Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Niger J Clin Pract ; 21(4): 451-455, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29607856

RESUMO

AIM: This study aims to report the outcomes of new-generation hybrid contact lenses for visual rehabilitation of postkeratoplasty patients. MATERIALS AND METHODS: Twenty eyes of twenty postkeratoplasty patients were fitted with hybrid lenses. Each patient's keratometric values, ocular surface irregularity indices, central corneal thickness (CCT), uncorrected visual acuity (UCVA), spectacle-corrected visual acuity, contact lens-corrected visual acuity, contact lens fitting data, and contact lens daily wearing time were recorded. Follow-up examinations were performed at 1st week, 1st month, and 3rd month visit after successful fitting of the lenses. RESULTS: The mean age of the patients was 38.42 ± 4.89 years. The mean spherical component of refractive error was -4.46 ± 2.1 D, and the mean astigmatism was -5.31 ± 1.55 D. The median UCVA was 1.00 logarithm of the minimum angle of resolution (logMAR) which improved to 0.40 logMAR after spectacle correction. The median visual acuity with hybrid contact lenses was 0.05 logMAR. The median CCT was 544.4 µm and increased to 549.2 µm at 3 months after contact lens wear. The difference was not statistically significant (P = 0.38). The mean follow-up of patients was 4.32 ± 0.45 months. Eighteen of twenty patients reported a mean of 8.37 ± 1.95 h comfortable wearing time per day during this period. Two patients discontinued contact lens wearing due to conjunctival hyperemia. No graft-related complications such as decompensation, rejection, and infection were documented during the follow-up period. CONCLUSION: The new-generation hybrid contact lenses can be considered helpful in the visual management of postcorneal graft patients, particularly who are unable to achieve an adequate visual outcome with spectacles.


Assuntos
Astigmatismo/cirurgia , Lentes de Contato , Córnea/cirurgia , Doenças da Córnea/reabilitação , Transplante de Córnea/métodos , Ceratite/reabilitação , Acuidade Visual , Adulto , Astigmatismo/complicações , Córnea/patologia , Doenças da Córnea/fisiopatologia , Doenças da Córnea/cirurgia , Transplante de Córnea/efeitos adversos , Olho , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Erros de Refração/complicações , Resultado do Tratamento
2.
Arq Bras Oftalmol ; 80(1): 17-20, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28380096

RESUMO

PURPOSE:: To report the visual rehabilitation outcomes and complications of patients fitted with mini-scleral rigid gas-permeable (RGP) contact lenses (mini-SCLs) after penetrating keratoplasty. METHODS:: We retrospectively reviewed 27 eyes (21 patients) that were fitted with mini-SCLs between October 2013 and December 2014. We analyzed demographic data, previous corneal disorders, visual outcomes, interval from keratoplasty to contact lens fitting, topographic and specular microscope data, fitted contact lens parameters, and complications. The patients were divided into two groups according to the elapsed time since surgery: Group A, grafts with <10 years (n=14 eyes); and Group B, grafts with ≥10 years (n=13 eyes). RESULTS:: Lens use was discontinued in four eyes, and microbial keratitis developed in one eye during follow-up. No corneal graft rejection was observed. The mean interval between grafting and initial contact lens fitting was 10.6 ± 7.3 years (range: 1-29 years). The most frequent reason for keratoplasty was keratoconus (22 eyes, 81.4%). The mean contact lens-corrected visual acuity (CLCVA) was 0.09 ± 0.12 logMar (range: 0.50-0.00 logMar). The average topographic astigmatism, mean steepest keratometry (Kmax), and average cellularity on specular microscopy were 6.19 ± 3.49 diopters (D), 58.4 ± 7.8 D, and 1,231 ± 723 cells/mm2, respectively. CONCLUSIONS:: Mini-SCL use allowed successful visual rehabilitation after corneal keratoplasty, particularly in patients who required corrective lenses for low visual acuity and were unable to wear RGP contact lenses. Our results indicate that mini-scleral lenses may be an option for the treatment of corneal irregularities, such as those associated with keratoplasty.


Assuntos
Astigmatismo/cirurgia , Lentes de Contato , Ceratite/reabilitação , Ceratocone/cirurgia , Ceratoplastia Penetrante/reabilitação , Adolescente , Adulto , Idoso , Astigmatismo/complicações , Lentes de Contato/efeitos adversos , Feminino , Humanos , Ceratoplastia Penetrante/efeitos adversos , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Acuidade Visual
3.
Arq. bras. oftalmol ; 80(1): 17-20, Jan.-Feb. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-838768

RESUMO

ABSTRACT Purpose: To report the visual rehabilitation outcomes and complications of patients fitted with mini-scleral rigid gas-permeable (RGP) contact lenses (mini-SCLs) after penetrating keratoplasty. Methods: We retrospectively reviewed 27 eyes (21 patients) that were fitted with mini-SCLs between October 2013 and December 2014. We analyzed demographic data, previous corneal disorders, visual outcomes, interval from keratoplasty to contact lens fitting, topographic and specular microscope data, fitted contact lens parameters, and complications. The patients were divided into two groups according to the elapsed time since surgery: Group A, grafts with <10 years (n=14 eyes); and Group B, grafts with ≥10 years (n=13 eyes). Results: Lens use was discontinued in four eyes, and microbial keratitis developed in one eye during follow-up. No corneal graft rejection was observed. The mean interval between grafting and initial contact lens fitting was 10.6 ± 7.3 years (range: 1-29 years). The most frequent reason for keratoplasty was keratoconus (22 eyes, 81.4%). The mean contact lens-corrected visual acuity (CLCVA) was 0.09 ± 0.12 logMar (range: 0.50-0.00 logMar). The average topographic astigmatism, mean steepest keratometry (Kmax), and average cellularity on specular microscopy were 6.19 ± 3.49 diopters (D), 58.4 ± 7.8 D, and 1,231 ± 723 cells/mm2, respectively. Conclusions: Mini-SCL use allowed successful visual rehabilitation after corneal keratoplasty, particularly in patients who required corrective lenses for low visual acuity and were unable to wear RGP contact lenses. Our results indicate that mini-scleral lenses may be an option for the treatment of corneal irregularities, such as those associated with keratoplasty.


RESUMO Objetivos: Avaliar a reabilitação visual e complicações com o uso de lentes de contato rígidas gás-permeáveis mini-esclerais em pacientes submetidos ao transplante penetrante de córnea. Métodos: Estudo retrospectivo de 27 olhos (21 pacientes) adaptados com lentes de contato mini-esclerais entre outubro de 2013 e dezembro de 2014. Informações demográficas, doença corneana prévia, acuidade visual, tempo decorrido entre transplante e adaptação da lente, dados topográficos e de microscopia especular, parâmetros da lente de contato adaptada e complicações foram analisadas. Os pacientes foram divididos em dois grupos, levando em consideração o tempo decorrido do transplante de córnea: menos de 10 anos (Grupo A, n=14 olhos) e mais de 10 anos (Grupo B, n=13 olhos). Resultados: Quatro olhos desistiram do uso da lente de contato e 1 paciente apresentou quadro de ceratite infecciosa durante o período de acompanhamento. Não ocorreu episódio de rejeição de botão corneano transplantado durante o período avaliado. O tempo médio entre o transplante e a adaptação da lente de contato foi de 10,6 ± 7,3 anos (variação de 1 a 29 anos) e a causa mais frequente de ceratoplastia foi ceratocone (22 olhos, 81,4%). A acuidade visual média corrigida com lente de contato foi de 0,09 ± 0,12 logMar (variação de 0,50 a 0.00 logMar). O astigmatismo topográfico médio foi de 6,19 ± 3,49 dioptrias (D), a ceratometria média mais curva (Kmax) foi 58,4 ± 7,8 D e a celularidade média na microscopia especular foi 1.231 ± 723 células/mm2. Conclusões: Este estudo retrospectivo mostra o sucesso da adaptação de lentes de contato mini-esclerais na reabilitação visual após o transplante de córnea, especialmente em pacientes com baixa acuidade visual com óculos e intolerância ao uso de lentes de contato rígidas gás-permeáveis. Nossos resultados demonstram que as lentes de contato mini-esclerais são um opção para córneas com irregularidades corneanas, assim como aquelas após o transplante de córnea.


Assuntos
Humanos , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Astigmatismo/cirurgia , Ceratoplastia Penetrante/reabilitação , Lentes de Contato/efeitos adversos , Ceratite/reabilitação , Ceratocone/cirurgia , Complicações Pós-Operatórias , Astigmatismo/complicações , Fatores de Tempo , Acuidade Visual , Estudos Retrospectivos , Ceratoplastia Penetrante/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...