCLUSION: Impedance cardiography is a simple non invasive technique for cardiac output estimation in hemodialysis patients which has high reproducibility when performed under controlled conditions, and is closely correlated with echocardiographic measurements of cardiac output.


Assuntos
Débito Cardíaco , Cardiografia de Impedância , Ecocardiografia , Diálise Renal , Idoso , Cardiografia de Impedância/métodos , Cardiografia de Impedância/estatística & dados numéricos , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/fisiopatologia , Estudos de Coortes , Ecocardiografia/estatística & dados numéricos , Ecocardiografia Doppler/estatística & dados numéricos , Feminino , Humanos , Falência Renal Crônica/complicações , Falência Renal Crônica/fisiopatologia , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...