Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.526
Filtrar
1.
Methods Mol Biol ; 2829: 271-275, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38951343

RESUMO

This chapter outlines a rapid detection method to determine the virus titer of your baculovirus stock. Staining of cells with fluorescently labeled gp64 antibody allows for flow cytometer-based quantitation of baculovirus-infected insect cells. In this assay, Sf9 cells are infected with tenfold serial dilutions of the test virus stock, and baculovirus titers are calculated based on the ratio of infected to uninfected cells 13 to 18 h after inoculation.


Assuntos
Baculoviridae , Citometria de Fluxo , Citometria de Fluxo/métodos , Baculoviridae/genética , Animais , Células Sf9 , Carga Viral/métodos
2.
Methods Mol Biol ; 2829: 267-270, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38951342

RESUMO

There are many methods that can be used to determine the infectious titer of your baculovirus stock. The TCID50 method is a simple end-point dilution method that determines the amount of baculovirus virus needed to produce a cytopathic effect or kill 50% of inoculated insect cells. Serial dilutions of baculovirus stock are added to Sf9 cells cultivated in 96-well plates and 3-5 days after infection, cells are monitored for cell death or cytopathic effect. The titer can then be calculated by the Reed-Muench method as described in this method.


Assuntos
Baculoviridae , Baculoviridae/genética , Animais , Células Sf9 , Efeito Citopatogênico Viral , Spodoptera/virologia , Carga Viral/métodos , Linhagem Celular
3.
Front Cell Infect Microbiol ; 14: 1422299, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38988808

RESUMO

Objectives: Precise HDV-RNA detection and quantification are pivotal for diagnosis and monitoring of response to newly approved treatment. We evaluate the performance of three HDV RNA detection and quantification assays. Methods: Hepatitis Delta RT-PCR system kit, EurobioPlex HDV assay, and RoboGene HDV RNA Quantification kit 2.0 were used for testing 151 HBsAg-positive samples, 90 HDV-RNA negative and 61 HDV-RNA positive. We also evaluated serial dilutions of the WHO international standard for HDV, PEI 7657/12. All HDV-RNA positive samples were genotyped using a next-generation sequencing strategy. Results: Qualitative results indicated a 100% concordance between tests. Quantitative results correlated well, r2 = 0.703 (Vircell-vs-Eurobio), r2 = 0.833 (Vircell-vs-RoboGene), r2 = 0.835 (Robogene-vs-Eurobio). Bias index was 2.083 (Vircell-vs-Eurobio), -1.283 (Vircell-vs-RoboGene), and -3.36 (Robogene-vs-Eurobio). Using the WHO IS, Vircell overestimated the viral load by 0.98 log IU/mL, Eurobio by 1.46 log IU/mL, and RoboGene underestimated it by 0.98 log IU/mL. Fifty-nine samples were successfully genotyped (Genotype 1, n=52; Genotype 5, n=7; Genotype 6, n=1), with similar results for correlation and bias. Conclusion: This study underscores the necessity of using reliable HDV-RNA detection and quantification assays, as evidenced by the high concordance rates in qualitative detection and the observed variability in quantitative results. These findings highlight the importance of consistent assay use in clinical practice to ensure accurate diagnosis and effective treatment monitoring of HDV infection.


Assuntos
Genótipo , Hepatite D , Vírus Delta da Hepatite , RNA Viral , Carga Viral , Vírus Delta da Hepatite/genética , Vírus Delta da Hepatite/isolamento & purificação , Humanos , RNA Viral/genética , Carga Viral/métodos , Hepatite D/diagnóstico , Hepatite D/virologia , Kit de Reagentes para Diagnóstico/normas , Sensibilidade e Especificidade , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Técnicas de Diagnóstico Molecular/métodos
4.
Viruses ; 16(6)2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38932255

RESUMO

Quantification of Torquetenovirus (TTV) viremia is becoming important for evaluating the status of the immune system in solid organ transplant recipients, monitoring the appearance of post-transplant complications, and controlling the efficacy of maintenance immunosuppressive therapy. Thus, diagnostic approaches able to scale up TTV quantification are needed. Here, we report on the development and validation of a real-time PCR assay for TTV quantification on the Hologic Panther Fusion® System by utilizing its open-access channel. The manual real-time PCR previously developed in our laboratories was optimized to detect TTV DNA on the Hologic Panther Fusion® System. The assay was validated using clinical samples. The automated TTV assay has a limit of detection of 1.6 log copies per ml of serum. Using 112 samples previously tested via manual real-time PCR, the concordance in TTV detection was 93% between the assays. When the TTV levels were compared, the overall agreement between the methods, as assessed using Passing-Bablok linear regression and Bland-Altman analyses, was excellent. In summary, we validated a highly sensitive and accurate method for the diagnostic use of TTV quantification on a fully automated Hologic Panther Fusion® System. This will greatly improve the turnaround time for TTV testing and better support the laboratory diagnosis of this new viral biomarker.


Assuntos
Infecções por Vírus de DNA , Reação em Cadeia da Polimerase em Tempo Real , Carga Viral , Viremia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Viremia/diagnóstico , Viremia/virologia , Humanos , Carga Viral/métodos , Infecções por Vírus de DNA/diagnóstico , Infecções por Vírus de DNA/virologia , Sensibilidade e Especificidade , Torque teno virus/genética , Torque teno virus/isolamento & purificação , DNA Viral/genética , DNA Viral/sangue , Limite de Detecção , Reprodutibilidade dos Testes , Automação Laboratorial/métodos
5.
Int J Mol Sci ; 25(12)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38928410

RESUMO

Chikungunya virus (Togaviridae, Alphavirus; CHIKV) is a mosquito-borne global health threat. The main urban vector of CHIKV is the Aedes aegypti mosquito, which is found throughout Brazil. Therefore, it is important to carry out laboratory tests to assist in the virus's diagnosis and surveillance. Most molecular biology methodologies use nucleic acid extraction as the first step and require quality RNA for their execution. In this context, four RNA extraction protocols were evaluated in Ae. aegypti experimentally infected with CHIKV. Six pools were tested in triplicates (n = 18), each containing 1, 5, 10, 20, 30, or 40 mosquitoes per pool (72 tests). Four commercial kits were compared: QIAamp®, Maxwell®, PureLink®, and PureLink® with TRIzol®. The QIAamp® and PureLink® with TRIzol® kits had greater sensitivity. Two negative correlations were observed: as the number of mosquitoes per pool increases, the Ct value decreases, with a higher viral load. Significant differences were found when comparing the purity and concentration of RNA. The QIAamp® protocol performed better when it came to lower Ct values and higher RNA purity and concentration. These results may provide help in CHIKV entomovirological surveillance planning.


Assuntos
Aedes , Febre de Chikungunya , Vírus Chikungunya , Mosquitos Vetores , RNA Viral , Vírus Chikungunya/isolamento & purificação , Vírus Chikungunya/genética , Aedes/virologia , Animais , RNA Viral/isolamento & purificação , RNA Viral/genética , Mosquitos Vetores/virologia , Febre de Chikungunya/virologia , Febre de Chikungunya/diagnóstico , Carga Viral/métodos
6.
Microbiol Spectr ; 12(7): e0420123, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38842363

RESUMO

Quantitation of cytomegalovirus (CMV) DNA load in specimens other than blood such as bronchoalveolar lavages, intestinal biopsies, or urine has become a common practice as an ancillary tool for the diagnosis of CMV pneumonitis, intestinal disease, or congenital infection, respectively. Nevertheless, most commercially available CMV PCR platforms have not been validated for CMV DNA detection in these specimen types. In this study, a laboratory-developed test based on Alinity m CMV ("Alinity LDT") was evaluated. Reproducibility assessment using spiked bronchial aspirate (BAS) or urine samples showed low standard deviations of 0.08 and 0.27 Log IU/mL, respectively. Evaluating the clinical performance of Alinity LDT in comparison to a laboratory-developed test based on RealTime CMV ("RealTime LDT") showed good concordance across 200 clinical specimens including respiratory specimens, intestinal biopsies, urine, and stool. A high Pearson's correlation coefficient of r = 0.92, a low mean bias of -0.12 Log IU/mL, a good qualitative agreement of 90%, and a Cohen's kappa value of 0.76 (substantial agreement) were observed. In separate analyses of the sample types BAS, tracheal aspirates, bronchoalveolar lavage, biopsies, and urine, the assay results correlated well between the two platforms with r values between 0.88 and 0.99 and a bias <0.5 Log IU/mL. Overall, the fully automated, continuous, random access Alinity LDT yielded good reproducibility, high concordance, and good correlation to RealTime LDT in respiratory, gastrointestinal, and urine samples and may enhance patient management with rapid result reporting.IMPORTANCEIn transplant recipients, a major cause for morbidity and mortality is end-organ disease by primary or secondary CMV infection of the respiratory or gastrointestinal tract. In addition, sensorineural hearing loss and neurodevelopmental abnormalities are frequent sequelae of congenital CMV infections in newborns. Standard of care for highly sensitive detection and quantitation of the CMV DNA load in plasma and whole blood specimens is real-time PCR testing. Beyond that, there is a need for quantitative determination of CMV DNA levels in respiratory, gastrointestinal, and urinary tract specimens using a highly automated, random access CMV PCR assay with a short turnaround time to enable early diagnosis and treatment. In the present study, clinical performance of the fully automated Alinity m analyzer in comparison to the current RealTime LDT assay was evaluated in eight different off-label sample types.


Assuntos
Infecções por Citomegalovirus , Citomegalovirus , DNA Viral , Trato Gastrointestinal , Humanos , Citomegalovirus/isolamento & purificação , Citomegalovirus/genética , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/virologia , DNA Viral/genética , DNA Viral/isolamento & purificação , Reprodutibilidade dos Testes , Trato Gastrointestinal/virologia , Carga Viral/métodos , Sistema Respiratório/virologia , Líquido da Lavagem Broncoalveolar/virologia , Sensibilidade e Especificidade
7.
Int J Mol Sci ; 25(11)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38892344

RESUMO

SARS-CoV-2 is a highly infectious virus responsible for the COVID-19 pandemic. Therefore, it is important to assess the risk of SARS-CoV-2 infection, especially in persistently positive patients. Rapid discrimination between infectious and non-infectious viruses aids in determining whether prevention, control, and treatment measures are necessary. For this purpose, a method was developed and utilized involving a pre-treatment with 50 µM of propidium monoazide (PMAxx, a DNA intercalant) combined with a digital droplet PCR (ddPCR). The ddPCR method was performed on 40 nasopharyngeal swabs (NPSs) both before and after treatment with PMAxx, revealing a reduction in the viral load at a mean of 0.9 Log copies/mL (SD ± 0.6 Log copies/mL). Furthermore, six samples were stratified based on the Ct values of SARS-CoV-2 RNA (Ct < 20, 20 < Ct < 30, Ct > 30) and analyzed to compare the results obtained via a ddPCR with viral isolation and a negative-chain PCR. Of the five samples found positive via a ddPCR after the PMAxx treatment, two of the samples showed the highest post-treatment SARS-CoV-2 loads. The virus was isolated in vitro from both samples and the negative strand chains were detected. In three NPS samples, SARS CoV-2 was present post-treatment at a low level; it was not isolated in vitro, and, when detected, the strand was negative. Our results indicate that the established method is useful for determining whether the SARS-CoV-2 within positive NPS samples is intact and capable of causing infection.


Assuntos
Azidas , COVID-19 , Nasofaringe , Propídio , SARS-CoV-2 , Carga Viral , Humanos , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Azidas/química , Propídio/análogos & derivados , Propídio/química , COVID-19/virologia , Carga Viral/métodos , Nasofaringe/virologia , RNA Viral/genética , RNA Viral/isolamento & purificação , Teste de Ácido Nucleico para COVID-19/métodos , Reação em Cadeia da Polimerase/métodos
9.
Microbiol Spectr ; 12(7): e0001824, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38757960

RESUMO

Monkeypox virus (MPXV) poses a global health threat. Droplet digital PCR (ddPCR) holds potential as an accurate diagnostic tool for clinical microbiology. However, there is limited literature on the applicability of ddPCR in clinical settings. In this study, the clinical features of patients with MPXV during the initial outbreak in China in June 2023 were reviewed, and an optimized ddPCR method with dilution and/or inhibitor removal was developed to enhance MPXV detection efficiency. Eighty-two MPXV samples were tested from nine different clinical specimen types, including feces, urine, pharyngeal swabs, anal swabs, saliva, herpes fluid, crust, and semen, and the viral load of each specimen was quantified. A comparative analysis was performed with qPCR to assess sensitivity and specificity and to investigate the characteristics of MPXV infection by analyzing viral loads in different clinical specimens. Consequently, common pharyngeal and gastrointestinal symptoms were observed in patients with MPXV. The optimized ddPCR method demonstrated relatively high sensitivity for MPXV quantification in the clinical materials, with a limit of detection of 0.1 copies/µL. This was particularly evident in low-concentration samples like whole blood, semen, and urine. The optimized ddPCR demonstrated greater detection accuracy compared with normal ddPCR and qPCR, with an area under the curve (AUC) of 0.939. Except for crust samples, viral loads in the specimens gradually decreased as the disease progressed. Virus levels in feces and anal swabs kept a high detection rate at each stage of post-symptom onset, and feces and anal swabs samples may be suitable for clinical diagnosis and continuous monitoring of MPXV. IMPORTANCE: The ddPCR technique proved to be a sensitive and valuable tool for accurately quantifying MPXV viral loads in various clinical specimen types. The findings provided valuable insights into the necessary pre-treatment protocols for MPXV diagnosis in ddPCR detection and the potentially suitable sample types for collection. Therefore, such results can aid in comprehending the potential characteristics of MPXV infection and the usage of ddPCR in clinical settings.


Assuntos
Monkeypox virus , Sensibilidade e Especificidade , Carga Viral , Humanos , Carga Viral/métodos , Monkeypox virus/isolamento & purificação , Monkeypox virus/genética , China , Mpox/diagnóstico , Mpox/virologia , Masculino , Fezes/virologia , Feminino , Reação em Cadeia da Polimerase/métodos , Surtos de Doenças , Adulto , Reação em Cadeia da Polimerase em Tempo Real/métodos
10.
Diagn Microbiol Infect Dis ; 109(4): 116357, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38776663

RESUMO

We aimed to compare the NeuMoDx HBV Assay with the artus HBV Assay using residual plasma samples and to evaluate the discordant results. The study included 200 patient samples analyzed with the NMD assay and stored at -80 °C. Samples were analyzed by artus in 2023. Discordant results were evaluated by cobas 6800 HBV DNA Test. Excellent agreement was found between both tests. Of the 100 samples that were HBV DNA negative by NMD, 93 were negative and 7 were positive by artus. With the Cobas test, 5 samples were positive. Of the100 HBV DNA positive samples detected by NMD, 99 were positive with the artus assay. This sample was also HBV DNA negative by the Cobas test. The sensitivity and specificity of NeuMoDx were found 93 % and 99 %, respectively. There was excellent qualitative agreement and strong quantitative correlation between the NeuMoDx and artus assays for HBV DNA detection and quantitation.


Assuntos
DNA Viral , Vírus da Hepatite B , Hepatite B , Sensibilidade e Especificidade , Humanos , DNA Viral/sangue , Vírus da Hepatite B/genética , Vírus da Hepatite B/isolamento & purificação , Hepatite B/diagnóstico , Hepatite B/virologia , Hepatite B/sangue , Carga Viral/métodos , Kit de Reagentes para Diagnóstico/normas , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Plasma/virologia
11.
Microbiol Spectr ; 12(7): e0003024, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38771037

RESUMO

Quantitative monitoring of cytomegalovirus (CMV) DNAemia in venous blood is standard in solid organ transplant recipients (SOTr) but is limited by the need for phlebotomy facilities and personnel. The aim of the study was to evaluate the Tasso+ capillary blood (CB) self-collection device for quantitation of plasma CMV DNAemia. Thirty adult SOTr with suspected CMV DNAemia were enrolled to have a supervised Tasso+ CB sample collection within 24 h of a venous sample. CMV DNA was quantitated in paired samples by using the Abbott M2000 Real-Time qPCR instrument. The participants were provided with a study-specific survey that measured patient acceptability of the Tasso+ device compared with venipuncture. A Tasso + CB sample was successfully collected in 28/30 (93%) patients, and 44 paired samples were analyzed. Concordance for detection of CMV DNAemia above the limit of detection (LOD) was 91% (42/44), and the Tasso + CB sample was estimated to be 95% sensitive at a viral load (VL) of 308 IU/mL. Among samples with a quantifiable DNAemia result with both methods (N = 31), there was excellent correlation between methods (Spearman R2 = 0.99). The difference in CMV VL between venous and Tasso+ CB samples was not dependent on time (P > 0.1). Of 12 who completed the survey, 11 (92%) expressed a preference for Tasso+ CB collection over venipuncture. Collection of CB with the Tasso+ device is feasible, patient-acceptable, and yields generally comparable CMV DNAemia load to standard venous samples, but with lower sensitivity. Future studies to optimize and evaluate this methodology for patient self-collected samples are warranted. IMPORTANCE: We evaluate an FDA-cleared blood self-collection device (Tasso+) and demonstrate that it is patient-acceptable and yields a liquid blood sample with quantitative CMV DNAemia results comparable to those of standard venipuncture samples. This opens up possibilities for self-blood collection to monitor for CMV and potentially other viruses in transplant and other at-risk populations.


Assuntos
Infecções por Citomegalovirus , Citomegalovirus , DNA Viral , Transplante de Órgãos , Transplantados , Carga Viral , Humanos , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/sangue , Infecções por Citomegalovirus/virologia , DNA Viral/sangue , Citomegalovirus/isolamento & purificação , Citomegalovirus/genética , Pessoa de Meia-Idade , Masculino , Feminino , Adulto , Carga Viral/métodos , Idoso , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/instrumentação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Viremia/virologia , Viremia/diagnóstico
12.
J Clin Virol ; 173: 105680, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38728796

RESUMO

BACKGROUND: Epstein-Barr Virus (EBV) viral loads in hematopoietic stem cell transplant (HSCT) recipients are typically monitored using quantitative molecular assays. The Cobas EBV test (Roche Molecular, Pleasanton, CA) has recently been FDA-cleared for the monitoring of EBV viral loads in plasma samples of transplant patients. In this study, we compared the viral loads obtained by a laboratory-developed test (EBV LDT) using Altona Analyte specific reagents (ASR) to those obtained on the Cobas EBV test. METHODS: The analytical performance of the assay was established using the EBV verification panel from Exact Diagnostics and the EBV ATCC strain B95-8. The clinical evaluation was performed using 343 plasma samples initially tested on the EBV LDT. RESULTS: The analytical sensitivity (<18.8 IU/mL), precision (SD < 0.17 log) and linear range (35.0 IU/mL to 1E + 08 IU/mL) of the Cobas EBV assay established by the manufacturers were confirmed. The strength of the qualitative agreement was substantial between the cobas EBV and the EBV LDT (85.6 %; κ = 0.71) and almost perfect when discordant results were resolved (96.4 %; κ = 0.93). The quantitative agreement was moderate (82.9 %; κ = 0.53) with the viral load obtained on the Cobas EBV test being lower across the linear range of the two tests (mean log difference of 1.0). While the absolute values of the viral loads were markedly different, the overall trends observed in patients with multiple consecutive results were similar between the two tests. CONCLUSIONS: The Cobas EBV test provides an accurate and valid, in vitro diagnostic (IVD) option for monitoring of EBV viral loads in transplant patients and should provide an opportunity for increased standardization and commutability of tests results across laboratories.


Assuntos
Infecções por Vírus Epstein-Barr , Herpesvirus Humano 4 , Sensibilidade e Especificidade , Centros de Atenção Terciária , Carga Viral , Humanos , Carga Viral/métodos , Infecções por Vírus Epstein-Barr/diagnóstico , Infecções por Vírus Epstein-Barr/virologia , Herpesvirus Humano 4/isolamento & purificação , Herpesvirus Humano 4/genética , Pessoa de Meia-Idade , Feminino , Adulto , Masculino , Idoso , Adulto Jovem , Adolescente , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Transplante de Células-Tronco Hematopoéticas , Criança , Pré-Escolar , DNA Viral/sangue , Kit de Reagentes para Diagnóstico/normas
13.
Virol J ; 21(1): 121, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816844

RESUMO

BACKGROUND: During the pandemic, whole genome sequencing was critical to characterize SARS-CoV-2 for surveillance, clinical and therapeutical purposes. However, low viral loads in specimens often led to suboptimal sequencing, making lineage assignment and phylogenetic analysis difficult. We propose an alternative approach to sequencing these specimens that involves sequencing in triplicate and concatenation of the reads obtained using bioinformatics. This proposal is based on the hypothesis that the uncovered regions in each replicate differ and that concatenation would compensate for these gaps and recover a larger percentage of the sequenced genome. RESULTS: Whole genome sequencing was performed in triplicate on 30 samples with Ct > 32 and the benefit of replicate read concatenation was assessed. After concatenation: i) 28% of samples reached the standard quality coverage threshold (> 90% genome covered > 30x); ii) 39% of samples did not reach the coverage quality thresholds but coverage improved by more than 40%; and iii) SARS-CoV-2 lineage assignment was possible in 68.7% of samples where it had been impaired. CONCLUSIONS: Concatenation of reads from replicate sequencing reactions provides a simple way to access hidden information in the large proportion of SARS-CoV-2-positive specimens eliminated from analysis in standard sequencing schemes. This approach will enhance our potential to rule out involvement in outbreaks, to characterize reinfections and to identify lineages of concern for surveillance or therapeutical purposes.


Assuntos
COVID-19 , Genoma Viral , Filogenia , SARS-CoV-2 , Carga Viral , Sequenciamento Completo do Genoma , SARS-CoV-2/genética , SARS-CoV-2/classificação , SARS-CoV-2/isolamento & purificação , Humanos , COVID-19/virologia , Carga Viral/métodos , Genoma Viral/genética , Sequenciamento Completo do Genoma/métodos , Biologia Computacional/métodos , RNA Viral/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos
14.
Clin Microbiol Infect ; 30(8): 1067-1073, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38735369

RESUMO

OBJECTIVES: Widespread testing and treatment are essential to eliminate hepatitis B virus (HBV) infection as a public health concern. However, in resource-limited countries, access to HBV PCR is limited. In this study, we developed a quantitative HBV PCR assay on open molecular platforms and evaluate its performance in diagnosing clinically significant HBV DNA thresholds as defined by the WHO (2000 IU/mL, 20 000 IU/mL, and 200 000 IU/mL). METHODS: We implemented our HBV PCR test in seven African and Asian countries and France, using either an in-house laboratory method or a European conformity for in vitro diagnostic (CE-IVD) marked version of the PCR (Generic HBV Charge Virale, Biocentric). Results were compared with reference tests (Roche Cobas AmpliPrep/Cobas TaqMan and Abbott RealTime on Abbott m2000). RESULTS: There was a good agreement between the HBV DNA results of 1015 samples tested by the PCR on open polyvalent platforms and the results from reference tests (mean difference (bias ± standard deviation [SD]): -0.3 ± 0.7 log10 IU/mL and -0.2 ± 0.9 log10 IU/mL when compared with Roche and Abbott tests, respectively). Kappa-Cohen agreements between the HBV PCR on open polyvalent platforms and the Roche/Abbott assays appeared almost perfect for HBV DNA levels ranged from >20 000 to 200 000 IU/mL and >200 000 IU/mL, substantial and moderate for HBV DNA levels ranged from 2000 to 20 000 IU/mL when compared with Abbott and Roche, respectively. The assay's performance was consistent across genotypes A, B, C, D, and E. DISCUSSION: This field evaluation showed that our HBV PCR test is a valuable alternative to proprietary PCR systems. PCR assays on open platforms contribute to expanding clinical laboratory solutions for diagnosing individuals who meet the viral load criteria for antiviral therapy (>20 000 IU/mL) and mother-to-child prophylaxis (>200 000 IU/mL).


Assuntos
DNA Viral , Vírus da Hepatite B , Hepatite B , Humanos , Vírus da Hepatite B/genética , Vírus da Hepatite B/isolamento & purificação , DNA Viral/genética , África , Hepatite B/diagnóstico , Hepatite B/virologia , Ásia , Sensibilidade e Especificidade , Técnicas de Diagnóstico Molecular/métodos , Feminino , Carga Viral/métodos , Masculino , Reação em Cadeia da Polimerase/métodos , Adulto , Reação em Cadeia da Polimerase em Tempo Real/métodos , Pessoa de Meia-Idade
15.
Sci Rep ; 14(1): 10923, 2024 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740976

RESUMO

Though pooling samples for SARS-CoV-2 detection has effectively met the need for rapid diagnostic and screening tests, many factors can influence the sensitivity of a pooled test. In this study, we conducted a simulation experiment to evaluate modes of pooling specimens and aimed at formulating an optimal pooling strategy. We focussed on the type of swab, their solvent adsorption ability, pool size, pooling volume, and different factors affecting the quality of preserving RNA by different virus solutions. Both quantitative PCR and digital PCR were used to evaluate the sampling performance. In addition, we determined the detection limit by sampling which is simulated from the virus of different titers and evaluated the effect of sample-storage conditions by determining the viral load after storage. We found that flocked swabs were better than fibre swabs. The RNA-preserving ability of the non-inactivating virus solution was slightly better than that of the inactivating virus solution. The optimal pooling strategy was a pool size of 10 samples in a total volume of 9 mL. Storing the collected samples at 4 °C or 25 °C for up to 48 h had little effect on the detection sensitivity. Further, we observed that our optimal pooling strategy performed equally well as the single-tube test did. In clinical applications, we recommend adopting this pooling strategy for low-risk populations to improve screening efficiency and shape future strategies for detecting and managing other respiratory pathogens, thus contributing to preparedness for future public health challenges.


Assuntos
COVID-19 , RNA Viral , SARS-CoV-2 , Manejo de Espécimes , Humanos , COVID-19/diagnóstico , COVID-19/virologia , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Manejo de Espécimes/métodos , RNA Viral/genética , Teste de Ácido Nucleico para COVID-19/métodos , Carga Viral/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade , Teste para COVID-19/métodos
16.
Viruses ; 16(5)2024 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-38793553

RESUMO

DNA assays for viral load (VL) monitoring are key tools in the management of immunocompromised patients with cytomegalovirus (CMV) or Epstein-Barr virus (EBV) infection. In this study, the analytical and clinical performances of the NeuMoDx™ CMV and EBV Quant Assays were compared with artus CMV and EBV QS-RGQ Kits in a primary hospital testing laboratory. Patient plasma samples previously tested using artus kits were randomly selected for testing by NeuMoDx assays. The NeuMoDx CMV Quant Assay and artus CMV QS-RGQ Kit limits of detection (LoDs) are 20.0 IU/mL and 69.7 IU/mL, respectively; 33/75 (44.0%) samples had CMV DNA levels above the LoD of both assays. The Pearson correlation coefficient was 0.9503; 20 samples (60.6%) had lower NeuMoDx CMV quantification values versus the artus kit. The LoD of the NeuMoDx EBV Quant Assay and artus EBV QS-RGQ Kit are 200 IU/mL and 22.29 IU/mL, respectively; 16/75 (21.3%) samples had EBV DNA levels above the LoD of both assays. The Pearson correlation coefficient was 0.8990. EBV quantification values with the NeuMoDx assay were higher versus the artus kit in 15 samples (93.8%). In conclusion, NeuMoDx CMV and EBV Quant Assays are sensitive and accurate tools for CMV and EBV DNA VL quantification.


Assuntos
Citomegalovirus , Herpesvirus Humano 4 , Carga Viral , Virologia , Herpesvirus Humano 4/fisiologia , Citomegalovirus/fisiologia , Carga Viral/instrumentação , Carga Viral/métodos , Virologia/instrumentação , Virologia/métodos , Limite de Detecção , Infecções por Citomegalovirus/sangue , Infecções por Citomegalovirus/virologia , Infecções por Vírus Epstein-Barr/sangue , Infecções por Vírus Epstein-Barr/virologia , Técnicas de Laboratório Clínico/instrumentação , Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/normas , Humanos
17.
Microbiol Spectr ; 12(6): e0007324, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38683014

RESUMO

The COVID-19 pandemic has highlighted the critical need for accurate and efficient diagnostic tools for detecting severe acute respiratory coronavirus 2 (SARS-CoV-2) infections. This study presents a comparison of two diagnostic tests: RT-PCR and antigen detection rapid diagnostic tests (Ag-RDTs). This study focused on their performance, variant specificity, and their clinical implications. A simultaneous testing of 268 samples was carried out for SARS-CoV-2 using RT-PCR and Ag-RDTs [flourescence immunoassay (FIA) and lateral flow immunoassay (LFIA)]. Viral load was quantified, and variant identification was performed using a PCR-based assay. The prevalence was found to be 30.2% using reverse transcription PCR (RT-PCR), 26.5% using FIA, and 25% using LFIA. When comparing the FIA and LFIA, the overall diagnostic performance was found to be 80.25% vs 76.54%, 96.79% vs 97.33%, 91.55% vs 90.51%, and 91.88% vs 92.56% for sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), respectively. Both Ag-RDTs showed a strong agreement with RT-PCR (κ = 0.78-0.80). The overall accuracies of the FIA and LFIA were 92.41% and 92.13%, respectively. The FIA showed higher sensitivity (73.68%) and PPV (92.08%) than the LFIA (65.79% and 90.56%, respectively) in asymptomatic patients. At low Ct values (<25), both Ag-RDTs had 100% sensitivity, but the sensitivity reduced to 31.82% for FIA and 27.27% for LFIA at Ct values > 30. The diagnostic sensitivity of FIA compared to LFIA for detecting the Alpha variant was 78.85% vs. 69.23% and 72.22% vs. 83.33% for the Delta variant. Both Ag-RDTs had 100% sensitivity for detecting Omicron. Both Ag-RDTs performed well in patients with high viral loads and Omicron variant infections compared to those infected with Alpha and Delta variants. This study confirms the comparable performance of RT-PCR and Ag-RDTs, specifically FIA and LFIA, for SARS-CoV-2 detection. The FIA showed higher sensitivity and PPV in asymptomatic cases, while both Ag-RDTs exhibited strong agreement with RT-PCR results. Notably, Ag-RDTs, particularly FIA, proved effective in detecting the Omicron variant and cases with high viral loads, highlighting their potential clinical utility in managing the COVID-19 pandemic.IMPORTANCEThis study is of utmost importance in providing effective responses to manage the COVID-19 pandemic. It rigorously compares the diagnostic accuracy, variant specificity, and practical considerations of reverse transcription PCR (RT-PCR) and antigen detection rapid diagnostic tests (Ag-RDTs) for severe acute respiratory coronavirus 2 (SARS-CoV-2), answering critical questions. The results of this study will help healthcare professionals choose the appropriate testing methods, allocate resources effectively, and enhance public health strategies. Given the evolution of the virus, understanding the performance of these diagnostic tools is crucial to adapting to emerging variants. Additionally, the study provides insights into logistical challenges and accessibility issues, which will contribute to refining testing workflows, particularly in resource-limited settings. Ultimately, the study's impact extends to global healthcare, providing valuable information for policymakers, clinicians, and public health officials as they work together for mitigating the impact of the pandemic.


Assuntos
Antígenos Virais , COVID-19 , SARS-CoV-2 , Sensibilidade e Especificidade , Carga Viral , Humanos , COVID-19/diagnóstico , COVID-19/virologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/imunologia , Antígenos Virais/análise , Carga Viral/métodos , Adulto , Pessoa de Meia-Idade , Feminino , Masculino , Imunoensaio/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Idoso , Teste Sorológico para COVID-19/métodos , Adulto Jovem , Adolescente , Teste de Ácido Nucleico para COVID-19/métodos , Testes Diagnósticos de Rotina/métodos , Criança , Teste para COVID-19/métodos , Testes de Diagnóstico Rápido
18.
Sci Rep ; 14(1): 8700, 2024 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622191

RESUMO

HIV infection has been a global public health threat and overall reported ~ 40 million deaths. Acquired immunodeficiency syndrome (AIDS) is attributed to the retroviruses (HIV-1/2), disseminated through various body fluids. The temporal progression of AIDS is in context to the rate of HIV-1 infection, which is twice as protracted in HIV-2 transmission. Q-PCR is the only available method that requires a well-developed lab infrastructure and trained personnel. Micro-PCR, a portable Q-PCR device, was developed by Bigtec Labs, Bangalore, India. It is simple, accurate, fast, and operationalised in remote places where diagnostic services are inaccessible in developing countries. This novel micro-PCR determines HIV-1 and HIV-2 viral load using a TruePrep™ extractor device for RNA isolation. Five ml blood samples were collected at the blood collection centre at AIIMS, New Delhi, India. Samples were screened for serology, and a comparison of HIV-1/2 RNA was done between qPCR and micro-PCR in the samples. The micro-PCR assay of HIV-RNA has compared well with those from real-time PCR (r = 0.99, i < 0.002). Micro-PCR has good inter and intra-assay reproducibility over a wide dynamic range (1.0 × 102-1.0 × 108 IU/ml). The linear dynamic range was 102-108 IU/ml. The clinical and analytical specificity of the assay was comparable, i.e., 100%. Intra-assay and inter-assay coefficients of variation ranged from 1.17% to 3.15% and from 0.02% to 0.46%, respectively. Moreover, due to the robust, simple, and empirical method, the Probit analysis has also been done for qPCR LODs to avoid uncertainties in target recoveries. The micro-PCR is reliable, accurate, and reproducible for early detection of HIV-1 and HIV-2 viral loads simultaneously. Thus, it can easily be used in the field and in remote places where quantification of both HIV-1/2 is not reachable.


Assuntos
Síndrome da Imunodeficiência Adquirida , Infecções por HIV , Soropositividade para HIV , HIV-1 , Humanos , HIV-1/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , RNA Viral/análise , Índia , Reação em Cadeia da Polimerase em Tempo Real/métodos , HIV-2/genética , Carga Viral/métodos
19.
J Virol Methods ; 327: 114937, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38614281

RESUMO

Quantification of hepatitis C virus (HCV)-RNA in serum or plasma samples is an essential parameter in HCV diagnostics. Here, the NeuMoDx™Molecular System (Qiagen) was tested for the most common HCV genotypes and compared to the cobas c6800 system (Roche). HCV-RNA from 131 plasma/serum samples from chronically infected patients was determined in parallel on the NeuMoDx and c6800 systems. Linearity was analysed using the four most common HCV genotypes (1-4) in our cohort. The coefficient of variation (CV) within (intra-assay) and between (inter-assay) runs was calculated based on HCV-RNA concentration. Quantitative HCV-RNA results were highly correlated on both test systems (R2 = 0.7947; y = 0.94 x + 0.37). On average, the NeuMoDx and c6800 HCV RNA levels showed a mean difference of only 0.05 log10 IU/mL but with a broad distribution (±1.2 2 x SD). The NeuMoDx demonstrated very good linearity across all HCV genotypes tested at concentrations between 1.7 and 6.2 log10 IU/mL (R2 range: 0.9257-0.9991) with the highest mean coefficient of determination for genotype 1 (R2 = 0.9909). The mean intra- and inter-assay CV for both serum and plasma samples was <5 %. The NeuMoDx HCV-RNA Assay demonstrates high subtype-independent comparability, linearity, and reproducibility for the quantification of HCV-RNA in serum and plasma samples from chronically infected patients.


Assuntos
Genótipo , Hepacivirus , RNA Viral , Carga Viral , Humanos , Hepacivirus/genética , Hepacivirus/isolamento & purificação , RNA Viral/sangue , RNA Viral/genética , Carga Viral/métodos , Reprodutibilidade dos Testes , Hepatite C Crônica/virologia , Hepatite C Crônica/diagnóstico , Hepatite C Crônica/sangue , Sensibilidade e Especificidade , Hepatite C/diagnóstico , Hepatite C/virologia , Hepatite C/sangue , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Kit de Reagentes para Diagnóstico/normas
20.
J Clin Microbiol ; 62(4): e0135423, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38526061

RESUMO

BK virus (BKV) infection or reactivation in immunocompromised individuals can lead to adverse health consequences including BKV-associated nephropathy (BKVAN) in kidney transplant patients and BKV-associated hemorrhagic cystitis (BKV-HC) in allogeneic hematopoietic stem cell transplant recipients. Monitoring BKV viral load plays an important role in post-transplant patient care. This study evaluates the performance of the Alinity m BKV Investigational Use Only (IUO) assay. The linearity of the Alinity m BKV IUO assay had a correlation coefficient of 1.000 and precision of SD ≤ 0.25 Log IU/mL for all panel members tested (2.0-7.3 Log IU/mL). Detection rate at 50 IU/mL was 100%. Clinical plasma specimens tested comparing Alinity m BKV IUO to ELITech MGB Alert BKV lab-developed test (LDT) on the Abbott m2000 platform using specimen extraction protocols for DNA or total nucleic acid (TNA) resulted in coefficient of correlation of 0.900 and 0.963, respectively, and mean bias of 0.03 and -0.54 Log IU/mL, respectively. Alinity m BKV IUO compared with Altona RealStar BKV and Roche cobas BKV assays demonstrated coefficient of correlation of 0.941 and 0.980, respectively, and mean bias of -0.47 and -0.31 Log IU/mL, respectively. Urine specimens tested on Alintiy m BKV IUO and ELITech BKV LDT using TNA specimen extraction had a coefficient of correlation of 0.917 and mean bias of 0.29 Log IU/mL. The Alinity m BKV IUO assay was performed with high precision across the dynamic range and correlated well with other available BKV assays. IMPORTANCE: BK virus (BKV) in transplant patients can lead to adverse health consequences. Viral load monitoring is important in post-transplant patient care. This study evaluates the Alinity m BKV assay with currently available assays.


Assuntos
Vírus BK , Transplante de Rim , Ácidos Nucleicos , Infecções por Polyomavirus , Infecções Tumorais por Vírus , Humanos , Vírus BK/genética , Transplante de Rim/efeitos adversos , Infecções por Polyomavirus/diagnóstico , Carga Viral/métodos , Infecções Tumorais por Vírus/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...