Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Mil Med ; 184(11-12): e808-e812, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31125090

RESUMO

INTRODUCTION: To evaluate the long-term refractive results of laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) performed by the military in a veteran population. MATERIALS AND METHODS: Three Department of Veterans Affairs (VA) hospital sites (Puget Sound, Buffalo, and Washington D.C.) obtained IRB approval for this multi-center study. Comprehensive ophthalmologic assessment including refraction and keratometry were obtained at the time of the long-term VA examination and compared to the patients' postoperative military records. RESULTS: Eighty patients (160 eyes) enrolled in this study. At the time of treatment, patients were 21-52 years of age. Long-term post-operative data was available from 4 to 17 years post-operatively. Fifteen percent of the treatment types were LASIK and 85% PRK. At the time of their military post-operative exam (range 3-14 months, mean 4 months), 82% of patients had uncorrected visual acuity (UCVA) of 20/20 or better, and their average manifest refraction was -0.08 D (SD ± 0.48 D). At the time of the long-term ophthalmological exam at the VA medical centers (range 4-11 years, mean of 8.2 years), 49% of patients had an UCVA of 20/20 or better and an average manifest refraction was -0.64 D (SD ± 0.69 D). CONCLUSION: This is the first long-term study evaluating refractive surgery outcomes up to 17 years in a military population. Our study demonstrates safety after refractive surgery in the military with less than 0.1D increase in myopia per year and strong keratometric stability. Other changes in the eye may be the likely cause for this observed mild refractive shift.


Assuntos
Militares/estatística & dados numéricos , Procedimentos Cirúrgicos Refrativos/normas , Tempo , Adulto , District of Columbia/epidemiologia , Feminino , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/normas , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Miopia/complicações , Miopia/cirurgia , New York/epidemiologia , Ceratectomia Fotorrefrativa/métodos , Ceratectomia Fotorrefrativa/normas , Ceratectomia Fotorrefrativa/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Período Pós-Operatório , Procedimentos Cirúrgicos Refrativos/métodos , Procedimentos Cirúrgicos Refrativos/estatística & dados numéricos , Resultado do Tratamento
2.
J Fr Ophtalmol ; 42(7): 703-710, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31130390

RESUMO

PURPOSE: To evaluate the long-term efficacy and safety of hyperopic laser in situ keratomileusis (LASIK) using the AMARIS® 750S (Schwind, Eye-tech-solutions, GmbH) excimer laser. METHODS: The medical records of one hundred eleven eyes of 62 patients who underwent LASIK for hyperopia using the AMARIS® 750S excimer laser were reviewed retrospectively. Patients were divided into three groups based on preoperative spherical equivalent (SE) refraction: low hyperopia (less than +2.50 diopters [D]), moderate hyperopia (+2.75D to +4.00D), and high hyperopia (over +4.00D). Uncorrected and best corrected visual acuity (BCVA), long-term stability of refraction, and complications were evaluated. RESULTS: Of the entire sample, the mean preoperative SE was +3.64D±1.22D. The mean age was 37.4±11.2 years (20-59). The mean follow-up for all eyes was 51 months. At the last visit, the mean SE was +0.85D±0.34D (SD) in the low hyperopia group, +1.09D±0.43D in the moderate hyperopia group, and +1.63D±0.47D in the high hyperopia group. (+1.15D±0.49D overall). Preoperative uncorrected visual acuity (UCVA) was 0.52±0.34 logMAR and increased to 0.18±0.15 logMAR at 4 years follow-up (P<0.01). There was no statistically significant difference between preoperative and postoperative BCVA. The UCVA was 0.30 logMAR or better in 100% of eyes in the low hyperopia group, 93.7% in the moderate hyperopia group, and 69.9% in the high hyperopia group (%89.2 overall). CONCLUSIONS: LASIK is safe and effective for correcting hyperopia in the short term; however, the efficacy of the procedure is limited in the patients with high hyperopia and longer follow-up.


Assuntos
Hiperopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Refração Ocular , Acuidade Visual , Adulto , Feminino , Seguimentos , Humanos , Hiperopia/fisiopatologia , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/instrumentação , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Refração Ocular/efeitos da radiação , Estudos Retrospectivos , Resultado do Tratamento , Testes Visuais , Acuidade Visual/efeitos da radiação , Adulto Jovem
4.
PLoS One ; 11(12): e0168081, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27992482

RESUMO

PURPOSE: To compare dry eye after small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK (FS-LASIK) for correcting myopia. METHODS: CENTRAL, Embase and PubMed were searched in November 2016. All randomized controlled trials (RCTs) and prospective cohorts that compared dry eye after SMILE with FS-LASIK were selected. RESULTS: Five cohorts and one RCT were identified for comparing dry eye after SMILE (291 eyes) and FS-LASIK (277 eyes). The pooled results revealed that the SMILE and FS-LASIK groups did not differ significantly in terms of Schirmer's I test (SIT) and tear film osmolarity (TFO) at any postoperative visits. By contrast, tear break up time (TBUT; p = 0.04 for one month, p < 0.001 for three months, and p = 0.02 for six months) and ocular surface disease index (OSDI; p < 0.001 for one month and three months, and p = 0.006 for six months) were significantly worse in the FS-LASIK group than in the SMILE group at follow-up. At six months postoperatively, TBUT and TFO values in both the SMILE and FS-LASIK groups and OSDI scores in the SMILE group returned to preoperative levels, but SIT values in both groups (p = 0.02 for the SMILE group and p < 0.001 for the FS-LASIK group) and OSDI in the FS-LASIK group (p < 0.001) were still statistically impaired. CONCLUSION: Dry eye after both SMILE and FS-LASIK usually occurs transiently. SMILE does not show obvious superiority over FS-LASIK by exhibiting similar and acceptable objective parameters, and SMILE may have milder subjective symptoms.


Assuntos
Cirurgia da Córnea a Laser/efeitos adversos , Cirurgia da Córnea a Laser/métodos , Síndromes do Olho Seco/epidemiologia , Síndromes do Olho Seco/etiologia , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Miopia/epidemiologia , Miopia/cirurgia , Cirurgia da Córnea a Laser/estatística & dados numéricos , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Lasers de Excimer/efeitos adversos
5.
J Fr Ophtalmol ; 39(10): 849-858, 2016 Dec.
Artigo em Francês | MEDLINE | ID: mdl-27865691

RESUMO

PURPOSE: Healthcare professionals require good quality of vision. The main objective of this study is to evaluate the satisfaction and vision quality after laser vision correction in healthcare professionals. METHODS: This is a monocentric retrospective study. An online 25-question survey was sent to ametropic physicians, surgeons and nurses who underwent corneal refractive surgery with laser-assisted in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) between July 2012 and February 2016. Questionnaire responses were recorded anonymously by the internet survey site. These patients' pre- and postoperative data were analyzed. RESULTS: In total, 2491 laser vision corrections were performed during this time frame. One hundred and fifty-eight patients were healthcare providers; 131 received the survey, and 111 responded. Ninety-nine were surgeons, 60 were medical physicians, and 32 were nurses. Ninety-one percent reported that they were satisfied with their postoperative vision quality, 63.9% even reported an improvement in their quality of vision compared with their corrected preoperative vision, 92.8% reported that they would have the procedure again, and 94.6% would recommend the procedure to a family member or a patient. Visual outcomes showed high levels of efficacy and predictability. CONCLUSION: While healthcare professionals require good quality of vision, those who had undergone laser vision correction reported the same satisfaction as the general population and would recommend the procedure to their family, friends and patients.


Assuntos
Ocupações em Saúde/estatística & dados numéricos , Ceratomileuse Assistida por Excimer Laser In Situ/reabilitação , Satisfação do Paciente/estatística & dados numéricos , Ceratectomia Fotorrefrativa/reabilitação , Acuidade Visual , Adulto , Feminino , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Ceratectomia Fotorrefrativa/efeitos adversos , Ceratectomia Fotorrefrativa/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Período Pós-Operatório , Refração Ocular/fisiologia , Estudos Retrospectivos , Inquéritos e Questionários , Adulto Jovem
6.
Vestn Oftalmol ; 132(4): 24-28, 2016.
Artigo em Russo | MEDLINE | ID: mdl-27600891

RESUMO

AIM: to study changes in intraocular pressure (IOP), volumetric ocular blood flow (OBF) rate, and biomechanical properties of the cornea after excimer laser ablation in patients with myopia of different degrees. MATERIAL AND METHODS: A total of 16 patients (32 eyes) with myopia ranging from 2.75 to 9.0 D were examined before and after LASIK. Ocular Blood Flow Analyzer (OBFA) was used to measure IOP and OBF as well as pulse amplitude and volume. Ocular Response Analyzer (ORA) was also employed to provide the following data: Goldmann-equivalent IOP, corneal compensated IOP, corneal hysteresis, and corneal resistance factor. The eyes were then divided into two groups: group 1 - 15 eyes with less than 70-µm deep ablation of the cornea and group 2 - 17 eyes with more than 70-µm deep ablation. RESULTS: Group 1 demonstrated a statistically reliable decrease in IOP values provided by either method and biomechanical parameters of the cornea (p<0.005), but no difference in pre- and postoperative OBF, or pulse amplitude, or pulse volume (p>0.05). In group 2, all the parameters changed reliably, except for the pulse volume (p>0.05). In particular, a decrease was recorded for IOP (with no dependence to the method of measurement; p<0.001), pulse amplitude (p<0.01), corneal hysteresis (p<0.001), and corneal resistance factor (p<0.001); an increase - for OBF (p<0.05). CONCLUSION: One should allow for possible mismeasurement of IOP and OBF as well as biomechanical parameters of the cornea in post-LASIK patients, keeping in mind that the extent of error depends on the depth of ablation. Shallow ablation (no more than 70-µm deep) has no statistically significant effect on OBF readings, while IOP seems to decrease considerably. In deep ablation (more than 70-µm deep), both parameters are reliably lower than at baseline.


Assuntos
Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Adulto , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Córnea/fisiopatologia , Diagnóstico Precoce , Feminino , Glaucoma/diagnóstico , Glaucoma/etiologia , Glaucoma/prevenção & controle , Humanos , Pressão Intraocular , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Masculino , Miopia/complicações , Miopia/diagnóstico , Miopia/fisiopatologia , Miopia/cirurgia , Reprodutibilidade dos Testes , Tonometria Ocular/métodos , Resultado do Tratamento
7.
Zhonghua Yan Ke Za Zhi ; 52(1): 41-6, 2016 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-26899220

RESUMO

OBJECTIVE: To explore the incidence of intraoperative and early postoperative complications associated with the WaveLight FS200 femtosecond laser-assisted flap creation in LASIK surgery. METHODS: A consecutive series of 400 patients (786 eyes) who underwent LASIK using the WaveLight FS200 femtosecond laser from March 2011 to December 2012 were included in this retrospective study. Intraoperative and early postoperative complications were described and analyzed. RESULTS: The intraoperative complications included suction loss (two eyes, 0.25%), incomplete flap creation (one eye, 0.13%), severe opaque bubble layers (three eyes, 0.38%), anterior chamber gas bubbles (eight eyes, 1.02%), skip lines (12 eyes, 1.53%), and corneal epithelial defects (eight eyes, 1.02%). The early postoperative complications included canal bleeding (eight eyes, 1.02%), diffuse lamellar keratitis (23 eyes, 2.93%), haze (six eyes, 0.76% ), and flap dislocation (one eye, 0.13% ). CONCLUSIONS: Intraoperative and early postoperative complications of LASIK using the WaveLight FS200 were relatively mild. All patients could obtain satisfactory clinical results with proper treatment.


Assuntos
Complicações Intraoperatórias/epidemiologia , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Câmara Anterior , Substância Própria/lesões , Humanos , Incidência , Ceratite/epidemiologia , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Estudos Retrospectivos , Retalhos Cirúrgicos
8.
Rev. cuba. oftalmol ; 27(3): 427-438, jul.-set. 2014. ilus, tab
Artigo em Espanhol | LILACS, CUMED | ID: lil-744020

RESUMO

OBJETIVO: describir las características de la superficie corneal posterior en córneas normales y las modificaciones de esta en pacientes a quienes se les realizó queratomileusis con láser in situ. MÉTODOS: fue realizado un estudio descriptivo, longitudinal y prospectivo en 282 ojos de pacientes que asistieron a la consulta de cirugía refractiva. Las variables estudiadas fueron: queratometría media central posterior, equivalente esférico, paquimetría óptica en la posición más delgada, astigmatismo topográfico anterior y posterior, astigmatismo refractivo y variación morfológica del mapa topográfico de elevación posterior respecto a la esfera de mejor ajuste. Fueron escogidos 27 ojos, los cuales reunían los criterios para cirugía refractiva láser y se les realizó la técnica queratomileusis con láser in situ. Se analizaron también las variables cantidad de ablación, estroma residual y diferencia de elevación posterior corneal, esta última obtenida del mapa de diferencia del tomógrafo Pentacam HR. RESULTADOS: la queratometría media posterior fue de -6,37 ± 0,22 dioptrías; la correlación entre la queratometría media posterior con respecto a la paquimetría óptica fue muy significativa (p= 0,008). La media de la diferencia de elevación máxima con respecto a la esfera de mejor ajuste posterior fue 5,33 µm; el 93,3 % de la muestra se encontraba dentro de valores normales. La diferencia de elevación posterior a través del tiempo fue de 18,38 µm ± 7,47 al mes y 14,95 µm ± 10,02. Se observó relación con la paquimetría y el estroma residual. CONCLUSIONES: la queratomileusis con láser in situ determina modificaciones en la superficie corneal posterior. El estroma residual es el factor más relacionado con estas modificaciones.


OBJECTIVE: to describe the characteristics of the posterior corneal surface in normal corneas and its changes in patients who underwent laser in situ keratomileusis. METHODS: prospective, longitudinal and descriptive study of 282 eyes from patients who went to the refractive surgery service. The studied variables were posterior central mean keratomery, spheral equivalent, optical pakimetry at the thinnest position, anterior and posterior topographic astigmatism, refractive astigmatism and morphological variation of the posterior elevation topographic map in relation to the best fit sphere. In this group, 27 eyes were selected, which met the criteria for laser refractive surgery using the laser in situ keratomileusis. Other analyzed variables were ablation amount, residual stroma and posterior corneal elevation difference, being the latter taken from the difference map outlined with the Pentacam HR tomography. RESULTS: mean posterior keratometry was -6,37 ± 0,22 dioptries; the correlation between mean posterior keratometry and optical pakimetry was very significant (p= 0,008). The mean difference of maximum elevation with respect to the best posterior fit sphere was 5,33 µm; 93,3 % of the sample was within the normal values. The correlation between the posterior elevation and the spheral equivalent was also significant (p= 0,019). The difference of the posterior elevation throughout the period was 18,38 µm ± 7,47 after a month and 14,95 µm ± 10,02 at the end of the period. There was correlation with pakimetry and residual stroma. CONCLUSIONS: laser in situ keratomileusis causes changes in the posterior corneal surface. The residual stroma is the factor most related with these changes.


Assuntos
Humanos , Astigmatismo/diagnóstico , Substância Própria , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Paquimetria Corneana/métodos , Epidemiologia Descritiva , Estudos Prospectivos , Estudos Longitudinais , Estudo Observacional
9.
Arq Bras Oftalmol ; 76(5): 296-300, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24232944

RESUMO

PURPOSE: Identify ideal profiles in patients undergoing to photorefractive laser surgery with the aid of an automated pupillometry and psychometric analysis of patients with visual function questionnaire (VQF 25). METHODS: Seventy-seven patients undergoing photorefractive laser surgery laser (LASIK) were analyzed with the aid of an automated digital pupillometer based on an infrared camera coupled to the optical head of a videokeratography system. Patients underwent complete ophthalmic evaluation and documentation of the pupillary behavior under different intensities of illumination, simulating situations of everyday life. Visual quality function questionnaire, translated to Portuguese was assessed. RESULTS: All patients, regardless of pupillary change under varying conditions of illumination (scotopic, mesopic and photopic) showed improvement in all sub-groups of the VQF 25. Pupil diameter was not the primary determinant of patients' visual satisfaction. CONCLUSION: Despite digital pupillometer has proven to be a useful tool in documenting and understanding of pupil behavior, a set of factors such as psycho-social profile, preoperative ametropy and final residual ametropy, contributed decisively to determine the degree of satisfaction of patients undergoing LASIK.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ/psicologia , Reflexo Pupilar/fisiologia , Acuidade Visual/fisiologia , Adulto , Feminino , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Ceratectomia Fotorrefrativa/psicologia , Ceratectomia Fotorrefrativa/estatística & dados numéricos , Psicometria , Inquéritos e Questionários , Adulto Jovem
10.
Klin Monbl Augenheilkd ; 230(4): 337-41, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23629773

RESUMO

BACKGROUND: To evaluate outcomes after optimized laser in situ keratomileusis (LASIK) for astigmatism correction with flap created by a mechanical microkeratome or a femtosecond laser. PATIENTS AND METHODS: In this retrospective study, a total of 102 eyes of 71 consecutive patients were enrolled undergoing optimized LASIK treatments using the Allegretto laser system (WaveLight Laser Technologie AG, Erlangen, Germany). A mechanical microkeratome for flap creation was used (One Use, Moria®) in 46 eyes (31 patients, spherical equivalent [SE] -4.44 D ± 2.4) and a femtosecond laser was used (LDV, Ziemer®) in 56 eyes (40 patients, spherical equivalent [SE] -3.07 D ± 3.3). The two groups were matched for inclusion criteria and were operated under similar conditions by the same surgeon. RESULTS: Overall, the preoperative spherical equivalent was -9.5 diopters (D) to +3.37 D; the preoperative manifest astigmatism was between -1.5 D and -3.5 D. At 6 months postoperatively, the mean postoperative uncorrected distance visual acuity (UDVA) was 0.93 ± 0.17 (range 0.4 to 1.2) in the Moria group and 1.0 ± 0.21 (range 0.6 to 1.6) in the Femto group, which was statistically significant (p = 0.003). Comparing the cylinder power there was a statistical difference between the two groups (p = 0.0015). CONCLUSIONS: This study shows that the method of flap creation has a significant impact on postoperative astigmatism with a significantly better postoperative UDVA in the Femto group. These findings suggest that the femtosecond laser provides a better platform for LASIK treatment of astigmatism than the commonly used microkeratome.


Assuntos
Astigmatismo/epidemiologia , Astigmatismo/cirurgia , Retalhos de Tecido Biológico/estatística & dados numéricos , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Microcirurgia/estatística & dados numéricos , Adulto , Astigmatismo/diagnóstico , Feminino , Humanos , Masculino , Prevalência , Estudos Retrospectivos , Medição de Risco , Suíça/epidemiologia , Resultado do Tratamento
11.
J Refract Surg ; 29(5): 303-10, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23659228

RESUMO

PURPOSE: To evaluate the causes of laser programming errors in refractive surgery and outcomes in these cases. METHODS: In this multicenter, retrospective chart review, 22 eyes of 18 patients who had incorrect data entered into the refractive laser computer system at the time of treatment were evaluated. Cases were analyzed to uncover the etiology of these errors, patient follow-up treatments, and final outcomes. The results were used to identify potential methods to avoid similar errors in the future. RESULTS: Every patient experienced compromised uncorrected visual acuity requiring additional intervention, and 7 of 22 eyes (32%) lost corrected distance visual acuity (CDVA) of at least one line. Sixteen patients were suitable candidates for additional surgical correction to address these residual visual symptoms and six were not. Thirteen of 22 eyes (59%) received surgical follow-up treatment; nine eyes were treated with contact lenses. After follow-up treatment, six patients (27%) still had a loss of one line or more of CDVA. Three significant sources of error were identified: errors of cylinder conversion, data entry, and patient identification error. CONCLUSION: Twenty-seven percent of eyes with laser programming errors ultimately lost one or more lines of CDVA. Patients who underwent surgical revision had better outcomes than those who did not. Many of the mistakes identified were likely avoidable had preventive measures been taken, such as strict adherence to patient verification protocol or rigorous rechecking of treatment parameters.


Assuntos
Hiperopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Lasers de Excimer/efeitos adversos , Erros Médicos/estatística & dados numéricos , Miopia/cirurgia , Ceratectomia Fotorrefrativa/estatística & dados numéricos , Transtornos da Visão/etiologia , Adulto , Topografia da Córnea , Feminino , Seguimentos , Humanos , Hiperopia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Refração Ocular/fisiologia , Reoperação , Estudos Retrospectivos , Software , Transtornos da Visão/fisiopatologia , Transtornos da Visão/cirurgia , Acuidade Visual/fisiologia
13.
Health Econ ; 20(6): 699-722, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20568101

RESUMO

In this article, we use a longitudinal census of laser in situ keratomileusis (LASIK) eye surgeries collected directly from patient charts to examine the learning-by-doing hypothesis in medicine. LASIK surgery has precise measures of presurgical condition and postsurgical outcomes. Unlike other types of surgery, the impact of unobservable underlying patient conditions on outcomes is minimal. Individual learning by doing is identified through observations of surgical outcomes over time, based on the cumulative number of surgeries performed. Collective learning is identified separately, through changes in a group adjustment rule determined jointly by all the surgeons in a structured internal review process. Our unique data set overcomes some of the measurement problems in patient outcomes encountered in other studies and improves the possibility of identifying and separating the impact of learning by doing from other effects. We cannot conclude that the outcome of LASIK surgery improves as an individual surgeon's experience increases, but we find strong evidence that experience accumulated by surgeons as a group in a clinic significantly improves outcomes.


Assuntos
Competência Clínica/normas , Ceratomileuse Assistida por Excimer Laser In Situ , Médicos , Adulto , Colômbia , Feminino , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Masculino , Auditoria Médica , Modelos Econométricos , Avaliação de Resultados em Cuidados de Saúde , Cuidados Pós-Operatórios
14.
Klin Monbl Augenheilkd ; 228(6): 531-6, 2011 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-21108166

RESUMO

LASIK has become the preferred surgical procedure for the correction of refractive errors. Microbial keratitis is a rare but severe complication. The incidence of post-LASIK keratitis, (uni- and bilateral) is difficult to estimate. The risk of bilateral infection could until now only be approximated by calculating it from the risk of unilateral infection. Due to the fortunately low incidence of post-LASIK keratitis, large-scale studies are necessary to obtain valid statistical data. The American Society of Cataract and Refractive surgery (ASCRS) developed a post-LASIK infectious keratitis survey in 2001. 116 post-LASIK infections were reported by the members of the society. The calculated incidence was 0.035 % or 1 infection in every 2919 procedures. Llovet et al. found 9 patients (18 eyes) with bilateral post-LASIK keratitis out of 204 586 procedures (incidence 0.0084 %). Gram-positive bacteria and atypical mycobacteria are the most common causes for microbial post-LASIK keratitis. There is an increasing literature of post-LASIK case reports caused by rare or atypical species. Severe cases of keratitis are more often correlated with a prolonged onset of infection and caused by atypical species. An overview of the current literature and our own data regarding post-LASIK keratitis (uni-, and bilateral) are presented.


Assuntos
Ceratite/epidemiologia , Ceratite/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Comorbidade , Humanos , Incidência , Medição de Risco
15.
J Biomech Eng ; 133(1): 011002, 2011 01.
Artigo em Inglês | MEDLINE | ID: mdl-21186892

RESUMO

The purpose of this study is to develop a 3D patient-specific finite element model (FEM) of the cornea and sclera to compare predicted and in vivo refractive outcomes and to estimate the corneal elastic property changes associated with each procedure. Both eyes of a patient who underwent laser-assisted in situ keratomileusis (LASIK) for myopic astigmatism were modeled. Pre- and postoperative Scheimpflug anterior and posterior corneal elevation maps were imported into a 3D corneo-scleral FEM with an unrestrained limbus. Preoperative corneal hyperelastic properties were chosen to account for meridional anisotropy. Inverse FEM was used to determine the undeformed corneal state that produced <0.1% error in anterior elevation between simulated and in vivo preoperative geometries. Case-specific 3D aspheric ablation profiles were simulated, and corneal topography and spherical aberration were compared at clinical intraocular pressure. The magnitude of elastic weakening of the residual corneal bed required to maximize the agreement with clinical axial power was calculated and compared with the changes in ocular response analyzer (ORA) measurements. The models produced curvature maps and spherical aberrations equivalent to in vivo measurements. For the preoperative property values used in this study, predicted elastic weakening with LASIK was as high as 55% for a radially uniform model of residual corneal weakening and 65% at the point of maximum ablation in a spatially varying model of weakening. Reductions in ORA variables were also observed. A patient-specific FEM of corneal refractive surgery is presented, which allows the estimation of surgically induced changes in corneal elastic properties. Significant elastic weakening after LASIK was required to replicate clinical topographic outcomes in this two-eye pilot study.


Assuntos
Simulação por Computador , Córnea/fisiologia , Córnea/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Adulto , Astigmatismo/cirurgia , Fenômenos Biomecânicos , Engenharia Biomédica , Córnea/anatomia & histologia , Topografia da Córnea/estatística & dados numéricos , Elasticidade , Feminino , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Miopia/cirurgia , Resultado do Tratamento
16.
Ophthalmologe ; 107(5): 439-45, 2010 May.
Artigo em Alemão | MEDLINE | ID: mdl-19777246

RESUMO

OBJECTIVE: For technical reasons, the rotating knives (microkeratomes) commonly used for flap creation in LASIK may induce cut complications such as buttonholes or incomplete flaps. Femtosecond (femto) lasers should reduce these risks because, compared with microceratomes, femtolasers work more precisely and individually, so the flap can be individualized according to the patient's eye condition. Therefore, surgery should be less of a strain to patients, vision should recover faster, and optical quality should be optimized. METHODS: In this study, 308 consecutive femtolaser cuts for myopic LASIK performed with the IntraLase FS60 between August 2006 and March 2008 were evaluated and compared with the approved key literature. RESULTS: For all cuts, just three complications (incomplete ring cuts of about 20 degrees) occurred. All were completed with a diamond knife without any further problems. No other complications - including the typical microceratome-induced cut complications - were observed. CONCLUSIONS: In this small series of 308 operations, femto-LASIK induced no major cut complications.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Erros de Refração/epidemiologia , Comorbidade , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Resultado do Tratamento
17.
Korean J Ophthalmol ; 23(3): 142-7, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19794938

RESUMO

PURPOSE: This purpose of this report was to study trends in cataract and refractive surgeries conducted during the past twelve years and to compare results to previous reports from the ASCRS and New Zealand (NZ) in order to forecast future medical services. METHODS: We surveyed members of the Korean Society of Cataract and Refractive Surgery (KSCRS) every year from 1995 to 2006, and studied changes in cataract and refractive surgeries (RS). RESULTS: The duration of hospitalization has been gradually decreasing to the point that a one day hospitalization following surgery has become common. The rate of topical anesthesia use has significantly increased since 1998. Sutureless incision methods are now commonly practiced. The use of acryl IOL as an optic material has been gradually increasing for cataract surgeries. KSCRS members showed an interest in the special intraocular lenses as multifocal IOL. While Excimer laser PRK was the most popular refractive surgery during the first stage, KSCRS members increasingly prefer LASIK to the Excimer laser PRK. Regression of the corrected visual acuity, dry eye, night halo, and flashes were the most common complications following refractive surgeries. Medical disputes related to PRK and LASIK have been gradually increasing throughout the study period. CONCLUSIONS: We confirm that the KSCRS practice styles for cataract and RS are similar to those of the ASCRS and NZ. We infer a world-wide trend from the comparison of these three societies.


Assuntos
Extração de Catarata/tendências , Oftalmologia/tendências , Prática Profissional/tendências , Procedimentos Cirúrgicos Refrativos/tendências , Adulto , Extração de Catarata/estatística & dados numéricos , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Ceratomileuse Assistida por Excimer Laser In Situ/tendências , Terapia a Laser/estatística & dados numéricos , Terapia a Laser/tendências , Lasers de Excimer , Lentes Intraoculares/estatística & dados numéricos , Lentes Intraoculares/tendências , Pessoa de Meia-Idade , Oftalmologia/estatística & dados numéricos , Ceratectomia Fotorrefrativa/estatística & dados numéricos , Ceratectomia Fotorrefrativa/tendências , Prática Profissional/estatística & dados numéricos , Procedimentos Cirúrgicos Refrativos/estatística & dados numéricos , República da Coreia , Sociedades Médicas , Inquéritos e Questionários
18.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-54008

RESUMO

PURPOSE: This purpose of this report was to study trends in cataract and refractive surgeries conducted during the past twelve years and to compare results to previous reports from the ASCRS and New Zealand (NZ) in order to forecast future medical services. METHODS: We surveyed members of the Korean Society of Cataract and Refractive Surgery (KSCRS) every year from 1995 to 2006, and studied changes in cataract and refractive surgeries (RS). RESULTS: The duration of hospitalization has been gradually decreasing to the point that a one day hospitalization following surgery has become common. The rate of topical anesthesia use has significantly increased since 1998. Sutureless incision methods are now commonly practiced. The use of acryl IOL as an optic material has been gradually increasing for cataract surgeries. KSCRS members showed an interest in the special intraocular lenses as multifocal IOL. While Excimer laser PRK was the most popular refractive surgery during the first stage, KSCRS members increasingly prefer LASIK to the Excimer laser PRK. Regression of the corrected visual acuity, dry eye, night halo, and flashes were the most common complications following refractive surgeries. Medical disputes related to PRK and LASIK have been gradually increasing throughout the study period. CONCLUSIONS: We confirm that the KSCRS practice styles for cataract and RS are similar to those of the ASCRS and NZ. We infer a world-wide trend from the comparison of these three societies.


Assuntos
Adulto , Humanos , Pessoa de Meia-Idade , Extração de Catarata/estatística & dados numéricos , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Terapia a Laser/estatística & dados numéricos , Lasers de Excimer , Lentes Intraoculares/estatística & dados numéricos , Oftalmologia/estatística & dados numéricos , Ceratectomia Fotorrefrativa/estatística & dados numéricos , Prática Profissional/estatística & dados numéricos , Inquéritos e Questionários , Procedimentos Cirúrgicos Refrativos/estatística & dados numéricos , República da Coreia , Sociedades Médicas
19.
Clin Exp Ophthalmol ; 36(7): 604-19, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18983545

RESUMO

BACKGROUND: To examine the current practice and changing trends for cataract and refractive surgery in New Zealand (NZ) between 1997 and 2007. METHODS: A self-administered confidential postal questionnaire was sent to all consultant ophthalmologists practising in NZ in 2007, eliciting surgical volumes and technique, anaesthetic, preferred equipment and patient management. Results were compared with previous NZ surveys and international surveys of surgeons in Northern America, Europe and the UK. RESULTS: From the 113 ophthalmologists surveyed 88% responded, comprising 86 cataract surgeons and 20 refractive surgeons. Key findings for cataract surgeons were: 65% routinely used sub-Tenon's anaesthetic, 20% topical anaesthetic, 24% favoured intracameral antibiotics, 88% operated via clear corneal or anterior limbal incisions and 61% used temporal incisions. Acrylic foldable intraocular lenses (IOLs) were preferred, 27% of surgeons routinely used aspheric IOLs, 31% used presbyopia-correcting IOLs and 63% expressed high interest in toric IOLs. Of the refractive surgeons, 83% would perform bilateral LASIK at the same surgical event; phakic IOL was the treatment of choice for 30-year-old -12D myopes, and clear lens exchange for 45-year-old +5D hyperopes. CONCLUSIONS: The majority of NZ cataract surgical practice remains comparable with results from international surveys. A notable exception, as in previous comparisons, is a lower use of topical anaesthetic in NZ with a higher use of sub-Tenon's anaesthetic instead. Refractive surgery practice in NZ is generally comparable with that of American Society of Cataract and Refractive Surgery members.


Assuntos
Extração de Catarata/estatística & dados numéricos , Catarata/terapia , Pesquisas sobre Atenção à Saúde , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Oftalmologia/estatística & dados numéricos , Prática Profissional/estatística & dados numéricos , Anestesia/métodos , Anestesia/estatística & dados numéricos , Extração de Catarata/métodos , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Nova Zelândia , Inquéritos e Questionários
20.
Clin Exp Ophthalmol ; 36(1): 54-61, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18290954

RESUMO

PURPOSE: To identify the most published authors on the topics of 'cataract' and 'LASIK', the journals in which they publish, and the citation patterns of the most-cited articles by these authors over a 5-year publication period. METHODS: Science Citation Index Expanded (SCI) was used to identify the 30 most-published authors in 'cataract' and 'laser in situ keratomileusis' (LASIK) (2000-2004 inclusive). SCI was subsequently used to analyse the recorded articles for each author in terms of source journal, the most commonly cited articles and citation source. RESULTS: Of the 30 most-published authors in the fields of cataract and LASIK, the USA was the most well-represented source country, accounting for 33%; 20% were from Australia, and 17% from Austria. Germany and Japan each contributed 7%. Eighty per cent of the publications produced by these 30 authors (2000-2004) were in 10 journals, of which the Journal of Cataract and Refractive Surgery (JCRS) published more than one-third. Of the three most-cited articles for each author, the greatest number were published in JCRS (35.6%). The citation count of the articles had a weak correlation to the journal impact factor of the source journal; however, the self-citation rate of these articles did not. CONCLUSIONS: The USA and Australia together were the source of more than half of the most-published authors on cataract and LASIK and the majority of articles published by the 30 most prolific authors were published in only 10 journals. The impact factors of the publication journals preferred by these authors are influenced by the article citation counts, not vice versa.


Assuntos
Autoria , Bibliometria , Extração de Catarata/estatística & dados numéricos , Ceratomileuse Assistida por Excimer Laser In Situ/estatística & dados numéricos , Oftalmologia , Publicações Periódicas como Assunto/estatística & dados numéricos , Austrália , Alemanha , Humanos , Japão , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...