Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transfusion ; 61(1): 191-201, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33107611

RESUMO

BACKGROUND: We previously reported a flow path-ultraviolet C (UVC) irradiation system for platelet concentrates (PCs) with platelet additive solution (PAS) to minimize contamination by bacteria. Here, we investigated functionalities of irradiated platelets (PLTs) in in vitro thrombus formation and in vivo hemostasis. STUDY DESIGN AND METHODS: PAS-PCs were irradiated with flash UVC using the flow path system. Their variables (PLT count, mean platelet volume, pH, glucose, lactate, glycoprotein [GP] Ib, and activated integrin αIIbß3) were evaluated. Static adhesion to collagen or fibrinogen was analyzed using fluorescent microscopy. Thrombus formation under flow conditions was assessed using a collagen-coated bead column. Adenosine diphosphate (ADP)-induced Akt phosphorylation was determined by western blot. In vivo hemostasis and circulatory survival of PLTs were assessed with a rabbit bleeding model. RESULTS: All variables, except for GPIb expression, were slightly, but significantly, impaired after flash UVC irradiation throughout the 6-day storage period. No difference was observed in static adhesion to either collagen or fibrinogen between irradiated and nonirradiated PAS-PCs. In vitro thrombus formation of flash UVC-irradiated PAS-PCs was significantly greater than that of nonirradiated PAS-PCs. ADP-induced Akt phosphorylation was enhanced in irradiated PAS-PCs. In vivo hemostatic efficacy was comparable between the groups on Day 1. The efficacy declined in nonirradiated PAS-PCs on Day 5, while it was retained in flash UVC-irradiated PAS-PCs. Circulatory survival of PLTs was lower in irradiated PAS-PCs. CONCLUSIONS: PAS-PCs irradiated with UVC from xenon flash have favorable properties to achieve hemostasis compared with nonirradiated PAS-PCs.


Assuntos
Plaquetas/metabolismo , Hemostasia/fisiologia , Trombose/metabolismo , Raios Ultravioleta/efeitos adversos , Xenônio/efeitos adversos , Difosfato de Adenosina/metabolismo , Animais , Bactérias/efeitos da radiação , Plaquetas/efeitos da radiação , Colágeno/metabolismo , Colágeno/efeitos da radiação , Fibrinogênio/metabolismo , Fibrinogênio/efeitos da radiação , Hemostasia/efeitos da radiação , Humanos , Masculino , Volume Plaquetário Médio/estatística & dados numéricos , Microscopia de Fluorescência/métodos , Modelos Animais , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/metabolismo , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/efeitos da radiação , Complexo Glicoproteico GPIb-IX de Plaquetas/metabolismo , Complexo Glicoproteico GPIb-IX de Plaquetas/efeitos da radiação , Plaquetoferese/métodos , Coelhos , Xenônio/efeitos da radiação
2.
Vox Sang ; 101(1): 35-43, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21175668

RESUMO

BACKGROUND: A novel short-wave ultraviolet light (UVC) pathogen reduction technology (THERAFLEX UV-Platelets; MacoPharma, Mouvaux, France) without the need of any additional photoactive reagent has recently been evaluated for various bacteria and virus infectivity assays. The use of UVC alone has on the one hand been shown to reduce pathogens but may, on the other hand, have some impact on the platelet (PLT) quality. The purpose of this study was to determine the potential effects on PLT quality of pathogen inactivation treatment using the novel UVC method for PLT concentrates. STUDY DESIGN AND METHODS: Buffy-coat-derived PLTs suspended in SSP+ were irradiated with UVC light in plastic bags (MacoPharma) made of ethyl vinyl acetate, considered to be highly permeable to UVC light. The UVC-treated (test, n=8) as well as the untreated (reference, n=8) PLT units were stored in PLT storage bags composed of n-butyryl, tri n-hexyl citrate-plasticized polyvinyl chloride (MacoPharma) on a flat bed agitator for in vitro testing during 7 days of storage. RESULTS: No significant difference in PLT counts and lactate dehydrogenase between the groups was detected. During storage, glucose decreased more and lactate increased more in the test units. Statistically significant differences were found for glucose (P<0·01) and lactate (P<0·05) on day 7. ATP levels were higher (P<0·01 from day 5) in the reference units. With exception of day 7 (P<0·01 reference vs. test), hypotonic shock response reactivity was not different between groups. Extent of shape change was lower (P<0·01), and CD62P (P<0·05 day 5) was higher in the test units. CD42b and CD41/61 showed similar trends throughout storage, without any significant difference between the units. pH was maintained at >6·8 (day 7) and swirling remained at the highest level (score = 2) for all units throughout storage. CONCLUSION: Our results suggest that irradiation with UVC light has a slight impact on PLT in vitro quality and appears to be insignificant with regard to current in vitro standards.


Assuntos
Trifosfato de Adenosina/metabolismo , Plaquetas/metabolismo , Plaquetas/efeitos da radiação , Preservação de Sangue/métodos , Glucose/metabolismo , Ácido Láctico/metabolismo , Raios Ultravioleta , Trifosfato de Adenosina/efeitos da radiação , Bactérias/crescimento & desenvolvimento , Bactérias/efeitos da radiação , Plaquetas/microbiologia , Glucose/efeitos da radiação , Humanos , Integrina beta3/metabolismo , Integrina beta3/efeitos da radiação , L-Lactato Desidrogenase/metabolismo , L-Lactato Desidrogenase/efeitos da radiação , Ácido Láctico/efeitos da radiação , Selectina-P/metabolismo , Selectina-P/efeitos da radiação , Contagem de Plaquetas , Complexo Glicoproteico GPIb-IX de Plaquetas/metabolismo , Complexo Glicoproteico GPIb-IX de Plaquetas/efeitos da radiação , Glicoproteína IIb da Membrana de Plaquetas/metabolismo , Glicoproteína IIb da Membrana de Plaquetas/efeitos da radiação
3.
Transfusion ; 45(6): 911-9, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15934989

RESUMO

BACKGROUND: Several strategies are being developed to reduce the risk of pathogen transmission associated with platelet (PLT) transfusion. STUDY DESIGN AND METHODS: The impact of a new technology for pathogen reduction based on riboflavin plus illumination (Mirasol PRT, Navigant Biotechnologies, Inc.) at 6.2 and 12.3 J per mL on functional and biochemical characteristics of PLTs was evaluated. PLT concentrates (PCs) obtained by apheresis were treated with Mirasol PRT and stored at 22 degrees C. Modifications in major PLT glycoproteins (GPIbalpha, GPIV, and GPIIb-IIIa), adhesive ligands (von Willebrand factor [VWF], fibrinogen [Fg], and fibronectin), activation antigens (P-selectin and LIMP), and apoptotic markers (annexin V binding and factor [F]Va) were analyzed by flow cytometry. Adhesive and cohesive PLT functions were evaluated with well-established perfusion models. Studies were performed on the preparation day (Day 0) and during PCs storage (Days 3 and 5). RESULTS: Levels of glycoproteins remained stable during storage in PCs treated with 6.2 J per mL pathogen reduction technology (PRT) and similar to those observed in nontreated PCs. When 12.3 J per mL PRT was applied, however, levels of GPIbalpha moderately decreased on Days 3 and 5. VWF, Fg, and FVa were not modified in their expression levels, either by treatment or by storage period. Fibronectin appeared more elevated in all PRT samples. A progressive increase in P-selectin and LIMP expression and in annexin V binding was observed during storage of PRT-treated PCs. Functional studies indicated that 6.2 J per mL Mirasol PRT-treated PLTs preserved adhesive and cohesive functions to levels compatible with those observed in the respective control PCs. CONCLUSION: PLT function was well preserved in PCs treated with 6.2 J per mL Mirasol PRT and stored for 5 days.


Assuntos
Plaquetas , Plaquetas/efeitos dos fármacos , Plaquetas/efeitos da radiação , Preservação de Sangue , Riboflavina/farmacologia , Raios Ultravioleta , Anexina A5/análise , Anexina A5/efeitos dos fármacos , Anexina A5/efeitos da radiação , Antígenos CD/análise , Antígenos CD/efeitos dos fármacos , Antígenos CD/efeitos da radiação , Plaquetas/química , Plaquetas/citologia , Plaquetas/fisiologia , Fibrinogênio/análise , Fibrinogênio/efeitos dos fármacos , Fibrinogênio/efeitos da radiação , Fibronectinas/análise , Fibronectinas/efeitos dos fármacos , Fibronectinas/efeitos da radiação , Citometria de Fluxo , Humanos , Proteínas de Membrana Lisossomal , Selectina-P/análise , Selectina-P/efeitos dos fármacos , Selectina-P/efeitos da radiação , Ativação Plaquetária/efeitos dos fármacos , Ativação Plaquetária/efeitos da radiação , Adesividade Plaquetária/efeitos dos fármacos , Adesividade Plaquetária/efeitos da radiação , Contagem de Plaquetas , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/análise , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/efeitos dos fármacos , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/efeitos da radiação , Complexo Glicoproteico GPIb-IX de Plaquetas/análise , Complexo Glicoproteico GPIb-IX de Plaquetas/efeitos dos fármacos , Complexo Glicoproteico GPIb-IX de Plaquetas/efeitos da radiação , Glicoproteína IIb da Membrana de Plaquetas/análise , Glicoproteína IIb da Membrana de Plaquetas/efeitos dos fármacos , Glicoproteína IIb da Membrana de Plaquetas/efeitos da radiação , Transfusão de Plaquetas , Plaquetoferese , Temperatura , Fatores de Tempo , Fator de von Willebrand/análise , Fator de von Willebrand/efeitos dos fármacos , Fator de von Willebrand/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...