Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.311
Filtrar
1.
Open Heart ; 11(1)2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806222

RESUMO

OBJECTIVE: This study aims to compare aortic morphology between repaired coarctation patients and controls, and to identify aortic morphological risk factors for hypertension and cardiovascular events (CVEs) in coarctation patients. METHODS: Repaired coarctation patients with computed tomography angiography (CTA) or magnetic resonance angiography (MRA) were included, followed-up and compared with sex-matched and age-matched controls. Three-dimensional aortic shape was reconstructed using patients' CTA or MRA, or four-dimensional flow cardiovascular magnetic resonance in controls, and advanced geometrical characteristics were calculated and visualised using statistical shape modelling. In patients, we examined the association of geometrical characteristics with (1) baseline hypertension, using multivariable logistic regression; and (2) cardiovascular events (CVE, composite of aortic complications, coronary artery disease, ventricular arrhythmias, heart failure hospitalisation, stroke, transient ischaemic attacks and cardiovascular death), using multivariable Cox regression. The least absolute shrinkage and selection operator (LASSO) method selected the most informative multivariable model. RESULTS: Sixty-five repaired coarctation patients (23 years (IQR 19-38)) were included, of which 44 (68%) patients were hypertensive at baseline. After a median follow-up of 8.7 years (IQR 4.8-15.4), 27 CVEs occurred in 20 patients. Aortic arch dimensions were smaller in patients compared with controls (diameter p<0.001, wall surface area p=0.026, volume p=0.007). Patients had more aortic arch torsion (p<0.001) and a higher curvature (p<0.001). No geometrical characteristics were associated with hypertension. LASSO selected left ventricular mass, male sex, tortuosity and age for the multivariable model. Left ventricular mass (p=0.014) was independently associated with CVE, and aortic tortuosity showed a trend towards significance (p=0.070). CONCLUSION: Repaired coarctation patients have a smaller aortic arch and a more tortuous course of the aorta compared with controls. Besides left ventricular mass index, geometrical features might be of importance in long-term risk assessment in coarctation patients.


Assuntos
Coartação Aórtica , Angiografia por Tomografia Computadorizada , Angiografia por Ressonância Magnética , Humanos , Coartação Aórtica/cirurgia , Coartação Aórtica/complicações , Coartação Aórtica/diagnóstico por imagem , Masculino , Feminino , Angiografia por Tomografia Computadorizada/métodos , Adulto , Fatores de Risco , Adulto Jovem , Seguimentos , Fatores de Tempo , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Medição de Risco/métodos , Resultado do Tratamento , Hipertensão/complicações , Hipertensão/fisiopatologia , Adolescente
2.
Rev Assoc Med Bras (1992) ; 70(5): e20231626, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775513

RESUMO

OBJECTIVE: This study aimed to compare the effectiveness of resection and extended end-to-end anastomosis between neonate and infant patients with coarctation. METHODS: This study was designed retrospectively and included 41 neonate (<30 days) and infant (30 days to 1 year) patients who were operated on using the resection and extended end-to-end anastomosis technique for aortic coarctation. Preoperative aortic annulus diameters and Z scores, all aortic arch diameters and Z scores, the presence of hypoplastic aortic segment, and the presence of prematurity were reviewed in both groups. Subsequently, we investigated whether these parameters were statistically related to the residual gradient in the operation area, whether there was a need for early re-intervention, and what was the incidence of mortality in the early postoperative period. In addition, the aortic arch Z scores of the patients at 6 months postoperatively were examined. RESULTS: While the mean age (p<0.001), body weight (p<0.001), and proximal arch Z score (p=0.029) were found to be significantly lower in the neonate group than in the infant group, the total length of the intensive care unit stay (p=0.013) and the total length of hospital stay (p=0.017) were found to be significantly higher. In addition, significant enlargement was detected in the proximal arch, distal arch, and isthmus segments in both patient groups. CONCLUSION: The resection and extended end-to-end anastomosis is an equally effective technique that can provide a marked decrease in gradient in the coarctation area and a significant enlargement of the aortic arch segments in the early period after coarctation repair in both neonate and infant patients.


Assuntos
Coartação Aórtica , Tempo de Internação , Humanos , Coartação Aórtica/cirurgia , Recém-Nascido , Lactente , Resultado do Tratamento , Estudos Retrospectivos , Feminino , Masculino , Anastomose Cirúrgica/métodos , Aorta Torácica/cirurgia , Fatores Etários
3.
Sci Rep ; 14(1): 11748, 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783056

RESUMO

The present study aimed to evaluate the outcomes of percutaneous treatment of aortic coarctation using self-expandable uncovered Nitinol stents. We conducted a retrospective clinical data review of all patients with aortic coarctation and treated with self-expandable uncovered Nitinol stents at our institution between 2009 and 2019. The gradient pressure across the coarctation site was measured using aortography. Follow-up echocardiography and computed tomography angiography were performed to assess possible stent complications. A total of 127 stents were successfully implanted in 125 patients (64.8% males) with a mean age of 35.36 ± 11.9 years. The gradient across the coarctation site decreased significantly from 67.48 ± 14.79 to 5.04 ± 3.01 mmHg (P < 0.001) after self-expandable stent implantation. Systolic blood pressure (SBP) decreased significantly from 175.53 ± 15.99 to 147.22 ± 12.83 mmHg (P < 0.001) after self-expandable stenting. There were no major technical or clinical complications, including balloon rupture, aneurysmal formation, infection, secondary stent migration, thrombosis, death during the procedure, and in-hospital mortality. On a mean follow-up of 48 ± 23.6 months (12-120 months), the gradient [from 59.43 ± 15.42 to 3.72 ± 1.38 mmHg (P < 0.001)] and SBP [from 175.53 ± 15.99 to 127.99 ± 7.82 mmHg (P < 0.001)] decreased significantly. There was no mortality, aneurysmal formation in the stent site, dislocation, or aortic re-stenosis requiring intervention during mid-term follow-up. Treatment of aortic coarctation using a self-expandable uncovered nitinol stent is safe and effective with promising mid-term outcomes.


Assuntos
Coartação Aórtica , Humanos , Coartação Aórtica/cirurgia , Coartação Aórtica/terapia , Masculino , Feminino , Adulto , Estudos Retrospectivos , Resultado do Tratamento , Pessoa de Meia-Idade , Stents Metálicos Autoexpansíveis/efeitos adversos , Ligas , Stents/efeitos adversos , Angiografia por Tomografia Computadorizada , Adulto Jovem , Seguimentos
5.
Ann Card Anaesth ; 27(1): 82-84, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38722130

RESUMO

ABSTRACT: Paraparesis following cardiac surgery is a manifestation of spinal cord injury (SCI). It can occur in any aortic surgery from the aneurysm to the coarctation of the aorta (CoA) where the cross-clamp of the aorta is applied. Though the incidence of paraplegia is low, its occurrence affects the morbidity and mortality of the patient. There are only sporadic case reports on the development of paraplegia following recurrent and technically challenging repair of CoA. However, the spontaneous development of paraplegia has also been reported in cases of unoperated CoA. The present report describes the case of delayed SCI in which paraparesis developed 5 days post a coarctation repair. The risk factors and strategies to protect the spinal cord during aortic surgeries are emphasized.


Assuntos
Coartação Aórtica , Paraparesia , Complicações Pós-Operatórias , Humanos , Coartação Aórtica/cirurgia , Paraparesia/etiologia , Complicações Pós-Operatórias/etiologia , Masculino , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/etiologia
6.
Kyobu Geka ; 77(5): 345-350, 2024 May.
Artigo em Japonês | MEDLINE | ID: mdl-38720602

RESUMO

Aortic coarctation is diagnosed in approximately 5% of adult patients with congenital heart disease and is commonly diagnosed through the close examination of hypertension. Various surgical strategies for adult coarctation have been recently reported. Generally, aortic replacement may require blood transfusion in case of injury of the well-developed collateral vessels. Therefore, in order to secure an operative safety, we preoperatively used a medical image viewer to identify the abnormal vessels by three-dimensional computer graphics (3DCG) reconstruction. A 34-year-old male patient was referred to our hospital with hypertension and low ankle-brachial pressure index( ABI). Chest computed tomography( CT) scan showed aortic coarctation and development of abnormal collateral vessels. Descending aorta was replaced via a left third-fourth intercostal thoracotomy under partial extracorporeal circulation. As the image viewer depicted, anatomical abnormality of the collateral vessels was identified precisely, and surgically treated without any injury. The patient was discharged 10 days postoperatively without transfusion and with a normalized ABI.


Assuntos
Aorta Torácica , Coartação Aórtica , Imageamento Tridimensional , Humanos , Coartação Aórtica/cirurgia , Coartação Aórtica/diagnóstico por imagem , Masculino , Adulto , Aorta Torácica/cirurgia , Aorta Torácica/diagnóstico por imagem , Tomografia Computadorizada por Raios X
7.
World J Pediatr Congenit Heart Surg ; 15(3): 332-339, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38646823

RESUMO

Objective: Hands-on surgical training (HOST) for congenital heart surgery (CHS), utilizing silicone-molded models created from 3D-printing of patients' imaging data, was shown to improve surgical skills. However, the impact of repetition and frequency of repetition in retaining skills has not been previously investigated. We aimed to longitudinally evaluate the outcome for HOST on two example procedures of different technical difficulties with repeated attempts over a 15-week period. Methods: Five CHS trainees were prospectively recruited. Repair of coarctation of the aorta (CoA) and arterial switch operation (ASO) were selected as example procedures of relatively low and high technical difficulty. Procedural time and technical performance (using procedure-specific assessment tools by the participant, a peer-reviewer, and the proctor) were measured. Results: Coarctation repair performance scores improved after the first repetition but remained unchanged at the follow-up session. Likewise, CoA procedural time showed an early reduction but then remained stable (mean [standard deviation]: 29[14] vs 25[15] vs 23[9] min at 0, 1, and 4 weeks). Conversely, ASO performance scores improved during the first repetitions, but decreased after a longer time delay (>9 weeks). Arterial switch operation procedural time showed modest improvements across simulations but significantly reduced from the first to the last attempt: 119[20] versus 106[28] min at 0 and 15 weeks, P = .049. Conclusions: Complex procedures require multiple HOST repetitions, without excessive time delay to maintain long-term skills improvement. Conversely, a single session may be planned for simple procedures to achieve satisfactory medium-term results. Importantly, a consistent reduction in procedural times was recorded, supporting increased surgical efficiency.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Competência Clínica , Humanos , Estudos Prospectivos , Procedimentos Cirúrgicos Cardíacos/métodos , Modelos Anatômicos , Cardiopatias Congênitas/cirurgia , Silicones , Impressão Tridimensional , Masculino , Feminino , Estudos Longitudinais , Coartação Aórtica/cirurgia , Educação de Pós-Graduação em Medicina/métodos
8.
Braz J Cardiovasc Surg ; 39(3): e20220424, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38629954

RESUMO

OBJECTIVE: To investigate the effect of improving the operative field and postoperative atelectasis of single-lung ventilation (SLV) in the surgical repair of coarctation of the aorta (CoA) in infants without the use of cardiopulmonary bypass (CPB). METHODS: This was a retrospective cohort study. The clinical data of 28 infants (aged 1 to 4 months, weighing between 4.2 and 6 kg) who underwent surgical repair of CoA without CPB from January 2019 to May 2022 were analyzed. Fourteen infants received SLV with a bronchial blocker (Group S), and the other 14 infants received routine endotracheal intubation and bilateral lung ventilation (Group R). RESULTS: In comparison to Group R, Group S exhibited improved exposure of the operative field, a lower postoperative atelectasis score (P<0.001), reduced prevalence of hypoxemia (P=0.01), and shorter durations of operation, mechanical ventilation, and ICU stay (P=0.01, P<0.001, P=0.03). There was no difference in preoperative information or perioperative respiratory and circulatory indicators before SLV, 10 minutes after SLV, and 10 minutes after the end of SLV between the two groups (P>0.05). Intraoperative bleeding, intraoperative positive end-expiratory pressure (PEEP), and systolic pressure gradient across the coarctation after operation were also not different between the two groups (P>0.05). CONCLUSION: This study demonstrates that employing SLV with a bronchial blocker is consistent with enhanced operative field, reduced operation duration, lower prevalence of intraoperative hypoxemia, and fewer postoperative complications during the surgical repair of CoA in infants without the use of CPB.


Assuntos
Coartação Aórtica , Ventilação Monopulmonar , Atelectasia Pulmonar , Lactente , Humanos , Ponte Cardiopulmonar , Coartação Aórtica/cirurgia , Estudos Retrospectivos , Complicações Pós-Operatórias , Hipóxia , Atelectasia Pulmonar/etiologia , Atelectasia Pulmonar/prevenção & controle
10.
Curr Probl Cardiol ; 49(6): 102513, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38556144

RESUMO

BACKGROUND: The authors aim to investigate the clinical implications of stent use for the management of CoA. METHODS: All observational studies on stent implantation for the treatment of aortic coarctation and the relevant RCTs were systematically retrieved. Outcomes included the immediate success rate, pre- and post-stent gradient, survival, minor and major complications, restenosis, post-stent systolic blood pressure, and reintervention rate. The analysis was further stratified by CoA type, stent type, and the mean age of the patients. RESULTS: Our meta-analysis incorporated 66 eligible studies involving 3,880 patients. The success rates for stent placement, defined as achieving post-treatment gradients of ≤20 mmHg and 10 mmHg, 0.96 (95% CI: 0.95 - 0.97; I2 = 59.83%) and 0.92 (95% CI: 0.89 - 0.95, I2 = 77.63%) respectively. The complication rates were quite low, with minor and major complication rates of 0.017 (95% CI: 0.013 - 0.021) and 0.007 (95% CI: 0.005 - 0.009), respectively. Unplanned reinterventions were required at a rate of 0.021 (95% CI: 0.015 - 0.026). At a mean follow-up of 2.9 years, 97% of the patients survived and 28% remained on antihypertensive therapy. While immediate effectiveness was consistent across age groups, complications were more prevalent in patients aged <20 years, and long-term efficacy was lower in those aged >20 years. Encouragingly, in neonates and infants, CoA stenting yielded results comparable to those observed in older children. CONCLUSION: These findings underscore the overall favorable outcomes of stent placement for aortic coarctation, with considerations for age-related variations in complications and long-term efficacy.


Assuntos
Coartação Aórtica , Stents , Coartação Aórtica/cirurgia , Coartação Aórtica/terapia , Humanos , Resultado do Tratamento , Seguimentos , Procedimentos Endovasculares/métodos , Complicações Pós-Operatórias/epidemiologia
11.
Am J Physiol Heart Circ Physiol ; 326(5): H1117-H1123, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38488518

RESUMO

Noncritical aortic coarctation (COA) typically presents beyond early childhood with hypertension. Correction of COA does not ensure a return to normal cardiovascular health, but the mechanisms are poorly understood. Therefore, we developed a porcine COA model to study the secondary cardiovascular changes. Eight male neonatal piglets (4 sham, 4 COA) underwent left posterolateral thoracotomy with descending aorta (DAO) mobilization. COA was created via a 1-cm longitudinal DAO incision with suture closure, plication, and placement and an 8-mm external band. All animals had cardiac catheterization at 6 (11-13 kg), 12 (26-31 kg), and 20 (67-70 kg) wk of age. Aortic luminal diameters were similar along the thoracic aorta, except for the COA region [6.4 mm COA vs. 17.3 mm sham at 20 wk (P < 0.001)]. Collateral flow could be seen as early as 6 wk. COA peak systolic pressure gradient was 20 mmHg at 6 wk and persisted through 20 wk increasing to 40 mmHg with dobutamine. Pulse pressures distal to the COA were diminished at 12 and 20 wk. This model addresses many limitations of prior COA models including neonatal creation at an expected anatomic position with intimal injury and vessel sizes similar to humans.NEW & NOTEWORTHY A neonatal model of aortic coarctation was developed in a porcine model using a readily reproducible method of aortic plication and external wrap placement. This model addresses the limitations of existing models including neonatal stenosis creation, appropriate anatomic location of the stenosis, and intimal injury creation and mimics human somatic growth. Pigs met American Heart Association (AHA) criteria for consideration of intervention, and the stenoses were graded as moderate to severe.


Assuntos
Coartação Aórtica , Hipertensão , Humanos , Pré-Escolar , Recém-Nascido , Masculino , Animais , Suínos , Coartação Aórtica/cirurgia , Constrição Patológica/complicações , Aorta Torácica/cirurgia , Aorta
13.
Pediatr Cardiol ; 45(3): 544-551, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38315219

RESUMO

We previously reported short-term outcomes for stenting of aortic coarctation (CoA) (native or re-coarctation) with newer generation low-profile stents (Valeo, Formula, and Begraft stents) in children under 30 kg. We present here the medium-term outcomes of this procedure. Retrospective review of patients weighing under 30 kg who had percutaneous stent treatments for coarctation between 2012 and 2021 was performed. Clinical and procedural data were collected; 19 patients were included. The median age at the time of procedure was 5.1 [4.1-6.4] years and median weight 21.0 [17.3-22.3] kg. One patient had a history of re-coarctation. Thirteen (68%) patients were on anti-hypertensives pre-procedure. Different types of stents were used (14 Valeo™, 4 Formula® 535, 1 BeGraft), which can all be dilated to 18 mm or larger. One patient required a 9 F sheath, all others required a 7 F sheath. The narrowest diameter in the aorta increased from a median of 3.5 [3.0-4.5] to 9.4 [8.9-9.8] mm, p < 0.001; there was a reduction in the median pressure gradient across the coarctation from 35.0 [30.0-43.0] to 5.0 [0-10.0] mmHg, p < 0.001. There were no intra-procedural complications. Follow-up was for a median of 56.0 [13.0-65.0] months. Five (26%) of patients underwent re-intervention after a median time frame of 40.0 [39.5-52.0] months; four had balloon dilation, one had repeat stent implantation. Five (26%) patients were on anti-hypertensive agent(s) post-intervention. Our single centre experience demonstrates that percutaneous stenting for coarctation of aorta in children under 30 kg, with low-profile stents, had no significant complications during the median follow-up time of 56 months. This study demonstrated that the procedure is safe and effective for short and medium-term therapy in this group of patients with a 26% re-intervention rate. A quarter of patients remained on anti-hypertensive medication post stenting, emphasizing the importance of long-term follow-up.


Assuntos
Coartação Aórtica , Criança , Humanos , Seguimentos , Coartação Aórtica/complicações , Coartação Aórtica/cirurgia , Resultado do Tratamento , Stents/efeitos adversos , Aorta , Anti-Hipertensivos , Estudos Retrospectivos
14.
Braz J Cardiovasc Surg ; 39(1): e20230220, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38315562

RESUMO

INTRODUCTION: Coarctation of the aorta (CoA) is a narrowing of the thoracic aorta that often manifests as discrete stenosis but may be tortuous or in long segment. The study aimed to evaluate pre and post-surgical aspects of pediatric patients submitted to CoA surgical correction and to identify possible predisposing factors for aortic recoarctation. METHODS: Twenty-five patients were divided into groups according to presence (N=8) or absence (N=17) of recoarctation after surgical correction of CoA and evaluated according to clinical-demographic profile, vascular characteristics via computed angiotomography (CAT), and other pathological conditions. RESULTS: Majority of males (64%), ≥ 15 days old (76%), ≥ 2.5 kg (80%). There was similarity between groups with and without recoarctation regarding sex (male: 87% vs. 53%; P=0.277), age (≥ 15 days: 62.5 vs. 82%; P=0.505), and weight (≥ 2.5 kg: 87.5 vs. 76.5; P=0,492). Altered values of aortic root/Valsalva diameter, proximal transverse arch, and distal isthmus, and normal values for aorta prevailed in preoperative CAT. Normal values for the aortic root/Valsalva sinus diameter were observed with and without recoarctation, the same for both groups regarding ascending and descending aorta in postoperative CAT. No significant difference for altered values of proximal transverse arch and alteration in distal isthmus was observed. CONCLUSION: No predictive risk for recoarctation was observed. CTA proved to be important in CoA diagnosis and management, since CoA is mainly related with altered diameter of aortic root/sinus of Valsalva and proximal and distal aortic arch/isthmus, however, it failed to show predictive risk for recoarctation.


Assuntos
Coartação Aórtica , Humanos , Masculino , Criança , Recém-Nascido , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Seguimentos , Angiografia por Tomografia Computadorizada , Aorta/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Estudos Retrospectivos
15.
J Cardiothorac Surg ; 19(1): 71, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326839

RESUMO

BACKGROUND: Supra aortic obstruction in children is uncommon and is seen in certain unique conditions. While intraluminal obstruction due to heavy calcification is seen in older populations, it is not described in pediatric populations. The coral reef aorta is a rare and distinct calcifying disease causing luminal obstruction of the suprarenal aorta in adults. The definition of this diagnosis relies entirely on the unique aspects and consistency of the lesions, which are rock-hard, irregular, gritty plaques with a white luminal surface resembling a coral reef. However, no such case has been described in children. CASE PRESENTATION: We present an adolescent boy who presented with a heavily calcified ascending aortic lesion associated with aortopathy and hypertension, 12 years after an aortic coarctation repair. The investigations included echocardiography, magnetic resonance and computer-tomographic imaging. A 3-D model was printed in order to visualize and plan surgical steps in advance for safe placement of clamps and defining the extent of resection. In addition, it provided an idea about tissue quality, thickness, spatial relationship, and orientation in relation to surrounding structures. Successful resection and replacement of the diseased segment of the aorta were achieved on cardiopulmonary bypass support. Post-operative recovery was uneventful, and at 6-month follow-up, the patient is doing well. In this report, various aspects of such lesions have been discussed, including clinical presentations, complications, planning and conduct of a safe cardiopulmonary bypass, and precautions during surgery for a successful outcome. CONCLUSION: Complicated obstructive aortic lesions in children require careful assessment, appropriate advanced imaging, and the use of 3-D printing technology in order to plan and perform safe and effective surgical management. The etiology of severe calcified aorta in children may be related to metabolic factors, previous surgery, use of a homograft, or an inflammatory process. However, it has yet to be proven.


Assuntos
Coartação Aórtica , Doenças da Aorta , Adolescente , Humanos , Masculino , Aorta Abdominal/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/patologia , Coartação Aórtica/complicações , Coartação Aórtica/diagnóstico , Coartação Aórtica/cirurgia , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico , Doenças da Aorta/cirurgia , Recifes de Corais
16.
Medicine (Baltimore) ; 103(5): e37121, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38306550

RESUMO

This study aims to share the results of critically ill newborn cases with interrupted aortic arch (IAA) and Left ventricular outflow tract (LVOT) obstruction (LVOTO) who underwent the hybrid approach, which consists of bilateral pulmonary artery banding and/or patent ductus arteriosus stenting, as first-line treatment. This retrospective study includes the results of high-risk term newborns whom we applied a hybrid approach due to IAA and LVOTO in our clinic between January 1, 2021 and December 31, 2021. The demographic characteristics, hybrid approach methods and results of the cases were evaluated. Nine cases underwent hybrid approach during the study period. The mean age and weight at interventions were 7 days (3-16 days) and 3280 g (2700-4300 g). Six of the patients were diagnosed with type B IAA, 2 with type A, and one with type C. LVOTO was present in 7 patients. The success rate for the procedures was 100%. No patients died during the procedure or within the first 5 days after the procedure or from reasons related to the procedure. The median length of the hospital stay after stent placement was 28 days (22-35 days) for discharged patients. Three patients died in interstage period, and 6 patients underwent total corrective surgery after a median of 7 months (4-10 months). The average LVOT diameter was increased from 3.1 mm to 4.8 mm before total repair surgery. The hybrid approach should be kept in mind for treating high risk newborns with IAA with LVOTO and high-risk newborns who are not suitable for single stage total corrective surgery.


Assuntos
Coartação Aórtica , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Recém-Nascido , Humanos , Lactente , Aorta Torácica/cirurgia , Estudos Retrospectivos , Obstrução do Fluxo Ventricular Externo/cirurgia , Reoperação , Coartação Aórtica/cirurgia , Resultado do Tratamento
17.
Echocardiography ; 41(1): e15742, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284680

RESUMO

BACKGROUND: The LV myocardial strain and hemodynamic forces (HDFs) are innovative markers of LV function. Aortic coarctation is safely repaired in infancy; however, mortality and morbidity remain increased in later life. The study investigated the role of left ventricular myocardial deformation and HDFs in asymptomatic patients who underwent successful aortic coarctation repair. METHODS: Clinical and echocardiographic data were analyzed from 42 repaired CoA, 32 ± 20 years after surgery, 2D echocardiographic global longitudinal strain (GLS), circumferential strain (GCS) and HDFs were determined. CoA patients were compared with 42 patients affected by blood hypertension and 84 healthy controls; all matched for age and gender. RESULTS: All groups had normal LV ejection fraction (LVEF), dimensions, and volumes. CoA patients showed a significantly higher rate of LV mass indexed (p < .001) and left atrial volumes indexed (p < .001). LV myocardial and endocardial global longitudinal and circumferential strain were decreased in CoA patients (p < .001, p < .001; p = .032 and p < .001, respectively). HDF parameters such as LV longitudinal force, LV systolic longitudinal force and LV impulse (LVim) were uniformly reduced (p = .006, p = .001, and p = .001, respectively). LV myocardial strain and HDF parameter values were independently associated with hospitalization for heart failure on univariable Cox regression analysis. CONCLUSION: Despite preserved LVEF, patients with CoA had lower LV myocardial strain and HDF parameters values, independently associated with hospitalization for heart failure.


Assuntos
Coartação Aórtica , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Adulto , Humanos , Coartação Aórtica/complicações , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Função Ventricular Esquerda , Volume Sistólico , Ecocardiografia/métodos , Hemodinâmica , Insuficiência Cardíaca/complicações
19.
Heart Surg Forum ; 27(1): E068-E075, 2024 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-38286643

RESUMO

OBJECTIVE: To investigate postoperative vascular changes of patients with coarctation of the aorta (CoA). METHODS: Literature review of updated articles was performed in June 2023 through the following databases: PubMed, Web of Science, EMBASE, Crohrane Library, CNKI and Wanfang database. All the case-control studies regarding the postoperative changes of vascular structure and function in patients with CoA were analyzed. RESULTS: A total of 596 articles from the above databases were initially identified, with 10 articles being selected for meta-analysis. The analysis showed that weighted mean difference (WMD) of carotid intima-media thickness (cIMT) was 0.07 (95% CI = 0.01~0.13, p < 0.01) and WMD of flow mediated dilation (FMD) was -4.36 (95% CI = -7.49~-1.24, p < 0.01), respectively. The postoperative cIMT of CoA patients was higher than that of the control group, but the postoperative FMD was lower than that of the control group. CONCLUSIONS: The operation on CoA patients ameliorates anatomical deformity in the vascular structures. However, intima-media thickening and endothelial malfunction remain as the key postoperative issues.


Assuntos
Coartação Aórtica , Espessura Intima-Media Carotídea , Humanos , Coartação Aórtica/cirurgia , Dilatação Patológica , Estudos de Casos e Controles
20.
Eur Heart J Cardiovasc Imaging ; 25(2): 249-256, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37585542

RESUMO

AIMS: Left atrial (LA) dysfunction and atrial fibrillation are also relatively common in adults with coarctation of aorta (COA), and the severity of LA dysfunction is associated with a higher risk of atrial fibrillation in this population. The purpose of this study was to determine whether LA function improved after COA repair (LA reverse remodelling), and the relationship between LA reverse remodelling and atrial fibrillation. METHODS AND RESULTS: Retrospective cohort study of adults undergoing COA repair (2003-20). LA reservoir strain was assessed pre intervention and 12-24 months post intervention, using speckle tracking echocardiography. Incident atrial fibrillation was assessed from COA repair to last follow-up. Of 261 adults who underwent COA repair [age 37 ± 13 years; males 148 (57%)], 124 (47%) and 137 (53%) presented with native vs. recurrent COA, respectively. Of 261 patients, 231 (82%) and 48 (18%) underwent surgical and transcatheter COA repair, respectively. The LA reservoir strain increased from 32 ± 8% (pre intervention) to 39 ± 7% (post intervention), yielding a relative increase of 21 ± 5%. Older age [ß ± standard error (SE) -0.16 ± 0.09 per 5 years, P = 0.02], higher systolic blood pressure (ß ± SE -0.12 ± 0.04 per 5 mmHg, P = 0.005), and higher residual COA mean gradient (ß ± SE -0.17 ± 0.06 per 5 mmHg, P = 0.002) post intervention were associated with less LA reverse remodelling, after adjustment for sex, hypertension diagnosis, and left ventricular indices. LA reverse remodelling (hazard ratio 0.97, 95% confidence interval 0.96-0.98 per 1% increase from pre-intervention LA function, P = 0.006) was associated with a lower risk of atrial fibrillation after adjustment for age, sex, pre-intervention LA reservoir strain, and history of atrial fibrillation. CONCLUSION: COA repair resulted in improved LA function and decreased risk for atrial fibrillation, especially in patients without residual hypertension or significant residual COA gradient.


Assuntos
Coartação Aórtica , Fibrilação Atrial , Hipertensão , Masculino , Adulto , Humanos , Adulto Jovem , Pessoa de Meia-Idade , Prognóstico , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Átrios do Coração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...