Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.110
Filtrar
1.
J Refract Surg ; 40(6): e354-e361, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848053

RESUMO

PURPOSE: To assess the predictive accuracy of new-generation online intraocular lens (IOL) power formulas in eyes with previous myopic laser refractive surgery (LRS) and to evaluate the influence of corneal asphericity on the predictive accuracy. METHODS: The authors retrospectively evaluated 52 patients (78 eyes) with a history of laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) who subsequently underwent cataract surgery. Refractive prediction errors were calculated for 12 no-history new online formulas: 8 formulas with post-LRS versions (Barrett True-K, EVO 2.0, Hoffer QST, and Pearl DGS) using keratometry and posterior/total keratometry measured by IOLMaster 700 and 4 formulas without post-LRS versions (Cooke K6 and Kane) using keratometry and total keratometry. The refractive prediction error, mean absolute error (MAE), and percentages of eyes with prediction errors of ±0.25, ±0.50, ±0.75, ±1.00, and ±1.50 diopters (D) were compared. RESULTS: The MAEs of the 12 formulas were significantly different (F = 83.66, P < .001). The MAEs ranged from 0.62 to 0.94 D and from 1.07 to 1.84 D in the formulas with and without post-LRS versions, respectively. The EVO formula produced the lowest MAE (0.60) and MedAE (0.47), followed by the Barrett True-K (0.69 and 0.50, respectively). Each percentage of eyes with refractive prediction error was also significantly different among the 12 formulas (P < .001). CONCLUSIONS: The EVO and Barrett True-K formulas demonstrate comparable performance to the other existing formulas in eyes with a history of myopic LASIK/PRK. Surgeons should use these formulas with post-LRS versions and input keratometric values whenever possible. [J Refract Surg. 2024;40(6):e354-e361.].


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Implante de Lente Intraocular , Lentes Intraoculares , Miopia , Óptica e Fotônica , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Feminino , Masculino , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Ceratectomia Fotorrefrativa/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Adulto , Acuidade Visual/fisiologia , Lasers de Excimer/uso terapêutico , Córnea/cirurgia , Córnea/fisiopatologia , Reprodutibilidade dos Testes , Biometria/métodos , Facoemulsificação , Idoso
2.
J Refract Surg ; 40(6): e371-e380, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848054

RESUMO

PURPOSE: To report on the prospective evaluation of photorefractive keratectomy (PRK) in experienced ametropic naval aviators that led to the approval of refractive surgery for military pilots. METHODS: This was the first study evaluating refractive surgery in naval aviators. Return to flight status after PRK and clinical outcomes and subjective and objective flight performance were evaluated. RESULTS: A total of 785 U.S. naval aviators were enrolled in the study. Average preoperative refraction was -2.92 ± 1.73 diopters (D) (range: +5.25 to -9.13 D). By 6 months, 85.9% of eyes were within ±0.50 D and 96.4% were within ±1.00 D of emmetropia. 94.4% of eyes achieved 20/20 or better, 74.3% had 20/16 or better, and 45.2% had 20/12.5 or better uncorrected distance visual acuity (UDVA) at 6 months. A total of 78.5% of aviators met return-to-flight criteria by 4 weeks, 83.3% by 8 weeks, and 90.8% by 12 weeks following PRK. All aviators eventually returned to full flight status. Cumulative flight experience included logging more than 48,000 flight hours and 19,500 landings in the 6 months following PRK. Psychometric questionnaire results showed that 78% reported improved ability to detect other aircraft and 92% reported improved ability to land on an aircraft carrier (82% significantly improved) compared to wearing corrective lenses. No one felt their vision was worse in these dynamic environments. All aviators indicated they would undergo the procedure again and would recommend it to a fellow aviator. CONCLUSIONS: This prospective study in U.S. naval aviators determined PRK to be safe and effective in a unique patient population operating in a visually demanding and hazardous environment. The program continues to be enthusiastically supported by aviators and PRK is now allowed in all branches of the military and for National Aeronautics and Space Administration astronauts. [J Refract Surg. 2024;40(6):e371-e380.].


Assuntos
Lasers de Excimer , Militares , Miopia , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Ceratectomia Fotorrefrativa/métodos , Humanos , Estudos Prospectivos , Acuidade Visual/fisiologia , Adulto , Masculino , Estados Unidos , Feminino , Miopia/cirurgia , Miopia/fisiopatologia , Lasers de Excimer/uso terapêutico , Refração Ocular/fisiologia , Adulto Jovem , Pessoa de Meia-Idade , Medicina Aeroespacial , Resultado do Tratamento
3.
Int Ophthalmol ; 44(1): 252, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38907885

RESUMO

PURPOSE: To evaluate the refractive results of Transepithelial Photorefractive Keratectomy (t-PRK) with the Technolas Teneo2 Excimer laser platform. METHODS: In this retrospective comparative interventional case series, a total of 199 patients with myopia ranging from - 1 to - 7 diopters were enrolled and separated into three groups based on their target refraction of zero (group 1), - 0.25 (group 2), and - 0.5 diopters (group 3), respectively. The main outcome measure was post-operative cycloplegic refraction. Trans-PRK was performed using the Technolas Teneo2 Excimer laser. To prevent any remaining epithelium during stromal ablation, we adopted the thickest epithelial point in the 7 mm central map as the reference for Phototherapeutic keratectomy (PTK) depth. Patients were examined three and twelve months after the procedure, and the results were analyzed. RESULTS: At the 12-month follow-up, uncorrected distance visual acuity was 20/20 in all patients. However, there was a significant difference in cycloplegic spherical equivalent refraction between the three groups. The 12-month post-operative spherical equivalent refraction was 0.90 ± 0.33 D, 0.79 ± 0.26 D, and 0.60 ± 0.19 D in groups 1, 2, and 3, respectively (P < 0.001; Kruskal-Wallis test). The rates of spherical equivalent refraction of more than 0.75 D were 58.3%, 39.1%, and 9.1% in the 0 D, - 0.25 D, and -0.50 D groups, respectively (P < 0.001; Chi-squared test). CONCLUSIONS: The t-PRK with Technolas Teneo2 Excimer laser and epithelial thickness map adjustment of PTK induce a significant amount of residual hyperopia (> 0.75 D) in a large proportion of eyes with a target refraction of 0 or - 0.25, which is significantly reduced by using a target refraction of - 0.5.


Assuntos
Astigmatismo , Epitélio Corneano , Lasers de Excimer , Miopia , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Ceratectomia Fotorrefrativa/métodos , Estudos Retrospectivos , Masculino , Feminino , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico , Adulto , Miopia/cirurgia , Miopia/fisiopatologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Epitélio Corneano/patologia , Epitélio Corneano/cirurgia , Adulto Jovem , Seguimentos , Resultado do Tratamento , Topografia da Córnea
4.
Int Ophthalmol ; 44(1): 273, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38916805

RESUMO

PURPOSE: To evaluate the intraoperative central corneal epithelial thickness (ET) as measured by optical coherence pachymetry (OCP) in myopic eyes undergoing alcohol-assisted photorefractive keratectomy (PRK). METHODS: A retrospective review of patients who underwent alcohol-assisted PRK was performed. Data were abstracted on age, gender, contact lens (CL) wear, preoperative refractive errors, keratometry, topographic and ultrasonic pachymetry, and intraoperative OCP measurements before and after epithelium removal. The central ET was calculated by subtracting OCP measurement after epithelium removal from the OCP measurement prior to epithelium removal. RESULTS: The study comprised of 162 consecutive eyes from 81 patients. Mean age was 26.73 ± 6.47 years, 50.6% were males. CL was used in 92 eyes (56.8%). The mean sphere and spherical equivalent were -3.60 ± 1.84 D and -3.26 ± 1.85D, respectively. The mean intraoperative ET was 58.22 ± 17.53 µm (range, 15-121µm). Fifty-five percent of the eyes had an ET measurement above or below the range of 40-60µm. ET was significantly higher in the second operated eye compared to the first operated eye (p = 0.006), and an association was found to CL-wear (p = 0.03). There was no significant difference in thickness between genders (p = 0.62), and no correlation to patient age (p = 0.45, rp = 0.06), refractive errors (p > 0.30,rp=-0.07-0.08), nor keratometry(p > 0.80, rp=-0.01- (-0.02)). CONCLUSION: The intraoperative assessment of ET in alcohol-assisted PRK showed a high variability of the central corneal epithelium, with a significant difference between the first and second operated eyes. This difference may have implications when the epithelium is not included in the surgical planning in surface ablation.


Assuntos
Epitélio Corneano , Miopia , Ceratectomia Fotorrefrativa , Humanos , Ceratectomia Fotorrefrativa/métodos , Masculino , Feminino , Adulto , Estudos Retrospectivos , Epitélio Corneano/patologia , Epitélio Corneano/diagnóstico por imagem , Miopia/cirurgia , Miopia/fisiopatologia , Adulto Jovem , Paquimetria Corneana , Lasers de Excimer/uso terapêutico , Período Intraoperatório , Tomografia de Coerência Óptica/métodos , Topografia da Córnea/métodos , Adolescente , Refração Ocular/fisiologia , Acuidade Visual
5.
Curr Opin Ophthalmol ; 35(4): 284-291, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38700946

RESUMO

PURPOSE OF REVIEW: Higher degrees of myopia are currently being treated with refractive surgery. However, there is limited characterization and outcomes data for this cohort. This article aims to review the literature on highly myopic patients who had refractive surgery and present a retrospective analysis of 149 patients (270 eyes) with high to extreme myopia (≤-5.0D SE) who underwent refractive surgery [laser-assisted subepithelial keratomileusis (LASIK), photorefractive keratectomy (PRK), or implantable collamer lense (ICL)] at a single practice. RECENT FINDINGS: There is substantial literature on the efficacy of LASIK, PRK, and phakic intraocular lenses for refractive error correction, but a dearth of studies on patients with high to extreme myopia undergoing different types of refractive surgery. Our study reveals that this cohort of patients has excellent outcomes with minimal complications. SUMMARY: Our study reveals that the average preoperative myopia was highest in ICL patients (-10.03D), followed by PRK (-7.21D), and LASIK (-7.04D) patients. Not surprisingly, eyes with high myopia and thin corneas were offered and elected ICLs for their procedure. Highly myopic patients achieved outcomes consistent with data reported in the literature- average postoperative uncorrected visual acuity was 20/20 for LASIK and ICL eyes and 20/25 for PRK eyes.


Assuntos
Ceratectomia Fotorrefrativa , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Resultado do Tratamento , Ceratectomia Fotorrefrativa/métodos , Implante de Lente Intraocular/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Refração Ocular/fisiologia , Estudos Retrospectivos , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Miopia/cirurgia , Miopia/fisiopatologia , Lentes Intraoculares Fácicas , Adulto , Masculino , Feminino
6.
Vestn Oftalmol ; 140(2. Vyp. 2): 51-59, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739131

RESUMO

PURPOSE: The study investigates the influence of changes in keratometric parameters after refractive surgery on the results of Maklakov tonometry. MATERIAL AND METHODS: The study examined a total of 61 people (121 eyes). The patients were divided into a control group with no history of surgery (16 people, 31 eyes), a LASIK group (13 people, 26 eyes), a femtosecond-assisted LASIK (FS-LASIK) group (16 people, 32 eyes), and a photorefractive keratectomy (PRK) group (16 people, 32 eyes). The patients underwent standard examination, keratometry (Km), Maklakov tonometry with a 10 g weight, and elastotonometry with 5, 7.5, and 15 g weights. RESULTS: In the LASIK group, the indentation diameter with 5 and 7.5 g weights correlated with Km in the central and near-paracentral zone (r=0.3-0.5). Tonometry with a 10 g weight did not correlate with anything. Tonometry with a 15 g weight inversely correlated with Km in the paracentral points (4 mm) of the strong meridian (r= -0.5 ... -0.7). In the FS-LASIK group, a significant inverse correlation with Km was observed only for the indentation diameter with a 10 g weight in the paracentral (3-4 mm) zone (r= -0.4 ... -0.5). In the PRK group, weak (r<0.4) correlations were found between Km and the indentation diameter of the 7.5 and 10 g weights for the central zone (1-2 mm). No significant correlations were found for 5 and 15 g weights.In the control group, there were practically no correlations for 5 and 7.5 g weights. The indentation diameter of the 10 g weight evenly correlated with Km at all points (r= -0.38 ... -0.60), the indentation of the 15 g weight correlated mainly with the curvature of the horizontal meridian (r= -0.37 ... -0.49). CONCLUSION: Tonometry readings with the 10 g weight are the most dependent on Km in different groups, and the readings with the 5 g weight are the least dependent. LASIK is characterized by the largest scatter of dependencies for weights of different masses, FS-LASIK - by the smallest. Tonometry readings with the 5 g weight correlated with Km only in the LASIK group, and this was the only direct correlation. Considering the inverse nature of most correlations, higher Km may be associated with an overestimation of tonometry results, and lower Km - with its underestimation.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Ceratectomia Fotorrefrativa , Tonometria Ocular , Humanos , Adulto , Masculino , Feminino , Tonometria Ocular/métodos , Ceratectomia Fotorrefrativa/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Córnea/cirurgia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia , Miopia/cirurgia , Miopia/fisiopatologia , Miopia/diagnóstico , Pressão Intraocular/fisiologia
7.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717086

RESUMO

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Assuntos
Córnea , Elasticidade , Pressão Intraocular , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Humanos , Córnea/fisiopatologia , Córnea/cirurgia , Adulto , Feminino , Masculino , Fenômenos Biomecânicos , Lasers de Excimer/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Adulto Jovem , Elasticidade/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Pressão Intraocular/fisiologia , Ceratectomia Fotorrefrativa/métodos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Estudos Prospectivos , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
8.
Aerosp Med Hum Perform ; 95(5): 278-281, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38715272

RESUMO

BACKGROUND: This article documents the stability of photorefractive keratectomy (PRK) and laser-assisted in situ keratomileusis (LASIK) in two astronauts during 6-mo missions to the International Space Station.CASE REPORTS: Ocular examinations including visual acuity, cycloplegic refraction, slit lamp examination, corneal topography, central corneal thickness, optical biometry (axial length/keratometry), applanation tonometry, and dilated fundus examination were performed on each astronaut before and after their missions, and in-flight visual acuity testing was done on flight day 30, 90, and R-30 (30 d before return). They were also questioned regarding visual changes during flight.DISCUSSION: We documented stable vision in both PRK and LASIK astronauts during liftoff, entry into microgravity, 6 mo on the International Space Station, descent, and landing. Our results suggest that both PRK and LASIK are stable and well tolerated during long-duration spaceflight.Gibson CR, Mader TH, Lipsky W, Schallhorn SC, Tarver WJ, Suresh R, Hauge TN, Brunstetter TJ. Photorefractive keratectomy and laser-assisted in situ keratomileusis on 6-month space missions. Aerosp Med Hum Perform. 2024; 95(5):278-281.


Assuntos
Astronautas , Ceratomileuse Assistida por Excimer Laser In Situ , Ceratectomia Fotorrefrativa , Voo Espacial , Acuidade Visual , Humanos , Medicina Aeroespacial , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Miopia/cirurgia , Miopia/fisiopatologia , Ceratectomia Fotorrefrativa/métodos , Acuidade Visual/fisiologia
9.
Transl Vis Sci Technol ; 13(5): 11, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38748408

RESUMO

Purpose: Computational models can help clinicians plan surgeries by accounting for factors such as mechanical imbalances or testing different surgical techniques beforehand. Different levels of modeling complexity are found in the literature, and it is still not clear what aspects should be included to obtain accurate results in finite-element (FE) corneal models. This work presents a methodology to narrow down minimal requirements of modeling features to report clinical data for a refractive intervention such as PRK. Methods: A pipeline to create FE models of a refractive surgery is presented: It tests different geometries, boundary conditions, loading, and mesh size on the optomechanical simulation output. The mechanical model for the corneal tissue accounts for the collagen fiber distribution in human corneas. Both mechanical and optical outcome are analyzed for the different models. Finally, the methodology is applied to five patient-specific models to ensure accuracy. Results: To simulate the postsurgical corneal optomechanics, our results suggest that the most precise outcome is obtained with patient-specific models with a 100 µm mesh size, sliding boundary condition at the limbus, and intraocular pressure enforced as a distributed load. Conclusions: A methodology for laser surgery simulation has been developed that is able to reproduce the optical target of the laser intervention while also analyzing the mechanical outcome. Translational Relevance: The lack of standardization in modeling refractive interventions leads to different simulation strategies, making difficult to compare them against other publications. This work establishes the standardization guidelines to be followed when performing optomechanical simulations of refractive interventions.


Assuntos
Simulação por Computador , Córnea , Análise de Elementos Finitos , Ceratectomia Fotorrefrativa , Humanos , Córnea/cirurgia , Córnea/fisiologia , Ceratectomia Fotorrefrativa/métodos , Simulação por Computador/normas , Lasers de Excimer/uso terapêutico , Modelos Biológicos
10.
BMC Ophthalmol ; 24(1): 145, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38561680

RESUMO

BACKGROUND: The purpose of this study was to analyze myopic regression after corneal refractive surgery (CRS) in civilian pilots and to explore the factors that may cause long-term myopic regression. METHODS: We included civilian pilots who had undergone CRS to correct their myopia and who had at least 5 years of follow-up. We collected retrospective data and completed eye examinations and a questionnaire to assess their eye habits. RESULTS: A total of 236 eyes were evaluated in this study. 211 eyes had Intrastromal ablations (167 eyes had laser in situ keratomileusis, LASIK, 44 eyes had small incision lenticule extraction, SMILE) and 25 eyes had subepithelial ablations (15 eyes had laser epithelial keratomileusis, LASEK and 10 eyes had photorefractive keratectomy, PRK). The mean preoperative spherical equivalent (SE) was - 2.92 ± 1.11 D (range from - 1.00 to -5.00 D). A total of 56 eyes (23.6%) suffered from myopic regression after CRS. Comparisons of individual and eye characteristics between the regression and non-regression groups revealed statistically significant differences in age, cumulative flight time, postoperative SE (at 6 months and current), uncorrected visual acuity (UCVA), accommodative amplitude (AA), positive relative accommodation (PRA), postoperative period, types of CRS and eye habits. Generalized propensity score weighting (GPSW) was used to balance the distribution of covariates among different age levels, types of CRS, cumulative flying time, postoperative period and continuous near-work time. The results of GPS weighted logistic regression demonstrated that the associations between age and myopic regression, types of CRS and myopic regression, continuous near-work time and myopic regression were significant. Cumulative flying time and myopic regression, postoperative period and myopic regression were no significant. Specifically, the odds ratio (OR) for age was 1.151 (P = 0.022), and the OR for type of CRS was 2.769 (P < 0.001). The OR for continuous near-work time was 0.635 with a P value of 0.038. CONCLUSIONS: This is the first report to analyze myopic regression after CRS in civilian pilots. Our study found that for each year increase in age, the risk of civilian pilots experiencing myopic regression was increased. Intrastromal ablations had a lower risk of long-term myopia regression than subepithelial ablations. There is a higher risk of myopic progression with continuous near-work time > 45 min and poor accommodative function may be related factors in this specific population.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Humanos , Lactente , Estudos Retrospectivos , Córnea/cirurgia , Ceratectomia Fotorrefrativa/métodos , Acuidade Visual , Refração Ocular , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Resultado do Tratamento
11.
J Cataract Refract Surg ; 50(7): 733-738, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38446490

RESUMO

PURPOSE: To explore visual outcomes in patients with extreme myopia receiving an implantable collamer lens (ICL) at -18.00 diopters (D), with central port, followed by bioptics by laser vision correction (laser in situ keratomileusis [LASIK] or photorefractive keratectomy [PRK]) to address residual myopia or myopic astigmatism. SETTING: Clínica Baviera (Aier Eye Hospital Group), Bilbao, Spain. DESIGN: Retrospective analysis of cases. METHODS: The study assessed uncorrected distance visual acuity, corrected distance visual acuity (CDVA), predictability, safety, efficacy, and patient satisfaction after implantation of the ICL and bioptics. The model implanted was V4c and EVO, with a correction of -18.00 D. Bioptics were performed at least 3 months after implantation, and patients were followed up for at least 3 months after LASIK or PRK. RESULTS: The analysis included 125 eyes from 90 patients. Of these, 51.2% underwent LASIK and 48.8% PRK. Mean time from implantation to bioptics was 5.9 ± 9.4 months. Patients were followed up for a mean of 40.2 ± 37.9 months after bioptics. Median manifest refractive spherical equivalent was -2.89 D before bioptics and -0.49 D after. Median CDVA was 0.18 logMAR before bioptics and 0.17 after. The mean safety and efficacy indices were 2.22 ± 1.88 and 2.06 ± 1.85, respectively. CONCLUSIONS: Visual outcomes and safety indices after ICL implantation and subsequent LASIK or PRK in patients with extreme myopia are excellent.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Implante de Lente Intraocular , Lentes Intraoculares Fácicas , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Estudos Retrospectivos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratectomia Fotorrefrativa/métodos , Masculino , Feminino , Adulto , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico , Adulto Jovem , Satisfação do Paciente , Miopia/cirurgia , Miopia/fisiopatologia , Pessoa de Meia-Idade , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Resultado do Tratamento
12.
Medicine (Baltimore) ; 103(9): e37340, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38428861

RESUMO

To compare changes in the spherical component, regular astigmatism, and irregular astigmatism of the anterior surface of the cornea after small-incision lenticule extraction (SMILE) and transepithelial photorefractive keratectomy (TransPRK). Fifty-six patients underwent SMILE in 56 eyes, and 68 patients underwet TransPRK in 68 eyes. The right eye was chosen to enter the group. Six months after the procedure, Scheimpflug images were acquired, and Fourier analysis of the anterior surface of patients' corneas was performed using the Pentacam built-in software. Fourier parameters encompass various measurements such as the steepest radius of the curvature and average eccentricity of the spherical components (SphRmin and SphEcc), maximum decentration (MaxDec), central and peripheral regular astigmatism (regular astigmatism at the center [AstC] and regular astigmatism at the periphery [AstP]), and irregularity (Irr). At 6 months postoperatively, SphEcc decreased significantly (P < .001), MaxDec increased significantly (P < .001), and Irr increased insignificantly (P = .254) in the SMILE group. SphEcc decreased significantly (P < .001) and MaxDec and Irr increased significantly (P < .001) in the TransPRK group. TransPRK caused greater changes in SphEcc, MaxDec, and Irr on the anterior corneal surface than SMILE (P < .05). The amount of MaxDec-induced changes in SMILE and TransPRK was significantly correlated with the amount of higher-order aberrations and spherical aberration changes (P < .05). SMILE and TransPRK increase overall irregular astigmatism on the anterior surface of the cornea, more so with TransPRK, where changes in decentration are associated with with increased higher-order aberrations.


Assuntos
Astigmatismo , Doenças da Córnea , Miopia , Ceratectomia Fotorrefrativa , Humanos , Ceratectomia Fotorrefrativa/efeitos adversos , Ceratectomia Fotorrefrativa/métodos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Análise de Fourier , Acuidade Visual , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Córnea/cirurgia , Doenças da Córnea/cirurgia
13.
J Cataract Refract Surg ; 50(7): 767-776, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38353281

RESUMO

Laser vision correction for residual refractive errors in patients with previous radial keratotomy (RK) presents a challenging task. Different techniques have been used with varying outcomes. This study aimed to systematically review published articles on refractive surgeries in post-RK patients by conducting a search on PubMed, Scopus, and Web of Science. The final analysis included 35 studies that described a total of 888 eyes. Our systematic review and meta-analysis demonstrated a significant improvement in uncorrected distance visual acuity (UDVA) for photorefractive keratectomy (PRK), topography-guided PRK, wavefront-guided PRK, and femtosecond laser-assisted in situ keratomileusis (LASIK) while mechanical microkeratome LASIK did not yield such significant improvements. Moreover, our results suggest that post-RK patients with hyperopia had a significant improvement in UDVA, whereas no such improvement was observed in patients with myopia.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Ceratotomia Radial , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratectomia Fotorrefrativa/métodos , Lasers de Excimer/uso terapêutico , Erros de Refração/fisiopatologia , Miopia/cirurgia , Miopia/fisiopatologia , Hiperopia/cirurgia , Hiperopia/fisiopatologia
14.
Int Ophthalmol ; 44(1): 17, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38321320

RESUMO

OBJECTIVE: To raise awareness of conditions that can tomographically mimic corneal ectasia and describe the actions required to avoid misdiagnosis. METHODS: We report a retrospective case series of seven patients presenting at two tertiary care centers in Israel with a presumed diagnosis of keratoconus or post-refractive ectasia. Upon further examination, the ectasia diagnosis was reconsidered and eventually ruled out. RESULTS: Included were ten eyes of seven patients. Cases included bilateral diffuse Salzmann's nodular degeneration, ophthalmoplegia with strabismus which precluded proper fixation during the acquisition of tomography images, two cases of incorrect Pentacam parameter settings, a patient with a history of hyperopic laser-assisted in situ keratomileusis (LASIK) treatment in one eye and myopic LASIK in the fellow eye, a case of old post-photorefractive keratectomy (PRK) stromal haze, and a patient with posterior polymorphous corneal dystrophy. CONCLUSIONS: Tomography patterns mimicking corneal ectasia can appear in patients without ectatic pathology. The comprehensive ophthalmologist should be aware of such cases as they may substantially alter the treatment course and prognosis of these patients.


Assuntos
Ceratocone , Ceratomileuse Assistida por Excimer Laser In Situ , Ceratectomia Fotorrefrativa , Humanos , Estudos Retrospectivos , Dilatação Patológica/patologia , Dilatação Patológica/cirurgia , Córnea/patologia , Ceratectomia Fotorrefrativa/métodos , Ceratocone/diagnóstico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer , Topografia da Córnea/métodos
15.
Int Ophthalmol ; 44(1): 111, 2024 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-38403780

RESUMO

PURPOSE: To compare refractive outcomes after transepithelial photorefractive keratectomy (tPRK) and combined phototherapeutic keratectomy (PTK-PRK) procedure using two different excimer laser platforms for correction of myopia and myopic astigmatism. METHODS: In this retrospective multicenter study, we compared the results of two different PRK methods. The first group received a tPRK treatment with the Amaris750 excimer laser (Schwind eye-tech solutions). The second group received a combined PTK-PRK treatment with the MEL90 excimer laser (Carl Zeiss). Only healthy eyes with no previous surgery and a spherical equivalent (SE) of -1 to -8 diopters (D) were included. Preoperative spherical equivalent (SE), age, and sex were matched among the two groups. All treatments were performed by the same surgeon in different clinics. This study was approved by the local Ethics Committee (No. 2022-1980). RESULTS: We included 154 eyes of 86 patients in our study. There was no difference in predictability of SE between the two groups. Efficacy and safety indices were equally high in both groups. Similarly, no significant differences were seen in change of higher order aberrations (HOA) between the two groups (p > 0.05). No complications occurred. CONCLUSION: Both investigated methods provide safe and effective refractive results. The combination of PTK with PRK may be a suitable option to the already used one-step tPRK for the correction of myopia.


Assuntos
Astigmatismo , Miopia , Ceratectomia Fotorrefrativa , Humanos , Ceratectomia Fotorrefrativa/métodos , Astigmatismo/cirurgia , Astigmatismo/complicações , Acuidade Visual , Refração Ocular , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Miopia/complicações , Córnea/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
16.
J Refract Surg ; 40(2): e117-e124, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38346121

RESUMO

PURPOSE: To discuss the prevention and treatment of persistent epithelial defects after the most common refractive surgeries-photorefractive keratectomy, laser in situ keratomileusis, or small incision lenticule extraction. METHODS: PubMed was used to search the medical literature. RESULTS: Persistent epithelial defects are infrequent after photorefractive keratectomy, laser in situ keratomileusis, or small incision lenticule extraction. In the authors' opinion, any persistent epithelial defect present at 1 week or beyond after surgery should be treated aggressively with a properly fit bandage contact lens, lubrication with non-preserved artificial tears, and treatment of any eyelid abnormalities, including nocturnal lagophthalmos. Consideration should be given for presumptive treatment for herpes simplex virus or varicella zoster virus infection. If the persistent epithelial defect does not close within 2 weeks, then other measures should be considered, such as autologous serum drops, topical losartan, amniotic membranes, and topical human recombinant nerve growth factor to limit corneal scarring fibrosis and microbial infection. CONCLUSIONS: Persistent epithelial defects are among the most feared complications of refractive surgery. Timely and aggressive treatment should be instituted to close the epithelium prior to the development of scarring fibrosis and/or microbial corneal infection. [J Refract Surg. 2024;40(2):e117-e124.].


Assuntos
Doenças da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Ceratectomia Fotorrefrativa , Humanos , Cicatriz , Ceratectomia Fotorrefrativa/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Fibrose , Lasers de Excimer/uso terapêutico
17.
J Refract Surg ; 40(2): e73-e78, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38346124

RESUMO

PURPOSE: To identify risk factors that increase the likelihood of re-treatment following refractive surgery in patients with mixed astigmatism. METHODS: This was a retrospective study including patients who underwent either laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) between 2000 and 2019 and had mixed astigmatism (spherical error of +0.50 D or greater and spherical equivalent of less than 0.00 diopters [D]). Patients were divided into two groups according to whether they underwent re-treatments during the study period. RESULTS: Overall, 785 eyes (785 patients) were included. In total, 5.2% of the eyes (n = 41) underwent re-treatment. The re-treatment group was more likely to have preoperative high astigmatism (80.5% vs 48.3%, P < .001), moderate to high hyperopia (36.6% vs 22.3%, P = .035), and to have undergone surgery earlier during the study period (P < .001). They were also more likely to have undergone surgery using the Wave-Light EX200 rather than the EX500 laser platform (Alcon Laboratories, Inc) (P < .001), have a treated optical zone of 6 mm rather than 6.5 mm (P < .001 for both), and their maximum ablation depth was greater (P < .001). There was no difference between the re-treatment and control groups regarding procedure type (PRK vs LASIK). Binary logistic regression found preoperative high astigmatism (odds ratio = 3.97, P < .001) and the type of laser platform used (EX200, odds ratio = 7.78, P < .001) as the only independent factors associated with re-treatment. CONCLUSIONS: Re-treatment rates following correction of mixed astigmatism were 5.2% over 20 years. Use of a sixth-generation laser platform significantly reduced the risk of re-treatment. Presence of high astigmatism is a significant risk factor for re-treatment. There was no difference in retreatment risk between PRK and LASIK. [J Refract Surg. 2024;40(2):e73-e78.].


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Humanos , Córnea/cirurgia , Astigmatismo/cirurgia , Astigmatismo/etiologia , Acuidade Visual , Estudos Retrospectivos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Miopia/etiologia , Ceratectomia Fotorrefrativa/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Resultado do Tratamento
18.
J Cataract Refract Surg ; 50(5): 523-533, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38288954

RESUMO

Corneal crosslinking (CXL) is used for treating keratoconus and post-laser in situ keratomileusis ectasia. However, refractive surgery is not usually performed with prophylactic CXL. Therefore, we performed a meta-analysis comparing outcomes of refractive surgeries with vs without prophylactic CXL. We systematically searched databases for studies comparing refractive surgeries for myopic correction with vs without prophylactic corneal crosslinking. Review Manager 5.4.1 was used to perform statistical analysis. We included 2820 eyes from 28 studies. Compared with refractive surgery alone, surgery with prophylactic CXL resulted in decreased central corneal thickness, corrected distance visual acuity logMAR, and safety and efficacy indices. There were no significant differences in postoperative uncorrected distance visual acuity of 20/20 or better at ≥12 months and other visual outcomes among both groups. More randomized controlled trials with standard crosslinking protocols are needed to analyze the prophylactic use of crosslinking with refractive surgeries.


Assuntos
Colágeno , Reagentes de Ligações Cruzadas , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Fármacos Fotossensibilizantes , Riboflavina , Acuidade Visual , Humanos , Reagentes de Ligações Cruzadas/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Riboflavina/uso terapêutico , Colágeno/metabolismo , Acuidade Visual/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Ceratectomia Fotorrefrativa/métodos , Fotoquimioterapia/métodos , Lasers de Excimer/uso terapêutico , Substância Própria/metabolismo , Substância Própria/cirurgia , Raios Ultravioleta , Ceratocone/fisiopatologia , Ceratocone/metabolismo , Ceratocone/cirurgia , Ceratocone/tratamento farmacológico , Cirurgia da Córnea a Laser/métodos , Refração Ocular/fisiologia
19.
Cornea ; 43(3): 307-314, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37543736

RESUMO

PURPOSE: This study aimed to evaluate the efficacy and safety of Keraring implantation followed by simultaneous topography-guided photorefractive keratectomy (TGPRK) and corneal cross-linking (CXL) in the management of keratoconus. METHODS: This is a single-center, private practice, retrospective review. Patients with keratoconus who were intolerant to contact lens wear underwent implantation of the Keraring, followed by TGPRK with CXL from 2 to 36 months after implantation. Main outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction (cylinder and spherical equivalent), keratometry (steep, maximum, and central), and central corneal thickness (CCT). Patients were followed up for 3 to 60 months postoperatively. RESULTS: Fifty-seven eyes from 45 patients were included. The mean time between Keraring and TGPRK/CXL was 6.0 ± 6.0 months. Patients were followed up for a mean of 28.6 ± 20.1 months after Keraring insertion. At 12-month follow-up, there was a statistically significant improvement in mean UDVA (0.94 ± 0.49-0.35 ± 0.23, P < 0.01), CDVA (0.39 ± 0.26-0.17 ± 0.15, P < 0.01), cylinder (-4.97 ± 2.68 to -1.74 ± 1.25, P < 0.01), steep keratometry (51.25 ± 3.37-45.03 ± 2.27, P < 0.01), central keratometry (52.59 ± 4.98-46.99 ± 3.53, P < 0.01), and maximum keratometry (58.78 ± 4.22-50.76 ± 3.42, P < 0.01). These results were sustained at 48-month follow-up. CCT decreased at 12 months after TGPRK (461.84 ± 27.46-418.94 ± 45.62, P < 0.01) and remained stable at 60 months. Postoperatively, 2 eyes (3.51%) had corneal haze, resulting in decrease in CDVA; 1 was treated successfully with repeat PRK; and 1 patient (1.75%) had wound melt due to partial Keraring extrusion, which settled with repositioning. CONCLUSIONS: Keraring implantation followed by simultaneous TGPRK and CXL appears to be effective in the long term in improving UDVA, CDVA, cylinder, CCT, and keratometry in patients with keratoconus who are intolerant to contact lenses.


Assuntos
Lentes de Contato , Ceratocone , Ceratectomia Fotorrefrativa , Humanos , Ceratectomia Fotorrefrativa/métodos , Ceratocone/tratamento farmacológico , Ceratocone/cirurgia , Crosslinking Corneano , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Substância Própria/cirurgia , Topografia da Córnea , Reagentes de Ligações Cruzadas/uso terapêutico
20.
Cornea ; 43(3): 285-294, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37699556

RESUMO

PURPOSE: The aim of this study was to report the 12 to 96 months results of a tissue-preservation algorithm based on ray-tracing-guided transepithelial excimer laser central corneal ablation (RT t-PRK) combined with individualized pachymetry-guided accelerated crosslinking (M nomogram ACXL) in young adult patients with stable keratoconus (KC). METHODS: This was a prospective interventional study including 38 eyes of 38 young adult patients (stage II KC) with a mean age of 35 years (range 26-46 years) who underwent simultaneous RT with t-PRK plus pachymetry-based ACXL in the worst eye. The treatments were performed using the iViS Suite iRES Excimer Laser (Ligi, Taranto, Italy). Ray-tracing-guided treatments were planned using the customized interactive programmed transepithelial ablation (CIPTA) 2 web software and diagnostic data were assessed by the Precisio 2 tomographer (Ligi, Taranto, Italy) and Sirius tomographer (C.S.O., Florence, Italy). The main outcome measures included uncorrected distance visual acuity, best spectacle-corrected visual acuity, Kmax, high-order aberrations, minimum corneal thickness, and posterior elevation, with a mean follow-up of 52 months (range 12-96 m). RESULTS: The mean UDVA improved + 3.5 ±1.28 Snellen lines (SL); 38% gained ≥ 4 ±1.34 SLs, 35% ≥ 3 ±1.21 SLs, 22% ≥ 2 ±1.12 SLs, and 5% ≥ 1 ±0.75 SLs. The mean best spectacle-corrected visual acuity increased by + 4.3 ±1.3 SL. Sixty-eight percent gained ≥ 4 ±0.88 SLs and 30% ≥ 3 ±0.78 SL. No SLs were lost. CONCLUSIONS: RT t-PRK plus ACXL significantly improved the quality of vision in patients with KC, preventing overcorrection and minimizing tissue consumption.


Assuntos
Ceratocone , Ceratectomia Fotorrefrativa , Adulto Jovem , Humanos , Adulto , Pessoa de Meia-Idade , Ceratocone/tratamento farmacológico , Ceratocone/cirurgia , Lasers de Excimer/uso terapêutico , Estudos Prospectivos , Topografia da Córnea/métodos , Córnea/cirurgia , Reagentes de Ligações Cruzadas/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico , Ceratectomia Fotorrefrativa/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...