Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21.505
Filtrar
1.
Bull Math Biol ; 86(7): 83, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38842602

RESUMO

5-Aminolevulinic Acid (5-ALA) is the only fluorophore approved by the FDA as an intraoperative optical imaging agent for fluorescence-guided surgery in patients with glioblastoma. The dosing regimen is based on rodent tests where a maximum signal occurs around 6 h after drug administration. Here, we construct a computational framework to simulate the transport of 5-ALA through the stomach, blood, and brain, and the subsequent conversion to the fluorescent agent protoporphyrin IX at the tumor site. The framework combines compartmental models with spatially-resolved partial differential equations, enabling one to address questions regarding quantity and timing of 5-ALA administration before surgery. Numerical tests in two spatial dimensions indicate that, for tumors exceeding the detection threshold, the time to peak fluorescent concentration is 2-7 h, broadly consistent with the current surgical guidelines. Moreover, the framework enables one to examine the specific effects of tumor size and location on the required dose and timing of 5-ALA administration before glioblastoma surgery.


Assuntos
Ácido Aminolevulínico , Neoplasias Encefálicas , Simulação por Computador , Glioblastoma , Conceitos Matemáticos , Modelos Biológicos , Protoporfirinas , Cirurgia Assistida por Computador , Glioblastoma/cirurgia , Glioblastoma/tratamento farmacológico , Glioblastoma/patologia , Glioblastoma/diagnóstico por imagem , Ácido Aminolevulínico/administração & dosagem , Humanos , Neoplasias Encefálicas/cirurgia , Protoporfirinas/administração & dosagem , Protoporfirinas/metabolismo , Cirurgia Assistida por Computador/métodos , Animais , Fármacos Fotossensibilizantes/administração & dosagem , Imagem Óptica/métodos , Corantes Fluorescentes/administração & dosagem
2.
Clin Orthop Surg ; 16(3): 430-440, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38827763

RESUMO

Background: Computer-assisted navigation surgery (CAS) during primary total knee arthroplasty (TKA) may help improve outcomes for patients with extra-articular deformity (EAD); however, this has not been extensively studied. Therefore, we aimed to investigate the clinical and radiological outcomes following primary TKA using CAS in patients with EAD. Methods: We searched Medline, Embase, and the Cochrane Library up to March 3, 2023 for studies investigating surgical outcomes of using the navigation system for TKA to treat patients with EAD. From 14 studies, 539 knees with EAD that underwent navigation TKA were enrolled. We investigated the knee range of motion (ROM), outcome scores at final follow-up (Knee Society Score [KSS] and Knee Functional Score [KFS]), and pre- and postoperative mechanical hip-knee-ankle (mHKA) angle using lower extremity scanogram. The meta-analysis was based on the single-arm method, and all data were pooled using a random-effects model. Results: Following our meta-analyses, the mean knee ROM changed from 87.0° (95% confidence interval [CI], 75.9°-98.1°) preoperatively to 109.4° (95% CI, 97.9°-120.8°) postoperatively. The adjusted KSS was 93.45 points (95% CI, 88.36-98.54 points), and the adjusted KFS was 91.57 points (95% CI, 86.80-96.33 points) in knees with EAD that underwent CAS-TKA. As a radiological outcome, the mHKA angle changed from 169.53° (95% CI, 166.90°-172.16°) preoperatively to 178.81° (95% CI, 178.31°-179.30°) postoperatively. Conclusions: CAS-TKA yielded positive clinical results and demonstrated a satisfactory alignment of the lower limb's mechanical axis. CAS-TKA showed promise for primary TKA procedures, demonstrating favorable clinical and radiological outcomes even in complex cases involving EAD.


Assuntos
Artroplastia do Joelho , Amplitude de Movimento Articular , Cirurgia Assistida por Computador , Humanos , Artroplastia do Joelho/métodos , Cirurgia Assistida por Computador/métodos , Articulação do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem
3.
PLoS One ; 19(6): e0304843, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38838047

RESUMO

Imaging modalities for percutaneous coronary intervention (PCI), such as intravascular ultrasound (IVUS) or optical coherence tomography (OCT), have increased in the current PCI era. However, their clinical benefits in acute myocardial infarction (AMI) have not been fully elucidated. This study investigated the long-term outcomes of image-guided PCI in patients with AMI using data from the Korean Acute Myocardial Infarction Registry. A total of 9,271 patients with AMI, who underwent PCI with second-generation drug-eluting stents between November 2011 and December 2015, were retrospectively examined, and target lesion failure (TLF) at 3 years (defined as the composite of cardiac death, target vessel myocardial infarction, and ischemia-driven target lesion revascularization) was evaluated. From the registry, 2,134 patients (23.0%) underwent image-guided PCI (IVUS-guided: n = 1,919 [20.6%]; OCT-guided: n = 215 patients [2.3%]). Based on propensity score matching, image-guided PCI was associated with a significant reduction in TLF (hazard ratio: 0.76; 95% confidence interval: 0.59-0.98, p = 0.035). In addition, the TLF incidence in the OCT-guided PCI group was comparable to that in the IVUS-guided PCI group (5.3% vs 4.7%, p = 0.903). Image-guided PCI, including IVUS and OCT, is associated with favorable clinical outcomes in patients with AMI at 3 years post-intervention. Additionally, OCT-guided PCI is not inferior to IVUS-guided PCI in patients with AMI.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Sistema de Registros , Tomografia de Coerência Óptica , Humanos , Intervenção Coronária Percutânea/métodos , Masculino , Feminino , República da Coreia/epidemiologia , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia , Infarto do Miocárdio/cirurgia , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos , Ultrassonografia de Intervenção/métodos , Stents Farmacológicos , Cirurgia Assistida por Computador/métodos
4.
Int J Med Robot ; 20(3): e2639, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38847191

RESUMO

BACKGROUND: For the fracture reduction robot, the position tracking accuracy and compliance are affected by dynamic loads from muscle stretching, uncertainties in robot dynamics models, and various internal and external disturbances. METHODS: A control method that integrates a Radial Basis Function Neural Network (RBFNN) with Nonlinear Disturbance Observer is proposed to enhance position tracking accuracy. Additionally, an admittance control is employed for force tracking to enhance the robot's compliance, thereby improving the safety. RESULTS: Experiments are conducted on a long bone fracture model with simulated muscle forces and the results demonstrate that the position tracking error is less than ±0.2 mm, the angular displacement error is less than ±0.3°, and the maximum force tracking error is 26.28 N. This result can meet surgery requirements. CONCLUSIONS: The control method shows promising outcomes in enhancing the safety and accuracy of long bone fracture reduction with robotic assistance.


Assuntos
Algoritmos , Fraturas Ósseas , Redes Neurais de Computação , Dinâmica não Linear , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Fraturas Ósseas/cirurgia , Simulação por Computador , Fenômenos Biomecânicos , Desenho de Equipamento , Robótica , Reprodutibilidade dos Testes , Cirurgia Assistida por Computador/métodos
5.
Int J Med Robot ; 20(3): e2649, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38847242

RESUMO

BACKGROUND: Endoscope retrograde cholangiopancreatography is a standard surgical treatment for gallbladder and pancreatic diseases. However, surgeons is at high risk and require sufficient surgical experience and skills. METHODS: (1) The simultaneous localisation and mapping technique to reconstruct the surgical environment. (2) The preoperative 3D model is transformed into the intraoperative video environment to implement the multi-modal fusion. (3) A framework for virtual-to-real projection based on hand-eye alignment. For the purpose of projecting the 3D model onto the imaging plane of the camera, it uses position data from electromagnetic sensors. RESULTS: Our AR-assisted navigation system can accurately guide physicians, which means a distance of registration error to be restricted to under 5 mm and a projection error of 5.76 ± 2.13, and the intubation procedure is done at 30 frames per second. CONCLUSIONS: Coupled with clinical validation and user studies, both the quantitative and qualitative results indicate that our navigation system has the potential to be highly useful in clinical practice.


Assuntos
Realidade Aumentada , Colangiopancreatografia Retrógrada Endoscópica , Imagens de Fantasmas , Cirurgia Assistida por Computador , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Imageamento Tridimensional/métodos , Sistemas de Navegação Cirúrgica , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Reprodutibilidade dos Testes
6.
J Vis Exp ; (207)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38856206

RESUMO

This protocol helps assess the accuracy and workflow of an augmented reality (AR) hybrid navigation system using the Magic Leap head-mounted display (HMD) for minimally invasive pedicle screw placement. The cadaveric porcine specimens were placed on a surgical table and draped with sterile covers. The levels of interest were identified using fluoroscopy, and a dynamic reference frame was attached to the spinous process of a vertebra in the region of interest. Cone beam computerized tomography (CBCT) was performed, and a 3D rendering was automatically generated, which was used for the subsequent planning of the pedicle screw placements. Each surgeon was fitted with an HMD that was individually eye-calibrated and connected to the spinal navigation system. Navigated instruments, tracked by the navigation system and displayed in 2D and 3D in the HMD, were used for 33 pedicle cannulations, each with a diameter of 4.5 mm. Postprocedural CBCT scans were assessed by an independent reviewer to measure the technical (deviation from the planned path) and clinical (Gertzbein grade) accuracy of each cannulation. The navigation time for each cannulation was measured. The technical accuracy was 1.0 mm ± 0.5 mm at the entry point and 0.8 mm ± 0.1 mm at the target. The angular deviation was 1.5° ± 0.6°, and the mean insertion time per cannulation was 141 s ± 71 s. The clinical accuracy was 100% according to the Gertzbein grading scale (32 grade 0; 1 grade 1). When used for minimally invasive pedicle cannulations in a porcine model, submillimeter technical accuracy and 100% clinical accuracy could be achieved with this protocol.


Assuntos
Realidade Aumentada , Parafusos Pediculares , Animais , Suínos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Modelos Animais
7.
BMC Cancer ; 24(1): 697, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38844894

RESUMO

BACKGROUND: Fluorescence-guided precision cancer surgery may improve survival and minimize patient morbidity. Efficient development of promising interventions is however hindered by a lack of common methodology. This methodology review aimed to synthesize descriptions of technique, governance processes, surgical learning and outcome reporting in studies of fluorescence-guided cancer surgery to provide guidance for the harmonized design of future studies. METHODS: A systematic search of MEDLINE, EMBASE and CENTRAL databases from 2016-2020 identified studies of all designs describing the use of fluorescence in cancer surgery. Dual screening and data extraction was conducted by two independent teams. RESULTS: Of 13,108 screened articles, 426 full text articles were included. The number of publications per year increased from 66 in 2016 to 115 in 2020. Indocyanine green was the most commonly used fluorescence agent (391, 91.8%). The most common reported purpose of fluorescence guided surgery was for lymph node mapping (195, 5%) and non-specific tumour visualization (94, 2%). Reporting about surgical learning and governance processes incomplete. A total of 2,577 verbatim outcomes were identified, with the commonly reported outcome lymph node detection (796, 30%). Measures of recurrence (32, 1.2%), change in operative plan (23, 0.9%), health economics (2, 0.1%), learning curve (2, 0.1%) and quality of life (2, 0.1%) were rarely reported. CONCLUSION: There was evidence of methodological heterogeneity that may hinder efficient evaluation of fluorescence surgery. Harmonization of the design of future studies may streamline innovation.


Assuntos
Neoplasias , Cirurgia Assistida por Computador , Humanos , Neoplasias/cirurgia , Cirurgia Assistida por Computador/métodos , Fluorescência , Verde de Indocianina , Imagem Óptica/métodos
8.
J Refract Surg ; 40(5): e336-e343, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717081

RESUMO

PURPOSE: To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS: Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS: The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS: The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].


Assuntos
Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Cirurgia Assistida por Computador , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Acuidade Visual/fisiologia , Estudos Prospectivos , Refração Ocular/fisiologia , Adulto , Masculino , Feminino , Lasers de Excimer/uso terapêutico , Método Duplo-Cego , Miopia/cirurgia , Miopia/fisiopatologia , Adulto Jovem , Cirurgia Assistida por Computador/métodos , Pessoa de Meia-Idade , Córnea/cirurgia , Córnea/fisiopatologia , Seguimentos
9.
J Nanobiotechnology ; 22(1): 224, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702709

RESUMO

Poorly identified tumor boundaries and nontargeted therapies lead to the high recurrence rates and poor quality of life of prostate cancer patients. Near-infrared-II (NIR-II) fluorescence imaging provides certain advantages, including high resolution and the sensitive detection of tumor boundaries. Herein, a cyanine agent (CY7-4) with significantly greater tumor affinity and blood circulation time than indocyanine green was screened. By binding albumin, the absorbance of CY7-4 in an aqueous solution showed no effects from aggregation, with a peak absorbance at 830 nm and a strong fluorescence emission tail beyond 1000 nm. Due to its extended circulation time (half-life of 2.5 h) and high affinity for tumor cells, this fluorophore was used for primary and metastatic tumor diagnosis and continuous monitoring. Moreover, a high tumor signal-to-noise ratio (up to ~ 10) and excellent preferential mitochondrial accumulation ensured the efficacy of this molecule for photothermal therapy. Therefore, we integrated NIR-II fluorescence-guided surgery and intraoperative photothermal therapy to overcome the shortcomings of a single treatment modality. A significant reduction in recurrence and an improved survival rate were observed, indicating that the concept of intraoperative combination therapy has potential for the precise clinical treatment of prostate cancer.


Assuntos
Carbocianinas , Mitocôndrias , Recidiva Local de Neoplasia , Terapia Fototérmica , Neoplasias da Próstata , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Terapia Fototérmica/métodos , Humanos , Animais , Mitocôndrias/metabolismo , Mitocôndrias/efeitos dos fármacos , Linhagem Celular Tumoral , Carbocianinas/química , Imagem Óptica/métodos , Camundongos , Cirurgia Assistida por Computador/métodos , Corantes Fluorescentes/química , Camundongos Nus , Camundongos Endogâmicos BALB C , Raios Infravermelhos , Verde de Indocianina/química , Verde de Indocianina/uso terapêutico , Verde de Indocianina/farmacologia
10.
Int J Med Robot ; 20(3): e2634, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38767083

RESUMO

BACKGROUND: Reducing the annotation burden is an active and meaningful area of artificial intelligence (AI) research. METHODS: Multiple datasets for the segmentation of two landmarks were constructed based on 41 257 labelled images and 6 different microsurgical scenarios. These datasets were trained using the multi-stage transfer learning (TL) methodology. RESULTS: The multi-stage TL enhanced segmentation performance over baseline (mIOU 0.6892 vs. 0.8869). Besides, Convolutional Neural Networks (CNNs) achieved a robust performance (mIOU 0.8917 vs. 0.8603) even when the training dataset size was reduced from 90% (30 078 images) to 10% (3342 images). When directly applying the weight from one certain surgical scenario to recognise the same target in images of other scenarios without training, CNNs still obtained an optimal mIOU of 0.6190 ± 0.0789. CONCLUSIONS: Model performance can be improved with TL in datasets with reduced size and increased complexity. It is feasible for data-based domain adaptation among different microsurgical fields.


Assuntos
Microcirurgia , Redes Neurais de Computação , Humanos , Microcirurgia/métodos , Inteligência Artificial , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Procedimentos Cirúrgicos Otorrinolaringológicos/métodos , Aprendizado de Máquina , Cirurgia Assistida por Computador/métodos , Pontos de Referência Anatômicos
12.
J Plast Surg Hand Surg ; 59: 46-52, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747532

RESUMO

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas Mal-Unidas , Osteotomia , Fraturas do Rádio , Humanos , Feminino , Osteotomia/métodos , Osteotomia/instrumentação , Pessoa de Meia-Idade , Fraturas do Rádio/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Idoso , Fraturas Mal-Unidas/cirurgia , Fraturas Mal-Unidas/diagnóstico por imagem , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Impressão Tridimensional , Cirurgia Assistida por Computador , Imageamento Tridimensional , Parafusos Ósseos , Tomografia Computadorizada por Raios X
13.
BMC Oral Health ; 24(1): 550, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38734597

RESUMO

BACKGROUND: Large cross-arch free-end surgical guides can obscure the visual field, compromising surgical accuracy due to insufficient stability at the free-end. This in vitro study aims to evaluate the accuracy of novel digital non-cross-arch surgical guides designed for implant placement at the mandibular free-end, incorporating tooth undercut retention and screw-bone support. MATERIALS AND METHODS: A mandibular dental model lacking left molars was utilized to fabricate unilateral (cross-arch) tooth-supported surgical guides (GT I, n = 20). Subsequently, two additional types of surgical guides were fabricated: GT II (covering two teeth, n = 20) and GT III (covering three teeth, n = 20). These novel surgical guides were designed to utilize the undercut of the supporting teeth for retention and enhance stability with screw-bone support at the guide's free-end. Furthermore, 60 identical guiding blocks were assembled on the three types of surgical guides to facilitate the implants' insertion. On a phantom head, 120 implant replicas were placed at the Federal Dentaire Internationale (FDI) teeth positions #36 and #37 on the dental model, employing a combination of surgical guides and guiding blocks. To assess accuracy, planned and placed implant positions were compared using intraoral optical scanning. Discrepancies in angulation and linear deviations, including the coronal/apical 3D deviations, lateral deviation as well as depth deviation, were measured. Statistical analysis was performed using two-way ANOVA and Bonferroni test (α = 0.05). RESULTS: GT I exhibited significantly largest discrepancies, including angular and linear deviations at the crest and apex at every implant site. Especially in depth, at implant site #36, the mean deviation value of GT I (0.27 ± 0.13 mm) was twice as large as GT III (0.13 ± 0.07 mm), and almost twice as large as GT II (0.14 ± 0.08 mm). However, at implant site #37, this deviation increased to almost a five-fold relationship between GT I (0.63 ± 0.12 mm) and II (0.14 ± 0.09 mm), as well as between GT I and III (0.13 ± 0.09 mm). No significant discrepancies existed between the novel surgical guides at either implant site #36 or #37. CONCLUSION: This study provides a practical protocol for enhancing accuracy of implant placement and reducing the size of free-end surgical guides used at mandibular molar sites.


Assuntos
Parafusos Ósseos , Mandíbula , Modelos Dentários , Cirurgia Assistida por Computador , Humanos , Mandíbula/cirurgia , Cirurgia Assistida por Computador/métodos , Implantação Dentária Endóssea/métodos , Desenho Assistido por Computador , Técnicas In Vitro
15.
BMC Oral Health ; 24(1): 582, 2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38764019

RESUMO

BACKGROUND: The operation accuracy and efficiency of dynamic navigated endodontic surgery were evaluated through in vitro experiments. This study provides a reference for future clinical application of dynamic navigation systems in endodontic surgery. MATERIALS AND METHODS: 3D-printed maxillary anterior teeth were used in the preparation of models for endodontic surgery. Endodontic surgery was performed with and without dynamic navigation by an operator who was proficient in dynamic navigation technology but had no experience in endodontic surgery. Optical scanning data were applied to evaluate the length and angle deviations of root-end resection. And the operation time was recorded. T tests were used to analyze the effect of dynamic navigation technology on the accuracy and duration of endodontic surgery. RESULTS: With dynamic navigation, the root-end resection length deviation was 0.46 ± 0.06 mm, the angle deviation was 2.45 ± 0.96°, and the operation time was 187 ± 22.97 s. Without dynamic navigation, the root-end resection length deviation was 1.20 ± 0.92 mm, the angle deviation was 16.20 ± 9.59°, and the operation time was 247 ± 61.47 s. Less deviation was achieved and less operation time was spent with than without dynamic navigation (P < 0.01). CONCLUSION: The application of a dynamic navigation system in endodontic surgery can improve the accuracy and efficiency significantly for operators without surgical experience and reduce the operation time.


Assuntos
Impressão Tridimensional , Humanos , Projetos Piloto , Técnicas In Vitro , Cirurgia Assistida por Computador/métodos , Apicectomia/métodos , Duração da Cirurgia , Sistemas de Navegação Cirúrgica
16.
Theranostics ; 14(7): 2736-2756, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38773975

RESUMO

Radical prostatectomy (RP) combined with pelvic lymph node dissection (PLND) is the first step in multimodal treatment of prostate cancer (PCa) without distant metastases. For a long time, the surgical resection range has been highly dependent on the surgeon's visualization and experience with preoperative imaging. With the rapid development of prostate-specific membrane antigen positron emission tomography and single-photon emission computed tomography (PSMA-PET and PSMA-SPECT), PSMA-targeted surgery has been introduced for a more accurate pathological diagnosis and complete resection of positive surgical margins (PSMs) and micro-lymph node metastases (LNMs). We reviewed PSMA-targeted surgeries, including PSMA-PET-guided prostatic biopsy (PSMA-TB), PSMA-targeted radio-guided surgery (PSMA-RGS), PSMA-targeted fluorescence-guided surgery (PSMA-FGS), and multi-modality/multi-targeted PSMA-targeted surgery. We also discuss the strengths and challenges of PSMA-targeted surgery, and propose that PSMA-targeted surgery could be a great addition to existing surgery protocols, thereby improving the accuracy and convenience of surgery for primary and recurrent PCa in the near future.


Assuntos
Antígenos de Superfície , Glutamato Carboxipeptidase II , Prostatectomia , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Glutamato Carboxipeptidase II/metabolismo , Antígenos de Superfície/metabolismo , Prostatectomia/métodos , Cirurgia Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Excisão de Linfonodo/métodos
17.
Nano Lett ; 24(20): 6131-6138, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38727077

RESUMO

Accurate intraoperative tumor delineation is critical to achieving successful surgical outcomes. However, conventional techniques typically suffer from poor specificity and low sensitivity and are time-consuming, which greatly affects intraoperative decision-making. Here, we report a cascade activatable near-infrared fluorescent (NIRF) probe IR780SS@CaP that can sequentially respond to tumor acidity and elevated glutathione levels for accurate intraoperative tumor localization. Compared with nonactivatable and single-factor activatable probes, IR780SS@CaP with a cascade strategy can minimize nonspecific activation and false positive signals in a complicated biological environment, affording a superior tumor-to-normal tissue ratio to facilitate the delineation of abdominal metastases. Small metastatic lesions that were less than 1 mm in diameter can be precisely identified by IR780SS@CaP and completely excised under NIRF imaging guidance. This study could benefit tumor diagnosis and image-guided tumor surgery by providing real-time information and reliable decision support, thus reducing the risk of both recurrence and complications to improve patient outcomes.


Assuntos
Corantes Fluorescentes , Corantes Fluorescentes/química , Humanos , Animais , Camundongos , Imagem Óptica/métodos , Linhagem Celular Tumoral , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Cirurgia Assistida por Computador/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos
19.
J Med Invest ; 71(1.2): 174-176, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38735716

RESUMO

BACKGROUND: Augmented reality navigation is the one of the navigation technologies that allows computer-generated virtual images to be projected onto a real-world environment. Augmented reality navigation can be used in spinal tumor surgery. However, it is unknown if there are any pitfalls when using this technique. CASE PRESENTATION: The patient in this report underwent complete resection of a cauda equina tumor at the L2-L3 level using microscope-based augmented reality navigation. Although the registration error of navigation was <1 mm, we found a discrepancy between the augmented reality navigation images and the actual location of the tumor, which we have called "navigation mismatch". This mismatch, which was caused by the mobility of the spinal tumor in the dura mater, seems to be one of the pitfalls of augmented reality navigation for spinal tumors. CONCLUSIONS: Combined use of intraoperative ultrasound and augmented reality navigation seems advisable in such cases. J. Med. Invest. 71 : 174-176, February, 2024.


Assuntos
Realidade Aumentada , Cauda Equina , Humanos , Cauda Equina/diagnóstico por imagem , Cauda Equina/cirurgia , Neoplasias do Sistema Nervoso Periférico/cirurgia , Neoplasias do Sistema Nervoso Periférico/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos , Masculino , Feminino , Pessoa de Meia-Idade
20.
Acta Neurochir (Wien) ; 166(1): 212, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38739282

RESUMO

PURPOSE: Glioblastoma is a malignant and aggressive brain tumour that, although there have been improvements in the first line treatment, there is still no consensus regarding the best standard of care (SOC) upon its inevitable recurrence. There are novel adjuvant therapies that aim to improve local disease control. Nowadays, the association of intraoperative photodynamic therapy (PDT) immediately after a 5-aminolevulinic acid (5-ALA) fluorescence-guided resection (FGR) in malignant gliomas surgery has emerged as a potential and feasible strategy to increase the extent of safe resection and destroy residual tumour in the surgical cavity borders, respectively. OBJECTIVES: To assess the survival rates and safety of the association of intraoperative PDT with 5-ALA FGR, in comparison with a 5-ALA FGR alone, in patients with recurrent glioblastoma. METHODS: This article describes a matched-pair cohort study with two groups of patients submitted to 5-ALA FGR for recurrent glioblastoma. Group 1 was a prospective series of 11 consecutive cases submitted to 5-ALA FGR plus intraoperative PDT; group 2 was a historical series of 11 consecutive cases submitted to 5-ALA FGR alone. Age, sex, Karnofsky performance scale (KPS), 5-ALA post-resection status, T1-contrast-enhanced extent of resection (EOR), previous and post pathology, IDH (Isocitrate dehydrogenase), Ki67, previous and post treatment, brain magnetic resonance imaging (MRI) controls and surgical complications were documented. RESULTS: The Mantel-Cox test showed a significant difference between the survival rates (p = 0.008) of both groups. 4 postoperative complications occurred (36.6%) in each group. As of the last follow-up (January 2024), 7/11 patients in group 1, and 0/11 patients in group 2 were still alive. 6- and 12-months post-treatment, a survival proportion of 71,59% and 57,27% is expected in group 1, versus 45,45% and 9,09% in group 2, respectively. 6 months post-treatment, a progression free survival (PFS) of 61,36% and 18,18% is expected in group 1 and group 2, respectively. CONCLUSION: The association of PDT immediately after 5-ALA FGR for recurrent malignant glioma seems to be associated with better survival without additional or severe morbidity. Despite the need for larger, randomized series, the proposed treatment is a feasible and safe addition to the reoperation.


Assuntos
Ácido Aminolevulínico , Neoplasias Encefálicas , Glioblastoma , Recidiva Local de Neoplasia , Fotoquimioterapia , Cirurgia Assistida por Computador , Humanos , Glioblastoma/cirurgia , Glioblastoma/tratamento farmacológico , Glioblastoma/diagnóstico por imagem , Ácido Aminolevulínico/uso terapêutico , Masculino , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade , Fotoquimioterapia/métodos , Recidiva Local de Neoplasia/cirurgia , Idoso , Estudos de Coortes , Cirurgia Assistida por Computador/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Adulto , Estudos Prospectivos , Procedimentos Neurocirúrgicos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...