RESUMO
Based on the current state of the art regarding molar incisor hypomineralisation (MIH)-affected enamel, bonding systems are expected to play a relevant role on the restorative procedures when required. MIH-affected enamel is often subjected to posteruptive breakdown combined or not with carious lesions, predominantly on molars, and may also affect the aesthetics of anterior teeth. As unbalanced mineral and protein contents occur, understanding these alterations is essential before selecting the most appropriate adhesive systems, while bearing in mind their limitations. In particular, when dentin is involved due to enamel breakdown, the use of functional monomer-based bonding systems present in self-etching and universal systems produce a chemical interaction that enhance the bonding. So far, the overall recommendation relies on placing the margin of the restoration on clinically sound enamel, regardless of the category of the adhesive system.
Assuntos
Colagem Dentária , Humanos , Colagem Dentária/métodos , Hipoplasia do Esmalte Dentário , Cimentos Dentários , Esmalte Dentário/patologia , Restauração Dentária Permanente/métodosRESUMO
OBJECTIVE: The objective of this study was to evaluate the shear bond strength of metal brackets bonded with indirect bonding, under different surface treatment protocols. MATERIAL AND METHODS: 40 bovine teeth were randomly divided into four groups (n = 10), according to the type of surface treatment: G1 = 70% alcohol, G2 = air/water spray, G3 = 100-µm aluminum oxide blasting, G4 = direct boning. After drying, the standard Edgewise central incisor brackets were bonded with light-cured resin. The brackets were moved from the plaster models by means of a transfer tray made with condensation silicone, and bonded to the surface of the enamel with self-curing adhesive. The samples were submitted to shear tests by a universal test machine. Data were analyzed with SPSS 20.0 by the one-way ANOVA test and the Tukey post-test. RESULTS: No statistically significant difference (p=0.174) was observed between the mean forces measured between the group for shear strength values of the groups during the test: G1 (5.33 MPa), G2 (3.52 MPa) and G3 (4.58 MPa). CONCLUSION: The bracket surface treatment protocols presented similarities in shear bond strength test. However, alcohol 70% and oxide blasting presented higher absolute values of resistance than the water group.
Assuntos
Colagem Dentária , Esmalte Dentário , Braquetes Ortodônticos , Resistência ao Cisalhamento , Propriedades de Superfície , Animais , Bovinos , Esmalte Dentário/efeitos dos fármacos , Colagem Dentária/métodos , Óxido de Alumínio/química , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina/química , Etanol , Água/química , Distribuição AleatóriaRESUMO
The aim of this study was to assess the effect of adding arginine at different concentrations to commercial and experimental orthodontic resins on shear bond strength (SBS), as well as on the antimicrobial activity of arginine against S. mutans. Metal brackets were bonded onto the surface of 120 bovine incisors using Transbond, OrthoCem, and an experimental resin (ER), adding 0, 2.5, 5, and 7 wt.% of arginine. The SBS test was performed in deionized water at 37 ºC for 24 h, at 0.5 mm/min. SBS test results were subjected to two-way ANOVA and Tukey's test (α = 0.05). CFU/mL data (antimicrobial assessment) were assessed by Kruskal-Wallis and Dunn's tests (α = 0.05). No statistical difference between the resins was observed in untreated groups (p > 0.05). The addition of arginine at 2.5% (27.7 MPa) and 5% (29.0 MPa) increased the SBS of Transbond when compared (p < 0.05) to OrthoCem (18.5 and 15.6 MPa, respectively) and ER (16.3 and 18.1 MPa, respectively). Arginine at 7% improved the SBS of Transbond (24.1 MPa) and ER (21.0 MPa), which was statistically higher (p < 0.05) than OrthoCem (12.6 MPa). OrthoCem did not show a statistically significant difference at the three concentrations of arginine (p > 0.05). The addition of arginine to resins reduced the count of S. mutans (p < 0.05). As for ER, all concentrations of arginine significantly decreased CFU/mL (p < 0.05). Among commercial resins, only 7% of arginine significantly reduced CFU/mL. The addition of arginine did not interfere with the bond strength and demonstrated antibacterial activity against S. mutans.
Assuntos
Arginina , Teste de Materiais , Braquetes Ortodônticos , Cimentos de Resina , Resistência ao Cisalhamento , Streptococcus mutans , Arginina/química , Arginina/farmacologia , Animais , Bovinos , Streptococcus mutans/efeitos dos fármacos , Análise de Variância , Cimentos de Resina/química , Fatores de Tempo , Reprodutibilidade dos Testes , Propriedades de Superfície/efeitos dos fármacos , Estatísticas não Paramétricas , Valores de Referência , Colagem Dentária/métodos , Bis-Fenol A-Glicidil MetacrilatoRESUMO
Background: Adhesion to zirconia remains a significant dental challenge. This study is aimed at assessing the bond strength of zirconia based on surface treatment with pre or postsintering sandblasting associated with different chemical treatments and resin cements. Methods: Zirconia blocks were divided into 12 experimental groups based on the surface treatment (presintering sandblasting or postsintering sandblasting/tribochemical abrasion treatment), chemical treatment (none, Single Bond Universal, or Signum Zirconia Bond), and choice of cement (Panavia F or RelyX™ U200). The bond strength was measured by shear tests using a universal testing machine. The fracture analysis was performed using stereomicroscopy. Data were analyzed using three-way ANOVA and Tukey's test (α = 5%). Results: Triple and double factor's interactions were not significant (p > 0.05). Regarding the surface treatment factor, the bond strength following postsintering sandblasting treatment associated with tribochemical abrasion (9.15 ± 3.62 MPa) was significantly higher than presintering sandblasting treatment (5.24 ± 3.53 MPa). Concerning the chemical treatment factor, bond strengths were ranked as follows: Signum Zirconia Bond > Single Bond Universal > no treatment. The bond strength of the resin cements did not differ among them. Most fractures (67%) were classified as adhesive, and 32% were categorized as mixed fractures. Conclusion: Surface treatment via postsintering sandblasting combined with tribochemical abrasion demonstrated superior efficacy than in presintering sandblasting. Additionally, chemical treatment with zirconia primer increased the bond strength of zirconia irrespective of the surface physical treatment.
Assuntos
Colagem Dentária , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Zircônio , Zircônio/química , Cimentos de Resina/química , Colagem Dentária/métodos , Resistência ao Cisalhamento , Cimentos Dentários/química , HumanosRESUMO
Background: Over the past decade, 3D printing technology has revolutionized various fields, including dentistry. Provisional restorations play a crucial role in prosthetic rehabilitation, necessitating the evaluation of their bond strength with different provisional cement agents. Aims: This study is aimed at assessing the immediate and long-term bond strength of 3D-printed dental crowns using three provisional cement agents. Materials and Methods: Provisional crowns (N = 36) were manufactured using 3D modeling software and cemented in dentin analogues (G10 Nema resin). After the crowns' fabrication, they were randomly divided into three groups (n = 12) for cementation with Relyx Temp 3M ESPE, Provicol-VOCO, and Meron-VOCO. Tensile strength tests were conducted using a universal testing machine, with half of the specimens subjected to 2000 thermal cycles before testing. Finite element analysis was employed to assess tensile stress distribution. Results: Statistical analysis (two-way ANOVA and Tukey's test at a 95% confidence level) revealed significant effects of cement type (p = 0.006) and thermal aging (p = 0.001) on bond strength. Glass ionomer cement exhibited the highest immediate resistance, while all types of cement were adversely affected by thermal aging, resulting in decreased bond strength. Conclusion: Thermal aging significantly alters the properties of 3D printing resin and affects the bond strength of provisional cement with 3D-printed crowns. Despite the adverse effects of thermal aging, glass ionomer cement demonstrated the highest immediate resistance. Clinicians should carefully consider these findings when selecting provisional cements for 3D-printed crowns.
Assuntos
Coroas , Impressão Tridimensional , Resistência à Tração , Humanos , Teste de Materiais , Análise de Elementos Finitos , Cimentos de Ionômeros de Vidro/química , Cimentos Dentários/química , Colagem Dentária/métodosRESUMO
PURPOSE: This study aimed to assess the impact of battery levels in single-peak and multi-peak light-curing units (LCUs) on irradiance, and their effects on glass fiber post push-out bond strength to root dentin and the degree of conversion of dual-cure universal resin cement. METHODS AND MATERIALS: Sixty bovine roots underwent endodontic treatment and were randomly distributed into 6 groups (n=10), formed by combining two LCUs (single-peak and multipeak) and three battery levels (100%, 50%, and 10%). A spectrophotometer measured irradiance (mW/ cm2) and spectral irradiance (mW/cm2/nm). Push-out bond strength (PBS) tests occurred at three root regions (cervical, middle, and apical), with optical and scanning electron microscopy for failure mode analysis. Degree of conversion (DC) was evaluated across the root regions. Data were analyzed using two-way repeated measures ANOVA and the Tukey HSD test. The Fisher exact test verified failure modes (α=0.05). RESULTS: As multipeak LCU battery levels decreased, emitted irradiance also diminished, with notable PBS reductions in the apical thirds. Failure modes were influenced by different conditions, primarily exhibiting mixed modes. Battery levels significantly impacted DC in the multipeak LCU, particularly in the cervical region, while the single-peak LCU exhibited DC reduction at the 10% battery level in the cervical region. CONCLUSIONS: Emitted irradiance, resin cement DC, and glass fiber post bond strength to root dentin may be influenced by varying cordless LCUs and battery levels.
Assuntos
Lâmpadas de Polimerização Dentária , Vidro , Técnica para Retentor Intrarradicular , Cimentos de Resina , Cimentos de Resina/química , Bovinos , Técnica para Retentor Intrarradicular/instrumentação , Animais , Teste de Materiais , Microscopia Eletrônica de Varredura , Colagem Dentária/métodos , Análise do Estresse Dentário , Cura Luminosa de Adesivos Dentários/métodos , Técnicas In Vitro , DentinaRESUMO
This laboratory study aimed to evaluate the effects of zirconium dioxide (ZrO2) slurry surface treatment on the bond strength of ultratranslucent zirconia to resin cement using different ceramic primers. The surface morphology was evaluated by scanning electron microscopy (SEM) and atomic force microscopy (AFM), and the interface was evaluated by SEM. Additionally, the phase composition was analyzed by X-ray diffraction (XRD). Specimens of zirconia (n=120) were obtained and divided into two groups according to the surface treatment: (1) airborne particle abrasion with 50-µm aluminum oxide (n=60) and (2) ZrO2 slurry (n=60). The 60 specimens were then further divided into three groups (n=20) according to the ceramic primer application: no primer (NP), Monobond N (MB), and Clearfil ceramic primer (CP). Four resin cement cylinders were built on each ceramic specimen. Half of the specimens (n=10) were subjected to a microshear bond strength (µSBS) test after 24 hours of storage in distilled water, and the other half (n=10) were subjected to a µSBS test after thermocycling. Additional specimens were prepared for SEM, AFM, and XRD analyses. According to the Kruskal-Wallis and Student-Newman-Keuls post hoc tests, the µSBS values were significantly higher for MB and CP than for NP (p<0.05), and there were no significant differences in µSBS for both surface treatments associated with MB and CP after 24 hours of storage (p>0.05). Thermocycling significantly decreased the µSBS values for all specimens, especially for the NP groups and ZrO2 slurry treatment groups, and gaps at the interface were observed by SEM. SEM and AFM analyses showed agglomerate-type irregularities on the ceramic surface for ZrO2 slurry treatment. XRD spectra showed that ZrO2 slurry did not cause phase transformation. It was concluded that ZrO2 slurry promoted irregularities on the ultratranslucent zirconia surface, not causing phase transformation; moreover, the values of µSBS were comparable to those of airborne particle abrasion with aluminum oxide. However, neither surface treatment nor ceramic primer prevented the degradation of the interface.
Assuntos
Colagem Dentária , Análise do Estresse Dentário , Microscopia Eletrônica de Varredura , Cimentos de Resina , Propriedades de Superfície , Zircônio , Zircônio/química , Cimentos de Resina/química , Cimentos de Resina/uso terapêutico , Colagem Dentária/métodos , Teste de Materiais , Microscopia de Força Atômica , Difração de Raios X , MetacrilatosRESUMO
INTRODUCTION: To assess the effect of combinations of two different endodontic sealers used in initial and endodontic retreatment on the bond strength of the secondary obturation and the penetrability of the sealers. METHODS: Forty-eight mandibular premolars were used, receiving standardized endodontic access and biomechanical preparation. Twenty-four teeth received AH Plus sealer (AHP) in primary obturation and the others received Bio-C Sealer (BCS). Retreatment protocol was performed with an R50 instrument. The samples were further subdivided into four groups (n = 12) based on the combination of primary/secondary obturation sealers: AHP/AHP; AHP/BCS; BCS/AHP; and BCS/BCS. Four samples from each subgroup received the addition of fluorophores to the sealer for penetrability analysis using laser scanning confocal fluorescence microscopy. The root portion on the 8 push-out samples was sectioned into 6 slices of 1.0 mm. Bond strength (BS) was assessed using a universal testing machine until displacement of the filling mass. Failure pattern was evaluated under a stereomicroscope (20× magnification). BS data were analyzed using two-way analysis of variance followed by Tukey's test (P < .05), and the association between the failure pattern and BS value was assessed using the chi-square test (P < .05). Penetrability was qualitatively evaluated. RESULTS: The highest BS values were observed in the AHP/AHP (4.54 ± 1.5 MPa) and BCS/AHP (5.00 ± 1.0 MPa) groups (P < .05), with a higher percentage of adhesive failures to the filling material for all groups. Laser scanning confocal fluorescence microscopy images indicated greater penetrability of AHP compared to BCS, both in initial treatment and retreatment. CONCLUSION: AHP sealer exhibited higher BS and greater penetrability compared to BCS sealer.
Assuntos
Colagem Dentária , Retratamento , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Humanos , Materiais Restauradores do Canal Radicular/uso terapêutico , Colagem Dentária/métodos , Obturação do Canal Radicular/métodos , Tratamento do Canal Radicular/métodos , Dente Pré-Molar , Resinas Epóxi/uso terapêutico , Análise do Estresse DentárioRESUMO
OBJECTIVE: The aim of this study was to evaluate the effect of an adhesive loaded with 0.2 % copper (Cu) and 5 % zinc oxide (ZnO) nanoparticles (Nps) on its adhesive properties and enzymatic activity at the hybrid layer ex vivo in a randomized clinical model. METHODS: Fifteen patients participated in this study, and a total of 30 third molars were used. Occlusal cavities (4 × 4 × 2 mm) were made in each tooth, and randomly divided into 2 groups: (i) Experimental group: commercial adhesive loaded with 0.2wt % CuNps and 5wt % ZnONps; and (ii) Control Group: non-loaded commercial adhesive. Teeth were restored with resin composite. Thirty days later, extractions were performed. Extracted teeth were longitudinally sectioned. Nps in powder were characterized by field emission scanning electron microscope (FE-SEM) and energy dispersive X-ray (EDX) analysis. Microtensile bond strength (µTBS), degree of conversion (DC), and nanoleakeage (NL) tests were executed. In situ zymography (Zym) was performed to evaluate the gelatinolytic activity at the hybrid layer. Student's t-test (α = 0.05) was applied for all tests. RESULTS: µTBS and DC did not show significant differences (p > 0.05) between both groups. However, NL and gelatinolytic activity at the hybrid layer showed significant values (p < 0.05) for experimental group in comparison with control group. CONCLUSION: The addition of 0.2 % CuNps and 5 % ZnONps to a universal adhesive decreases NL and gelatinolytic activity at the hybrid layer, without jeopardizing its adhesive properties. SIGNIFICANCE: This randomized clinical trial with ex vivo analysis demonstrate that a commercial adhesive modified with 0.2wt % Cu and 5wt % ZnO Nps that does not affect its adhesive properties, reducing gelatinolytic activity and nanoleakage at the hybrid layer, which should contribute to an improvement of long term bonding-dentine clinical performance.
Assuntos
Resinas Compostas , Cobre , Colagem Dentária , Microscopia Eletrônica de Varredura , Resistência à Tração , Óxido de Zinco , Humanos , Óxido de Zinco/química , Cobre/química , Colagem Dentária/métodos , Resinas Compostas/química , Nanopartículas/química , Adesivos Dentinários/química , Dentina/efeitos dos fármacos , Dentina/enzimologia , Teste de Materiais , Masculino , Cimentos de Resina/química , Adulto , Feminino , Propriedades de Superfície , Cimentos Dentários/química , Dente Serotino , Restauração Dentária Permanente/métodos , Espectrometria por Raios XRESUMO
This in vitro study aimed to evaluate the repair bond strength of resin-modified glass ionomer cement using either the same material or a universal adhesive in the etch-and-rinse and self-etch modes plus resin composite. Twenty-four resin-modified glass ionomer cement blocks were stored in distilled water for 14 d and thermocycled. Sandpaper ground specimens were randomly assigned to three experimental groups according to the repair protocol: resin-modified glass ionomer cement (Riva Light Cure, SDI) and universal adhesive (Scotchbond Universal Adhesive, 3M Oral Care) in etch-and-rinse or self-etch modes and nanohybrid resin composite (Z350 XT, 3M Oral Care). After 24 h of water storage, the blocks were sectioned, and bonded sticks were subjected to the microtensile bond strength (µTBS) test. One-way ANOVA and Tukey's test were used to analyze the data. The failure mode was descriptively analyzed. The highest µTBS values were obtained when the resin-modified glass ionomer cement was repaired using the same material (p < 0.01). In addition, the mode of application of the universal adhesive system did not influence the repair bond strength of the resin-modified glass ionomer cement. Adhesive/mixed failures prevailed in all groups. Repair of resin-modified glass ionomers with the same material appears to be the preferred option to improve bond strength.
Assuntos
Resinas Compostas , Colagem Dentária , Cimentos de Ionômeros de Vidro , Teste de Materiais , Cimentos de Resina , Resistência à Tração , Cimentos de Ionômeros de Vidro/química , Resinas Compostas/química , Colagem Dentária/métodos , Cimentos de Resina/química , Fatores de Tempo , Análise de Variância , Propriedades de Superfície , Reprodutibilidade dos Testes , Reparação de Restauração Dentária/métodos , Valores de ReferênciaRESUMO
To evaluate the polymerization shrinkage stress and cuspal strain (CS) generated in an artificial (typodont) and in a natural tooth using different resin composites. Twenty artificial and 20 extracted natural molars were selected. Each tooth was prepared with a 4x4 mm MOD cavity. The natural and typodont teeth were divided into four experimental groups (n=10), according to the resin composite used: Filtek Z100 (3M Oral Care) and Beautifil II LS (Shofu Dental). The cavities were filled using two horizontal increments and the CS (µS) was measured by the strain gauge method. Samples were sectioned into stick-shaped specimens and the bond strength (BS) (MPa) was evaluated using a microtensile BS test. Shrinkage stress and CS were analyzed using 3D finite element analysis. No difference was found between the type of teeth for the CS as shown by the pooled averages: Natural tooth: 541.2 A; Typodont model: 591.4 A. Filtek Z100 CS values were higher than those obtained for Beautifil II LS, regardless of the type of teeth. No statistical difference was found for the BS data. Adhesive failures were more prevalent (79.9%). High shrinkage stress values were observed for Filtek Z100 resin, regardless of tooth type. The CS of typodont teeth showed a shrinkage stress effect, generated during restoration, equivalent to that of natural teeth.
Assuntos
Resinas Compostas , Análise do Estresse Dentário , Análise de Elementos Finitos , Teste de Materiais , Polimerização , Estresse Mecânico , Resistência à Tração , Resinas Compostas/química , Humanos , Valores de Referência , Propriedades de Superfície , Reprodutibilidade dos Testes , Colagem Dentária/métodos , Coroa do DenteRESUMO
OBJECTIVE: To evaluate the effect of four different photoactivation protocols (according to "photoactivated faces" - mesial/distal, cervical/incisal or center - and "photoactivation time" - 6-3 s) of a high-power photo activator (Valo Cordless®-Ultradent) on the shear bond strength (SBS) between metal brackets and dental enamel and on the degree of conversion (DC) of an orthodontic resin. MATERIALS AND METHODS: 40 bovine incisor crowns were randomly assigned to 4 groups (n = 10). The brackets were bonded with Transbond XT® resin using 4 protocols according to the "photoactivation protocol" factor (which was subdivided into photoactivated faces and photoactivation time): V3C = 3 s + center; V6C = 6 s + center; V3M3D = 3 s on mesial + 3 s on distal; V3C3I = 3 s on cervical + 3 s on incisal. All the samples were stored for 4 months (water,37ºC) and then subjected to a SBS test (100KgF,1 mm/min). 40 resin discs were made to evaluate the monomer degree of conversion. Data from the SBS and DC were assessed by One-way ANOVA and Tukey's test (5%). Bond failures were analyzed according to the Adhesive Remnant Index (ARI) and evaluated by the Kruskal-Wallis test (5%). RESULTS: There was a statistically significant difference (p = 0.008) in the One-way ANOVA result for SBS values between all groups, but the protocols showed statistically similar results (p ≥ 0.05-Tukey's tests) concerning the photoactivated faces (V6C, V3M3D and V3C3I) and photoactivation time (V3C and V6C) factors individually. There was no statistically significant difference (p ≥ 0.05) in the One-way ANOVA result for DC values. CONCLUSION: The SBS and DC values will vary depending on the protocol applied. CLINICAL RELEVANCE: It is possible to maintain the bracket fixation quality with the use of a high-power LED photo activator associated with a shorter photoactivation time. However, it is assumed that not all types of protocols that might be applied will provide quality bonding, such as V3C, V3M3D and V3C3I, which may - depending on the SBS and DC values - affect the final treatment time, due to brackets debonding, or increase of possibility of damage to dental enamel during bracket removal. Clinical studies are suggested to confirm the hypotheses of this research.
Assuntos
Colagem Dentária , Esmalte Dentário , Análise do Estresse Dentário , Teste de Materiais , Braquetes Ortodônticos , Distribuição Aleatória , Cimentos de Resina , Resistência ao Cisalhamento , Animais , Bovinos , Colagem Dentária/métodos , Cimentos de Resina/química , Esmalte Dentário/química , Propriedades de Superfície , Técnicas In Vitro , Fatores de Tempo , Coroa do Dente , PolimerizaçãoRESUMO
OBJECTIVE: To evaluate the in vitro influence of prior silane application on the microshear bond strength (µSBS) of Scotchbond Universal Plus to glass ceramic. MATERIALS AND METHODS: Thirty blocks of lithium disilicate ceramic were etched with hydrofluoric acid for 20 s and distributed into Group 1 (no silane and no adhesive), Group 2 (adhesive), Group 3 (silane + adhesive). Three cylinders of resin cement were made on each ceramic block. Five blocks (n = 15 cylinders) were subjected to the µSBS test after 24 h, and the other five blocks (n = 15 cylinders) were tested after 6 months of water storage. RESULTS: According to two-way ANOVA, followed by Tukey's test, the means of µSBS (MPa), denoted by different letters, show significant differences (p < 0.05): after 24 h-Group 1 (31.7)B, Group 2 (43.3)A, and Group 3 (31.3)B; after 6 months-Group 1 (14.8)B, Group 2 (33.6)A, and Group 3 (30.3)A. After 6 months of storage, there was a significant decrease in µSBS for Groups 1 and 2, along with an increase in adhesive failures across all groups. CONCLUSIONS: Prior application of silane did not increase the µSBS between Scotchbond Universal Plus and ceramic, and there was degradation at the bond interface over time. CLINICAL SIGNIFICANCE: Prior application of a silane agent is not necessary when using Scotchbond Universal Plus for bonding to glass ceramics. Regardless of the prior application of silane, there is degradation at the bond interface over time.
Assuntos
Cerâmica , Silanos , Silanos/química , Cerâmica/química , Cimentos Dentários , Colagem Dentária/métodos , Cimentos de Resina/químicaRESUMO
This study evaluated the influence of hydrofluoric acid (HF) concentration and thermal cycling on the microshear bond strength (µSBS) of a resin luting agent to IPS e.max® CAD and Rosetta® SM. Ceramic specimens (12.0 x 14.0 x 1.5mm) were randomized into 8 groups (n=10) according to HF concentration, commercial brand, and aging. Immediately after polishing, and etching, all specimens were silanized and a layer of adhesive was applied. A PVS mold of 3 mm thickness and 10mm diameter with (four) 1.0mm holes was fabricated, placed on each specimen, and then filled with a resin luting agent. Half of the specimens were subjected to the µSBS test using an Instron at a speed of 1.0 mm/min, following a 24-hour storage in deionized water at 37ºC. The remaining specimens were subjected to thermal cycling (5ºC-55ºC, 30 seconds per bath) and µSBS. The data were evaluated utilizing a three-way ANOVA and Tukey's post-hoc test (α=0.05). Significant differences were found for HF concentration and aging (p<0.0001). No significant difference in µSBS was found for commercial brands (p=0.085). The interaction between brand and HF concentration (p=0.358), brand and aging (p=0.135), and HF concentration and aging (p=0.138) were not statistically significant. The triple interaction among these factors was not statistically significant (p=0.610). In conclusion, the bond strength is affected by the HF concentration. No statistical difference was observed between the two ceramics. Thermal cycling significantly reduced µSBS.
Assuntos
Cerâmica , Colagem Dentária , Ácido Fluorídrico , Cimentos de Resina , Ácido Fluorídrico/química , Cimentos de Resina/química , Cerâmica/química , Teste de Materiais , Análise do Estresse DentárioRESUMO
This study aimed to evaluate the bond strength between relined fiberglass posts with different composite resin opacities in different thirds of the intraradicular dentin. Thirty single-rooted premolars were endodontically treated and divided into three groups (n=10): fiberglass posts relined with translucent composite resin, fiberglass posts relined with opaque composite resin, and fiberglass posts without relining. After cementation of the posts, the specimens were cut perpendicular to the long axis of the tooth in slices of approximately 1.3 mm of each third to be analyzed (cervical, middle, and apical) and then subjected to the push-out test. The bond strength (MPa) data were subjected to Shapiro-Wilk normality tests and two-way repeated measures analysis of variance, considering the experimental groups and different regions as study factors. Tukey's post-hoc test (p<.05) was applied for comparisons between the groups. In the cervical third, higher values of bond strength were found for the group relined with translucent resin, with a statistically significant difference for the other groups. In the other regions, both opaque and translucent resins showed similar results, but both showed higher values of bond strength compared to fiberglass posts without relining. The bond strength of fiberglass posts to different thirds of intraradicular dentin is influenced by composite resin relining as well as the opacity of the resin. The use of translucent composite resin is a more effective alternative for fiberglass posts relining.
Assuntos
Resinas Compostas , Colagem Dentária , Dentina , Vidro , Técnica para Retentor Intrarradicular , Humanos , Resinas Compostas/química , Colagem Dentária/métodos , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície , Materiais Dentários/química , Dente não VitalRESUMO
To assess the effect of cleaning protocols on dentin contaminated with blood in reparative endodontic materials, bovine root samples were divided: no contamination (N); contamination (P); contamination and cleaning with saline (S), 2.5% NaOCl+saline (Na) or 2.5% NaOCl+17% EDTA+saline (NaE) and filled with: mineral trioxide aggregate (MTA), calcium-aluminate-cement (C), or C+collagen (Ccol) (n=13). The samples were evaluated for porosity, chemical composition, and bond strength. MTA porosity was lower than C (p=0.02) and higher than Ccol (p<0.001). P and NaE were similar (p=1.00), but higher than the other groups (p<0.001). MTA bond strength was similar to Ccol (p=0.777) and lower than C (p=0.028). P presented lower bond strength than the N (p<0.001); S and Na were similar to each other (p=0.969), but higher than P and lower than N (p<0.001). It was observed a predominance of mixed and cohesive failures. None of the samples showed Ca/P ratio values similar to human hydroxyapatite. This study showed that contamination with blood increased the materials porosity, but dentin cleaning with 2.5% NaOCl reduced this effect, and the collagen additive reduced the material porosity. Furthermore, blood contamination reduced the materials bond strength, and cleaning with saline or 2.5% NaOCl diminished this effect.
Assuntos
Sangue , Colágeno , Dentina , Porosidade , Bovinos , Dentina/efeitos dos fármacos , Colágeno/química , Animais , Raiz Dentária/química , Silicatos/química , Compostos de Cálcio/química , Colagem Dentária/métodos , Compostos de Alumínio/química , Cerâmica/química , Teste de Materiais , Materiais Biocompatíveis/química , Óxidos/química , Materiais Restauradores do Canal Radicular/química , Combinação de Medicamentos , Hipoclorito de Sódio/químicaRESUMO
OBJECTIVE: This study aimed to clinically compare the accuracy of bracket positioning between three-dimensionally (3D) printed indirect bonding trays and vacuum-formed trays made over 3D-printed models. MATERIAL AND METHODS: Fourteen patients, planned for fixed orthodontic therapy, were randomly divided into two equal groups. For both groups, both dental arches were scanned, to acquire virtual models, brackets were virtually positioned from central incisors to second premolars, and scans for the final bracket positions were performed. In the first group, transfer trays were 3D-printed. In the second group, virtual models were 3D-printed, and vacuum-formed soft sheets were thermoformed on the printed model. Teeth were indirectly bonded and then scanned. Superimposition of the virtual and the final bracket positioning scans was performed to measure linear and angular deviations in brackets positions. RESULTS: The first group showed significantly less occlusogingival and buccolingual linear errors than the second group. No significant differences in angular deviations were found between both groups. The frequencies of clinically acceptable linear errors within 0.5 mm and angular errors within 2° showed no statistically significant difference between both groups (p> 0.05 for all measurements). The transfer errors in both groups showed linear directional biases toward the mesial, gingival and labial directions. There was no statistically significant difference in the rate of immediate debonding between both groups (10.7% and 7.1% for the first and the second groups, respectively, p=0.295). CONCLUSIONS: 3D-printed indirect bonding trays were more accurate than vacuum-formed trays, in terms of linear deviations. Both types of trays showed similar angular control.
Assuntos
Colagem Dentária , Braquetes Ortodônticos , Impressão Tridimensional , Humanos , Colagem Dentária/métodos , Modelos Dentários , Feminino , Vácuo , Masculino , Adolescente , Adulto Jovem , Dente Pré-Molar/diagnóstico por imagemRESUMO
Objective: To evaluate the enamel bonding ability and orthodontic adhesive resin degree of conversion using the experimental bracket design. Material and Methods. Thirteen bovine teeth were used in the study. The experimental bracket was modified with a translucent region in the center of its body. After enamel etching, Orthocem orthodontic adhesive (FGM, Joinville, Brazil) was applied on the bracket base for bonding. The groups were divided as follows (n = 10 per group): (1) control (CB) with standard brackets and (2) spot bracket (SB) with experimental brackets featuring a 0.8 mm translucent region at the center using carbide bur. Shear bond strength (SBS) was evaluated after 24 hours in a universal testing machine and adhesive remnant index (ARI). The degree of conversion (DC) was analyzed using Raman spectroscopy (n = 3 per group). Data were then analyzed using Student's t-test and Mann-Whitney statistical methods. Results: The SB group exhibited a higher mean SBS (10.33 MPa) compared to the CB Group (8.77 MPa). However, there was no statistical difference between the groups (p = 0.376). Both SB and CB groups had a mean ARI score of 1. Raman analysis revealed a higher degree of conversion in the SB group (49.3%) compared to the CB group (25.9%). Conclusions: The experimental support showed a higher degree of adhesive conversion, although there was no significant increase in bond strength.
Assuntos
Resinas Compostas , Colagem Dentária , Esmalte Dentário , Braquetes Ortodônticos , Polimerização , Resistência ao Cisalhamento , Animais , Bovinos , Colagem Dentária/métodos , Esmalte Dentário/química , Resinas Compostas/química , Teste de Materiais , Cimentos Dentários/química , Cimentos de Resina/químicaRESUMO
OBJECTIVE: This study aimed to evaluate the effect of ultrasonic activation of etch-and-rinse and self-etch adhesive systems on the bond strength of resin cement to irradiated root dentin. MATERIALS AND METHODS: Eighty human maxillary anterior teeth were distributed into 8 groups (n = 10), according to the type of adhesive system used (etch-and-rinse and self-etch), the ultrasonic activation of the adhesive systems, and the dentin condition (irradiated or non-irradiated - 70 Gy). Endodontic treatment was performed followed by fiberglass post-space preparation. After fiberglass posts' luting, the roots were transversely sectioned on dentin discs and submitted to the push-out bond strength test (0.5 mm/min). The fractured specimens were analyzed under a stereomicroscope and Scanning Electron Microscope (SEM) for failure mode classification. One of the dentin discs was analyzed under SEM to evaluate the characteristics of the adhesive interface. RESULTS: Irradiated specimens had lower bond strength than non-irradiated specimens (P < 0.0001). Ultrasonic activation of both adhesive systems increased the bond strength of the resin cement to irradiated dentin (P < 0.0001). Radiotherapy significantly affected the failure mode in the middle (P = 0.024) and apical thirds (P = 0.032) (adhesive failure). CONCLUSION: Non-irradiated specimens had a more homogeneous adhesive interface. When ultrasonically activated, both adhesive systems showed a greater number of resinous tags, regardless of the dentin condition. CLINICAL RELEVANCE: Ultrasonic activation of adhesive systems is a feasible strategy to enhance fiberglass posts retention in oncological patients.
Assuntos
Colagem Dentária , Dentina , Teste de Materiais , Microscopia Eletrônica de Varredura , Técnica para Retentor Intrarradicular , Cimentos de Resina , Humanos , Cimentos de Resina/química , Colagem Dentária/métodos , Dentina/efeitos da radiação , Técnicas In Vitro , Adesivos Dentinários/química , Análise do Estresse Dentário , Propriedades de Superfície , Raiz Dentária/efeitos da radiação , Ultrassom , Condicionamento Ácido do Dente , Incisivo , Vidro/químicaRESUMO
This study evaluated bond strength of glass fiber posts to root dentin using push-out (PO) and diametral compression (DC), testing glycolic acid as a conditioner and varying dentin moisture. An additional aim was to test whether DC can be an alternative test to PO for bond strength assessment. Eighty bovine teeth were divided into eight groups (n = 10) defined by the use of either 37% glycolic acid or 37% phosphoric acid (PA) on moist or wet dentin before bonding with either Adapter SingleBond/RelyX ARC or One Step Plus/Duo-Link Bisco. Each tooth provided discs with an internal diameter of 2 mm, external diameter of 5 mm, and height of 2 mm, which underwent PO and DC. Finite element analysis (FEA) was carried out on 3D models. When analyzing PO results through linear regression, the highest values of bond strength were observed using glycolic acid on wet dentin in the cervical and middle thirds of the teeth. Analyzing DC results, the only statistical influence on values was the dental thirds. The scatterplot of the DC results and the PO bond strength values indicated no relationship between the results of the two tests (r = 0.03; p = 0.64). PO test detected more sensitive changes in bond strength values than DC.